Report (84) vOIC11.1)0 Northwest .Fire Suppression, Inc. EQUIPMENT LIST ITEM MODEL DESCRIPTION 1 MS- Fire Alarm Control Panel 98000DLS 2 IPGSM-4G Commercial Fire Alarm Communicator 3 SD355 Addressable Smoke Detector 4 BG-12LX Addressable Manual Pull Station 5 MDF-300 Addressable Dual Point Monitor Module 7 P2RK Outdoor Horn strobe With Back Box 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.com CCB#088629 Licensed • Bonded • Insured this data sheet. ©2012 System Sensor. AVDS01201•3/12 Product specifications subject to change without notice.Visit systemsensor.com for current product information,induding the latest version of df-60334:A4•A1-100 MS-9600LS(E)/MS-96000DLS(E) j Fire Lrre®ALarms Intelligent Addressable FACP with Optional 2nd Loop by Honeywell Addressable General Fire•Lite's MS-9600LS(E)and MS-96000DLS(E)are compact, -- cost effective, intelligent addressable FACPs(Fire Alarm Con- trol Panels) with an extensive list of powerful features. The combination of Fire•Lite's newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-96000DLSE FACP, offer the latest in fire protection tech- nology. LiteSpeedTM is a patented technology that polls 10 devices at a time looking for new or different information. 6.1 When new information is found at a specific address, the sys tem polls that device several times for any new data. This , improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With this new polling scheme, ,S- «s devices can be wired on standard twisted, unshielded wire up ,E••�� >.� to a distance of 10,000 feet per loop. Each Signaling Line Cir- cuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ioniza- tion, photoelectric duct,fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 nwaveal addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay MEMBRANE SWITCH CONTROLS (two Form-C)modules. • ACKNOWLEDGE/STEP The FLPS-7 power supply is a separate board while all other • ALARM SILENCE electronics are contained on a single main circuit board. Both • DRILL boards are mounted to a quick-removable chassis and housed . SYSTEM RESET(lamp test) in a metal cabinet.The backbox can be installed allowing field wiring to be pulled.When construction is completed,the chas- • 12-key pad with full alphabet sis with the electronics can be quickly installed with two bolts. • 4 cursor keys The MS-96000DLS(E) includes a factory-installed DACT-UD2 • ENTER Digital Alarm Communicator Transmitter. The DACT transmits system status(alarm, troubles,AC loss, etc.)to a Central Sta- Special Features tion via internet (optional IPDACT installed) or the public • Easy mount chassis. switched telephone network. • 7 amp switching power supply. Optional modules, which plug into the main circuit board, are • Large enclosure allows 18 amp hour batteries available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box • DACT-UD2 plug-in communicator standard with transmitter, digital alarm communicator/transmitter, SLC MS-96000DLS/E. expansion module, local and remote upload/download soft- • Optional IPDACT Internet Protocol Digital Alarm ware and remote power expansion. Communicator/Transmitter FM APPROVED to UL ANSI 864. • Four Style Y(Class B)or two Style Z(Class A) NAC circuits. Controls And Indicators • Selectable strobe synchronization per NAC for System Sensor,Wheelock,and Gentex devices. LED INDICATORS • Automated control of ACC-25/50(ZS/T) audio speaker cir- • AC POWER(green) cults • FIRE ALARM (red) • ANN-BUS for connection to following optional modules • SUPERVISORY(yellow) Note:cannot be used if ACS annunciators are used. • ALARM SILENCED(yellow) • ANN-80(-W)Remote LCD Annunciator • SYSTEM TROUBLE(yellow) • ANN-I/O LED Driver Module • MAINTENANCE/PRESIGNAL(yellow) • ANN-S/PG Serial/Parallel Printer Module • DISABLED(yellow) • ANN-RLY Relay Module • BATTERY FAULT(yellow) • ANN-LED Annunciator Module • GROUND FAULT(yellow) • ANN-RLED Annunciator Module(alarms only) df-60334:A4•12/29/2009—Page 1 of 6 Standard Features • Optional 4XTMF module (conventional reverse polarity/city box transmitter). SLC LOOP • SLC can be configured for NFPA Style 4, 6,or 7 operation. Field-programming Features • SLC supports up to 318 addressable devices per loop(159 Off-line Programming: Create the entire program in your detectors and 159 monitor,control,or relay modules). office using a Windows®-based software package (order pro- • SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG gramming kit PK-CD, containing PS-TOOLS, separately). (3.1 mm2)using twisted,unshielded wire(see Wire Table on Upload/download system programming locally to the page 5). MS-9600LS/E in less than one minute. NOTIFICATION APPLIANCE CIRCUITS(NACS): Autoprogramming: Command the MS-9600LS(E)to program itself(takes less than 30 seconds). In the Auto-Program mode, • Four onboard NACs with additional NAC capability using the MS-9600LS(E) scans for all possible devices at all output control modules(CMF-300 or CMF-300-6). The four addresses,stores the device types, and addresses found,and Class B NACs can be converted to two Class A NACs with then loads default values for all options (General Alarm). It the NACKEY(included). also checks for two or more devices set to the same address. • Silence Inhibit and Auto Silence timer options. Online Editing: While still providing fire protection, the • Continuous, March Time, Temporal or California code for MS-9600LS/E may be programmed from the front panel. Sim- main circuit board NACs with two-stage capability. ple menu trees displayed on the LCD allow the trained user to • Selectable strobe synchronization per NAC. perform all functions without referring back to the programming • 3.0 amps maximum per each NAC circuit manual. Note: Maximum 24 VDC system power output is shared English Label Library: Quickly select labels from a standard among all NAC circuits and 24 VDC special application aux- library of more than 50 adjectives/nouns, such as "FLR 3 iliary power outputs. Total available output is 7.0 amps. HALLWAY," or enter custom labels letter-by-letter. Use recall ADVANCED FIRE TECHNOLOGY: function to repeat previously used label. • Sensitivity testing with printable