Report (83)
C6Northwest Fire Suppression, Inc. EQUIPMENT LIST ITEM MODEL DESCRIPTION 1 NFW-50 Addressable Fire Alarm Control Panel 2 IPGSM-4G Commercial Fire Alarm Communicator 3 NP-100 Addressable Smoke Detector 4 NOT-BG12LX Addressable Manual Station 5 NDM-100 Addressable Dual Point Monitor Module 7 P2RK Outdoor Horn strobe With Back Box 1800 NW 169t Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.com CCB#088629 Licensed • Bonded • Insured DN-7102:E FireWarden-50(E) NOTIFIER° Intelligent Addressable FACP with Built-In Communicator by Honeywell Addressable Fire Alarm Control Panels General The NOTIFIER FireWarden-50(NFW-50)is a Fire Alarm Con- trol Panel(FACP)and Digital Alarm Communicator/Transmitter (DACT)combined into one circuit board.This compact, intelli- gent addressable control panel supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the FireWarden-50 pro- grams just like FireWarden-100 products, yet fits into applica- tions previously served only by conventional panels. The FireWarden-50's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/Download utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network.Any personal computer with Windows''95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Upload/Download software, may serve as a Ser- vice Terminal. This allows download of the entire program or upload of the entire program, history file, walk-test data, cur- • Point trouble identification. rent status and system voltages. • Waterflow selection per module point. The power supply and all electronics are contained on a single • Alarm verification selection per detector point. circuit board supported on a new quick install chassis and • Maintenance alert warns when smoke detector dust accu- housed in a metal cabinet.Available accessories include local mulation is excessive. and remote upload/download software, remote annunciators, • One-person audible or silent walk test with walk-test log and reverse polarity/city box transmitter. (4XTM) and printout. The FireWatch Series internet monitoring modules IPDACT-2 • System alarm verification selection per detector point. and IPDACT-2UD permit monitoring of alarm signals over the • PAS (Positive Alarm Sequence) and Pre-signal per point Internet, saving the monthly cost of two telephone lines. (NFPA 72 compliant). Although not required, the secondary telephone line may be • Up to eight ANN-BUS annunciators retained providing backup communication over the public • Remote Acknowledge, Alarm Silence, Reset and Drill via switched telephone line. addressable modules or remote annunciator. NOTE: Unless otherwise specified, the term FireWarden-50 is • Upload/Download(local or remote)of program and data via used in this data sheet to refer to both the FireWarden-50 and the integral DACT. FireWarden-50E FACPs. For FireWarden-50C, refer to DN- 60446. SLC COMMUNICATION LOOP • Single addressable SLC loop which meets NFPA Style 4, 6 Features and 7 requirements. • Listed to UL Standard 864,9th edition. • 50 addressable device capacity (any combination of • Auto-program (learn mode) reduces installation time. addressable detectors and modules). Reports two devices set to the same address. • Compatible with NOTIFIER FireWarden addressable • On board DACT. devices(refer to the FireWarden SLC Wiring Manual). • Two independently programmable Style Z(Class A)or Style NOTIFICATION APPLIANCE CIRCUITS(NACS) Y(Class B)NAC circuits. • Two independently programmable output circuits. Circuits • Selectable strobe synchronization for System Sensor, can be configured for the following outputs: Wheelock,and Gentex devices. —Style Y(Class B) • Remote Acknowledge,Silence,Reset and Drill via address- —Style Z(Class A) able monitor modules. • Two programmable relays and one fixed trouble relay. —Door Holder Service(cannot be used for notification appliances) • Built-in Programmer. —Aux Power Source(cannot be used for notification appliances) • Telephone Line Active LEDs. • Silence Inhibit and Autosilence timer options. • EIA-232 PC interface. • Continuous, March Time, Temporal or California code for • Integral 80-character LCD display with backlighting. main circuit board NACs with two-stage capability. • Real-time clock/calendar with automatic daylight savings • Selectable strobe synchronization per NAC. control. • 2.5 A total power for NACs. • History file with 500 event capacity. NOTE:Maximum or total 24VDC system power shared between • Automatic detector sensitivity testing(NFPA 72 compliant). all NAC circuits and the ANN BUS is 2.7 A. • Automatic device type-code verification. DN-7102:E•02/22/2011—Page 1 of 4 PROGRAMMING AND SOFTWARE • Autoprogram(learn mode) reduces installation time. • Custom English labels(per point)may be manually entered or selected from an internal library file. • Two programmable Form-C relay outputs. • 20 software zones. • Continuous fire protection during online programming at the front panel. NFW-50 • Program Check automatically catches common errors not Fire Alarm _ linked to any zone or input point. Control Panel E • OFFLINE PROGRAMMING: Create the entire program in your office using PS-Tools, Windows®-based software N-ANN-80 package, and upload/download system programming locally. PS-Tools is available on www.magni-fire.com. _N-ANN-S/PG NP-100 Printer Gateway User interface Photo Detector LED INDICATORS N ANN 10 • AC Power(green Graphic LED (9 ) Module • Fire