Loading...
Report (99) ezte,017-(-2..) 521 \-4-cc‘ S\ :) Uc \-Nr\ PBS Engineering + Environmental RE( V)4 SEP 1 4 2017 cm'OF'TGAR, I BUILDING DIVISWt; Geotechnical Engineering Report Proposed Hotel Development SW 69th Avenue and SW Clinton Street Tigard, Oregon I I Prepared for: DAVCKOR LLC Attn: Alkesh Patel 1419 West Main Street #100 Battle Ground, WA 98604 I February 4,2016 Project No. 70976 000 I 15000 Street,Vancouvw,WA 98663 360 690 4331 Main 866 727,0140 Fax www.pbsenv.com Bend I Boise I Coos Bay I Eugene I Portland I Seattle I TO-Cities I Vancouver 1 , I PBS pEngineering + Environmental I February 4, 2016 IGeotechnical Engineering Report Proposed Hotel Development I SW 69th Avenue and SW Clinton Street Tigard, Oregon IProject No. 70976.000 I Prepared for: DAVCKOR LLC Attn: Mr. Alkesh Patel I 1419 West Main Street, #100 Battle Ground, WA 98604 IPrepared by: I PFR ,r 6 � 1 '' ,} IE'sii,N vs IONY EXPIRES. 12/31/2016 ITony Rikli, PE Geotechnical Staff Engineer IReviewed by: yan White, PE, GE IGeotechnical Discipline Lead This document was prepared for use only by the Client,only for the purposes stated,and within a reasonable time from issuance, II but in no event later than three years from the date of the report.Non-commercial,educational,and scientific use of this report by regulatory agencies is regarded as a"fair use"and not a violation of copyright. Regulatory agencies may make additional copies of this document for internal use.Copies may also be made available to the public as required by law.The reprint must acknowledge the copyright and indicate that permission to reprint has been received. I I Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon ITABLE OF CONTENTS 1.0 INTRODUCTION 1 I 1.1 General 1 1.2 Purpose and Scope 1 1.2.1 Literature and Records Review 1 I 1.2.2 Subsurface Explorations 1 1.2.3 Soils Testing 1 1.2.4 Geotechnical Engineering Analysis 1 1.2.5 Report Preparation 1 1.3 Project Understanding 2 2.0 SITE CONDITIONS 2 2.1 Surface Description 2 i2.2 Geologic Setting 3 2.2.1 Regional Geology 3 2.2.2 Local Geology 3 I 2.3 Subsurface Conditions 3 2.3.1 Soil 3 2.3.2 Groundwater 3 2.3.3 Infiltration Testing 4 3.0 CONCLUSIONS AND RECOMMENDATIONS 4 3.1 Geotechnical Design Considerations 4 II 3.2 Shallow Foundations 4 3.2.1 Footing Preparation 4 3.2.1 Spread Footings and Stem Walls 4 3.2.2 Footing Embedment Depths 5 I3.2.3 Minimum Footing Widths / Design 5 3.2.4 Crushed Rock Pads 5 3.2.5 Foundation Static Settlement 5 I 3.2.6 Lateral Resistance 5 3.3 Seismic Design Criteria 5 3.3.1 Liquefaction Potential 6 I 3.3.2 Other Seismic Considerations 6 3.4 Floor Slabs 6 3.5 Ground Moisture 7 I 3.5.1 General 7 3.5.2 Perimeter Footing Drains 7 3.6 Pavement Design Analyses 7 I 4.0 CONSTRUCTION RECOMMENDATIONS 8 4.1 Site Preparation 8 4.1.1 Proofrolling/Subgrade Verification 8 I 4.2 Subgrade Protection 8 4.2.1 Wet-Weather/Wet-Soil Conditions 8 4.2.2 Dry Weather Conditions 9 4.3 Excavation 9 11, 4.4 Slopes 9 4.5 Structural Fill 9 4.5.1 On-Site Soil 9 I 4.5.2 Borrow Material 10 4.5.3 Select Granular Fill 10 4.5.4 Crushed Aggregate Base 10 I4.5.5 Utility Trench Backfill 10 February 4,2016 Engineering+ Project No.70976.000 IP B S Environmental 1 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon 4.5.6 Stabilization Material 11 1 5.0 ADDITIONAL SERVICES AND CONSTRUCTION OBSERVATIONS 11 6.0 LIMITATIONS 11 7.0 REFERENCES 13 SUPPORTING DATA Figures Figure 1 Vicinity Map Figure 2 Site Plan Appendix A— Field Explorations Table A-1 Terminology Used to Describe Soil Table A-2 Key to Test Pit and Boring Log Symbols Figures Al —A6 Logs for Borings B-1 through B-6 I Appendix B— Laboratory Testing Figure B1 Atterberg Limits Test Results I Figure B2 Consolidation Test Results I I I 1 I 1 I 1 I I February 4,2016 Engineering} Project No.70976.000 p B Environmental ii I Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon I1.0 INTRODUCTION 1.1 General I This report presents the results of the PBS Engineering and Environmental Inc. (PBS) geotechnical engineering services for the proposed hotel development in Tigard, Oregon. The site location is shown on the Vicinity Map, Figure 1. The exploration locations in relation to Iexisting and proposed site features are shown on the Site Plan, Figure 2. 1.2 Purpose and Scope I The purpose of PBS' services was to develop geotechnical design and construction recommendations in support of the proposed new structure. This was accomplished by performing the following scope of services: i1.2.1 Literature and Records Review PBS reviewed various relevant published geologic maps of the area for information I regarding geologic conditions. We also reviewed previously completed reports near the site that were available in our files. 1.2.2 Subsurface Explorations 1 PBS completed six borings within the proposed development area. Borings B-1 and B-2 were advanced to depths 6.5 below the existing ground surface (bgs) in the proposed parking area and borings B-3 through B-6 were completed to depths of up to 36.5 feet bgs I within the proposed building footprint. Borings were logged and representative soil samples collected by a member of the PBS engineering staff. Infiltration testing was conducted at a depth of approximately 5.0 feet bgs in borings B-1 and B-2. 1 1.2.3 Soils Testing Collected soil samples were transported to our laboratory for testing that included natural I moisture contents, Atterberg Limits testing, and consolidation testing (refer, Appendix B - Laboratory Testing). I 1.2.4 Geotechnical Engineering Analysis Data collected during the subsurface explorations, literature research, and laboratory testing was used to develop specific geotechnical design and construction recommendations. I1.2.5 Report Preparation This Geotechnical Engineering Report summarizes the results of our explorations, testing, and analyses, including information relating to the following: I • Field exploration logs and approximate exploration locations • Infiltration test results 1 • Laboratory test results I . Earthwork and grading, cut, and fill recommendations: - Evaluation of the site soils for use as fill - Temporary and permanent slope inclinations for utilities - Structural fill materials and preparation - Wet and cold weather considerations I February 4,2016 Engineering+ Project No.70976.000 IPBS Environmental 1 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon • Shallow foundation design recommendations: 111 - Minimum embedment - Allowable bearing pressure - Estimated settlement - Sliding coefficient • Groundwater levels and considerations • Subsurface drainage requirements I • Seismic design criteria in accordance with the current (2014) Oregon Structural Specialty Code (OSSC) • Slab and pavement subgrade preparation • Recommended pavement section thickness 111 1.3k Project Understanding PBS understands that preliminary plans include development of approximately 1.9 acres of land consisting of several parcels (#1S136DD02400, #1S136DD02300, #1S136DD02200, #1S136DD02100, 1S136DD02500) near SW 69th Avenue and SW Clinton Street (site, subject property) in Tigard, Oregon. The site is currently undeveloped and vegetated with mature trees and brush. The property slopes down to the west, with elevations ranging from 277 to 297 feet above mean sea level (AMSL). PBS understands that the project will consist of constructing one approximately 23,000 square foot (footprint) four-story wood frame hotel building, with slab-on-grade floors and conventional shallow foundations. The remainder of the site will consist of associated asphalt concrete (AC) pavement parking, driveways, and landscaping. Based on our experience with similar projects, estimated maximum building loads will be on the order of 350 kips for columns, 5 kips per linear foot for walls, and less than 150 pounds per square foot (psf)for floors. The extent of site grading is currently unknown; however based on our understanding of the proposed development and existing topography, cuts and fills could be on the order of 5 feet. The purpose of PBS' services was to evaluate the subsurface conditions within the site and provide geotechnical information needed to develop recommendations for use in design and construction. 