Plans (6) BU P2017 - 00047 PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES /Y Q I 00 00 GENERAL DATA 3. SYSTEMADORDESIGN CRITERIAEMIZONESOR 3-T TON UNITS BASED A USEBEXPOSURE LTIPLEIZ. 01) `L DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. GENERAL REQUIREMENTS INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE TENANT IMPROVEMENT for 'a 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON EACH SIDE AND OPPOSITE SIDES.. ZONES. STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. 5. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. #3082 ,, 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. 2obpl 74 lS 7S� SPEC ®FFICE COPS MARTN W. HANSONNOTIFY ARCHITECT OF ANY DfSCREPANCfES PRIOR TO STARTING THE WORK. 6. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH =3. CONTRACTOR ANp ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE 1N5PECT10N OF ALL EXISTING COAT. PAINT AS INDICATED. 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 7. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 518"GYPSUM BOARD OVER TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE METAL STUDS. 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED CLA�KAM S, ()RECON THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 8. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT. QUIETJOINT SHH WHERE WALL TO A MONITORING STATION WITHIN THE BUILDING. PROJECT NARRATIVE R CEI r u 3 Q 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS PROJECT CONSISTS OF REMODEL WORK TO 3,101 SF OF EXISTING OFFICE SPACE. WORK SHALL �(" '�� EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. OF 6.' DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 9. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND INCLUDE BUT NOT BE LIMITED TO DRYWALL/METAL STUDS, SUSPENDED CEILINGS, ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE PATCH HOLES READY FOR PAINT. 9. CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS Cr Eg 2 2 2�11 BELOW ROOFING. DOORS/FRAMES AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS.LEFT IN THE TENANT SPACE AS rr ry + �y SURFACES PRIOR TO INSTALLATION,ASED BY WE AS FINAL CLEAN UPTRUST), . PAINT AND ALL PREPARATION OF SUBSTRATE 10 PA NTR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF I O e, �'►.1A Zf PROJECT #17060 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 11.UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. r STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT1UILPIN D�� I�1`� INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. WALL CONSTRUCTION MATERIALS 1. PROVIDE STUDS,TRACKS, BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE c. CONDENSATE MUST BE TRAPPED AT UNIT. HEATING, VENTILATION &AIR CONDITIONING WORK Eiml 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. INSTALLATION. 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS"TO PROTECT EXISTING 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE WI SUPPORTS PER CODE. PIPING SHALL BE RUN W CARPETS. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. CLAMPED(STAINLESS STEEL WORM GEAR). H ROOF MEMBRANE TO MATCH THE EXISTING ROOF. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECT€D FROM RUST AND BUILDING ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED PSI)G60. CORROSION WITH OIL BASED PAINT(COLOR GREY). BUILDING INFORMATION TENANT INFORMATION E l COMPANIES INCLUDE: 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND V a. ARROW ROOFING, ALFONSO PEREZ (503)460-2767 AN APPROVED EQUAL. RADIUS OF MANUFACTURER'S GUIDELINE. • OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: 2obp174-15786 SPEC b. PACIFIC ROOFING, GUY BELT (503)640-3163 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: 15350 SW SEQUOIA PKWY#300 C-36. g c. GRIFFITH ROOFING, GREG STONE (503)643-1596 PORTLAND, ORE 97224 OCCUPANCY: B 5-2 a. PROVIDE ECONOMIZERS ON ALL UNITS. IN 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. AREAS AND COMMON AREA. I COORS TO BE SWEPT OR VACUUMED DA{LY. C-630. (503)624-6300 (PHONE) FLOOR AREA: B 1,687 SF 4 c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. 