Report (95) My\C - ccs L VCkAc‘O_ Vt-V,‘) TRANE Submittal Date: May 23, 2018 Job Name: Courtyard Marriott Tigard-Energy Turnkey 15686 SW Sequoia Pkwy TIGARD, OR 97224 Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Indirect Fired Gas Heating Units (Outdoor) The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid fora period of 6 months from the date of submittal generation. If six months or more has elapsed David Strasser between submittal generation and equipment release,the product Trane performance and submittal data will need to be verified. It is the 7257 SW Kable Lane customer's responsibility to obtain such verification. Portland, OR 97224-7181 Phone: (503)620-8031 Cell: (503)602-8969 Fax: (503) 639-1454 RE Odi TVE AUG 1 6 2018 CITY OF'TGARD BUILDING DIVISION J:IJOBSl124170040121GRAA Sub Ver 1.doc Table Of Contents Product Summary 1 Indirect Fired Gas Heating Units(Outdoor) (Item Al) Tag Data 3 Mechanical Specifications 4 Unit Dimensions 6 Weight, Clearance&Rigging Diagram 7 Field Wiring 8 Courtyard Marriott Tigard-Energy Turnkey May 23,2018 Tag Data-Indirect Fired Gas Heating Units(Outdoor (Qty: 1) Item Tag(s) Qty Description Model Number • Al No Tag 1 Outdoor Gas Heating Unit GRAA25GDMFO Rooftop gas heating unit Standard temperature rise furnace 20-60 F (-7- 16 C) per furnace-left hand 250 MBH input Gravity venting 208/60/3 main power supply Electronic modulating gas control with external 0- 10vdc input Natural gas with 100% lockout 409 stainless steel heat exchanger Rooftop arrangement D-Standard blower with evaporative cooler 3 HP supply fan motor with VFD Factory installed VFD Single speed high efficiency open drip proof motor 100% outside air opening 2-position outside air damper/spring return 12" (305 mm)evaporative media (Celdek) Standard filters item#1 of 1 (ID#43188) Performance Selection Parameters Selected Unit Performance Data Selection Method=Performance Air Flow SCFM-(cu. m/s)=3,800(1.77) SCFM=3,800 Temperature Rise-°F(SC)=48.51(26.94) Temp. Rise=48.51 Output BTU/HR-(kW/H)=200,000(58.60) Req. BTU Out=200,000 External Static Pressure in.WC-(Pa)=1.00(248.00) Altitude=Below 2000' Total Static Pressure in.WC-(Pa)=1.27(315.03) DeRate=0% Brake Horse Power BHP-(kW)=2.16(1.61) ESP=1 in.WC @ Sea Level Fan Speed RPM= 1075 MCA=13.205 MOP=21.705 DSS= 12.742 Approx. Shipping Weight=1277 lbs.each FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 3 of 8 Others Courtyard Marriott Tigard-Energy Turnkey May 23,2018 Mechanical Specifications-Indirect Fired Gas Heating Units(Outdoor) Item: Al Qty: 1 General Units are completely factory assembled, piped, wired and test fired.All units contain duct furnaces that are ETL certified and conform with the latest ANSI Standards for safe and efficient performance. Units are mounted on metal rails with • lifting and anchor holes and are suitable for slab or curb mounting. Units are available for operation on either natural or LP (propane) gas. The firing rate of each furnace will not exceed 400 MBh and contains its own heat exchanger, flue collector,venting, burners, safety and ignition controls.All units are ETL certified for electrical safety in compliance with UL 1995 and CSA C22.2 No.236 safety standard for heating,ventilating and cooling equipment. Standard control relays socket mounted with terminal block connections. All control wiring terminates at terminal strips(single point connection)and include