Loading...
Report (88) 4 lc LkA-k J\)l-i UPVt l 1 1 N t . Gamewell 1100 Series 1r �IFIRE CONTROL INSTRUMENTS APR 2 5 2016 by Honeywell t }' ' . � Description Compact Analog Addressable The Gamewell-FCI, 7100 Series fire alarm control panel is Fire Alarm Control Panel a multi processor-based, analog addressable system. The control panel is a compact, yet expandable, platform. Intended for commercial, industrial and institutional instal- lations, the 7100 Series is ideal for life safety and property protection fire alarm applications. The basic 7100 Series control panel provides one analog gap addressable Signaling Line Circuit (SLC), whether sup- ports up to 99 analog addressable sensors, as well as sup- porting up to 98 addressable monitor modules and/or control points, totaling 197 addresses. The 7100 uses an advanced protocol that ensures an almost instant response to events while at the same time suppressing nuisance alarms. The system may be programmed with the CAMWorksTM 7100 Series programming utility tool or configured through a compre- Features hensive set of intuitive, secure password-protected, front- - • Listed under ANSI/UL®Standard 864 9th Edition. panel programming options. This important feature allows • IBC Seismic Certified. the system to quickly adapt to any future requirements due • 120 or 240 VAC(optional) input line voltage. to changes in occupancies, building remodels, or other • Front panel programming with day/night sensitivity contingencies. adjustments. • 80-character alpha-numeric display. The sophisticated circuitry and powerful analog software • One Style 4(Class"B")signaling line circuit. Style 6 enables the 7100 Series fire alarm control panel to read (Class"A")with optional CAOM Module. the specific sensitivity level of each sensor and compen- • Two Style Y(Class"B")regulated notification appliance sate for changes due to age, dust accumulation or other circuits rated for 1.5 amp each. Style Z(Class"A")with environmental factors. The 7100 incorporates the option®I CAOM Module. • Gamewell-FCI Listed Integrated Sensitivity Testing (LIST) FM/UL®Listed for Pre-action/Deluge with optional which meets NFPA 72 sensitivity testing and maintenance MCOM Module. • Periodic trouble reminder. requirements. The LIST testing allows substantial savings • Individual sensor drift compensation. in both maintenance and service while eliminating nui- • Dual-stage maintenance alerts("dirty"and"very dirty"). sance alarms. • Multilevel sensor sensitivity adjustments(front panel programmable). The Model 7100-1D features an integral Digital Alarm • Alarm verification per individual sensor. Communicator Transmitter (DACT) with all popular trans- • Positive alarm sequence for sensors or monitor mission formats and a 16-digit telephone number field. It is modules. 8-digit Carrier Information Code (CIC) compliant and also continued on the next page prevents "dialer-runaway" in the event of intermittent sys- tem faults. The 7100-1D is UL Listed for Remote Station, Proprietary, and Central Station fire alarm systems. It SIGNALING allows ample space for wiring and room for batteries up to 12 A/H capacity. ® ® MEA I LISTED APPROVED Approved ITHE VMC CIFICIUP CAMWorks° is a trademark of Honeywell International,Inc. S1869 3003549 FDNY 6911-1703:0116(Non-High Rise)Reference Certificate Microsoft®Word@ is a registered trademark of Microsoft@ Corporation. COA#s 307.99-E 6911-1703:0118(High Rise) of compliance UL®is a registered trademark of Underwriter's Laboratories Inc. 307-99-E Vol.II 7300-1703:0106(LCD-7100) VMA-45894-02C (Revision 1) ISO 9001 GAMEWELL-FCI row"":. 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2015 by Honeywell International Inc. All rights reserved. www.gamewell-fc1.com 9020-0466 Rev.N page 1 of 3 J t Optional Accessories Features (Continued) LCD-7100 • Four levels of system access using six digit passwords The LCD-7100 remote serial display offers an 80-character with up to five user passwords per Level. alphanumeric readout for the remote display of all system • Duplicate and extra address indications. events. It duplicates all the information on the 7100 Series • March time(60 or 120 BPM)/temporal pattern/coded panel display and provides key switch protected functions fours/California Code/user-defined zone coding. such as System Reset, Alarm Acknowledge, Trouble • Cross zoning. Acknowledge, Signal Silence, and Drill Test. • System configuration programming and 280 event log LEDs on the LCD-7100 indicate Alarm, Supervisory, Sys- stored in non-volatile memory. tem Trouble, Power Fault, Systems Silenced, NAC#1, and • Upload/downloadFarestart withsequential of panelrestartfigdelay. • of configuration between panel NAC#2 Silenced conditions. and CAMWorks program (password protected feature). The LCD-7100 can be surface or semi-flush mounted on a • Up to 64, 7100 panels in the E3 Broadband network standard four-gang electrical box. It can be installed up to with an optional INI-7100 Module. 