11.PROVIOE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO 7. AT TOILET ROOMS USE 518"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F. (503)624-7755 (FAX) S-2 1,414 SF O O ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION: EXCEPTION AT d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL TOTAL 3,101 SF CA M BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION LOCATIONS TO RECLINE PLASTIC LAMINATE OR TILE WAINSCOT.) 15.ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. BLDG.#: D (2obp174) ACTIVITIES. 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD'A"THICK WITH SQUARE,REINFORCED, 16.ALL UNITS IN BE INSTALLED WITH HINGED SERVICE DOORS. I� 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. 17,DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. CONST.TYPE.: V-B CODE ANALYSYS RESTROOM FACILITIES. 9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. NON SPRINKLERED ALLOWABLE BASE AREA FOR"B"OCC 9,000 SF .,1- 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM 0-1047. 18.DISTRIBUTION DUCTWORK: a n1 PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER11.U5E GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH MOST RESTRICTIVE USE IS"B" COMMON BUILDING AREA BE USED FOR STORAGE. a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. TOTAL BUILDING AREAS: CR SYSTEM. EXISTING BUILDING HAS MINIMUM OF 40'FRONTAGE ON ALL Ocp in 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. B 8,976 SF iiO p WALL CONSTRUCTION EXECUTION FOUR SIDES. ch 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH S-2 2,274 SF Z p,O „N. N. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING MINIMUM R4.2 INSULATION WITH FSK BARRIER. TOTAL 11,250 SF W d''1 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW BASE AREA 9,000 SF H C/� A cV ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD o 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. MATERIALS LIGHTER THAN 18 GA. HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. 75% INCREASE FOR FRONTAGE 6,750 SF e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS TEES SHALL BE MAXIMUM OF 45 TOTAL ALLOWABLE AREA 15,750 SF co,..a m cin 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS ) O 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS, EXTERIOR GLASS,ETC. INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. DEGREES. o H iin in 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. 15,750> 11,250 SF NON SEPERATED USES UNDER IBC 508.3.3 �O x X 20.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. ALLOWED. ,-w Al 44 w 21.PROVIDE"AS BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION." STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP"AS-BUILT" LWITH RED LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE 19.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. PEN. DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 20.DIFFUSERS: SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD STUDS AT CORNERS,POSITIONEDTO R / LVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS TOP SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BU ILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND BOTTOM TRACKS BY WELLDINDING OR SCSCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG a. TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. '. AND APPROVED. TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE- 22.1T IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, THE PROJECT. DESIGN TITUS 350; EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED a TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH) c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST WHETHER OR NOT SHOWN ON THE DRAWINGS. WITH 114"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. "Y"BRANCH. 'l� 23.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"ICES.". 6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT W 24."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 7. FINISH QUALITY: COMPLETION. CARMAN Rd. a PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 21.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE EXIT #291 1 AREA PROCESS TRADE NOMENCLATURE HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. 11 V��RS C 25.D0 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. WAREHOUSE TAPE/FINISH COAT* TIGHT DOUBLE APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY �} 26.