results,onsite or offsite. Program Check: Automatically catch common errors, such as control modules not linked to any zone or input point. • Automatic drift compensation. PROGRAMMING AND SOFTWARE: Maintenance Alert • Autoprogram(learn mode)reduces installation time. The MS-9600LS(E) continuously monitors each smoke detec- • Fully programmable from local keypad, local PS/2 keyboard tor and is capable of reporting maintenance conditions. This or PC(using the standard PS-TOOLS Windows®utility). reduces the risk of false alarms due to dust accumulation. Two-level user programmable passwords. Refer to the control panel installation manual for more informa- • tion. • Custom English labels(per point)may be manually entered or selected from an internal library file. Automatic Test Operation • Three Form-C relay outputs(two programmable). • 99 software zones. The MS-9600LS(E)performs an automatic test of each detec- tor every two hours. Failure to meet the test limits causes an USER INTERFACE: AUTO TEST FAIL trouble type. System Reset clears this trou- • Optional plug-in DACT-UD2 communicator (standard with ble. MS-96000DLS(E)with USB port for local upload/download. • Remote Acknowledge,Silence, Reset and Drill via address Terminal Blocksable monitor modules, ACS Series annunciators, LCD-80F AC Power—TB1: 120 VAC, 60 Hz, 3.0 amps or 240 VAC, 50 remote annunciator, or ANN-80 Series Annunciators. Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with • EIA-232 printer/PC interface (variable baud rate) on main 600 V insulation. circuit board. Battery (lead acid only) — TB2: Maximum charging circuit: • Integral 80-character LCD display with backlighting. Normal flat charge 27.6 VDC @ 1.0 amp. Maximum battery • Real-time clock/calendar with automatic daylight savings charger capacity: 26 AH. Minimum battery 12 AH. MS- adjustments. 9600LS(E)cabinet holds maximum of two 18 AH batteries. For History file with 1,000 event capacity. 26—120 AH batteries, use the CHG-120F or CHG-75 Battery • Charger and BB-55F Battery Box. • EIA-485/ANN-BUS supporting up to 8 ANN Series Annunci- NOTE:Jumper JP3, on the FACP main circuit board, must be cut ators or 32 ACS Series annunciators. to disable the FACP battery charger when using the CHG-120F or • EIA-485 supporting up to 32 ACS annunciators. CHG-75. • Maintenance alert warns when smoke detector dust accu- Communication Loop — (standard) TB8: 24 VDC nominal, mulation is excessive. 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) • Automatic device type-code verification. total twisted, unshielded pair length. Maximum loop current: • One person audible or silent walk test with walk-test log and 400 mA (short circuit) or 100 mA (normal). Maximum loop printout, resistance:40 ohms. Supervised and power-limited. • Point trouble identification. Notification Appliance Circuits — TB4: Power-limited cir- • Local piezo sounder. cuitry. Nominal operating voltage: 24 VDC. Current limit:fuse- less, electronic, power-limited circuitry. Maximum signaling • Waterflow(nonsilenceable)selection per monitor point. current per circuit: 3.0 amps. End-of-Line Resistor: 4.7K ohm, • System alarm verification selection per detector point. 1/2 watt (P/N 71252 UL listed) for NACs. Refer to Fire•Lite • PAS (Positive Alarm Sequence) and presignal delay per Device Compatibility Document for listed compatible devices. point(NFPA 72 compliant). Page 2 of 6—df-60334:A4•12/29/2009 Programmable and Trouble Output Relays—TB5: Contact BB-26: Battery backbox,holds up to two 25 AH batteries. rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC CHG-120F: Remote battery charging system for lead-acid bat- (resistive). Form-C relays. teries with a rating of 25 to 120 AH. CHG-120F or CHG-75 Four-Wire Resettable Smoke Detector Power required for charging greater than 25 AH batteries. (24 VDC nominal)—TB3,Terminals 1(+)&2(—): CHG-75: Battery charger for lead-acid batteries with a rating Maximum ripple voltage: 10 mVRMs. Up to 1.5 amps for pow- of 25 to 75 AH. CHG-120F or CHG-75 required for charging ering four-wire smoke detectors. Power-limited circuit. Refer to greater than 25 AH batteries. Fire•Lite Device Compatibility Document for listed compatible devices. BAT Series: Batteries,see data sheet DF-52397. Nonresettable Power #1 (24 VDC Nominal) —TB3, Termi- PRT/PK-CABLE: Cable printer/personal computer interface nals 3(+) &4(—): Maximum ripple voltage: 10 mVRMs. Up to cable. 1.5 amps total DC current available from each output. Power- PRN-6F: UL listed compatible event printer which uses tractor- limited circuit. TB3, Terminals 5 (+) & 6 (—): non-resettable fed paper. power#2. Nonresettable Special Application Power#2(24 VDC Nom- Compatible Addressable Devices inal)-TB3, Terminals 5(+) &6(-): Maximum ripple voltage: 10mVRMS. Total DC current available from each output is up All feature a polling LED and rotary switches for addressing. to 1.5 amps. Power-limited circuit,nonsupervised. CP355:Addressable low-profile ionization smoke detector. EIA-485(ACS/ANN)—TB6: Annunciator connector, program- SD355:Addressable low-profile photoelectric smoke detector. mable for type ANN or ACS. Terminal 1 (+)and Terminal 2(—). SD355T:Addressable low-profile photoelectric smoke detector EIA-485(TERM)—TB7: Terminal mode annunciator connec- with thermal sensor. tor,Terminal 1 (Out+),2(In+),3(Out—),4(In—). H355: Fast-response, low-profile heat detector. EIA-232—TB8: PC/printer connector,Terminal 1 (Transmit),2 11355R: Fast-response, low-profile heat detector with rate-of- (Receive),3(DTR),4(Ground). rise option. Ordering Options H355HT: Fast-response, low-profile heat detector that acti- vates at190°F(88°C). MS-9600LS(E): 318-point addressable Fire Alarm Control AD355: Low-profile, intelligent, "Adapt" multi-sensor detector; Panel, one SLC loop. Includes 80-character LCD display, sin- B350LP base included. gle printed circuit board,and cabinet. MS-96000DLS(E): 318-point addressable Fire Alarm Control BEAM355: Intelligent beam smoke detector. Panel, one SLC loop. Includes DACT-UD2, 80-character LCD BEAM355S: Intelligent beam smoke detector with integral display,single printed circuit board,and cabinet. sensitivity test. DACT UD2: Optional communicator for remote monitoring D350PL: Photoelectric low-flow duct smoke detector. (standard with MS-96000DLS). D35ORPL: Photoelectric low-flow duct smoke detector with 4XTMF: Optional Transmitter Module provides a supervised relay option. output for local energy municipal box transmitter, alarm and MMF-300: Addressable Monitor Module for one zone of nor- trouble reverse polarity. It includes a disable switch and dis- mally-open dry-contact initiating devices. Mounts in standard able trouble. 