Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (61)
CITY OF TIGARD PLUMBING PERMIT '` Permit#: PLM2018-00227 ■ ' ' COMMUNITY DEVELOPMENT 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/01/2018 T i 1<'.I� g Parcel: 1 S135BA00100 Jurisdiction: Tigard Site address: 10125 SW WASHINGTON SQUARE RD Project: Jaguar/Land Rover Subdivision: None Lot: None Project Description: Site utilities for a new car dealership building and service facility. Contractor: VARIN CONSTRUCTION INC Owner: PPR SQUARE TOO LLC PO BOX 1623 PO BOX 847 SHERWOOD, OR 97140 CARLSBAD, CA 92018 PHONE: 503-570-1192 PHONE. FAX: FEES Quantity Description Date Amount 12 ea Catch Basin or Area Drain 08/01/2018 $225.12 Specifics: 737 If Footing Drain 08/01/2018 $312.67 10 ea Manholes 08/01/2018 $187.60 Type of Use: COM 24 ea Rain Drain Connector 08/01/2018 $450.24 Class of Work: NEW 1134 If Sanitary Sewer 08/01/2018 $475.26 Type of Const: 3419 If Storm Sewer 08/01/2018 $1,338.22 Occupancy Grp: 700 If Water Service 08/01/2018 $287.66 Stories: 1 ea Backflow Preventer 08/01/2018 $31.27 2 ea Backwater Valve 08/01/2018 $25.02 50 Misc Other Fee 08/01/2018 $50.04 1 Plan Review 08/01/2018 $845.78 1 12%State Surcharge- 08/01/2018 $405.97 Plumbing Total $4,634.85 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-00 it 0r•0. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: / ��v"r Permittee Signature: _ Call 503.639.4175 by 7:00 a.m.for the next available inspe c tion da f l. This permit card shall be kept in a conspicuous place on the job site unti comple ion of the project. Approved plans are required on the job site at the time of eac in .ection. . Plumbing Permit Application S/9,/,/,. -' Site Utilities FOR OFFICE USE ONLY City11 of Tigard • _�y "�J g L�° a?7-7 PermitNo.:/ lr 0))2 f 13125 SW Hall Blvd.,Tigard,OR 97223 RECEIVEDew,f 'r' /J Phone: 503.718.2439 Fax: 503.598.1960 Date/By: .o- ig Other Permit No.: TI G A R D Inspection Line: 503.639.4175 Date Ready/By 2„(/�-duns H See Page 2 for Internet: www.tigard-or.gov p f y 9 2. 1IITotified/Metho i�0 Y'r -'�(� Supplemental Information TYPE OF WORK gg IWt U r l FkF �/ e FEE* SCHEDULE ®New construction 0 Demoli A fY Ortrg'IGARD For special information use checklist. _ p 0 Othe UILDI G DIVISION New 1-ton I Qty. Ea. Total ❑Addition/alteration/replacementNew 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 0 1-and 2-family dwelling Z Commercial/industrial SFR(2)bath 437.78 ❑Accessory building 0 Multi-family SFR(3)bath 500.32 Each additional bath/kitchen 25.02 ❑Master builder 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION` Site utilities: Job site address: 10125 SW Washington Square Road Catch basin or area drain %',1 18.76 aa 5: f Drywell,leach line,or trench drain 18.76 City/State/ZIP:Tigard Footing drain(no.linear ft.:(73r[ ✓r t'` Page 2 312.67 Suite/bldg./apt.no.: I Project name:Jaguar Land Rover Manufactured home utilities 50.03 Cross street/directions to job site:West of Greenburg,north of Highway 217 Manholes ✓' Q 18.76 f g, ‘© J ,)),,fq /.yam Tr ely0 A ±� I C cP [i) Rain drain connector °r ` 9?{ 18.76 4SG,, 4E tIIa ii /j� � Sanitary sewer(no.linear ft.1/? V p'). Page 2 4 5 6 �C+ T .ire C . r _ r �irr'dj Storm sewer(no.linear ft.'�¢Iq t✓° 3 5 Page 2 /.14-36;,14 ,�/,,, Water service(no.linear ft.:7� q Page 2 287.66 Subdivision: r 4e4 s---/q/f 6'y ,ot no.:100 Fixture or item: Tax map/parcel no.:1S1 35 BA Backflow preventer Y'' 1 31.27 31.27 DESCRIPTION OF WORK Backwater valve If2 12.51 25.02 Clothes washer 25.02 Site utility construction. Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 PROPERTY OWNER I 0 TENANT Expansion tank 12.51 Name:PPR Square Too,LLC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address: 11411 N Tatum Blvd Garbage disposal 25.02 City/State/ZIP:Phoenix,AZ 85028 Hose bib 25.02 Phone:(503)639-8865 Fax:( ) Ice maker 12.51 ® APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02 Business name:Mildren Design Group Medical gas(value:$ ) Page 2 Primer 12.51 Contact name:Curt Trolan Roof drain(commercial) 12.51 Address:7650 SV<Beveland St,Ste 120 Sink/basin/lavatory 25.02 City/State/ZIP:Tigard,Oregon 97223 Solar units(potable water) 62.54 Phone:(503)244-0552 Fax::( ) Tub/shower/shower pan 12.51 E-mail:curt@mdgpc.com Urinal 25.02 Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:Varin Construction WaterPip g/1 m DWV 56.29 Address:PO Box 1623 Other: S±e-m F (by iJauji=t „/; 25.02 50,04 City/State/ZIP:Sherwood,Oregon 97140 car +cZtkt -S_t(.)coo. '.v ( Subtotal 3„it Phone:(503)570-1192 Fax:(503)682-3928 Minimum permit fee: $72.50 -- permit ?'Its",. '18' .7 CCB Lic.:63065 Yi/"2 � Plumbing Lic.no.: Plan review (25%of fee) - Authorized signature: State surcharge(12%of permit fee) 4o5.'/'7 ,/ 1�� TOTAL PERMIT FEE 44 34-est Print name:Curt Trolan Date:5/9/2018 This permit application expires if a permit is not obtained within)80 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\PLMU-PermitApp.doc 10/01/09 440-4616T(10/02/COM/WEB) A Plumbing Permit Application - City of Tigard Page 2 - Supplemental Information Fee Schedule: Residential Fire Suppression Systems: Site Utilities Qty. Fee(ea) Total Square Footage: Permit Fee: Footing drain-1C 100' 1 50.03 50.03 0 to 2,000 $121.90 Footing drain-each additional 100' 7 37.52 262.64 2,001 to 3,600 $169.69 3,601 to 7,200 $233.20 Sewer-1st 100' 1 62.54 62.54 7,201 and greater $327.54 Sewer-each additional 100' it 37.52 Ota.ria Water Service-1st 100' 1 62.54 62.54 Medical Gas Systems: Water Service-each additional 100' 6 37.52 225.12 Valuation: Permit Fee: Storm&Rain Drain-1st 100' 1 62.54 62.54 $1.00 to$5,000.00 Minimum fee$72.50 Storm&Rain Drain-each additional 100' ,�4 37.52 rj $5,001.00 to$10,000.00 $72.50 for the first$5,000.00 and$1.52 for Other Inspections or Fees Qty. Fee(ea) Total each additional$100.00 or fraction thereof,to and including$10,000.00. Inspection of existing plumbing or for $10,001.00 to$25,000.00 $148.50 for the first$10,000.00 and$1.54 for which no fee is specifically indicated 90.00/hr each additional$100.00 or fraction thereof,to (minimum charge-1/2 hour) and including$25,000.00. Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379.50 for the first$25,000.00 and$1.45 for hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to Reinspection Fees 90.00/hr and including$50,000.00. Additional plan review for revisions 90.00/hr $50,001.00 and up $742.00 for the first$50,000.00 and$1.20 for (minimum charge-1/2 hour) each additional$100.00 or fraction thereof. Subtotal: y�4i3 c! Other Fixtures: Commercial Fixture Work: Are you capping,adding or replacing fixtures? If"yes", please indicate work performed by fixture. Failure to accurately report fixtures could result in increased sewer fees*. Quantiy by Fixture Type Fixture Type for Replace/ Plan Review for PlumbingInstallations Work Performed: Capped Added Relocate Baptistry/Font Plan review is required for any of the following. Bath -Tub/Shower Please check all that apply. -Jacuzzi/Whirlpool 1:1Any new commercial building with water service 2"and Car Wash -Each Stall greater,except systems designed and stamped by licensed -Drive Thru engineer. Cuspidor/Water Aspirator ❑ New exterior plumbing site utilities for any complex structure Dishwasher -Commercial as defined in OAR918-780-0040. -Domestic 0 Medical gas and vacuum systems for health care facilities. Drinking Fountain ❑ Any multipurpose fire sprinkler system. Eye Wash 0 Any complex structure as defined in OAR918-780-0040. Floor Drain/sink -2" 3" Submit 2 sets of plans with any of the above. -4" Car Wash Drain Isometric or Riser Diagram Garbage -Domestic-non-food g Disposal -Domestic-food related 0 Isometric or riser diagram is required for new buildings -Commercial-food related that meet the qualifications above. -Industrial-food related Ice Mach./Refrig.Drains Oil Separator(Gas Station) Rec.Vehicle