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN OFFICE/OTHER AREAS TAPE12 FINISH COATS'1 SMOOTH FINISH TAPED PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY ATE C g a TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS). CONTRACTOR SHALL PROGRAM •J REPLACEMENT AT CONTRACTOR COST. AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL USG"FIRST COAT" *SAND AFTER TAPE 1 FINISH COAT(S) THERMOSTATS AND BALANCE SYSTEM. REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS 22.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. L CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS , r O r DIRECTED AT CONTRACTOR'S COST, SHOWN ON PLANS. 23.WAREHOUSE HEAT: iDt in 27.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND 09 53 00 SUSPENDED ACOUSTICAL CEILING a. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE `f'!y PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. ENERGY CODE REQUIREMENTS. PROVIDE ADJUSTABLE T-STAT FOR EACH UNIT. BUILDING MIN, 0 7) SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE 2. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. 24.EXHAUST FANS: LOCATION , °,•=, •;y: COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. -P • 111 Qrr r.zCEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT 28.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS 3. BENT OR DAMAGED T-BARS TO BE REPLACED. a. Al.\ �BCODE REQUIREMENTS INCLUDING INTEGRAL BACK❑RAFT DAMPER AND VENTING TO THE EXTERIOR. CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A �, Ae5, & A . LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE ACCEPTABLE. SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE 09 68 00 CARPETING b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING �A 0,4 a CENTERED IN CEILING TILE(OR 2 x 2 MODULEOF A SECOND LOOK II TYPE OF CEILING TILE WHERE ,Ay APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY 1, USE MANUFACTURERS APPROVED ADHESIVES. MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. -P,THE ARCHITECT PRIOR TO INSTALLATION. c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE 29.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE 09 91 23 PAINTING ROOFTOP MOUNTED EXHAUST FAN, FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. INTERIOR: CONTROLS AS REQUIRED BY DESIGN.COOK ACE-D SERIES OR EQUAL. 14 GENERAL 1. WALLS: d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC. IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. ROOFTOP MOUNTED FAN. TO INSTALLATION OF NEW FLOORING. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 25.HVAC TESTING. 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL.A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 2. DOORS AND FRAMES: a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, re T 1 POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH V 07 00 00 THERMAL&MOISTURE PROTECTION a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. APPROVED PLANS AND SPECIFICATIONS. b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN iTh LOCATION MAP I T 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. Ze 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND �A=l_i NOT TO SCALE 4.11 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, FILED WITH PACTRUST. AND FINISH WITH SATIN OIL ENAMEL. 26.PROJECT CLOSE OUT DOCUMENTS REQUIRED: �^/� 08 10 00 DOORS AND WINDOWS d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. CA 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. 3. CEILINGS: b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. • 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO 1} 2 C3) 97) L1 (7) Iia 1 riII a. BAXTER AND FLAMING. (503)225-0486 ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. c. HARD COPY OF AutoCAD FILE ABOVE. T � T T T T d. OPERATIONS MANUALS FOR ALL EQUIPMENT, INCLUDING T-STATS. b. D&D DOOR (503)205-5533 b. NEW GYP BOARD 1 PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE 110 c. GRANT SUPPLY (360)887-0647 WITH MILLER'S 6200 OR 4480. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. I I 26 00 00 ELECTRICAL : DESIGN/BUILD GENERAL NOTES: 3. DOOR AND RELITE FRAMES SHALL BE TIMELY,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING 4. MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER GENERAL I I I I I I /ti GY 4. EXTERIOR DOORS AND FRAMES TO BE HOLLOW METAL. FRAMES OF ONE-PIECE WELDED CONSTRUCTION, SPRAY' 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR g:-- .