Report (97) ( ks 1 � ?x�
Bend Office (541)330-9155
Geotechnical Office (503)601-8250
Carlson Testing, Inc. Eugene Office (541)345-0289
Salem Office (503)589-1252
Tigard Office (503)684-3460
Special Inspection
FINAL SUMMARY LETTER
Date: August 31,2017
Job#: T1701930.A
City of Tigard
13125 SW Hall Blvd
Tigard,OR 97223-8199
Attn: Building Division
Re: Project Name: 10BP126—PacTrust Voluntary Seismic Upgrade—Building 14
Address: 16100 SW 72nd Ave—Tigard, OR
Permit#: BUP2017-0022&BUP2017-00197
Per Chapter 17, Section 1704.1.2 of the International Building Code(IBC),we have performed special inspection of the following
item(s)per our inspection reports only:
Adhesive Anchors
The non-compliance (NC) items recorded for each of the above inspection categories, as listed on the non-compliance report,
have been either repaired and re-inspected by CTI for compliance or reviewed and accepted by the engineer of record for the
project in the"As-Built Condition"or through an RFI.
The issuance of this final report is based on the engineer's acceptance of the NC items not specifically re-inspected by CTI. CTI
did not provide any additional review or re-inspection of those items beyond the inspections that initially generated each of these
individual items on the non-compliance list. The engineer of record has provided the acceptance of the non-compliance items
and as-built conditions.
All requested inspections and tests were performed and reported according to the requirements of project documents and to the
best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and
applicable workmanship, provisions of the State Building Code and Standards, as well as the structural engineer's design
changes,approvals and verbal instructions.
Our construction inspection and testing services were provided and intended to help reduce the risk of construction defects,
deficiencies or omissions that arose during and after construction. Our services do not constitute a warranty or guarantee of any
type. Even with diligent construction monitoring and testing, construction defects, deficiencies or omissions in the contractor's
work may exist. It is the contractor's responsibility to perform their work in accordance with the approved construction
documents,
CTI has provided its professional services with the degree of care and skill currently exercised under similar circumstances by
members of its profession in the same locale. Statements made in our reports are based on technical judgments and should not
be construed to be conclusive representations of fact. Our reports pertain to the material tested/inspected only.
CTI's services did not include responsibilities related to determining,supervising,implementing or controlling the means,methods,
techniques,sequences or procedures of the construction or evaluating or reporting job conditions related to health,safety or
welfare.
Information contained herein is not to be reproduced, except in full,without prior authorization from this office. If there are further
questions regarding this matter please do not hesitate to contact this office.
Respectfully submitted))
CAR N STIN9ANC.
/
n W. th\
Project Manager
SW Ujng
cc: PacTrust—John Wiitala JOHNW@PACTRUST.COM
City of Tigard Building Division—Walter'Chip' Barnett EMAILED
MHP Structural Engineers—Eric Berkes EBERKESr41MHPSE.COM
Marvin&Sons Construction Inc—Bob Marvin MARVINANDSONS@COMCAST.NET
P:\Projects\Genera1120171T1701930A\08-31-17 Final letter.doc Updated 11/30/11
Carlson Testing, Inc.
Incompleted Items List (NCL)
Aug 31,2017
T1701930.A
Project Name: 1OBP126 - PACTRUST VOLUNTARY SEISMIC UPGRADE - BUILDING 14
Project Address: 16100 SW 72ND AVE PORTLAND OR
Permit No: , BUP2017-00222 & BUP2017-00197
P.O.No: Project Manager. STEVEN W. LEACH
Item# Insp. Date Item Description Compliance CTI Sign-Off Date
Corrected
1 JB 07/10/2017 NO PERMIT ISSUED YET. PERMITS PROVIDED. STEVEN W. LEACH 08/31/2017
2 JB 07/10/2017 NO CITY APPROVED DRAWINGS AVAILABLE. APPROVED DRAWINGS NOW ON STEVEN W. LEACH 08/31/2017
SITE.
CC:PACTRUST - JOHN WIITALA
CITY OF TIGARD BUILDING DIVISION - WALTER 'CHIP' BARNETT
MHP STRUCTURAL ENGINEERS - ERIC BERKES
NORTHWEST STRUCTURAL SERVICES INC - SCOTT CHITWOOD
MARVIN & SONS CONSTRUCTION INC - BOB MARVIN
NORTHWEST STRUCTURAL SERVICES INC - SCOTT CHITWOOD
Page: 1