Loading...
Plans (10) BU P2017 - 003 17 OFFICE COPY C *IP) CS TENANT IMPROVEMENT #3082 MARTIN W. HANSON � s� for RECEIVED LA KAM4S, OREGON °9v� DEC 122017 ��' OF Ogg 47-7 1, i E U 1-1 S ULNVOIDIG D V PROJ. No. 17520 ( I-5 TO PORTLAND 15055 S .W. SEQUOIA PARKWAY 236 (237) 239) TO SALEM � I 239' ---____3EfiZSUITE # 130 H D H > F a� � N `Jik � s PORTLAND OR 97224 w o o F �,�� � 1- 0 0 0 0 imp 14(236) (a^ \.Lq� D 0 0 0 mmlul „ I A m gg , 11 INH >- 17 '� ,9d ! , V 0 0 € (235) (241) jm \ 00 V � �, = -�; ��� ""� ���s PROJECT NARRATIVE ❑C O - -- p!(l OSA 'C.� o \ PROJECT CONSISTS OF MODIFICATION TO EXISTING OFFICE AREA TO ACCOMMODATE A NEW BIO BUBBLE AND MISC.OFFICE Q O ' - -___ _— - NEEDS..ALL WORK TO MEET REQUIREMENTS. 1� m, z �0�J J�b � •-990 TADA mRll. 9 JS i E ZZ - 01� (226 cL� � . } 10 (233) � — � Q ' I ' A''�: , 5 (22� _' ^" ap,��PoP� WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT Z a N (10 Tc O .,,.. 3 ��� NPPGeo ,� Q QN —J e I�I�IIIII 111111,1 I Tti. �,:¢,, - 5 uN ,,,,�112 A' b.- - wmmm,�J FIRE PROTECTION SPRINKLERS = 0 O) O SW 72ND AVENUE _ HEATING,VENTILATION&AIR CONDITIONING [[ COn C AREA OF WORK Z- ^� ELECTRICAL WORK,BOTH LINE VOLTAGE AND LOW VOLTAGE OO r 0 CD CO M Z efiES BUILDING INFORMATION cc op.Sec Loo Do 1 Mp OWNER: PACIFIC REALTY ASSOCIATES, L.P. O 2 X VICINITY AP ZED 15350 SW SEQUOIA PKWY#300 i°2 dLL AO NOT TO SCALE PORTLAND, ORE 97224 . (503)624-6300 (PHONE) (503)624-7755(FAX) >m I- BLDG.#: PCC BLDG#8 (pcc232) TENANT OCCUPIED AREA � W CONST. TYPE.: II-B N n (^ �' in__ �r r6,-,==u1_,_ -- t U u. Q II I THIS IS AN EXISTING BUILDING HOUSING MULTIPLE TENANTS. THE BUILDING IS A SINGLE 0 110,31 i_ .- v , (I'� r ili I _ I STORY BUILDING OF 46,445 SF AND IS FULLY SPRINKLERED. ALL FOUR SIDES HAVE W a CM , FRONTAGE Q v _ L 1. v !} " I ^, OF MORE THAN 60 FEET. a v ; wlu Pa L - - - ^, �I^�- i . L 1 co f i=r 11 IIM fm. I n — __ , � � -- ACTUAL BUILDING AREA Z .L, ,... I of v � Al B OCCUPANCY = 39,354 SF J LI 1 Mr. :.:,1 L— S-2 OCCUPANCY = 5,873 SF m v I I ,J\1 .....-_ -I I. I TOTAL BUILDING AREA = 46,445 SF EL 11 .i, 10-1.-' zi- I 49 E Vs. e . _� ALLOWABLE AREA- UNLIMITED AREA (IBC 507.3) 4 I ^ _ ^ o l _ 1 - - ____ 1 -_n `.� �1 I CI THIS ISA ONE STORY BUILDING HOUSING B, F AND S OCCUPANCIES. r- 1 == F- I THE BUILDING HAS AN AUTOMATIC SPRINKLER SYSTEM. o.oxooa. m. • THE BUILDING HAS YARDS ON ALL SIDE GREATER THAN 60 FEET. ON OARALLOWABLE AREA IS UNLIMITED Li I r 1 _ 1 it• I -- -, ril 7 ---- I „ I I IBC 508.3 NON SEPARATED OCCUPANCIES • ! ti _I ! H7 1 sl to r_cri V -- __ ._S N TENANT INFORMATION COll) 2 BUILDING PLAN TENANT: YECURIS co al AO SCALE 1/32" = 1 ' - 0" YECURIS RAISES SPECIALIZED MICE THAT ARE SOLD TO DRUG F } COMPANIES FOR THE DEVELOPMENT AND TESTING OF CD W MEDICINES FOR HUMAN DISEASES. � 0 a d- W Q N OCCUPANCY AREA OCC LOADS: EXITS REQ'D /� CC (TABLE 1004.1.1) (TABLE 1015.1) OFFICE COPY i O CD B 15,856 SF / 100 = 156 OCC D OO , _ S-1 1,609 SF /500 = 4 OCC CITY OF TIGARD i 0 i 1 } TOTAL 17,465 SF 160 OCC 2 EXITS REQUIRED 6 REVIEWED FOR CODE COMPLIANCE O r 1 0 p EM -' PROVIDED v lira.I a s Approved LL ui • IWO" a OTC: G1bSzc� sl kW- la W W 0 to Q r�-� II v �; , �{ —• CODE SUMMARY Permit#: >l77vi7-0031 -7 Qpi o cc ES , 6 / ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND LOCAL CODE 0 Q O v i' , Address: i t•e�3� $P©v O i A PK W�I (n W ,— Q 3 ' g �o REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: suite*,v / • 2014 OREGON STRUCTURAL SPECIALTY CODE '-'i l,• //// 3o REVISION m 7� err/rill� B-n / ▪ 2014 OREGON MECHANICAL SPECIALTY CODE(GMSC) By. �Ft- Dates )�_ I a_ ) a� • G • 2014 OREGON PLUMBING SPECIALTY CODE(OPSC) 0 1 • B • • 2014 OREGON ELECTRICAL SPECIALTY CODE(OESC) Addendum #1 11/10/17 • B MP v 2 I / • 2014 ASCE-7-10 FIRE CODE(OFC) ]. ' B 1 ��p ' Di'i' B • ICC/ANSI A117.1-2009 2' n1 t,1.•.:., )(�!� .j ' / /// ` ��Aip Oi ,,'� o IL�� ���•��♦���� ,����� 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE 3. �+ 'v • O�OOOO�O�d9'�ti�a►i 4. El ti T /ii �t i�) 5. 11 S-2 'r 6. LOADING DOCK .ml, �j .� ON RAD_ 1 MI _ L © 7. aa; /. I. t { • a.-:.. , � cit .' DRAWN BY: R.M.T. 11/1 /17 PERMIT N C3 BUILDING OCCUPANCY PLAN E! AO SCALE 1/32" = 1 ' - 0" AO 01 00 00 GENERAL DATA PSI)G60. - HVAC DESIGN STANDARDS 4. OFFICE EGRESS LIGHTING:ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ-CEILING AND WALL GENERAL REQUIREMENTS - 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: MOUNT. SEE PLAN FOR EGRESS PATH.USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS AN APPROVED EQUAL. - - ACCEPTABLE. _ _ V -'L 1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). -. 5. STANDARD.GYPSUM BOARD SHALL BE TYPE X,5/8 THICK WITH TAPERED EDGES CONFORMING TO ASTM _ 5. LIGHT SWITCHES.ACUITY CONTROLS PRE SET ALL.PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. C36.- - - - - Z ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY- "VACANCY"AND TO TURN ON AT LAST DIM LEVEL - - �-` 113082 2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING -- - - TENANT PRIOR TO CONSTRUCTION: - - - - CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/T THICK WITH TAPERED EDGES. CONFORMING TO ASTM - - - - a. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD - "Ni,TIN V W. HANSON n -C-630. - - - a.` EXTERIOR EXPOSURE AREAS CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE - - L WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD_ THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. - 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F. b. INTERIOR AREAS,SIZE AND.USE - c. -WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD • I. • ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT - - CIA.,KAM , OREGON, . 3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE o. CONFERENCE/TRAINING ROOMS - 'Ch O EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK LOCATIONS TO RELIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) - - - - - - DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD"A"THICK WITH SQUARE,REINFORCED, d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION ,�J C�. ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. - ��? LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA g SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UR 9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETO. . PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. . - - Ol O 4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH ZONES PROJ. NO. 175 20 INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. SYSTEM. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. 5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. WALL CONSTRUCTION EXECUTION 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. 6. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING 6. UNITS: LENNOX,TRANE YORK OR CARRIER-7.1/2-TONMAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 71/2 CARPETS. SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. : 7. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND' CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD 7• HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED ROOF MEMBRANE TO MATCH THE EXISTING ROOF: MATERIALS LIGHTER THAN 18 GA. TOA MONITORING STATION WITHIN THEBUILDING.' I- 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS 08. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. LU COMPANIES INCLUDE SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. FASTENERS SHALL BEAT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS a. ARROW ROOFING, ALFONSO PEREZ (503)460-2767 9: CURBS: 14 "HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS I -• 3. CUT STUDS AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS POSITION BELOW ROOFING. b. PACIFIC ROOFING, GUY BELT (503)640-3163 STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT c. GRIFFITH ROOFING, GREG STONE (503)643-1596 - LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE a PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE CONTRACTOR SEE DIVISION 1 GENERAL NOTES THIS PAGE. U 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS . STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. CC AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. - - AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG - - - O TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. c. CONDENSATE MUST BE TRAPPED AT UNIT. 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO - - - - - - - - O COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL ` 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR - 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. _ CO BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION THE PROJECT. - 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN - Z 4k ACTIVITIES. - - 5.'AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH) - INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND >>- 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING :CLAMPED(STAINLESS STEEL WORM GEAR). 0 > RESTROOM FACILITIES. - 6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURERS RECOMMENDATIONS. 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND C/) Y 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT - CORROSION WITH OIL BASED PAINT(COLOR GREY). - It 7. FINISH QUALITY: - - - PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER - 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND t1 N COMMON BUILDING AREA BE USED FOR STORAGE. - AREA PROCESS TRADE NOMENCLATURE RADIUS OF MANUFACTURERS GUIDELINE. - N O 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS SCREWS,BOTTLES,ETC.)AT ALL TIMES. . WAREHOUSE TAPE/FINISH COAT" TIGHT DOUBLE - 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS - _ O LLO 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. OFFICE/OTHER AREAS TAPE/2 FINISH COATS*/ SMOOTH FINISH TAPED a 6 TONS AND ABOVE MUST HAVE ECONOMIZER.: CE CO N 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, USG"FIRST COAT" - "SAND AFTER TAPE/FINISH COAT(S) b.• BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. W O I r; ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS J fn 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. SHOWN ON PLANS. c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. . N N Z d. 1 12 THRU 4-TON OSA INTAKE WITH DAMPER. 5 Z O O 18.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" 09 53 00 SUSPENDED ACOUSTICAL CEILINGR� DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS I-'- Q CO QO PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS - 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. 16.DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. CC 0 0 O SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. to II 19„.4 CONTRACTORSAPPROVED. FINAL PAYMENT UNTIL"AS-BUILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED SYSTEM,INCLUDING GRID,PANELS,AND HANGARS AND ACCESSORIES. IST - ` co AND APPROVED. A 17.DISTRIBUTION DUCTWORK: - to O `'0_X 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES,INC. r d d LL 19.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, - I - a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. FUNCTIONING PROJECT INCLUDING ALL GENERAL:MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 4• CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK BUT NOT LIMITED TO b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING: TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF INSULATION,GYPSUM BOARD,LIGHT FIXTURES,MECHANICAL SYSTEMS,ELECTRICAL SYSTEMS AND FIRE WHETHER OR NOT SHOWN ON THE DRAWINGS SPRINKLERS c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH 20.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"NIL?. 5. PRODUCTS: MINIMUM R4.2 INSULATION WITH FSK BARRIER. 21."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME a. GRID-PRELUDE 24 XL 15/16"EXPOSED TEE(HEAVY DUTY) d HANGERS 42 GAUGE WIRE OR 16-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD HANGERS AND FULL DIAMETER STRAP UP TO 18"a LARGER THAN IT MUST HAVE SADDLE TYPE CLAMP. L PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. b. TILES-ARMSTRONG FISSURED#705,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE a. BRANCH- DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 r 2/DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. c. ACCESSORIES MANUFACTURERS STANDARD - ` DEGREES. - N a 23.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. CO W TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO CONDITION SO THAT CEILING TILES LAY FLAT. - N REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. p n REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 7. AT CEILINGS OVER 144 SF PROVIDE HORIZONTAL RESTRAINT WIRE OR RIGID BRACING. - 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. U LL CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 8. INSTALL CEILING GRID WITH TWO EDGES ATTACHED TO ADJACENT WALLS. THE OTHER TWO EDGES SHALL BE - - a. 0 DIRECTED AT CONTRACTORS COST. - - - ATTACHED TO WALL MOLD USING BERC2 CLIPS ALLOWING THOSE TWO SIDES TO FLOAT. 19.DIFFUSERS: - - - - 24.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND 9. PROVIDE CEILING SEISMIC JOINTS AT LOCATIONS AS SHOWN TO LIMIT CONTIGUOUS CEILING GRID AREAS TO a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN ae PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS).-SUBMIT A MINIMUM OF TWO COPIES OF ALL NO MORE THAN 2500 S.F.THE STATIONARY SIDE OF THE JOINT SHALL PERMIT THE INSTALLATION OF A LIGHT -TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. - CC nn ---- ---.SHOP DRAWINGS FOR-REVIEW AND APPROVAL TO THE-ARCHITECT OF RECORD.ARCHITECT WILL RETAIN-ONE FIXTURE-IMMEDIATELY ADJACENT TO THE JOINT. - - b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE.W/OBD DESIGN TITUS 250;RETURN-BAR TYPE- --- 51 LL COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR.. . - 10.PROVIDE RIGID STRUTS TWELVE FEET ON CENTER EACH WAY BEGINNING WITHIN SIX FEET OF PERIMETER - DESIGN TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2 x 1/2"EGG CRATE DESIGN TITUS 50F.' 25.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS - EDGE. INSTALL SWAY BRACING EACH STRUT ALONG FIXED EDGE IN ALL FOUR DIRECTIONS a ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST CO F CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 1IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. WYE BRANCH. #/i . LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE - - - Yl INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS.SHALL BE 12.TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS.0.5 INCHES OF LEVEL. d CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE COMPLETION. - - 0 APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY : 13.BENT OR DAMAGED T-BARS TO BE REPLACED. 