2.0 SITE CONDITIONS I 2.1 Surface Description The subject property is located on the northeastern side of the City of Tigard, bounded by SW 70th Avenue to the west, SW Clinton Street on the south, SW 69th Avenue to the east, and residential development to the north. The 1.9-acre site is lightly vegetated, slopes down to the west, and lies approximately 0.2 mile south of an unnamed small tributary drainage and 0.4 mile northeast of Crystal Lake in Tigard. Existing concrete foundations and slabs with sporadic concrete chunks and red brick were observed in the southeastern quadrant of the development area, possibly due to the previous structure that was demolished around July 2005. February 4,2016 PBSEngineering+ Project No.70976.000 PBS Environmental 2 i Geotechnical Engineering Report Proposed Hotel Development Tigard, Oregon 2.2 Geologic Setting 2.2.1 Regional Geology Schlicker and Deacon (1967) map the site geology as Quaternary Willamette Silt. Quaternary Willamette Silt is characterized as bedded silt and fine sand with occasional clay, lenses of pebbly, fine- to medium-grained sand, with locally scattered granite and quartzite cobbles. The unit is approximately 50 feet thick near the center of the Tualatin Valley and thins toward the valley margins. 2.2.2 Local Geology Locally, the site is mapped as Quaternary fine-grained boring lavas (QTb) according to Beeson, et. al. (1989). The QTb was deposited through a series of local vents from Mt. Sylvania. Concerning our borings, the clay and silt deposits encountered at the site are consistent with QTb. 2.3 Subsurface Conditions 1 2.3.1 Soil Subsurface conditions at the site were explored by drilling six borings designated as B-1 through B-6. The borings were advanced to depths of up to 36.5 feet bgs and completed on November 23 and 24, 2015. Borings were drilled by Western States Soil Conservation, Inc., of Hubbard, Oregon, using hollow-stem auger drilling techniques ( B-1 and B-2) and mud rotary drilling techniques on (B-3 through B-6). Infiltration testing was conducted at a depth of 5 feet bgs in borings B-1 and B-2. The explorations were logged and representative samples collected by a member of the PBS geotechnical engineering staff. Boring logs summarizing the subsurface conditions encountered in the explorations are presented in Appendix A. PBS has summarized the subsurface units as follows: SURFACE Topsoil approximately 6 inches thick was observed at the surface of MATERIALS: the borings. FILL: Borings B-5 and B-6 encountered fill material consisting of medium stiff to hard CLAY/SILT (CL/ML) to very dense clayey GRAVEL (GC) and poorly graded GRAVEL (GP) to 14 and 10.5 feet bgs, respectively. CLAY/SILT Medium stiff to hard brown CLAY/SILT (CL/ML)was encountered in the borings to the termination depths of 36.5 feet bgs. The soil types are based on visual-manual classifications using ASTM D 2488-09a guidelines. Consistency, color, relative moisture, degree of plasticity, and other distinguishing characteristics of the soil layers were noted. The terminology used in the soil classifications and other modifiers are defined and presented on the attached Table A-1 included in Appendix A. 2.3.2 Groundwater Static groundwater was not observed at the time of our explorations. Nearby well logs and regional groundwater mapping by the United States Geological Survey (USGS) indicate groundwater present at depths of approximately 20 feet bgs or deeper. Shallow zones of perched water may be present seasonally. We recommend that the contractor determine the February 4,2016 Engineering+ Project No.70976.000 p B Environmental 3 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon actual groundwater levels at the time of construction to determine potential groundwater impact on the construction. 2.3.3 Infiltration Testing I PBS completed infiltration testing in B-1 and B-2 at depths of approximately 5.0 feet bgs through a hollow-stem auger. The tests were completed in general accordance with the City of Portland 2014 Stormwater Management Manual. The auger was advanced to the test depths and was filled with water to saturate the soil. Following saturation, the water was allowed to drain while the water level was recorded at regular time intervals. No measurable infiltration was observed over the 4-hour test period. 3.0 CONCLUSIONS AND RECOMMENDATIONS 3.1 Geotechnical Design Considerations , The majority of the project site is underlain by medium stiff to hard clay soils to depths of approximately 36.5 feet bgs. Undocumented fill was also encountered in B-5 and B-6 to a depth of 14 and 10.5 feet bgs, respectively. Conventional foundation support on shallow footings (spread) is feasible. Because the fill encountered at the site is undocumented, we recommend additional measures be implemented into the project design to help reduce the impacts of its presence. These should include installation of 1-foot-thick crushed rock pads beneath the footings and designing stem walls to free-span a distance of 5 feet. Alternatively, walls could be supported on grade beams designed to span between column footings. Specific recommendations are provided in the following sections. Without complete removal of the undocumented fill and replacement with structural fill, a risk of settlement still exists. The grading and final development plans for the project had not been completed when this report was prepared. Subsequently, we have not evaluated the impacts of site grading on the static and seismic stability of the existing slopes, and have estimated settlement of the underlying soils based on the estimated loads using our engineering judgment. Once completed, PBS should be engaged to review the project plans and update our recommendations as necessary. 3.2 Shallow Foundations The following sections provide a more detailed discussion of our analysis and I recommendations. 3.2.1 Footing Preparation Excavations for footings should be carefully prepared to a neat and undisturbed state on firm native soil. A representative from PBS should confirm suitable bearing conditions and evaluate all exposed footing subgrades. Observations should also confirm that loose or soft materials have been removed from new footing excavations and concrete slab-on-grade areas. Localized deepening of footing excavations may be required to penetrate loose, wet, or deleterious materials. i 3.2.1 Spread Footings and Stem Walls Due to the presence of undocumented fill, we recommend that continuous footings and/or stem walls be structurally designed to free span a distance of 5 feet. Given the variability of the fill, strengthening the footings and stem walls should prevent excessive foundation differential settlement. February 4,2016 Engineering+ Project No.70976.000 P B S Environmental 4 1 PBS Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon I 3.2.2 Footing Embedment Depths I We recommend that all footings be founded a minimum of 18 inches below the lowest adjacent grade. The footings should be founded below an imaginary line projecting upward at a 1 H:1 V (horizontal to vertical) slope from the base of any adjacent, parallel utility Itrenches or deeper excavations. 3.2.3 Minimum Footing Widths / Design I Continuous wall and isolated spread footings should be at least 24 inches wide. Footings should be sized using a maximum allowable bearing pressure of 2,500 pounds per square foot (psf). This is a net bearing pressure and the weight of the footing and overlying backfill can be disregarded in calculating footing sizes. The recommended allowable bearing I pressure applies to the total of dead plus long-term-live loads. Allowable bearing pressures may be increased by one-third for seismic and wind loads. I The building foundations must be installed on a minimum of one-foot-thick crushed rock pads, as discussed in the following Section 3.2.4 of this report. I 3.2.4 Crushed Rock Pads Due to the presence of undocumented fill, we recommend footings be founded on one-foot-thick crushed rock pads. Crushed rock pads should be planned to extend a I minimum of six inches laterally beyond the edges of footings. For an 18-inch-wide footing, the crushed rock pad should be 3.5 feet wide. Following excavation, prior to installing crushed rock pads, footing subgrades should be compacted with multiple, overlapping Ipasses of a vibratory compactor. Crushed rock pads should be prepared following the recommendations specified in Section 4.5.4—Crushed Aggregate Base of this report. I 3.2.5 Foundation Static Settlement Footings will settle in response to column and wall loads. Based on our evaluation of the I subsurface conditions and our analysis, we estimate post-construction settlement will be less than one inch for the column and perimeter foundation loads.. Differential settlement will be on the order of one-half of the total settlement. I3.2.6 Lateral Resistance Lateral loads can be resisted by passive earth pressure on the sides of footings and grade I beams, and by friction at the base of the footings. A passive earth pressure of 250 pounds per cubic foot (pcf) may be used for footings confined by native soils and new structural fills. The allowable passive pressure has been reduced by one-half to account for the large I amount of deformation required to mobilize full passive resistance. Adjacent floor slabs, pavements, or the upper 12-inch depth of adjacent unpaved areas should not be considered when calculating passive resistance. For footings supported on native soils or new structural I fills, use a coefficient of friction equal to 0.35 when calculating resistance to sliding. These values do not include a factor of safety (FS). 