Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
• LEGEND 'N%l'4" INV INVERTER&DC DISCONNECT BLUE RAVEN SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 129'-7" AC AC DISCONNECT 800-377-4480 W W W.BLU ERAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC.V FIRE SETBACK Q EMT CONDUIT RUN w 14 J a (TO BE DETERMINED IN FIELD) 0 O I' o ZJ0) Q � � PV WIRE STRING Q ( •C Et L.Li CO) ❑ I 21 coo ~ 1z o o I PROPERTY LINE U O M O /V CO I �a w U U m ❑ ❑ ❑ 0 ❑ El El ❑ 4- 0 SCALE: 1/16"= 1'-0" 135' 6 [t Ok 2f. Of. S. Oic U - 0 JB 0 _ (1) 0Ofc Of. Ofc Of. .> 0 u) L ROOF ATTACHMENTS SHALL 0) BE SPACED NO GREATER 105'-6" / \ O 45 THAN 24" ON CENTER IN Q i-- N ANY DIRECTION WHERE / \ ft+ rx a o W LOCATED WITHIN 3' OFAw O •- = 0) I- ❑ ROOF EDGE, HIP, EAVE, OR z 0 0 0 cn RIDGE OSSC 3111 .5.3 ITEM L co c u 3.5 �n o - F o cd DRAWING BY Eric Thomas AC DISCONNECT TO BE LOCATED DATE WITHIN 10' OF UTILITY METER June 8, 2018 PROJECT NUMBER DC SYSTEM SIZE: 6.67 kW DC 51903766 ROOF TYPE: Comp Shingle X162'-8" _________________---•,\ SHEET NAME (23) Sunmodule Plus SW 290M Black PROPERTY PLAN Enphase IQ6-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 0 LEGEND \e'''' INV INVERTER&DC DISCONNECT BLUE RAVENO SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 ❑ AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION O HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF Fa_ JB JUNCTION BOX ANYONE EXCEPT III ❑ Ti ❑ L� B DISCLOSED S IN NOR SHALL IT BE IN WHOLE OR IN C COMBINER BOX PART TO OTHERS OUTSIDE 0 RECIPIENTS ORGANIZATION, Q EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE ,g� PV PV REVENUE METER EQUIPMENT,WITHOUT THE ERC VIC EAC aC ffC Ek ERC 12iC CAC C VIC ac U WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. O j FIRE SETBACK } (n O 0 ,g� JB I EMT CONDUIT RUN �jJ L1J at O 0- d- O �c c Vic c C I[gC C (TO BE DETERMINED IN FIELD) 0 Z O ZDrn UDr- PV WIRE STRING Q 0 t LU CO. 2 I- I- E o O I PROPERTY LINE U WU U m -) (/) . ' SCALE: 1/8"= 1-0" 0,�,/ 0 2 4 8 16 LL MP1 a O AZIMUTH:23° PITCH:142° TSRF:72% > . L 0 / \ L I- a) ROOF ATTACHMENTS SHALL Z L) N BE SPACED NO GREATER L ~ H N THAN 24" ON CENTER IN / \ 3 a 0 ANY DIRECTION WHERE6t2 _02 W U LOCATED WITHIN 3' OFA o o p` j ROOF EDGE, HIP, EAVE, OR z .� -a 00 } L RIDGE OSSC 3111 .5.3 ITEMqt+ - a Cr) o 3.5 DRAWING BY Eric Thomas AC DISCONNECT TO BE LOCATED DATE WITHIN 10' OF UTILITY METER FRONT OF HOME June 8, 2018 PROJECT NUMBER DC SYSTEM SIZE: 6.67 kW DC 51903766 ROOF TYPE: Comp Shingle SHEET NAME (23) Sunmodule Plus SW 290M Black SITE PLAN Enphase IQ6-60-2-US,----INVERTER PAGE NUMBER REVISION PV3 0 PV ARRAY STRUCTURAL CRITERIA ® 9 PV MODULE PV MODULE COUNT: 23 MODULESfi Iron Ridge XR10 PV RAIL # OF ATTACHMENT POINTS: 62 r i --_1 L RAVEN ARRAY AREA: Module Count X 17.51ft2=402.7ft2 ti N g N N l'-11" 48"MAX." ROOF AREA: 4060.9ft2 MAX. 1220 S.630 E STE.430 % OF ARRAY/ROOF: 9.9°i° ARRAY DETAIL, FRONT VIEW AMERICAN FORK,UT 84003 Scale: 3/8" = 1'-0" 800-377-4480 WWW.BLU ERAVEN SOLAR.COM ARRAY WEIGHT: Module Count x 501bs = 1150.OIbs ROOF TYPE: Comp Shingle DISTRIBUTED LOAD: Array Weight-Array Area=2.86 lbs/ftp • ROOF FRAMING TYPE: Manufactured Truss CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE RAFTER OR TOP CHORD SIZE: 2x4 USED FOR THE BENEFIT