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE - z THE ARCHITECT PRIOR TO INSTALLATION: ' 14.REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE Q LE 26.000RDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE ACCEPTABLE APPROVED SUBSTITUTE TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL Na P374.2800 -7 DAY J H INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 15.IN THE VIVARIUMS AND VESTIBULE 121,PROVIDE 21x2'VINYL COVERED GYPSUM BOARD TILES WITH HOLD PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY 5 r' DOWN CLIP& PROVIDE A GASKET TO SEAL THE GRID TO THE CEILING TILES AND CEILING FIXTURES REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM y GENERAL -THERMOSTATS AND BALANCE SYSTEM: CO Q I. REMOVE ALL EXISTING VCT,SHEET VINYL ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 09 65 19 RESILIENT FLOORING -SHEET VINYL FLOORING 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIO TO INSTALLATION. TO.INSTALLATION OF NEW FLOORING. - 1. SEAL THE EDGES OF THE SHEET VINYL FLOORING TO THE CONCRETE FLOOR WITH A CONTINUOUS BEAD OF 1 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH APPROVED SEALANT. SET THE 4"VINYL COVE BASE INTO A FRESH BED OF SEALANT TO SEAL THE BASE TO 22.WAREHOUSE HEAT. - A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 THE SHEET VINYL. MITER THE CORNERS AND APPLY A BEAD OF SEALANT TO SEAL THE JOINT. a. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED ARE S SHALL COMPLY WITH CURRENT STATE POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. 09.65 19 RESILIENT FLOORING-VINYL COMPOSITION TILE - ENERGY.CODE REQUIREMENTS.'PROVIDE ADJUSTABLE T-S AT FOR EACH UNIT. Q 07 00 00 THERMAL&MOISTURE PROTECTION - 1. FINISH FLOORING TO EXTEND UNDER CASEWORK. 23.EXHAUST FANS: 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. 2. INSTALL TILES IN QUARTER TURN PATTERN. a.: CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. - 09 91 23 PAINTING COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A 3. AT ALL UNUSED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. INTERIOR: SONE RATING OF.9.OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. 08 10 00 DOORS AND WINDOWS - 1. WALLS - b. SINGLE FIXTURE RESTROOMS,JANITORS CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE a PRIME NEW DRYWALL WITH MILLERS HIGH-BUILD"SUPER SEAL"PRIMER. - c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: - - b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, a BAXTER AND FLAMING. (503)225-0486 - • 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. CONTROLS AS REQUIRED BY DESIGN.COOK ACE-D SERIES OR EQUAL. b. D&D DOOR - (503)205-5533 - - 2. DOORS AND FRAMES: - - d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS-. a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A c. BENSON INDUSTRIES (503)907-2200 - - - ROOFTOP MOUNTED FAN. - - L EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH RONDO,SAND AND PRIME PATCHES WITH - - - d. GRANT SUPPLY (360)887-0647 ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. - 24.HVAC TESTING: 3. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS(WIM),OR APPROVED. SUBMITTAL - - a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. C. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'SEQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, APPROVED PLANS AND SPECIFICATIONS. 4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, AND FINISH WITH SATIN OIL ENAMEL - 0 FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. . b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. - CO . 5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. _ r 3. CEILINGS: c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND .O 6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N . R - - W } a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO FILED WITH PACTRUST: 7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. 25.PROJECT CLOSE OUT DOCUMENTS REQUIRED: - - Z B. DOOR FINISH SUBMITTAL CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE a AutoCAD FILE SHOWING AS-BUILT INFORMATION. W Y HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH WITH MILLER'S 6200 OR 4480. - O ll APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT - b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. 4. GENERAL NOTES: - d' SHALL APPROVE CONTROL SAMPLE:FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS a HARD COPY OF AutoCAD FILE ABOVE. W Q N PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL a KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER - 1 1 H - (\I SAMPLE. SPRAY. d: OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. CC QW 0 9. ALL INTERIOR GLAZING SHALL BE TEMPERED. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. - O d 10.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE a DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND 26 00 00 ELECTRICAL: DESIGN/BUILD W O CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH RAGS AT THE END OF EACH DAY. GENERAL W C(i) WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. d UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING - 1 09 00 00 FINISHES - AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. - 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR C 1/ 0 0 HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. 