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- IPDACT-2/2UD, IPDACT Internet Monitoring Module: line resistor. Module may be configured for either a Style B Mounts in bottom of enclosure with optional mounting kit(P/N: (Class B)or Style D(Class A) IDC. IPBRKT). Connects to primary and secondary DACT tele- MDF-300: Dual Monitor Module. Same as MMF-300 except it phone output ports for internet communications over customer provides two Style B(Class B)only IDCs. provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP MMF-301: Miniature version of MMF-300. Excludes LED and or static IP. (See data sheet DF-60407 or DF-52424 for addi- Style D option. Connects with wire pigtails. May mount in tional information. device backbox. IPBRKT: Optional mounting bracket kit consisting of screws MMF-302: Similar to MMF-300, but may monitor up to 20 con- and battery shield with standoffs required when mounting the ventional two-wire detectors. Requires resettable 24 VDC IPDACT in lower enclosure section of FACP. power. Consult factory for compatible smoke detectors. IPSPLT: Optional Y-Adaptor which allows connection of both CMF-300: Addressable Control Module for one Style Y/Z panel dialer outputs to one cable input to IPDACT (sold sepa- (Class B/A) zone of supervised polarized Notification Appli- rately). ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC ACM-8RF: Optional plug-in relay module provides 8 Form-C to power notification appliances. 5.0 amp relays. CRF-300: Addressable relay module containing two isolated PK-CD: Contains PS-TOOLS programming software for Win- sets of Form-C contacts, which operate as a DPDT switch. dows®-based PC computer(cable not included). Mounts directly to a 4.0" (10.16 cm.)box,surface mount using SLC-2LS: Optional expander module, enables second SLC the SMB500. loop. BG-12LX:Addressable manual pull station with interface mod- DP-9692: Optional dress panel for MS-9600LS(E). ule mounted inside. TR-CE: Optional Trim Ring for semi-flush mounting. 1300:This module isolates the SLC loop from short circuit con- BB-55F: Battery box, required to house two 25 AH batteries ditions(required for Style 6 or 7 operation). and one CHG-120F battery charger. For batteries greater than SMB500:Used to mount all modules except the MMF-301 and 25 AH,consult factory for housing/mounting arrangements. M301. df-60334:A4•12/29/2009—Page 3 of 6 Audio Control for ACC-25/50(ZSIT)Audio-Command-Center EIA-485 24 VDC INTERFACE DACT-UD2 (4-data wires, for Central Station reporting ...-o., 2-power wires) 10. DACT-UD2 (see photo detail below) .I�. L 4 0000 111 LCD-80F .... Up to 6,000 ft.(1825.8 m) .... ► between each LCD-80F I ir in the EIA-485 loop,and MS-ssoo�s SMOKE between each LCD-80F ""`""`°"`"°"""" DETECTORS and the FACP SD355,SD355T,CP355 bra��r4veu ms 0- EIA-485 Cj ACS/ANN-BUS MUMHEAT ANNUNCIATORS (2-data wires, DETECTORS 2-power wires) H355,H355R I 1 10F 8 FORM-C,5-AMP RELAYS REMO (optional,order ACM-8RF) I151�� ANN-80 ► R U I' NACs(Notification DUCT DETECTORS D350PL,D35ORPL Appliance Circuits) EIA-232 i0BELLS,SIGNALS,STROBES INTERFACE .• �'* •, ► INTELLIGENT _ � '" ‘1' BEAM DETECTORS PRINTER Optional /'t BEAM355, REVERSE BEAM355S POLARITY/ ' CITY BOX •, rt ^ OUTPUT 111 A , `d o . oh (4XTMF) c `J DACT-UD2 6 r• #I _g rij I �o�o o�oJ MONITOR ,I —A MMF-300,MDF-300, "; MMF-302,CMF-300, ( CRF-300,1300 4XTMF Reverse Polarity Module , I . 0. � 4i IA u ID 0 Ulm cJ • ®- B n n •11111 ■o■-- p MINI MONITOR MMF-301 IPDACT ,. ADDRESSABLE Internet Protocol DACT MULTI-MODULES MMF-300-10, MMF-302-6, CMF-300-6, CRF-300-6 FIRE 11 o, PULL STATION BG-12LX Page 4 of 6—df-60334:A4•12/29/2009 MMF-300-10: Ten-input monitor module. Mount one or two • modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. Compatible Annunciators ANN-80(-W): Remote LCD annunciator that mimics the infor- mation displayed on the FACP's LCD display. Recommended wire type is unshielded. (Basic model is red;order-W version for white; see DF-52417). ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure(see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points (see DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays (see DF- 52431). ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a Serial or Parallel printer(see DF-52429). ANN-I/O: I/O Driver Module provides connections to a user supplied graphic annunciator(see DF-52430). ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation.Available in increments of 16 or 32 points to meet a variety of applications. ACS-LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. TERM MODE LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 LCD- 80F annunciators may be connected to the EIA-485 terminal mode serial interface on the MS-9600LS(E)motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9600LS(E), see the following data sheets(docu- ment numbers) ACM-8RF (DF-51555), ACS/ACM Series (DF- 52378),LDM Series(OF-51384),LCD-80F(DF-52185). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. df-60334:A4•12/29/2009—Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Cabinet Specifications • Intelligent Signalling Line Circuits 1 expandable to 2 Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x • Intelligent detectors 159 per loop 0.67" (1.70 cm.) deep. Backbox: 19.00" (48.26 cm.) high x • Addressable monitor/control modules 159 per loop 16.65" (42.29 cm.) wide x 5.21" (13.23 cm.) deep. Trim Ring • Programmable software zones 99 (TR-CE):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • ANN-BUS devices 8 Shipping Specifications • ACS Annunciators 32 Dimensions: 20.00" (50.80 cm) high, 22.5" (57.15 cm) wide, • LCD Annunciators 32 8.5"(21.59 cm)deep. Weight: 27.3 lbs(12.38 kg). Electrical Specifications Temperature and Humidity Ranges • Primary input power: This system meets NFPA requirements for operation at 0 — 120 VAC,50/60 Hz,3.0 A. 