an identifying marker corresponding to the wiring diagram. Motor and control wiring is harnessed with terminal block connections.Casings are die formed, 18 gauge[1.3 mm]galvanized steel and finished in air dry enamel. Service and access panels are provided through easily removable side access panels with captive fasteners. Fan sections and supply plenums (when provided) are insulated with fire resistant, odorless, matte faced 1"[25 mm]glass fiber material. Outside air hoods, when provided, ship with a wire mesh inlet screen. Standard heat exchanger construction consists of 20 gauge[1.0 mm]aluminized steel tubes and 18 gauge[1.3 m] aluminized steel headers. Standard drip pan construction is corrosion resistant aluminized steel. Standard flue collector construction is corrosion resistant aluminized steel. Burners are die formed, corrosion resistant aluminized steel, with stamped porting and stainless steel port protectors. Port protectors prevent foreign matter from obstructing the burner ports. Burners are individually removable for ease of inspection and servicing. The entire burner assembly is easily removed with its slide out drawer design. The pilot is accessible through an access plate without removing the burner drawer assembly. Filter rack is constructed of galvanized steel with access through the side service panel. Electrical cabinet is isolated from the air stream with a non removable access panel interior to the outer service panel. There is provision in this cabinet for component mounting, wire routing and high voltage isolation. Motor and control wiring is harnessed with terminal block connections. Standard units are provided with 24 volt combination single stage automatic gas valves, including main operating valve and pilot safety shutoff, pressure regulator, manual main and pilot shutoff valve, and adjustable pilot valve. Gas valves are suitable for NEC Class 2 use for a maximum inlet gas pressure of 0.5 psi (14" W.C.)[3.4 kPa]on natural gas.All rooftop units are provided with a low voltage circuit breaker rated for 150%of the units normal 24 volt operating load. Each duct furnace is provided with a 24 volt high temperature limit switch, a (redundant)combination gas valve and a fan time delay relay. The fan time delay relay delays the fan start until the heat exchanger reaches a predetermined temperature. It also allows the fan to operate after burner shutdown, removing residual heat from the heat exchanger. Double and triple furnace units contain a reverse airflow interlock switch. The normally closed switch, when activated, causes the gas valves to close and continue blower operation.All units provided with a solid state ignition control system which ignites the intermittent pilot by spark during each cycle of operation.When pilot flame is proven, main burner valve opens to allow gas flow to the burners. Pilot and burners are extinguished during the off cycle. Standard Temperature Rise Furnace Each duct furnace shall have a lower pressure drop across the heat exchanger, allowing higher air flow capacities and an 80% eff rating with delta T of 20-60F per furnace. Air Handling Fan(s) Centrifugal fan is belt driven,forward curved with double inlet, statically and dynamically balanced. The blower wheel is fixed on a keyed shaft, supported with rubber grommet on bearing only and ball bearing secured. An access interlock switch is installed in the