Loading...
Report (113) 0 ® C\-4 4 TiRANE Submittal � -, � Akt Prepared For: Date:May 22, 2018 ProTemp Rich Wilcox RECEIVED Sales/Estimator Rich@protmp.corn JUN 19 20118 Phone #(503)233-6911 Fax#(503) 238-9767 CITY OF PGA D Engineer: iG Job Number: UI ` ` NISI N Interface Din Tai Fun Washington Square 9677 SW Washington Square Rd TIGARD, OR 97223 Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Tag Product 4 AC-1,2,3,4 4-8 Ton R410A PKGD Unitary Gas/Electric Rooftop 1 AC-5 12-1/2 Ton R410A PKGD Unitary Gas/Electric Rooftop The attached information describes the equipment we propose to fumish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed Prepared By: between submittal generation and equipment release,the product Sarah McQuistion performance and submittal data will need to be verified. It is the TraneOregon customer's responsibility to obtain such verification. 503-431-2513 Sarah.McQuistion@Trane.com OFFICE COPY J:IJOBSI124171846151Submittal 2018-05-22 Din Tai Fun.doc r , Table Of Contents Product Summary 1 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Items Al -A4) Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications 5 Unit Dimensions 7 Weight, Clearance&Rigging Diagram 14 Accessory 18 Packaged Gas/Electric Rooftop Units (Item B1) Tag Data 26 Product Data 26 Performance Data 27 Mechanical Specifications 28 Unit Dimensions 31 Weight, Clearance&Rigging Diagram 33 Accessory 35 r , Din Tai Fun Washington Square May 22,2018 Tag Data-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop(Qty: 4) Item Tag(s) Qty Description Model Number Al AC-1 1 6 Ton Nominal DX Cool +Gas Heat Pkg. YZC072F4RVA--KEB0000000 A2 AC-2 1 7-1/2 Ton Nominal DX Cool + Gas Heat YZC090F4RVA--KEB0000000 A3 AC-3 1 6 Ton Nominal DX Cool +Gas Heat Pkg. YZC072F4RVA--KEB0000000 A4 AC-4 1 4 Ton Nominal DX Cool +Gas Heat YSC048G4RLB--K0B0000001 Product Data-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop All Units DX cooling, gas heat Convertible configuration Major design sequence 460/60/3 Microprocessor controls 3ph Low Leak Econ-dry bulb 0-100%/bar rel 3p Standard panel/2 in pleated filters Mery 8 Roof curb(Fld) Item: Al,A3 Qty: 2 Tag(s): AC-1, AC-3 Ultra high efficiency 6 Ton Single compressor Modulating gas heat SSHX 3ph Item: A2 Qty: 1 Tag(s): AC-2 Ultra high efficiency 7.5 Ton Single compressor Modulating gas heat SSHX 3ph Item: A4 Qty: 1 Tag(s): AC-4 Standard efficiency 4 Ton Low gas heat 3ph Frostat 3ph Power exhaust(Fid) FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 3 of 37 Others 4 r 4 Din Tai Fun Washington Square May 22,2018 1 Performance Data-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Tags AC-1 AC-2 AC-3 AC-4 Design Airflow(cfm) 1600 2600 1950 1600 Airflow Application Downflow Downflow Downflow Downflow Cooling Entering DB (F) 79.70 80.40 81.60 75.00 Cooling Entering WB(F) 66.30 66.00 67.00 60.00 Ambient Temp(F) 95.00 95.00 95.00 95.00 Evap Coil Leaving Air Temp(DB)(F) 54.30 54.50 55.34 50.03 Evap Coil Leaving Air Temp(WB)(F) 54.20 54.42 55.24 49.91 Gross Total Capacity(MBh) 59.2 89.22 68.70 42.31 Gross Sensible Capacity(MBh) 43.9 72.04 54.33 42.17 Heating EAT(F) 37.00 31.00 30.00 70.00 Heating LAT(F) 95.80 88.90 87.90 107.80 Heating Delta T(F) 58.80 57.90 57.90 37.80 Input Heating Capacity(MBh) 150.00 200.00 150.00 80.00 Output Heating Capacity(MBh) 121.50 162.00 121.50 64.80 Output Heating Cap. w/Fan (MBh) 123.77 165.54 123.82 67.36 Design ESP(in H2O) 1.000 1.000 1.000 1.000 Indoor mtr operating power(bhp) 0.76 1.22 0.78 0.84 Indoor RPM (rpm) 1027 1202 1034 1181 Indoor Motor Power(kW) 0.57 0.91 0.58 0.63 Compressor Power(kW) 0.00 0.00 0.00 0.00 System Power(kW) 5.82 7.73 5.82 4.77 MCA(A) 22.00 23.00 22.00 11.00 MOP(A) 30.00 35.00 30.00 15.00 Evaporator face area(sq ft) 12.40 12.40 12.40 6.98 Evaporator rows(Each) 5.00 4.00 5.00 2.00 Evaporator fin spacing (Per Foot) 192 192 192 192 Evaporator face velocity(ft/min) 155 210 157 229 Fan motor heat(MBh) 2.11 4.12 2.16 2.31 Refrig charge(HFC-410A)-ckt 1 (Ib) 8.3 8.7 8.3 3.5 SEER/IEER @ AHRI (MBH/kW ) -/23.20 -/22.40 -/23.20 13.5/- EER @ AHRI Conditions (MBH/kW) 12.6 12.8 12.6 12.0 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 4 of 37 Others IR Din Tai Fun Washington Square May 22,2018 Mechanical Specifications-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A4 Qty: 4 Tag(s): AC-1, AC-2, AC-3,AC-4 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Cooling