3.3 Seismic Design Criteria IThe seismic design parameters, in accordance with the 2014 Oregon Structural Specialty Code (OSSC), are summarized in Table 1 as follows: I February 4,2016 Engineering+ Project No.70976.000 I P BS Environmental 5 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon Table 1: 2014 OSSC Seismic Design Parameters Parameter Short Period 1 Second Maximum Credible Earthquake Spectral I Acceleration SS = 0.98 g S1 = 0.42 g Site Class D Site Coefficient Fa = 1.11 Fv = 1.58 Adjusted Spectral Acceleration SMS = 1.09 g SM1 = 0.67 g Design Spectral Response Acceleration I Parameters Sps = 0.73 g Soo = 0.45 g Design Spectral Peak Ground Acceleration 0.29 g g—Acceleration due to gravity 3.3.1 Liquefaction Potential Liquefaction is defined as a decrease in the shear resistance of loose, saturated, cohesionless soil (e.g., sand) or low plasticity silt soils, due to the buildup of excess pore pressures generated during an earthquake. This results in a temporary transformation of the soil deposit into a viscous fluid. Liquefaction can result in ground settlement, foundation I bearing capacity failure, and lateral spreading of ground. Based on a review of the Oregon Statewide Geohazard Viewer (HazVu), the property is located in an area of low liquefaction hazard. We did not encounter potentially liquefiable soils in our explorations. As a result, our current opinion is that the risk of structurally damaging liquefaction settlement at the site is low. 3.3.2 Other Seismic Considerations Other site-specific seismic hazards considered include earthquake-induced landslides, ground shaking, fault rupture, seiche and tsunami inundation, lateral spreading, and earthquake shaking. Based on the topography, geology, and closest freeface to the site, we consider the risk from earthquake-induced lateral spreading, seiche and flood inundation to be low. Strong earthquake ground shaking will occur during a design-level seismic event on the Cascadia Subduction Zone (CSZ). The site lies between the Canby-Molalla Fault and the Oatfield Fault, which, according to DOGAMI HazVu, may also induce strong shaking at the site. Based on our current understanding of the project, our opinion is that effects of earthquake ground motions can be accounted for by using code-based design procedures. 3.4 Floor Slabs Satisfactory subgrade support for building floor slabs can be obtained from the near-surface clay subgrade prepared in accordance with our recommendations presented in the Site Preparation, Wet Weather/Wet-Soil Conditions and Crushed Aggregate Base sections of this report. A minimum six-inch-thick layer of imported granular material should be placed and compacted over the prepared subgrade. Imported granular material should be composed of crushed rock or crushed gravel that is relatively well graded between coarse and fine, contains no deleterious materials, has a maximum particle size of one inch, and has less than five percent by dry weight passing the US Standard No. 200 Sieve. Floor slabs supported on a subgrade and base course prepared in accordance with the 1 preceding recommendations may be designed using a modulus of subgrade reaction (k) of 150 pounds per cubic inch (pci). February 4,2016 Engineering+ Project No.70976.000 PBSEnvironmental 6 1 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon I 3.5 Ground Moisture 3.5.1 General The perimeter ground surface and hard-scape should be sloped to drain away from all structures and away from adjacent slopes. Gutters should be tight-lined to a suitable discharge and maintained as free-flowing. All crawl spaces should be adequately ventilated and sloped to drain to a suitable, exterior discharge. 3.5.2 Perimeter Footing Drains Due to the relatively low permeability of the near-surface site soils and the potential for perched groundwater at the site, we recommend perimeter foundation drains be installed around all proposed structures. The foundation subdrainage system should include a minimum 4-inch-diameter perforated pipe in a drain rock envelope. A non-woven geotextile filter fabric, such as Mirafi 140N or equivalent, should be used to completely wrap the drain rock envelope, separating it from the native soil and footing backfill materials. The invert of the perimeter drain lines should be placed approximately at the bottom of footing elevation. Also, the subdrainage system should be sealed at the ground surface. The perforated subdrainage pipe should be laid to drain by gravity into a non-perforated solid pipe and finally connected to the site drainage stem at a suitable location. Water from downspouts and surface water should be independently collected and routed to a storm sewer or other positive outlet. This water must not be allowed to enter the bearing soils. 3.6 Pavement Design Analyses The provided pavement recommendations were developed using the American Association of State Highway and Transportation Officials (AASHTO) design methods and references the associated Oregon Department of Transportation (ODOT) specifications for construction. Our evaluation considered a maximum of two trucks per day for a 20-year design life. The minimum recommended pavement sections are provided in Table 2. Table 2: Minimum AC Pavement Sections AC Base Rock Traffic Loading Subgrade (inches) (inches) Pull-in Car Parking Only 2.5 g Stiff subgrade as verified by PBS Drive Lanes and Access Roads 3.0 9 personnel The asphalt cement binder should be PG 70-22 Performance Grade Asphalt Cement according to ODOT SS 00744.11 —Asphalt Cement and Additives. The AC should consist of'A-inch hot mix asphalt concrete (HMAC) and the maximum lift thickness should not exceed 3 inches. The AC should conform to ODOT SS 00744.13 and 00744.14 and be compacted to 91 percent of maximum theoretical density (Rice value) of the mix, as determined in accordance with ASTM D2041. Heavy construction traffic on new pavements or partial pavement sections (such as base course over the prepared subgrade)will likely exceed the design loads and could potentially damage or shorten the pavement life. Therefore, we recommend construction traffic not be allowed on new February 4,2016 Engineering+ Project No.70976.000 PBSEnvironmental 7 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon pavements, or that the contractor take appropriate precautions to protect the subgrade and pavement during construction. If construction traffic is to be allowed on newly constructed road sections, an allowance for this additional traffic will need to be made in the design pavement section. 4.0 CONSTRUCTION RECOMMENDATIONS I 4.1 Site Preparation Construction of the proposed building will involve clearing and grubbing of the existing vegetation and/or demolition of existing pavements. Demolition should include removal of existing foundations, utilities, etc., throughout the proposed new building footprint. Underground utility lines, or other abandoned structural elements should also be removed. The voids resulting from removal of foundations or loose soil in utility lines should be backfilled with compacted structural fill. The base of these excavations should be excavated to firm native subgrade before filling, with sides sloped at a minimum of 1 H:1V, to allow for uniform compaction. Materials generated during demolition should be transported off site or stockpiled in areas 111 designated by the owner's representative. 