Plans BU P2016 - 00086 01 00 00 GENERAL DATA 7. AT TOILET ROOMS USE 5/8'USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48'A.F.F. 26 00 00 ELECTRICAL : DESIGN I BUILD GENERAL REQUIREMENTS ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT LOCATIONS TO RECIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) GENERAL /( 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD W THICK WITH SQUARE,REINFORCED, 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. cO) STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. EXCEPT FOR HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD. #3082 2. VERIFY ALL DIMENSIONS AND CONDI TIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 9. AT FRP, PLASTIC LAMINATE,ETC.,WAINSCOT PANELING INSTALL WATER-RESISTANT GYPSUM BOARD. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOWSILLS TO BE ROUTED THROUGH BUILDING TENANT IMPROVEMENT for MARTIN W. HANSON ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. 4,:� 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. C 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING COR RESPONDING PANEL AND BREAKER. ID CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH RECEIVED CLA KAf�faS, OREGON CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE SYSTEM. 3. PROVIDE UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. • THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. WALL CONSTRUCTION EXECUTION 4. LIGHTING ENERGY MANAGEMENT IS REQUIRED 1N ALL BUILDINGS. t1J't]\!7Go 4. BY SUBMITTING A PROPOSAL CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING 5. OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. MAR 2 3 201 UA GE LINE EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW 6. TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT 4DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND CITY OF OF Q� ALLF INT HE AND INSTALLATION,DISPOSALDBYP C ST),EXCESSCLEANING NA (USEABLE FINISH MATERIALS SHALL BE MATERIALS LIGHTER THAN 18 GA. TIGA�a Ti?ANsLATioN soLuTioNs T TENANTSPACEMATERIALS EAS ION, SOFXMATERIALS AND ALL PREPARATION OF SUBSTRATE SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURETHAYOPERATE BUILDING DIVISION SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. INDICATED IN THE PROJECT NARRATIVE PROJECT #16010 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING DESIGNCALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. OFFICE LIGHTING STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OFA DISCREPANCY TO THIS FASTENERS SHALL BE AT LEAST 31NCHES FROM THE EDGE OF CONCRETE SLABS. 1. OFFICE LIGHT FIXTURES- LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL(NO SYLVANIA PROJECT CONSISTS OF REMODEL WORK TO 8,940 SF OF EXISTING OFFICE SPACE. WORK SHALL INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION BALLASTS) 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT 2. REST ROOM-WALL MOUNTED LIGHT FIXTURE(CLASS A SPACES)- PEERLESS CRW1-2 54T5HD SPR 277GEB10 INCLUDE BUT NOT BE LIMITED TO DRYWALUMETAL STUDS, SUSPENDED CEILINGS, LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDECr) 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS-TO PROTECT EXISTING JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE (1SE EMERGENCY MODULE PER PLAN) DOORS/FRAMES AND PAINTING. ALL WORK TO MEET ADA REQUIREMENTS. v CARPETS. STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 3. RECESSED LED DOWN LIGHT: LITHONIA LDN6 35/10 LO6 AR LD 277 TRW W AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. 8. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT 28 30 00 ELECTRONIC DETECTION AND ALARM AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR ilei 9. PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO THE PROJECT. GENERAL FIRE PROTECTION SPRINKLERING W COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH FOR HORN/STROBE DEVISES USE"SYSTEM SENSOR'SPECTRALERT ADVANCE DEVISES,OR APPROVED EQUAL. h+�j ) FIRE ALARM SYSTEMS r BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR. HEATING, VENTILATION &AIR CONDITIONING WORK ACTIVITIES. 6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE • 10.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING 7. FINISH QUALITY: RESTROOM FACILITIES. AREA PROCESS TRADE NOMENCLATURE 11.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER WAREHOUSE TAPE/FINISH COAT' TIGHT DOUBLE BUILDING INFORMATION TENANT INFORMATION Z COMMON BUILDING AREA BE USED FOR STORAGE. OWNER: PACIFIC REALTY ASSOCIATES, LP. TENANT: G o OFFICE/OTHER AREAS TAPE/2F[NlSH COATS•1 SMOOTH FINISH TAPED 12.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. USG"FIRST COAT" •SAND AFTER TAPE I FINISH COAT(S) 15350 SW SEQUOIA PKWY#300 LANGUAGE LINE TRANSLATION V) 13.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS PORTLAND, ORE 97224 SOLUTIONS 14.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, SHOWN ON PLANS. ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 09 91 23 PAINTING (503)624-6300 (PHONE) OCCUPANCY AREAS& LOADS: 4 15.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. INTERIOR: (503)624-7755(FAX) B 8,940a SF 90 OCC ,N 16.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. 1. WALLS: �y 17.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS, BLDG. #. PCC BLDG. #7 (�cC231) NUMBER OF EXITS REQUIRED ...0 O' a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL'PRIMER. B 2 EXITS ']Ri 0:CIn 18.PROVIDE'AS BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION.'AS BUILT" b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 62000R CONST. TYPE.: I II-B O+O n DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S SIG LATEX ENAMEL. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS FJ SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD 2. DOORS AND FRAMES: 1F�-11 N N CONTRACTOR'S FINAL PAYMENT UNTIL A5 BUILT'DRAWINGS AND 08 M MANUALS HAVE BEEN RECEIVED THIS BUILDING WILL HOUSES SEVERAL TENANTS INCLUDING THIS TENANT. THE \O� AND APPROVED. a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OFSEMI�L05S OIL EXISTING BUILDING IS A PARTIAL TWO STORY BUILDING OF 57,160 SF AND IS FULLY m.- 19.171S THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH BON DO,SAND AND PRIME PATCHES WITH SPRINKLERED. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 152 FEET. ��, O O FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF c. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITHin WHETHER OR NOT SHOWN ON THE DRAWINGS. PAINTER'S PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX ALLOWABLE AREA-UNLIMITED (IBC 507.2) a a W W CAULK,AND FINISH WITH SATIN OIL ENAMEL NONSEPERATED USES (IBC 302.3.1) 20.