Plans (4) BU P2016 - 00332 HEALTHY LIVING Tim L rS ARCHITECTS 720 NW Davis 503.221.1121 M Suite 300 503 221.2077 It Portland OR 97209 www.Irsarchitects.com FANN0 CREEK PLACE ., BLDG. ,40As 16083 SW UPPER BOONES FERRY RD. . SUITE 100 1....C.=MT y. P14•4144 Otil--°.3 • TIGARD, OR 97224 Pow,OREGON * OF Ce PERMIT SET 11N29N2016 CONSULTANT: PROJECT DIRECTORY PROJECT SUMMARY CODE SUMMARY (SEE EGRESS PLAN BELOW) LEGEND (SEE EGRESS PLAN BELOW) BUILDING OWNER: I. GENERAL INFORMATION: V. ADA ACCESSIBILITY UPGRADES: 7. SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR REQUIRED EXITS PER SECTION 1015 E7Z1 AREA OF WORK Parkland Development LLC Su Moran:Su@pldus.com THAT PROJECT OCCURS,AND PROVIDE NOT LESS PROJECT NAME: HEALTHY LIVING TI. 1. BUILDING HAS BEEN UPGRADED ACCORDING TO THAN ONE APPROVED FIRE EXTINGUISHER WITH OCCUPANCY SPRINKLERED REQUIRED PROPOSED — — — — 44"MIN. EXIT EGRESS PATH 16083 SW Upper Boones Ferry Road PROJECT ADDRESS: 16083 SW UPPER BOONES THE ACCESSIBILITY UPGRADES LIST AS OUTLINED RATING OF NOT LESS THAN 2A 10B/C FOR EACH Suite 120 FERRY RD. IN OSSC 3411. 1,500 S.F. OF FLOOR AREA OR FRACTION B Y 1 1 B OCCUPANCY GROUP Tigard,OR 97224 SUITE 100 THEREOF. TRAVEL DISTANCE TO AN TIGARD, OR 97224 EXTINGUISHER FROM ANY PORTION OF THE X ROOM OCCUPANT LOAD PER SECTION 1004 Telephone (503)639-0108 MAP/TAX LOT: W248495 VI. EMERGENCY SYSTEM STANDARDS: BUILDING SHALL NOT EXCEED 75 FEET PROVIDE EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER (XX) ACCUMULATIVE OCCUPANT LOAD FIRE EXTINGUISHER IN ACCORDANCE WITH TABLE 1016.2 PROPERTY MANAGER: IL APPLICABLE CODES: 1. BUILDING IS FULLY SPRINKLERED(NFPA 13). CURRENT CODES. PROVIDE NEW FIRE U0 UNOCCUPIED SPACE Colliers International Monique Clouser:Monique.Clouser@colliers.com MAKE CODE MINIMUM CORRECTIONS AS EXTINGUISHER AT ALL EXISTING CABINETS OCCUPANCY SPRINKLERED REQUIRED PROPOSED 851 SW Sixth Ave. 2012 INTERNATIONAL BUILDING CODE(IBC) REQUIRED PER NEW PLAN. WHERE MISSING. ALL REUSED EXISTING FIRE EXIT SIGN w/INTEGRATED DIRECTIONAL ARROW Suite 1200 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC) 2. IN BUILDINGS WITH EXISTING SMOKE DETECTORS: EXTINGUISHERS ARE TO BE INSPECTED AND/OR B Y 300'MAX 106'-6" ® ®a 2014 OREGON MECHANICAL SPECIALTY CODE(OMSC) PROVIDE CODE MINIMUM CORRECTIONS AS RECHARGED,AS NECESSARY,JUST PRIOR TO WHERE OCCURS AT ALL EXITS, EVERY 100'IN Portland,OR 97204 2014 OREGON FIRE CODESUBSTANTIAL COMPLETION. CORRIDORS,AND IN SPACES WHERE 2 MODES OF REQUIRED. SMOKE DETECTORS TO BE TIED TO EGRESS ARE REQUIRED PER SECTION 1011. (REFER Telephone (503)684-6000 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE THE BUILDING ALARM SYSTEM. (OEESC) TO ELECTRICAL DRAWINGS FOR MORE 2014 OREGON PLUMBING SPECIALTY CODE(OPSC) 3. IN BUILDINGS EQUIPPED WITH AN EXISTING INFORMATION). POCHE INDICATES EXIT"TEXT SIDE ARCHITECT: 2014 OREGON ELECTRICAL SPECIALTY CODE(OESC) VISUAL STROBE SYSTEM:PROVIDE CODE OF SIGN. SIGNS SHOWN IN CORRIDORS ARE LRS Architects, Inc. Michelle Start mstartt@Irsarchitects.com IN COMPLIANCE WITH WITH OEESC. MINIMUM CORRECTIONS AS REQUIRED. IFA CEILING HUNG. SIGNS SHOWN ON WALL ARE WALL 720 NW Davis,Suite 300 Darcie McConnaha:dmcconnaha@lrsarchitects.com SYSTEM DOES NOT EXIST,DO NOT ADD ONE. HUNG. Portland,Or on 97209 IV. BUILDING STANDARDS: 4. PROVIDE EMERGENCY EGRESS LIGHTING FOR THE EGRESS PATH IN ALL PUBLIC AND TENANT E REQUIRED EXIT Telephone(503)221-1121 BUILDING TYPE: TYPE II-B(SPRINKLERED) SPACES. MINIMUM INTENSITY SHALL NOT BE LESS BUILDING OCCUPANCY: B(PROFESSIONAL THAN 1 FOOTCANDLE AT FLOOR LEVEL ALONG GENERAL CONTRACTOR: SERVICES) THE ENTIRE LENGTH OF THE PATH. CONNECT TO TOTAL BUILDING FLOOR RENTABLE AREA: +1-49,963 BUILDING ELECTRICAL SYSTEM. Built Environment Northwest Roman Michalchuk:RomanM@BE-nw.com S.F. 5. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE 135 East Hereford Street CONNECTED TO BUILDING POWER SUPPLY WITH PO Box 160 AREA OF WORK: BATTERY BACK-UP FOR MIN 1-1/2 HOUR Gladstone,OR 97027 TENANT AREA: +/-3,383 R.S.F. DURATION. PROJECT NUMBER: 216248 TOTAL TENANT OCCUPANT LOAD:42 MAX. OCC. LOAD Telephone(503)650-4086 6. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS AS REQUIRED. Healthy Living DRAWING INDEX Tenant SHEET NAME Improvement A001 COVER SHEET A100 GENERAL NOTES&STANDARD MOUNTING HEIGHTS Fanno Creek Place A201 CONSTRUCTION PLANS Building B EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER TABLE 1016.2; 16083 SW Upper Boones ALLOWED DISTANCE 300'MAX.LENGTH(SPRINKLERS PROVIDED) Ferry Road DEFERRED SUBMITTALS - DESIGN BUILD ACTUAL DISTANCE=106'-6" GENERAL NOTES F—... -- On Suite 100 MECHANICAL SYSTEMS EXIT ILLUMINATION THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE ONLY. SEE ALL OTHER PLAN SHEETS FOR CONTRACT DOCUMENT o I Q[ It��97224 ELECTRICAL SYSTEMS LOW VOLTAGE SYSTEMS INFORMATION. THE PROJECT SUMMARY IDENTIFIES SOME SPECIFIC OSSC REQUIREMENTS BUT IS NOT INTENDED TO LIST ALL OSSC ''-^_– REVIEWEDtia FOR COMB CQA1P` ANC REQUIREMENTS. r� B I Appy _ f t, t ,� c1oc9 t 4 • AI* IV OCCUPANCY }�Ci ire;d BUILDING "' r7 I 33- -i, , ,` % *t* Iii UILDI A e�� r.!� +) eltYll t t • �p[v t±tS� �r� �--i m 1 ( kw. .41 +�� '�►�'*' �7 r iJr+ r'Li _ r* �'� 1llifl '. i _ ; a ''�}°a �. • *Iie �'� I ( ..... " Suite#itn �� J� ,�p e ,. H rring ♦ ,#% + Al OCCUPANCY ~• sr I I $ 1►�. '4 1 *.‘. , -,,,. i i 4111%,„; iiii V 1,, ..w- \ ; si# \ 1:13 - ' - IZI‘ ,!"4P4 ..,....ar a,.. p-Neck . ‘ . . 4.... ....., .„.,,,,, . , ._-,..\ , , 0 0 ,i . -1 - > - * SAW �ia��7�� ►t 47:41#y• am+. �; �r t►s I / B a ,e , ir S'i4 l' 4 St `a m .y 5; y 7i: Welt' *i ilii#r !�l► '.�1� C�r i T9 �1 1 � hi .':r.�s�:� {y� �Wj f €OCCUPANCY �. �II.E COPY z-, �� _.- • .r -.f BLDG. .=.IC= I dElai E4.1 Alder in k? %►� ��V; n�1'a��`/' 7a1 s'.�s // `■ - , — — * s ' : ? *4 ft „- ffu . ",►',--:,..5., , gli.),, 9 s si: 7?� �i �► s�`1 �* ( �■ op I is=�' ► SHEET TITLE: iG •!;f r r, e e'6 'Aero ,0`4PAe BUILDING — {w Ave �tSr� '� ������ Ir__I/ !:I I , I ; A .e. 4-.�: I Cover Sheet R r I l / AO _ �Ei ' �'�•► ri► , , �.r■I��i� II ' 1 I vc° r : ; ,� 111111 sir , I -11111 $_ ,„. Durham ,3 . •\ON+•/14° sr �r� i P* _ el.° T'l ‘ \\\ \ ll: �� ._tip \ \- •��,.' '' '� rV plAr ',► s / - - J `L"J 1� 'his 1 �1t -- / \\ .... � .�j! A ,'��4� / S I' �� �* /0� �jl�' I ir . II A EM l! a i * w \ Jiv. /1 �.�i �l♦ fir,.• t,' • 41,41 ' ier- �' ,' , ' 1 I l:. ....V._ •. \ \\ ��' r��! ter. ,� �,:•I / �� S-1 - I OCCUPANCY x i I ` l \ \7►4 {:ti i�lo 4,0 '��< / %) OCCUPANCY . I DRAWN BY: PMK di x \\ '� i - - DATE ISSUED: 11.29.2016 i x \ `�►y ! moi► _ ��_ � s� 4 , aa j I , Air-44 „i p b `f"" :r �, ,+(' r,'?.` > .. rt '�` - ». \ \`"- / {- ik AN "To - I _ --------- -- _ .. a /—_�. �II =_ I -- AiG . co N \\.\ N ..„,./ il + AREA OF WORK SPACE WITH ONE MEANS OF EGRESS PER TABLE 1015.1; 8 MAX OCCUPANT LOAD ALLOWED:49;ACTUAL LOAD=42 1. VICINITY MAP 2. SITE PLAN 3. SUITE LOCATION AND EGRESS PLAN ® A001 SCALE: NOT TO SCALE SCALE: NOT TO SCALE SCALE: 1/16"= 1'-0” a • 2 0 SHEET: z n LRS Architects,Inc.)2016 E m PERMIT SET 11.29. 16 E Z 0. GENERAL NOTES LrwS GENERAL 23. NEW DOOR HARDWARE SHALL MATCH EXISTING BUILDING STANDARD LEVER HANDLE WITH PRIOR TO ACCEPTANCE OF BID. EXISTING SYSTEM SERVES AN OCCUPANT LOAD OF A 100 OR MORE AS REQUIRED BY CODE. FINISH TO MATCH BUILDING STANDARD. FINISH OF HINGES AND CLOSERS TO MATCH. ALL 46. DESIGN-BUILD CONTRACTOR TO PROVIDE CERTIFICATION THAT OUTDOOR AIR MATCH EXISTING BUILDING STANDARD WHERE POSSIBLE FOR REQUIRED EMERGENCY 1. THE GENERAL NOTES ARE INTENDED TO CONVEY DESIGN INTENT NOT OTHERWISE STATED IN HARDWARE SHALL BE ADA ACCESSIBLE. REQUIREMENTS OF CURRENT CODES WILL BE MET FOR EACH OCCUPANCY USE WITHIN THE SYSTEMS AND INSTALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT ARCHITECTS THE DRAWINGS AND SPECIFICATIONS. THE PROJECT INTENT IS TO PROVIDE A COMPLETE 24. CONTRACTOR SHALL VERIFY COMPATIBILITY OF HARDWARE SPECIFIED WITH BUILDING TENANT IMPROVEMENT AREA. NATIONAL ELECTRICAL CODE. WORKING TENANT OR BUILDING IMPROVEMENT. KEYING SYSTEM. 