Loading...
Report . , - 0A51-20t:1- oc7 zptq IDIS,S 5t,..J Avv‘4,4 4,1( Project: Hazel_Lot 11 Armand Beams N page 3,Keith A Kudrna Location: Beam Nr. 01 -Garage Door Header �r #, Suntel Design Roof Beam , 16865 Boones Ferry Rd of [2015 International Residential Code(2015 NDS)] - ' "' -^- ,Lake Oswego,Oregon 97035 3.5 INx11.25INx16.5FT #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 10.0.1.5 7/26/2017 11:03:40 AM Section Adequate By:61.4% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM RECEIVED Live Load 0.15 IN L/1315 Dead Load 0.15 in Total Load 0.30 IN L/655 AUG 2 3 2017 Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 REACTIONS A B CITY OF TIGARO Live Load 495 lb 495 lb BUILDING DIVISION Dead Load 499 lb 499 lb Total Load 994 lb 994 lb Bearing Length 0.45 in 0.45 in REAM DATA Span Length 16.5 ft Unbraced Length-Top 0 ft 16.5 ft Unbraced Length-Bottom 0 ft Roof Pitch 10 :12 Roof Duration Factor 1.15 ROOF LOADING MATERIAL PROPERTIES Side One: #2-Douglas-Fir-Larch(North) Roof Live Load: LL= 30 psf Base Values Adjusted Roof Dead Load: DL= 20 psf Bending Stress: Fb= 850 psi Fb'= 1075 psi Tributary Width: TW= 1 ft Cd=1.15 CF=1.10 Side Two: Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Live Load: LL= 30 psf Cd=1.15 Roof Dead Load: DL= 20 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Tributary Width: TW= 1 ft Comp.L to Grain: Fc--L= 625 psi Fc-1'= 625 psi Wall Load: WALL= 0 plf Controlling Moment: 4098 ft-lb 8.25 ft from left support SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Created by combining all dead and live loads. Adjusted Beam Length: Ladj= 16.5 ft Controlling Shear: -894 lb Beam Self Weight: BSW= 8 plf At a distance d from support. Beam Uniform Live Load: wL= 60 plf Created by combining all dead and live loads. Beam Uniform Dead Load: wD_adj= 60 plf Total Uniform Load: wT= 120 plf Comparisons with required sections: Req'd Provided Section Modulus: 45.74 in3 73.83 in3 Area(Shear): 6.48 in2 39.38 in2 Moment of Inertia(deflection): 114.1 in4 415.28 in4 Moment: 4098 ft-lb 6615 ft-lb Shear: -894 lb 5434 lb NOTES Project: Hazel_Lot 11 Annand Beams , Lr_ page Kei• th A Kudrna / Location: Beam Nr.02-Roof Beam at Entry flit Suntel Design Roof Beam $ 16865 Boones Ferry Rd of [2015 International Residential Code(2015 NDS)] : Lake Oswego,Oregon 97035 3.5 IN x 7.25 IN x 5.0 FT #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 10.0.1.5 7/26/2017 11:03:40 AM Section Adequate By: 181.1% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.02 IN L/3892 Dead Load 0.01 in Total Load 0.03 IN L/2053 Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 REACTIONS A_ Live Load 488 lb 488 lb Dead Load 437 lb 437 lb Total Load 925 lb 925 lb Bearing Length 0.42 in 0.42 in BEAM DATA Span Length 5 ft Unbraced Length-Top 0 ft 5 ft Unbraced Length-Bottom 0 ft Roof Pitch 10 :12 Roof Duration Factor 1.15 ROOF LOADING MATERIAL PROPERTIES Side One: #2-Douglas-Fir-Larch(North) Roof Live Load: LL= 30 psf Base Values Adjusted Roof Dead Load: DL= 20 psf Bending Stress: Fb= 850 psi Fb'= 1271 psi Tributary Width: TW= 1.5 ft Cd=1.15 CF=1.30 Side Two: Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Live Load: LL= 30 psf Cd=1.15 Roof Dead Load: DL= 20 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Tributary Width: TW= 5 ft Comp. L to Grain: Fc- = 625 psi Fc- = 625 psi Wall Load: WALL= 0 plf Controlling Moment: 1155 ft-lb SLOPE/PITCH ADJUSTED LENGTHS AND LOADS 2.5 ft from left support Adjusted Beam Length: Ladj= 5 ft Created by combining all dead and live loads. Beam Self Weight: BSW= 5 plf Controlling Shear: -702 lb Beam Uniform Live Load: wL= 195 plf At a distanced from support. Beam Uniform Dead Load: wD_adj= 175 plf Created by combining all dead and live loads. Total Uniform Load: wT= 370 plf Comparisons with required sections: Read Provided Section Modulus: 10.91 in3 30.66 in3 