Loading...
Plans (24) M EC2016 - 00436 ," L RElflS10:S :,..1•1.,,,....B,.._;Y \\s„:,.., REEF:111E15 \ \3 . 1 . \ -- 2. ' 1:-‘.6,.:.,,, ,,. -:--4a.-- - vihi , , \•• , ..., . :.„:. • _ -- 1 _ , -141/---- 11(-- ----- . .._.. ... ........______ _ .. , .---- , / 1 , cm qvTIGARD 1--- -1-- -,, -• -...-.-../ . _____ ____. _ •., . --r --t ___ _ ' IL ---, Fl P'60% t4te-Tel2-Xlio; ' ' DU ILDINGDIVISIOtk ___ _ ,____ . L ..- . , 1 _ ........._._ TYP I HOOD SYSTEM • • . ." -itit.„...... .146.11-1, .:71, 464.46e°14T\41°5911 r--IIIII l' , 1 i .• ... ___. _.....1. ...---- -1-7 -1--7 r sV 3I l' , HOOD • II 1 - 1 - / ' • 1. THIS SYSTEM SHALL CONFIRM TO CURRENT NFPA#96 AND -. .... . ., , , • • < 1\ I > / G . _ , , - 2014 OREGON MECHANICAL SPECIALTY CODE.COMMERCIAL KITCHEN HOOD SYSTEMS OMSC 506 507 AND 508 EXCEPTIONS -- :4 A-11;1119-- --------7--:::;f:- .-4X/1(4-__- . __ -..vr- g ---- -.. 1. _. upp0 .-r,.„..... ... _ _ _ ___ ---/ , . • 1 I.:. . , , t 4%,..c.„1/1 ....1,_ ,,---,_:,.,,,t_,, ,:li..n. ' , 1 1- i -- ' ------- ----;--- i • FACTORY BUILT COMMERCIAL EXHAUST HOODS TESTED IN ____ - \ -- - 1 . it 1 14 ; i . f; ___ , _. ,I, /.\\/, \,--------i Ltli ACCORDANCE WITH UL 710.LISTED,LABELED AND INSTALLED .___ .... , „ 1 , . 1 -‘, IN ACCORDANCE WITH OMSC 304.1 , . . ... 1 , , , , , • ; 4 4 • _ -.I ,1 ., ' / 1':7- -111-1" :,.*::•-'.;!.:'-'114:12.P4''''''4'i ' ' 1 I 1 2. EXTERNAL HOOD JOINTS SEAMS AND PENETRATIONS TO BE , , • ' 1 / ' L 1. LIQUID TIGHT WELD.HOOD CONSTRUCTED OF 18 GA. STEEL OR . ' , t . ‘1 ..„._ 5 ,, , , , . , • 20 GA.STAINLESS STEEL MIN. r - • \ / - . . . . I I \.... : ft ----_-_-:._______. VI .-- 4 • . . _ ' _ 12 ' 1 3. UL LISTED GREASE FILTERS DESIGNED FOR SPECIFIC PURPOSE , __} i ' _ ,L.1,1 t`l ---_i tr READILY REMOVABLE. FILTERS TO BE INSTALLED AT AN ANGLE i ----- . .. ,• .7'' 14-4XAk ../ 4Krr-t7 iiri _ ..._ i NOT LESS THEN 45 DEGREES WITH DRIP TRAY AT LOWER EDGE. . i 1 !W 7 .-,„::,,_ ! .„.... „it iti •._ , ,- • ' --- -,..:- . - . 4. CANOPY TYP I HOODS SHALL OVER HANG COOKING EQUIPMENT ,.....1 i _ „ ._ A MIN. OF 6" AT EACH SIDE AND 12" AT FRONT OF COOK SURFACE - 1 I. i I ,1 - ._ 3 Ak 4xj41_i__ vid.:, ..1 1 • - 4$0itt-f I - i i , V • . • _ _•__ _ __ ____ _ 5. HOOD SHALL HAVE A MINIMUM OF 18"CLEARANCE FROM ' II ' '1 Z- I .."-' - I is i (0 COMBUSTIBLES CLEARANCE MAY BE REDUCED TO 3"PROVIDED ., . , t.....,..1 _ 1 1 MATERIAL IS PROTECTED WITH MATERIAL SPECIFIED FOR 1 HOUR , , ,,,. , , ._ _ , FIRE RESISTIVE CONSTRUCTION.HOODS LESS THAN 12"FROM 1 -7- ,. : 1 l Ill g t, ......... - .- --....., -.. CEILING OR WALL MUST BE FLASHED SOLIDLY. I 1 ._.....,....A ' . 6. TYP I HOODS SHALL BE SECURED IN PLACE BY NON COMBUSTIBLE --"Lr 7 ;Zr. la K - - _ ' i , ' ; ' 1,16 _ 1 .: - , ,,,, , . I i I -,\ /' 1 \ _ ..,-- mg,, -I -11 -- ,- SUPPORTS. FOR APPLIED LOAD OF HOOD,UNSUPPORTED DUCT, mee.t.weempera........ SI II ' I. \ 1 ( 1- 1 I =ilikk, WORK AND POSSIBLE PERSONNEL WORKING IN OR ON HOOD. 1 - , , .e. /\ , --- sMirAl • A ... ..,.,_ i I ' Z : ' i MY I -, 't; 1 \ L ---7 ---41'. . , i . / IV \ I .1--.-1 ' ' ______.. 7. PERFORMANCE TEST SHALL BE CONDUCTED UPON COMPLETION. VERIFY RATE OF EXHAUST AIRFLOW PER OMSC 507.13 ' ' ' - ' • • ,, . • . ., .. 1 r '', , Trot, a,-_-17... . . re I 61, _.- .• I _3.y: - 1 . \---- -- / 1qms,-012 rtviw, ___ ..- , /4,1 ' - I A V-- 07.....7..: . I ' . t k'i la 6141, - e. • EXHAUST DUCT __ ________ - ' e)qt-69 FP-e- 7 ' , __ ; .- ;-.14,5-7- - • - 1 . '-'7.---...-- .........*:;."" '.:* .V ___,LI ' - ________ 1. SHALL BE CONsTRUCTED OF 16 GA.GALV. STEEL OR 18 GA. STAINLESS STEEL AND EXTERNALLY WELDED LIQUID TIGHT I EXHAUST FAN 1 1. FAN SHALL BE LISTED AND LABELED PER UL 762 UP DISCHARGED _ . . _ -;-, 1- -4 - , PER. GMSC 506 !I RATED FOR GREASE LADEN AIR. --- ----r , ' - 1 iiiiii .0 • , ----- 2. DUCT CLEARANCE TO BE NOT LESS THEN 18"FROM COMBUSTIBLE 2. AIR DISCHARGE TO BE MINIMUM OR 40" ABOVE ROOF SURFACE \---- OF: -1 . CONSTRUCTION OR 3" FROM GYPSUM WALLBOARD ATTACHED ,;:l CITY OF TIG . 7: • --NI - WEATHERPROOF TO NONCOMBUSTIBLE STRUCTURE, ,i 3. FAN SHALL BE HINGE MOUNTED WITH FLEXIBLE ELECTRICAL • 1! CABLE, FOR CLEANING ACCESS. REVIEWED FOR CODE COMPLIANCE - -- - - 3. DUCT SHALL SLOPE NOT LESS THEN *" VERTICAL IN 12" I APProved: i 1--) 1 HORIZONTAL TOWARD HOOD. 4'; 4. OUTLET POINT OF FAN SHALL TERMINATE MINIMUM OF•10' OTC: , ' i 11 C-Ic--, -.1-.__c_.1/4 5il I I 1 11 FROM ANY INLET OR AIR INTAKE, BUILDING OR PROPERTY LINESpenith#i 1,44.E . 23( _,-• Ai 4. ONLY ONE DUCT TAKE-OFF PER 12' OF HOOD,EXCEPT FOR AND NOT LESS THAN 10' ABOVE GRADE.MINIMUM HORIZONTALAddreset. t 0( ix.si... 1,.... .- ,__(.._ _ i*---7 ' • 1 I . UL LISTED FACTORY BUILT HOOD SYSTEMS. ' ,t 1 ,i DISTANCE BETWEEN FAN DISCHARGE AND PARAPET WALL SHALLs r r... , BE 2' FEET.PROVIDING PARAPET IS NOT HIGHER THAN ute#: - - 6-i -c . \,\/P% _ __ ___-_ ‘) , -: 5. EXHAUST DUCT SHALL EXTEND A MINIMUM OF 18"ABOVE i :I DISCHARGE. By: ; Date: 6 (5-\ ---Fietik-41 . _ . , ROOF. i il i . , 1 cfN ,. !I 5. EXHAUST FAN TO BE ELECTRICALLY INTERLOCKED WITH MAKE- I ii AUCPTIAIVRAXTYHPAIUHSOTOD SEVSEHRACLOLOAKUITNMGATICALLy 1 I 6. AIR VELOCITY WITHIN DUCT SYSTEM TO BE NOT LESS THAN 1 500 FEET PER MIN ,! . SYSTEM.T EH EE FAN• SYWSTEHEMN OFFICE COPY , . • OPERATIONS OCCUR. ACTIVATION OF EXHAUST FAN SHALL a.. " GC'e----.0.- - b- o o o - _I, _ 7. DUCT TO EXHAUST FAN CONNECTIONS SHALL BE FLANGED AND ; GASKETED AT THE BASE OF THE FAN FOR VERTICAL DISCHARGED :`' OCCUR THROUGH AN INTERLOCK WITH COOKING APPLIANCE BY --- - MEANSOF HEAT SENSORS OR BY APPROVED METHODS. • . I Z , t if int • ' .11 . FANS,FLANGED,GASKETED AND BOLTED FOR SIDE-INLET `-^aasala*.....m.- . IN / 1 .1 UTILITY AND IN-LINE FANS.GASKET AND SEALING MATERIALS . . , i i • . ,1 SHALL BE RATED FOR CONTINUOUS DUTY AT A TEMPERATURE ' OF NOT LESS THAN 1500 DEGREES. , I . 7/ . ... >I . 