4.1.1 Proofrolling/Subgrade Verification Following site preparation and prior to placing aggregate base for the shallow foundations, building pad, or pavement sections, the exposed subgrade should be evaluated either by proofrolling or another method of subgrade verification. The subgrade should be proofrolled with a fully loaded dump truck or similar heavy, rubber-tire construction equipment to identify unsuitable areas. If evaluation of the subgrades occur during wet conditions, or if proofrolling the subgrades will result in disturbance, they should be evaluated by PBS using a steel foundation probe. We recommend that PBS be retained to observe the proofrolling and perform the subgrade verifications. Unsuitable areas identified during the field evaluation should be compacted to a firm condition or be excavated and replaced with structural fill. 4.2 Subgrade Protection 4.2.1 Wet-Weather/Wet-Soil Conditions I Due to the presence of fine-grained soil (i.e. silt and clay) in the near-surface materials within the construction area, construction equipment may have difficulty operating on the near-surface soils when above the optimum moisture required for compaction. Soils that I have been disturbed during site preparation activities, or unsuitable areas identified during proofrolling or probing, should be removed to firm ground and replaced with compacted structural fill. I Protection of the subgrade is the responsibility of the contractor. Track-mounted excavating equipment may be required during wet weather. The thickness of the haul roads to access the site for basement excavation and staging areas will depend on the amount and type of construction traffic. The material used for haul roads or site access drive should be stabilization material described below. A 12-to 18-inch-thick mat of stabilization material should be sufficient for light staging areas. The stabilization material for haul roads and areas with repeated heavy construction traffic typically needs to be increased to between 18 to 24 inches. The actual thickness of haul roads and staging areas should be based on the contractor's approach to site work and the amount and type of construction traffic, and is the contractor's responsibility. The stabilization material should be placed in one lift over the prepared, undisturbed subgrade and compacted using a smooth-drum, non-vibratory roller. February 4,2016 Engineering+ Project No.70976.000 PBSEnvironmental 8 1 ` Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon IAdditionally, a geotextile fabric should be placed as a barrier between the subgrade and stabilization material. The geotextile should meet specifications ODOT SS Section 2320.10 I and SS 02320.20, Table 02320-1 for soil separation. The geotextile should be installed in conformance with ODOT SS 0350.00 —Geosynthetic Installation. I Site earthwork and subgrade preparation should not be completed during freezing conditions. We recommend the earthwork construction at the site be performed during the dry season. 1 4.2.2 Dry Weather Conditions Medium to high plasticity clay subgrade soils remaining beneath footings, slabs, or pavements should not be allowed to dry significantly. Clay soils should be covered within 4 I hours of exposure by 4 inches of crushed rock or plastic sheeting during the dry season. Exposure of these materials should be coordinated with the geotechnical engineer so that the subgrade suitability can be evaluated prior to being covered. I4.3 Excavation All excavations should be made in accordance with applicable Occupational Safety and Health I Administration (OSHA) and State regulations. The contractor is solely responsible for adherence to the OSHA requirements. Trench cuts should stand relatively vertical to a depth of approximately four feet bgs, provided no groundwater seepage is present in the trench walls. IOpen excavation techniques may be used in the clay and silt, provided the excavation is ' configured in accordance with the OSHA requirements, groundwater seepage is not present, and with the understanding that some sloughing may occur. The trenches should be flattened if I sloughing occurs or seepage is present. If shallow groundwater is observed during construction, use of a trench shield or other approved temporary shoring is recommended for cuts that extend below groundwater seepage, or if vertical walls are desired for cuts deeper than four feet bgs. If dewatering is used, we recommend that the type and design of the dewatering system be the I responsibility of the contractor, who is in the best position to choose systems that fit the overall plan of operation. The near-surface soils at the site can be excavated with conventional earthwork equipment. Sloughing and caving should be anticipated. I4.4 Slopes If the project will include slopes or open excavation, temporary and permanent cut slopes up to I 10 feet high may be inclined at 1.5H:1V and 2H:1 V, respectively. Access roads and pavements should be located at least five feet from the top of temporary slopes. Surface water runoff should be collected and directed away from slopes to prevent water from running down the face. 1 4.5 Structural Fill The extent of site grading is currently unknown; however, we estimate cuts and fills will be I limited in depth/thickness to less than 5 feet. Structural fill, including base rock, should be placed over subgrades that have been prepared in conformance with the Site Preparation and Wet-Weather/Wet-Soil Conditions sections of this report. Structural fill material should consist of I relatively well-graded soil, or an approved rock product that is free of organic material and debris, and contains particles not greater than 4-inches nominal dimension. 4.5.1 On-Site Soil IOn-site soils encountered in our explorations are generally suitable for placement as structural fill during moderate, dry weather when moisture content can be maintained by air drying and/or addition of water. The fine-grained fraction of the site soils are moisture I February 4,2016 Engineering+ Project No.70976.000 IPBS Environmental 9 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon sensitive, and during wet weather, may become unworkable due to excess moisture. In order to reduce moisture content, some aerating and drying of fine-grained soils may be required. However, due to the difficulty required to dry fine-grained soils to near optimum moisture content, re-use of native soil as structural fill may not be feasible except during dry summer months. Even then, it may require several days of constant mixing in order to achieve the desired moisture content. If used as fill for mass grading, the on-site material should be free of any organic or deleterious material with grain size less than 4-inches in diameter. The fine-grained material should be placed in lifts with a maximum uncompacted thickness of approximately 8 inches and compacted to at least 92 percent of the maximum dry density, as determined by ASTM D 1557. 1 4.5.2 Borrow Material Borrow material for general structural fill construction should meet the requirements set forth in ODOT SS 00330.12— Borrow Material. When used as structural fill, borrow material should be placed in lifts with a maximum uncompacted thickness of approximately 8 inches and compacted to not less than 92 percent of the maximum dry density, as determined by ASTM D 1557. 4.5.3 Select Granular Fill Selected granular backfill used during periods of wet weather for structural fill construction , should meet the specifications provided in ODOT SS 00330.14— Selected Granular Backfill. The imported granular material should be uniformly moisture conditioned to within about 2 percent of the optimum moisture content and compacted in relatively thin lifts using suitable mechanical compaction equipment. Selected granular backfill should be placed in lifts with a maximum uncompacted thickness of 8 to 12 inches and be compacted to not less than 95 percent of the maximum dry density, as determined by ASTM D 1557. 4.5.4 Crushed Aggregate Base Crushed aggregate base course below floor slabs, spread footings, and asphalt concrete I pavements should be clean, crushed rock or crushed gravel that contains no deleterious materials and meets the specifications provided in ODOT SS 02630.10— Dense-Graded Aggregate, and have less than 5 percent by weight passing the US Standard No. 200 Sieve. I The crushed aggregate base course should be compacted to at least 95 percent of the maximum dry density, as determined by ASTM D 1557. 4.5.5 Utility Trench Backfill I Pipe bedding placed to uniformly support the barrel of pipe should meet specifications provided in ODOT SS 00405.12 —Pipe Zone Bedding. The pipe zone that extends from the top of the bedding to at least 8 inches above utility lines should consist of material prescribed by ODOT SS 00405.13— Pipe Zone Material. The pipe zone material should be compacted to at least 90 percent of the maximum dry density, as determined by ASTM D 1557, or as required by the pipe manufacturer. Under pavements, paths, slabs, or beneath building pads, the remainder of the trench backfill should consist of well-graded granular material with less than 10 percent by weight passing the US Standard No. 200 Sieve, and should meet standards prescribed by ODOT SS 00405.14—Trench Backfill, Class B or D. This material should be compacted to at least 92 percent of the maximum dry density, as determined by ASTM D 1557 or as required by the pipe manufacturer. The upper two feet of the trench backfill should be compacted to at least 95 percent of the maximum dry density, as determined by ASTM D 1557. Controlled February 4,2016 Engineering+ Project No.70976.000 PBSEnvironmental 10 PBS Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon low-strength material (CLSM), ODOT SS 00405.14 —Trench Backfill, Class E, can be used as an alternative. Outside of structural improvement areas (e.g., pavements, sidewalks, or building pads), trench material placed above the pipe zone may consist of general structural fill materials that are free of organics and meet ODOT SS 00405.14—Trench Backfill, Class A. This general trench backfill should be compacted to at least 90 percent of the maximum dry density, as determined by ASTM D 1557, or as required by the pipe manufacturer or local jurisdictions. 