Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (447)
❑ CONFORMS TO DESIGN CONCEPT POLYGON \ 3 q Sw ,C,..-1/4N-\d C_ \.c-N Z CONFORMS TO DESIGN CONCEPT WITH 14" OPEN WEB JOIST @ 19.2" O.C. 2610 BC REVISIONS AS SHOWN El CONFORMS TO DESIGN CONCEPT PL13-290 UP H ❑ NON-CONFORMING - REVISE AND RESUBMIT ❑ CONFORMS TO DESIGN CONCEPT WITH 12/2/2013 THIS SHOP DRAWING HAS BEEN REVIEWED-FOR GENERAL CONFORMANCE REVISIONS NOTED WITH THE DESIGN CONCEPT ONLY AND DOES NOT RELIEVE THE El NON-CONFORMING—REVISE&RESUBMIT Products FABRICATOR/VENDOR OF RESPONSIBILITY FOR CONFORMANCE WITH THE DESIGN DRAWINGS AND SPECIFICATIONS ALL OF WHICH HAVE PRIORITY THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCE PIotID Length Product Plies Net Qty OVER THIS SHOP DRAWING. CONTRAC'CR SHALL VERIFY ALL DIMENSIONS. WITH DESIGN CONCEPT ONLY DOES NOT RELIEVE THE FABRICATORNENDOR OF RESPONSIBILITY DOR CONFORMANCE WITH DESIGN RM1 36-00-00 1" x 14" APA Rim Board 1 1 By: Todd R. Eaton Date: September 19, 2014 DRAWINGS, SPECIFICATIONS,AND APPLICABLE CODES,ALL OF WHICH HAVE RM1 1 7-00-00 1" x 14" APA Rim Board 1 1 CT ENGINEERING INC PRIORITY OVER THIS SHOP DRAWING. By Alexia Fukui Date 9/22/14 RM1 13-00-00 1" x 14" APA Rim Board 1 1 MILBRANDT ARCHITECTS RM1 3-00-00 1" x14" APA Rim Board 1 1 RM1 2-00-00 1" x 14" APA Rim Board 1 1 BM19 15-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM9 10-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 2 BM7 9-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM18 8-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM3 7-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM10 BK1 6-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 ° ° ° [ CA 1-07-03 BM3 6-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM11 5-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 2 ° r __ ® BM1•';; n CONFORMS TO DESIGN CONCEPT POLYGON Z CONFORMS TO DESIGN CONCEPT WITH 14" OPEN WEB JOIST @ 19.2" O.C. 2610 BC REVISIONS AS SHOWN PL13-290 UP H ❑X CONFORMS TO DESIGN CONCEPT I—] NON-CONFORMING - REVISE AND RESUBMIT I ❑ CONFORMS TO DESIGN CONCEPT WITH 12/2/2013 THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCE REVISIONS NOTED WITH THE DESIGN CONCEPT ONLY AND DOES NOT RELIEVE THE Products FABRICATOR/VENDOR OF RESPONSIBILITY FOR CONFORMANCE WITH THE, ❑ NON-CONFORMING—REVISE&RESUBMIT DESIGN DRAWINGS AND SPECIFICATIONS ALL OF WHICH HAVE PRIORITY THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCE PIotID Length Product Plies Net Qty OVER THIS SHOP DRAWING. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. WITH DESIGN CONCEPT ONLY AND DOES NOT RELIEVE THE RM1 36-00-00 1" x 14" APA Rim Board 1 1 FABRICATORNENDOR OF RESPONSIBILITY FOR CONFORMANCE WITH DESIGN By: Todd R. Eaton Date: September 19, 2014 DRAWINGS,SPECIFICATIONS,AND APPLICABLE CODES,ALL OF WHICH HAVE RM1 17-00-00 1" x 14" APA Rim Board 1 1 CT ENGINEERING INC PRIORITY OVER THIS SHOP DRAWING. „...... By Alexia Fukui Date 9/22/1.4 RM1 13-00-00 1" x 14" APA Rim Board 1 1 MILBRANDT ARCHITECTS RM1 3-00-00 1" x14" APA Rim Board 1 1 -... RM1 2-00-00 1" x 14" APA Rim Board 1 1 BM19 15-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM9 10-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 2 BM7 9-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM18 8-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 BM10 BM3 7-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 1-07-03 jl e n 13 BK1 6-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 A u * • Flo BM3 6-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 E m` ° . I Flo -__ 4 BM11 5-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 2 mi II BM19 ,_II IZIMI�PI --- ----© ,�Y ° Y•..b I BK1 4-00-00 1.5 Rigid Lam LVL 1-3/4 x 14 1 1 l ` mi-1 -Ilo d1 F07 ,I BK1 3-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 2 - ° H F07 = BM4 3-00-00 1.5 RigidLam LVL 1-3/4 x 14 1 1 ' BM10 26-00-00 3-1/2 X 14 BIG BEAM 1 1 II, 19-05:00 F07 LB M 8 14-00-00 3-1/2 X 14 BIG BEAM 1 1 1 ° ° Fol I BM2 10-00-00 3-1/2 X 14 BIG BEAM 1 1 ° ,;. ° ° �I1 0 F07 1BM1 18-00-00 5-1/2 X 14 BIG BEAM 1 1 1 ° F05 ° ° Iii BM3 BK1=BLOCKING D5 ° ° w RM1=RIM BOARD I ° �' IBM ACCESSORIES QTY 1; • ° ° III A® TH017140-2 43 1, 1 F04 II © HUCQ1.81/11 6 T l � • 0 • ° Q F04 <1 1x14 OSB RIM FOR SHEAR BLOCKING 28' I Ig • ° 0 ° • ° 01 I 0 co ISHEAR BLOCKING PLACEMENT PER STRUCTURAL PLAN • ° ° � I j$ ° Fix II HVAC DIAGRAM ON LAYOUT IS A GENERAL GUIDE ONLY. ° .0 ,.`1k•_--" BM3_ FLOOR DESIGNED TO MEET OR EXCEED L/480 DEFLECTION CRITERIA ° • ° �;