Alarm(red) • Supervisory(yellow) NI-100 • Trouble(yellow) Ionization Detector N-ANN-LED • Alarm Silenced signals(yellow) KEYPAD N-ANN-RLY • 16 key alpha-numeric pad NH-100 Series Relay Module • Acknowledge/Step Heat Detector • Alarm Silenced 1 F • Drill(Manual Evacuate) • Reset(lamp test) NDM-100 Strobe Product Line Information Dual Monitor Module NFW-50: Combination DACT/Fire Alarm Control Panel with one SLC loop.Includes main circuit board with display,chassis r ' with transformer, backbox with door, plastic bag containing j ' screws,cables, key,etc., manual. (For NFW-50C, refer to DN- P2R 60446.) NP-100T,NP-Al 00 Strobe Photo/Thermal Power Supply NFW-50E:Same as NFW-50,but operates at 240 VAC. FCPS-24S6 NFW-50R:Same as NFW-50,with red backbox and door. FCPS-2458 DP-51050B:Optional dress panel for NFW-50(black). NMM 100 P2R DP-51050:Optional dress panel for the NFW-50R(red). Monitor Module Strobe TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red,order TR-CE.) Sok NZM-100-6, BB XP:Optional cabinet for one or two modules. Multiple-Circuit r NMMBB-25: Optional cabinet for up to six modules mounted on NZM-100 Interface Module CHS-6 chassis. Monitor2-onio Detector Module BB-26: Batterybackbox, holds upto two 25 AH batteries and Module CHG-75. " NFS-LBB: Battery box,houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 DNR cabinet. Duct Detector CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. FIRE NFW-50 CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- ADDRESSABLE FIRE ALARM LBB for mounting. NOT-BG12LX CONTROL PANEL NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. Addressable Manual Pull Station BAT Series: Batteries,see data sheet DN-6933. Page 2 of 4—DN-7102:E•02/22/2011 PRT/PK-CABLE: Cable printer/personal computer interface DNR: InnovairFlex low-flow non-relay duct-detector housing. cable. (Order NP-100R separately.) PRN-6: UL listed compatible event printer. Uses tractor-fed DNRW: InnovairFlex low-flow non-relay duct-detector housing, paper. with NEMA-4 rating. Watertight.(Order NP-100R separately.) IPDACT, IPDACT-2/2UD Internet Monitoring Module: NMM-100: Addressable Monitor Module for one zone of nor- Mounts in bottom of enclosure with optional mounting kit (PN mally-open dry-contact initiating devices. Mounts in standard IPBRKT). Connects to primary and secondary DACT tele- 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- phone output ports for internet communications over customer line resistor. Module may be configured for either a Style B provided ethernet internet connection. Requires compatible (Class B)or Style D(Class A) IDC. Teldat Visoralarm Central Station Receiver.Can use DHCP or NDM-100: Dual Monitor Module.Same as NMM-100 except it static P.(See data sheet dn-60408 for more information.) provides two Style B(Class B)only IDCs. IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. NMM-100P: Miniature version of NMM-100. Excludes LED IPSPLT: Y-adaptor option allows connection of both panel and Style D option. Connects with wire pigtails. May mount in dialer outputs to one IPDACT-2/2UD cable input. device backbox. AC-TRMBLK:AC Terminal Block mounts to a metal bracket,in NZM-100A: Similar to NMM-100A.Addressable Monitor Mod- turn, mounts to the FACP chassis. Use AC-TRMBLK when ule for one zone of conventional two-wire detectors. Requires wire nuts are not allowed for AC connections to the trans- resettable 24 VDC power. Refer to the Device Compatibility former. Document for listed compatible devices and quantity limita- tion. OPTIONAL MODULES NZM-100-6: Six-zone interface module. Mount one or two 4XTM Reverse Polarity Transmitter Module: Provides a modules in a BB-XP cabinet (optional). Mount up to six mod- supervised output for local energy municipal box transmitter, ules on a CHS-6 chassis in a BB-25 cabinet. alarm and trouble. Includes a disable switch and disable trou- ble LED. NMM-100-10: Ten-input monitor module. Mount one or two ANN-SEC: Optional secondary ANN BUS interface module. modules in a BB-2 cabinet(optional).Mount up to six modules Note:Used only with firmware 3.0 or higher. on a CHS-6 chassis in a BB 25 cabinet. NC-100:Addressable Control Module for one Style Y/Z(Class COMPATIBLE ANNUNCIATORS B/A) zone of supervised polarized Notification Appliances. N-ANN-80(-W): Remote LCD annunciator mimics the informa- Mounts directly to a 4.0"(10.16 cm.)electrical box.Notification tion displayed on the FACP LCD display. Recommended wire Appliance Circuit option requires external 24 VDC to power type is un-shielded. (Basic model is black; order-W for white; notification appliances. see DN-7114.) NC-100R: Addressable relay module containing two isolated N-ANN-I/O: LED Driver Module provides connections to a sets of Form-C contacts, which operate as a DPDT switch. user supplied graphic annunciator.(See DN-7105.) Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red NOT-BG12LX: Addressable manual pull station with interface enclosure. (See DN-60242.) module mounted inside. N-ANN-RLED: Provides alarm (red) indicators for up to 30 N100-ISO: Fault Isolator Module. input zones or addressable points. (See DN-60242.) SMB500:Used to mount all modules except the NMM-100P. N-ANN-RLY: Relay Module provides 10 programmable Form- NOTE:For more information on Compatible Addressable Devices C relays. Can be mounted inside the cabinet.