Loading...
Report (90) NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR " APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. ' FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • "Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology"Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP-Wall Mount Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP Wall Mount 24VDC 24VDC * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage(16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2:Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Wiring Diagrams # Horns AH, NH, HS SERIES RSS/RSSP APPLIANCE Motor Bells MB-G6/G10 FROM + + TO NEXT PRECEDING -APPLIANCE Speakers ET-1010/1080, E70, ET70 APPLIANCE,SYNC MIMI OR EOLR MODULE,POWER 111111 Chimes CH70 SUPPLY OR FACP a do SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS"A"NAC CIRCUIT SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM DSM#1 STROBE + Sync ® ® NAC SYNC Strobe NAC Cir. –a+ CIRCUIT F OUT 0+OUT1 —0 i� ICZIKO DSM#2 ', �I+IN1 _ A � � ji MINUS i Strobe NAC Cir. _ 0 AUDIBLE 'MINUS2 111 DSM#3 '°+ ' ® ® ®II+IN2 P $y+TROB © N NAC E ��*OUT Strobe NAC Cir._ + CIRCUIT RETURN DSM Interconnecting wiring shown.Maximum of twenty(20) t STROBE/PLATE ASSEMBLY AUDIBLE&VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM APPLIANCE PRECEDING - - OR EOLR APPLIANCE,SYNC III' SERIES RSS/RSSP APPLIANCES SYNCHRONIZED MODULE,POWER WITH WHEELOCK POWER SUPPLIES SUPPLY OR FACP Series PS Power Supplies STROBE AUDIBLE HS OUTPUTS EOLR 1-4 4-CLASS —� A B. HS `/ \ STROBE/PLATE ASSEMBLY OR AUDIBLE&VISIBLE APPLIANCE OPERATE INDEPENDENTLY C z-CLASS "A' J FROM + + TO NEXT PRECEDING APPLIANCE OR _ APPLIANCE FACP OR EOLR a HS 110 Series PS Power Supplies FROM + 1 r +TO NEXT - PRECEDINGy--I ——— STROBE OR STROBE,SYNC- -— I I 1 r—— - EOLR MODULE,POWER I 1 SUPPLY OR FACP 1111 STROBE APPLIANCE " For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Wheelock Power Supplies. Specifications and Ordering Information Order Wall Ceiling Non- Strobe 24 12 Color Color Square Agency Approvals Model Mounting Options*** or Code Mount Mount Sync Candela VDC VDC RED WHITE y Round UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-AR**** 9773 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15(75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSSWP-2475W-FR** 9013 X - X 180@ 77°F X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X - 75@-31°F - RSSWP-2475W-FW** 3034 X - X 180@ 77°F X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X - 75@-31°F :RSSP-121575W-FR 7798 X - X 15(75 on Axis) - X X - D,E,Z Square X - X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15(75 on Axis) - - X - D,E,Z Square X X X X X RSSP-24MCWH-FR 9482 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X - - All models sync with Wheelock DSM or Wheelock Power Supplies. #Models are available in either Red or White.Call Customer Service for Order Code&Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. ****"A"stands for Agent Lettering. Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals.The Series RSS shall meet • and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP).When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design.Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required(e.g.ADA compliance). When synchronization is required,the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate.The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang,double-gang, 4-inch square, 100mm European type backboxes,or the SHBB Surface Backbox.If required,an NATP(Notification Appliance Trimplate)shall be provided.An attaching cover plate shall be provided to give the Appliance and attractive appearance.The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock,Inc.standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S0410 RSS/RSSP 07/11 NJ Location 273 Branchport Ave. Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com 101.1 Cooper Notification is Wheelock° 1,, ori' SAFEPATH` WAVYPbstat COOPER Notification