OF POINT LOAD: Array Weight_Attachments= 18.5Ibs/attachment RAFTER OR TOP CHORD SPACING: 24"O.C. Iron Ridge XR10 PV RAIL ANYONE EXCEPT CEILING JOIST OR BOTTOM CHORD SIZE: 2x4 BLUERAVENSOLAR NOR SHALL IT CEILING JOIST OR BOTTOM CHORD SPACING: 24"O.C. BE DISCLOSED IN WHOLE is IN PART TO ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C E ' RECIPIENTS ORGANIZATION, SITE CRITERIA 10" MIN - FlashFoot2 �- EXCEPTINCONNECTIONWITHTHE GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D —' ' SALE AND USE OF THE RESPECTIVE 1' 4" - -- EQUIPMENT,WITHOUT THE , WRITTEN PERMISSION OF IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL 10"MIN - MAX BLUERAVENSOLAR LLC. IRONRIDGE UNIVERSAL FASTENING OBJECT vllir --- 2'-8" MIN - FASTENING OBJECT PV MODULE FRAME .� - 's_____- 142 Q } o L c' 1'AF PV MODULE FRAME AmAx r 3' 10" MAX w Z O--r IRONRIDGE RAIL ; 0 IRONRIDGE RAIL I- Z 0 ' Q 0 I: A 2'-8" MIN Q 0 d W co I _ J O.. 3'-10"MAX 2 � � Z� LI 6o 11111. ARRAY DETAIL, SIDE VIEW 5O ' O 00 Scale: 3/8" = 1'-0" m O DETAIL, END CLAMP FRONT O DETAIL, MID CLAMP FRONT 0 II Scale: 6"= 1'-0" Scale: 6"= 1-0" 0_ Sunmodule Plus SW 290M Black PV MODULE 'L 0 cn Iron Ridge XR10 PV IRONRIDGE iLv RAIL 1— CDU CO N ,.„(Ni W (E)ROOF o 4„ I- MEMBRANE oc Ct ti) 3 0 � t 2 W o o O t j 0 Z a r� >- W .0 up .L co (0 I_s 0) 0 co 1 IRONRIDGE C/) d 7 I- 0 (s5._ FLASHFOOT 2.5" MIN. & ASSEMBLY DRAWING BY EMBED. Eric Thomas FLASHING DATE 5/16"STAINLESS STEEL LAG BOLT June 8, 2018 WITH 2-1/2" MIN. EMBEDMENT . AND FLAT WASHER PROJECT NUMBER 51903766 (E)BUILDING STRUCTURE SHEET NAME DETAIL, STANDOFF EQUIP. DETAIL O PAGE NUMBER REVISION Scale: 3" == 1 -0" PV4 0 MODULE SPECIFICATIONS Sunmodule Plus SW 290M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS • RATED POWER(STC) 290 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG. HIGH TEMP MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 11.5 A DC \Orr MODULE VOC 39.9 V DC STATE Oregon JUNCTION BOX MAX.CURRENT(ISC X1.25)= 14.4 A DC MODULE VMP 31.4 V DC CITY Tigard CONDUCTOR(TC-ER,(90°C))= 12 AWG BLUE RAVEN MODULE IMP 9.33 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 9.97 A DC ASHRAE EXTREME LOW TEMP(°C) -6 AMB.TEMP.AMP.CORRECTION= 0.96 VOC CORRECTION(%/°C) -0.31 °C ASHRAE 2%AVG. HIGH TEMP(°C) 32 ADJUSTED AMP.= 28.8 > 14.4 1220 S.630E STE.430 AMERICAN FORK,UT 84003 VMP CORRECTION (%/°C) -0.44 °C JUNCTION BOX TO MAX. SHORT CIRCUIT CURRRENT(ISC)= 11.5 ADC 800-377-4480 SERIES FUSE RATING 25 A DC SYSTEM ELECTRICAL SPECIFICATIONS CI R 1 CIR 2 CIR 3 CI R 4 CIR 5 CIR 6 COMBINER BOX MAX.CURRENT(ISC X1.25)= 14.4 A DC WWW.BLUERAVENSOLAR.COM ADJ. MODULE VOC @ ASHRAE LOW TEMP 43.7 V DC NUMBER OF MODULES PER MPPT 11 12 CONDUCTOR(THWN-2, (90°C)= 10 AWG CONFIDENTIAL-THE INFORMATION ADJ.MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 26.0 V DC DC POWER RATING PER CIRCUIT(STC) 3190 3480 CONDUCTOR RATING= 35 A HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF TOTAL MODULE NUMBER 23 MODULES CONDUIT FILL DERATE= 1 ANYONE EXCEPT MICROINVERTER SPECIFICATIONS Enphase 106-60-2-US STC RATING OF ARRAY 6670W DC AMB.TEMP.AMP. CORRECTION= 0.96 BBE DISC OSED IIN w OLE OR INT POWER POINT TRACKING(MPPT) MIN/MAX 22 - 48 V DC AC CURRENT @ MAX POWER POINT(IMP) 10.6 11.5 ADJUSTED AMP.