(See DN-7107.) for use with the FireWarden-50, see the following data sheets N-ANN-S/PG: Serial/Parallel Printer Gateway module pro- 6995), N1t100 (DN-)6 96),0 NH--1(00/NH-100R (DN6997),sDNN- R/ vides a connection for a serial or parallel printer. (See DN- InnovairFlex(DN-60424, DN-60429), NP-A100(DN-6998), NMM- 7103.) 100/NMM-100P/NDM-100/NZM-100 (DN-6999), NC-100 (DN- ADDRESSABLE DEVICES 7000), NC-100R(DN-60383), NMM-100-10(DN-6990), and NOT BG12LX(DN-7001). All feature a polling LED and rotary switches for addressing. NI-100:Addressable low-profile ionization smoke detector. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The NP-100:Addressable low-profile photoelectric smoke detector. 47k ohm assembly supervises the NMM-100-10, NDM-100, NP-100T: Addressable low-profile photoelectric smoke detec- NMM-100P, and NC-100 module circuits. The 3.9k ohm tor with thermal sensor. assembly supervises the NZM-100-6 module circuit. These NP-100R: Remote test capable addressable photoelectric resistors are included with each module. smoke detector for use with DNR(W)duct detector housing. Power Supervision Relay: Supervises the power to 4-wire NH-100: Fast-response, low-profile heat detector. smoke detectors and notification appliances. NH-100R: Fast-response, low-profile heat detector with rate- Wiring Requirements of-rise option. NH-100H: Fast-response, low-profile heat detector that acti While shielded wire is not required, it is recommended that all vales at 190°F/88°C. SLC wiring be twisted-pair to minimize the effects of electrical interference.Refer to the panel manual for wiring details. NP-A100:Addressable low-profile multi-sensor detector. DN-7102:E•02/22/2011—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic • Intelligent Signalling Line Circuits 1 components may be adversely affected by extreme tempera- • Addressable device capacity 50 ture ranges and humidity. Therefore, it is recommended that • Programmable software zones 20 this system and its peripherals be installed in an environment • Annunciators 8 with a normal room temperature of 15—27°C/60—80°F. Electrical Specifications NFPA Standards AC Power: FireWarden-50: 120 VAC, 60 Hz, 3.0 A. FireWar- The FireWarden-50 complies with the following NFPA 72 Fire den-50E:240 VAC,50 Hz, 1.5 A.Wire size:minimum 14 AWG Alarm Systems requirements: (2.00 mm2) with 600 V insulation. Nonpower-limited, super- —LOCAL (Automatic, Manual, Waterflow and Sprinkler vised. Supervisory). Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger —AUXILIARY(Automatic, Manual and Waterflow) (requires Capacity: 7-18 AH (FireWarden-50 cabinet holds maximum of 4XTM). two 18 AH batteries.) —REMOTE STATION (Automatic, Manual and Waterflow) Communication Loop: Supervised and power-limited. (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed Notification Appliance Circuits: Terminal Block provides transmitters. For reverse polarity signaling of alarm and connections for two NACs, Style Y(Class B)or Style Z(Class trouble,4XTM is required.) A). Special Application power. Power limited, supervised cir- —PROPRIETARY(Automatic,Manual and Waterflow). cuitry. Maximum signaling current per circuit: 2.5 A. End-of- Line Resistor:4.7k ohm,1/2 watt(P/N 71252 UL listed)for Style —CENTRAL STATION (Automatic, Manual and Waterflow, Y(Class B) NAC. Refer to the NOTIFIER Device Compatibility and Sprinkler Supervised). Document for listed compatible devices. —OT, PSDN (Other Technologies, Packet-switched Data Two Programmable Relays and One Fixed Trouble Relay: Network) Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays,nonpower-limited,nonsupervised. Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- Cabinet Specifications den-50 control panel. In some cases,certain modules may not Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x be listed by certain approval agencies,or listing may be in pro- 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x cess.Consult factory for latest listing status. 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring • UL:S635 (TR-CE/B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • FM approved Shipping Specifications • CSFM:7165-0028:239 • MEA:442-06-E Vol.2 Weight:26.9 lbs. (12.20 kg.)Dimensions:20.00"(50.80 cm.) NOTE:See DN-60446 for ULC-listed model. high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH NOTIFIER®, FireWarden®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-7102:E•02/22/2011 Honeywell =ire Alarm Communicators THE POWER OF CONNECTED IPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel(FACP)that has a built-in dialer.This single or dual path communicator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communicator Transmitter (DACT).It offers three selectable reporting paths which include:Cellular only,IP only, or IP primary/cellular backup.All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet®Network Control Center,which routes highly encrypted IPGSM-IG Commercial Fire Communicator Ethernet data packets via a customer provided internet connection or cellular network ■0.0101 to the appropriate central station.The state of the art AlarmNet network control center ■ ate is fully redundant and monitored 24/7.AlarmNet has the ability to route messages LfGtir using AlarmNet-I and 800 PLUS services,providing true redundancy and multi-path "onernv a message delivery. Alternative communication methods are critical in the marketplace due to VoIP(Voice over IP),migration from POTS(Plain Old Telephone Service)and growth of digital