0 V U 5: Z GENERAL - a PROTECT WORK OF OTHER TRADES - - - LL - 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDINGW g C 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. - W 1 1 1 IL U) H 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: - 10 00 00 SPECIALTIES 3. ALL ELECTRICAL PENETRATIONS INTO THE VIVARIUM TO BE FULLY AIR SEALED. - < 0>,,, EC a FLOOR COVERINGS,BASE AND TRANSITION STRIPS, - 1044 16 FIRE EXTINGUISHER3 - - 4. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. 0- Q Ln 0 -- b. PLASTIC LAMINATES - - 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN.SEMI RECESSED CABINET AS INDICATED ON PLAN) 5. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. - - In (1 r d c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) - 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. 6. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER _ d. PAINT - - IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO 21 00 00FIRE SUPPRESSION : DESIGN/BUILD REVISION TENANT'S MOVE-IN. e. TILE,MARBLE,GRANITE,STONE GROUT AND SCHLUTER TRIMS - 1. PROVIDE SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE 7. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN.ON PLAN EQUAL TO f. TOILET PARTITIONS CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD -1-FOOT CANDLE. - g. HARDWARE CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO - Addendum#1 11 10/17 INSTALLATION. 8. EXIT LIGHTS:RUUD LIGHTING PLASTIC LED.EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK - 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. WITH BATTERY BACKUP.r 1• 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET NO'OOPS RINGS ALLOWED 9. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE)OF TILE 23 00 00 HVAC : DESIGN/BUILD 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. 2. (CERAMIC;QUARRY OR PORCELAIN) : a. TRANSFORMERS TO BE ENERGY STAR LABELED. 09 21 00 GYPSUM BOARD GAS METER b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. 3 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C GENERAL METER IDENTIFICATION NUMBER AND TENANT c• ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR4'• TO TENANTS MOVE-IN. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS 4. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR OPERATION: EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM- 5 PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES - HVAC-BID PROCEDURE SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN ASSEMBLY AND CASE. INTERMEDIATE STUDS. STAGGERALL VERTICAL AND HORIZONTAL JOINTS 24"aa(OR ONE STUD SPACING), PROPER WORKING ORDER. 11.FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCESS BELOW FLOOR,USE WIREMOLD RC7 - 6• EACH SIDE AND OPPOSITE SIDES- FLUSH POKE-THRU SERIES OR EQUAL.'FOR SLAB ON GRADE INSTALLATIONS USE RACO#5511,2 AT EACH 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH 7. 5. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN UNIT- LOCATION TO SEPARATE POWER AND DATA WITH 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. FINISH COATS.APPLY USG SHEETROCK BRAND FIRST COAT: PAINT AS INDICATED. 3. UST TONNAGE OF EACH UNIT. 12.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. 6. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH 13.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS COAT: PAINT AS INDICATED. -. HVAC-DESIGN PROCEDURE DRAWN BY: 7. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.VASYSTEM PER DESIGN STANDARDS 14.00CUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. C. METAL STUDS - _ LISTED BELOW. 1a TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT 8. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL AT VIVARIUM#2 ROOM#123,EXTEND EXISTING VENTILATION SYSTEM FROM VIVARIUM#1 - AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE 1 1/1 /17 MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. : PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS: - 9. AT ALL EXISTING WALLS,REMOVE ALL NAILS SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND - REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH 16.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE: PERMIT PATCH HOLES READY FOR PAINT. - NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. 10.REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR INCLUDE THE FOLLOWING: - 17.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION UNUSED DATA PAINT - - a DUCTING AND SIZES BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. 11.UPON REMOVAL OF WALL BASE.REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFFUSER - 16.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION WALL CONSTRUCTION MATERIALS - - c. ROOF EQUIPMENT,SIZES AND LOCATIONS OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING 1. PROVIDE STUDS,TRACKS,BRACING FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE d. UNITS REQUIRING DUCTED SMOKE DETECTION OFFICE LIGHTING - INSTALLATION. - - - e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH 1. OFFICE LIGHT FIXTURES-LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL f• ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS BALLASTS) PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS: 2. VIVARIUM LIGHT FIXTURES-LITHONIA SRH 3 32WT8 FSF A12125V MVOLT ADVANCE OR EQUAL:(NO SYLVANIA Al DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. g. ZONE DIAGRAM BALLASTS) -(4)FIXTURES TO BE SRH 2 32WT8 FSF A12125V MVOLT WITH RED SLEEVES OVER TUBES. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 3. PROVIDE A PROGRAMABLE TIME CLOCK TO OPERATE THE"WHITE"LIGHTS IN THE VIVARIUM. Ss GENERAL NOTES: ���`` _,�K,' AREAOF WORK 1 SEAL ALL PERIMETER EDGES OF GYPSUM BOARD WITH USG SHEETROCK ACOUSTICAL SEALANT #3082 ��' ' )12 NEW 42"WIDE HM DOOR AND FRAME WITH POWERED OPENER, ACTIVATION MARTIN W. HANSON BUTTONS, HALF LITE KIT, AND DROP SWEEP. ALL SS HARDWARE / 3 NEW ELECTRICAL DROP WITH FIXTURES AS SHOWN. cp CCLL,A KAMAS, OREGON r� rel r. ■1 4 NEW WALL OUTLETS - 3 OUTLETS ON 20A CIRCUITS EACH. ,'�4) O���O • ! f� , 1 • • I I • 5 VIVARIUM BUBBLE BY OTHERS �. �; ��� aI, ��, y ;}, �I_ ,-.-, IIS 4l [1 VA - OF 10. 41 ,1) OFFICE a i'{ cOFFICE .- ® 11za1 N 1 OFFICE OFFICE OFFICE OFFICEOFFICE OFFICE O. 6 NEW EPDXY FLOORING WITH FOLLOWING REQUIREMENTS PRO. . NO. 1 7520 11741 1175111761 177 i= 105 -C-, 11061 • NON SLIP TEXTURE. 4 11071 IA ► EP OFFICE - • APPROPRIATE FOR CHEMICALS SUCH AS ETHANOL, BLEACH, ISOPROPYL � 108ALCOHOL, AND ISOFLURANE. ENTRY • APPROPRIATE FOR ROLLING CARTS, SHELVING, TABLES THAT ARE PUSHED ky p���� 101 v� (I ; 1 - , , • , Ta DN ill P'"�i JmA �a. a'-m' EC/ FEC ' } }- DED �` UND AT TIMES. 4"ARCOVED RUBBER BASE WITH SEALANT AT FLOOR FU PC 1ma CIRCUIT _ w ■ I 4 E::::::::::::: I� a .A ,T� 7 CONTRACTOR TO DESIGN THE SUPPLY AND RETURN AIR DUCT IN A WAY WHICH I - ■: • �. ■ i i' m 7 A!�� WILL ALLOW YECURIS TO STERILIZE THE NEW VIVARIUM SPACE USING HYDROGENIII • 17 PEROXIDE VAPOR AFTER THE CONSTRUCTION IS COMPLETE WITHOUT IMPACTING■ E ■ ■ a 16 GOWNING --_ . OPEN OFFICE U ■ �rla■�■'■ . oz , THE EXISTING VIVARIUM. THIS INCLUDES EXHAUSTING THE H2O2 VAPOR AFTER �� !■ ■ ■ � _ — R� rOFFICE COMPLETING THE STERILIZATION PROCESS. CCaba I,oa 11os1 Q O ::: ,.` 1❑ i (i) C I 18 XJ�118 8 ALL CONSTRUCTION TO BE PERFORMED INA MANNER THAT WILL MINIMIZE _ CO'il =■■ RECEPTION/MAIL tl �U� t DISRUPTION TO THE EXISTING OPERATION AND MINIMIZE THE NEED FOR z� '� �� TION a. ® © SHWR r �. CONTRACTORS TO ENTER THE "CLEAN" SIDE OF THE ANTI-CHAMBER. O >- 11 ''p 3 o 04 z ,/011 CONSTRUCTION NOISE TRANSMISSION MUST BE KEPT TO A MINIMUM,1 V PARTICULARLY DURING THE DAY. z (id. OPEN OFFICE 9 ADD DRYWALL TO TOP HALF OF EXISTING WALL TO STRUCTURE AND HENRY 'C Q N i1U• 172 O l D till II■ I - I� ' Mir ■ 4 ki ,_< II U ■ BLUESKIN SA SELF- ADHESIVE AIR BARRIER MEMBRANE. DRAPE FOR DEFLECTION T O O 00 LO CONFERENCE - .� •I� l � ` C •-- ■ HALL ► (r 164 T5 C6 ^ 10 -'`- In 1 .C5-' "q�- ■ 11,01 BREAK 10 NEW SHEET VINYL TO MATCH ADJACENT EXISTING Q O 9 I WA CIRCUIT ( DED 11 In 1 0 • ■r „5i (j) �• L.T 60'�,F�z..x ," - 3 ir EP DED e I I i 11 EPDXY WALL PAINT TO MATCH EXISTING. N N II4. lin L Z z co co CIRC STORAGE -ft, 1_,_ SHWR MEN I► E� J 12 INSTALL METAL THRESHOLD TRANSITION ~ �� 00 ,• o 156illcc O J n"n 114 113 1-) i1 1J J�, TISSUE CULTURE 'C 13 INSTALL STAINLESS STEEL CORNER GUARD - 48" H X 2"WIDE EACH SIDE. Q co \\ NI'u VEST -- 11211 ( rlh (I`) :'D ® CIRC 120 LOO =X 1 153 CC in cc in in i( ......._ 11 z,l 11111I E , 11s 14 INSTALL TENANT SUPPLIED CHEMICAL HOOD - LABCONCO 8' PROTECTOR LX '–0 D LL ft VIVARIUM#2 -� JAN BENCHTOPTOINCLUDE: r�'^' `_- _i� ,, i ' 123 m'i i' n c_� 64 E� . DEDICATED 20A 120V POWER " 1 1 2 -� N DOOR BUTTON 1.�" ,t „ ,^ .-. 8;0: - 111 ■= N ({1) } ■ - - - . CONNECT TO FEF TO ACTIVATE WHEN HOOD IS TURNED ON r —• Ind _: rl 19 I 13 ® I • • RE-ROUTING EXISTING EXHAUST DUCT- REPLACE FAN • ♦.,'i♦ n rIII FEC r ; IU : WATER SUPPLYI— b EP -} 5 EP 1 EP' DRAIN TO MOP SINK IN JAN 118. DOCK BUTTON a OPENING HEIGHT AT II'-6'AFF. \- 1 r p 1 .. _ N / { ''� 14 LNEW20A DED. U •45 ��i' ' 15 PROVIDE ALTERNATE PRICE TO INSTALL HENRY BLUESKIN SA SELF-ADHESIVE AIR CO W IA EP EP BARRIER MEMBRANE TO TOP OF EXISTING WALL WITH LATH TYPE HOLD DOWNS pn / OFFICE - 15 VIVARIUM#1 - U LL 158 ► 122 - _ 16 RETURN AIR CHASE WITH VENT NEAR FLOOR LEVEL. a OPEN OFFICE STORAGE P 0 .- . �I�' - r ,=v a * 0 F ,JR AND c 5!E i 1sa 11731 +12' EP _ •F D 171 RELOCATE DOOR AND FRAME. C ► 18 — — - ADD POWER AND DATA ' 1---- --- /71) IMI(i) / CONFERENCE iiisi 77 CAO r _i O LA16 19 RELOCATE POWER FROM NEW FUME HOOD LOCATION * N 2 15 _' (', 20 INSTALL EXHAUST VENT FOR FUTURE DRYER WITH BOOSTER FAN. C 00U - 159 ,Ga• 445 Z R \ Ota'° - ► 1 FINISH MATERIALS _II AT 6c r3 Bcx OPEN OFFICE O ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. 5 U A 157 m ll F° �;• CARPET CUT PILE: y' x,.11 VT �` 15 EP I J�`. - fr CP PATCRAFT - 10200 -WINDSWEPT ENCORE - 30, 00583 FLINT OVER JUTE HAIR PAD dia ,-, F1)., O O O O CARPET LOOP PILE: 1 IT Tl LAN i- _c MEN D 1t63 °1 as J I (I =I _; LP PATCRAFT - 10147 - FAMOUS LAST WORDS II, 47402 THIS WONT HURT, DIRECT GLUE 4 \. -. BREAK 4. .'