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH 240 VAC,50 Hz, 1.5 A. (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the • Battery:27.6 VDC @ 1.0 A(max). useful life of the system's standby batteries and the electronic Maximum battery charger capacity:26 AH. components may be adversely affected by extreme tempera- Minimum battery: 12 AH. ture ranges and humidity. Therefore, it is recommended that MS-9600LS cabinet holds maximum of two 18 AH batteries. this system and its peripherals be installed in an environment • Communication Loop: 24 VDC nominal, supervised and with a normal room temperature of 15—27°C/60—80°F. power-limited. • Notification Appliance Circuits:terminal block provides con- Agency Listings and Approvals nections for four Style Y (Class B)or two Style Z(Class A) The listings and approvals below apply to the MS-9600LS(E) NACs. and MS-96000DLS(E) control panels. In some cases, certain Maximum signaling current per circuit:3.0 A. modules may not be listed by certain approval agencies,or list- End-of-Line Resistor: 4.7 K ohms, 1/2 watt (P/N 71252 UL ing may be in process.Consult factory for latest listing status. Supervised1per for Style Y(Class B)NAC. • ULC: S624(MS-9600LSC only;see DF-60438) and power-limited. Refer to panel documentation and Fire-Lite Device Compat- • FM APPROVED:to UL ANSI 864 ibility Document for listed compatible devices. • CSFM: 7170-0075:217 • Two Programmable Form-C Relays and One Fixed Trouble • MEA: 87-08-E Form-C Relay:Contact rating:2.0 A @ 30 VDC(resistive) 0.5 A @ 30 VAC(resistive). NFPA Standards • Four-wire Resettable Special Application Power (24 VDC nominal): Up to 1.5 A for powering four-wire smoke detec- The MS-9600LS(E) and MS-96000DLS(E) control panels tors. Power-Limited, nonsupervised. comply with the following NFPA 72 Fire Alarm Systems Refer to Fire-Lite Device Compatibility Document for listed requirements: compatible devices. —LOCAL (Automatic, Manual, Waterflow and Sprinkler • Nonresettable Special Application Power#1 (24VDC nomi- Supervisory). nal)TB3,Terminals 3(+)&4(-): —AUXILIARY(Automatic, Manual and Waterflow) (requires Maximum ripple voltage: 10 mVRMs 4XTMF). Total DC current available from each output is up to 1.5 A. —REMOTE STATION (Automatic, Manual and Waterflow) Power-limited, nonsupervised. (Requires 4XTMF where DACT-UD2 is not accepted.) • Nonresettable Special Application Power#2 (24VDC nomi- —PROPRIETARY(Automatic, Manual and Waterflow). nal)TB3,Terminals 5(+)&6(-): Maximum ripple voltage: 10 mVRMs —CENTRAL STATION (Automatic, Manual and Waterflow, Total DC current available from each output is up to 1.5 A. and Sprinkler Supervised). Power-limited, nonsupervised. —OT(Other Technologies-PSDN) For use with IPDACT. NOTE: Although each Special Application power output can deliver 1.5 A individually, the total power output from these circuits cannot exceed 1.5 A in standby. The total Alarm output for all Spe- cial Application power and NAC circuits cannot exceed 7 A. LiteSpeedTM is a trademark;and FireLite®Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 900 is document is not intended to be used for installation purposes. e try to keep our product information up-to-date and accurate. CIEFITIFIEED EN N EUNC IF MANUFACIUW e cannot cover all specific applications or anticipate all requirements. QUALITY SYSTEM!specifications are subject to change without notice. Made in the U.S.A. For more information,contact Fire•Lite Alarms. Phone: (800)627-3473, FAX:(877)699-4105. Page 6 of 6—df-60334:A4•12/29/2009 • Honeywell Fire Alarm Communicators THE POWER OF CONNECTED IPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel(FACP)that has a built-in dialer.This single or dual path communicator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communicator Transmitter (DACT).It offers three selectable reporting paths which include:Cellular only,IP only, or IP primary/cellular backup.All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet°Network Control Center,which routes highly encrypted IPG -4G Commercial p,.Cmnnwnk.tor Ethernet data packets via a customer provided internet connection or cellular network ■ ,.•,� to the appropriate central station.The state of the art AlarmNet network control center ■LOW..n is fully redundant and monitored 24/7.AlarmNet has the ability to route messages Vas using AlarmNet-I and 800 PLUS services,providing true redundancy and multi-path message delivery. Alternative communication methods are critical in the marketplace due to VoI P(Voice over IP),migration from POTS(Plain Old Telephone Service)and growth of digital radio networks.The IPGSM-4G's single path communications solution allows one technology to be used(either IP or cellular)to provide the appropriate connectivity to a central station.For added reliability,our exclusive dual path solution allows both technologies(IP and cellular)to be used together for maximum survivability or for local jurisdiction requirements that specify a dual technology system. FEA I URES & BENFFIIS • Saves the cost of two • Operates over the • Works over any type of Private Static IP • ()OS:Quality of Service dedicated phone tines. following customer provided addressing. diagnostics via communication Ethernet 10/100 based AlarmNet conveys vital • Single or dual path protocols:HSPA+(4G) network connection • Built-In Power Supply communicator communications-(can HSPA(HSDPA& (LAN or WAN),DSL module:On board information including communicate to HSUPA)(3G),EDGE modem or cable charging circuit design when message was central station using (2G GPRS)(2G). modem. accommodates back- received,signal cellular technology, up battery.Includes strength,and message internet,or both. • Selectable reporting • Data transmits over primary power and path used. paths and supervision standard contact-ID battery supervision. p • Requires no change to intervals to meet NFPA protocol but is secured • 7720P