Loading...
Correspondence 9 k February 24, 2005 a' •"� CITY OF TIGARD OREGON Walter Delsslee 2135 E Harvard Ct Visalia, CA RE: SWEET FACTORY—T I REVIEW Project Information „1/4.?< 'li Building Permit -BHP2045-00449 Construction Type: II-B Tenant Name: Sweet Factory Occupancy Type: M Address: £\L4UA--931-5 SW Washington Sq Occupant Load: 30 Area: 866 sq ft Stories: 1 The plan review was pciormed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition;and 2003 International Fire Code (OFC) as amended by TVF&R.The submitted plans are approved subject to the following conditions. 1. Combustible materials shall be permitted in buildings of Type I or II construction in the following Applications. OSSC 603.1 1. Fire-retardant-treated wood shall be permitted in: 1.1. Nonbearing partitions where the required fire-resistance rating is 2 hours or less. 1.2. Nonbearing exterior walls where no fire rating is required. 1.3. Roof construction as permitted in Table 601,Note c,Item 3. 2.Thermal and acoustical insulation, other than foam plastics,having a flame spread index of not more than 25. Exceptions: # 5. Interior floor finish and interior finish,trim and millwork such as doors,door frames, window sashes and frames. 6.Where not installed over 15 feet(4572 mm) above grade, show windows,nailing or furring strips,wooden bulkheads below show windows,their frames,aprons and show cases. 7. Finished flooring applied directly to the floor slab or to wood sleepers that are fire stopped in accordance with Section 717.2.7. 8.Partitions dividing portions of stores,offices or similar places occupied by one tenant only and which do not establish a corridor serving an occupant load of 30 or more shall be permitted to be constructed of fire-retardant-treated wood, 1-hour fire-resistance-rated construction or of wood panels or similar light construction up to 6 feet in height. Etc 2. Horizontal sliding or vertical security grilles or doors that are a part of a required means of egress shall conform to the following. 1.They shall remain in the full open position during the period of occupancy by the general public. 2. Doors or grilles shall not be brought to the closed position when there are more than 10 13125 SW Hall Blvd., Tigard, OR 97223 (503)639-4171 TDD(503)684-2772 persons occupying spaces served by a single exit or 50 persons occupying spaces served by more than one exit. 3.The doors or grilles shall be openable from within without the use of any special knowledge or effort where the space is occupied. 4.Where two or more exits are required,not more than one-half of the exits shall be permitted to include either a horizontal sliding or vertical rolling grille or doors. 402.11 OSSC 3. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 4.The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied.The means of egress illumination shall be provided with a second source of power in case of primary power loss. 1006.2 OSSC 5.Accessible checkout aisles shall be on an accessible route and at least 36 inches wide. Counters in accessible checkout aisles shall be not more than 38 inches (965 mm) high and the top of the raised edge of the counter shall not exceed 40 inches (1016 mm) in height above the finished floor.Accessible checkout aisles shall be identified by the international symbol of access. OSSC section 1109.19, 1109.23.3 6. Safety glazing including but not limited to:the following locations: Each unit of glazing shall be permanently identified by the manufacturer. 2406 OSSC. Some of these locations are as follows: a.Glazing in ingress and means of egress doors. b.Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. 7. Doors to unisex toilet and bathing rooms shall be securable from within the room and be provided with a privacy lock and an"occupied" indicator. 1109.10.124 OSSC 8. Floor drains shall not be located within the clear floor space at a lavatory,water closet,urinal, or bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2- percent slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of level. Exception:Floor drains may be located within a clear,floor space at a fixture provided the openings in the drain cover shall not exceed /z inch (12.7 mm)in any direction and the drain cover shall be no more than 1/8 inch below the level of the surrounding finished floor surface. 1109.10.1 OSSC 9.American with Disabilities Act(ADA): It shall be the responsibility of the Architect,Engineer, Designer, Contractor,Owner and Lessee to research the applicability of the ADA requirements for the structure.The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC,which may not include all of the requirements of the ADA. 10. Deferred submittals such as Fire Alarm, Fire Sprinkler,Truss Joist Shop Drawings, etc,will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be$200.00. Approved Plans: 1 set of approved plans,bearing the City of Tigard approval stamp,shall be maintained on the jobsite.The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification:Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information,please attach a copy of the enclosed City of Tigard, Letter of TransmittaL The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull _ er/91, " Val Henzel, Senior Plans Examiner