Loading...
Report (91) NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. . FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • "Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology"Listed Voltage Range". Table 1: Ratings Per UL 1971 Table 2:dBA Ratings for 12 VDC and 24 VDC Series AS/ Input Regulated AH 12 and 24 VDC Audible Model Strobe Voltage Voltage Range Reverberant Number VDC VDC/FWR Candela(cd) Anechoic Description Volume Per UL 464 dBA AS-24MCW 24 16.0-33.0 15/30/75/110 @ 10 ft. @ 10 ft. AS-24MCCH 24 16.0-33.0 115/177 High 91 99 AS-241575W 24 16.0-33.0 15(75 on Axis) Continuous Horn Medium 88 95 AS-121575W 12 8.0-17.5 15(75 on Axis) Low 83 90 AS-24MCC 24 16.0-33.0 15/30/75/95 High 87 99 - AS-24MCWH 24 16.0-33.0 135/185 Code 3 Horn Medium 84 95 • ASWP-2475W 24 16.0-33.0 75 @-31°F Low 79 90 - Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd High(99) 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med(95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low(90) 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Wall Mount Audible Audible 12 VDC Models Strobe Table 4: Average Current*(AMPS)For Series ASWP# High dBA Medium dBA Low dBA AH-12 AS-121575W Voltage Setting Setting Setting 12 vdc 0.163 0.260 (99)dBA (95)dBA (90)dBA High(99) 24.0 VDC 0.128 0.105 0.098 dBA UL max* 0.192 0.320 - UL Max 0.168 0.155 0.150 Med(95) 12 vdc 0.076 0.195 - dBA UL max* 0.108 0.275 *RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33v Low(90) 12 vdc 0.039 0.175 for 24v units). For strobes the UL max current is usually at the minimum dBAUL max* 0.058 0.265 listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings,see installation instructions. cY . Wiring Diagrams* SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM PRECEDING + +. APPLIANCE MODULES APPLIANCE - 1011 OR EOLR OR FACP e Audible NAC Or , DSM#t Strobe NAC Cir. F .m t IGINIF m Audible NAC Cir I DSM#2 SERIES AS&ST APPLIANCES SYNCHRONIZED WITH Strobe NAC Cir. ,:B+ tiirNWHEELOCK POWER SUPPLIES Audible NAC Cir I DSM#3 -I P -B■ Sync i_m_z AS [ © Strobe NAC Or. `0 - OUTPUTS \ EOLR Facuss DSM Interconnecting wiring shown.Maximum of A ORAS © twenty(20) OR 2-CLASSC * For detail using DSM Sync Module refer to Data Sheet A S3000 or Installation Instructions P83177 for DSM. For P wiring informationon the power supplies refer to Installation AS < 0 Instructions P84905 for Wheelock Power Supplies. Series PS Power Supplies SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A"NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE °SAL=rN M°°SLE @svN ! : :. IIIIIIIIIIII II ti I' 1.1 IG NPL ,' AU°e LE o uT z �I �I �/ �/ 11_, RETURN CIRCUIT Specifications and Ordering Information j Sync DSM Agency Approvals Model Number 'Order Strobe Non-or Wheelock 24 12 Wall Ceiling Mounting Options*** Code Candela Sync Power VDC VDC Mount Mount Supplies UL MEA CSFM FM BFP AS-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCW-FW 9025 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCWH-FR _3468 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X - AS-24MCWH-FW 3469 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X - AS-241575W-FR 7405 15(75 on Axis) X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-121575W-FR 7410 15(75 on Axis) X X - X X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X - AS-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X - ' AS-24MCCH-FW 3467 115/177 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X - ASWP-2475W-FR** 9012 75 @-31°F X X X - X - I (see Data Sheet S9004) X X X X X AH-24-R 7892 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-24-W 7893 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-12-R 7891 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-12-W 7894 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-24WP-R** 7416 - X X X - X X K X X X - X AH-12WP-R** 7415 - X X - X X X K X X X - X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet S7000 for Mounting Options. Note:Models are available in either Red or White.Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection • Service.The Series AH Audible shall be UL Listed under Standard 464(Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP). The audible portion of the appliance shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal(Code 3)audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified,the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required(e.g.ADA compliance). When synchronization is required,the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed),the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang,double-gang,4-inch square, 100mm European type backboxes,or the SHBB Surface Backbox. If required,an NATP (Notification Appliance Trimplate)shall be provided. All notification appliances shall be backward compatible. - i WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S8100 AS/AH 06/11 NJ Location 273 Branchport Ave. Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com Cooper Notification is Wheelock" 1,, 3103 SAFEPATH' WAVE " COOPER Notification