= 33.6 > 14.4 PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, MAXIMUM INPUT VOLTAGE 48 V DC MAX. CURRENT(IMP X 1.25) 13.2 14.4 EGC MAX. CHANNEL ISC= 14.4 A DC EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 20 CONDUCTOR(THWN-2, (90°C))= 10 AWG EQUIPMENT,WITHOUT THE MAXIMUM USABLE DC INPUT POWER 330 W MAX. COMB.ARRAY AC CURRENT(IMP) 22.1 EGC CONDUCTOR RATING= 60 A WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. MAXIMUM OUTPUT CURRENT 0.96 A AC MAX.ARRAY AC POWER 5520W AC CONDUIT FILL DERATE= 1 AC OVERCURRENT PROTECTION 20 A AMB.TEMP. AMP. CORRECTION= 0.96 W W 0 a gMAXIMUM OUTPUT POWER 240 W AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) ADJUSTED AMP.= 57.6 > 14.4 Z 1_ 0 CEC WEIGHTED EFFICIENCY 97 % NOMINAL OPERATING AC VOLTAGE 240 V AC COMBINER BOX TO INVERTER RATED AMPS= 22.1 A AC z D 03 Q -I N.: NOMI NAL OPERATING AC FREQUENCY 47-68 HZ AC MAIN PV OCPD MAX.CURRENT(RATED AMPS X1.25)= 27.6 A AC Q 0 1- Q: LU C gi - Lo I- . o PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) MAXIMUM AC POWER 240 VA AC CONDUCTOR(THWN-2,(75°C))= 10 AWG 1- Z 1 cv)AC OUTPUT CURRENT 22.1 A AC MAXIMUM AC CURRENT 11.5 A AC CONDUCTOR RATING= 35 A W .. O m NOMINAL AC VOLTAGE 240 VAC MAXIMUM OCPD RATING PER CIRCUIT 20 A AC CONDUIT FILL DERATE= 1 - (f) AMB.TEMP.AMP.CORRECTION = 0.96 O Ct ADJUSTED AMP.= 33.6 > 27.6 EL a) > .` a U) 'CO (- GROUNDING NOTES STRANDED,AND BARE WHEN EXPOSED. USED TO PROTECT WIRE FROM SHARP EDGES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 Z t6 [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED.PER NEC, 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG INSULATED,90°C RATED,WET AND UV RESISTANT, RATED FOR 600V L_ CO [ii GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER Q i- CNJ N BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, 11.GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLOR VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. U) OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION I: O 2 GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS Q Q -• 0 LLI 0 CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10.NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS LL Q O 0 F- a 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66], DC FOLLOWS:DC POSITIVE-RED(OR MARKED RED), DC NEGATIVE-GREY(OR MARKED Z ca U) ›- NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#8AWG WHEN GREY) LU .L a U) ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: rd 1-r) 2 0 CD 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 14. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, DC POSITIVE-GREY(OR MARKED GREY), DC NEGATIVE-BLACK(OR MARKED BLACK) CD D_ - I- 0 o 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN 12.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: DRAWING BY 690.46]. ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. PHASE A OR L1-BLACK,PHASE B OR L2-RED,PHASE C OR L3-BLUE, NEUTRAL- Eric Thomas 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC WHITE/GRAY 690.42]. WIRING&CONDUIT NOTES *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND BE USED INSIDE DATE THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR APPROVED FOR THE SITE APPLICATIONS **USE-2 IS AVAILABLE AS UV WHITE June 8, 2018 TO ANOTHER MODULE. 