Loading...
Plans (3) BU P2016 - 00277 cop *4. p a \,,,..7 p p_ \,....,:r= ENTRy E � :i�ill 1� YOUNG M ' Ygi �D I r �� �� to• GENERAL NOTES = ,IF)— ° F . _ a CEI� -L' OF O` L THESE PLANS FOR TENANT IMPROVEMENT ONLY_ 1 1 rt-)N 101 0 .., S 192016 2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, \ I I 'r ., •• I - �' ,1 8..//OccaiP_ I CITY°EDGARD PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF L _ HMO%DIVISION THE PROJECT IN COMPLIANCE WITH THE APPLICABLE GOVERNING BUILDING CODES AND REGULATIONS_ WHERE RECPt. O r-+ 11°21:5'V/70 m 00 MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND , N csi SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT IS THE _ '_I occur to RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DE=TERMINE SPEGIFlC LOCATIONS, PROVIDE SPECIFIC111 t OFFICE p� gs 1031 m MATERIALS AND DETERMINE CONSTRUCTION DETAILING, i X 13•0s.p A" ALL IN COMPLIANCE WITH APPL1CABLE BUILDING CODES, Ei 0 O REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS <r. AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S ill 3a ' b0� RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS IN ' -�,� "Is ' '," �'' 4.4 COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. ■} 0 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL EEA ■ MEANS, METHODS, TECHNIQUES AND SEQUENCES OF OFFIG , �m CONSTRUCTION INCLUDING JOB SITE SAFETY. THE r , I104�Ips sF_i�m - tiARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, - OPEN OFFICE m •2OCA :‘,:\.:,!:..,t,'",'.,.,,,,.,..,,::,::, a0METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION 113J • ;� INCLUDING JOB SITE SAFETY. .4 eF � .43 OC.dJP. 3I)CI 4_ THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE #I ALL THE LABOR, MATERIALS, TRANSPORTATION EQUIPMENT, exp , a._s:': AND SERVICES NECESSARY FOR AND REASONABLY INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION u u I I - a .t_ OFFICE l WORK IN CONNECTION WITH THE DOCUMENTS. X 1105 I . ,� ,i,':: \,,3 00 o ^rn yam sF �mmM X N .1 OCCUP. 5_ APPLICABLE CODES ON MATERIALS AND WORKMANSHIP r'.=g.t0 mm0"~E ' intltf=ten . SHALL CONFORM TO THE 2014 OREGON STRUCTURAL 1 `4...01 XI cn SPECIALTY CODE AND APPLICABLE STATE AND FEDERAL �! O SAFETY ORDERS. ALL REFERENCES TO CODES �` SPECIFICATIONS, AND STANDARDS SHALL MEAN AND ARE V'xi. v f1+ E-' INTENDED TO BE THE LATEST EDITION, AMENDMENT PROVIDE POWER POLES (1 OF 3) AND/OR REVISION OF SUCH REFERENCE STANDARD IN I VERIFY LOCATION W/TENANT _ EFFECT. =,== ,==mom==�== '41 B o l�E € � X 106 °J-P-= imm 6. EACH SUB-CONTRACTOR (OR THE GENERAL CONTRACTOR €1 s In = e,9 ':4BFocc,We WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE RSB fl Ii = WORK) IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE titsi FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, i_i crl .�{ - NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF - ADA HEIGHT _ I TRANSACTION NI '®ANY WORK GALLED OUT ON THE DRAWINGS IN HIS TRADE � a X36 AFF_ VI THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT Fommtq;mmP ;Pim F. rF ' MEET CURRENT LOCAL BUILDING CODES. 1i : - 1101 I iii 1OIL T I�"1 ����-� :L: I. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL -•-' 'n61/ 3°x10DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE / -.DRAWINGS AND SPECIFICATIONS AS WELL AS THEt E! I �F-011I 13 •t PHYSICAL CONDITIONS OF THE SITE. NOTIFY THE € p vERIi=Y °x 6mx ®x �mxARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK m-,, m r z , .