Plans (3) BU P2016 - 00277
cop *4.
p a \,,,..7
p p_ \,....,:r=
ENTRy
E � :i�ill 1� YOUNG
M '
Ygi �D I r �� �� to•
GENERAL NOTES = ,IF)— ° F .
_ a CEI� -L' OF O`
L THESE PLANS FOR TENANT IMPROVEMENT ONLY_ 1 1 rt-)N
101 0 .., S 192016
2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, \ I I 'r ., •• I - �' ,1 8..//OccaiP_ I CITY°EDGARD
PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST
TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF L _ HMO%DIVISION
THE PROJECT IN COMPLIANCE WITH THE APPLICABLE
GOVERNING BUILDING CODES AND REGULATIONS_ WHERE RECPt. O r-+
11°21:5'V/70 m 00
MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND , N csi
SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT IS THE _ '_I occur to
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
DE=TERMINE SPEGIFlC LOCATIONS, PROVIDE SPECIFIC111
t OFFICE p�
gs 1031 m
MATERIALS AND DETERMINE CONSTRUCTION DETAILING, i X 13•0s.p A"
ALL IN COMPLIANCE WITH APPL1CABLE BUILDING CODES, Ei 0 O
REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS <r.
AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S ill 3a ' b0�
RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS IN ' -�,� "Is ' '," �'' 4.4
COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. ■} 0
3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL EEA ■
MEANS, METHODS, TECHNIQUES AND SEQUENCES OF OFFIG , �m CONSTRUCTION INCLUDING JOB SITE SAFETY. THE r , I104�Ips sF_i�m - tiARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, - OPEN OFFICE m •2OCA :‘,:\.:,!:..,t,'",'.,.,,,,.,..,,::,::,
a0METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION 113J • ;�
INCLUDING JOB SITE SAFETY. .4 eF �
.43 OC.dJP.
3I)CI
4_ THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE #I
ALL THE LABOR, MATERIALS, TRANSPORTATION EQUIPMENT, exp , a._s:':
AND SERVICES NECESSARY FOR AND REASONABLY
INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION u u I I - a .t_ OFFICE l
WORK IN CONNECTION WITH THE DOCUMENTS.
X 1105 I . ,� ,i,':: \,,3 00 o
^rn yam sF �mmM X N
.1 OCCUP.
5_ APPLICABLE CODES ON MATERIALS AND WORKMANSHIP r'.=g.t0 mm0"~E '
intltf=ten
. SHALL CONFORM TO THE 2014 OREGON STRUCTURAL 1 `4...01 XI cn
SPECIALTY CODE AND APPLICABLE STATE AND FEDERAL �! O
SAFETY ORDERS. ALL REFERENCES TO CODES �`
SPECIFICATIONS, AND STANDARDS SHALL MEAN AND ARE V'xi. v f1+ E-'
INTENDED TO BE THE LATEST EDITION, AMENDMENT PROVIDE POWER POLES (1 OF 3)
AND/OR REVISION OF SUCH REFERENCE STANDARD IN I VERIFY LOCATION W/TENANT _
EFFECT. =,== ,==mom==�==
'41
B o l�E
€ � X 106 °J-P-= imm
6. EACH SUB-CONTRACTOR (OR THE GENERAL CONTRACTOR €1 s In = e,9 ':4BFocc,We
WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE RSB fl Ii =
WORK) IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE
titsi
FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, i_i crl
.�{ -
NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF - ADA HEIGHT _
I TRANSACTION NI '®ANY WORK GALLED OUT ON THE DRAWINGS IN HIS TRADE � a X36 AFF_ VI
THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT Fommtq;mmP ;Pim F. rF '