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". 21."ALIGN"AS USED IN THESE DOCUMENTS, MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WITH SATIN OIL PLANE,EITHER IMMEDIATELY ADJACENTTOONE ANOTHER OR ACROSS AN OPENING. RNEL. !F FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS REQUIRED,ANDRE VARNISH WITH SATIN VARNISH. 22.D0 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. 3. CEILINGS: 23.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN a. EXISTING GYP BOARD I PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. REPLACEMENT AT CONTRACTOR COST. AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL a REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE b. NEW GYP BOARD /PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS WITH MILLER'S 62000R 4480. DIRECTED AT CONTRACTOR'S COST. 4. GENERAL NOTES: V 1 W 24.SUBMTT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMITA MINIMUM OFTWMOCOPIES OF ALL SPRAY. [*> EL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE U O COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. TO POR w rnnxan.NrrG S 25.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND EXIT INN CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER RAGS AT THE END OF EACH DAY. LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE I ; 4 - s3 �� �� INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING ,.. . AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. L I 1 ' + + -OM .. 't.. CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE I i i ; f, APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE APPROVED IN WRITING BY e. PROTECT WORK OF OTHER TRADES. ; ; I ' + ��� IT' fin IiTr.r THE ARCHITECT PRIOR TO INSTALLATION. f. PROVIDE`WET PAINT'SIGNS A5 REQUIRED TO PROTECT NEWLY PAINTED FINISHES. ; ii ; I 26.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTR UST AND SCHEDULE ALL SERVICE N " ► / 10 00 00 SPECIALTIES INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. -- n�w7 r �� Y � \ o p � � GENERAL 10 28 13 REST ROOM ACCESSORIES 8 o Q _� � ' � . 1. REUSE EXISTING ACCESSORIES WHERE POSSIBLE. �_t171'3 t t 1�1_ ! A I ! d to Ai. REMOVE ALL EXESTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIORr„��<r- ,TO INSTALLATION OF NEW FLOORING. 2. PAPER TOWEL DISPENSER AND WASTE SEMI RECESSED(ONE PER REST ROOM)BOBRICK B-3944 JTL _- T/101 73 29 CUTTING AND PATCHING 3. LAVATORY MOUNTED SOAP DISPENSER 34 FL OZ.,6"SPOUT LENGTH BOBRICK B-8225 �', �� T t Ili 1 VV�� 11. ! i T ll ti.. . �� � go 1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK 4. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER BOBRICK 82888 =a) , �1 ,% x I I I Q ___l k., _ �� �4'''.-. " BEING UNDERTAKEN. 5. SURFACE MOUNTED TOILET SEAT COVER DISPENSER BOBRICK B-4221 1 r sw 7 wnvQ.UE �� 2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. 6. MIRROR STANDARD SIZES 1/4"PLATE MIRROR WITH EDGES"FLAT GROUND'BOTTOM EDGE SUPPORTED BYA r OUM 3. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. CONTINUOUS BS.GHT CHROME"J"METAL,5/16"X 3/8" (HEIGHT OF EXPOSED FACE)WITH CONCEALED LEG BUILDING LOCATION I I 4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT SCREWED TO THE WALL TO CARRY THE WEIGHT OF MIRROR. 4 SURFACES TO THE FULLEST EXTENT POSSIBLE 7. GRAB BAR SATIN FINISH BOBRICK B-6806 SERIES 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. 