performance shall be rated in accordance with ARI testing procedures.All units shall be factory assembled, internally wired,fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 8117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation.All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Two-Inch Pleated Filters 2"pleated media filters shall be available on all models. Compressors All units shall have direct-drive, hermetic,scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor)are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units(standard and high efficiency 3-phase)have multispeed, direct drive motors. All 6 to 8%ton units(standard efficiency)shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected.All 10 tons, 6 ton (074), 7%to 8%(high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig.The assembled unit shall be leak tested to 465 psig. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 5 of 37 Others Din Tai Fun Washington Square May 22,2018 The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device.A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions.The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort.A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout.An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI)system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane(field-installed kit) and also comply with the California requirement for low NOx emissions(Gas/Electric Only). Accessory- Powered Exhaust(where noted in product data) The powered exhaust shall provide exhaust of return air,when using an economizer, to maintain better building pressurization. Accessory-Roof Curb The roof curb shall be designed to mate with the unit's downflow supply and return and provide support and a water tight installation when installed properly. The roof curb design shall allow field fabricated rectangular supply/return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 6 of 37 Others s Din Tai Fun Washington Square May 22,2018 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 3 Tag(s): AC-1, AC-2,AC-3 TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) 1N ` 3/4"-14 NPT DIA.HOLE /i�I Z �a�{a ICONDENSER COIL 41/4 %„,k� II I 27 5/8" \ UNIT CONTROL WIRE 7/8"DIA.HOLE •IPSERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE 477/8 l''-,.. 1 '�� UNIT POWER WIRE 1/2"NPT GAS CONNECTION �� (80MBH&120MBH) 3/4"NPT GAS CONNECTION (150MBH,200MBH&250MBH) CONTROL AND COMPRESSOR ACCESS PANEL PACKAGED GAS/ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATE 4 1/8" 1..,___27 5/8"--.- NOTES: 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. I--- --1 r----� 111 'Ii33 32 1/8" SUPPLY RETURN L-- — —�-- Imimimimma 4 - 17 1/2"�9 7/8" 17 1/2" - o-3 5/8" PLAN VIEW UNIT DIMENSION DRAWING 7 RETURN III 46 7/8" HORIZONTAL 23 7/8" SUPPLY 32 1/4 AIR FLOW 24 1/2„9 5/8" INN • ' ' � J•��r� 5 5/8" •• / , E• NO 4 3/4" i �R� ��� - 19 1/4" 4 9 3/8" - 16 3/4" - 3 7/8" 4 1/4" - I� CONDENSATE I 88 5/8" 5 5/8" 7 5/8" - - PACKAGED GAS/ELECTRICAL 531/4" DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 7 of 37 Others A , • Din Tai Fun Washington Square May 22,2018 t Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 3 Tag(s): AC-1, AC-2,AC-3 ,, ,, ,,,,,,,,,,,,,T,.............._. . ,,,,,, .-.,--,*,,,,,„ , RETURN 3/4"-14 DIA HOLE 8 .°./..1°// CONDENSATE DRAIN q\ O I 27 5/8" 4 3/4" ISOMETRIC-PACKAGED COOLING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Others Page 8 of 37 • Din Tai Fun Washington Square May 22,2018 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al, A3 Qty: 2 Tag(s): AC-1, AC-3 ELECTRICAL/GENERAL DATA GENERAL (2)141(8) HEATING PERFORMANCE Model: YZ*0072F4 Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Unit Primary Voltage: 460 MFS: N/A Heating Model: 'Modulating Unit Secondary Voltage -- MCB: N/A Heating Input(BTU): 150000 Unit Hertz: 60 Heating Output(BTU): 121000 Unit Phase: 3 No.Burners: 3 No.Stages 2.5:1 Modulating EER/SEER 12.6/23.2 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA: 22.0 MCA: N/A Natural Gas(Min/Max): '4.5/14.0 MFS: 30.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 30.0 MCB: N/A Gas Pipe Connection Size: 1/2"/1/2"/3/4" 1 INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: '1 Number: N/A Number: N/A Horsepower: 2.75 Horsepower: N/A Horsepower: N/A Motor Speed(RPM): DirectNariable Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 3.