MEET CURRENT LOCAL BUILDING CODES. 1i : - 1101 I iii 1OIL T I�"1 ����-� :L:
I. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL -•-' 'n61/
3°x10DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE / -.DRAWINGS AND SPECIFICATIONS AS WELL AS THEt E! I �F-011I 13
•t
PHYSICAL CONDITIONS OF THE SITE. NOTIFY THE € p vERIi=Y °x 6mx ®x �mxARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK m-,, m r z , .-Du � - �ipI� Rl t
., lUS. DIMENSIONS ARE FROM FACE OF FINISH MATERIAL. €1 ' /` ii p �i P OS I Icil TM ° @ OFFICE
tiF 3 S �r in 1.1 . I2m6 B ./100 mV
e. PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY i,
NEW WORK TO EXISTING CONDITION OR NEW CONDITION, 1f2oca�p
WHICHEVER IS APPROPRIATE_ _ NI
tIil
-RI
In /icy 132 (;60(0)0
,_ I!4i _ _ occur. .s arm. .z occur. .s ocr10. EACH SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC IPLANS AND SECTIONS AND MUST COORDINATE THEIR WORK M Ni,WITH ALL TRADES TO AVOID CONFLICTS_ • • 11 1 - - - 1 .. — — N
1L DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF J
SECTION 1004.3 - OREGON STRUCTURAL SPECIALTY CODE 1144
QAND SHALL BE EITHER A LEVER OR PANIC TYPE r
REQUIRING ONLY A SINGLE MOTION TO OPEN_KEY-LOCKING NORTH MORN r
HARDWARE MAY BE USED ON THE MAIN DOOR OF 8, F, M • I--I
ORE OCCUPANCIESH ONLY, WITH THE UNLOCKED DOOR Ali DEMO FLOOR PLAN Alk FLOOR PLAN
FREE TO SWING WITHOUT OPERATION OF ANY LATCHING
DEVICE AND A READILY VISIBLE DURABLE SIGN POSTED i8" - 1'-0"
ON THE EGRESS SIDE IMMEDIATELY ABOVE THE DOOR '. '. ''8H� 1'-0" O
STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING
IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1" HIGH ON
CONTRASTING BACKGROUND_
12. PROVIDE TEMPERED GLAZING AT WINDOWS 4 RELIGHTS
PER SECTION 2406 - OREGON STRUCTURAL SPECIALTY r.
CODE_ TOP OF RELIGHT FRAMES TO MATCH TOP OF DOOR
FRAMES_ CODE SUMMARY
13. VERIFY KEYING REQUIREMENTS WITH TENANT AND !n ° ° ° GENERAL BUILDING DESCRIPTION: GENERAL OFFICE/WAREHOUSE
LANDLORD. t NUMBER OF STORIES: 1
OS-24-16
fl FIRE SPRINKLERS: 100% COVERAGE
14. PROVIDE 31/2" UNFACED BATT INSULATION AT ALL NEW BUILDING SIZE: 63,000 SF_±
WALLS. '!I I' sag-I�-1(0
OCCUPANCY: 5 S-!
CONSTRUCTION TYPB III-B
15_ PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE TENANT SPACE SIZE: 63,000 SF.±
MARSHALL AT WALK-THROUGH_ PPV1
H
16.PROVIDE HVAC W/20 CFM OUTSIDE AIR PER OCCUPANT AT s LEGEND
o
OFFICE AREAS. , ���
II MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE a
IT
PERMITS. \-i : 78 0 EXISTING WALL TO REMAIN
18_ MAINTAIN 100% FIRE SPRINKLERS PER F.M.O. 4 LATEST • ° ° ° ° ° t
EDITION OF NFPA PAMPHLET *13. I - r_� �" mm EXISTING WALL TO SE REMOVED
- LI. 11 NEW WALL - 3 " METAL STUDS e 24"
19_ FIRE SPRINKLERS TO BE LOCATED IN THE CENTER 2'-0" X Lll
OE_ 5JB" GYP_ BD_ EACH SIDE CM Y Or TIGARD
2'-0" CEILING TILES OR IN THE CENTER OF EITHER HALF OF ° ° ° ° '!4ii_i
FOR CO COMPLIANCE
A 2-'0" X 41-0" CEILING FILE_ r I---1 (1 EXISTING DOOR TO REMAIN
ilb& _
, , -J zippi+ OTC: I I �-1bSQ-C\ 12` 51 C-'
IN j NEW OR RELOCATED DOORPet Z� — Z
° ° i
3'-0"x-1'-0" U.O.N.