Hand-held the existing Fire Alarm 72,chapter 26 with the industry's • Diagnostic LEDs: programmer for easy Control Panel requirements. advanced encryption Signal strength and setup. configuration. (Compliant with NFPA standard(AES 256 bit). status indicators. (Connects directly to 72 2010 and 2013 the primary and supervision • Supports both dynamic • Reliable connection:IP secondary telephone requirements.) (DHCP)or Public and and GSM connection ports of a DACT.) tested every day. The IPGSM-4G is designed to operate over the most • Primary City ID(two digits)obtained from your common cellular networks,including 3G and HSPA+. monitoring station. Its multi GSM platform technology automatically • Primary CentralStation ID(two digits)obtained from chooses the best available cellular signal in the area your monitoring station. based on signal strength and seamlessly self-adjusts to maintain critical life safety communication.In • Primary Subscriber ID(four digits)obtained from addition,it connects to any type of customer provided your monitoring station. Ethernet 10/100 base network connection(LAN or • Communication Module's MAC ID,and MAC CRC WAN),DSL model or cable modem.Our selectable number located on outside of box,and inside of the reporting path feature allows the radio to be module. configured for a single or dual path solution as well as All of these parameters are assigned by the monitoring the appropriate supervision intervals based on NFPA station. 72 requirements.(See diagram below for selectable paths and supervision timing intervals.) Note:Some assembly is required.See Installation and Setup Guide #800-12454 for full details. Selectable Path Description Supervision Times Fire Communicator Capability 2010 GSM Single Path(cellular only) 5 minutes The IPGSM-4G is compatible with fire panels that use 2010 IP Single Path(IP only) 5 minutes the Contact ID communications format as described in 2010IP&GSM Dual Path(IP and cellular) 24 hours the SIA DC 05 standard. 2013 GSM Single Path(cellular only) 1 hour AlarmNet 2013 IP Single Path(IP only) 1 hour Honeywell's AlarmNet has been the nationwide leader 2013 IP&GSM Dual Path(IP and cellular) 6 hours in alarm communications technology since 1986.A reliable alternative for the transmission of alarm • Operation signals,our radio network provides extensive coverage When an event occurs,the Fire Alarm Control Panel in the United States and Canada.AlarmNet Network goes off hookto dialthe central station.The IPGSM-4G Control center processes signals from powerful servers Dialer Capture Module detects the off-hook condition in multiple locations equipped with 24/7 and provides the fire panel with a dial tone.When the infrastructure support.The AlarmNet network consist fire panel detects the dial tone,it begins dialing the of redundant hardware servers,hot back-up databases central station.After the dialing is completed,the and generators with battery back-up at all locations to Dialer Capture Module returns a handshake to the fire ensure continuity of service.Signals from Alarm-Net panel.The fire panel then sends the contact ID reports are transmitted to the central station's receivers using to the Dialer Capture Module,which in turn sends a multiple communications paths consisting of the kiss-off after the report is successfully received from Internet,radio network or toll-free POTS service. the fire panel.The Dialer Capture Module sends the contact ID reports to the IPGSM communications Installation Requirements module.When all the reports are sent,the fire panel UL COMPLIANCE goes on-hook.The IPGSM communications module To meet UL864/NFPA,ensure the following: then transmits the messages to the central station either over the GSM network or the Internet • IPGSM-4G must be installed in accordance with (dependent on configuration). NFPA(National Fire Protection Association) Easy to Program standards 70 and 72. The IPGSM 4G communicator can be pre • IPGSM-4G must be mounted in the same room and programmed using the 7720P programmer to enter all within 20 feet of the fire panel. central-station information.This is saved to the • IPGSM-4G,and all equipment used for the IP IPGSM 4G communicator panel memory.When the connection(such as the router,hub,modem,etc.) IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet,it registers itself shall be listed,must be powered from an un with the AlarmNet receiver. switched branch circuit,and be provided with appropriate standby power. For most installations,the only required parameters • IPGSM-4G must use the 7AH battery(not supplied) are: to provide 24-hour backup capability. 2 . IPGSM-4G Technical Specifications ELECTRICAL PRODUCT LINE INFORMATION Ademco®and AlarmNet®are registered trademarks of Transformer: IPGSM-4G: Internet and Digital Cellular Fire Alarm Honeywell International Inc. Primary: 120VAC,60Hz,0.5A Communicator Panel.Includes red cabinet with Ademco° Secondary: 18VDC,50VA key and lock,wall outlet box,Dialer Capture Module,IGSM This document is not intended Communications Module,antenna&mounting adapter, to be used for installation Battery: purposes.We try to keep our PowerBoostl power supply,LED display board, product information up-to- One 12 V 7.0 AH lead-acid battery:(not supplied) transformer,manual,&required screws,cables,etc. date and accurate.We cannot Battery charging current: 1 Amp maximum Antenna External Hardware cover all specific applications Battery discharge current: Standby 230mA,Active GSM-ANT3DB: 3db gain external/remote antenna or anticipate all requirements. 950mA All specifications are subjectto WA7626-CA: SNA to N Adapter change without notice. CABINET SPECIFICATIONS 7626-50HC: 50 ft.antenna cable,low toss Dimensions: 14.875"H x 12.75"W x 3.0"D(37.8 cm H 7626-25HC: 25 ft.antenna cable,low loss x 32.4 cm W x 7.6 cm D) Note:The GSM-ANT3DB and the WA7626-CA are both required for Color: Red installing an external antenna along with the necessary cable needed (7626-50HC:50 ft.or 7626-25HC:25 ft.) SHIPPING SPECIFICATIONS Weight: 5.3 lbs.