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '1 Number 1 Horsepower: Variable Speed Horsepower 0.75 Phase: 3 Motor Speed(RPM): 1200 Rated Load Amps: 12.24 Phase: 1 Locked Rotor Amps: Full Load Amps: 3.1 VFD Input Amps: Locked Rotor Amps: - POWER EXHAUST ACCESSORY 13) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410A Phase: Type: Throwaway Horsepower: Furnished: Yes Factory Charge Motor Speed(RPM): Number 4 Circuit#1 8.3 lb Full Load Amps: Recommended 20"x25"x2" Circuit#2 - Locked Rotor Amps: NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated atAHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 9 of 37 Others • Din Tai Fun Washington Square May 22,2018 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 1 Tag(s):AC-2 ELECTRICAL/GENERAL DATA GENERAL (2)14)/6 HEATING PERFORMANCE Model: YZ*090F4 Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: . N/A Unit Primary Voltage: 460 MFS: N/A Heating Model: Modulating Unit Secondary Voltage -- MCB: N/A Heating Input(BTU): 200000 Unit Hertz: 80 Heating Output(BTU): 162000 Unit Phase: 3 No.Burners: 5 EER/SEER 12.8/22.4 No.Stages 2.5:1 Modulating Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 23.0 MCA: N/A Natural Gas(Min/Max): '4.5/14.0 MFS: 35.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 35.0 MCB: N/A Gas Pipe Connection Size: 1/2"/3/4"/3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: '1 Number: N/A Horsepower: 2.75 Number: N/A Horsepower: N/A Horsepower N/A Motor Speed(RPM): DirectNariable Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 3.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '1 Number. 1 Horsepower: Variable Speed Horsepower: 0.75 Phase: 3 Motor Speed(RPM): 1200 Rated Load Amps: 12.85 Phase: 1 Locked Rotor Amps: Full Load Amps: 3.1 VFD Input Amps: Locked Rotor Amps: POWER EXHAUST ACCESSORY 13) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Phase: Type R-410A Horsepower. Type: Throwaway Furnished: Yes Factory Charge Motor Speed(RPM): Number 48.7 lb Full Load Amps: Circuit#1 Recommended 20"x25"x2" Circuit#2 Locked Rotor Amps: NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated atAHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 10 of 37 Others , • Din Tai Fun Washington Square May 22,2018 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s): AC-4 TOP PANEL qhIlliii EVAPORATOR CONDENSER FAN SECTION ACCESS PANEL 1``� 000000000 Ifr, 00000��lJ CONDENSATE 4-1NPT DIA.HOLE(ALT) I 4rla ii 'Iliktillil , CONDENSER COIL I 4 1/4" 239/16"421/4 �� UNIT CONTROL WIRE 7/8"DIA.HOLE 2SERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE UNIT POWER WIRE CONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE CONDENSATE 1/2"NPT GAS CONNECTION - 231/2" NOTES: ;�4 3/16" 1.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. I 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION ill" \`ttgj1 RETURN 24" SUPPLY I 18" - 15 1/2" - 91/4" 14" - 35/8" PLAN VIEW UNIT DIMENSION DRAWING 10 i RETURN 40 7/8" [ 231/4" HORIZONTAL SUPPLY 143/4" AIRFLOW 201/4" 1 !1i1II 4 3/4" 9 5/8" -171/4" 18 7/8" -13 1/4" - 3 3/16" I' - 69 7/8" 5 9/16" CONDENSATE 7 5/8" 441/4" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 11 of 37 Others Din Tai Fun Washington Square May 22,2018 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s):AC-4 (.... •••••/../ SUPPLY lig RETURN 3/4"-14 NPT DRAIN CONNECTION 23 9/16" - 4 1/4" ISOMETRIC-PACKAGED COOLING FLD=Furnished by Trane U.S Inc./Installed by Equipment Submittal Page 12 of 37 Others 4 , Din Tai Fun Washington Square May 22,2018 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s): AC-4 ELECTRICAL/GENERAL DATA 'GENERAL (21(4)/6) HEATING PERFORMANCE Model: YSC048G Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Unit Primary Voltage: 460 MFS: N/A Heating Model: Low Unit Secondary Voltage -- MCB: N/A Heating Input(BTU): 80,000/56,000 Unit Hertz: B0 Heating Output(BTU): 64,800/45,360 Unit Phase: 3 No.Burners: 2 EER/SEER No.Stages 2 12.0/14.0 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 11.0 MCA: N/A Natural Gas(Min/Mix): 4.5/14.0 MFS: 15.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 15.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: 1 Number: N/A Number: N/A Horsepower: 1.0 Horsepower: N/A Horsepower N/A Motor Speed(RPM): -- Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 1 Phase N/A Phase N/A Full Load Amps: 2.