Loading...
Plans (130) /024011 StA) ',✓12 .r/ t.- Alpine, an ITW Company 8351 Rovana Cirde Sacramento,CA 95828 ALPINE' Phone:(800)877-3678(916)387-0116 IN/oM�hy Fax:(916)387-1110 AN sacseals@itwbcg.com Site Information: Customer. Truss Components of Oregon,Inc. Job Number. R_1115027 JobDescription: R_1115027 Address: City,State,Zip: Job Engineering Criteria: Design Code: IRC 2012 Design View Version: 18.01.00.3.23.8 JRef#: 1WD471750003 Wind Standard: ASCE 7-10 Wind Speed(mph): 120 Roof Load(psf): 25.00-10.00-0.00- Floor Load(pst): None 7.00 This package contains a job notes page, 1 truss drawings and 0 details. Item Seal* Truss 1 212.18.1702.57133 BG Ep PROp,. ��� Op �GINFF 'Q 19575 41 1.7 OREGON J 9 .i0.1aL�O� -V Renews 6190/2019 Printed 7/31/2018 5:11:05 PM 07/31/2018 ' Job Number: R 1115027 Ply: 4 SEAN:350945/T22 COMN Gust:R7175 JRef•.1WD471750003 • R_1115027 Qty: 1 FROM:BB DrwNo: 212.18.1702.57133 Truss Label: BG PBC / GWH 07/31/2018 I S , 4 Complete Trusses Required 5'393 93"14 13'3"15 17'4" 21'4"1 25'4"2 29'4"3 34'8" I 5,3„13 4,0„1 I A.0„1 4'Q,1 I 4,0„1 I 4,0„1 I 4,0„1 5'3"13 'I DRILLED BC DETAIL(side view) I'll E 1 (1"' 12 s D F • a 2” i� o G ro B H A I Els- I , r ia 1.1 IN ill _ — I I I 1 1 1 S \-1/2"holR Q P O N M L K J Pi k 34'8" 1 5713 401 401 40"1 I 401 I 401 I 401 5313 " I " I " I " " "5313 9314 13315 174" 2141 2542 2943 348 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def/CSI Criteria A Maximum Reactions(lbs) TCLL: 25.00 Wind Std: ASCE 7-10 Pg:25.0 Ct 1.1 CAT:II PP Deflection in loc Udefl U# Loc R /U /Rw I Rh /RL 1W TCDL: 10.00 Speed: 120 mph Pf:21.2 Ce:1.1 VERT(LL): 0.519 N 794 360 S 13549/689 /- /- I- /5.5 BCLL: 0.00 Enclosure:Closed Lu: - Cs:1.00 VERT(TL): 1.211 N 340 240 I 12760/634 /- /- /- /5.5 BCDL: 7.00 Risk Category:II Snow Duration:1.15 HORZ(LL): 0.126 J - - Wind reactions based on MWFRS Des Ld: 42.00 EXP:B HORZ(TL):0.294 J - - S Min Brg Width Req= 3.6 Mean Height:21.22 ft Code/Misc Criteria Creep Factor:2.0 I Min Brg Width Req= 3.4 NCBCLL:0.00 TCDL:6.0 psf Bearin s S&I are a rigid surface. Soffit 2.00 BCDL:4.2 psf Bldg Code: IRC 2012 Max TC CSI: 0.966 g Load Duration:1.15 MWFRS Parallel Dist:0 to h/2 TPI Std: 2007 Max BC CSI: 0.829 Spacing:24.0" C&C Dist a:3.47 ft Rep Factors Used:Yes Max Web CSI: 0.693 Members not listed have forces less than 375# FT/RT:2(0)/4(0) Maximum Top Chord Forces Per Ply(lbs) Loc.from endwall:Any Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): Wind Duration:1.60 WAVE,HS VIEW Ver:15.01.016.0522.21 A-B 450-8814 E-F 270 -5316 Specification for field condition: B-C 397-7785 F-G 332 -6555 One 1/2""diameter holes may be drilled through D-E 270-53 -H 391 -8815 one ply of bottom chord as shown. D-E 270- 6 5316 H H-I 4399 -8815 No repair required,provided that no grade limiting lumber Maximum Bot Chord Forces Per Ply(lbs) defects,such as wane,knots,or splits,exist within 12" Chords Tens.Comp. Chords Tens. Comp. of the drilled area. See drawing CAUSR7175 15309053 for lumber, A-R 8356 -425 N-M 6119 -309 plates,and other data not shown here. R-Q 8318 -423 M-L 7289 -366 Q-P 7284 -370 L-K 7289 -366 Construct the field repair or modification in accordance P-O 7284 -370 K-J 8318 -413 with the design and situation decribed above. O-N 6118 -311 J-I 8357 -415 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. R-B 686 -26 N-F 82 -1633 B-Q 54-1036 F-M 1568 -69 Q-C 1191 -53 M-G 68 -1401 �pPROfi C-O 72-1396 G-K 1195 -49 O`���� FS, 30 '3% D N 15684-1631 H-J 685 '22 ‘401111E.x`46 y E-N 3253 -156 19575 9 ;r dik I' 1/21 8 OREGON 1 4)n.20.14° '• Rp1. 1W VW Renews 6/30/2019 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! Truss Components of Oregon,Inc. **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS P.O.Box468 Trusses reuire extreme care in fabricating,handling,shipping,installingandbracing. Refer to and follow the latest edition of BCSI(Building CORNELIUS OR 97113 ComponentSafety Information,byTRI an SBCA)/ safety practices prior to performing these functions. Installers shall.provide to pora ( >357-2118 Ext bracing per BCSI.Unless noted Otherwtse,top chord shall have properly attached structural sheathing and bottom chord shall have a proppeerly attached riggid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3,B7 or B10, as applicatlle. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z fbr standard plate positions. Alpine,a division of ITW Buildl'n CComponents Group Inc.shall not be responsible for any deviation from this drawing,an failure to build the ANrrnN,. truss in conformance with ANSI/IP! 1,or for handling,shipping,installation and bracingof trrussesA seal oenthis ddrawin or cover page lisand this t this B indicateswBrewing acceptance structce of roesponsii gngofth B itresponsibilityner per design zuc.2hovlgil. The suiFability 8351 Rovana Circle se o ra ng for any structure the respons briny of the Building Sacramento,CA 95828 For more information see this job's general notes page and these web sites:ALPINE:www.alpineitw.com;TPI:www.tpinst.org;SBCA:www w.sbcindustry.com;ICC: ww.iccsafe.org