blower compartment and will disengage the blower upon removing the service panel. An override is incorporated into the access interlock switch for serviceability. Natural vent Natural vent units are provided with a vent cap designed for gravity venting. Outside air for combustion enters at the base of the vent cap through a protective grille, and products of combustion are discharged through the upper section of the flue vent cap. Evaporative Cooler An evaporative cooler with 8" [203 mm] media is provided. The evaporative cooler is of a self cleaning design with a stainless steel water tank, regulated water flow and overflow protection. The cooler has a cabinet assembly of heavy gauge aluminized steel with weather proof finish,a UL recognized thermally protected sealed re-circulating pump motor, 2" [51 mm] distribution pad and corrosion resistant PVC water distribution tubes. FLO=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 4 of 8 Others Courtyard Marriott Tigard-Energy Turnkey May 23,2018 Electronic Modulating 4-20 mA/0 -10 VDC Gas Control Provides modulated heat output. Ignition is at full fire(100% input), and modulates the gas input from 100%to 40% rated input. The modulating gas valve shall operate in response to a 4-20 mA or a 0- 10 VDC input from an external DDC control.When"furnace one only" is specified on double and triple furnaces, additional furnace sections will have single stage on/off control. Type 409 Stainless Steel Heat Exchanger Heat exchanger tubes and headers shall be 20 gauge[1.0 mm]type 409 stainless steel. Burners and flue collector shall be 409 Stainless Steel. 409 stainless steel is recommended where outside air is used for make up air in areas where outside temperatures are 40 F [4 C] or below. Dampers-General Dampers are of the opposed blade type, constructed of galvanized steel with neoprene nylon bushings, blades to be mechanically interlocked. Units with outside air or return air only are provided with damper,two position spring return damper motor and controls. The motor powers the damper full open when the unit is on and full closed when the unit is off. Factory Installed VFD A Variable Frequency Drive(VFD)shall be provided when variable air volume control is required for fan operation. The VFD shall be properly sized, factory mounted and wired to the fan motor. The VFD shall provide overload protection and soft start operation. The VFD shall be covered by UL 1995 Standards and manufactured with a NEMA 1 plenum rated enclosure. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 5 of 8 Others Courtyard Marriott Tigard-Energy Turnkey May 23,2018 Unit Dimensions-Indirect Fired Gas Heating Units (Outdoor) Item: Al Qty: 1 Front Back 43 7/8" 231/2" - (TYP) _, 16"(US) _ 11/8" 253116"'(Can) -- 2 3/4" I r Im L 1 I 1 1 t 390 30 1/2" 44" 1I 10 1/8" 1 6„ .7�f't�C-1 5" 4 29 5/16" Discharge 1" Opening 1 1 5/16" 0 42 1/16" ryp. uutsice Anchor Hole Location 9/16"Hole Right 1" 72 1/4" 36" -� Typ. 26" Evaporative Cooler Vent Cap Ship Separate a I 39" 8 0 o e ,, 1" 1 b____i_4" , Curb Cap 5/8" 77 3/8" ryp, I1 Anchor Hole Location 9/16'Hole Left -00-- 36" ---,=0-0---- 72 1/4" —r 1" Typ. I Evaporative I 26" Cooler v.Cap Ship Separate x..-97/6" I I } + =1:039 o oto o � 4" V ( `" /Electrical • 4811/160 1/16"4 I5/8"J Typ. - 77 3/8" I Anchor Hole Location 9/16"Hole FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 6 of 8 Others e. Courtyard Marriott Tigard-Energy Turnkey May 23,2018 Weight, Clearance& Rigging Diagram -Indirect Fired Gas Heating Units(Outdoor) Item: Al Qty: 1 II AIR FLOW 11 18" 1 18 18"„.,..e..