Plans (487) LEGEND -� INV INVERTER&DC DISCONNECT BLUE RAVEN : SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUE RAVEN SO LAR.COM n129'-3" M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE 9450 Southwest Mountain View C COMBINER BOX RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE Lane SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF FRONT OF HOME /� BLUERAVENSOLAR LLC. �� /i FIRE SETBACK N EMT CONDUIT RUN w Iiidam' 0 ® (TO BE DETERMINED IN FIELD) o Z d- 0H O eco O0 PV WIRE STRING Q 0 ' Et W c~2 E-- 16 1.-- U 160e-4n II 00 O PROPERTY LINE OMO s co 0 O CO 0 SCALE: 3/64"= 1'-0" 0' 21' c2' 64 12&' N O ra. o LL MP2 RR 0 0 0 AZIMUTH:278° J—�P —o 0 0 0 CD CD PITCH:26° 2— CD TSRF:72% O m I01 o 140'-5" it d JB a) LI It II IIIIC ilk I I Z . 0 co N o a' Q rn N MP1 2 _ AZIMUTH:188° ° a> w PITCH:26° O� c o O F- F- a Z TSRF:77% — • c -d > til >, o I_ o '4 cm 0 °cry° AC DISCONNECT TO BE LOCATED -- = c) ~ 0 C4 WITHIN 10' OF UTILITY METER DRAWING BY ROOF ATTACHMENTS SHALL BE SPACED Eric Thomas NO GREATER THAN 24"ON CENTER IN ANY DIRECTION WHERE LOCATED DATE WITHIN 3' OFA ROOF EDGE, HIP, EAVE, July 31, 2018 OR RIDGE OSSC 3111.5.3 ITEM 3.35 , „ PROJECT NUMBER 123-8 DC SYSTEM SIZE: 6.38 kW DC 53156741 ROOF TYPE: Comp Shingle SHEET NAME (22) Sunmodule Plus SW 290M Black PROPERTY PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 0 LEGEND FRONT OF HOME NINV INVERTER&DC DISCONNECTBLUE RAVEN 11111 SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF Fa JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT 1_2 BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE U C COMBINER BOX RECIPIENTS ORGANIZATION; Q EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF 0 BLUERAVENSOLAR LLC. r/, FIRE SETBACK EMT CONDUIT RUN c (TO BE DETERMINED IN FIELD) 0 Z ci- O O < co o - Al O PV WIRE STRING < 0 d CC w C+') MP2 I 21— Zu- o AZIMUTH:278° 1 PROPERTY LINE W 0 M 0 m 0 PITCH:26° TSRF:72% O SCALE: yrs°= -0' 0 O0 2 4 8 16 Ct n 1 n n c ❑ 12" — co a) n ❑ 11 z as 1= F., O O tV w Efc Efc Q 2 0-) N °' O (A c ERC J13 — 11 co - >- > W >, o 45 co ~ o o U m AC DISCONNECT TO BE LOCATED Iffc ffc � I rn F 0 m WITHIN 10' OF UTILITY METER ROOF ATTACHMENTS SHALL BE SPACED Ic ffc O DRAWING BY NO GREATER THAN 24"ON CENTER IN Eric Thomas ANY DIRECTION WHERE LOCATED at WITHIN 3' OF A ROOF EDGE, HIP, EAVE, [ffc c DaTE July 31, 2018 OR RIDGE OSSC 3111.5.3 ITEM 3.35 PROJECT NUMBER DC SYSTEM SIZE: 6.38 kW DC MP1 53156741 ROOF TYPE: Comp Shingle AZIMUTH:188° SHEET NAME PITCH:26° SITE PLAN (22) Sunmodule Plus SW 290M Black TSRF:77% Enphase IQ7-60-2-US,----I NVE RTER PAGE NUMBER REVISION PV3 0 PV ARRAY STRUCTURAL CRITERIA ‘er PV MODULE COUNT: 22 MODULES PV MODULE(BEHIND TRIM RAIL) Unirac Sunframe Microrail TRIM RAIL # OF ATTACHMENT POINTS: 60 BLUE AVE N ARRAY AREA: Module Count X 17.51ft2= 385.2ft2 \\\ ROOF AREA: 3860.7ft2 jr X_1'-11" i N N N 1 N 1220S.630E STE.430 48" MAX." AMERICAN FORK,UT 84003 % OF ARRAY/ROOF: 10.0% MAX. 800-377-4480 ARRAY WEIGHT: Module Count x 50Ibs = I100.0Ibs ARRAY DETAIL, FRONT VIEW WWW.BLUERAVENSOLAR.COM DISTRIBUTED LOAD: Array Weight_Array Area=2.86 lbs/ft2 ROOF TYPE: Comp Shingle Scale: 3/8" - I-0" CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE ROOF FRAMING TYPE: Rafter USED FOR THE BENEFIT OF POINT LOAD: Array Weight_Attachments= 18.3Ibs/attachment Unirac Sunframe Microrail FRAME ANYONE EXCEPT RAFTER OR TOP CHORD SIZE: 2x6 BLUERAVENSOLAR NOR SHALL IT RAFTER OR TOP CHORD SPACING: 24"O.C. BE DISCLOSED IN WHOLE OR IN ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C CEILING JOIST OR BOTTOM CHORD SIZE: 2x6 PART TO OTHERS OUTSIDE SITE CRITERIA RECIPIENTS ORGANIZATION, CEILING