Loading...
Report (127) PLAN 2885r kr)k. �1 0-)5 T t D t'1 U'� 1.5()V BeamChek v2016 licensed to: Z26 .Q . GRAND FIREPLACE HEADER -$K'i14N AT PAINT L 0a Date:3/02/18 Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=14.4 in2 R2=7.3 in2 (1.5)DL Defl= 0.02 in Recom Camber=0.03 in Data Beam Span 3.5 ft Reaction 1 LL 413# Reaction 2 LL 744# Beam Wt per ft 14.94# Reaction 1 TL 9330# Reaction 2 TL 4773# Bm Wt Included 52# Maximum V 9330# Max Moment 9303'# Max V(Reduced) 9315# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max Defl L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(in') TL Defl(in) IL Defl Actual 123.00 61.50 0.02 <0.01 Critical 46.52 58.22 0.18 0.12 Status OK OK OK OK Ratio 38% 95% 11% 1% Fb(psi) Fv(psi) E(psi x mil) Ed (psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00. Le=0.00 Ft Loads Point TL Distance Par Unif LL Par Unif TL Start End B=12000 1.0 463 H=820 1.0 3.5 J H Pt loads E I R1 =9330 R2=4773 SPAN=3.5 FT Uniform and partial uniform loads are lbs per lineal ft. PLAN 2885 BeamChek v2016 licensed GRAND FIREPLACE HEADER — 5e'G-rron/41' PI11Eft1q Date:3/02/18 Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=0.7 in2 R2=0.7 in2 (1.5)DL Defl= <0.01 inRecom Camber=<0.01 in. Data Beam Span 5.0 ft Beam Wt per ft 14.94# Reaction 1 TL 487# Reaction 2 TL 487# Bm Wt Included 75# Maximum V 487# Max Moment 609 It Max V(Reduced) 292# TL Max Defl L/240 TL Actual Defl L/>1000 Attributes Section(in3) Shear(in2) TL Defl(in) Actual 123.00 61.50 0.00 Critical 3.05 1.83 0.25 Status OK OK OK Ratio 2% 3% 1% Fb(psi) Fv(psi) E(psi x mil) Fc.(psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft toads Uniform TL: 180 =A Uniform Load A R1 =487 R2=487 SPAN=5 FT Uniform and partial uniform loads are lbs per lineal ft. PLAN 2885 BeamChek v2016 licensed to: GRAND FP CRAWLSPACE Date:3/02/18 Selection (3)2x 10 DF-L#2 Lu=0.0 Ft Conditions NDS 2015 Min Bearing Area R1=2.2 in2 R2=2.2 in2 (1.5)DL Defl= 0.07 in Data Beam Span 11.5 ft Reaction 1 LL 1035# Reaction 2 LL 1035# Beam Wt per ft 10.11 # Reaction 1 TL 1352# Reaction 2 TL 1352# Bm Wt Included 116# Maximum V 1352# Max Moment 3887'# Max V(Reduced) 1171 # TL Max Defl L/240 TL Actual Defl L 1635 LL Max Defl L/360 LL Actual Defl L/927 Attributes Section(ins) Shear(in2) TL Defl(in) LL Defl Actual 64.17 41.63 0.22 0.15 Critical 47.11 9.76 0.58 0.38 Status OK OK OK OK Ratio 73% 23% 38% 39% Fb(psi) Fv(psi) E(psi x mil) Fc_l_(psi) Values Reference Values 900 180 1.6 625 Adjusted Values 990 180 1.6 625 Adjustments CF Size Factor 1.100 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL: 180 Uniform TL: 225 =A • Uniform Load A R1 =1352 R2=1352 SPAN= 11.5 FT Uniform and partial uniform loads are lbs per lineal ft.