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: -- Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number 1 Horsepower: 3.6 Horsepower: 0.33 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 6.2 Phase: 1 Locked Rotor Amps: 41.0 Full Load Amps: 0.7 . Locked Rotor Amps: 2.3 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: 1 Type: Throwaway Horsepower: 0.33 Furnished: Yes Factory Charge Motor Speed(RPM): 1075 Number 2 Circuit#1 31/2" Full Load Amps: 1.1 Recommended 20"x35"x2" Circuit#2 N/A Locked Rotor Amps: 2.0 NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated atAHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 13 of 37 Others Din Tai Fun Washington Square May 22,2018 Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al, A3 Qty: 2 Tag(s): AC-1, AC-3 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 193.0 lb MOTORIZED OUTSIDE AIR DAMPER 0 MANUAL OUTSIDE AIR DAMPER I/j BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR t rc,u 1X1tt POWER EXHAUST ,............. � THROUGHT THE BASE ELECTRICAUGAS(FIOPS) ,� UNIT MOUNTED CIRCUIT BREAKER(Flops) �� UNIT MOUNTED DISCONNECT(Flops) POWERED CONVENIENCE OUTLET(FIOPS) (S ,•) HINGED DOORS(FIOPS) C HAIL GUARD SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB 78.0 lb BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY I SHIPPING NET A® 321.0 lb © 262.0 lb (E)LENGHT (F)WIDTH 966.0 lb 868.0 lb OB 184.0 lb OD 101.0 lb 64" 22" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. fr........4.4%.%44%,' 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/_10%of the nameplate weight.. 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. 10 (ri I, ...77' AN 40.0 E Sli..4 ° �, F PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 14 of 37 Others Din Tai Fun Washington Square May 22,2018 Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 1 Tag(s):AC-2 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 93.0 lb MOTORIZED OUTSIDE AIR DAMPER O MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF 1 OVERSIZED MOTOR BELT DRIVE MOTOR tiff"rr. VI POWER EXHAUST ilisimianimim ViMlir/��JJI THROUGHT THE BASE ELECTRICAUGAS(FIOPS) iimeasrmismis 0. UNIT MOUNTED CIRCUIT BREAKER(FIOPS) �� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) /!� HINGED DOORS(FIOPS) O HAIL GUARD SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 0 248.0 lb © 261.0 lb (E)LENGHT (F)WIDTH 1007.0 lb 909.0 lb0 210.0 lb O 190.0 lb 51" 26" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide.• 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/_10%of the nameplate weight.. 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field `\ installed accessories. 111111111111111111 N. III)-''---/-- ------7.:T: ,\''''l\\IN\-N. ® a � i E 111114 , � � PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 15 of 37 Others • Din Tai Fun Washington Square May 22,2018 Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s):AC-4 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 68.0 lb MOTORIZED OUTSIDE AIR DAMPER Q\ 0 MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR 1111111■11BELT DRIVE MOTOR �VS,WP �tf 1111 POWER EXHAUST 40.0 lb IMiliniiiii II))) THROUGHT THE BASE ELECTRICAUGAS(FIOPS) iimmana �� UNIT MOUNTED CIRCUIT BREAKER(FIOPS) �� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) (22, -,),4k.,,, HINGED DOORS(FIOPS) 0 O HAIL GUARD SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET O 205.0 lb © 46.0 lb (E)LENGHT (F)WIDTH 598.0 lb 492.0 lb ( 183.0 lb O 58.0 lb 33" 9" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. / 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation // of unit. / 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/-10%of the nameplate weight.. / • 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field \\ installed accessories. i E , ®.iiiii �,iIr /0 F i a 000/1111 o PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 16 of 37 Others Din Tai Fun Washington Square May 22,2018 • Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s): AC-4 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" 002) ' 1;70'. IN‘. oil RETURN oi///0 L� \ DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING I ' I UNIT OUTLINE I 37" 44 1/2" I I I ___i_ 1 40" -i 68 3/16" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 17 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 3 Tag(s): AC-1,AC-2,AC-3 NOTES: RETURN OPENING 1.