y Address: 7 J-
Suite#. qrri
1' DOOR TO BE REMOVED ORB b. r�TY: ``i1' Dates itsj47
1 e � RELOCATED �,
NEW DUPLEX ELECTRICAL OUTLET.
* BOTTOM OF COVER PLATE TO BE AT OFFICE COPY
115" A.F.F.- ,,,..
NEW MUDRING AND PULL WIRE FOR J
_InE — I/.. of � ♦ TENANT PROVIDED PHONE AND DATA
- 4, j% / WIRING. BOTTOM OF COVER PLATE TO
F171BE ATI " A,F.F.
L L
NOR1I-1 AREA OF
WORK
ilk BUILDING KEY PLAN
CITY OF TIGARD
lir NOT To SCALE Approved by Planning A._
1
Date: 1110 0 `I"
Initials:
Al/-
OF 2
\\, , 1 601 AkY.,
Ai,-..,R, *****A
wil .. : 1 , O G
e MI • i$ 1 ,,oR •
111 i),, ...
OF O
. Mini
_„„:„: 111‘
sE nN `,Ae v,. FR Bow00N
Nr
N
N
• illI h
fi,..nrob .c1
x,•..mIggi 04404 ,� ..
. 420000, o
.. . \ . \ \ 1 \
MN DI
” \ A
•
`.. _ TE. _ _ _ /V P \, , 0 0000
r f - 1'f , ii ,1 ��L _ kw
X N
Ijil . , •
O
Er 4—__ . N . \
tem\ •
_ i► ' N Nk . Fes : a EH
.•e
\ . ,
- - _1 t .
3'-2" \ `
I _
1'-4" y 1'-0"
PLAM O
i L I _., . v
L _ _J
f z 64
a
PLAM 0 '�
w Iii
PARTIAL REFLECTED CEILING PLAN z o
i- 1
I I y ID0
0
_ LEGEND
• EXISTING SPRINKLER HEAD LOCATION f-� in }
EXISTING= HVAC RETURN W fes-{ r
1.
u' p EXISTING HVAC DIFFUSER O
Nk .
/ EXISTING 2X4 FLUORESCENT FIXTURE Z
CASEWORK SECTION TO REMAIN O
I" r EXISTING 2X4 FLUORESCENT FIXTURE }
4(,.-2 =1'-0°
TO BE REMOVED
NEW OR RELOCATED 2X4
FLUORESCENT FIXTURE
24 HOUR NIGHT LIGHT CIRCUIT WITH
BATTERY SACK UP
ESO ILLUMINATED EXIT SIGN WITH BATTERY 08-24-16
\ BACK-UP
\\: \\ \� \� \ \� \ \ \ \� // I NOTE: HVAC DIFFUSERS 4 RETURNS ANO FIRE 09-15-16
\ \ \ \ SPRINKLERS SHOWN ONLY IN EXISTING
LOCATIONS FOR CONTRACTORS CONVENIENCE.
\\ \ \ \\ \\ // \ CONTRACTOR TO RELOCATE HVAC DIFFUSERS 4
\ \ \ / / RETURNS AND FIRE SPRINKLERS TO SATISFY
iBUILDING, MECHANICAL AND FIRE CODE./ ' / / /
I / y / y ,
alk INTERIOR OFFICE ELEVATION
A -2 +4°-1'-0"
\ / / /
/// [III
// //\ // // /i// /j / //// // // \ // O A *16,015
/ \ \ \
J 1 L _ .+ ,
1 INTERIOR OFFICE ELEVATION
A -2 16.4„_1'-0"
A. 2
OF 2