--- } - t( 14-GA.GALV.SHEET STEEL. DOORS,SDI-100,GRADE II,SEAMLESS EDGES, 16 GA.GALV.SHEET STEEL. b. ALL SURFACES TO BE SANDED BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. I T . I I I I ,�--_, FABRICATE DOORS AND FRAMES WITH HARDWARE REINFORCING WELDED IN PLACE. c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING ` i i I C/] in 5. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, RAGS AT THE END OF EACH DAY. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. ' I ! i nml - I o FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. It d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. ., 6. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. AND SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. kw I7tmi t� O o\ 3. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. # �. 7. DOOR HARDWARE SHALL.BE SCHLAGE Al..SATURN OR D RHODES SERIES U.N.O. e. PROTECT WORK OF OTHER TRADES. t/] O O 4. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. METER �� I j I i I 8. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. f. PROVIDE"WET PAINT'SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO I TENANTS MOVE-IN. 1 / i IA .- 9. AT INTERIOR DOUBLE DOORS PROVIDE TOP AND BOTTOM FLUSH BOLTS AT INACTIVE LEAF. TOP BOLT TO 10 00 00 SPECIALTIES (1 -----.-- �-HAVE EXTENSION BOLT. 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO I r:Li r21 10 44 16 FIRE EXTINGUISHERS 1-FOOT CANDLE. I 10.DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR IAPPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. WITH BATTERY BACKUP. _ _ iOSHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS7. WHERE NEEDED, CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE - ����� i�-1--. W PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THt APPROVED CONTROL 12 00 00 FURNISHINGS 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. �� �� r� U T71 0 VD SAMPLE. 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. < 11.ALL INTERIOR GLAZING SHALL BE TEMPERED. a. TRANSFORMERS TO BE ENERGY STAR LABELED. p„i \� 2. 0 INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. AREA OF WORK `i 12.DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE 23 00 00 HVAC : DESIGN/BUILD CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C n WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. GAS METER TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS REVISION 13.PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFL TAPS. MAXIMUM 2 BUILDING PLAN SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL FINISH FOR AS NEW LOOK. METER IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR ASSEMBLY AND CASE. 1"= z 14.TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. TO TENANTS MOVE-1N. A-1 SCALE 40 1. HVAC-BID PROCEDURE 9. FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCESS BELOW FLOOR,USE WIREMOLD RC7 15.OVERHEAD DOORS;WAYNE DALTON THERMOSPAN 125,EXTERIOR WHITEISTUCCO. FLUSH STEEL INSULATED, FLUSH POKE-THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE WIREMOLD RFB43-OG, 2"THICK;STANDARD LIFT OPERATING STYLE WITH TRACK AND HARDWARE. OPERATION;PULL ROPE FOR 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN PROVIDE 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. 2. DOORS TO 10'TALL,CHAIN HOIST FOR TALLER DOORS. PROPER WORKING ORDER. 10.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. OFFICE COPY 3. 16.TUNE UP EXISTING OVERHEAD DOORS FOR SMOOTH OPERATION. WORK INCLUDES: 2. INVENTORY EXISTING H.V.A.C. ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH 11.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. v a. ADJUST OVERHEAD SPRING TENSION TO MEET MANUFACTURER'S SPECIFICATIONS. UNIT •b. REPLACE TOP AND BOTTOM DOOR SEALS AS NEEDED. 3. LIST TONNAGE OF EACH UNIT. 12.00CUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. 4 CITY OF TIGARD HVAC-DESIGN PROCEDURE 13.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS, EQUIPMENT 5. c. REPLACE BENT TRACKS AND PANEL SECTIONS. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND REVIEWED FOR CODE COMPLIANCE d. REPLACE ROLLERS AND HINGES AS NEEDED. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE LISTED BELOW. IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. Approved:\�I IstA ^� 6. e. REPLACE ROPES AS NEEDED. PRIOR TO AWARD OF CONSTRUCTION CONTRACT, H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR 14.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. `E ] i [--�� 1�� �` 7. f. LUBRICATE ROLLERS REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH OTC: ila��-" J NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. 15.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA J1 09 00 00 FINISHES INCLUDE THE FOLLOWING: BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. Permit# ~1(,LY g01.7---e.,00/17 S. . GENERAL 16.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE -7 n�, b. DUCTING AND SIZES DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION ��� �ts�'' G 8� sw _L �'P � �o 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. C. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL.OR DIFUSER OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING . ' �! g SLi11C #: 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: d. ROOF EQUIPMENT,SIZES AND LOCATIONS OFFICE LIGHTING a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS e. UNITS REQUIRING DUCTED SMOKE DETECTION 1. GROUP RE-LAMP EXISTING FLUORESCENT LIGHTS THROUGHOUT U.N.O. By: � ) Date: _ ,_-1..- J. R.M.T. b. PLASTIC LAMINATES f. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH 2. OFFICE LIGHT FIXTURES-LITHONIA 2ES8P F 232 MVOLT ADVANCE OR EQUAL. (NO SYLVANIA BALLASTS) ! c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) g. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 3. REST ROOM-WALL MOUNTED LIGHT FIXTURE- PEERLESS CERRA WALL LED,CRW7L HI 4FT R4 120 EZB LP840 DATE: 2/21/17 ' d. PAINT C210SCEP,3500K. Approved plans h. ZONE DIAGRAM shall be on PERMIT/BID SET e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS HVAC DESIGN STANDARDS 4. RECESSED LED DOWN LIGHT: LITHONIA LDN6 35/10 LO6 AR LD 277 TRWjob site. f. TOILET PARTITIONS THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: 5. OFFICE EGRESS LIGHTING: !SOLITE MINI GENIE SERIES LED VERSION LM1GN NM SQ-CEILING AND WALL g. HARDWARE MOUNT. SEE PLAN FOR EGRESS PATH.USE OF'SOLITE INVERTER AS ALTERNATE TO BATTERY IS 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). ACCEPTABLE. 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY 6, LIGHT SWITCHES:ACUITY CONTROLS WSX D DIMMING OCCUPANCY WALL SWITCH. PRE SET ALL PRIVATE 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET TENANT PRIOR TO CONSTRUCTION: OFFICE AND CONFERENCE ROOM SWITCHES TO'VACANCY"AND TO TURN ON AT LAST DIM LEVEL. 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TELE(EXCEPT AT BULLNOSED EDGE)OF TILE a. EXTERIOR EXPOSURE AREAS WAREHOUSE LIGHTING (CERAMIC,QUARRY OR PORCELAIN) b. INTERIOR AREAS,SIZE AND USE 1. LITHONIA SIX LAMP,IBZ-654L MVOLT ADVANCE,54W,T5HO FLUORESCENT 277V.LIGHT LEVEL 10 TO 15 FC AT CITY OF TIGARD 09 21 00 GYPSUM BOARD 30"A.F.F A - i c. CONFERENCE/TRAINING ROOMS GENERAL 2. LITHONIA LIGHTING ELM654-2006 EGRESS LIGHTING. A rope ray Planning d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION PP 4. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. Date: 2� L Initials: O3082 �� ll 3082 W• . HANSON '� i rr0 t� CLA KAM\S, OREGON,. �6'''�'-.�-- - 45' O 4� �I--�� . 66 -05.--v-ut 45 -13i r WOMEN MEN '. OF O1 �l� 103 102 , STORAGE/IT 41` � (g 1 N BREAK/WORK W 17 �e� v 5-5v e-F 101 PROJECT #17060 Iv I ;� 104 1�1 GPT t X15 'G GONG. I� �.` i 1 45' s I Fl iI 45' I tt �♦ r 1 II i I U 4,q,1 II 1 1 h •d 45' • I' , II \ 145 1 ! I \ II I �___� ll Al ID ID -- – rt ' 11 6 xxxxxx ADJUST FRAMED HEAD ( 11 v HEIGHT AND INSTALL W I '1 RELOCATED DOOR AND Tr-F4,5 �1'.j I �iT FRAME p. �'I IST I 11 RELOCATED DOOR �, 11 r I 1 AND FRAME ,-14,5 iI t 20 GA 3 518'METAL STUD BRACING TO ROOF rr � --- if IT i`I I 1 , /'J II ► C' STRUCTURE ABOVE FOR WALLSSTRUCTURE AT loco' OC TO LONGER THAN 1.I 3 �� 1 ,�� 1 `��` __•fir It I ► a UUILDING ► 12'-0' WITHOUT INTERSECTION WALLS. FASTEN ,---ii 11 =+ ID Q'' ► u 0 C ) OPEN OFFICE / EACH END WITH(!1'S SHEET METAL SCREW i a,• I I § 100 �---jOr ti '� 1 i11 1 1 _.,,m. / C 4 ,� , R-11 BATT INSULATION 4' CENTERED OYER WALL il_.