JOIST OR BOTTOM CHORD SPACING: 24"O.C. EXCEPT IN CONNEC TION WITH THE GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D -. SALE AND USE OF THE RESPECTIVE SFM Raised Seal Flashing , EQUIPMENT.WITHOUT THE WRITTEN PERMISSION OF Unirac Sunframe Microrail BLUERAVENSOLAR LLC. UNIRAC TRIMRAIL //t' W Z FD L O 00 Sunmodule Plus SW 290M Black ./"/ MODULE 26" O I _ _ PV MODULE / WIDTH LL Z D 0) Q 0 .............. O / o � � QO `r CtW � Q _ I: (E)ROOF M Z H o } 11� :: I MEMBRANE U O O 1 `� ARRAY DETAIL, SIDE VIEW w 0 0 m O ii — O _ 2.5 r 1111111111111111 UNIRAC SLIDERS AND --� h- i� TRIMRAIL ROOF ATTACHMENTS Scale: 3/8" = -0" Tc ~O 11 m 2.5"MIN. EMBE-7.1 ED FLASHING Ct CL J u) W 5/16"STAINLESS STEEL LAG BOLT N p WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER Cg (E)BUILDING CTS �_ STRUCTURE - > Z (13 O H Unirac Sunframe Microrail {N 2 — a) c ct o O 2 0' O L O -� _c c w O Sunmodule Plus SW 290M Black z o O i) 0 z . PV MODULE JY I— ` >,W '4 O co �- . f/) I a) 1— CI cfl O• -� �,y (E)ROOF DRAWING BY W IMO 2.5" MEMBRANE Eric Thomas J o ui II —coUNIRAC SLIDERS DATE July 31, 2018 8 2.5" MIN. EMBED.r' H = FLASHING PROJECT NUMBER w 53156741 5/16"STAINLESS STEEL LAG BOLT = WITH 2-1/2"MIN. EMBEDMENT SHEET NAME AND FLAT WASHER EQUIP. DETAIL (E)BUILDING STRUCTURE PAGE NUMBER REVISION PV4 0 BLUE RAVEN 2'-8" 23'-9" - 23'-9" 2'_8„ 1220 S.630E ESTI 430 AMERICAN FORK,UT 84003 800-377-4480 WWW.BLUERAVENSOLAR COM CONFIDENTIAL-THE INFORMATION 0 STRUCTURAL SIDE VIEW HEREIN CONTAINED SHALL NOT BE sale.ss r-� RAFTER 2x6 @ 24°OG USED FOR THE BENEFIT OF ANYONE EXCEPT CEILING JOIST 2x6 A 24"OC BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC } O L w a. cD Ozer H ° t < LL 00r- 23'-4" 23'-4" < O 7 W ? 1 (E) LBW I (E) LBWI 2 F 6 Z 1 p (E) LBW (11-- o 'co O wco 47'-1" _ -, � Um O ce a_ 3'-1" — 3'-1" — 2'-1" 2'-1" La 24'-4" 24'-4" I I a) c WI, as J a) • C Z O CV Lli ./' Q 2 rn N CO O STRUCTURAL SIDE VIEW _ C' 00° Ct O /t) 0 2 RAFTER 2x6 @ 24'OC s/" Y/ CEILING JOIST 2x6 24 oc -0 LLI0 ' LL m ` i; p O >- Z J (n } LU >, O ct3 (/) - � o co co 410 .2 n I o 1- 0 co - DRAWING BY (E) LBW , (E) LBW (E) LBW , Eric Thomas 5 54'-5" - I DATE July 31, 2018 PROJECT NUMBER 53156741 SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4.1 0 • MODULE SPECIFICATIONS Sunmodule Plus SW 290M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 290 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG. HIGH TEMP MICROINVERTER TO AAX.SHORT CIRCUIT CURRRENT(ISC)= 13.0 A DCNo.orr MODULE VOC 40 V DC STATE Oregon JUNCTION BOX MAX.CURRENT(ISC X1.25)= 16.3 A DC MODULE VMP 31 V DC CITY Tigard CONDUCTOR(TC-ER,COPPER(90°C))= 12 AWG BLUE RAVEN MODULE IMP 9.3 ADC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 10 A DC ASHRAE EXTREME LOW TEMP(°C) -6 AMB.TEMP.AMP.CORRECTION = 0.96 VOC CORRECTION (%/°C) -0.3 °C ASHRAE 2%AVG.HIGH TEMP(°C) 32 ADJUSTED AMP.= 28.8 > 16.3 1220 S.630E STE.430 AMERICAN FORK,UT 84003 VMP CORRECTION(%/°C) -0.4 °C JUNCTION BOX TO AAX.SHORT CIRCUIT CURRRENT(ISC)= 13.0 A DC 800-377-4480 SERIES FUSE RATING 25 ADC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 COMBINER BOX MAX.CURRENT ISC X1.25 = 16.3 ADC ( ) WWW.BLUERAERAVENSONSOLAR.COM ADJ.MODULE VOC @ ASHRAE LOW TEMP 43.7 V DC NUMBER OF MODULES PER MPPT 9 13 INDUCTOR(THWN-2,COPPER(90°C))= 12 AWG CONFIDENTIAL-THE INFORMATION ADJ.MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 26.0 V DC DC POWER RATING PER CIRCUIT(STC) 2610 3770 CONDUCTOR RATING= 25 A HEREIN CONTAINED SHALL NOT BE TOTAL MODULE NUMBER 22 MODULES CONDUIT FILL DERATE= 1 USED FOR THE BENEFIT of ANYONE EXCEPT MICROINVERTER SPECIFICATIONS Enphase IQ7-60-2-US STC RATING OF ARRAY 6380W DC AMB.TEMP.AMP.CORRECTION = 0.76 BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN POWER POINT TRACKING(MPPT) MIN/MAX 22 - 48 V DC AC'CURRENT @ MAX POWER POINT(IMP) 9.0 13.0 ADJUSTED AMP.