47. INTERIOR AND PERIMETER OFFICES SHALL NEVER BE ON THE SAME ZONE. CONFERENCE 69. PROVIDE VISUAL AND AUDIBLE ALARM SIGNAL APPLIANCES INTEGRATED INTO THE BUILDING 720 NW Davis 503.221.1121 M 2. ALL WORK SHALL CONFORM TO THE 2012 INTERNATIONAL BUILDING CODE(IBC), 2014 25. PROVIDE NEW DOORS MATCHING EXISTING DOORS'VENEER SLICING PATTERN AND GRAIN ROOMS AND LUNCHROOMS CAPABLE OF SEATING (6) OR MORE SHALL ALWAYS BE ON THEIR ALARM SYSTEM AS REQUIRED BY ADA AND CURRENT OSSSC STANDARDS. PROVIDE OREGON STRUCTURAL SPECIALTY CODE(OSSC), 2014 OREGON MECHANICAL SPECIALTY DENSITY,AND FINISH. OWN ZONE. ADDITIONAL ELECTRICAL SERVICE AS REQUIRED. COORDINATE REQUIREMENTS WITH Suite 300 503 221.2077 0 CODE(OMSC), 2014 OREGON FIRE CODE, 2014 OREGON ENERGY EFFICIENCY SPECIALTY 26. PROVIDE CLOSERS ON ALL TENANT ENTRY OR EXIT DOORS TO MATCH EXISTING BUILDING 48. DESIGN-BUILD CONTRACTOR SHALL VERIFY THE SUITABILITY AND CONDITION OF SCHEDULED BUILDING OWNER. ALARM LOCATIONS INDICATED ON PLANS ARE ONLY FOR REFERENCE. CODE(OEESC), 2014 OREGON PLUMBING SPECIALTY CODE(OPSC), 2014 OREGON ELECTRICAL STANDARD FINISH AND TYPE. EQUIPMENT TO BE RE-USED OR RELOCATED. DETERMINE ITEMS THAT NEED TO BE 70. PROVIDE SHOP DRAWINGS FOR ALARM SYSTEM LAYOUT AS REQUIRED BY CODE. Portland OR 97209 www.lrsarchitects.com SPECIALTY CODE(OESC)AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING 27. PROVIDE DOOR OPENINGS IN RATED WALLS COMPLYING WITH REQUIRED SMOKE CONTROL REPAIRED OR REPLACED. PRICE THESE ITEMS SEPARATELY AND AS EXCEPTIONS/ 71. VERIFY SERVICEABILITY AND REUSABILITY OF EXISTING ELECTRICAL EQUIPMENT,AND AUTHORITIES. ASSEMBLY AND INDICA TED FIRE PROTECTION RATING OF NO LESS THAN 20 MINUTES. CLARIFICATIONS IN BID. REPAIR OR REPLACE AS NECESSARY. 3. CAREFULLY EXAMINE THE PROJECT SITE AND CONSTRUCTION DOCUMENTS. VERIFY ALL WHERE EXISTING DOOR OPENINGS DO NOT COMPLY WITH PRESENT BUILDING CODE 49. AUTOMATIC SPRINKLER SYSTEM SUPERVISION: ALL VALVES, INCLUDING THOSE IN PITS, 72. VERIFY THE CAPACITY AND REUSABILITY OF EXISTING ELECTRICAL PANELS TO MEET DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK AND REPORT ANY DISCREPANCIES REQUIREMENTS, PROVIDE NEW DOORS, FRAMES AND HARDWARE THAT COMPLY. SHALL BE MONITORED BY UL LISTED FIRE MARSHAL-APPROVED CENTRAL STATION. WATER PROJECT REQUIREMENTS. TO THE ARCHITECT. 28. ADJUST THE RESISTIVE FORCE OF ALL NEW AND EXISTING INTERIOR DOOR CLOSERS IN THE FLOW AND HIGH/LOW PRESSURE FOR DRY PIPE SYSTEMS IF USED) SHALL BE SUPERVISED, 73. TERMINATE ALL CONDUITS IN STANDARD DUPLEX BOXES, UNLESS OTHERWISE INDICATED. 4. OBTAIN AND PAY FOR ALL PERMITS AND FEES TO COMPLETE THE WORK. OBTAIN AND PAY PROJECT AREA TO A MAXIMUM PRESSURE OF 5 LBS. TO COMPLY WITH ADA REQUIREMENTS. AS WELL AS OTHER FEATURES DEEMED NECESSARY BY CURRENT NATIONAL FIRE 74. KNOWN EXISTING (E)ELECTRICAL AND PHONE/DA TA OUTLETS HAVE BEEN INDICATED ON THE FOR ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED FOR PERMITS. PROTECTION ASSOCIATION STANDARDS. DRA WING. ADDITIONAL EXISTING OUTLETS MAY EXIST AND SHOULD BE VERIFIED BYcn4)°D 14 la 5. THE CONTRACTOR SHALL PROVIDE AND PAY FOR DUMPSTER AND TELEPHONE. FINISHES 50. PREPARE SPRINKLER SYSTEM SHOP DRAWINGS FOR COORDINATION WITH ARCHITECTS CONTRACTOR. 'M 6. COORDINATE ARCHITECTURAL WORK WITH MECHANICAL AND ELECTRICAL DESIGN BUILD DRAWINGS BY ARCHITECT. 75. VERIFY WITH TENANT OR OWNER LOCATIONS OF ELECTRICAL AND VOICE/DATA OUTLETS FOR t.-1' Z:WORK AND SUBMIT ALL DESIGN BUILD PLANS TO ARCHITECT FOR REVIEW PRIOR TO 29. REPAIR/REFINISH ANY DAMAGE TO EXISTING FINISH SURFACES IN IMPROVEMENT AREA 51. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES SYSTEMS FURNITURE PRIOR TO INSTALLATION. --03 CONSTRUCTION. CAUSED BY CONSTRUCTION OPERATIONS. NECESSARY TO COMPLETE THE WORK. 76. SMOKE DETECTION DEVICES INDICATED ON THE DRAWINGS ARE FOR REFERENCE ONLY. o �1 �' • 7. DIMENSIONS TAKE PRECEDENCE OVER SCALE. DIMENSIONS ARE TYPICALLY TO FACE OF 30. PAINT EXISTING WALLS WITH 2 COATS OF EGGSHELL FINISH PAINT UNLESS OTHERWISE 52. PROVIDE FIRE DAMPERS AS REQUIRED BY CURRENT OSSSC STANDARDS FOR NEW CONFIRM SPACING OF DETECTORS WITH DEVICE LISTING. ilk POR=TLAND,OREGON FINISH UNLESS OTHERWISE NOTED. NOTED. SUBMIT COLOR DRAW-DOWNS TO ARCHITECT AND OWNER FOR APPROVAL PRIOR TO CONFIGURATION OF FIRE-RATED PARTITIONS. 77. CLEAN AND REPAIR EXISTING SMOKE DETECTORS TO BE REUSED TO GOOD WORKING 8. KEEP PROJECT AREA OF WORK FREE OF GARBAGE AND DEBRIS ONA DAILY BASIS. APPLICATION. 53. BALANCE DESIGN-BUILD HVAC SYSTEM TO TENANT AND BUILDING OWNERS SATISFACTION. CONDITION. err 9. DO NOT DISTURB ADJACENT TENANTS BY NOISY CONSTRUCTION(i.e., JACK HAMMERING OR 31. WHERE ALL NEW PARTITIONS ABUT, JOIN OR CONNECT TO EXISTING SURFACES, WALLS, OR TOUR EXISTING CONDITIONS AND CONTACT OWNER FOR QUESTIONS PRIOR TO BID. 78. CLEAN NEW, EXISTING,AND RELOCATED LIGHT FIXTURES IN PROJECT AREA, OR IN AREAS OF 6' CORE DRILLING), OR ODORS(i.e., PAINTING OR ADHESIVE FROM FLOOR OR WALL NEW CONSTRUCTION, THE FINISHED SURFACE SHALL BE ALIGNED FLUSH. 54. INSTALL TEMPORARY FILTERS ON HVAC VAV BOXES AFFECTED BY WORK OF PROJECT PRIOR AFFECTED BY WORK OF THIS PROJECT,AT COMPLETION OF JOB. RELAMP AND REPLACE COVERINGS), SCHEDULE SUCH ACTIVITIES FOR AFTER NORMAL BUSINESS HOURS. 32. ALL NEW WALLS AND PARTITIONS SHALL HAVE TAPED JOINTS(3)COATS SANDED AND PRIMED TO CONSTRUCTION. REMOVE FILTERS AT COMPLETION OF THE PROJECT. BALLAST IN LIGHT FIXTURES AS REQUIRED TO RESTORE TO WORKING ORDER. COORDINATE SUCH ACTIVITIES WITH BUILDING OWNER. TO MEET PAINT READY REQUIREMENTS. 55. COORDINATE ZONE CONTROL OF EXISTING HVAC SYSTEM AT IMPROVEMENT AREA. 79. CLEAN AND REPAIR EXISTING EXIT SIGNS TO BE REUSED. REPLACE BATTERY AND/OR 10. STORAGE OUTSIDE OF BUILDING IS NOT ALLOWED WITHOUT AUTHORIZATION BY BUILDING 33. EXISTING WALLS AND SURFACES SHALL BE STRIPPED, RESURFACED,AND PATCHED AS SEPARATE AND REROUTE EXISTING DUCTWORK AND CONTROLS REQUIRED TO PROVIDE BALLAST IF NOT IN GOOD WORKING CONDITION. OWNER. REQUIRED. INDEPENDENT OPERATION BY TENANTS ON EACH SIDE OFA DEMISING WALL. 80. COORDINATE TELECOMMUNICATIONS AND MODIFICATION TO BUILDING ALARM SYSTEM 11. OWNER SHALL NOT BE RESPONSIBLE FOR TOOLS OR MATERIAL GOODS STOLEN OR 34. DISPOSE OF ALL PAINT MATERIALS OFF SITE. DO NOT POUR DOWN DRAINS, CATCH BASINS, 56. CLEAN ALL NEW AND EXISTING HVAC GRILLS AND DIFFUSERS SCHEDULED TO REMAIN. ALL PROVIDED BY TENANT. VERIFY WITH TENANT LOCATION OF NEW OUTLETS PRIOR TO CONSULTANT: DAMAGED ON SITE. OR IN LANDSCAPING. DUCTWORK BEHIND GRILLS SHALL BE A UNIFORM DARK COLOR. INSTALLATION. 12. CONTACT OWNER'S REPRESENTATIVE TO COORDINATE SCHEDULED ITEMS TO BE SALVAGED 35. PROVIDE A FULL GALLON OF EACH WALL COLOR WITH LABELS IN TENANT CLOSET OR UNDER 57. DESIGN-BUILD CONTRACTOR AT COMPLETION SHALL PREPARE AND SUBMIT AN AIR 81. REMOVE ALL UNUSED OR ABANDONED ELECTRICAL WIRING, EQUIPMENT,AND PHONE AND FOR RETURN. SINK, LABEL ALL LEFT OVER PAINT,AND DELIVER TO OWNER WHERE DIRECTED. BALANCING REPORT TO THE OWNER. DATA CABLING. CONFIRM WITH OWNER PRIOR TO REMOVAL.ALL WIRING AND CABLING TO 13. UPON COMPLETION OF WORK, BE RESPONSIBLE FOR RETURN TO OWNER OF ALL MASTER 36. TAPE AND SAND EXPOSED GYPSUM BOARD FOR A FLAT, SMOOTH SURFACE FINISH TO MATCH 58. HVAC CONTRACTOR TO PROVIDE 100%FRESH AIR SUPPLIED TO ENTIRE TENANT SPACE REMAIN SHALL BE SUSPENDED FROM STRUCTURE AS REQUIRED BY CURRENT CODE. KEY ORIGINALS OR CARD ACCESS DEVICES. EXISTING ADJACENT SURFACES IN BUILDING, UNLESS OTHERWISE INDICATED. THREE CALENDAR DAYS PRIOR TO THE FIRST DAY AFTER SUBSTANTIAL COMPLETION. 