Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications (77)
Poject: RECEIVED page Keith A Kudrna Location: Footing"C" r ai ° ''Suntel Design Footing *', 16865 Boones Ferry Rd of [2012 International Building Code(2012 NDS)] ANUG 2 3 2017 �� �. zLake Oswego,Oregon 97035 Footing Size:3.5 FT x 3.5 FT x 12.00 IN Reinforcement:#4 Bars©7.00 IN.O.C. E/W/(6 ii `"y OF" A y' StruCalc Version 9.0.1.7 9/17/2015 1:15:44 PM Section Footing Design Adequate l BUMPING PIVISIM 5-1 X17— 2-ct I FOOTING PROPERTIES LOADING DIAGRAM l Cl 5c_ AtA4l I Allowable Soil Bearing Pressure: Qs= 1500 psf [,� Concrete Compressive Strength: Fc= 2500 psi I Reinforcing Steel Yield Strength: Fy= 40000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 3.5 ft Length: L= 3.5 ft Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 8.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 4 in Column Depth: n= 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 1224 psf f--4inH Effective Allowable Soil Bearing Pressure: Qe= 1350 psf Required Footing Area: Areq= 11.11 sf Area Provided: A= 12.25 sf Baseplate Bearing: Bearing Required: Bear= 21000 lb 12 in Allowable Bearing: Bear-A= 44200 lb n n n Beam Shear Calculations(One Way Shear): T Beam Shear: Vu1 = 6375 lb Sin Allowable Beam Shear: Vc1 = 25988 lb Punching Shear Calculations(Two Way Shear): I 3.5 ft Critical Perimeter: Bo= 49 in Punching Shear: Vu2= 19214 lb FOOTING LOADING Allowable Punching Shear(ACI 11-35): vc2-a= 90956 lb Live Load: PL= 0 lb Allowable Punching Shear(ACI 11-36): vc2-b= 132413 lb Dead Load: PD= 15000 lb Allowable Punching Shear(ACI 11-37): vc2-c= 60638 lb Total Load: PT= 15000 lb Controlling Allowable Punching Shear: vc2= 60638 lb Ultimate Factored Load: Pu= 21000 lb Bending Calculations: Weight to resist uplift w/1.5 F.S.: U.R.= 1184 lb Factored Moment: Mu= 110250 in-lb Nominal Moment Strength: Mn= 338532 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0.53 in Steel Required Based on Moment: As(1)= 0.38 in2 Min.Code Req'd Reinf.Shrink./Temp.(ACI-10.5.4):As(2)= 1.01 in2 Controlling Reinforcing Steel: As-reqd= 1.01 in2 Selected Reinforcement: #4's @ 7.0 in.o.c.e/w(6)Min. Reinforcement Area Provided: As= 1.18 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 18 in 1 P oject:TYPICAL FOOTINGS page Judith Souers Location: Footing'D' Suntel Design Footing 16865 Boones Ferry Rd Suite 201 [2015 International Building Code(2012 NDS)] of Footing Size:3.75 FT x 3.75 FT x 12.00 IN ,, Lake Oswego,OR 97035 Reinforcement:#4 Bars @ 7.00 IN.O.C. E/W/(6)min. StruCalc Version 9.0.2.5 6/26/2017 2:51:30 PM Section Footing Design Adequate FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 40000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 3.75 ft Length: L= 3.75 ft Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 8.25 in COLUMN AND BASEPLATE SIZE Column Type: Steel Column Width: m= 4 in Column Depth: n= 4 in Baseplate Width: bsw= 4 in Baseplate Length: bsl= 4 in FOOTING CALCULATIONS Bearing Calculations: I—a;nH Ultimate Bearing Pressure: Qu= 1244 psf i I Effective Allowable Soil Bearing Pressure: Qe= 1350 psf Required Footing Area: Areq= 12.96 sf Area Provided: A= 