(6.94 kg) Other Accessories Dimensions: 15.625"H x 13.79"Wx 9.25"D(39.7 cm H 7720P: IPGSM 4G hand held programmer. x 34.9 cm W x 23.9 cm 0) HPTCOVER: Plug-in transformer box for I PGSM communicator. TEMPERATURE AND HUMIDITY RANGES BAT-1270: Battery 12 Volts,7 AH,sealed. This system meets NFPA requirements for operation at 0- AGENCY LISTINGS AND APPROVALS 49°C/32-120°F and at a relative humidity 93°/o±2°/o RH (non condensing at 32°C±2°C(90°F±3°F).However,the The listings and approvals below apply to the basic useful life of the system's standby batteries and the IPGSM-4G communicator panel.In some cases,certain electronic components may be adversely affected by modules may not be listed by certain approval agencies, extreme temperature ranges and humidity.Therefore,it is or listing may be in process. recommended that this system and its peripherals be Consult factory for latest listing status. installed in an environment with a normal room UL Listed: S789 temperature of 15-27°C/60-80°F. CSFM:7300-1645:0199 FDNY:COA#6219 For more information Learn more about Honeywell's IPGSM-4G and other products available by visiting www.honeywellpower.com. Honeywell Power Products 12 Clintonville Road Northford,CT 06472-1610 877.HPP.POWR Honeywell DH-60769 I F 106/17 www.honeywell.com ©2017 Honeywell International Inc. THE POWER OF CONNECTED DF-52384:D•E-160 • SD355(A) Series FIre•LITeAtarms Addressable Photoelectric Smoke Detectors by Honeywell MEM Allii, MIMEM. Addressable Devices General The SD355(A), SD355T(A), and SD355R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Addressable Fire Alarm Control Panels (FACPs). The SD355T(A)adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are 0 addressable, they will help emergency personnel quickly W locate a fire during its early stages,potentially saving precious 4NW t m' rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indica- tion. Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The SD355R(A) is a SD355(A) in B210LP(A) Base remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features OPTIONS • Remote LED output connection, PN RA100Z(A). SLC LOOP • Two-wire loop connection. Applications • Unit uses base for wiring. Use photoelectric detectors in life-safety applications to pro- ADDRESSING vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often • Addressable by device. better than photoelectric detectors at sensing fast, flaming • Rotary, decimal addressing: 01 —99 with MS-92000D(LS), fires. and 01 —159 with MS-96000D(LS). ARCHITECTURE Construction • Unique single-source, dual-chamber design to respond These detectors are constructed of off-white fire resistant plas- quickly and dependably to a broad range of fires. tic. SD355(A) series plug-in, low-profile smoke detectors are Sleek,low profile design. designed to commercial standards and offer an attractive • appearance. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. Installation • Removable cover and insect resistant screen for simple SD355(A)series plug-in detectors use a detachable mounting field cleaning. base to simplify installation,service and maintenance. OPERATION Mount base (all base types)on an electrical backbox which is • Withstands air velocities up to 4,000 feet-per-minute(20 m/ at least 1.5"(3.81 cm)deep. For a chart of compatible junction sec.)without triggering a false alarm. boxes,see DF-60059. • Factory preset at 1.5% nominal sensitivity for panel alarm NOTE:Because of the inherent supervision provided by the SLC threshold level. loop, end-of-line resistors are not required. Wiring `T-taps" or • Visible LED"blinks"when the unit is addressed (commun• branches are permitted for Style 4 (Class B) wiring. SD355R(A) Gating with the fire panel)and latches on in alarm. mounts in a D355PL(A)or DNR(AyDNRW duct detector housing. MECHANICALS Operation • Sealed against back pressure. Each SD355(A) series detector uses one of 99 ( ) possible • Direct surface mounting or electrical box mounting. addresses on the MS-92000D(LS) and up to 318 (159 on • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 each loop) on the MS-96000D(LS) Signaling Line Circuit cm)octagonal box,or 4.0"(10.16 cm)square electrical box (SLC).It responds to regular polls from the system and reports (using a plaster ring—included). its type and status. OTHER SYSTEM FEATURES The addressable photoelectric sensor in the SD355(A) series has a unique unipolar chamber that responds quickly and uni- • Fully coated circuit boards and superior RF/transient pro- formly to a broad range of smoke conditions. It can withstand tection. wind gusts up to 4,000 feet-per-minute (20 m/sec.) without • 94-VO plastic flammability rating. sending an alarm level signal. Because of its unipolar Cham- • Low standby current. ber, the SD355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DF-52384:D•2/11/2015—Page 1 of 2 Detector Sensitivity Test SD355RA: Same as SD355R with ULC Listing for use with a • D355PLA or DNRA duct detector housing; B210LPA base Each detector can have its sensitivity tested (required per included. NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-92000D(LS) or MS- INTELLIGENT BASES 96000D(LS) addressable fire alarm control panel. The results NOTE:"A"suffix indicates ULC Listed model. of the sensitivity test can be printed off the MS-92000D(LS)or MS-96000D(LS)for record keeping. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing,see DF-60059. Specification B210LP(A): Plug-in detector base (included); standard U.S. Voltage range: 15—32 VDC(peak). flanged low-profile mounting base. Standby current:300 pA @ 24 VDC. B210LPBP: Bulk pack of B210LP;package contains 10. LED current: 6.5 mA @ 24 VDC(latched"ON"). B501(A): Standard European flangeless mounting base. Air velocity: 4,000 ft./min. (20 nn/sec.)maximum. B501 BP: Bulk pack of B501;package contains 10. Size:2.1" (5.33 cm) high;base determines diameter. B200SR(A): Intelligent sounder base capable of producing —B210LP(A):6.1" (15.5 cm)diameter. sound output with ANSI Temporal 3 or continuous tone. —B501(A):4.1"(10.4 cm)diameter. Replaces B501 BH series bases in retrofit applications. -B200SR(A): 6.875" (17.46 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals:up to 14 AWG(2.0 mm2). Relay type: Form-C.Rating:2.0 —B224RB(A):6.2"(15.748 cm)diameter. A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ Weight: 3.6 oz. (102 g). 