14. WARRANTY ALL PARTS, LABOR, EQUIPMENT,AND MATERIAL PROVIDED UNDER THIS 37. PROVIDE FINISH MATERIALS MATCHING ESTABLISHED BUILDING STANDARD QUALITY, UNLESS PROVIDE 100%FRESH AIR WITHOUT MAKING OTHER TENANTS UNCOMFORTABLE SCHEDULING OF FIRE SPRINKLER AND ALARM SYSTEMS CONTRACT OF A PERIOD OF ONE YEAR, UPON FINAL COMPLETION OF CONTRACT. OTHERWISE INDICATED. PROVIDE COLORS APPROVED BY OWNER AND ARCHITECT. 15. SUBMIT SUBSTITUTION REQUESTS ON CS!FORM TO ARCHITECT FOR APPROVAL. 38. CONTRACTOR TO FILL AND PATCH EXISTING CONCRETE SLABS AND SHALL PROVIDE SMOOTH ELECTRICAL-DESIGN BUILD 82. CONTACT OWNER'S REPRESENTATIVE FOR INSTRUCTIONS WHEN SCHEDULING WORK ON ARCHITECT'S DECISION IS FINAL WHETHER A PROPOSED PRODUCT IS ACCEPTABLE FOR UNIFORM SURFACE PRIOR TO NEW FLOOR COVERINGS TO BE INSTALLED. FIRE SPRINKLER&ALARM SYSTEMS. SUBSTITUTION. 59. ELECTRICAL SYSTEM AND REQUIREMENTS ARE DESIGN-BUILD. SUBMIT ELECTRICAL DESIGN 16. APPLICATION OF MATERIALS TO SURFACES EXISTING OR PROVIDED UNDER THIS CONTRACT FURNISHINGS TO ARCHITECT FOR COORDINATION WITH ARCHITECTS DRAWINGS PRIOR TO ACCESSIBLE FIXTURE MOUNTING REQUIREMENTS IMPLIES ACCEPTANCE AND SUITABILITY OF EXISTING CONDITIONS. CONSTRUCTION. 17. ALL WORK INDICATED ON DRAWINGS SHOULD BE CONSIDERED NEW UNLESS IDENTIFIED AS 39. INSTALL BUILDING STANDARD WINDOWCOVERINGS AT ALL PERIMETER WINDOWS IN 60. IF AN OVERRIDE SYSTEM EXISTS, PROVIDE EACH TENANT SPACE WITH AN OVERRIDE SWITCH 83. ALL DIMENSIONS INDICATED ON THIS SHEET ARE CLEAR MINIMUM TO FACE OF FINISH. EXISTING TO REMAIN OR TO BE REUSED. IMPROVEMENT AREA UNLESS OTHERWISE NOTED. DO NOT PROVIDE NEW IF ALREADY FOR FULL-SER VICE BUILDINGS. DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE CENTER LINE AS NOTED OR TO THE 18. ALL MATERIALS AND PRODUCTS USED ON THE JOB SITE SHALL BE"ENVIRONMENTALLY SAFE", EXISTING. REPAIR AND/OR REPLACE ANY DAMAGED WINDOWCOVERINGS TO MATCH 61. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES HIGHEST PORTION OF THE OPENING OR OPERATING DEVICE. LOW ODOR,AND NONFLAMMABLE. USE OF ANY PRODUCT NOT COMPLYING WITH THIS EXISTING. NECESSARY TO COMPLETE WORK. CRITERIA MUST BE APPROVED BY THE BUILDING OWNER. 40. FURNITURE INDICATED ON PLANS IS FOR REFERENCE ONLY AND SHALL BE CONSIDERED NOT 62. COORDINATE ITEMS REQUIRED FOR DEMOLITION NOT INDICATED ON DRAWINGS. 84. ALL ITEMS INDICATED BELOW MAY NOT OCCUR ON THIS PROJECT. SEE PROJECT PLANS AND 19. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGE OR CLEANING THROUGHOUT IN CONTRACT. 63. COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL SYSTEMS. ELEVATIONS FOR ITEMS THAT OCCUR. SEE ARCHITECTURAL PLANS FOR ACCESSIBILITY STRUCTURE DEEMED TO BE A RESULT OF HIS/HER WORK. THOROUGHLY CLEAN PREMISES 64. DESIGN-BUILD CONTRACTOR SHALL PREPARE A WRITTEN SCOPE OF ELECTRICAL WORK TO AND/OR ADAPTABILITY CONFORMANCE IN THE HORIZONTAL PLAN LAYOUT. UPON COMPLETION OF WORK, INCLUDING WASHING OF WINDOWS, SO THAT BUILDING IS BE PERFORMED TO THE OWNER WITH BID. READY FOR OCCUPANCY BY TENANT. INCLUDE CLEANING OF ADJACENT AREAS WITHIN AND MECHANICAL-DESIGN BUILD 65. ELECTRICAL LIGHTING ON DRAWINGS IS PROVIDED FOR REFERENCE ONLY AND IS INTENDED 85. CONFORMANCE TO FIXTURE MOUNTING HEIGHT REQUIREMENTS ARE APPLICABLE IN ANY AROUND THE BUILDING THAT ARE NOT PART OF TENANT IMPROVEMENTS, BUT WERE TO SHOW FIXTURE TYPES AND LOCATIONS. ELECTRICAL DESIGN IS BY DESIGN-BUILD PUBLIC AREA OR EMPLOYEE AREA MORE THAN 1000 SF,AS THEY OCCUR PER PROJECT. AFFECTED BY TENANT IMPROVEMENT CONSTRUCTION OPERATIONS. 41. MECHANICAL SYSTEM AND REQUIREMENTS ARE DESIGN-BUILD. SUBMIT PLANS AND CONTRACTOR IN ACCORDANCE WITH EXISTING BUILDING STANDARDS. COMPLY WITH 20. CONTRACTOR TO PROVIDE MECHANICAL AND ELECTRICAL AS-BUILT DRAWINGS,ALL SPECIFICATIONS TO ARCHITECT FOR COORDINATION WITH ARCHITECTS DRAWINGS, IN ENERGY CODE REQUIREMENTS AS REQUIRED BY CURRENT ENERGY CODES AND PROVIDE 86. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE WITH REQUIRED WARRANTIES AND OPERATING MANUALS TO BUILDING OWNER WITHIN TWO WEEKS OF ADDITION, CONTRACTOR SHALL PROVIDE WITH SUBMITTAL(2)COPIES OFA COLORED FLOOR ENERGY CALCULATIONS REQUIRED FOR WORK OF THIS PROJECT. MOUNTING HEIGHTS. COMPLETION OF WORK. CONTRACTOR ALSO IS TO PROVIDE FINAL CERTIFICATE OF PLAN DESIGNATING WHICH AREAS ARE CONTROLLED BY EACH THERMOSTAT. MECHANICAL 66. SWITCHING FOR LIGHTING IS INDICATED IN THE DRAWING FOR REFERENCE ONLY AND IS OCCUPANCY. NO RETAINAGE SHALL BE RELEASED UNTIL OWNER HAS RECEIVED THESE DESIGN MUST BE APPROVED BY OWNER AND MECHANICAL ENGINEER IF EMPLOYED BY INTENDED TO ONLY SHOW SWITCH LOCATIONS. REQUIREMENTS FOR DUAL SWITCHING, 87. PROVIDE CODE-COMPLIANT BLOCKING WITHIN WALLS AS REQUIRED FOR PROPOSED AND ITEMS. ARCHITECT PRIOR TO CONSTRUCTION. AUTOMATIC AREA SHUT OFF CONTROLS AND ALL OTHER CODE REQUIREMENTS SHALL BE THE FUTURE ACCESSORIES AND GRAB BAR MOUNTING FIXTURES. BLOCKING IS REQUIRED FROM 21. ALL DEMOLITION WORK TO CONFORM TO CURRENT OSHA STANDARDS. PROVIDE ADEQUATE 42. PAY ALL FEES AND OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES RESPONSIBILITY OF THE DESIGN-BUILD CONTRACTOR. PROVIDE A MINIMUM OF ONE SWITCH STUD SPACE TO BACK OF SURFACE OF ALL FIXTURES INCLUDING BUT NOT LIMITED TO BRACING ON EXISTING CEILING FRAMING SYSTEM PRIOR TO DEMOLITION. NECESSARY TO COMPLETE WORK. PER ROOM, UNLESS OTHERWISE INDICATED. TUB/SHOWER ENCLOSURES. 43. COORDINATE ITEMS REQUIRED FOR DEMOLITION NOT INDICATED ON DRAWINGS. 67. PROVIDE ILLUMINATED EXIT SIGNS AT REQUIRED EXIT DOORWAYS AND WHERE NECESSARY DOOR AND HARDWARE 44. COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL SYSTEM. TO INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF 88. FLOOR DRAINS: ACCESSIBLE FIXTURES REQUIRE A CLEAR FLOOR SPACE CONTIGUOUS OR 45. DESIGN-BUILD CONTRACTOR SHALL PREPARE A WRITTEN SCOPE OF HVAC WORK WITH BID. FIFTY OR MORE. OVERLAPPING THE ACCESSIBLE ROUTE. FLOOR DRAINS SHOULD NOT BE PLACED IN THIS 22. DOORS SHALL OPEN FROM THE INSIDE WITHOUT THE USE OFA KEY OR ANY SPECIAL THIS IS TO INCLUDE NEW EQUIPMENT, NUMBER OF ZONES, DESCRIPTION AND QUANTITY OF 68. PROVIDE ILLUMINATION AT EXITS WITH LIGHT HAVING THE INTENSITY OF NOT LESS THAN 1 CLEAR FLOOR SPACE. EXCEPTION: DRAINS MAY RESIDE IN CLEAR FLOOR SPACE PROVIDED KNOWLEDGE OR EFFORT. CONTROLS AND THERMOSTATS, ETC. OWNER WILL REVIEW SCOPE OF WORK PROPOSED FOOT-CANDLE AT THE FLOOR LEVEL. PROVIDE EMERGENCY SYSTEM LIGHTING WHERE THE DRAIN HOLES DO NOT EXCEED 1/2"DIA. MAX.;FLOOR SLOPE DOES NOT EXCEED 2%IN ANY DIRECTION;AND THE ELEVATION CHANGE AT THE DRAIN LIP DOES NOT EXCEED 1/8". END OF GENERAL NOTES PROJECT NUMBER: 216248 Healthy Living Tenant Improvement Fanno Creek Place Building B . 16083 SW Upper Boones TYPICAL AT DOOR Ferry Road EXIT SIGN Suite 100 4'-0" = Tigard, Oregon 97224 • ELECTRICAL OUTLET ♦ �, . TYPICAL DOOR "� I II ♦ w , - OPENING /9 TO RAISED ELECTRICAL OUTLET `A.741 , ,11, LCHARACTERS :TCA:E1i7 WORK 111111 'z 011 !9 Li NI b ♦ V ��I���yi J �' C.4-E ♦ �X X10 MAX `�' c � O v ~ LU = ¢ r= 2'-6" Fig. 308.2.1 Fig.308.3.1 CARD v n 10 Mo ¢ z CLEAR FLOOR SPACE CLEAR FLOOR SPACE UNOBSTRUCTED UNOBSTRUCTED READER o o z PARALLEL APPROACH FORWARD APPROACH FORWARD REACH SIDE REACH i- I- o N. i. ♦ - r �`#,_ ��_ ` �� � 4"MAX rf TYPICAL AT DOOR MISCELLANEOUS WALL MOUNTINGS O 2 IFV�+P\ 2 9 �t. �i ItirittiN1 '���i�t� OPERABLE THERMOSTAT FIRE ALARM SIGNALISTROBE ANNUNCIATOR PANEL C���►�� �1.C7-� i FIRE EXTINGUISHER SIGN WALL MOUNTED FIRE SHEET TITLE: �, >20"-25" Z MOUNTED PHONE EXTINGUISHER EMERGENCY POWER 3 20"MAX g 111 RECESSED FIRE OFF PUSH BUTTON Fig.308.2.2 b �'ir 0 ♦ STATION MANUAL PULL EXTINGUISHER CABINET :Tc ♦ TACTILE General Notes OBSTRUCTED HIGH FORWARD REACH INTERCOM SIGNAGE Standard Mounting N TELEPHONE STATION �' _ \ BASE OF �a 10"MAX >10"-24" A OUTLET AND � � � , a tir . , ♦ ' ♦ SWITCHES CHARACTER Heights �. LIMITS OF PROTRUDING OBJECTS c}+♦ D � of 111 z a -''� of 2 N k 2 >� EXCEPTIONS: O w w w O z `� z - "♦ z � . 