3,000 feet(914.4 m)from the main control panel.The 7100 Series fire alarm control panel supports up to five remote LCD-7100 annunciators using one pair of twisted, non- shielded 18 AWG min. wire or serial communication and Specifications uses another pair of 16 AWG min. for operating voltage. (For additional information, refer to the LCD-7100 data Primary Input Power 120 VAC, 50/60 Hz @ 2.0 amps. sheet, Part Number: 9020-0486). or 240 VAC,50/60 Hz @ 1.0 amp RAN-7100 Output Power 3.335 amps. @ 24 VDC(total) Non-resettable Power: 1.0 amp max. The RAN-7100 maintains the same character display as Resettable Power: 1.0 amp max. the 7100 Series. The RAN-7100 is mounted in a RAN2-BB 1.0 amp max. from both power backbox for surface or flush mounting retrofits. circuits (For additional information, refer to the Gamewell Retrofit Two Notification • Kits Data Sheet, P/N: 9020-60678). Appliance Circuits: 1.5 amp each @ 24 VDC Current: Supervisory Alarm CAOM 7100-1 (One SLC) 0.065 amp 0.085 amp The Class"A"Optional Module(CAOM)allows Style Y and 7100-1D Z(Class"B"and"A")operation for both Notification Appli- (One SLC w/DACT) 0.075 amp 0.095 amp ance Circuits and allows Style 4 and 6(Class"B"and"A") LCD-7100 0.050 amp 0.075 amp for the Signaling Line Circuit. It also provides a disconnect INI-7100-UTP,-FO 0.040 amp 0.040 amp switch for the signaling line circuit and a common discon- Operating nect switch for both notification appliance circuits. Temperature: 32°- 120° F(0°-49°C) MCOM Relative Humidity: 93%(non-condensing) The Municipal Connection Option Module(MCOM)pro- Battery Charger vides three choices of outputs. It can be configured as a Capacity: 31 A/H (Cabinet accommodates Municipal Circuit(City Box)output. It may also be set to 12 A/H size batteries) serve as a Reverse Polarity output with a nominal voltage Relay Contacts:Trouble Relay Form"C",2 amps. @ 24 VDC output of 24 VDC at 0.012 amp maximum alarm and (resistive) supervisory current.The MCOM's third option provides a releasing solenoid output rated at: • 24 VDC nominal voltage. • 0.005 amp supervisory current. • 0.710 amp maximum alarm current. • 2 ohms maximum line resistance. PTRM The Printer Transient Module(PTRM)provides RS-232 Isolator/Transient protection for the 7100's RS-232 port (BSM connector J2). It is used in conjunction with a serial printer applied to the RS-232 port for permanent record keeping. INI-7100 The Intelligent Network Interface Module allows the 7100 Series fire alarm control panel to become the platform of a peer-to-peer,token ring, self-regenerative network corn- prised of up to 64, 7100 panels. ( GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0466 Rev.N page 2 of 3 www.gamewell-fci.com 4 Ordering Information Ordering Information (Continued) Systems Replacement Parts Part Number Description Part Number Description 7100-1-PNL 7100 Addressable FACP, 1 SLC mounted BSM-7100-1 Replacement board for 7100-1 in the 7100-CAB enclosure, red BSM-7100-1D Replacement board for 7100-1D 7100-1D-PNL 7100 Addressable FACP w/DACT, One BSM-7100-2 Replacement board for 7100-2 SLC mounted in 7100 CAB enclosure, BSM-7100-2D Replacement board for 7100-2D red Seismic Battery Bracket Kits Basic Kits 90516 7100-Slim 7 A/H Seismic Battery 1100-1313 Basic System Kit, 2 SLC, 240 VAC Bracket kit Optional Modules E3 B-Slim 7 A/H Seismic Battery LCD-7100 Remote Serial Annunciator, LCD Display Bracket Kit 90517 7100-Slim 12 A/H Seismic Battery (80 character). Dimensions: 4.25" H x 8.25"W x 1.90" Bracket Kit E3 B-Slim 12 A/H Seismic (43 H x 37 W x 7.7 D cm) Battery Bracket Kit 90518 NetSOLO RAN-7100 Remote Series Annunciator, LCD Display 7100 7 A/H Seismic Battery (80-character). Braccketket Kit For additional information on the Seismic Battery Brackets, Dimensions: 10"Wx 5 1/4" H x 2 7/16" D refer to the following documents: (251/4 W x 131/3 H x 6 9/10 D cm) CAOM Class A Option Combination Module with • Seismic Battery Bracket Installation Guide, P/N: 53839 disconnect switches for both signaling • E3 Series Cabinets Data Sheet, P/N: 9020-0649 line circuits and notification appliance circuits. MCOM Municipal Connection Option Module for local energy city box reverse polarity sig- naling, or releasing solenoid. PTRM Printer Transient Module. INI-7100-FO Intelligent Network Interface Module, Fiber-Optic. INI-7100-UTP Intelligent Network Interface Module, Unshielded, Twisted-Pair. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9020-0466 Rev.N page 3 of 3