30 VDC inductive. Operating temperature range: for SD355(A): 0°C to 49°C B224BI(A): Plug-in System Sensor isolator detector base. (32°F to 120°F); for SD355T(A):0°C to 38°C(32°F to 100°F). Maximum 25 devices between isolator bases(see DF-52389). SD355R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F to 158°F). ACCESSORIES Temperature:0°C—49°C(32°F—120°F). F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high-profile bases to Relative humidity: 10%—93%, non-condensing. low-profile. Listings F110BP: Bulk pack of F110;package contains 15. Listings and approvals below apply to the SD355(A), F210: Replacement flange for B210LP(A)base. SD355T(A), and SD355RT(A) detectors. In some cases, cer- RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to tain modules may not be listed by certain approval agencies, a U.S. single-gang electrical box. For use with B501(A) and or listing may be in process. Consult factory for latest listing B210LP(A)bases only. status. SMB600:Surface mounting kit • UL Listed:S1059. M02-04-00:Test magnet. • ULC Listed: S1059. M02-09-00:Test magnet with telescoping handle. • CSFM:7272-0075:0194. XR2B: Detector removal tool. Allows installation and/or • MEA:243-02-E. removal of detector heads from bases in high ceiling applica- • FM approved. tions. XP-4: Extension pole for XR2B. Comes in three 5-foot Product Line Information (1.524 m)sections. NOTE:"A"suffix indicates ULC Listed model. T55-127-010: Detector removal tool without pole. SD355: Addressable photoelectric detector; B210LP base BCK-200B: Black detector covers for use with SD355(A)only; included. box of 10. SD355A: Sames as SD355 with ULC Listing; B210LPA base WCK-200B: White detector covers for use with SD355(A) included. only;box of 10. SD355T: Same as SD355 but with thermal element; B210LP base included. SD355TA: Same as SD355T with ULC Listing; B210LPA base included. SD355R: Remote test capable addressable photoelectric FireLite®Alarms is a registered trademark of Honeywell International Inc. detector for use with a D355PL(A) or DNRA/DNRW duct ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use detector housing; B210LP base included. of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. CERT IF U E D We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52384:D•2/11/2015 DF-52013:D•E-100 BG-12LX FIre•Lrre-Alarms Addressable Manual Pull Station by Honeywell 111111ff .. Addressable Devices General The Fire•Lite BG-12LX is a state-of-the-art, dual-action (i.e., ;z E requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire•Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the alarm. Features PUSH IN • Maintenance personnel can open station for inspection and PULL DOWN address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to ®Fre a re'�a�arms Z SLC loop(accepts up to 12 AWG/3.25 mm2 wire). by Honeywell I • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4" (10.16 cm)square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- LL lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish. double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate mg the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — • Shipping Weight: 9.6 oz. (272.15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 pA. Specifications • Maximum SLC alarm current: 5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- appear instructions provided on the cover. The word FIRE shall gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1.00 inches will surface mount to the model SB-10 or SB-I/O surface back- (2.54 cm) or larger. Stations shall be suitable for surface box. If the BG-12LX is being semi flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single gang, double gang, or 4" (10.16 cm) square electrical box, and shall be installed DF-52013:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O:Surface backbox;plastic. BG12TR: Optional trim ring. 17003: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UUULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite®Alarms®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. =� C E R T I F l E[! We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52013:D•4/13/2012 DF-52121:E•E-325 MMF-300(A) Series, MDF-300 Flre•uTGALarms Addressable Monitor Modules by Honeywell Addressable Devices General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor oni for modules are used to supervise a circuit of dry-contact input e devices,such as conventional heat detectors and pull stations, �t or monitor and power a circuit of two-wire smoke detectors .- (MMF-302(A)). STATION AKAII„ 11/11144‘11 ALARM MMF-300(A)is a standard-sized module(typically mounts to a ! 4" [10.16 cm] square box) that supervises either a Style D • x, (Class A) or Style B (Class B) circuit of dry-contact input devices. ALL CIRCUITS ARE POWER 1.041ULI MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 f (.) zArt -40 cm) H x 2.75" (6.985 cm)W x 0.65" (1.651 cm) D that super- " „ ' vises a Style B(Class B)circuit ofdry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B) or Style D(Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol developed by (provided)terminates the Style B circuit. No resistor is required Fire•Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other communication protocols. mal/short) of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF-300(A)SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC. power required. Maximum current draw:5.0 mA(LED on). • High noise(EMF/RFI)immunity. Average operating current: 375 pA (LED flashing), 1 corn- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. panels, 01 —99 on other compatible systems. • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts. to indicate alarm. EOL resistance:47K Ohms. The MMF-300(A) Monitor Module is intended for use in intelli- Temperature range:32°F to 120°F(0°C to 49°C). gent, two-wire systems, where the individual address of each Humidity range: 10%to 93%noncondensing. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Device Circuit (IDC) for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices. The module has a panel-controlled LED 2.125"(5.398 cm)deep box. indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-301(A) Mini Monitor Module MMF-300(A)APPLICATIONS • Built-in type identification automatically identifies this device Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. fire alarm pull stations, waterflow devices, or other normally- • Powered directly by two-wire SLC loop. No additional open dry-contact alarm activation devices. May also be used power required. to monitor normally-open supervisory devices with special • High noise(EMF/RFI)immunity. DF-52121:E•07/30/2015—Page 1 of 4 • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 — 159 on MS-9600 series source. panels, 01 —99 on other compatible systems • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 1415 0 1 ADDRESS 0 1 • Direct-dial entry entry of address: 01 — 159 on MS-9600 1302 series panels, 01 —99 on other compatible systems. 3 �� 4 LOOP •D23 • LED flashes during normal operation. • LED latches steady to indicate alarm on command from 15 5 control panel. 9 8 7 6 • con 9 8 7 6 TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- ►I igent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional Lu detectors back to the control panel. All two-wire detectors -J 0 j Cr m being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302(A)APPLICATIONS I I I I Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B(Class B)or Style D(Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A) modules in MMF-302(A) OPERATION existing systems. Each MMF-302(A) uses one of the available module MMF-301(A)APPLICATIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC). A flashing LED detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control or other normally-open dry-contact devices. May also be used panel. The LED latches steady on alarm (subject to current to monitor normally-open supervisory devices with special limitations on the loop). supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B(Class B) Initiating Device MMF-302(A)SPECIFICATIONS Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. the circuit. Maximum current draw:5.1 mA(LED on). MMF-301(A) OPERATION Maximum IDC wiring resistance: 25 Ohms. Each MMF-301(A) uses one of the available module Average operating current: 270 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds, 3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K Ohms. MMF-301(A)SPECIFICATIONS External supply voltage(between Terminals T10 and T11): Nominal operating voltage: 15 to 32 VDC. • DC voltage:24 volts power limited. Average operating current: 350 pA, 1 communication every • Ripple voltage: 0.1 Vrms maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC • Current: 90 mA per module maximum. Shorted). Temperature range:32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Current:450 pA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. EOL resistance:47K Ohms. Temperature range:32°F to 120°F(0°C to 49°C). MDF-300(A) Dual Monitor Module Humidity range: 10%to 93%noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two- 0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire Wire length:6"(15.24 cm)minimum. alarm and supervisory devices. The module has a single panel- controlled LED. MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. Page 2 of 4—DF-52121:E•07/30/2015 NOTE: The MDF-300(A)provides two Style 8 (Class 8) IDC cir- MDF-300(A): Monitor module, dual, two independent Class B cults ONLY. Style D (Class A) IDC circuits are NOT supported in circuits. any application. SMB500: Optional surface-mount backbox. MDF-300(A)SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Wiring Normal operating voltage range: 15 to 32 VDC. Manual, PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current:750 pA(LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range: 32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. MDF-300(A)AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4"(10.16 cm)square, 2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424. • ULC: S2424. • FM Approved. • CSFM:7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE:A"suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module,two-wire detectors. DF-52121:E•07/30/2015—Page 3 of 4 Fire Lite®is a registered trademark and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Iso ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF E We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52121:E•07/30/2015 *Th, SYSTEM SENSOR' Outdoor Selectable- Output Horns, 11 Strobes, and Horn Strobes for Wall Applications SPECTIIert SpectrAlerl®Advance outdoor audible visible products A o v ,ea N c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill ® si i holes for screw-in mounting. Plastic and metal weatherproof back ® MEA 7300 165 boxes come with 3/4 inch top and bottom conduit entries and 3/4 inch 7300-1653-187:187(outdoor strobes) 7125-1653:188(horn strobes, knock-outs at the back.A screw-in NPT plugwith an 0-ringgasket S4011(chimes,horn strobes,horns) APPROVED approved chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17, and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams 14 4.7" 2.5' ` '. ,,---.=.==., / —, 5.6” ill) / 1111 if 10.3"F.'Mb-- iS' 7._. ,, (., \ ($4 , 4'6'111 —ii"----------______ ,.r z., .,u,:='===il ''3 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box 4 0 ir - if i)#?! '5)r��� . .1 j�t111 = �I --41111111.0 Hyl, Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd, Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd, Red,Outdoor(includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd, Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High Cd, Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard 0d,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*f Strobe, High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn, Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. (\�--"- SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Viisa systemsensorcom '_ SENSOR„ Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest\Jerson of this data sheet. AvoS01201•3/12