12 23 16 CABINET SPECIFICATIONS 1 LOCATION MAP 6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE#3 x 12"LONG REBAR DOWELS AT 24-0.C. MIN.WITH 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. I A-1 NOT TO SCALE 2ED 11 ) MIN.6"PENETRATION INTO EXISTING CONCRETE AND MIN.OF6"EXPOSURE INTO POUR BACK CENTER 2. AWI CUSTOM GRADE STAN DARDS FOR CASEWORK AND COUNTER TOPS U.N.O DOWEL IN SLAB. 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES,INCLUDING 4"TOE KICK EDGE BANDING V 1 ADDITIONAL COST. (MATCHING PVC ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS V 1 OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD } 08 10 00 DOORS AND WINDOWS MELAMINE FINISH. i 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER {{ 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR i a. BAXTER AND FLAMING. (503)225-0486 PVC EDGES. b. D&0 DOOR (503)205-5533 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. c. BENSON INDUSTRIES {503}907-2240 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. d. GRANT SUPPLY (360)887-0647 8. HINGES-BLUM#75M3580, 110 DEG.SELF CLOSING CUP ON(OR EQUAL). _ Q' * Q* Q Q ».OO 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION (OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. �---- ----- _ __ J__ 3. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, _ I _ I_ I I ___ _ _ _ I »•�---_ _ I_ _ I I I FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. '� 1 !--' I 1 - 4. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 10.PULLS 96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. O _ i - -r ��� rr7r� 4 - 11.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. = ,, T �' - 5. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR 0 RHODES SERIES U.N.Q. SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL Ilii I I I IF I I I I aJ O 6. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5'BACKSET. CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH 1-1--1---1-----f- ---1--_-1-_- - A�-_t_-_-_-_ It TO BE SEALED. MINIMIZE COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO • 7. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN WI STAIN AND FINISH ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE. I I I I I I { I APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 12.RESTROOMS LAVATORIES(WHERE APPLICABLE)-24"D P-LAM TOP ON PLYWOOD DECKING WITH 4"H P-LAM F -4--I--1----- ----1---i------} - ----� - +_ U SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS BACK SPLASH. 5"H FACE MOUNT AT 34"A.F.F. P-LAM WAINSCOT 48"H. SEE PLANS IF REQUIRED. i 1 I I I I I I , :*ri�� ,'`�i PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 21 00 00 FIRE SUPPRESSION : DESIGN I BUILD E, _,_. I-4-1----i•--- i i�, i ����'� - x N SAMPLE. I I I I i I I I I I I r�' p el 09 00 00 FINISHES 1. ADJUST EXISTING SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE CENTERED IN 2 X 2 CEILING TILE. LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD C� ___L. J_-_-1-. i__-_L--__L_-_ __-__I- - _- L - L - GENERAL CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. C .`�_1.