4.5.6 Stabilization Material Stabilization rock should consist of pit- or quarry-run rock that is well-graded, angular, crushed rock consisting of 4- or 6-inch-minus material with less than 5 percent passing the US Standard No. 4 Sieve. The material should be free of organic matter and other deleterious material. ODOT SS 00330.16— Stone Embankment Material can be used as a general specification for this material with the stipulation of limiting the maximum size to 6 inches. 5.0 ADDITIONAL SERVICES AND CONSTRUCTION OBSERVATIONS In most cases, other services beyond completion of a geotechnical engineering report are necessary or desirable to complete the project. Occasionally, conditions or circumstances arise that require the performance of additional work that was not anticipated when the geotechnical report was written. PBS offers a range of environmental, geological, geotechnical, and construction services to suit the varying needs of our Clients. PBS should be retained to review the plans and specifications for this project before they are finalized. Such a review allows us to verify that our recommendations and concerns have been adequately addressed in the design. Satisfactory earthwork performance depends on the quality of construction. Sufficient observation of the contractor's activities is a key part of determining that the work is completed in accordance with the construction drawings and specifications. We recommend that PBS be retained to observe general excavation, stripping, fill placement, and footing and pavement subgrades. Subsurface conditions observed during construction should be compared with those encountered during the subsurface explorations. Recognition of changed conditions requires experience; therefore, qualified personnel should visit the site with sufficient frequency to detect whether subsurface conditions change significantly from those anticipated. 1 6.0 LIMITATIONS This report has been prepared for the exclusive use of the addressee, and their architects and engineers, for aiding in the design and construction of the proposed development and is not to be relied upon by other parties. It is not to be photographed, photocopied, or similarly reproduced, in total or in part, without express written consent of the Client and PBS. It is the addressee's responsibility to provide this report to the appropriate design professionals, building officials, and contractors to ensure correct implementation of the recommendations. The opinions, comments, and conclusions presented in this report are based upon information derived from our literature review, field explorations, laboratory testing, and engineering analyses. It is possible that soil, rock, or groundwater conditions could vary between or beyond the points explored. If soil, rock, or groundwater conditions are encountered during construction that differ February 4,2016 Engineering+ Project No.70976.000 PBSEnvirommentai 11 Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon from those described herein, the Client is responsible for ensuring that PBS is notified immediately so that we may reevaluate the recommendations of this report. Unanticipated fill, soil and rock conditions, and seasonal soil moisture and groundwater variations ! are commonly encountered and cannot be fully determined by merely taking soil samples or soil borings and test pits. Such variations may result in changes to our recommendations and may require additional funds for expenses to attain a properly constructed project. Therefore, we111 recommend a contingency fund to accommodate such potential extra costs. The scope of services for this subsurface exploration and geotechnical report did not include I environmental assessments or evaluations regarding the presence or absence of wetlands or hazardous substances in the soil, surface water, or groundwater at this site. If there is a substantial lapse of time between the submission of this report and the start of work at the site, if conditions have changed due to natural causes or construction operations at or adjacent to the site, or if the basic project scheme is significantly modified from that assumed, this report should be reviewed to determine the applicability of the conclusions and recommendations presented herein. Land use, site conditions (both on and off site), or other factors may change over time and could materially affect our findings. Therefore, this report should not be relied upon after three years from its issue, or in the event that the site conditions change. I I I I I I I I February 4,2016 PBS + Project No.70976.000 PBSEnvironmental 12 1 ' Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon I7.0 REFERENCES I Beeson, M.H., Tolan, T.L., and Madin, I.P., 1989, Geologic map of the Lake Oswego quadrangle, Clackamas, Multnomah, and Washington counties, Oregon: Oregon Department of Geology and Mineral Industries, Geological Map Series 59, scale 1:24,000 IODOT SS. (2014, updated 2015). Oregon Standard Specifications for Construction. Salem, Oregon. Oregon Department of Transportation. IOregonHazvu. Oregon Department of Geology and Mineral Industries. Portland, OR OSSC (2014) Oregon Structural Specialty Code (OSSC). Based on IBC. (2012). International IBuilding Code. Country Club Hills, IL: International Code Council, Inc. Schlicker, H.G., Deacon, R.J., 1967, Engineering geology of the Tualatin Valley region, Oregon: Oregon Dept. Geology and Mineral Industries Bull. 60, 103 p. I I I I I I 1 I I I February 4,2016 Engineering+ Project No.70976.000 1 PBS Environmental 13 I" W CD LL M NUM N MIN NO M ON NM MIM MO U' INMI NW NO 1.01 NM MN NM NO I , g • ,, ,,,,f,K%N."ip;t.,,-,......., ,,,,-,,, tr,... A ---4;13. , 17 , ., I s., ai$i° ..-- '''.3 .3 �' `' }t 4y z ` i. a 't a x7 ' b I. < ii A 4# , r :f . .:.,,,,,...,. ark...,4„,:A,. 4-0*,,,- ,:,;„-',‘,„ . ‘,V,:„.„/ 3 1,,,„ `' ' 1i f S 'f I .tt,FA,-446.- .1 1:!-Sit ig.,...14-.„ ..-7k., - „,„ ,,,,41t7 Y fti k it a * 34 11MuleAvr 71.4. t fit f ,i = �, :,t%1,."1: < ;, PROJECT LOCATION �� *ia.. 2�.,:-. #t . `3 _ a< aNr• y{M44 •=1 1 .�a s",=,-., ,Nt."1-'-.4%.,. - 'vis,.., - W Y. ftliw----7.-Awi4it„ ' .--. .„...._ \, .. ,' ' tot .1.4-: ¢ � ::Al ems* I :, C x', �,�, + a R, F.`v 'FE`�,+' it i -it {� • t ,. 1 * f *1: > • ito I s _ LI 1. „t.x# + J ' � x sr a f ''y ,..:. `3 y� , ;< ,L 4tr , rotor. ,: i I W •* H'< '$ '!' < Ste” E'`<' t --.. i I {E N�k mgr- .._ iry 1" `^,y --- e," h ; C J. { A w ^"�-"_._'� - i£ s! :� „+ rI —' r . } I - § .'%;+v C+ i ,,c, r4.. gA . ,,:.,; v a F,r I :9wL.i3c.k at`.- .rd, r .Sty SOURCE.USGS LAKE OSWEGO OR QUADRANGLE 1981, PHOTO REVISED 1984 • SITE PORTLAND 111 EUGENE , ' 0' 1,000' 2,000' 4,000' SCALE: 1"=2,000' OREGON PREPARED FOR:DAVCKOR LLC I I PROJECT# FIGURE 70976.001 VICINITY MAP DATE PROPOSED HOTEL DEVELOPMENT 1 i , pBS FEB 2016 TIGARD, OREGON Q 7 ol, t;- L")artmot,,hryllt,,,,,(400tech,GeoL)vvg,70976 000 Orr', )( FE ' -'1 *, , trf) 71 G) , ,,.,,,,,,, ',/.1,,P*'"1 '4,41',, --.1 -a ,44 ,',i,4';',,1 ,,', ; ,,*4 c-' '' ,'; „,.,, i'..', , -11 (D 73 CO C::I .., 4 C' 1 '4'14' ',. ' r eft,,4 .v r.!' 5"„*.,; ,, „iir ' s',"7 0 > 0) m z_..7zi ,.', '''°' " ' 0 " AVENUE *' a m o H , S W 70TH .444, c) , G) ,1111, 03 III ' 9'; JJ•jtj u.,u 1 0 I -H 1 It.:1.1 0 1 Z gill: . ,. ts, 0 --I M 5 0 (I) 0 -,-, . , r- U *34, la X 0 r— t,'"iiA inm . ** 'l l' ‘1**; '''''0111.` 7f"'"*"'''''r';:r'..,,'..,'"''94•''"'"' :'' " ,""','4,' '`"'''';',#"" ,,' ,4, ', "21 ,„4" ry 7'..,k a„err",,,,,,,,,,-„* 44,44,,,,,4 , ". 1 ,'*,,,li 0 < ---- , ,A1 4 40, ' ,j,,..asilit,,,,,4, °•01,,4* ' ,b,,,4'.4 ' "1„,..,°,,--f0,04a a0.4 a° ,..' - 4.4 4° . 