1- El 1 . i 8. GREASE-DUCT BRACING AND SUPPORTS SHALL BE OF NON - E. 11r711,11 4- 'qft -- ,r I. , COMBUSTIBLE MATERIALS SECURELY ATTACHED TH STRUCTURE ! . . . ____ _ . . 111 I/ I . _ .. _.... DESIGNED TO CARRY GRAVITY AND SEISMIC LOADS. FASTNERS •• 7r1.- ... SHALL NOT PENETRATE DUCT WALLS. - 0449•6 1r dr 1 \;„' 0. -F-L-Ya`N ---- //I...xi ......1. ___ ___ __ .. . ... . ,...... , 1 1 N.) .44 • 9. PRIOR TO CONCEALMENT OR USE A LEAKAGE TEST SHALL BE ________ . , \‘ 1 , PERFORMED. A LIGHT TEST OR APPROVED PRESSURE TEST . \ -1, 1 , ) ,z, / , ---._ (: .. k..%‘ L--_L 1 • - - • -------4---:- ---•1 14 i _ , A li.- FIRE SUPPRESSION SYSTEM _ _ • . --------- ... . • - r 1. AUTOMATIC FIRE SUPPRESSION SHALL BE LISTED AND LABELED - - . • , - i)1/4. _ ,,„...11 i Ni i •J FOR SPECIFIC USE AS PROTECTION FOR COMMERCIAL COOKING DUCT ENCLOSURE ''r$ q9 1,-- +---r • EQUIPMENT. 1. SHALL BE SEALED AROUND DUCT AT POINT OF PENETRATION MAKE-UP‘AIR SYSTEM ''/-6- ', ... AND VENTED TO OUTSIDE WITH WEATHER PROTECTED OPENING: •-s. 2. MANUAL ACTUATION DEVICE SHALL BE LOCATED AT MEANS OF CLEARANCE OF DUCT TO INTERNAL SURFACE OF SHAFT TO 1. MAKE-UP AIR SYSTEM SHALL BE APPROXIMATELY EQUAL TO , ..r...›. \ 4 . 1.6' 1 // 4- Date-r7 -77- 140 EGRESS MINIMUM OF 10' MAX. 20' FROM EXHAUST SYSTEM AT COMBUSTIBLE CONSTRUCTION TO BE NOT LESS THEN 18" OR 6" AMOUNT OF EXHAUSTED AIR.SHALL BE PROVIDED BY GRAVITY -.cg - \ , !..,..1„. , •54"to 60" HIGH OF NONCOMBUSTIBLE CONSTRUCTION OR GYPSUM WALLBOARD OR MECHANICAL MEANS. SYSTEM TO BE ELECTRICALLY , . . i . ; , 1.... If 1 ,t, Scale ij, r--- I --p ATTACHED TO NONCOMBUSTIBLE STRUCTURES. INTERLOCKED WITH EXHAUST FAN. • / .„.. , \ • 1 3. ACTUATION OF SYSTEM WILL AUTOMATICALLY SHUT DOWN , \ • • ' -ANS:: Drawn., -1\et FUEL OR ELECTRICAL POWER TO COOKING APPLIANCES. 2. SHAFT MAY BE OMITTED WHEN A DUCT 15 PROTECTED WITH 2. MAKE-UP AIR NOTTO DECREASE COMFORT CONDITIONS OF \ ' . (11_ , EXHAUST FAN SHALL REMAIN ON. MAKE-UP AIR TO SHUT OFF A THROUGH PENETRATION FIRE STOP SYSTEM CLASSIFIED IN OCCUPIED SPACE.TEMPERATURE DIFFERENTIAL BETWEEN 'I '', ACCORDANCE WITH ASTME 814 AND HAVING AN F&T RATING MAKE-UP AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED ' , Job4. A SYSTEM TRIP TEST TO BE SCHEDULED WITH LOCAL FIRE EQUAL TO FIRE RESISTANCE RATING OF ASSEMBLY BEING 10 DEGREES FAHRENHEIT. 14..: , MARSHAL BEFOR FINAL APPROVAL. PER UL 300 PENETRATED. WHERE THE DUCT SURFACE IS CONTINUOUSLY • Sheet COVERED ON ALL SIDES FROM POINT DUCT PENETRATES CEILING 3. AIR BALANCE OF SYSTEM TO BE TESTED BEFORE FINAL - -.../ 5. SYSTEM TO BE PROVIDED UNDER SEPARATE PERMIT. SPEC. WALL TO OUTLET TERMINAL. i.e. FIRE MASTER DUCT WRAP. • APPROVAL. TEST SHALL VERIFY RATE OF EXHAUST AIRFLOW \ AND DRAWINGS PROVIDED BY SUPPRESSION CONTRACTOR. INSTALLED PER PRODUCT SPECIFICATIONS. . • AND AIR REQUIRED. ; . Of 1 Sheets 1211=2. 52. ' d 10 X 24 PRINTED ON NO.180011 CLEARPRINT• •