�_ _I�-- ----L---1 - -1- --_1, �_J_ Q�Cl 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. C., _x_1.1.1. I _-4- �_ `i_iI c Q CA 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 22 00 DO PLUMBING 0 U QQQ a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS GENERAL REQUIREMENTS w v b. PLASTIC LAMINATES 1. CONTRACTOR TO SUBMTT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN AREA OF WORK U CALel P OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. U ,--I c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUTOFF VALVE FOR EACH SET OF d. PAINT RESTROOMS. LOCATE VALVE BEHIND HANDICAP TOILET IN MEN'S RESTROOM. - 0 e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BECA 0.1 f. TOILET PARTITIONS INSULATED, 2 BUILDING PLAN " g. HARDWARE 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277E LESS THAN 30 GAL 120v. PROVIDE HUB DRAIN AT A-1, SCALE 1"=30' (iDREVISION LOCATION. 3. EXTEND FINISH FLOORING UNDER ALL NEW CASEWORK 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P277V/30A. ADJUST WATER 09 21 00 GYPSUM BOARD FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. CONTACT MESHER SUPPLY FOR 1. GENERAL AVAILABILITY,(503)236-4148. 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH 6. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 2. 1"TYPE 5-12 SCREWS 12"O.C.UNLESS OTHERWISE NOTED. OR MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR DRAIN. 3. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN 7. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC PRIMERS. FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS APPROVED BY OWNER. PROVIDE A MIN.OF 12" 4. 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH ACCESS DOOR. COAT. PAINT AS INDICATED. PLUMBING-REST ROOM FIXTURES CITY OF TIG D 5. 4. ALL ONE HOUR RATED WALLS(WHERE APPLICABLE): ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER 1. REUSE EXISTING FIXTURES WHERE POSSIBLE REVILWI I) FOR CODE COMPLIANCE AT RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN 6• WITH 1"TYPE S DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS 4. TOILET WI FLUSHOMETER-AMERICAN STANDARD AS 2234.015 AT NON ACCESSIBLE STALLS AND 2305.100AT Approved: / AND INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD ACCESSIBLE LOCATIONS. FLUSHOMETER SLOAN FLUSH VALVE 111 OR TANK TYPE TOTOCST744SLAS Y1}? i + SPACING),EACH SIDE AND OPPOSITE SIDES. INDICATED ON PLAN. OTC: 4U 1OIr '"-t I 7' � � G� 5. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER 5. TOILET SEAT: BEMIS 1955SSC OR OLSONITE 10SSCT 8. METAL STUDS. 6. COUNTERTOP LAVATORY KOHLER K-2196-4,OR AMERICAN STANDARD RONDALYN r 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. 7. LAVATORY FAUCET-DELTA 501 DST Address" w l 7. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND 8. SEALANT OF PLUMBING FIXTURES: Suite #: On PATCH HOLES READY FOR PAINT. $L6 R.M.T.a. ALL SEALANT SHALL MATCH GROUT COLOR AT TILE SURFACES. B}; Date: A2-c-3 8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. WALL CONSTRUCTION MATERIALS b. SUBMIT SEALANT COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER APPLICATIONS. DATE: 1/15/16 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE JANITOR CLOSETS /� INSTALLATION. PERMIT/DID 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. OFFICE COPY PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. 2. JANITOR FLOOR SINK-MUSTEE 63M MOP SERVICE BASIN 24'X 24'X 10"OR SWAN MS2424 24'X 24". DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. 