radio networks.The IPGSM-4G's single path communications solution allows one technology to be used(either IP or cellular)to provide the appropriate connectivity to a central station.For added reliability,our exclusive dual path solution allows both technologies(IP and cellular)to be used together for maximum survivability or for local jurisdiction requirements that specify a dual technology system. FEATURES & BENEFITS • Saves the cost of two • Operates over the • Works over any type of Private Static IP • QOS:Quality of Service dedicated phone lines. following customer provided addressing. diagnostics via communication Ethernet 10/100 based AlarmNet conveys vital • Single or dual path protocols:HSPA+(4G) network connection • Built-In Power Supply communicator communications-(can HSPA(HSDPA& (LAN or WAN),DSL module:On board information including communicate to HSUPA)(3G),EDGE modem or cable charging circuit design when message was central station using (2G GPRS)(2G). modem. accommodates back- received,signal cellular technology, up battery.Includes strength,and message internet,or both. • Selectable reporting • Data transmits over primary power and path used. paths and supervision standard contact-ID battery supervision. • Requires no change to intervals to meet NFPA protocol but is secured • 7720P Hand-held the existing Fire Alarm 72,chapter 26 with the industry's • Diagnostic LEDs: programmer for easy Control Panel requirements. advanced encryption Signal strength and setup. configuration. (Compliant with NFPA standard(AES 256 bit). status indicators. (Connects directly to 72 2010 and 2013 the primary and supervision • Supports both dynamic • Reliable connection:IP secondary telephone requirements.) (DHCP)or Public and and GSM connection ports of a DACT.) tested every day. The IPGSM-4G is designed to operate over the most • Primary City ID(two digits)obtained from your common cellular networks,including 3G and HSPA+. monitoring station. Its multi-GSM platform technology automatically • Primary CentralStation ID(two digits)obtained from chooses the best available cellular signal in the area your monitoring station. based on signal strength and seamlessly self-adjusts to maintain critical life safety communication.In • Primary Subscriber ID(four digits)obtained from addition,it connects to any type of customer provided your monitoring station. Ethernet 10/100 base network connection(LAN or • Communication Module's MAC ID,and MAC CRC WAN),DSL model or cable modem.Our selectable number located on outside of box,and inside of the reporting path feature allows the radio to be module. configured for a single or dual path solution as well as All of these parameters are assigned by the monitoring the appropriate supervision intervals based on NFPA station. 72 requirements.(See diagram below for selectable paths and supervision timing intervals.) Note:Some assembly is required.See Installation and Setup Guide #800-12454 for full details. Sekidaatefith Description Supervision Times Fire Communicator Capability 2010 GSM Single Path(cellular only) 5 minutes The IPGSM-4G is compatible with fire panels that use 2010 IP Single Path(IP only) 5 minutes the Contact ID communications format as described in 2010 IP&GSM Dual Path(IP and cellular) 24 hours the SIA DC 05 standard. 2013 GSM Single Path(cellular only) 1 hour AlarmNet 2013 IP Single Path(IP only) 1 hour Honeywell's AlarmNet has been the nationwide leader 20131P&GSM Dual Path(IP and cellular) 6 hours in alarm communications technology since 1986.A reliable alternative for the transmission of alarm Operation signals,our radio network provides extensive coverage When an event occurs,the Fire Alarm Control Panel in the United States and Canada.AlarmNet Network goes off hookto dialthe central station.The IPGSM-4G Control center processes signals from powerful servers Dialer Capture Module detects the off-hook condition in multiple locations equipped with 24/7 and provides the fire panel with a dial tone.When the infrastructure support.The AlarmNet network consist fire panel detects the dial tone,it begins dialing the of redundant hardware servers,hot back-up databases central station.After the dialing is completed,the and generators with battery back-up at all locations to Dialer Capture Module returns a handshake to the fire ensure continuity of service.Signals from Alarm-Net panel.The fire panel then sends the contact ID reports are transmitted to the central station's receivers using to the Dialer Capture Module,which in turn sends a multiple communications paths consisting of the kiss-off after the report is successfully received from Internet,radio network or toll-free POTS service. the fire panel.The Dialer Capture Module sends the contact ID reports to the IPGSM communications Installation Requirements module.When all the reports are sent,the fire panel UL COMPLIANCE goes on-hook.The IPGSM communications module To meet UL864/NFPA,ensure the following: then transmits the messages to the central station either over the GSM network or the Internet • IPGSM-4G must be installed in accordance with (dependent on configuration). NFPA(National Fire Protection Association) standards 70 and 72. Easy to Program The IPGSM 4G communicator can be pre- • IPGSM-4G must be mounted in the same room and programmed using the 7720P programmer to enter all within 20 feet of the fire panel. central-station information.This is saved to the • IPGSM-4G,and all equipment used for the IP IPGSM-4G communicator panel memory.When the connection(such as the router,hub,modem,etc.) IPGSM-4G communicator is installed at the site and shalt be listed,must be powered from an un- connected to the Internet/Intranet,it registers itself with the AlarmNet receiver. switched branch circuit,and be provided with appropriate standby power. For most installations,the only required parameters • IPGSM-4G must use the 7AH battery(not supplied) are: to provide 24-hour backup capability. 