- -- -- _. "' : ws / T (� (� I I 11' •— 115 �/ Ste,- WALK -OFF MAT .O VAN DIJK, PROTECT SUPER, CLEAN-OFF ZONE # 61 rt= . CIRC. ► �- ► _� 165 ...3-t-1- � Ai imam ■, \ �1 Irl . J, I �' PORCELAIN TILE AND GROUT OFFICE IT 162ICE ► ' ` MECH ' ► POT-1 FLORIDA TILE, LAS OLAS LS5507 SEA OATS 19" X 19" (FLOOR FIELD TILE) 160 1za CFEeV POT-2 FLORIDA TILE, LAS OLAS LS507W SEA OATS 13" X 13" ALL TILE) FE ' WAREHOUSE O GT-2 LATICRETE 39 MUSHROOM (NON SANDED) � 124 n H, f h ei1 Tfnrh 0. WOMEN EN Y \ / ' rncRowavE VINYL COMPOSITION TILE VCT ARMSTRONG STANDARD EXCELON 51908 PEWTER, 12"x 12"x 1/8" - I '��'" - _ (SHIP/RECV LC` �oR SHW ' 125 SHEET VINYL - 1 �0 171 E SV MANNINGTON COMMERCIAL, BIOSPEC, 15146 BRIGHT WHITE, WELDED SEAMS g' _ �fi 6— ❑ _ ♦ (I ._,N — ( ♦ p ■ BASE 0 {il (`[j I RB1 JOHNSONITE 4" RUBBER BASE, 63 BURNT UMBER CO W1/ CIRC. 2„0,I _ RB2 JOHNSONITE 4" RUBBER BASE, 24 GREY HAZE cc ; 5,1 _` WAREHOUSJ I li I _� USE FLAT AT CARPET AND COVE AT RESILIENT FLOORING 6: 169 A'S IF PAINT: C/^J Z CIR PT-1 MILLER 4480 PREMIUM SATIN 0210 HIDDEN COVE, SATIN LATEX. `� ' U EL PT-2 MILLER 4480 PREMIUM SATIN 0542 CAPTAIN NEMO, SATIN LATEX (ACCENT COLOR) 1 PT-3 MILLER 3780 PREMIUM FLAT- MIX IXX79W (WAREHOUSE WALLS) 1 < Q ON N ` LAMINATE: PL-1 WILSONART D92-60 DOVE GREY, AT ALL FACES 0 O LOADING DOCK PL-2 WILSONART 4886-38 PEARL SOAPSTONE, COUNTER, B.S. AND SELF-EDGE. 0 PL-3 WILSONART D92-60 DOVE GREY, WAINSCOT WALLS PL-4 WILSONART D921530-60 BEIGE, TOILET PARTITION AT PORCELAIN TILE RR. O O CONTACT TECH SERVICES: 800-433-3222 U Z CAB PULLS (#605 POLISHED BRASS) w I I I U DOCK HIGH ON GRADE 1 1 1 LL I b, DOORS, HARDWARE AND FRAMES Q (O O w U ` DOORS - BIRCH d ui Q IS O FINISH CHERRY STAIN to- 0 r CL `�I HARDWARE 605 POLISHED BRASS FRAMES PAC RED REVISION 4.8' LE' e8' m CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. CONSTRUCTION LEGEND Addendum #1 11/10/17 I Addendum #2 11/14/17 I EXISTING TO REMAIN 1 'Hi) 1 I P E EXISTING TO BE REMOVED 2. « ,>x,..>xY„ NEW STANDARD WALL WITH INS.Vir 3 N - I w NEW STANDARD WALL WITH INS.TO BLDG.STRUCTURE ABOVE. 4. = O DUPLEX RECEPTACLE 5. FOURPLEX RECEPTACLE 6. 0 o 1 0 �n 11 I, 1I uDEDICATED OUTLET FLOOR MONUMENT W/SERVICES SHOWN DRAWN BY:IF OJ POWER DROP FROM CEILING R.M.T. 0 PARTITION n TITION AND POWER PLAN EPO INDICATES CIRCUIT ON EMERGENCY POWER BACK UP. 1 1 �1�1 7 SCALE 11/88" =111-0'1'\ r Ll� SPECIAL OUTLET PERMIT 4 TEL/DATA MUD RING WITH PULL STRING © ELECTRICAL PANEL 0 POWER J-BOX ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA G FIRE EXTINGUISHER IN RECESSED CAB. A2 O FIRE EXTINGUISHER-SURFACE MOUNTED Q THERMOSTAT AREA OF WORKo_ ) �. i 1 cs, #3082 I I a MARTIN W. HANSON / IU CLA KAMAS, OREGON GENERAL NOTES: �Q� �n ' I- ■a i .--t—.—,..lar -—nom , : 1.-1 91 1 NEW CEILING GRID AT 12'A.F.F. t,� Og:� -s■■■■�■iii■■■■■iii■■■■J■rii■■rae our■■■U■■■■L ,-__—_.■■U■■iI■raaahuw■e■■i.■■lsl OF ■■■■■,i■111■■■I- ,■Ii1■■►119■Ii1■I� ■■1 I ■■■ ■_• u ■ ' ii■lIIIir1SIIIir■■■IIII-1■"■■I■■■e■ 2 DEMO DRIP C ING 'ND INSTALL DRY WALL CEILING I �::: : I::: 1. 111 1.I I:i ::: ::: ::: o:i:i ::: ::: 1111■ ■e. MEM PROJ. No. 17520 II■■■i■■■®1111 ::: ::: ::: ■�1'■u®1111■■■111■iueeeeer111 ■■ear e111e■o■rot ,__ ___ .__.�■e■ne■11ee■■■■■■®lle ■e■■■elll� 1111■■■coal 1111■®1111■■ 3 INSTALL NEW LIGHT FIXTURES. :... _ - 1111■ ■ee ■■■ 1111■ ,1111■ 1111 1111■ 1111■ ani, 4;,m,--am.;,„,iii .viiiiiiiii iii ■■e eee ere 1111■ 1111■ 7■■ 1111■ ear 1111■ :::■■� :■III■:::■■:::III EE■■I:: ■III■:: ■ : 1 ._ �0 )_ ®..■ I■®1.IMIIIII:::■�®II■ ::e:::■IIIY:::■:::■1 :::►1::: ■■�- i� �■ 4 RELOCATE SWITCHES AND OCCUPANCY TIMER FOR VIVARIUM#1 ROOM 122 TO h■■_®e.I�II'I'II II:�■��■e■1llee■■�,,41�I III I•■■■1 le `.■1 iuiiu III I,■e®II■■■-■r�I III I� e_■_e_I■e■.■ VIVARIUM#2 ROOM 123 SWITCH BANK Ha+ramaTill■lief■ice 'mmunip sil1■ 11 e�fsi I■il� ■1111■■II , ■■NIJ■M�MMflt IllL�e1.r�1N■ am ■ ri■ DF- -® I ■� ■■� _ :.. 5 REMOVE SUPPLY DUCT AN INSTALL AN EXHAUST FAN A T-STAT 0 _:.�■■■I'l■■■■■■■■■■■■lJ■■■■0■I l■ ■■■t.■■1, !td ■!:::■■■f:::■ 1111■ ■■U■■■■ ►4®,. .■ w ■ ■■ii■III■01111E■I!�I®■■■■■■■■■■■I9■■■■■■1 I■' ■1■■ � ; __ I ■ ■■■®ur■_,�■®■mms: H ■■e ■e■ ' �:::e,II■■■■i■■■i■i■�■■■i■■1 I■■■■■■■■■1! !�■■i 1�®flIl■■■■®■■■iIIil,\le ®■n■®o■■II,I,� ::: Y ue ■ ■ i ..1 ■u u■ n- sel■■ ■ 1 ■n !!:j III % RACO HEAD ��Y` `'i.�j - FLOOR AND/OR ROOF STRUCTURE I ` ',( 3-1/2" 24 GA METAL STUDS AT 10'-0" O.C. TO BLDG. cr ARMSTRONG BERC2 CLIP PAS ALTERNATE MEANS OF CONSTRUCTION a STRUCTURE ABOVE FOR WALLS LONGER THAN 12'-0" FOR THIS PROJECT.) 8 #3082 �' WITHOUT INTERSECTING WALLS FASTEN EACH END EXISTING PLYWOOD ROOF DECK ❑ W/(1) #8 SHEET METAL SCREW ADDITIONAL HANGERS AT ALL MAINS WITHIN S' OF THE PERIMETER o MARTIN W. HANSON APPROFED EPERIMET STRUT AT 12'-0' O.G. EA.WAY BEGINING WITHIN U i 6' WALL ATT INSULATION 4' CENTERED OVER 6'-m' OF THE PERIMETER G EACH CEILING SECTION.SEE STRUT DETAIL 2 D cp CLA'KAMAS, OREGON I t —.