7°- ° * 6 4'1 'ifil *,17, '' ' ; I ' ''''l ' 0 M Z z r- e,,,, ,....,1 , ,,,,,,,,,,„,.,,,,,$,,„„,,,,,„,,4,44,.04,,, , , , _._ .,_. .,„,,,..,, -„•'4411,4k0),'" .,;:',,, ','-'`... A ' "''''r4t,,:°:,' ,;.14%f' "°,,,,,4 , 4, -CI P. / M Z /CI* CID I , —I 9 koLVIA 1 -t, aoa—N . ')3'1 " 70 a) m .?4'" co ,ot 1...../1. m (-) IL c) S W 69TH AuanVENU_E ..., ii 0 co Cl -n 0 NIP c) 0 ..... a) 1\4) C X c2 NIB III. all. will 1111111 m r- 1111 n *INN MIMI lila ill' 111111 gill °Ile lig. — lila 11111 illif 1 1 1 1 i i 1 ' APPENDa% A Field t 1 A 1 1 Geotechnical Engineering Report Proposed Hotel Development Tigard, Oregon IAPPENDIX A— FIELD EXPLORATIONS I A1.0 GENERAL PBS explored the subsurface conditions at the project site by advancing six borings to depths of up to 36.5 feet bgs. The approximate locations of the explorations are shown on Figure 2, Site Plan. I The procedures and techniques used to drill the borings, collect samples, and other field techniques, are described in detail in the following paragraphs. Unless otherwise noted, all soil sampling and classification procedures followed local engineering practices that are in general I accordance with relevant ASTM procedures. "General accordance" means that certain local and common drilling and descriptive practices and methodologies have been followed. A2.0 BORINGS IA2.1 Drilling Borings were advanced with a truck-mounted CME-850 drill rig provided and operated by I Western States Soil Conservation, Inc. of Hubbard, Oregon, using mud rotary and hollow-stem auger drilling techniques. The borings were observed by a PBS geotechnical staff member, who maintained a detailed log of the subsurface conditions and materials encountered during the course of the work. I A2.2 Sampling Disturbed soil samples were taken in the borings at selected depth intervals. The samples were Iobtained using a standard 2-inch outside diameter(OD), split-spoon sampler following procedures prescribed for the standard penetration test (SPT). The sampler is driven 18 inches into the soil using a 140-pound hammer dropped 30 inches. The number of blows required to I drive the sampler the last 12 inches is defined as the standard penetration resistance (N-value). The N-value provides a measure of the relative density of granular soils such as sands and gravels, and the consistency of cohesive soils such as clays and plastic silts. The disturbed soil I samples were examined by a member of the PBS geotechnical staff, and then sealed in plastic bags for further examination and physical testing in our laboratory. I A2.3 Boring Logs The boring logs show the various types of materials that were encountered in the borings and the depths where the materials and/or characteristics of these materials changed, although the changes may be gradual. Where material types and descriptions changed between samples, I the contacts were interpreted. The types of samples taken during drilling, along with their sample identification number, are shown to the right of the classification of materials. The and natural water(moisture) contents are shown further to the right. IN-values A3.0 MATERIAL DESCRIPTION Initially, soil samples were classified visually in the field. Consistency, color, relative moisture, Idegree of plasticity, and other distinguishing characteristics of the soil samples were noted. Afterward, the samples were reexamined in the PBS laboratory, various standard classification tests were conducted, and the field classifications were modified where necessary. The terminology used in the soil classifications and other modifiers are defined in Appendix A, Table A-1, Terminology Used to Describe Soil. I I February 4,2016 Project No.70976.000 I A-1 Table A-1 Terminology Used to Describe Soil PBS 1of2 Soil Descriptions I Soils exist in mixtures with varying proportions of components. The predominant soil, i.e., greater than 50 percent based upon total dry weight, is the primary soil type and is capitalized in our log descriptions, e.g., SAND, GRAVEL, SILT or CLAY. Lesser percentages of other constituents in the soil mixture are indicated by use of modifier words in general accordance with the Visual-Manual Procedure (ASTM D2488-06). "General Accordance" means that certain local and common descriptive practices have been followed. In accordance with ASTM D2488-06, group symbols (such as GP or CH) are applied on that portion of the soil passing the 3-inch (75mm) sieve based upon visual examination. The following describes the use of soil names and modifying terms used to describe fine-and coarse-grained soils. Fine-Grained Soils (More than 50%fines passing 0.075 mm,#200 sieve) I The primary soil type, i.e. SILT or CLAY is designated through visual — manual procedures to evaluate soil toughness, dilatency, dry strength, and plasticity. The following describes the terminology used to describe fine-grained soils, and varies from ASTM 2488 terminology in the use of some common terms. 1 PlastPrimary soil NAME, adjective and symbols Descriptiyon IndPlaex (P ) Description Index (PI) ORGANIC SILT CLAY SILT & CLAY ML & MH CL&CH OL & OH SILT Organic SILT Non plastic 0 31 SILT Organic SILT Low plasticity 4 10 SILT/ Elastic Lean CLAY Organic clayey SILT Medium Plasticity 10—20 SILT Elastic SILT Lean/Fat CLAY Organic silty CLAY High Plasticity 20—40 III Elastic SILT Fat CLAY Organic CLAY Very Plastic >40 Modifying terms describing secondary constituents,estimated to 5 percent increments,are applied as follows: I Description %Composition With sand; with gravel (combined total greater than 15% but less than 15%to 30% 30%, modifier is whichever is greater) (combined or gravelly ( ined total greater than 30% but less than 30%to 50% 50%, modifier is whichever is greater) Borderline Symbols, for example CH/MH, are used where soils are not distinctly in one category or where I variable soil units contain more than one soil type. Dual Symbols, for example CL-ML, are used where two symbols are required in accordance with ASTM D2488. Soil Consistency. Consistency terms are applied to fine-grained, plastic soils (i.e., PI >7). Descriptive terms are based on direct measure or correlation to the Standard Penetration Test N-value as determined by ASTM D1586- 84, as follows. Note, SILT soils with low to non-plastic behavior(i.e. PI < 7)are classified using relative density. I Consistency Unconfined Compressive Strength Term SPT N-value tsf kPa Very soft Less than 2 Less than 0.25 Less than 24 Soft 2 4 0.25 0.5 24 48 Medium stiff 5 8 0.5 1.0 48 96 Stiff9— 15 1.0 2.0 96 192 Very stiff_... 16—.30 __. .... 2.0 4.0 192 383 Hard Over 30 Over 4.0 Over 383 I . Table A-1 I PBS Terminology Used to Describe Soil 2 of 2 1 Soil Descriptions 1 Coarse - Grained Soils (less than 50%fines) Coarse-grained soil descriptions, i.e., SAND or GRAVEL, are based on that portion of materials passing a 3-inch (75mm) sieve. Coarse-grained soil group symbols are applied in accordance with ASTM D2488-06 based upon Ithe degree of grading, or distribution of grain sizes of the soil. For example, well graded sand containing a wide range of grain sizes is designated SW; poorly graded gravel, GP, contains high percentages of only certain grain sizes. Terms applied to grain sizes follow. Material Particle Diameter Inches Millimeters Sand (S) 0.003 -0.19 0 075 4 8 Gravel G 0.19 3.0 4.8 75 Additional Constituents Cobble 3.0:71-2 Boulder 12- 120 300- 3050 IThe primary soil type is capitalized, and the amount of fines in the soil are described as indicated by the following examples. Other soil mixtures will provide similar descriptive names. Example: Coarse-Grained Soil Descriptions with Fines o 0 5/o to less than 15% fines 15% to less than 50% (Dual Symbols) fines GRAVEL with silt, GW-GM Silty GRAVEL: GM SAND with clay, SP-SC Silty SAND: SM IAdditional descriptive terminology applied to coarse-grained soils follow. Example: Coarse-Grained Soil Descriptions with Other Coarse-Grained Constituents Coarse-Grained Soil Containing Secondary Constituents With sand or with gravel > 15% sand or gravel With cobbles; with boulders Any amount of cobbles or boulders. ICobble and boulder deposits may include a description of the matrix soils, as defined above. Relative Density terms are applied to granular, non-plastic soils based on direct measure or correlation to Ithe Standard Penetration Test N-value as determined by ASTM D1586-84. Relative Density Term SPT N-value IVery loose 0 -4 Loose 5 - 10 Medium dense 11 - 30 Dense 31 - 50 ____ Very dense > 50 I Table A-2 P B S Key To Test Pit and Boring Log Symbols Engineering+ Environmental SAMPLING DESCRIPTIONS I a. co Q. ° -- I c co o°j ai o : h0 _\k. F� �co c i s co ¢') � � 0 40 .o h clo a ° 2 a.) 41- 6 ^ O O � � � ..1,- ..\ � . i � Q LI/ fill /Ui o C...) 