= 19 > 16.3 PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, MAXIMUM INPUT VOLTAGE 48 V DC MAX. CURRENT(IMP X 1.25) 11.25 16.25 EGC ISC= 13.0 A DC EXCEPT IN CONNEC TION WITH THE MAXIMUM DC SHORT CIRCUIT CURRENT 15 ADC OCPD CURRENT RATING PER CIRCUIT 20 20 MAX. CHANNEL ISC= 16.3 ADC SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE MAXIMUM USABLE DC INPUT POWER 350 W MAX. COMB.ARRAY AC CURRENT(IMP) 22.0 INDUCTOR(THWN-2,COPPER(90°C))= 10 AWG WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. MAXIMUM OUTPUT CURRENT 1 A AC MAX.ARRAY AC POWER 5280W AC EGC CONDUCTOR RATING= 60 A AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DEBATE= 1 >- 5 6 ' U) o MAXIMUM OUTPUT POWER 250 W AC VOLTAGE RISE CALCULATIONS DIST(FT)JRISE(V) VEND(V) %VRISE IQ7-6 AMB.TEMP.AMP.CORRECTION = 0.76 WZ U O CL ,r CEC WEIGHTED EFFICIENCY 97 % VRISE SEC. 1(MICRO TO JBOX) 21.6 0.52 240.52 0.22% 0 ADJ USTEDAMP.= 45.6 > 16.3 Q � op 0 p h VRISE SEC. 2(JBOX TO COMBINER BOX) 70 3.68 243.68 1.53% COMBINER BOX TO INVERTER RATED AMPS= 22.0 A AC Q 0 X I j 01 AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC. 3(COMBINER BOX TO POI) 10 0.56 240.56 0.23% MAIN PV OCPD MAX.CURRENT(RATED AMPS X1.25)= 27.5 A AC 2 1- 6 I- li o NOMINAL OPERATING AC VOLTAGE 240 VAC I TOTAL VRISE 1.98% INDUCTOR(THWN-2,COPPER(75°C)) = 10 AWG 0 p Wry 00 NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 35 A W 0 • U m MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= 1 0 MAXIMUM AC CURRENT 13.0 A AC AC OUTPUT CURRENT 22.0 A AC AMB.TEMP.AMP.CORRECTION = 0.96 IY 0_ MAXIMUM OCPD RATING PER CIRCUIT 20 A AC NOMINAL AC VOLTAGE 240 VAC ADJUSTED AMP.= 33.6 > 27.5 a) c CO J a) GROUNDING NOTES 10.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 c 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE,WITH[NEC 690-47]AND 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG INSULATED,90°C RATED,WET AND UV RESISTANT, RATED FOR 600V Z C [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED. PER NEC, SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER =N W GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND 11.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. Q N N cp CO BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 2 OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS D: 3W GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS 0 2 a) U CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66], DC FOLLOWS:DC POSITIVE-RED(OR MARKED RED), DC NEGATIVE-GREY(OR MARKED GREY) LL a) 5 I- 0> 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND SYSTEM GEC SIZED ACCORDING TO[NEC 250.166], MINIMUM#8AWG WHEN 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: z J CO -d ›- NO NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. DC POSITIVE-GREY(OR MARKED GREY), DC NEGATIVE-BLACK(OR MARKED BLACK) LU >, O ay CO ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 14.EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, 12.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: ~ O Q) 0 c° 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN PHASE A OR L1-BLACK, PHASE B OR L2-RED, PHASE C OR L3-BLUE, NEUTRAL- I a) ~ 0 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. WHITE/GRAY DRAWING BY 690.46]. *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY 1 Eric Thomas 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC WIRING&CONDUIT NOTES BE USED INSIDE 690.42]. 