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION SUPPLY OPENING 1 11/16" - 18 7/16" - 8 5/8" L,-18 7/16" - 1 11/16" 34 3/8" 1 34 3/8"11 46 7/16" I I - 111 2„ 83 15/16" 49 13/16" 14" 14" - 84 1/2" - 50 7/16" ROOF TOP CURB(BAYCURB043) ACCESSORY FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 18 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 3 Tag(s): AC-1, AC-2,AC-3 Downflow Duct Connections-Field Fabricated All Flanges- 1 1/4" 17 3/4" 33 3/4" 41116111' 17 3/4" kill 33 3/4 I I1/6No I I I I I 4 0111 I 0 ofiVO ACCESSORY-DUCT CONNECTIONS FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 19 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 3 Tag(s): AC-1,AC-2, AC-3 1 Illahhh. `y /I ECONOMIZER HOOD ia / BAROMETRIC RELIEF HOOD ECONOMIZER HOOD 0 11136 1/2" „,„' 00 III 00 , 11 1/2" - 28" - LOW LEAK ECONOMIZER HOOD ACCESSORY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 20 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 1 Tag(s):AC-2 1 t:52 41tttl '4\ 4 1 00 I yIL 0 ECONOMIZER HOOD r. .—. ."– ECONOMIZER HOOD o I♦ 00 MM1 00 sa,. 16 3/4" ACCESSORY-ECONOMIZER HOOD FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 21 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s): AC-4 NOTES: RETURN OPENING 1.VERIFY WEIGHT CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION SUPPLY OPENING 1 11/16" 14 9/16" 8 3/8" 16 11/16"-- -20-3/8" 1 11/16" 1713/16" 25 3/16" 37 7/16" • 2.. 65 1/8" - 40 13/16" 1-ti _n 14" JL 41 7/16" 65 3/4" ROOF TOP CURB(BAYCURB042) ACCESSORY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 22 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s):AC-4 Downflow Duct Connections-Field Fabricated All Flanges- 1 1/4" 24 .44•6._.,,„,- 14 1116" �16 3/16" %1111 1/16 1 I 17 " I 11 )10A °/11°./° DUCT CONNECTIONS ACCESSORY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 23 of 37 Others Din Tai Fun Washington Square May 22,2018 Accessory-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s): AC-4 C-----.) r .1.,,iiii1114114144iiiiiil• II 40 1 0 r 11111111111114111111114111111 • /I 11111111111‘. 1111 ECONOMIZER HOOD 00 BAROMETRIC RELIEF HOOD ECONOMIZER HOOD C r''' .. .' " 29" 4 ■ 0 0 ii. 0 0 6.. L3/4" 19" - LOW LEAK ECONOMIZER HOOD ACCESSORY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 24 of 37 Others WMay 22,2018 Accessory,DinTaiFun W. 3-10 ashington Ton R410SquareA PKGD Unitary Gas/Electric Rooftop Item: A4 Qty: 1 Tag(s):AC-4 ------) i 6 \�i ECONOMIZER HOOD POWER EXHAUST-/./>''''''' POWER EXHAUST Q 6 3/16" 16 1/2"-- POWER /2"-- POWER EXHAUST AND HOOD ACCESSORY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 25 of 37 Others / Din Tai Fun Washington Square quare May 22,2018 Tag Data- Packa ed Gas/Electric Rooftop Units (Qty: 1) Item Tag(s) Qty Description Model Number B1 AC-5 1 12-1/2 Ton Nominal DX Cool + Gas Heat YSD150G4RH Product Data-Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): AC-5 Gas/Electric Downflow 460/60/3 Reliatel Gas Heat-High Low Leak Economizer, Dry Bulb w/Barometric Relief Two speed fan oversized motor Standard panels/Pleated Filters Mery 8 Roof curb (Fld) Power exhaust(Fld) FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 26 of 37 Others Din Tai Fun Washington Square May 22,2018 Performance Data- Packaged Gas/Electric Rooftop Units Tags AC-5 Design Airflow(cfm) 5000 Ambient Temp(F) 95.00 Cooling Coil Leaving DB (F) 52.70 Cooling Coil Leaving WB(F) 52.40 Gross Total Capacity (MBh) 134.93 Gross Sensible Capacity(MBh) 120.25 Gross Latent Capacity(MBh) 14.68 Heating EAT (F) 70.00 Heating LAT(F) 106.87 Heating Temp Rise(F) 36.87 Output Htg Capacity(MBh) 200.00 Output Htg Capacity w/Fan (MBh) 212.63 Design ESP(in H2O) 1.000 Indoor Mtr. Operating Power(bhp) 4.01 Indoor RPM (rpm) 993 Indoor Motor Power(kW) 2.99 Outdoor Motor Power(kW) 0.93 Compressor Power(kW) 10.26 System Power(kW) 14.18 MCA(A) 32.00 MOP (A) 40.00 Evaporator Face Area(sq ft) 17.30 Evaporator Face Velocity(ft/min) 289 Fan Motor Heat(MBh) 12.63 Evap Coil Leav Air Temp(DB)(F) 52.73 Evap Coil Leav Air Temp(WB)(F) 52.37 Exhaust fan power(kW) 0.56 Refrig charge(HFC-410A)-ckt 1 (Ib) 8.1 Refrig charge(HFC-410A)-ckt 2(Ib) 5.1 IEER @ AHRI Conditions (MBH/kW) 13.50 EER @ AHRI Conditions(MBH/kW) 11.0 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 27 of 37 Others Din Tai Fun Washington Square May 22,2018 Mechanical Specifications-Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s):AC-5 