Area(Shear): 5.09 in2 25.38 in2 Moment of Inertia(deflection): 9.74 in4 111.15 in4 Moment: 1155 ft-lb 3247 ft-lb Shear: -702 lb 3502 lb NOTES page Project: Hazel_Lot 11 Armand Beams " ,1 Keith A Kudrna Location: Beam Nr.03-Silder ar Great Room Header Suntel Design / Roof Beam 16865 Boones Ferry Rd of [2015 International Residential Code(2015 NDS)] Lake Oswego,Oregon 97035 5.5 IN x 11.25 IN x 6.5 FT #1 -Douglas-Fir-Larch(North)-Dry Use StruCalc Version 10.0.1.5 7/26/2017 11:03:40 AM Section Adequate By: 111.2% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.03 IN U2759 Dead Load 0.02 in Total Load 0.05 IN L/1565 Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: U180 REACTIONS A Live Load 2389 lb 2389 lb Dead Load 1823 lb 1823 lb Total Load 4212 lb 4212 lb Bearing Length 1.23 in 1.23 in BEAM DATA Span Length 6.5 ft •' u Unbraced Length-Top 0 ft 6.5 ft Unbraced Length-Bottom 0 ft Roof Pitch 6 :12 Roof Duration Factor 1.15 ROOF LOADING MATERIAL PROPERTIES Side One: #1 -Douglas-Fir-Larch(North) Roof Live Load: LL= 30 psf Base Values Adjusted Roof Dead Load: DL= 20 psf Bending Stress: Fb= 1300 psi Fb'= 1495 psi Tributary Width: TW= 1.5 ft Cd=1.15 CF=1.00 Side Two: Shear Stress: Fv= 170 psi Fv'= 196 psi Roof Live Load: LL= 30 psf Cd=1.15 Roof Dead Load: DL= 20 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Tributary Width: TW= 23 ft Comp.-L to Grain: Fc- = 625 psi Fc-1'= 625 psi Wall Load: WALL= 0 plf Controlling Moment: 6844 ft Ib SLOPE/PITCH ADJUSTED LENGTHS AND LOADS 3.25 ft from left support Adjusted Beam Length: Ladj= 6.5 ft Created by combining all dead and live loads. Beam Self Weight: BSW= 13 plf Controlling Shear: 3033 lb Beam Uniform Live Load: wL= 735If At a distance d from support. p Created by combining all dead and live loads. Beam Uniform Dead Load: wD_adj= 561 plf Total Uniform Load: wT= 1296 plf Comparisons with required sections: Recp'd Provided Section Modulus: 54.94 in3 116.02 in3 Area(Shear): 23.27 in2 61.88 in2 Moment of Inertia(deflection): 75.06 in4 652.59 in4 Moment: 6844 ft-lb 14454 ft-lb Shear: 3033 lb 8064 lb NOTES page Project: Hazel_Lot 11 Armand BeamsKeith A Kudrna / Location: Beam Nr.04-Rear Deck Beam — Suntel Design Uniformly Loaded Floor Beam 16865 Boones Ferry Rd of [2015 International Residential Code(2015 NDS)] Lake Oswego, Oregon 97035 3.5 IN x 9.25 IN x 8.5 FT #2-Douglas-Fir-Larch(North)-Dry Use StruCalc Version 10.0.1.5 7/26/2017 11:03:41 AM Section Adequate By: 14.7% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.11 IN L/930 Dead Load 0.02 in Total Load 0.13 IN L/784 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 1466 lb 1466 lb Dead Load 274 lb 274 lb Total Load 1740 lb 1740 lb Bearing Length 0.80 in 0.80 in BEAM DATA Centerm�. .u� .u: .�u ,. ...... .. _ G,,...; , Span Length 8.5 ft Unbraced Length-Top 0 ft 8.5 ft Floor Duration Factor 1.00 Notch Depth 0.00 MATERIAL PROPERTIES FLOOR LOADING #2-Douglas-Fir-Larch(North) Side 1 Side 2 Base Values Adjusted Floor Live Load FLL= 60 psf 0 psf Bending Stress: Fb= 850 psi Fb'= 1020 psi Floor Dead Load FDL= 10 psf 0 psf Cd=1.00 CF=1.20 Floor Tributary Width FTW= 5.8 ft 0 ft Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Wall Load WALL= 0 plf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING Comp.-L to Grain: Fc- L= 625 psi Fc--- = 625 psi Beam Total Live Load: wL= 345 plf Beam Total Dead Load: wD= 58 plf Controlling Moment: 3697 ft-lb Beam Self Weight: BSW= 7 plf 4.25 ft from left support Total Maximum Load: wT= 409 plf Created by combining all dead and live loads. Controlling Shear: -1427 lb At a distance d from support. Created by combining all dead and live loads. Comparisons with required sections: Rea'd Provided Section Modulus: 43.5 in3 49.91 in3 Area(Shear): 11.89 in2 32.38 in2 Moment of Inertia(deflection): 89.37 in4 230.84 in4 Moment: 3697 ft-lb 4242 ft-lb Shear: -1427 lb 3885 lb NO E