2 IPGSM-4G Technical Specifications ELECTRICAL PRODUCT LINE INFORMATION Ademco°and AlarmNet®are registered trademarks of Transformer: IPGSM-4G: Internet and Digital Cellular Fire Alarm Honeywell International Inc. Primary: 120VAC,60Hz,0.5A Communicator Panel.Includes red cabinet with Ademco® Secondary: 18VDC,50VA key and lock,wall outlet box,Dialer Capture Module,IGSM This document is not intended y Communications Module,antenna&mounting adapter, to be used for installation Battery: PowerBoostl power supply,LED display board, purposes.We try to keep our One 12 V 7.0 AH lead-acid battery:(not supplied) product information up-to- datey pp transformer,manual,&required screws,cables,etc. and accurate.We cannot Battery charging current: 1 Amp maximum Antenna External Hardware cover all specific applications Battery discharge current: Standby 230mA,Active GSM-ANT3DB: 3db gain external/remote antenna or anticipate all requirements. 950mA WA7626-CA: SNA to N Adapter All specifications are subjectto CABINET SPECIFICATIONS change without notice. 7626-50HC: 50 ft.antenna cable,low toss Dimensions: 14.875"H x 12.75"W x 3.0"D(37.8 cm H 7626-25HC: 25 ft.antenna cable,low loss x 32.4 cm W x 7.6 cm D) Note:The GSM-ANT3DB and the WA7626-CA are both required for Color: Red installing an external antenna along with the necessary cable needed (7626-50HC:50 ft.or 7626-25HC:25 ft.) SHIPPING SPECIFICATIONS Weight: 5.3 lbs.(6.94 kg) Other Accessories Dimensions: 15.625"H x 13.79"W x 9.25"D(39.7 cm H 7720P: PGSM-4G hand held programmer. x 34.9 cm W x 23.9 cm D) HPTCOVER: Plug-in transformer box for IPGSM communicator. TEMPERATURE AND HUMIDITY RANGES BAT-1270: Battery 12 Volts,7 AH,sealed. This system meets NFPA requirements for operation at 0- AGENCY LISTINGS AND APPROVALS 49°C/32-120°F and at a relative humidity 930/0±20/o RH (non condensing at 32°C±2°C(90°F±3°F).However,the The listings and approvals below apply to the basic useful life of the system's standby batteries and the IPGSM-4G communicator panel.In some cases,certain electronic components may be adversely affected by modules may not be listed by certain approval agencies, extreme temperature ranges and humidity.Therefore,it is or listing may be in process. recommended that this system and its peripherals be Consult factory for latest listing status. installed in an environment with a normal room UL Listed: S789 temperature of 15-27°C/60-80°F. CSFM:7300-1645:0199 FDNY:COA#6219 For more information Learn more about Honeywell's IPGSM-4G and other products available by visiting www.honeywellpower.com. Honeywell Power Products 12 Clintonville Road Northford,CT 06472-1610 877.HPP.POWR Honeywell DH-60769 I F 106/17 www.honeywell.com 02017 Honeywell International Inc. THE POWER OF CONNECTED DN-6995:D•Al-320 NP-1 00(A) Series NOTIFIER® Addressable Photoelectric Detectors by Honeywell Addressable Devices General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25)Addressable Fire Alarm Control Panels (' (FACPs).The NP-100T(A)adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly 0 MN locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional NP-1 00(A) in B210LP(A) Base accessory, PN RA100Z(A). The NP-100R(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detec- tor housings. OPTIONS Features • Remote LED output connection, PN RA100Z(A). SLC LOOP Applications • Two-wire loop connection. • Unit uses base for wiring. Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, especially where smol- ADDRESSING dering fires are anticipated. Ionization detectors are often better • Addressable by device. than photoelectric detectors at sensing fast,flaming fires. • Rotary, decimal addressing: 01 –99 with FireWarden-100-2 and NSP-25,P-2 and 01 –50 with FireWarden-50. Construction ARCHITECTURE These detectors are constructed of off-white fire resistant plas- tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A) series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple field base to simplify installation,service and maintenance. cleaning. Mount base(all base types)on an electrical backbox which is at OPERATION least 1.5" (3.81 cm) deep. For a chart of compatible junction • Withstands air velocities up to 4,000 feet-per-minute (20 m/ boxes,see DN 60054. sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring `T-taps" or • Factory preset at 1.5% nominal sensitivity for panel alarm branches are permitted for Style 4 (Class B) wiring. NP-100R(A) threshold level. mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed(communicat- ing with the fire panel)and latches on in alarm. Operation MECHANICALS Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25, or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports • Mounts to:single-gang box,3.5"(8.89 cm)or 4.0"(10.16 cm) its type and status. octagonal box,or 4.0"(10.16 cm)square electrical box(using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A) series has a unique unipolar chamber that responds quickly and uni- OTHER SYSTEM FEATURES formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient protec wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tion. sending an alarm level signal. Because of its unipolar chamber, the NP-100(A)series is approximately two times more respon- • 94-VO plastic flammability rating. sive than most photoelectric sensors.This makes it a more sta- • Low standby current. ble detector. DN-6995:D•2/11/2015—Page 1 of 2 Detector Sensitivity Test INTELLIGENT BASES Each detector can have its sensitivity tested(required per NFPA NOTE:"A"suffix indicates ULC Listed model. 