'i /f /I vN 111 11_1] kl I I N 11 n sz Y LOG GRAPHICS Soil and Rock Sampling Symbols Instrumentation Detail I Lithology Boundary- -•- - •-•4 Ground Surface . .7....., .':' separates distinct units ;,. Well co =f;-: / (i.e. Fill,Alluvium, Sample Cap i Bedrock Fm)(at approx. Recovery Sample Well Seal H depth indicated) Interval ---- Well Pipe U ° Soil Type or Material TypeI Piezometer o / Change Boundary-separates - - -changes in soil-type and `� ':p Well Screen 0 material-type within the same Sampler ----- ,•• -----Piezometer ________ •litholgic unit(at approx. Type -- __- depth indicated) "-*---Bottom of Hole I Geotechnical Testing/Acronym Explanations PP Pocket Penetrometer LL Liquid Limit I DD Dry Density ATT Atterberg Limits DCP Dynamic Cone Penetrometer SIEV Sieve Gradation TOR Torvane CBR California Bearing Ratio CON Consolidation 00 Organic Content DS Direct Shear RES Resilient Modulus P200 Percent Passing U.S. Standard No. 200 Sieve VS Vane Shear UC Unconfined Compressive Strength HYD Hydrometer Gradation PL Plasticity Limit bgs Below ground surface PI Plasticity Index MSL Mean Sea Level I I 1Note:Details of soil and rock classification systems are available on request. Rev.02/23/15 I II A T MT PROPOSED HOTEL DEVELOPMENT 4412 SW Corbett Avenue TIGARD,OREGON BORING B-1 — Portland,Oregon 97239 I p Bs Phone:503.248.1939 FaK 866.727.0140 PBS PROJECT NUMBER: 70976.000 APPROX.BORING B-1 LOCATION: 45.43495,-122.74847 Engineering+ Environmental w A BLOW COUNT 1 0 DEPTH T oMATERIAL DESCRIPTION o a.a 1 z Li; O. ,n1-- 4:*DYNAMIC CONE PENETROMETER INSTALLATION AND COMMENTS FEET S3 NOTE:Lines representing the interface between soil/rock units of W 0-Z •MOISTURE CONTENT% 0 differing description are apprcodmate only,inferred where I- 2 co [OD RQD% EDCORE REC% < Surface Conditions:Grass / 0.0 between samples,and may indicate gradual transition. -77- -7i - \ TOPSOIL(2 INCHES) 0.2 (1) 0 50 100 Medium stiff brown LEAN CLAY(CL);medium - plasticity;moist I 2.0 - I 1 I - — Infiltration testing completed becomes stiff at 4.75 feet bgs 1 6.0 - 11 `,1, A • — — 6.5 IBoring completed at 6.5 feet bgs;boring backfilled with bentonite chips to existing ground surface. 8.0 - II I1 0.0 - - I 12.0 - - I g€ as 5 ic-i , I 2 Fc 14.0 - - a. }-- - 0 q a UI I 0 e. k 16.0 - 0 Irf! 0 g , 18.0 - - - § i <0 0 <5 9 20.o O 0 50 100 §: DRILLING METHOD:Hollow-Stem Auger BIT DIAMETER:4 7/8 inches I 2 DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE Al LOGGED BY:T.RHO LOGGING COMPLETED:11/23/15 Page 1 of 1 I PROPOSED HOTEL DEVELOPMENT BORING B-2 4412 SW Corbett Avenue TIGARD,OREGON Portland,Oregon 97239 PBS Phone:503.248.1939 APPROX.BORING B-2 LOCATION: 1 Fax 866.727.0140 PBS PROJECT NUMBER: 45.43533,-122.74848 Engineering+ 70976.000 Environmental a.p A BLOW COUNT C9 w O DYNAMIC CONE INSTALLATION AND DEPTH =c9 MATERIAL DESCRIPTION F Z 0- PENETROMETER COMMENTS FEET NOTE:Lines representing the interface between soil/rock units of 0 w a-Q ♦MOISTURE CONTENT% 0 differing description are approbmate only,inferred where I-- ¢co ®RQD% CORE REC% Surface Conditions:Grass between samples,and may indicate gradual transition. rn 0 50 100 1 0.0 r TOPSOIL(2 INCHES) i 0.2 Medium stiff brown LEAN CLAY(CL);medium plasticity;moist I 2.0 / — ! ' 1 I 4.0 _ I becomes stiff Infiltration testing completed 14 at 4.95 feet bgs I 6.0 — Al - 6.5 Boring completed at 6.5 feet bgs;boring backfilled with bentonite chips to existing I - ground surface. _ 8.0 — — 1 10.0 — — I I 12.0 — — — -4 I a - Ui 0 a E 14.0 — — 6 0 a o ti I a a 16.0 — — 6 fn U. n. d t- OS�o O m 18.0 — _ h i I 20.0 Z 0 50 100 DRILLING METHOD:Hollow-Stem Auger BIT DIAMETER:4 7/8 inches y, DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE A2 LOGGED BY:T.Rikli LOGGING COMPLETED:11/23/15 Page 1 of 1 I • PROPOSED HOTEL DEVELOPMENT 4412 SW Corbett Avenue TIGARD,OREGON BORING B-3 Portland,Oregon 97239 I P B S Phone:503.248.1939 APPROX.BORING B 3 LOCATION: Bs Fax 866.727.0140 PBS PROJECT NUMBER: Engineering+ 70976.000 45.43540,-122.74786 Environmental a p A BLOW COUNT DEPTH = MATERIAL DESCRIPTION F z PENETROMETER INSTALLATION AND a 0 a a COMMENTS FEET NOTE:Lines representing the interface between soil/rock units of ww a< •MOISTURE CONTENT% C7 differing description are apprordmate only,inferred where p I- Q co ®RQD% CORE REC% Surface Conditions:Grass between samples,and may indicate gradual transition. Cl) 7 50 100 0.0 �jr~• \TOPSOIL(2 INCHES) ` 0.2 j Medium stiff brown LEAN CLAY(CL);medium plasticity;moist I (7)" : • - I 4.0 — — CON - 450 psi for 12 inches;500 psi for 6 inches;600 psi for 6 inches 6.0 — - I - ATT - LL=40 PL=23 becomes stiff A t—�--I PI=17 8.0 — . Driller switched to drag bit at I 7 feet � I 10.0 / — •4 co 12.0 — Ie w / - oI � F14.0 �j — I- 0 becomes medium stiff in 11 a 16.0 �% — = 0m m F / I iE.', 180 6 2 j/ 2 20.0 o 0 50 100 T DRILLING METHOD:Mud Rotary BIT DIAMETER:4 7/8 inches DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE A3 LOGGED BY:T.Rikli LOGGING COMPLETED:11/23/15 Page 1 of 2 , , • PROPOSED HOTEL DEVELOPMENT I 4412 SW Corbett Avenue TIGARD,OREGON BORING B-3 Portland,Oregon 97239 (continued) PBSPhone:503.248.1939 Fax:866.727.0140 PBS PROJECT NUMBER: APPROX.BORING B-3 LOCATION: Engineering+ 70976.000 4543540,-122.74786 1 Environmental t1,1 a.o A BLOW COUNT MATERIAL DESCRIPTION x 2 w +DYNAMIC CONE INSTALLATION AND DEPTH it(.9 }-- E 0 i a, PENETROMETER COMMENTS FEET El NOTE:Lines representing the interface between soil/rock units of193 ci) El-2 •MOISTURE CONTENT% 0 differing description are apprcudmate only,inferred where ° iii2 2(/) OE RQD% 177ICORE REC% Surface Conditions:Grass < between samples,and may indicate gradual transition, (.0 0 50 100 20.0 Very stiff brown gray orange LEAN CLAY I (CL);low plasticity;moist 20 F A 22.0 — — — I ), 24.0 II 21 I1° A I . 26.0 — . I 28.0 — — I 30.0 — i 24 F • 1 32.0 -— ec 4:5 ; a ilii 1- z I - re 34.0 a. E 0. o w 0 a.' I 2 F20 • 36.0 — ci _ 36 5 Boring completed at 36.5 feet bgs;boring (7. 0 backfilled with bentonite chips to existing I ti. ground surface. 2,3 0 38.0 — C 0 — t 0 TV3 - '- I § le. r_ 0 9 40.0 I 0 0 50 100 g DRILLING METHOD:Mud Rotary BIT DIAMETER:47/8 inches 2 DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE A3 LOGGED BY:T.Rikli LOGGING COMPLETED:11/23/15 Page 2 of 2 PROPOSED HOTEL DEVELOPMENT 4412 SW Corbett Avenue TIGARD,OREGON BORING B-4 Portland,Oregon 97239 I P B C Phone:503.248.1939 APPROX.BORING B-4 LOCATION: V�.7 Fax 866.727.0140 PBS PROJECT NUMBER: Engineering+ 70976 000 45.43504,-122.74802 Environmental I DEPTH a a o A BLOW COUNT MATERIAL DESCRIPTION x a.w O DYNAMIC CONE PENETROMETER INSTALLATION AND FEET o a 1= w a COMMENTS NOTE:Lines representing the interface between soil/rock units of W w J s •MOISTURE CONTENT 0 differing description are approximate only,inferred where t— CO ®RQD% ®CORE REC% Surface Conditions:Grass I between samples,and may indicate gradual transition. 0 50 100 0.0 `TOPSOIL(2 INCHES) i 02 Very stiff brown LEAN CLAY(CL);medium plasticity;moist I I I 7 =8 cn I4.0 — — — I19 6.0 — ♦ • —1 becomes stiff $o — !cc;)? ♦3 I I 10.0 — co A I 12.0 — 1 ai W o j/ a 14.0 — o _ 0. I ow becomes very stiff,brown gray orange �s 0 16.0 — — COa c O E., 18.0 - _ ij I O 2 20.0 0 0 50 100 f- DRILLING METHOD:Mud Rotary BIT DIAMETER:4 7/8 inches i °m DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE A4 LOGGED BY:T.Rikli LOGGING COMPLETED:11/23/15 Page 1 of 2 PROPOSED HOTEL DEVELOPMENT I 4412 SW Corbett Avenue TIGARD,OREGON BORING B-4 Portland,Oregon 97239 (continued) PBS Phone:503.248.1939 APPROX.BORING B-4 LOCATION: L.7 Fax 866.727.0140 PBS PROJECT NUMBER: 45.43504,-122.74802 I Engineering+ 70976.000 Environmental ea A BLOW COUNT 02 a w O DYNAMIC CONE INSTALLATION AND oDEPTH = MATERIAL DESCRIPTION ii Z a PENETROMETER COMMENTS FEET O� NOTE:Lines representing the interface between soil/rock units of o w _JillQ •MOISTURE CONTENT% 0 differing description are approximate only,inferred where 1- Q di ®RQD% ®CORE REC% Surface Conditions:Grass between samples,and may indicate gradual transition. rn 0 50 100 1 20.0 V Very stiff brown gray orange LEAN CLAY (CL);medium plasticity;moist21 I 22.0 - . I 24.0 - - I becomes medium stiff 11'' 7 I 26.0 - — 28.0 - — j I 30.0 becomes very stiff 1 16 Iliz(ig A • i 32.0 - w a J o Z I a 34.0 Q. - GI 0 w Ui becomes hard I J g 0 ti II cob) A 36.0 - m Boring completed at 36.5 feet bgs;boring 36.5 0 - backfilled with bentonite chips to existing I ce ground surface. - O'''' 0 m 38.0 - I 8N O OI40.0 z 0 50 100 zDRILLING METHOD:Mud Rotary BIT DIAMETER:4 7/8 inches li DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE A4 LOGGED BY:T.Rikli LOGGING COMPLETED:11/23/15 Page 2 of 2 I . , , —...