— T PROVIDE HC SIGNAGE FORLALL � - EXISTING ROOF INSULATION STRUTS AT FIxTED EDGES NOT ATTACHED TO THE BUILDING TO O NEW AND EXISTING HC RR'S KROY it ��oy �• •� 'I'm TYP. @FASTENING POINTS spill ® , . ♦♦ uAvE a WAY LATERAL BRACING FROM ruE MAIN RJNNER To THE O w?tettlf ii�l or I� V #2835207 BLACK (MEN) KROY�� EXISTING SUSPENDED CEILING � BUILDING STRuciuRE ABovE. cn z z � )Z #2835209 BLACK OMEN �/ OF Og:� RACO TRIM � 44p4 ® Q E / ° - —I-I&. 0 PROJ. No. 17520 ill 2" DEEP LEG TRACK / 0_ NE" ei / / I •O ; LU d ¢ ADDITIONAL 6 i -3-1/2" BATT INSUL. r 2.75" DEEP LEG TRACK HENRY BLUESKIN SA SELF- ADHESIVE r Z O } I SWITCH GANG I w AIR BARRIER MEMBRANE. DRAPE FOR T i LOCATION ¢ -3-5/8" MTL. STUDS @ 24" O.C. / O 5' ¢ DEFLECTION ,_ � - 5/8" GYPSUM BOARD TYPE X BOTH SIDES E Z U B BATT INSULATION —is' CROSS MEMBERS BETWEEN MAIN t U71 61 yT ,., —_CENTER LINE OF STUD . MAX RUNNERS W I Q W W 3 5/8" METAL STUDS 24" O.C. MAIN RUNNERS AT 41-0' O.C. p ELECTRICAL �i H 0 ,_ 6'-m' MAX - SUPPORT WITH '12 WIRE AT 4'-0' O.G. (p 3-1/2" BATT INSUL. IN SOUND ATTENUATION WALLS OR WITH •I0 WIRE AT 5P-0' OC. w OUTLET 2 F- II 5/8" GYP BOARD COUNTERSLOPE HANGERS IF MORE CO. OR J-BOX 0 O w p ( , / - THAN I:6 OUT Gr PLUMB , O D = US. 4" RUBBER BASE-TYP. al ./ UNDERCUT D••R p H o EC EC 00el SEGUR= ALL HANGERS To SLOG. AS REQUIP,ED •Se ATTACH BOTTOM TRACK TO FLOOR WITH STRUCTURE ORA TRAPEZE FOR b mup is POWDER DRIVEN ANCHORS AT 12"O.C. . DUCT AND/OR PIPE WORK FINISH FLOOR FINISH FLOOR . NOTE: CEILING SYSTEM TO BE USED SHALL BE CLASSIFIED AS 'HEAVY DUTY'. r I r I I I i z �-. tee] ALL CONNECTION DEVICES TO BE IBC APPROVED TYPE AND HAVE 0 100'CAPACITY - CO 1 RACO WALL SECTION W/ SOUND INSUL. 5 WALL DEFLECTION DETAIL PARALLEL TO SUB PERLINS 9 CEILING BRACING DETAIL 13 MOUNTING HEIGHTS z 0 N A4 SCALE 1" = 1'-0" A4 SCALE 1" = 1'-0" A-4 NOT TO SCALE A4 SCALE 1/2" = 1 ' - 0" _ 00 Lo CC cON 2 X 4 BLOCKING Q 0 O N z � Z/&/ SEALANT AT ALL CONTACTED EDGES 0 EXISTING PLYWOOD ROOF DECK 8"MAX.441 8"MAX./ / / CO co CC Oa 00 ` i_��r / EXISTING ROOF INSULATION / '� Lo ` �i` ) -� _ — y — r a ISI ® �� ®♦ � m m m � � Q Q / EXISTING2X4@24" O.C. / m y ` m Ca c ✓ n mQ0 `pm m meO 1 a a VI— 6005PS-300D ARMSTRONG BERC1 CLIP m o a�eMSTRCNG EERc7 CLIP m SOAP PAPER TOWEL SAN.NAP. PAPER TOWEL/ - RECESSED �y FI w 24' O.C.FOR WALLS U° To 24' ATTACHED to GRID ,, UNATTACHED To GRID . DISPENSER DISPENSER DISPENSER DISPENSER/ TOWEL. .-. LL 2" DEEP LEG TRACK U-' 16' OG.FOR WALLS UP TO 30' I DISPENSER C9 a / . HENRY BLUESKIN SA SELF-ADHESIVE ATTACHED WALL UNATTACHED WALL N W SUSPENDED CEILING 12' AFF. AIR BARRIER MEMBRANE. DRAPE FOR uaNGER wleE wi STRUT O Q = 2.75" DEEP LEG TRACK . DEFLECTION HANGER WIRE e'Max / 5/5' TYPE X GYP. BW. AND SPLAY WIRES PER O j� BOTH SIDES SCREW ATTACHED - .. L ` CEILING BRACING DETAIL — p- 0 \V^y POP-RIVET /Y o v e e e e 0 0 0 0 0 0 — MAIN BEAM CROSS TEE � � n --. ---- —III --- CENTER LME OF STUD --- --- -- .. e I) o e e ! e a e e e e w OO c a '� I --- "� r_CR055 TEE 4:. o O O G O O G O O O O O I R-II BATT INSULATION BATT INSULATION ��o X 00 I- 4' RUBBER BASE TYP, IN FULL SEALANT FREE END ♦ FIXTED END t ATTACH BOTTOM TRACK To FLOOR WITH .� 3 5/8" METAL STUDS 24" O.C. 1/5'ANGLE MOLDING I (FULL 24"TILE SECTION) L �' POWDER DRIVEN ANCHORS AT I2' O.C. . POP-RIVET r r ANGLE MOLDING UNATIA THIS SIDE Z SEAT COVER TOIL. PAPER/ GRAB BAR MIRROR 5/8" GYP BOARD EXPANSION JOINT p DISPENSER SEAT COV.DISPJ J '� / NOTE: CEILIN{.SYSTEM TO BE USED SHALL BE CLASSIFIED AS'HEAVY DUTY ALL SAN.NAP. j/ ILI CONNECTION DEVICES TO BE IBC APPROVED TYPE AND HAVE IOC* DISPOSAL 5 U CAPACITY CO Q 2 FULL HEIGHT DEMISING WALL 6 WALL DEFLECTION DETAIL PERPENDICULAR TO SUB PERLINS 10 CEILING SEISMIC JOINTS 14 ACC. - MOUNTING HEIGHTS 0. A4 SCALE 1" = 1'-0" A4 SCALE 1" = 1'-0" A-4 SCALE 3"= P-0" A-4 NOT TO SCALE Q 1'-4' EXISTING 8 3/4"GLU-LAM BEAM ROOF DECK OR BEAM RAW STYLE co."- /� V 1' 1 I/2" RECESSED REVEAL 2" DEEP LEG TRACK HEADER. CONCEPT ASUSPENDED CLG ASSEMBLYAllin /. WALLS 'I.4S1RDT .~ MrLL O 2.75" DEEP LEG TRACKCO IMMIN S�� LAIcc k al .111.11.1ra111111 �� • HENRY BLUESKIN SA SELF- ADHESIVE S I- >- .. AIR BARRIER MEMBRANE. DRAPE FOR 20 GA 3 5/8' METAL STUD BRACING DEFLECTION 0 11/4' CHROME ROD 4 FLANGES TO ROOF STRUCTURE AT 10'-0' BATT INSULATION PROVIDE 2 X S BLOCKING IN STUD W Q N OC LW (2) 08 SHEET METAL SPACE FOR ATTACHMENT Q O SCREWS AT EACH END. BRACING .� 3 5/8" METAL STUDS 24" O.C. TO BE PROVIDED WHERE DISTANCE BETWEEN PERPENDICULAR INTERSECTING ALL SI IEEE SUPPORT SURFACES D 0 O E N TE OR HORIZONTAL BRACING BE5/8" GYP BOARD SHALL BE I)) I TE MELAMINE 0 BETWEEN WALLS EXCEEDS 12'-0' OG /� / O r ) 0 -. Q 3 WALL BRACING DETAIL r., WALL DEFLECTION DETAIL AT GLU-LAM BEAM ® ROD AND SHELF DETAIL icaz. ›-- P S o A-4 SCALE 3" = 1'-0" KA4) SCALE 1" = 1'-o" A-4 SCALE 3" = 1'-0" REVISION Addendum #1 11/10/17 42' 42' 1. EQ. Ea. Ea 2. ❑❑❑ 3. TYPICAL STUD 4. R 5. CD AND HLF T ❑ ❑H: 6. 0 TYPICAL TRACK INSTALL STUDS ' MI SAME ❑❑❑ cs - DIMENSION (10MIN.) FOR DRAWN BY: BRIDGING ALIGNMENT - - Ilfr,01 15' DEEP ❑ 11/1/17 PERMIT POWDER DRIVEN ANCHORS AT 12' O.G. \ (I) 010-16 SCREW CS PER STUD FLANGEw PLAM BASE - A4 CWALL BASE DETAIL C CABINET ELEVATION I SCALE 3" = 1'-0" A4 SCALE 1/2" = 1'-0" GOWNING 102