Dump Station Comments regarding fixture work: Shower -Gang -Stall Sink/Lav -Non-food related -Bradley -Commercial-food related -Service Swimming Pool Filter Washer-Clothes Water Extractor *Note: If the fixture work under this permit results in an Water Closet-Toilet increase of sewer EDUs,a sewer permit will be issued and Urinal fees assessed for the sewer increase must be paid before the P:\116139 Land Rover-Jaguar Washington Square\consultants\TM Rippe Civil\20180425 Permit Applications\2018-4-18 Plumbing Permit Application Partially Complete.doc plumbing permit can be issued. I:\Building\Permits\PLMF-PermitApp.doc 12/30/05 Site Utilities — Plumbing Permit Application Plan Submittal Requirements TIGARD A plumbing permit for site utility plumbing work is required for sanitary sewer, storm sewer and potable water systems on private property. 1. SITE PLAN and vicinity map showing the geographic location (fully dimensional, drawn to scale) labeled with: A. ® map &tax lot# ® project name ® site address ® suite number ® zoning ® applicant name ® phone number B. North arrow. C. Scale (architectural or engineering only). D. Street names. E. Building pads with project location. 2. PLUMBING PLANS -Two (2) complete sets, civil only. All details listed below shall be incorporated into the plumbing plans: A. Storm drainage plan showing: 1) Finish elevations throughout the developed site. 2) Grade breaks determining area serving each catch basin. 3) Location of catch basins. 4) Pipe size. 5) Type of material. 6) Slope of piping. 7) Manholes and field drains. 8) Cleanouts provided for each 100 feet or fraction thereof. 9) Roof drain laterals specifying cleanouts at each upper terminal. 10) Location of existing or proposed connection to a public sewer line. B. Utilities plan showing: 1) Sanitary sewer line location,pipe size, type of material, slope of piping, manholes and cleanouts provided as required for storm. 2) Size and location of domestic water piping and drainage. 3) Proposed location of connection to a public water or sanitary sewer line. I:\Building\Permits\PLMF-PermitApp.doc 12/30/05 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT II r Transmittal Letter etter T 1 G A R D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: ' Q`C1 DATE RECEIVED• DEPT: BUILDING DIVISION REC. E 1 ED FROM: NO 19 2018 1R X. C-5\U.K. - OF TIGARD COMPANY: -C-N ,? :UILDING fl3 i A! PHONE: r-"� .- 3• -� By:' yr" (4_7)904--- CX)o 7 RE: Od\ 5 S"" V JC,k, c AUl - (Site Address) (Permit Number) (Project name or subdivision name and lot number /\Z°t 1(Pic t ' r ATTACHED ARE THE FOLLOWING ITL !,•: Copies: Description: ,i Copies: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. $ i Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations iblfrit Engineer's calculations. Other(explain): I. REMARKS: e..l�Sx_c \ k_c.c4 ` �\CA�RS FOR OFFICE USE ONLY Routed to Permit echnician: Date: //-, 6-2ct e-, Initials: 4 Fees Due: X es ❑No Fee Description: Amount Due: ! o $ $ $ Spe al I ! ructions: eprint Permit(per PE): ❑ Yes ❑ No E Done Applicant Notified: J Date: ///;1/1 y Initials: &"— I:\Building\Forms\TransmittalLetter-Revisions 061316.doc 11\Z- TM RIPPEY K. CONSULTING ENGINEERS7650 SW Beveland Street,Suite 100 Tigard,Oregon 97223 1 �, CONSULTING Phone: 503 443 3900 astout@tmrippey.com LETTER OF TRANSMITTAL November 19, 2018 N O V 1 9 2018 C TY 1:.;= 110-ARD BUILDING DOViSiON Project Number: 17260 Don Sylvesterd Plumbing Division City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Jaguar Land Rover Dealership Enclosed: • For your review,three copies of sheets CO and C3.3, showing revisions to the General Utility notes and the sanitary sewer system, under Revision 10 (RFI 59 & 61). Please review and respond to Karl Koroch in the TMR office. Alex Stout cc: Karl Koroch(TMR) Delivered p:\2017 projects\17260 mdg land rover washington square\sewer\2018-11-19--ss review transmittal.doc