2.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT; ROUTED TO BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC PROJECT NUMBER IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 51903766 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 14.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 690.8] FOR MULTIPLE CONDUCTORS COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC SHEET NAME GROUNDING LUGS. 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE 330.30(B). ELEC. CALCS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND DERATED ACCORDING TO[NEC TABLE 310.15(B)(2)(a),NEC TABLE 310.15(B)(3)(a), GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT &NEC 310.15(B)(3)(c)] PAGE NUMBER REVISION BURIAL. 5. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV PV6 O 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE V CAUTION BLU E RAVEN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED 1220 S.630E STE.430 SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: AMERICAN FORK,UT 84003 800-377-4480 W W W.BLU ERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF MAIN DISTRIBUTION ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT UTILITY DISCONNECT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, du EXCEPT IN CONNEC TION WITH THE ©GGGGGG©GCCQ SALE USE THE RESPECTIVE EQUIPMENT, WITHOUT THE CICICICIC 11:10 WRITTEN PERMISSION OF DDDRW RAPID SHUTDOWN AC RITTENVERMIS PERMISSION DISCONNECT SWITCH >- o w ® z o < Jti PV ARRAY < 0oLr i- FRONT OF HOME WU co 0 0 a) 11535 Southwest Terrace Trails Drive, Tigard, Oregon 97223 0 cn E LLL OU DIRECTORYRI PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF _ ti N THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC 2 a) ai c SYSTEM DISCONNECTING. 2 0 � w WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH o in o a OTHER, A DIRECTORY I SHALL BE INSTALLED AT EACH DC PV as SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING � Lo a o MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DRAWING BY DISCONNECTING MEANS IN THE BUILDING. Eric Thomas ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC ENGRAVE DATE IN CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE June 8, 2018 ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO PROJECT NUMBER SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE 51903766 WILL BE INSTALLED AS REQUIRED BY THE NEC. [NEC 690.56(B)&(C)] [NEC 705.10]. SHEET NAME PLACARD PAGE NUMBER REVISION PV10 0 '%%le#* Cut Sheet Cut Sheet BLUE RAVEN IRONRIDGE FlashFoot2 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 2) Assy, Hashing 800-377-4480 W W W.BLUERAVENSOLAR.COM ji ." "+ 9.0 ` CONFIDENTIAL-THE INFORMATION tik HEREIN CONTAINED SHALL NOT BE (---- j USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ICI ..... ,..__. PART TO OTHERS OUTSIDE i 2 - RECIPIENTS ORGANIZATION, 1.0 EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE 24 EQUIPMENT,WITHOUT THE �� WRITTEN PERMISSION OF i----'% BLUERAVENSOLAR LLC. � T . 12.0 j } o � Qa�o 111 --- 4: ,,411:), T O Z r Q J � �} Z d, Q ° N �.