14.06 sf Baseplate Bearing: 12 in Bearing Required: Bear= 24500 lb P a a a o Allowable Bearing: Bear-A= 44200 lb sin Beam Shear Calculations(One Way Shear): Beam Shear: Vu1 = 6669 lb f 3.75 ft Allowable Beam Shear: Vc1 = 27844 lb Punching Shear Calculations(Two Way Shear): FOOTING LOADING Critical Perimeter: Bo= 49 in Live Load: PL= 0 lb Punching Shear: Vu2= 22684 lb Dead Load: PD= 17500 lb Allowable Punching Shear(ACI 11-35): vc2-a= 90956 lb Total Load: PT= 17500 lb Allowable Punching Shear(ACI 11-36): vc2-b= 132413 lb Ultimate Factored Load: Pu= 24500 lb Allowable Punching Shear(ACI 11-37): vc2-c= 60638 lb Weight to resist uplift w/1.5 F.S.: U.R.= 1359 lb Controlling Allowable Punching Shear: vc2= 60638 lb Bending Calculations: Factored Moment: Mu= 114401 in-lb Nominal Moment Strength: Mn= 339278 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0.49 in Steel Required Based on Moment: As(1)= 0.39 in2 Min.Code Req'd Reinf.Shrink/Temp.(ACI-10.5.4):As(2)= 1.08 in2 Controlling Reinforcing Steel: As-reqd= 1.08 in2 Selected Reinforcement: #4's @ 7.0 in. o.c.e/w(6)Min. Reinforcement Area Provided: As= 1.18 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 17.5 in NOTES P}O)eCt: page Location: Footing"E., Keith A Kudrna Footing Suntel Design [2012 International Building Code(2012 NDS)] s 16865 Boones Ferry Rd or Footing Size:4.0 FT x 4.0 FT x 12.00 IN FLake Oswego,Oregon 97035 Reinforcement:#4 Bars @ 8.00 IN.O.C. E/W/(6)min. StruCalc Version 9.0.1.7 9/17/2015 1:18:41 PM Section Footing Design Adequate FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 40000 psi Concrete Reinforcement Cover: C= 3 in FOOTING SIZE Width: W= 4 ft Length: L= 4 ft Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 8.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 4 in Column Depth: n= 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 1250 psf Effective Allowable Soil Bearing Pressure: Qe= 1350 psf Required Footing Area: Areq= 14.81 sf I-4 in { Area Provided: A= 16.00 sf Baseplate Bearing: Bearing Required: Bear= 28000 lb Allowable Bearing: Bear-A= 44200 lb 12 in Beam Shear Calculations(One Way Shear): P c, ,, 9 Beam Shear: Vu1 = 9188 lb Sin Allowable Beam Shear: Vc1 = 29700 lb Punching Shear Calculations(Two Way Shear): 4e Critical Perimeter: Bo= 49 in Punching Shear: Vu2= 26176 lb FOOTING LOADING Allowable Punching Shear(ACI 11-35): vc2-a= 90956 lb Live Load: PL= 0 lb Allowable Punching Shear(ACI 11-36): vc2-b= 132413 lb Dead Load: PD= 20000 lb Allowable Punching Shear(ACI 11-37): vc2-c= 60638 lb Total Load: PT= 20000 lb Controlling Allowable Punching Shear: vc2= 60638 lb Ultimate Factored Load: Pu= 28000 lb Bending Calculations: Weight to resist uplift w/1.5 F.S.: U.R.= 1547 lb Factored Moment: Mu= 168000 in-lb Nominal Moment Strength: Mn= 339930 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0.46 in Steel Required Based on Moment: As(1)= 0.57 in2 Min.Code Req'd Reinf.Shrink./Temp.(ACI-10.5.4):As(2)= 1.15 in2 Controlling Reinforcing Steel: As-reqd= 1.15 in2 Selected Reinforcement: #4's©8.0 in.o.c.e/w(6)Min. Reinforcement Area Provided: As= 1.18 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 21 in