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND ""USE-2 IS AVAILABLE AS UV WHITE 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT APPROVED FOR THE SITE APPLICATIONS 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL DATE THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR 2.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31,NEC July 31, 2018 TO ANOTHER MODULE. CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT:ROUTED TO 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 14.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE PROJECT NUMBER IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC 53156741 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 690.8] FOR MULTIPLE CONDUCTORS 330.30(B). AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED SHEET NAME GROUNDING LUGS. AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO[NEC TABLE ELEC. CALCS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND 310.15(B)(2)(a),NEC TABLE 310.15(B)(3)(a),&NEC 310.15(B)(3)(c)]. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 5.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV PAGE NUMBER REVISION 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE PVc 0 STRANDED,AND BARE WHEN EXPOSED. USED TO PROTECT WIRE FROM SHARP EDGES V \to- Intertek AUTHORIZATION TO MARK BLUE RAVEN 'This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)ry' 1220 S.630 E STE.430 Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing AMERICAN FORK,UT 84003 Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing 800-377-4480 Report. I WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be • HEREIN CONTAINED SHALL NOT BE applied only at the location of the Party Authorized To Apply Mark. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TOTHERS OUTSIDE APPlicant: Unirac, Inc Manufacturer: Jiaxing Pacific EnergyEquipment Corp• RECIPIENTS ORGANIZATION . EXCEPT IN NNEC TION WITH THE No.8 Haiwan Ave SALE AND USE OF THE RESPECTIVE 1411 Broadway Blvd NE Hangzhou Bay Bdao New Area EQUIPMENT,WITHOUT THE Address: AtlClrtrsS: WRITTEN PERMISSION OF ' Albuquerque,NM 87102 Haiyan Economic Development Area BLUERAVENSOLAR LLC. Jiaxing City,Zhejiang Province Country: USA Country: China r*: . .T:; ri f cp Klaus Nicolaedis Lili Zeng o Z � I— J Contact: Contact: Jason Mayfield George Huang Z t rn 0 0 505-462-2190 510-979-1920 Q C0 1- CC Z M Phone: Phone: 505-400-2949 650-799-7627 2 1_ Lo Lo I— WI 0 oo FAX: NA FAX: NA klaus.nicolaedis@unirac.com Izeng@ccmfg.com LU U U Email: jasonm@unirac.com Email: george@ccmfg.com 0 D Et —J Party Authorized To Apply Mark: Same as Manufacturer CL co Report Issuing Office: Lake Forest,CA Control Number: 5003278 Authorized by: „ °. for Dean Davidson,Certification Manager I US ugnso Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to M ark isfor the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark Any further use of the Intertek name for the sale or advertisement of the tested material,product or sere ice must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are nut for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 546 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800.345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 2703 Issued: 2015101/28 Ed: 1 Mounting Systems, Mounting Devices,Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels Photovoltaic Mounting System, Sun Frame Micro Rail- Installed Using Unirac Installation Manual, Rev Product: PUB2017FEB16 Brand Name: Unirac SHEET NAME Models: Unirac SFM DATA SHEET ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2-Mar-2017 PAGE NUMBER REVISION ED16.3.16(1-Jul-161 Mandatory DS 0