72, Chapter 14 on Inspection, Testing and Maintenance) when NOTE:For details about intelligent bases and their mounting,see installed/connected to a FireWarden-100-2 or FireWarden-50 DN-60054. addressable fire alarm control panel.The results of the sensitiv- B210LP(A): Plug-in detector base (included); standard U.S. ity test can be printed off the FireWarden-100-2 or FireWarden- flanged low-profile mounting base. 50 for record keeping. B210LPBP:Bulk pack of B210LP;package contains 10. Specification B501(A):Standard European flangeless mounting base. Voltage range: 15—32 VDC(peak). B501 BP:Bulk pack of B501;package contains 10. Standby current:300 pA @ 24 VDC. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. LED current:6.5 mA @ 24 VDC(latched"ON"). Replaces B501 BH series bases in retrofit applications. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B224RB(A): Plug-in System Sensor relay base. Screw termi- Size:2.1"(5.33 cm)high;base determines diameter. nals:up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating:2.0 —B210LP(A):6.1"(15.5 cm)diameter. A @ 30 VDC resistive;0.3 A @ 110 VDC inductive; 1.0 A © 30 —B501(A):4.1"(10.4 cm)diameter. VDC inductive. —B200SR(A):6.875"(17.46 cm)diameter. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). —B224RB(A):6.2"(15.748 cm)diameter. Weight:3.6 oz.(102 g). ACCESSORIES Operating temperature range: for NP-100(A): 0°C to 49°C F110: Retrofit flange to convert B210LP(A) to match the (32°F to 120°F); for NP-100T(A):0°C to 38°C(32°F to 100°F). B710LP(A)profile,or to convert older high-profile bases to low- NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C (-4°F profile. to 158°F). F110BP: Bulk pack of F110;package contains 15. Temperature:0°C—49°C(32°F—120°F). F210: Replacement flange for B210LP(A)base. Relative humidity: 10%—93%,non-condensing. RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to a U.S. single-gang electrical box. For use with B501(A) and Listings B210LP(A)bases only. Listings and approvals below apply to the NP-100(A), NP- SMB600:Surface mounting kit 100T(A), and NP-100R(A) detectors. In some cases, certain M02-04-00:Test magnet. modules may not be listed by certain approval agencies,or list- MO2-09-00:Test magnet with telescoping handle. ing may be in process.Consult factory for latest listing status. UL Listed:S1115. XR2B: Detector removal tool.Allows installation and/or removal • of detector heads from bases in high ceiling applications. • ULC Listed:S1115. XP-4:Extension pole for XR2B.Comes in three 5-foot(1.524 m) • CSFM:7272-0028:0231. sections. • MEA:243-02-E Vol.2. T55-127-010:Detector removal tool without pole. • Maryland State Fire Marshal:permit 2173. BCK-200B: Black detector covers for use with NP-100(A) only; • FM approved. box of 10. WCK-200B:White detector covers for use with NP-100(A)only; Product Line Information box of 10. NOTE:A"suffix indicates ULC Listed model. NP-100: Addressable photoelectric detector; B210LP base included. NP-100A: Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B210LP base included. NP-100RA: Same as NP-100R with ULC Listing for use with a NOTIFIER® and FireWarden® are registered trademarks of Honeywell DNRA duct detector housing;B210LPA base included. International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. CERT 1 F E 11:10 We cannot cover all specific applications or anticipate all requirements. BICIPEBINC SMANNICHRIS All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6995:D•2/11/2015 DN-7001:D•Al-380 NOT-BG 12LX NOTIFIER® Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NOT-BG12LX is a state-of-the-art, dual-action F IRE (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG12LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. PUSH IN { 1 Features 1 PURI DOWN* • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. 6'' • Captive screw terminals wire-ready for easy connection to ONOT%F Eft SLC loop(accepts up to 12 AWG/3.25 mm2 wire). ` • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched,the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate mg the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight:9.6 oz.(272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 A. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, ing instructions provided on the cover. The word FIRE shall double-gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BG12LX is being semi flush mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounted, then the optional trim ring (BG12TR) may be used. mounting on a standard single gang, double gang, or 4"(10.16 cm) square electrical box, and shall be installed DN-7001:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-I/O:Surface backbox; plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. C E R T F E We cannot cover all specific applications or anticipate all requirements. immummmommums ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012 DN-6999:D Monitor Modules NOT' F 1 E Ft® NMM-100(A), NMM-100P(A), NZM-100(A), and NDM-100(A) for FireWarden Series by Honeywell aft Intelligent Addressable Devices General Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con tact input devices, such as conventional heat detectors and e pull stations, or monitor and power a circuit of two-wire smoke detectors(NZM-100(A)). NMM-100(A)is a standard-sized module(typically mounts to I °""" °- a 4"[10.16 cm]square box)that supervises either a Style D d (Class A) or Style B (Class B) circuit of dry-contact input a devices. NMM-100P(A) is a miniature monitor module a mere 1.3" "p (3.302 cm) H x 2.75" (6.985 cm)W x 0.5" (1.270 cm) D that , supervises a Style B (Class B) circuit of dry-contact input T *" t , devices. Its compact design allows the NMM-100P(A) to be • mounted in a single-gang box behind the device it monitors. \ � NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. NMM-100(A)(Type H) NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B to monitor normally-open supervisory devices with special (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol that greatly (provided) terminates the Style B circuit. No resistor is increases the speed of communication between analog intel- required for supervision of the Style D circuit. ligent devices. Intelligent devices communicate in a grouped NMM-100(A)OPERATION fashion. If one of the devices within the group has new infor- mation,the panel CPU stops the group poll and concentrates Each NMM-100(A) uses one of the available module on single points. The net effect is response speed greater addresses on an SLC loop. It responds to regular polls from than five times that of other communication protocols. the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing NMM-100(A) Monitor Module LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to • Built-in type identification automatically identifies this current limitations on the loop). device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional NMM-100(A)SPECIFICATIONS • power required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 350 pA(LED flashing), 1 corn- • Direct-dial entry of address: 01 —99 on FireWarden-100- munication every 5 seconds,47k EOL. 2,01 —50 on FireWarden-50. Maximum IDC wiring resistance: 1500 Ohms. • LED flashes during normal operation and latches on EOL resistance:47K Ohms. steady to indicate alarm. The NMM-100(A)Monitor Module is intended for use in intel- Temperature range:32°F to 120°F(0°C to 49°C). ligent, two-wire systems, where the individual address of Humidity range: 10%to 93%noncondensing. each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Device Circuit(IDC)for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices.The module has a panel-controlled LED 2.125"(5.398 cm)deep box. indicator. NMM-100P(A) Mini Monitor Module NMM-100(A)APPLICATIONS Use to monitor a zone of four wire smoke detectors, manual • Built-in type identification automatically identifies this device as a monitor module to the panel. fire alarm pull stations, waterflow devices, or other normally open dry-contact alarm activation devices. May also be used • Powered directly by two-wire SLC loop. No additional power required. DN-6999:D•01/20/2015—Page 1 of 4 • High noise(EMF/RFI)immunity. NZM-100(A) Interface Module • Tinned,stripped leads for ease of wiring. • Supports compatible two-wire smoke detectors. • Direct-dial entry of address: 01 —99 on FireWarden-100- • Supervises IDC wiring and connection of external power 2,01 —50 on FireWarden-50. source. • High noise(EMF/RFI)immunity. 3 1415 0 1 ADDRESS 0 1 • SEMS screws with clamping plates for ease of wiring. 3 12�1 3 043 7 • Direct-dial entry entry of address:,01 —99 on FireWarden- 11 �� 4 L� 100 2,01 —50 on FireWarden 50. 10 5 I I5 • LED flashes during normal operation. 9 8 s 9 8 7 6 • LED latches steady to indicate alarm on command from TENS ONES control panel. n n nn The NZM-100(A)Interface Module is intended for use in intel- ligent, addressable systems,where the individual address of each module is selected using built-in rotary switches. This O F._. O U module allows intelligent panels to interface and monitor two- - L Q wire conventional smoke detectors. It transmits the status Lu j m (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. I I I I NZM-100(A) APPLICATIONS The NMM-100P(A) Mini Monitor Module can be installed in a Use the NZM-100(A) to monitor a zone of two-wire smoke single-gang junction directly behind the monitored unit. Its Style Br( The B)mortored circuit may be wired as Devicen NFPA Cir- small size and light weight allow it to be installed without rigid Style 3.9 Kss B)End-of-Line Style D (ClassestA) p Initiating Ci s mounting. The NMM-100P(A) is intended for use in intelli- cult.A Ohm Resistor(provided)terminates gent,two-wire systems where the individual address of each theDloopoo of theiStylence is or D (class Install or circuit (maximum module is selected using rotary switches. It provides a two- IDC 9for Style application.2Ohms). ELR across termi- module initiating device circuit for normally-open-contact fire nals 8 and 9 for D alarm and security devices. NMM-100P(A) NZM-100(A)OPERATION NMM-100P(A)APPLICATIONS Each NZM-100(A) uses