3. JANITOR FLOOR SINK FAUCET-CHICAGO FAUCETS 897 OR AMERICAN STANDARD 8344.112. 3. COW-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A44&'A446MGRADE A(33000 CITY OF TIGARD PSI)G60. PLUMBING-MISCELLAhE0U5 1. DRINKING FOUNTAIN-USE ELKAY NO-LEAD TWO-LEVEL SWIRLFLO NON CHILLED DRINKING FOUNTAIN,WALL Approved i I Planning 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR MOUNTED,BARRIER-FREE ACCESS WITH SURFACE MOUNTING PLATE,MODEL#EDFPBM117C,OR APPROVED AN APPROVED EQUAL EQUAL Date: /2 ? I I yA - 1 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM C-36. Initials:6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM C-630. BUILDING DEPARTMENT USE r � �' ; � i----....), �� � 's '��� 3082013 4/1,,,t,,, 8 9 10 11121314 5 1 �) MARTIN#3 A375 OH NSON �- - rp CLAKAMAS, OREGON, 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0'I 25'-0" 12'-6" 121-6" 12'-6" 1 . &O 010 F PROJECT #16010 i I I I I I i E� _) _ \11 U W CD) -E)1) — — — — — — — — — — — — — — — — — — ,.., I I I I 1 ------) L, 1 r------ 'Ow 8 CONFERENCE I V1 -x — te i of ill- RECEPTION I 8 8 n) d. 1 i i-p 7 STORAGE OFFICE OFFICE B- • 5T0- •GE MEN fII/ c�t� 118 117 115 d� cl �© TESTING ioa 1r 4 O'er `o t; y� , 112 �� ) , fW NN GI _____T__.}, i _I t.. 1___ r-- ' I r JAN. f I I n I111l , U ` `' `p vv 1 1 rr. : (" IT"'L ; :U ' 11 1 — _� CIRC. I 1 ADD 51DELJTE ADD 6 X 36 LITE KIT TO DOOR ' • k � 102 rl I� J To DOOR REMO E LEVER LATCH MD 8 4 % ',5 ®' L - ` INSTALL P115I I/WLL HARDWARE ' '9; k AREA OF WORK 1 . - L OI OMEN CONFERENCE y lim Nt 105 103 i I I I I I . 'f' - - - �/ I J I I � W �- AREA OF WORD a AIL OPEN OFFICE Z UQ OPEN OFFICE A-3 11051CDLI 0 - - _ ON GRADE DOCK HIGH - _ 119 a [---Ie., H I I ` I I I N C) Ag EN I , ,,_ ----- ....,__ ,3--, ..,,..____ ii-\:_ti o 1 -_i -.-4 L - ; C/) d a -r Z al 4 1 I I 1 I OFFICE OFFICE I OFFICE OFFICE0. _1--- \\,—._ IL 110 109 108 107] ).4 CO El NI T' T — — — - __II, — - I — I = • II — T� R — 1, 'I _ L� ° _ — _ V ( ,) — Z i PARTITION AND POWER PLAN " 0 11.1 A-2 SCALE 1/8"= 1'-0" FT--1,... . +-_ wci., c) , � oo� o, ow 0 r U U 11 61 &lin 0 51 / 4 a a REVISION 1. 2. 3. 4. 5. • 6. 7. 8. R.M.T. DATE: 1/15/16 PERMIT/BID . . ..3c011) 4/PCS:„.., ISI IMIIIII I I I• iI IH I I I I I I I MARTIN W. HANSON rfs-_711 � f I I n X it I i - - - MEN I I I I • • CLA KAM45, OREGON,1 L�==y� \ I- - -1 - �- - -I- (f!a i1)} • 10' MAX SPAN• 515' PLYWOOD DECK WIN I 104 1 IV 7I I SHEET METAL SCREWS OVER `.,/)� J " 11 \ / I • • AREA INDICATED ON PLAN ' OF Og 1 - I I • - c- - AI 8005250-54 METAL STUDS AT Ts6' o.c_,ALIGN WITH WALL STUDS - 0o — �" PROJECT #16010 — ✓tel I / \ I • • FCs. INSULATION { ::+ ' l' METAL CEILING STUD LOAD CHART o J JAN. — • • - , `� r' MAX.SPAN la �► MAX_SPACING 16' q 0 +>►� ,MAX.POINT LOAD 315 LES/STUD co 0 111 tii _ _ Iy ' � - 1 � � � �., yol �; ,;40,. ' I 1 1 ! _1 _ r -- _ --J ___ 5/S' GYP.BIRD. ! SUSPENDED CEILING W I. I- 3625131-33 METAL STUDS AT 16' O.G. 50AP PAPER TOWEL SAN.NAP. PAPER TOWEL/ RECESSED ri D€SPENSER DISPENSER DISPENSER DISPENSER/ TOWEL-�— IDISPENSER '�'�h 1 Ixlmmmmmmm•- - - — I 11 q• ui C15 El i I , .11,3=i t I I I_ —ii - I — I I m�1�1��1�.1�1� — -1-- ---\"\—\/ Cmi) • F I I I I I GYP.BRD. ! 5/8' GYP. BRD_ — ' — — [ I I I 1....---.....‘\ LL I CI- = - i I CENTER LINE OF STUD - F 1 Zj - S Cl • - •• �. 