�-�/� + 0 Property Value Ur v Material Aluminum F- H W c pc O Finish Mill/Black U O C') O Q Co � � i Luo or 07 w Ct ITEM NO. DESCRIPTION Qty in Kit J a CO 1 BOLT LAGS 16 X 4.75" 4 I 2 ASSY, FLASHING 4 3 ASSY, CAP 4 I 4 WASHER,EPDM BACKED 4 3) Assy, Cap 4) Washer, EPDM Backed FLASHFOOT 2 40- "-I -..g— r .36 Part Number Description 0.35f14 FM-FF2-001 Kit,4pcs,FlashFoot2 (Mill) 1.56 FM-FF2-001-B Kit,4pcs,FlashFoot2(Black) I A_____i_3.301) Bolt, Lag 5/16 x 4.75 w 0.75 .26 5/16THD 0.63 (�.'} fl I 111111111111111111111111►. 7/16" ����1111!!!! Property Value Property Value Head "'I 4.75 ► Material Aluminum Material 300 Series Stainless Steel Finish Mill/Black Finish Clear Property Value Material 300 Series Stainless Steel Finish Clear v1.10 v1.10 SHEET NAME n,,....-ma, a :,,. a.«.m,x:s.:,..:... ........___as..: .:xmr..tt•::::::.:. ......... ..a....aa::.xe:•rsfr:::•:;::r#».: t.S:tae,, x••r .:•L'a" :3' .:Yx'"• ".Y.. '.N' :39.. x- .............. .. ...»., «»...r,..,t: a,. ...a:s•E... d9 aa,z 'rtE#;5:, x.,, t. .... x'Y„r ::G:;...: ,.,... I.x t.-r........,.«,,....«:kE.. .. , .sm.»...., x„. x. :xr,r^..�r..:s:•»...:�rz. z��:,Et:s�g{za:.;;.;gau;.;, «. ! , «.,«.....,.r.,.., ... . r � :.. .»•• .sat;.» ":.a-»_—... x•-#.,}rrs ..t« 'F.• ..::r..,«..a.»....t ,..» s. 3'..1.„ n' .,..,. .»»,« ,s[xsr.. .}. .»,.s., .. r :"' :?:f.,�'va:n".i:;,rs:5.. , ..:::,rr.-xa«.:ta. ..r,x.z... ::••:x x :�f„«.»...»a».,r &s .,.»,#,H »..,, 'L.,... . .S �t `33 <. . Y. ..a... ..h.at»,,,.,_.s.. z} ,.. 3. ::::;e3, . .:#�;. y:::?m:•>.rEg•.; .,, .x ♦,C 3y a�, '*Y . .«.. t _ ,x ., .. ..«.t en. ........ 3 sr ..»»..s..... a..£”. ,,. aiaf:._e., z.», z. r». ^x^ :.t s fl...:t..,...n .,9..,....,r•s.as. .»•�.,c t. .s"saS"'sr°!h,. :? x •r'.. a,......{,a. y # x�, f.,.srM z# �x..xE a•.... : .». .[;#;•z ,.. ^•, _ � s .. � �x x...r... .. «.......,..,. #} nx'x, ik,». :a.€h.«..sr.�£. _.,,.,«.:s .. x .. ti' 3x' ..,..» ..._x,rr..ss,.. ,x � .. : xi& ,. ..�s,.s r,'�f.,r m^•..2:.. .1... .r.rt' , s . r...� s�.»'k�'..,.�.s, x sr .Cir,..r.i' , . .z, __._x. •.,.<.,.r s.,, r _ «a.«...... ,• r. _.. .sx •b. ., x a.. t« ..:.. .xx ..�:3#S. rs l�.�Ws..._a.. .. s. , r�: z� ..... s. v{f 4 sa, .:s, ....« sx,.....,.. s.as t. ,y.•. # .. •Y r,. »,» ., �„ a. ... a. x A.....tx..@a.............a.,..»..,a..»a.. ._..�_.......Y....... ,r ......... . ........«,,.,,. ....W.s.. ,,ar....r3:3'EV .z$_.,. ..r. .r......s..,..,..,.s.... x. xzr` .. ". ... x a.{: « ... 5 , ,«. #.... d,xx... vr.,.,E....«x. .....« x r..3.,r.# .xt:,, r,,.xc ,,. ,. ».._»x�..s....rd;.,.:{x•...z.x,.}x3 a , , .,»,.r.,. ..«•,.r « s ab 1 . ,_yE� ... •E a.,., � ., ,.., .,.,.3 �'. ix• "f t,. .. .. 4. '54.. : E....., ,. ,.ra,E: ,. ..a..,.a.,,,...,.._..,..... z«,. .,... .,ux. s t. �a ;i is {a �:�°I.•x_ f.... x... ..........Em ». E;,.x , d t Y� YC ...,ax_.r.:r.. ._, , . a,, ,.. x. .. .m,rc-K .o: ,,�x.''�§'r.........a� .3 •x:::E:, ra,I...:a..x::F..,z,,:m E r x S •Fr , EE T4S.. . .s..«,.ar .. .... , « •r sxs.. ..,.,x. « xa x_ r..sr , xc «s .... i s r aaF „ x�= rx.t,€ ;a' s ...._...13. ., I��;�x�a�:..^. T xrx._�§ .� ..{...� r.s~(�•�}.t a ,� �� .,�tE,.E,��... � ,�.,. �. fi.� .x.,x�,t,,..0«x� �,� #s.,,�.r _i;,,#.�7�, „ � �,�„�:t�� �...,�s...�,�.��a.,�„a,�_~x.,,.. ..._��.. }' �;€�_.s�.za>: s,...,;.a xl€«..r•�...,..�x;x::,:r. Et J S."�'n"i n„�,rw ..-.-. ,.,,.u+,u§.•x si?,a'��„ ,.. _t„ « ,-, ,«..s x'sxi#xE.-r. .din^-. a-<ir�.,?rF_ .,t.r�.=•,a,�.�3°'.C.w.....C•`_f �z:r?ia�:..�xxxm :-'r�{;rn:r�`e•xxerx.•.t_:E{±?x... PAGE NUMBER REVISION DS 0