one of the available module Use to monitor a single device or a zone of four wire smoke addresses on an SLC loop. It responds to regular polls from detectors, manual fire alarm pull stations,waterflow devices, the controlnormal/short)pof and reportsgits type and the(ID status. A (open/ or other normally-open dry-contact devices. May also be EDindicates that its the mod lDeviceiCircuit nDC). n with used to monitor normally-open supervisory devices with spe- LED latches is in steadycoon alarm (subjects jthe cial supervisory indication at the control panel. Monitored cir- controlrrenpanel.t The LED the lloopes on alarm to cuit/device is wired as an NFPA Style B (Class B) Initiating current limitations on loop). Device Circuit. A 47K Ohm End-of-Line Resistor (provided) NZM-100(A)SPECIFICATIONS terminates the circuit. Nominal operating voltage: 15 to 32 VDC. NMM-100P(A)OPERATION Maximum current draw:5.1 mA(LED on). Each NMM-100P(A) uses one of the available module Maximum IDC wiring resistance:25 Ohms. addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ Average operating current: 300 pA, 1 communication and normal/short)of its Initiating Device Circuit(IDC). 1 LED flash every 5 seconds,3.9k eol. NMM-100P(A)SPECIFICATIONS - EOL resistance:3.9K Ohms. Nominal operating voltage: 15 to 32 VDC. External supply voltage(between Terminals T3 and T4): Average operating current:350 pA, 1 communication every DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC maximum.Current: 90 mA per module maximum. Shorted). Temperature range:32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Current:400 pA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. EOL resistance:47K Ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Dimensions: 1.3"(3.302 cm)high x 2.75"(6.985 cm)wide x 0.65" (1.651 cm)deep. Wire length:6"(15.24 cm)minimum. Page 2 of 4—DN-6999:D•01/20/2015 NDM-100(A) Dual Monitor Module • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- The NDM-100(A) Dual Monitor Module is intended for use in 100); 7300-0028:0237(NDM-100) intelligent, two-wire systems. It provides two independent two- • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); wire initiating device circuits(IDCs)at two separate,consecutive 227-03-E Vol.3(NDM-100) addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices.The module has a single panel- Product Line Information controlled LED. NOTE: The NDM-100(A)provides two Style B (Class B) IDC cir NOTE:` "suffix indicates ULC listed model. cuits ONLY Style D(Class A) /DC circuits are NOT supported in NMM-100(A): Monitor module. any application. NMM-100P(A): Monitor module, miniature. NDM-100(A)SPECIFICATIONS NZM-100(A): Monitor module,two-wire detectors. Normal operating voltage range: 15 to 32 VDC. NDM-100(A): Monitor module, dual, two independent Class Maximum current draw:6.4 mA(LED on). B circuits. Average operating current: 750 pA(LED flashing). SMB500:Optional surface-mount backbox. Maximum IDC wiring resistance: 1,500 Ohms. NOTE: See installation instructions and refer to the SLC Wiring Maximum IDC Voltage: 11 Volts. Manual, PN 52304. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm)deep. NDM-100(A)AUTOMATIC ADDRESSING The NDM-100(A)automatically assigns itself to two address- able points,starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A),NZM-100(A),and NDM-100(A)modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes,ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S635 • FM Approved DN-6999:D•01/20/2015—Page 3 of 4 Notifier®and FireWarden®are registered trademarks and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. IS O 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:D•01/20/2015 SYSTEM �$ SENSOR' Outdoor Selectable- Output Horns, - Strobes, and Horn Strobes for Wall Applications SPECTFwert SpectrAlert®Advance outdoor audible visible products/ .e► N c are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back.boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill -' holes for screw-in mounting.Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3A4-inch 7300-1653.187(outdoor strobes) LISTED MEA 7125-1653188(horn strobes, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket 54011(chimes,horn strobes,horns) APPROVED approvedchime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653.189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 10 110 Temporal 78 78 85 85 90 90 98 98 1115 115 6 Non- Low 135 135 Temporal 75 75 81 81 88 84 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. Avos01201 SpectrAlert Advance Diagrams 4.7" ►I 2.5" _ a \ -,.. ,,i,•740 \ ,...,. /--------- 5.6" r0 /I 1..„.___,H7 0/ ,......... 1 1. �" 1=.3 ---„42___ — I ■�.-' Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box .144-6.6..--..p.„-.------ '9 4 , Pte_ _ I v.,-",'". ..._ r. I o �II ®.j� .• r-, 1 • , IMI_.__ .----:_=.11 _-__:,-__:„ ......, " / 4 • "., __ `% _ ., J .. .GII ,_,-, .., Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd, Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd, Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White.Outdoor(includes plastic weatherproof back box) Horns HRKt Horn, Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. *� SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product speciflcat ons subject to change without notice.Visit systemsensor.com _)' SENSOR' Phone:800-S ENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01201•3/12