3-1/2'F.G. INSULATION `r D � a / O M 11 1 I 4' RIBBER BASE-TIP. E XCA 6' MIN. BASE ". � �' � � \ I I I IATTACH BOTTOM TRACK TO 42 yy SEE FINISH SCHEDULE WOMEN p I ^C (((®)}1 it FLOOR WITH POWDER DRIVEN >J illi19 V V O I v f G N \ ` I I - • • - FOR MATERIAL ANCHORS AT i2' O.C. 1 05 FINISH FLOOR \ SEAT COVER TOIL.PAPER/ GRAB BAR MIRROR a et 11 • P'' ' F1NIS1-1 FLOOR-TOP OF SLAB DISPENSER SEAT COV. DISPJ • N SAN.NAP. la REST ROOM SIDE OFFICE SIDE DISPOSAL O°' o'n I I I I I .L: f,4 (.5,,;LI 1 RR DEMO PLAN " ORR EXPANSION CEILING DEMO PLAN " s REST ROOM WALL SECTION ACC. - MOUNTING HEIGHTS �. vw, N.4- A-3 A-3 SCALE 1/4"= 1'-O" SCALE 1/4"= 1'-0" CD �A-3 SCALE �" = 1'-0" A-3 NOT TO SCALE E'+ %Dv:, _ _ 1111111I� IVIn �,M Sg I11/N I 11 I �� "" Q NEW GYP 60ARD CEILING .�“p•1 tfl-I w NEW TOILET PARTITION DOOR AND LED Fl TUBE Q �^ NEW CT O MATCH EXISTING MEN - RAC° HEAD `n ���V�' FWALLS TO N-TILE E-TILE ((( })). • • MATON EXISTING 104 �n IY I / 13 \xx xxx xxx x x x xx EXHAUST I O RELCATE MOP 51r3C • FAN I' �1 `� La H INSTALL FFA RR PARTITIONS ❑ J ❑ — I �' 6' 6' a WAINSCOT RR PARTITIONS `� • • 2'-0' u 1( 1v LITE KIT WHERE SPECIFIEDIll ------- .JAN. .14iir_ii„. 4.1,___ , x RELOCATED a _. ) r�LocA11 Z FIXTURE / EXISTIISs VCT 1 1 1 ri DRII�ING ■�������� _ 4 1' 1 I / .....` U D �. G A FoucNrdNS i�1111C.�11 °Q I 1 II v nrA. a 4 a i�iiii=ii ,�u, I _i f j , ' • I CD--1:-^. 5 �CXXX�CXxxxYti _ , , - a ti / — T 0 � �'. RETAIN ALL EXISTING FINISHES AND � `" 7 •^ x ��� � � NEW PLAM �:� E,��� U MATCH EXISTING FOR NEW FINI51 IES. VANITY TOP �C 1 O ice\ X i- . _ 1. M.a E� � �, TO MATCH NEW RR C'> -If I ADDITIONAL SWITCH Q O fo) ExISTING - 1 . INN ■ N ■� - 8AR LIGHT u, \ GANG LOGATIO N x 0 u z {� X PATCH IN NEW X X NEW TOILET FLOOR TILE TO �C AND LED • \ u, 4 x MATCH EXISTING. FIXTURE 4 - - E-TILE [N-TILE • O P X x 110,J ',t U Z N=W DOOR • Ase • ELECTRICAL F xi NEW PARTITION WITH CLOSER kU Cf) d u 3' 0' POOR • FAN y • \ Ill D OR J-BOX WOMEN WALL TILE TO • -ElY �7 (r�))51 O S Cr) MATCH EXISTING ON AND LED I p F- 105 ALL NEW WALLS FIXTURE AND LED - • FIXTURE • UNDERCUT DOOR A m @ aia h REQUIRED TO CLEAR m v .o an FLOOR FINISH 1 I 1 17. . . hi 2 ' ' EXPANSION PLAN N CD4 RR EXPANSION CEILING PLANCD 6 MOUNTING HEIGHTS A-3 SCALE 1/4"= 1'-0" A-3 SCALE 1/4"= 1'-0" A-3 SCALE 1/2" = 1 -O Cip .....43eZ P114 W 4 .i.4 1 ,,.r o w .- c a.... U -i e= - w.4, a� o �o W O U wU � W CONSTRUCTION LEGEND ul x I I a � ° I , EXISTING TO REMAIN C EXISTING TO BE REMOVED REVISION enrommanom w NEW STANDARD WALL © NEW STANDARD WALL WITH INS. 1. �. 2. 3. 07 EXISTING ELECTRICAL TO REMAIN SPECIAL OUTLET 4- -e DUPLEX RECEPTACLE / TELJDATA MUD RING WITH PULL STRING 5. 41) FOURPLEX RECEPTACLE a ELECTRICAL PANEL 6. D@ DEDICATED OUTLET Q POWER J-BOX ® FLOOR MONUMENT W/SERVICES SHOWN 8. 8. CEILING LEGEND 2 X 4 FLUOR.FIXTURE R.M.T. ><„ PARABOLIC LENSE TILE • SPRINKLER HEAD DATE: 1115116 mai2 X 4 FLUOR.FIXTURE €4 EXIT SIGN(LED RED) ►IIIPARABOLIC LENSE/STEADY BURN BALLIST cum HORN/STROBE FIRE ALARM(WALL MOUNTED) PERMIT/BID I j SURFACE MOUNTED 1 X 4 FLUORESCENT FIXTUREsi STROBE FIRE ALARM(WALL MOUNTED) • " RECESSED INCANDESCENT LIGHT ON RHEOSTAT OW.) rls ) HORN/STROBE FIRE ALARM(CEILING MOUNTED) SUPPLY DIFFUSER IL®II) STROBE FIRE ALARM(CEILING MOUNTED) Al RETURN DUCT co FIRE EXTINGUISHER IN RECESSED CAB. Q .,6i._ 3 THERMOSTAT ® FIRE E)CTINGUISHER-SURFACE MOUNTED ® EXHAUST FAN