General- Downflow The units shall be dedicated downflow airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with ARI testing procedures.All units shall be factory assembled, internally wired,fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled,classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. Packaged Rooftop units cooling, heating capacities, and efficiencies are AHRI certified within scope of AHRI Standard 340/360 (I-P) and ANSIZ21.47 and 10 CFR Part 431 pertaining to Commercial Warm Air Furnaces(gas heating units). Casing - Downflow Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal,service panels shall have lifting handles and no more than three screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced, fire-resistant, permanent,odorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units Compressors All units shall have direct-drive, hermetic,scroll type compressors with centrifugal type oil pumps.Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors.All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Dual compressors are available on all standard efficiency models and 12.5 to 20 tons high efficiency models and allow for efficient cooling utilizing 3 stages of compressor operation(high efficiency models only). 25 tons high efficiency units have 3 compressors for up to 4 stages of compressor operation. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. Refrigerant Circuits Each refrigerant circuit shall have service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Evaporator Coils(only on T/YS*150, 180, 210, 240, 300G models)- Microchannel evaporator coils will be burst tested by the manufacturer. Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Coils shall be leak tested to ensure the pressure integrity. The evaporator coil shall be leak tested to 225 psig and pressure tested to 450 psig. Condenser Coils(available on T/Y**150, 180,210,240,300G models)-Microchannel condenser coils shall be standard on all units. Coils shall be leak tested to ensure the pressure integrity. The condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 28 of 37 Others , Din Tai Fun Washington Square May 22,2018 • forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas shall also comply with California requirements for low NOx emissions. Condenser Coil The microchannel type condenser coil is standard for the standard efficiency models. Due to flat streamlined tubes with small ports, and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume,which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight.All-aluminum construction improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s)shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Multi-Speed Indoor Fan System Multi-speed indoor fan system is designed for use in applications for meeting the minimum requirement of CA Title 24. This system incorporates a multi-speed fan control to change the speed of the fan to 67% of full airflow based off of compressor stages. Variable Frequency Drive Variable Frequency Drives are factory installed and tested to provide supply fan motor speed Modulation. VFDs on the supply fan,as compared to inlet guide vanes or discharge dampers,are quieter,more efficient,and are eligible for utility rebates. All VFDs are designed to allow bypass if required. Bypass control will simply provide full nominal airflow in the event of drive failure. Bypass mode is indicated in the unit wiring manual. Modulating gas heat models with SZVAV allow tighter space temperature control with less temperature swing. Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort.A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Oversized Motors Oversized motors shall be available for high static applications. Low Leak Economizer This accessory meets low leak requirements for ASHRAE90.1, IECC, and Title 24 standards; Allows 100 percent outdoor air supply from 0-100 percent modulating dampers; Comes standard with Barometric Relief; can be paired with Powered exhaust for additional building evacuation; Can paired with Fault Detection (FDD)to meet current mandatory Title 24 requirements. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 29 of 37 Others • . Din Tai Fun Washington Square May 22,2018 Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit, the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature on the discharge line cools down,the bi-metal disc closes the contactor circuit, providing power to the compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage. Two-Inch Pleated Filters(MERV 8) Two inch pleated media filters shall be available on all models. Accessory- Powered Exhaust The powered exhaust shall provide exhaust of return air, when using an economizer, to maintain better building pressurization. Accessory- Roof Curb- Downflow The roof curb shall be designed to mate with the downflow unit and provide support and a water tight installation when installed properly. The roof curb design shall allow field-fabricated rectangular supply/return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 30 of 37 Others Din Tai Fun Washington Square May 22,2018 Unit Dimensions-Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): AC-5 NOTES: 1.GAS CONNECTION PIPE SIZE 1/2" 2.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS.(SELECTED OPTION:SEE ACCESSORY SHEET) 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION �1 (03_;_::3* 52[i1'" L 1, OS** ` 1 '(' A'.... ---...- '..."\ 4%'---- ir'''''''' DOWNFLOW CONDENSATE 0 DRAIN CONN 1"NPT 25 5/8" 29 5/16" 42 3/4" S 410., IIIIIPIII' 1111141411116.,-411 C. 1 " 7/8"DIA.HOLE 11'. 571/8 1011//1616"/ (UNIT CONTROL WIRE) ,,,,, \ 73 3/ d SERVICE GAUGE GAS CONNECTION(SEE NOTE 1) PORT ACCESS 211/16" 13 9/16" 106 11/16" 44 9/16" PACKAGED GAS/ELECTRIC-DOWNFLOW 70 13/16" 2"DIA.HOLE ISOMETRIC DRAWING (UNIT POWER WIRE) 018 11/16"=-=1-22 1/2"-o-26 7/16"--- 41/4"� �- 41/4"J r Ti ( froixttt% „nevi] 54 11/16" SUPPLY 62 7/16" RETURN #11k L_, __J % •IN 1 PACKAGED GAS/ELECTRIC-DOWNFLOW PLAN VIEW DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 31 of 37 Others , Din Tai Fun Washington Square May 22,2018 Unit Dimensions-Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): AC-5 ELECTRICAL/ GENERAL DATA GENERAL PERFORMANCE Standard Motor (1)13) Model(Ton): YSD150G(12.5) Minimum Circuit Ampacity: 29.0 Unit Operating Voltage Range: 414-506 Maximum Fuse Size: 40.0 Unit Primary Voltage: 460 Maximum(HACR)Circuit Breaker: 40.0 Unit Secondary Voltage: - Unit Hertz: 60 Oversized Motor (11(4) Field Installed Oversized Motor (1)(4) Unit Phase: 3 MCA: 32.0 MCA: N/A MFS: 40.0 MFS: N/A EER:(5) 11.0 MCB(HACR): 40.0 MCB(HACR): N/A GAS HEATING COMPRESSOR Heating Models: High Circuit(s) Heating and 1 Stage Input(Btu/h) 250000/175000 Number: 2 Heating and 1 Stage Output(Btu/h): 200000/140000 Min./Max.Gas Input- Horsepower: 3.9/3.5 Phase: 3 Pressure Natural or LP: 2.5/14.0 Rated Load Amps: 122/62 Gas Connection Pipe Size: 1/2" Locked Rotor Amps: 100.0/41.0 INDOOR MOTOR Oversized Motor (4) Field Installed Oversized Motor (41 Number: 131 1 Number: 1 Number: N/A Horsepower: 3.00 Horsepower: 5.00 Hp: N/A Motor Speed(RPM): 1,740 Motor Speed(RPM): 3,450 Motor Speed(RPM): N/A Phase: 3 Phase: 3 Phase: N/A Full Load Amps: 4.8 Full Load Amps: 7.6 FLA: N/A Locked Rotor Amps: 40.5 Locked Rotor Amps: 54.9 LRA: N/A OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (Field Installed Power Exhaust) MOTOR Number 2 Horsepower: 0.75 (Gas-Fired Heating only) Horsepower: 0.50 Motor Speed(RPM): 1,040 Horsepower: 0.05 Phase: speed(RPM): 1,100 Phase: 1 Motor Speed(RPM): 3,500/2,800 Phase: 3 Full Load Amps: 3.2 Full Load Amps: 1.35 Locked Rotor Amps: 8.4 Phase: 1 Full Load Amps: 10.5 Locked Rotor Amps: 4.82 Locked Rotor Amps: 0.78 FILTER REFRIGERANT (2) • Circuit#1/2 Type: Throwaway Type: R410 Furnished: Yes Factory Charge Number: 2/4 Circuit#1/2: 8.1 lb/5.1 lb Recommended Size: 20"x20"x2"/20"x25"x2" NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value includes oversized motor. 4.Value does not include Power Exhaust Accessory. 5.EER is rated atAHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 32 of 37 Others , Din Tai Fun Washington Square May 22,2018 Weight, Clearance &Rigging Diagram - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): AC-5 CLEARANCE11111‘ M 68" (1727.2M) CLEARANCE 36" CLEARANCE FROM (914.4MM) TOP OF UNIT 72" (1828.8MM) CLEARANCE 60" ' (1524MM) CLEAR48" NCE (1219.2AM) 0 DOWNFLOW-PACKAGED GAS/ELECTRIC CLEARANCE UNIT OUTLINE \ \ � ROOF OPENING \ r 73 1/2" \ / 62 1/2" DOWNFLOW-PACKAGED GAS/ELECTRIC ROOF OPENING CLEARANCE FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 33 of 37 Others S • Din Tai Fun Washington Square May 22,2018 Weight, Clearance& Rigging Diagram - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s):AC-5 � 20 Base Unit and Corner Weights only " Base unit weights Corner Weights Center of Gravity .