„.„„ 34 1/2" WEIGHT DISCRIPTION 882.0 lb UNIT WEIGHT 1022.0 lb SHIP WEIGHT MOTOR WEIGHT 51.Olb HOOD WEIGHT 166.0 lb EVAP COOLER WEIGHT 386.01b EVAP COOL SHIP WEIGHT FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 7 of 8 Others I Variable Freq.Drive i_ D C a 11 t L1 ❑ . ❑ L1-I 1- urn ❑ BK ❑ ——�/ \ � < d ` .� L3 p BK • O L2 H F V/T2 0 RD 0 ———1 Blowert1 3 3 CO so CD L. 1 L. L3 ❑ BD ❑ L3---♦ F W/T3 ❑ BL ❑ \\ /, M M Q. Disconnect ❑ — r • 0 `C Line GND GR GR GNDI Q. :I Voltage - - 03 o z a .9 . m CD >v 3 ,– �� cofi < � � m � ga CD Y R m r� Q000a4aQQ Q m r_ _ o TA1 'l hJv I LVFJ —1O O -. W 250VA - 1 VFD Enable Relay I Q. 115V I NJ Rooftop Unit U I r 03 C Ca m L_ J 0 3 F KEY = 'r 0. L N GR _ BY MANUFACTURER C W uy E❑ Ambient Air _BY OTHERS OR OPTIONS CO .a VFD Temp 120 VAC IT ❑ GRIll Temp Sensor 1] TERMINAL BLOCK OR • Control FIELD CONNECTION POINT M VFD _i__WIRE CROSSING Heater Fan I I _ J NO CONNECTION C L N L N m o- I I —+—WIRE CONNECTION = Y11 � u � sCOLOR KEY F BL-BLUE O m m, 5 RD-RED A m m WH-WHITE C C• I I HAZARDOUS ARINING VARIABLE FREQUENCY DRIVE BK-BLACK sz S. _AMAAAAA (,–,f WITH LOW TEMP OPTION-THRU 5 HP GR-GREEN 0 —V V — U DISCONNECT ALL ELECTRIC POWER co INCLUDING REMOTE DISCONNECTS AND 0 FOLLOW LOCK OUT AND TAG PROCEDURES Fan BEFORE SERVICING.INSURE THAT ALL 0.1. MOTOR CAPACITORS HAVE DISCHARGED G Motor STORED VOLTAGE.UNITS WITH VARIABLE O. SPEED DRIVE.REFER TO DRIVE a INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. NOTES: ®AVERTISSEMENT 1)ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL TENSION DANGEREUSE! COUPER TOMES LES TENSIONS ET ELECTRIC CODE(NEC)AND LOCAL BUILDING CODES. OLORIR LES SECTIONNEURS A DISTANCE. PUTS SUIVRE LES PROCEDURES DE 2)USE COPPER CONDUCTORS ONLY. VERRouauGE ET DES ETIQUETTES AVANT TOUTS INTERVENTION.VERIFIER SUE TOUS NOTICE LES CONDENSATEURS DES MOTEURS SONT DECHARGES.DANS LE CAS° NITES COMPORTANT DES ENTRAINEUENrS A USE COPPER CONDUCTORS ONLY! VITESSE VARAIBIE.SE REPORTER AUX INSTRUCTIONS DE L'ENTRAINEMENT POUR UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OECHARGER LES CONDENSATEURS. OTHER TYPES OF CONDUCTORS. NE PAS RESPECTER CES MESURES DE FAILURE TO DO THE ABOVE COULD RESULT IN PRECAUTION PEUTENTRAINER DES EQUIPMENT DAMAGE. BLESSURES GRAVES PO WANT ETRE MORTELLES. AVIS ®ADVERTENCIA N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! iVOLTAJE PELIGROSO! LES BORNES DE L'UNITE NE SONT PAS CONEUES DESCONECTE TODALAENERGIAELECTRICA, POUR RECEVOIR°'AUTRES TYPES DE CONDUCTEUR S. INCLUSO LAS DESCONEXIONES REMOTAS Y FAIRE DEFAUT A LA PROCEDURE CI-DESSUS PEAT SIGH LOS PROCEOMIENTOS DE CIERRE Y L ENTRAINER DES DOMMAGES A L'EOUIPEMENT. SERVI IO A EGORNTES S P E QUE TO 0 LOS CA O.ASEGUR DEL OUETODOS AV I S O LOS CAPACITORES DEL MOTOR HAYAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES CON EJE DE jUTILICE 11NICAMENTE CONDUCTORES DE COBRE! DIRECCION DE VELOCIDAD VARIABLE,CONSUL LAS TERMINALES DE LA UNIOAD NO ESTAN DISENADAS CONSULTS LAS INSTRUCCIONES PARA LA PARA ACE PTAR OTROS TIPOS DE CONDUCTOR ES. DESCARGA DEL CONDENSADOR. K EL NO REALIZAR LO ANTERIORMENTE 5) NO SEGUIR LAS INSTRUCCIONES ANTERIORES PUEDE INDICADO,PODRIAOCASIONAR LA MUERTE cu PROVOCAR DAROS EN EL EQUIPO. OSERAS LESIONES PERSONALES. N W CO OD N O_ co -.. Oo co I