—.. --, PROPOSED HOTEL DEVELOPMENT 4412 SW Corbett Avenue TIGARD,OREGON BORING 6-5 ----- Portland,Oregon 97239 I P Bs Phone:503.248.1939 Engineering+ Fax 866.727.0140 PBS PROJECT NUMBER: 70976.000 APPROX.BORING B-5 LOCATION: 45.43471,-122.74854 Environmental UJ A BLOW COUNT I F.. DEPTH 'o PENETROMETER MATERIAL DESCRIPTION o 11-cp L 1 z ...., 0 DYNAMIC CONE INSTALLATION AND COMMENTS FEET 1 9 NOE Lines Ines representing the interface between soil/rock units of 0U-I ul 0-2 < IP MOISTURE CONTENT% o differing description are approximate only,inferred where I— 2 co El]RQD% CORE REC% < Surface Conditions:Grass 1 0.0 between samples,and may indicate gradual transition. .LA• TOPSOIL(6 INCHES) u) 0 50 100 0.5 $ Stiff brown CLAY(CL);medium plasticity;moist 0 I •A 4 _ • 4 • 2.0 v - •4 • 4 • I •4 • 4 • 4 • •4 • [ 12 ch,- A • •4 • •4 • •4 I 4.0 • •4 • •4 FILL — — — 4 • •• becomes very stiff I 6.0 I - •, — I CV 1 (/) A19 — •4I • _ • I • •4 • -•41 • •4 • 4 • becomes hard I]2 50/3"A 8.0 '4 _ _ Is' •ibfr' Very dense clayey GRAVEL(GC);medium 8.5 Difficult drilling at 8.5 feet bgs -•• plasticity;coarse,angular to subangular gravel; - ,• _i . Caving between 8.5 and 14 moist feet bgs I •', 10.0 •••Al° *40 - CO • . co • :ion-A • , *• • I •, •,,,- ,47 12.0 • A I :, */ it! • . • , . •. i14.0 • '' Stiff gray with red-brown mottles LEAN CLAY 14.0 Q. Easier drilling at 14 feet bgs (CL);high plasticity;moist d w 111 O ATT LL=48 16.0.62 2 in 15 PL=25 = I T F.J .± 1-- . 2 .• 18.0 PI23 , 1 ,7> ,.(. — — I ?, 20.0 /5 o a 50 10, g DRILLING METHOD:Mud Rotary BIT DIAMETER:47/8 inches FIGURE A5 I co DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 LOGGED BY:M.Swank LOGGING COMPLETED:11/24/15 Page 1 of 2 PROPOSED HOTEL DEVELOPMENT BORING B-5 I 4412 SW Corbett Avenue TIGARD,OREGON Portland,Oregon 97239 (continued) PBSPhone:503.248.1939 APPROX.BORING B-5 LOCATION: a J Fax:866.727.0140 PBS PROJECT NUMBER: 45.43471,-122.74854 Engineering+ 70976.000 Environmental tii o_p BLOW COUNT I MATERIAL DESCRIPTION = z I-1±13 O DYNAMIC CONE INSTALLATION AND DEPTH =c7 1-- 1= w PENETROMETER COMMENTS FEET NOTE:Lines representing the interface between soilrock units of air).* w o Q •MOISTURE CONTENT O differing description are approamate only,inferred where H Q ROD% CORE REC% Surface Conditions:Grass between samples.and may indicate gradual transition. LO 0 50 100 I 20.0 %// Very stiff gray and brown with black specks jLEAN CLAY(CL);high plasticity;moist11is coI 22.0 — — I 24.0 — 1 _///-/1-.. 25.0 Hard gray and light brown SILT(ML);low plasticity; moistv� Ilk 33 26.0 — — 1I 28.0 — — I 30.0 — I 34 II coot) A - 31.5 I Boring completed at 31.5 feet bgs. Boring 32.0 — backfilled with bentonite chips to existing — — — it r ground surface. _ N w r 0 0 a 34.0 — I — o d w 0 El_ I a 36.0 — — 0 0 m a. aI 0 Oe m m 38.0 — — —t 01 9 40.0 0 50 100 (2 DRILLING METHOD:Mud Rotary BIT DIAMETER:4 7/8 inches FIGURE A5 °m DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 paw 2 of 2 LOGGED BY:M.Swank LOGGING COMPLETED:11/24/15 IPROPOSED HOTEL DEVELOPMENT 4412 SW Corbett Avenue TIGARD,OREGON BORING B-6 Portland,Oregon 97239 I PBS Phone:503.248.1939 APPROX.BORING B 6 LOCATION: V Fax:866.727.0140 PBS PROJECT NUMBER: Engineering+ 70976.000 45.43469,-122.74811 Environmental I DEPTH a wap ♦BLOW COUNT MATERIAL DESCRIPTION s z J O DYNAMIC CONE PENETROMETER INSTALLATION AND o a t= J a COMMENTS FFEET NOTE:Lines representing the interface between soil/rock units of W w 0- •MOISTURE CONTENT% 0 differing description are approximate only,inferred where p t- Q(Qi ®ROD% CORE REC% Surface Conditions:Grass ' 0.0 - between samples,and may indicate gradual transition. 0 50 100 —.Tr.— TOPSOIL(6 INCHES) . — Medium stiff brown SILT(ML);low plasticity; 0.5 .• moist• = •♦ 2.0 .: — _ .• • ♦� 7 .• !sci) A • • I 4.0 $• FILL — — . .• • becomes stiff ♦ • 10 6.0 :• co;,) ♦ • — • • 1 ♦• - O ♦• •♦ . • 8.0 44,• — M 10 ♦ ..•i Medium dense poorly graded GRAVEL(GP); 90 ;tit coarse,angular to subangular gravel;moist 10.0 ;. < — • ,.•,g Stiff brown LEAN CLAY(CL);medium 10.5 lIt .2 plasticity;moist - 12.0 — tiia 350psi for 24 inches o 14.0 ,o a. ootuj I 62 ti becomes very stiff and gray with brown mottles 18 ♦ • oo 16.0 — _ r j `,3_ - 18.0te — — N �j O 2, 20.0 / z 0 50 100 El DRILLING METHOD:Mud Rotary BIT DIAMETER:4 7/8 inches I °m DRILLED BY:Western States Soil Conservation,Inc. HAMMER EFFICIENCY PERCENT:85 FIGURE A6 LOGGED BY:M.Swank LOGGING COMPLETED:11/24/15 Page 1 of 2 MMIIIIIIIIIIIIIINIM PROPOSED HOTEL DEVELOPMENT I 4412 SW Corbett Avenue TIGARD,OREGON BORING B-6 Portland,Oregon 97239 (continued) PBS Phone:503.248.1939 APPROX.BORING B-6 LOCATION: I 1•� Fax:866.727.0140 PBS PROJECT NUMBER: 45.43469,-122.74811 Engineering+ 70976.000 Environmental A BLOW COUNT CL v ° gEJJ O DYNAMIC CONE INSTALLATION AND = DEPTH MATERIAL DESCRIPTION i t- H W a PENETROMETER COMMENTS FEET g OJ w CO a •MOISTURE CONTENT NOTE:Lines representing the interface between soil/rock units of p W Q (0 differing description are approximate only,inferred where t— Q U) fTTT1 RQD% CORE REG% Surface Conditions:Grass between samples.and may indicate gradual transition. rn 0 50 100 111 20.0 ��/� Very stiff gray and brown LEAN CLAY(CL); • oil'% medium plasticity; moistt9 II A III22.0 — 1 -j 24.0 — I - I 1 I I I I I I I LAryPPENOoratory �I% e sting I I I I I I I I I Geotechnical Engineering Report Proposed Hotel Development Tigard,Oregon APPENDIX B — LABORATORY TESTING B1.0 GENERAL Samples obtained during the field explorations were examined in the PBS laboratory. The physical characteristics of the samples were noted and the field classifications were modified where ' necessary. The testing procedures are presented in the following paragraphs. Unless noted otherwise, all test procedures are in general accordance with applicable ASTM standards. "General accordance" means that certain local and common descriptive practices and methodologies have been ' followed. B2.0 CLASSIFICATION TESTS B2.1 Visual Classification The soils were classified in accordance with the Unified Soil Classification System with certain other terminology, such as the relative density or consistency of the soil deposits, in general accordance with engineering practice. In determining the soil type (that is, gravel, sand, silt, or clay)the term that best described the major portion of the sample is used. Modifying terminology to further describe the samples is defined in Terminology Used to Describe Soil in Appendix A. B2.2 Moisture (Water) Contents Natural moisture content determinations were made on samples of the fine-grained soils (that is, clay, silts, and silty sands). The natural moisture content is defined as the ratio of the weight of water to dry weight of soil, expressed as a percentage. The results of the moisture content determinations are presented on the exploration logs in Appendix A. B2.3 Atterberg Limits Atterberg limits were determined on selected samples for the purpose of classifying soils into various groups for correlation. The results of the Atterberg limits tests, which included liquid and plastic limits, are plotted on the Atterberg Limits Test Results, Figure B1, and on the exploration logs in Appendix A. B3.0 CONSOLIDATION TEST Consolidation testing was conducted on one sample to obtain quantitative data for use in evaluating potential settlement resulting from loads imposed from proposed foundations. The test specimen was placed in a one-dimensional consolidation test apparatus (fixed ring). Loads were applied to the specimen and the resulting change in thickness of the soil sample was monitored with time. ' Upon completion of primary consolidation, the next load increment was applied. The specimen was kept moist until the first load increment was applied, at which point the specimen was inundated with water. The consolidation test curve is presented on Figure B2. The curve of the plots show the percent strain that occurred in the test specimens under various magnitudes of applied constant load. I r February 4,2016 Project No.70976.000 B-1 IMIIMMIMMIIIIII.... i ATTERBERG LIMITS TEST RESULTS 4412 SW Corbett Avenue PBS Portland,Oregon 97239 Phone:503.248.1939 PROPOSED HOTEL DEVELOPMENT PBS PROJECT NUMBER: Fax:866.727.0140 Engineering+ TIGARD,OREGON 70976.000 Environmental I TEST METHOD:ASTM D4318 60 I 50CH or OH 1 "A"LINE I x 40 w CI I Z I- 30 cn� CL or OL 0- I 201 • MH or OH I 10 CL-ML I ML or OL 0 0 10 20 30 40 50 60 70 80 90 100 110 I LIQUID LIMIT 0 a q ioN 0 O Y I a I- SAMPLE NATURAL MOISTURE PERCENT PASSING 00. KEY EXPLORATION SAMPLE DEPTH CONTENT NO.40 SIEVE LIQUID PLASTIC PLASTICITY 2 NUMBER NUMBER (FEET) (PERCENT) (PERCENT) LIMIT LIMIT INDEX '!r' • B-3 S-3 7.0 32 NA 40 23 17 1 I B-5 S-5 15.0 33 NA 48 25 23 m a "iii ye �i 0 O r m1 I §, § cd I I O w FIGURE B1 a Page 1 of 1 I 1 4412 SW Corbett Avenue CONSOLIDATION TEST RESULTS Portland,Oregon 97239 PBS Phone:503.248.1939 I Fax:866.727.0140 PROPOSED HOTEL DEVELOPMENT PBS PROJECT NUMBER: Engineering+ TIGARD,OREGON 70976.000 Environmental I 0 1 2 . I 4 1 6 1 z 8 z w U 1 cx w a z 10 1 g u) 12 \ .1 14 1 16 1 U 2 18 A w 0 20 8 0.1 1.0 10.0 100.0 111 I I PRESSURE, p(tonlft2) � ,°1_ I aci INITIAL SAMPLE INITIAL FINAL KEY EXPLORATION SAMPLE DEPTH MOISTURE DRY DENSITY SATURATION CO NUMBER NUMBER (FEET) CONTENT (PCF) (PERCENT) (PERCENT) mKi lz • B-3 S-2 5.0 33.3 86.2 100.0 d 8 o 00 a Z FIGURE B2 8 Page 1of1