Report (89) ti Optional Accessories Features (Continued) LCD-7100 • Four levels of system access using six digit passwords The LCD-7100 remote serial display offers an 80-character with up to five user passwords per Level. alphanumeric readout for the remote display of all system • Duplicate and extra address indications. events. It duplicates all the information on the 7100 Series • March time(60 or 120 BPM)/temporal pattern/coded panel display and provides key switch protected functions fours/California Code/user-defined zone coding. such as System Reset, Alarm Acknowledge, Trouble • Cross zoning. Acknowledge, Signal Silence, and Drill Test. • System configuration programming and 280 event log LEDs on the LCD 7100 indicate Alarm, Supervisory, Sys- stored in non-volatile memory. • Fanrestart withsequential restartdelay. tern Trouble, Power Fault, Systems Silenced, NAC#1, and • Upload/download of panel configuration between panel NAC#2 Silenced conditions. and CAMWorks program(password protected feature). The LCD-7100 can be surface or semi-flush mounted on a • Up to 64, 7100 panels in the E3 Broadband network standard four-gang electrical box. It can be installed up to with an optional INI-7100 Module. 3,000 feet(914.4 m)from the main control panel.The 7100 Series fire alarm control panel supports up to five remote LCD-7100 annunciators using one pair of twisted, non- shielded 18 AWG min. wire or serial communication and Specifications uses another pair of 16 AWG min.for operating voltage. (For additional information, refer to the LCD-7100 data Primary Input Power 120 VAC,50/60 Hz @ 2.0 amps. sheet, Part Number: 9020-0486). or 240 VAC,50/60 Hz @ 1.0 amp Output Power 3.335 amps. @ 24 VDC(total) RAN-7100 Non-resectable Power: 1.0 amp max. The RAN-7100 maintains the same character display as Resettable Power: 1.0 amp max. the 7100 Series. The RAN-7100 is mounted in a RAN2-BB 1.0 amp max.from both power backbox for surface or flush mounting retrofits. circuits (For additional information, refer to the Gamewell Retrofit Two Notification Kits Data Sheet, P/N:9020-60678). Appliance Circuits: 1.5 amp each @ 24 VDC CAOM Current: Supervisory Alarm 7100-1 (One SLC) 0.065 amp 0.085 amp The Class"A"Optional Module(CAOM)allows Style Y and 7100-1D Z(Class"B"and"A")operation for both Notification Appli- (One SLC w/DACT) 0.075 amp 0.095 amp ance Circuits and allows Style 4 and 6(Class"B"and"A") LCD-7100 0.050 amp 0.075 amp for the Signaling Line Circuit. It also provides a disconnect INI-7100-UTP,-FO 0.040 amp 0.040 amp switch for the signaling line circuit and a common discon- Operating nect switch for both notification appliance circuits. Temperature: 32°-120° F(0°-49°C) MCOM Relative Humidity: 93%(non-condensing) The Municipal Connection Option Module(MCOM)pro- Battery Charger vides three choices of outputs. It can be configured as a Capacity: 31 A/H(Cabinet accommodates Municipal Circuit(City Box)output. It may also be set to 12 A/H size batteries) Alarmserve as a Reverse Polarity output with a nominal voltage Relay ant Trouble Relay Contacts: Form"C", 2 amps. @ 24 VDC output of 24 VDC at 0.012 amp maximum alarm and (resistive) supervisory current.The MCOM's third option provides a releasing solenoid output rated at: • 24 VDC nominal voltage. • 0.005 amp supervisory current. • 0.710 amp maximum alarm current. • 2 ohms maximum line resistance. PTRM The Printer Transient Module(PTRM)provides RS-232 Isolator/Transient protection for the 7100's RS-232 port (BSM connector J2). It is used in conjunction with a serial printer applied to the RS-232 port for permanent record keeping. INI-7100 The Intelligent Network Interface Module allows the 7100 Series fire alarm control panel to become the platform of a peer-to-peer,token ring,self-regenerative network com- prised of up to 64,7100 panels. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0466 Rev.N page 2 of 3 www.gamewell-fci.com J i Ordering Information Ordering Information (Continued) Systems Replacement Parts Part Number Description Part Number Description 7100-1-PNL 7100 Addressable FACP, 1 SLC mounted BSM-7100-1 Replacement board for 7100-1 in the 7100-CAB enclosure, red BSM-7100-1D Replacement board for 7100-1D 7100-1D-PNL 7100 Addressable FACP w/DACT,One BSM-7100-2 Replacement board for 7100-2 SLC mounted in 7100 CAB enclosure, BSM-7100-2D Replacement board for 7100-2D red Seismic Battery Bracket Kits Basic Kits 90516 7100-Slim 7 NH Seismic Battery 1100-1313 Basic System Kit,2 SLC,240 VAC Bracket kit Optional Modules E3 B-Slim 7 A/H Seismic Battery Bracket Kit LCD-7100 Remote Serial Annunciator, LCD Display 90517 7100-Slim 12 NH Seismic Battery (80 character). Dimensions: 4.25"H x 8.25"W x 1.90" Bracket Kit E3 B-Slim 12 A/H Seismic (43 H x 37 W x 7.7 D cm) Battery Bracket Kit 90518 NetSOLO RAN-7100 Remote Series Annunciator, LCD Display 7100 7 NH Seismic Battery (80-character). Braccketket Kit For additional information on the Seismic Battery Brackets, Dimensions: 10"W x 5 1/4" H x 2 7/16" D (25refer to the following documents: 1/4 W x 13113 H x 6 9/10 D cm) CAOM Class A Option Combination Module with • Seismic Battery Bracket Installation Guide, P/N: 53839 disconnect switches for both signaling • E3 Series Cabinets Data Sheet, P/N: 9020-0649 line circuits and notification appliance circuits. MCOM Municipal Connection Option Module for local energy city box reverse polarity sig- naling, or releasing solenoid. PTRM Printer Transient Module. INI-7100-FO Intelligent Network Interface Module, Fiber-Optic. INI-7100-UTP Intelligent Network Interface Module, Unshielded,Twisted-Pair. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9020-0466 Rev.N page 3 of 3 FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power 1 Trouble Output Local Fire Control (Alternative to notification circuit trouble.) . Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification (0° to 49° C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) the 5495 creates a trouble Indicator Lights condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 kS2 EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification Accessories: No. of inputs 2 AC input: 120 VAC at 2 amps SK-SCK Seismic Compliance Kit Input Output: 24 VDC at 6 amps configuration: 2 Class B or 2 _ Class A SILENTTip it This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350395 Rev F subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-7161 Phone: (800)328-0103, Fax:(203)484-7118.For Technical Support,please call 800-446-6444. www.silentknight.com