2 1. HANDRAILS MAY PROTRUDE 41/2 MAX, o re o Q o 0 0 o Ix o Ex us brill w - LL co co Ut w o Co o r) 2. DOOR CLOSERS AND DOOR STOPS cA z LL O 0LL. 0LI- v m v ♦ SHALL BE PERMITTED TO BE T8"MIN a a O ABOVE FLOOR o ~ DRAWN BY: PMK Fig.308.3.2 ♦ ♦ ♦ ♦ ♦ ♦ ♦ NI, 1k N4 N4 ♦ ♦ OBSTRUCTED HIGH SIDE REACH ICC/ANSI A117.1-2009 SECTION 308 REACH DATE ISSUED: 11.29.2016 al RANGES(ALL DIMENSIONS ARE NOT TO SCALE) MISCELLANEOUS WALL MOUNTINGS 0 C LL m a N . O 591. A CCESSIBLE FIXTURE MOUNTING REQUIREMENTS (PER ICC/ANSI A117.1-2009) a SCALE: NOT TO SCALE Ai 00 SHEET: 0 Z N LRS Architects,Inc.®2016 1= co PERMIT SET 11.29. 16 •Y 0. F 1 ® N L FS — c 111 OFFICES z ARCHITECTS 4 (,k(1b 0 - --_—� � — _ 4r 4.44_ OPEN 720 NW Davis 503.221.1121 `� 0os o o Ds --- OFFIC1E Suite 300 503 221.2077 Z—f 1.� 'Ll] � ■ 0 (---_-------\_0„. L■I ■ S X w_ w O n ji [' +ss•i Oas" 04 d 1.__:.?-c Portland OR 97209 www.Irsarchitects.com - _EEC ,j 31,4"41► BREAK :::(1:V1-02>( s (N) _, ROOM , 10" 102 N� ( F GAT-1 �/ COPY CT-�,�car-1 AREA O N102 - 105 ALIGN - L1. --I— --I- I�==i= NS I N �� I�� Imo` Il Imo` KV O �N106 SN i �� ilito II II No OS N tt, N hgmiuMIVHEI1EC1 O - _u_. �� 3 1--4,- -,,i; ` U II ir8'x6',TYPICAL a C7 M O ) ) OPEN u (c )) U SUITE I II I 'OFFICE II I�' Z O OPEN (ittASIARTT • �. r— E100 ENTRY I II I 10111 I `' 4 OFFICE ri 1 0. ��O u car-1 100 1L==1= i==1= IL 107 44 " OF 4'4*3'-4"'� '�3'-4"'r •0 'r 3'-4" N (N) (N) ALIGN N107 2 O = a Ar - , ii Jo: OJJçO SDSO O w Lu 0 NS ci O 1 U u ■ O W W W DS co C7 4eN 1 u ■ ,. CONF. ROOM 0 OFFICE 0 OFFICE 0 OFFICE ¢ CONSULTANT: 111 110 O 109 108 — 0 •�`O� �' N O N W is: 1 v 90 , 1 �Q 3 1_1-11 1 4-1 1 11 .11 11� II --- .4 I If ii it 1 lint11 - . 4 I 11/44® +s) 1. DEMOLITION PLAN 2. PROPOSED FLOOR PLAN SCALE: 1/8"= 1'-0" SCALE: 1/8"= i'-0" DEMO PLAN GENERAL NOTES DEMO PLAN KEYNOTES FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. A.REMOVE PORTION OF EXISTING WALL TO INSTALL NEW BUILDING STANDARD INTERIOR A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. O PROVIDE NEW BUILDING STANDARD 8'HIGH DOOR,FRAME,HARDWARE AND 3'WIDE RELITE. B. PROTECT ALL ADJACENT AREAS DURING DEMOLITION&FROM DUST AND TRASH INTRUSION. RELITE.REFER TO 2/A201 FOR ADDITIONAL INFORMATION.COORDINATE R.O.PER NEW B. DIMENSIONS ARE TO FACE OF WALL UNLESS OTHERWISE NOTED. ADVISE ARCHITECT OF RELITE SIZES. ANY DISCREPANCIES PRIOR TO CONSTRUCTION. O PROVIDE NEW BUILDING STANDARD 8'HIGH DOOR WITH FULL LITE,FRAME AND HARDWARE. C. REMOVE BLINDS&WINDOW COVERINGS FOR REUSE.CLEAN AND REINSTALL PRIOR TO JOB O REMOVE PORTION OF EXISTING WALL.PATCH AND PAINT AS NECESSARY.RELOCATE 3® PROVIDE NEW BUILDING STANDARD 3'WIDE x 8'HIGH RELITE. COMPLETION.REPAIR AND/OR REPLACE ANY MISSING AND/OR DAMAGED WINDOW C. PROVIDE NEW BUILDING STANDARD FLOORING AS INDICATED&RUBBER BASE(RB-1). EXISTING SEMI-RECESSED FEC PER PROPOSED PLAN 2/A201. COVERINGS TO MATCH EXISTING AS NEEDED THROUGHOUT ENTIRE AREA OF WORK. REPAINT ENTIRE SUITE WITH(1)BUILDING STANDARD PAINT COLOR(P-1)UNLESS O PROVIDE NEW BUILDING STANDARD 7'WIDE x 3'HIGH CLERESTORY RELITE. TOP TO ALIGN WI 0 REMOVE EXISTING POWER-POLE AS NECESSARY. OTHERWISE NOTED. TOP OF DOOR FRAME-VERIFY W/TENANT PRIOR TO CONSTRUCTION. D. REMOVE AND SALVAGE FIRE EXTINGUISHERS&CABINETS FOR REUSE. PROVIDE AS REQUIRED BY CODE. 4O REMOVE EXISTING THERMOSTAT.RELOCATE PER PROPOSED FLOOR PLAN 2/A201. G. ALL ELECTRICAL WORK IS DESIGN BUILD-ALL ELECTRICAL OUTLETS,DATA&SWITCHES O PROVIDE POWER AT WALL FOR(6)TENANT-PROVIDED CUBICLES. SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS. SUBMIT ELECTRICAL PLANS E. REMOVE&SALVAGE DOORS,FRAMES,&RECITES FOR REUSE. 