----W SHIPPING NET OA © © Op E F ����f�r�:`\\`� 1820.0 lb 1448.0 lb 537.0 lb 381.0 lb 225.0 lb 306.0 lb 45" 26 \`i1/4 �/4/ 1.All weights are approximate. \ ''/ 2.The actual weight are listed on the unit nameplate. 3.Refer to unit nameplate and installation guide for weights before scheduling transportation A015:4 � and installation of unit. QP �� 4.The weight shown represents the typical unit operating weight for the configuration �����r��`��l\1 selected.Estimated at+/-10 %of the nameplate weight.. 1'1111����`•i/1��1j 5.Verify weight,connection,and all dimension with installer documents before installation. \\\`` 6.Corner weights are given for information only. �� 7.Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. \O \_ Installed Options Net Weight Data V W v r Accessory Weight CORNER WEIGHT JJ Economizer,Manual and Motorized Outside Air Damper 180.0 lb Power Exhaust 95.0 lb Roof Curb 205.0 lb Oversized Motor 5.0 lb Hail Guard Hinged Access Doors Power Conv.Outlet Through the Base Electrical Circuit Breaker Disconnect Smoke Detector Novar Zone Sensor 1 High/Low Static Drive Kit frifr LP Gas Conversion Stainless Steel Heat Exchanger Stainless Steel Drain Pan VFD 32.0 lb High Efficiency Motor 1.Weights for options are approximate. 2.Weights for options that are not list refer to Installation guide. d a N\ ,---->// ..m 11 o 0 . c ri C : . . PACKAGED GAS/ELECTRIC RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 34 of 37 Others r Din Tai Fun Washington Square May 22,2018 Accessory- Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s):AC-5 END PANEL a ACCESS PANEL ECONOMIZER HOOD 64" 161/4" ECONOMIZER HOOD PLAN VIEW DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 35 of 37 Others f . Din Tai Fun Washington Square May 22,2018 Accessory- Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): AC-5 END OF PANEL UNIT T ECONOMIZER HOOD 0 tJ"' ; POWER EXHAUST1%7P ioi POWER EXHAUST ACCESSORY DRAWING 36" - FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 36 of 37 Others f Din Tai Fun Washington Square May 22,2018 Accessory- Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): AC-5 101 7/8" _ 113/16" - - 207/8" 171/8" 281/2" 1 13/16" 1" - 1" 1" ' 1 63" 66 5/8" 55 1/2" RETURN SUPPLY 1 1 N ACCESSORY-ROOF CURB 1- 17 3/4" 59 7/16" 1" 1 1/16" RETURN 2611/16" I SUPPLY 1" ••••10 I I 52 1/2" 7 7/16" /�'® il 14" i 01111111 • 102 1/4" 67" 2" ACCESSORY-DOWNFLOW DUCT CONNECTIONS FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 37 of 37 Others 1 r • _ - 100 tW dMOnR See 4t ,Suite 1600 to 1NTERFAC :. 503.382.2266ENGINEERING a: 503.382.2262 www.interfaceengineering.com Submittal Review P oiet1 Number 2018-0046 ftztt:€- May 30,2018 t°a ujee.t Name Din Tai Fung at Washington Square Carter Schaffran Phone- 360-823-4227 Western Construction €'#: 230000-01 Revice.ed By John Kotas,PE Interface Engineering,Inc. Applies To Mcchun ica Sys(en t 2,-3, Where a submitted manufacturer differs from the basis of design manufacturer,the Contractor must obtain approval through the Substitution Request process as outlined in the Contract Documents before submitting alternate manufacturer. After receiving approval,additional coordination documents may be required. Reference the Submittals Requirements for specific details. Incomplete or piecemeal submissions will be returned to the Contractor without review. The Contractor may incur additional charges if submittals are not in compliance with the Contract Documents. Reference Submittal Requirements in Division 01,General Requirements,as well as the Submittals Requirements in Divisions 21 through 28,Basic Requirements. The following items were reviewed for conformance with the requirements of the Contract Documents. tis)Ositi€e item t °.=inti€ ' t F 1 2 DIVISION 23 1. (AC-1 through AC-4)3-10 Ton R410A PKGD Unitary Gas/Electric RTU X 2. (AC-5) 12-1/2 Ton Nominal DX Cool&Gas Heat RTU X Disposition Code N No exception taken. M Make corrections noted.Resubmittal not required if installation complies with notes. R Revise and resubmit. I Manufacturer not approved. Resubmit. 2 Does not meet requirements of Contract Documents. Returned without review. See comments above and Submittal Requirements in the Specifications. Resubmit. F Forward specified item above. I/Interface Engineering,Inc.