-Du � - �ipI� Rl t ., lUS. DIMENSIONS ARE FROM FACE OF FINISH MATERIAL. €1 ' /` ii p �i P OS I Icil TM ° @ OFFICE tiF 3 S �r in 1.1 . I2m6 B ./100 mV e. PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY i, NEW WORK TO EXISTING CONDITION OR NEW CONDITION, 1f2oca�p WHICHEVER IS APPROPRIATE_ _ NI tIil -RI In /icy 132 (;60(0)0 ,_ I!4i _ _ occur. .s arm. .z occur. .s ocr10. EACH SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC IPLANS AND SECTIONS AND MUST COORDINATE THEIR WORK M Ni,WITH ALL TRADES TO AVOID CONFLICTS_ • • 11 1 - - - 1 .. — — N 1L DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF J SECTION 1004.3 - OREGON STRUCTURAL SPECIALTY CODE 1144 QAND SHALL BE EITHER A LEVER OR PANIC TYPE r REQUIRING ONLY A SINGLE MOTION TO OPEN_KEY-LOCKING NORTH MORN r HARDWARE MAY BE USED ON THE MAIN DOOR OF 8, F, M • I--I ORE OCCUPANCIESH ONLY, WITH THE UNLOCKED DOOR Ali DEMO FLOOR PLAN Alk FLOOR PLAN FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE AND A READILY VISIBLE DURABLE SIGN POSTED i8" - 1'-0" ON THE EGRESS SIDE IMMEDIATELY ABOVE THE DOOR '. '. ''8H� 1'-0" O STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1" HIGH ON CONTRASTING BACKGROUND_ 12. PROVIDE TEMPERED GLAZING AT WINDOWS 4 RELIGHTS PER SECTION 2406 - OREGON STRUCTURAL SPECIALTY r. CODE_ TOP OF RELIGHT FRAMES TO MATCH TOP OF DOOR FRAMES_ CODE SUMMARY 13. VERIFY KEYING REQUIREMENTS WITH TENANT AND !n ° ° ° GENERAL BUILDING DESCRIPTION: GENERAL OFFICE/WAREHOUSE LANDLORD. t NUMBER OF STORIES: 1 OS-24-16 fl FIRE SPRINKLERS: 100% COVERAGE 14. PROVIDE 31/2" UNFACED BATT INSULATION AT ALL NEW BUILDING SIZE: 63,000 SF_± WALLS. '!I I' sag-I�-1(0 OCCUPANCY: 5 S-! CONSTRUCTION TYPB III-B 15_ PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE TENANT SPACE SIZE: 63,000 SF.± MARSHALL AT WALK-THROUGH_ PPV1 H 16.PROVIDE HVAC W/20 CFM OUTSIDE AIR PER OCCUPANT AT s LEGEND o OFFICE AREAS. , ��� II MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE a IT PERMITS. \-i : 78 0 EXISTING WALL TO REMAIN 18_ MAINTAIN 100% FIRE SPRINKLERS PER F.M.O. 4 LATEST • ° ° ° ° ° t EDITION OF NFPA PAMPHLET *13. I - r_� �" mm EXISTING WALL TO SE REMOVED - LI. 11 NEW WALL - 3 " METAL STUDS e 24" 19_ FIRE SPRINKLERS TO BE LOCATED IN THE CENTER 2'-0" X Lll OE_ 5JB" GYP_ BD_ EACH SIDE CM Y Or TIGARD 2'-0" CEILING TILES OR IN THE CENTER OF EITHER HALF OF ° ° ° ° '!4ii_i FOR CO COMPLIANCE A 2-'0" X 41-0" CEILING FILE_ r I---1 (1 EXISTING DOOR TO REMAIN ilb& _ , , -J zippi+ OTC: I I �-1bSQ-C\ 12` 51 C-' IN j NEW OR RELOCATED DOORPet Z� — Z ° ° i 3'-0"x-1'-0" U.O.N. y Address: 7 J- Suite#. qrri 1' DOOR TO BE REMOVED ORB b. r�TY: ``i1' Dates itsj47 1 e � RELOCATED �, NEW DUPLEX ELECTRICAL OUTLET. * BOTTOM OF COVER PLATE TO BE AT OFFICE COPY 115" A.F.F.- ,,,.. NEW MUDRING AND PULL WIRE FOR J _InE — I/.. of � ♦ TENANT PROVIDED PHONE AND DATA - 4, j% / WIRING. BOTTOM OF COVER PLATE TO F171BE ATI " A,F.F. L L NOR1I-1 AREA OF WORK ilk BUILDING KEY PLAN CITY OF TIGARD lir NOT To SCALE Approved by Planning A._ 1 Date: 1110 0 `I" Initials: Al/- OF 2 \\, , 1 601 AkY., Ai,-..,R, *****A wil .. : 1 , O G e MI • i$ 1 ,,oR • 111 i),, ... OF O . Mini _„„:„: 111‘ sE nN `,Ae v,. FR Bow00N Nr N N • illI h fi,..nrob .c1 x,•..mIggi 04404 ,� .. . 420000, o .. . \ . \ \ 1 \ MN DI ” \ A • `.. _ TE. _ _ _ /V P \, , 0 0000 r f - 1'f , ii ,1 ��L _ kw X N Ijil . , • O Er 4—__ . N . \ tem\ • _ i► ' N Nk . Fes : a EH .•e \ . , - - _1 t . 3'-2" \ ` I _ 1'-4" y 1'-0" PLAM O i L I _., . v L _ _J f z 64 a PLAM 0 '� w Iii PARTIAL REFLECTED CEILING PLAN z o i- 1 I I y ID0 0 _ LEGEND • EXISTING SPRINKLER HEAD LOCATION f-� in } EXISTING= HVAC RETURN W fes-{ r 1. u' p EXISTING HVAC DIFFUSER O Nk . / EXISTING 2X4 FLUORESCENT FIXTURE Z CASEWORK SECTION TO REMAIN O I" r EXISTING 2X4 FLUORESCENT FIXTURE } 4(,.-2 =1'-0° TO BE REMOVED NEW OR RELOCATED 2X4 FLUORESCENT FIXTURE 24 HOUR NIGHT LIGHT CIRCUIT WITH BATTERY SACK UP ESO ILLUMINATED EXIT SIGN WITH BATTERY 08-24-16 \ BACK-UP \\: \\ \� \� \ \� \ \ \ \� // I NOTE: HVAC DIFFUSERS 4 RETURNS ANO FIRE 09-15-16 \ \ \ \ SPRINKLERS SHOWN ONLY IN EXISTING LOCATIONS FOR CONTRACTORS CONVENIENCE. \\ \ \ \\ \\ // \ CONTRACTOR TO RELOCATE HVAC DIFFUSERS 4 \ \ \ / / RETURNS AND FIRE SPRINKLERS TO SATISFY iBUILDING, MECHANICAL AND FIRE CODE./ ' / / / I / y / y , alk INTERIOR OFFICE ELEVATION A -2 +4°-1'-0" \ / / / /// [III // //\ // // /i// /j / //// // // \ // O A *16,015 / \ \ \ J 1 L _ .+ , 1 INTERIOR OFFICE ELEVATION A -2 16.4„_1'-0" A. 2 OF 2