0 UTILIZE EXISTING BLANK OUTLETS TO PROVIDE NEW POWER AND DATANOICE OUTLETS. TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. O RELOCATED EXISTING SEMI-RECESSED FEC. F. CEILING CONFIGURATION TO REMAIN UNLESS OTHERWISE NOTED. H. PATCH AREAS ADJOINING AND/OR ADJACENT TO DEMOLITION WORK TO MATCH EXISTING AND/OR NEW CONSTRUCTION. I. WHERE NEW DOORS,FRAMES&HARDWARE ARE PROVIDED,MATCH EXISTING BUILDING LEGEND FINISH LEGEND STANDARD TYPE,SIZE,FINISH&COLOR. TOUCH UP EXISTING FRAMES&DOORS WHERE NEEDED TO APPEAR AS NEW. PARTITION CARPET LEGEND J. PROVIDE J-BOX AND PULL STRING FOR TENANT-SUPPLIED VOICE&DATA. CPT-1 BUILDING STANDARD,TO BE SELECTED NEW BUILDING STANDARD PARTITION- EXISTING PARTITION K. FURNITURE SHOWN FOR REFERENCE ONLY. SEE 4/A201 FOR DETAIL VINYL COMPOSITION TILE VCT-1 BUILDING STANDARD,TO BE SELECTED (N) NEW 3'WIDE RELITE,U.O.N. PROJECT NUMBER: 216248 C 3 DEMO EXISTING ELEMENT SWITCH RUBBER BASE SWITCH-OCCUPANCY SENSOR RB-1 BUILDING STANDARD,TO BE SELECTED °S PAINT Healthy Living P TELE/DATA OUTLET P-1 BUILDING STANDARD,TO BE SELECTED Tenant Q- DUPLEX OUTLET GF DEDICATED DUPLEX OUTLET Im pro vem en t DEDICATED 120V 60HZ 20AMP NEMA TYPE 5-20R N NEW Fanno Creek Place RL RELOCATED Building B THERMOSTAT 16083 SW Upper Boones JO J-BOX FOR TENANT PROVIDED FURNITURE WHIP Ferry Road Suite 100 Tigard, Oregon 97224 l L _1 0f0 RCPGENERAL NOTES LEGENDEND /Z • V • • — A. REFER TO SHEET A100 FOR A COMPLETE LIST OF GENERAL NOTES. EXISTING 2X4 ACOUSTICAL SUSPENDED CEILING • — 7 / B. ALL ELECTRICAL WORK IS DESIGN BUILD-EXISTING&NEW LIGHT FIXTURES SHOWN FOR PROVIDE(2)#8 SHEET METAL f REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO \ EXISTING BUILDING STANDARD LIGHT FIXTURE SCREWS AT EX BRACE • / ARCHITECT. SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO ATTACHMENT TO STRUCTURAL 20 GA.3 5!8"STUD BRACING TO ■ \ n I x CONSTRUCTION. CLEAN&RESTORE ALL LIGHTS TO WORKING ORDER PRIOR TO JOB MEMBER TYP. STRUCTURE(�8'-0"O.C. IIEXISTING BUILDING STANDARD EGRESS LIGHT IcCOMPLETION. PROVIDE 2"X 1/8"LIGHT&SOUND e 7 FIXTURE SEALING GASKET CONTINUOUS • F 'D C. ALL MECHANICAL WORK IS DESIGN BUILD-EXISTING DIFFUSERS SHOWN FOR REFERENCE D DEMO BETWEEN WALL&CEILING , ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT. $, • • / • r ® • - SUBMIT MECHANICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. N NEW till— ,� • __ a'-e"AFF ' �/�I� CLEAN ALL DIFFUSERS PRIOR TO JOB COMPLETION. VERIFY HEIGHT IV RL RELOCATED Cl 0'4D , i �� SHEET TITLE: 1' o D. SUBMIT PROPOSED LOCATIONS FOR EMERGENCY LIGHTING,STROBES,SMOKE DETECTION ® EXISTING EXIT SIGNS PROVIDE(2)FASTENERS @ EA. i . RL &SPRINKLERS TO ARCHITECT FOR REVIEW AND COORDINATION PRIOR TO CONSTRUCTION. Construction Plans 7g - N ! BRACE STUD CONNECTION TO TOP ►j 10,_0117 +8'-10 CEILING HEIGHT AFF OF WALL STUD � cc, ~- X X E. REPLACE ALL DAMAGED CEILING TILES&GRID TO MATCH EXISTING BUILDING STANDARD., 0 A1 > F. WHERE NEW LIGHTS ARE ADDED-MATCH EXISTING BUILDING STANDARD TYPE AND FINISH.53 X� EXISTING HVAC SUPPLY/RETURN i� • EXISTING SPRINKLER HEAD 3-5/8"25 GA.(362S125-18)MTL G. EGRESS LIGHT CONFIGURATION SHOWN FOR SCHEMATIC PURPOSE. EXIT ILLUMINATION • STUDS @ 24"O.C.WITH 5/8"GYP. • • • • • >9 • THROUGH DEFERRED SUBMITTAL. EXISTING FIRE STROBE LIGHT BD.EACH SIDE. PROVIDE 3"SOUND �•; E 73© ATTENUATION BATT INSULATION Fw � 2 0 ® EXISTING SMOKE DETECTOR FRICTION FIT IN STUD SPACE AND ►t o I 1 , 11 ACOUSTIC SEALANT(a CEILING �i ■ GRID. POWDER DRIVEN ANCHOR DRAWN BY: PMK § / xl ' • • • x A • �� ATE ISSUED: 11.29.2016 T AT 2'-0'O.C..THRUM . • — BASE ON BOT SPECIFIED STUD TRACK,UON 1 �1� ,i,1 ____ EXISTING SLAB 7: I I I I 1 I I I RCP KEYNOTES - Et I 1OREMOVE EXISTING CEILING J BOX FEED OUTLET. 3. REFLECTED CEILING PLAN 4. BUILDING STANDARD PARTITION ® REMOVE EXISTING CEILING-MOUNT EXIT SIGNAGE.RETURN TO LANDLORD'S STOCK PILE. SCALE: 1/8"= 1`-0" SCALE: //2"= V-0" a O SWITCH EXISTING EGRESS LIGHT-SCHEMATIC LAYOUT ONLY. A201 2 E SHEET: E z a, LRS Nchrtects,Inc.©2016 N N co Ed PERMIT SET 11.29. 16 E Q. �Z