= � , X �° c , 1111 , E+1111111, v: .jea. : f .r SUSPENDED CEILING 0 WERAHOUSE 'Oil 1 105 BLOCKING TYPICAL AT FASTENNG POINTS 1 q .:. x+ _ j� ► 3 112 BATT INSUL. w N t_=_JJ I 4 4 3 1/2'MIL.STUDS 24'O.G. g OfNREMODELSSIZESTUDSTOALLOW REUSE% I 8 _ LL_=-� 1131 OFBLDG.STD.DOORSANDFRAMES O n i ._T5113'GYP.BRD.BOTH SIDES Z _ -6 - K� Iti== rr�' x fir CENTER LINE OF STUD I—1 cw/1 CA N 1 1 ‘,.• T 4- F \D H i C j CA M M 11 _ ,, ► WOG GPT O 1�In . 6 . hil ° zx mgr 7 n i Qr" 0 i 7 _ (� !-�� 4' RUBBER BASE TYP. ,�a R i w �� ATTACH !BOTTOM TRACK TO FLOOR WITH Vil _ ��; POWDER DRIVEN ANCHORS AT 12'0.C. 1.40, 111111r FINISH FLOOR •Iia1- r 1 DEMO PLAN 2 PARTITION AND POWER PLAN Z 5 WALL SECTION WITH SOUND INS. a ED A-2 SCALE 1/8"= 1'-0" A'2 SCALE 1/8" = 1'-0" A-2 SCALE 1" = 1'-0" W ., a 0 D 0 A II [-- a . . / 1- L__:____ . NEN I . - .or :2: : ,w, O - ai /< / — l r - _€_ >< -/< X= \ llic A. 1 1; lel AI I _= 0. . Elk L—I A } I. r_ ,�„11�IIPIi�`° I—IN 11 # ► ► ulVlll liva/ 01 T Q -J--1--L_J--1--t--J--+-_L I 1 I 1 I 1 1 1I0,AI ,___ IL 1 1 I I I I 1 1 1 I /' a --1--+rte=6-".i--+--IIr7�="4- F- i �/� l��/�l y . - , R _ iii><I IA 11 RM �_ 1 _w 13 -4-- 7.-/-: 1 --lict.--4------11F--- • k I'4 ) Crir) I I I I 1 1 1 I I 11/ \11 I W. I /� _ 1 I I I 1 i I \ FA> \\ 1_1><, i W 1 - PI-1 �'–ic- --T--I--T-- = 1-1'lll--r1 �R ' IV�rtll 1 I I 1 I 1 I I 1 1 �� _11411_1al==1--L--I___L_�--.......I_- LJ I -6 1 '`'.` - 1 1 I 1 1 1 I _ 1, 1 --_ I I I I 1 /{� I I I i �� i I R >< [ I Ei ' - I I t I I 1 I 1 I I 1 1 = 00 - I I 1 1 1 1 1 1 I I ii I I I I [ 1 I 1 I 1 I I _ _ -�-- \.a-- +r g\{ ,.;yl __ E - - Win] I ->�� ,, .� f14- SII ..III®. I 1 A>. _ .A' ^ W -7--T-=alao7--I-----�-'I -I--7--T-1 �� / , 1 1 I I I 1 1 _ 1 I 1 I E 11 I I d�� I I I I I I l 1 `, 'r4I COD itcr.:3' -�- – � 1 It,->C� I \�Il 0 ON a - 1--T=sr--'I--7" I h c p 1 7 _ . ,..: -ix l''4g l - - IV-1- n n •-c 1 ^-....• r� tnaC7 3 1 CEILING DEMO PLAN z 4 CEILING PLAN Z ED o o o A- cn 2 SCALE 1/8"= 1'-0" A-2 SCALE 118"= 1'-0" U Q 0 `D CONSTRUCTION LEGEND cani N o krl EXISTING TO REMAIN EXISTING TO BE REMOVED REVISION NEW STANDARD WALL ' 1. -8 DUPLEX RECEPTACLE e ELECTRICAL PANEL 2. ABBREVIATIONS FINISH MATERIALS ?;i FOURPLEX RECEPTACLE 0 POWER !-BOX 3_ (FOAM) (2016) BRK BRICK PAVERS ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. CP-# CUT PILE CARPET ° DEDICATED OUTLET Q ® FLUSH MOUNT FLOOR MONUMENT WI POWER AND DATA 4. CARPET LOOP PILE: CR CHAIR RAIL LP-1 MOHAWK GROUP CROSS KNIT BC375150375-358 RESHAPED FELT,DIRECT GLUE E EXISTING 07 EXISTING ELECTRICAL TO REMAIN ID FIRE EXTINGUISHER IN RECESSED CAB. 5. USE MOHAWK BRAND NUBROADLOK PREMIUM ADHESIVE ONLY ETR EXTEND TO ROOF WALK-OFF CARPET TILE: FWC FABRIC WALL COVERING / FLOOR MONUMENT W/SERVICES SHOWN ® FIRE EXTINGUISHER SURFACE MOUNTED 6. WOC MOHAWK GROUP TUFF STUFF II-STEP UP II-983 IRON ORE,DIRECT GLUE GT GROUT SPECIAL OUTLET Qr THERMOSTAT USE MOHAWK M700 ADHESIVE. (M95.0 IN HIGH MOISTURE AREAS) HM HOLLOW METAL 7. BASE PGWB PAINTED GYPSUM WALL BOARD 4 TELIDATA MUD RING WITH PULL STRING $. RF FLEXCO 4"FLAT RUBBER BASE,071 BLACK I BROWN,AT ALL CARPET AREAS. PL-# PLASTIC LAMI NATE RC FLEXCO 4"COVE RUBBER BASE,071 BLACK!BROWN,AT ALL HARD SURFACES. PLW PLASTIC LAMINATE WAINSCOT �v PAINT: POT PORCELAIN TILE CEILING LEGEND P7 1 MILLER 110-4 ACRO PURE ULTRA-LOW VOC 0017 LUNA MOON,SATIN LATEX. POTW PORCELAIN TILE WAINSCOT (AT ALL RESTROOMS USE MILLER 320-4 ACRINAMEL PT-# PAINT R.M.T. PT-3 MILLER 8180 PERFORMANCE FLAT-MIX IXX79W(WAREHOUSE WALLS) RC RUBBER BASE COVED \/ 2 X 4 FLUOR.T-8 3 TUBE FIXTURE SUPPLY DIFFUSER RF RUBBER BASE FLAT /\ PARABOLIC LENS(DZ INDICATES DAYLIGHT ZONE) DATE: 2/21/17 TOILET PARTITION COLOR: SAT SUSPENDED ACOUSTICAL TILERETURN DUCT 7� HADRIAN POWDER COATED-837 BLACK FOX SC SEALED CONCRETE lW 2 X 4 FLUOR.FIXTURE PERMIT/BID SET DOORS,HARDWARE AND FRAMES SV SHEET VINYL �iilllle.. PARABOLIC LENS/STEADY BURN BALLIST ® EXHAUST FAN • HARDWARE 625 POLISHED CHROME VCT VINYL COMPOSITION TILE f 1 6 TUBE T-5 FLUORESCENT FIXTURE a EXIT SIGN(LED RED) • FRAMES SMOKE WHITE WBC WALL BOARD CEILING .1 i OCCUPANCY SENSOR ON EACH FIXTURE WCG WALL CORNER GUARD WD WOOD RECESSED LED DOWN LIGHT(TYP.) WOC WALK OFF CARPET WW WINDOW WALL STANDARD SWITCH ® OCCUPANCY SWITCH A_ 2 . CEILING OCCUPANCY SENSOR