Permit (56) CITY OF TIGARD MECHANICAL PERMIT 111-..- COMMUNITY DEVELOPMENT Permit#: MEC2018-00455 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/01/2018 t�`'`+Iz_« g Parcel: 2S101AC90022 Jurisdiction: Tigard Site address: 7125 SW HAMPTON ST Project: Special Districts Association of Oregon Subdivision:-IAMPTON STREET BUILDING CONDC Lot: 2 Project Description: Mechanical upgrades to building:Removing(11)split system heat pumps and fan coils and replacing with(1)VRV Heat Recovery System.Installing(17)indoor fan coils above t-bar ceiling on first and second floors. Contractor: CJ HANSEN CO INC Owner: SPECIAL DISTRICTS INSURANCE SVCS PO BOX 7397 PO BOX 12613 SALEM, OR 97303 SALEM, OR 97309 PHONE: 503-362-3643 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 07/24/2018 $9,584.59 Class of Work: ALT Type of Const: VB Plan Review 07/24/2018 $2,396.15 Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 07/24/2018 $1,150.15 Stories: 2 Misc Administration Fee 07/24/2018 $13.50 Info Process/Archiving-Lg$2.00(over 07/24/2018 $34.00 Project Valuation: $338,861.00 11x17) Info Process/Archiving-Sm$0.50(up to 07/24/2018 $27.50 Fuel Air Handlers 11x17) Fuel Types: Electricity Units<10000 cfm: Gas Pressure: Units>10000 cfm: 17 Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $13,205.89 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: 1 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to O'UNCC)by calling/ 503.232.1987 or 1.800.332.2344. Issued By: rte Permittee Signature: i�------ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application [OR 01 i icF I SE oyL1 Received City of Tigard �!,ry,w / 3 Permit Nn.: � 13125 SW Hall Blvd.,Tigard,OR 97223Rh t,te/B RvteV / O /� ��>yS�— _ Phone: 503.718.2439 Fax: 503.598.1960 -Date/By: 7' ) j Other Permit: T 1 G A K U Inspection Line: 503.639.4175 Date ReadyBj y: Juris: See Page 2 for Internet: www.tigard-or.gov JUN 1! 2018 Notified/Method:7 r /, -pr, Supplemental Information �..TYPE OF WO'+ -., r; 'r C1 I�tMI:f(C1AL IrEV.SCiailULll:- `' E' :CI .. Mechanical permit fees*are based on the value of the work ❑New construction ►/ Addition/alters ip lti)IVISION performed.Indicate the value(rounded to the nearest dollar)of all O Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$338,861 CATEGORY Ul# CONSTRI ICTIUN RESIDENTIAL"EQUWMENT/SYST IS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial 0 Accessory building For special information use checklist. O Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address:7125 SW Hampton Street Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Portland,Oregon 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Project name:SDAO Mechanical Upgrades Heat pump 61.06 Suite/bldg./apt.no.: Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision: 1 Lot no.: Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DECRIl'II©N OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas Mechanical and Electrical Upgrades to the existing building. fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 tI PROPERTY OWis1ER ►® TENANT Environmental exhaust and ventilation: Name:Special Districts Association of Oregon Range hood/other kitchen equipment 33.39 Address:7125 SW Hampton St#200 Clothes dryer exhaust 33.39 Portland,OR 97228 Single-duct exhaust(bathrooms, City/State/ZIP: toilet compartments,utility rooms) 23.32 Phone:(503)443-2372 Fax:( ) Attic/crawlspace fans 23.32 ii APPLICANT CONTACT PERSON Other: 23.32 Fuel piping: Business name:C.J.Hansen Co.,Inc $14.15 for first four;$4.03 for each additional Contact name:Chad Roofener Furnace,etc. - Gas heat pump Address:3552 Silverton Road NE Wall/suspended/unit heater City/State/ZIP:Salem,Oregon 97305 Water heater Fireplace Phone:(503)362-3643 Fax::(503)566-3487 Range E-mail:estimate@cjhansen.com Barbecue CONTRAC f OR Clothes dryer(gas) Other: Business name:C.J.Hansen Co.,Inc MECHANICALPERMIT FEES* Address:3552 Silverton Road NE Subtotal Minimum permit fee($90.00) City/State/ZIP:Salem,Oregon 97305 Plan review(25%of permit fee) Phone:(503)362-3643 Fax:(503)566-3487 State surcharge(12%of permit fee) CCB lie.:499 / (F262-1) TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-County Building Industry Service Board Print name:Chad Roofener Date:6/6/18 1:\Building\Permits\MEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB) Mechanical Permit Application - City of Tigard ' Page`2 - Supplemental Information Commercial& Multi-Family Fee Schedule: Total Valuation: Permit Fee: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 Branden Taggart From: Chad Roofener <Estimate@cjhansen.com> Sent: Monday, June 11, 2018 12:54 PM To: Branden Taggart Cc: Chad Roofener Subject: 7125 SW Hampton Street - SDAO Mechanical Upgrade Attachments: TM Rippey.pdf;22 30 00 Plumbing Fixtures.pdf Importance: High Branden, First off,thanks for allowing this supplement information to be sent via email. Attached is some additional information on the engineering that was completed by TM Rippey for the new equipment that may be helpful. Project Description: The project consist of removing the existing eleven (11) split system heat pumps and fan coils that currently serve this two story building and replace with one (1)VRV Heat Recovery system. The existing 11 heat pump units are currently installed on the roof with the fan coils being installed above the t- bar ceiling or below in the crawl space. The existing roof curbs that the heat pumps sit on will be removed by us and re-roofed by others under a separate contract. The new VRV outdoor unit will be a heat pump type with variable refrigerant flow zoning fan coil system capable of simultaneous cooling and heating as needed for each zone. The one (1) outdoor VRV heat pump unit will be located on the roof and mounted on a roof curb. The seventeen (17) indoor fan coils will be installed above the existing t-bar ceiling on the first and second floors and one within the crawl space. Outside air and heat recovery process will be provided by two (2) roof top heat recovery units mounted on a roof curb and ducted accordingly. There is going to be one standalone ductless split system to serve the existing electrical room. The VRV heat pump and fan coil unit information is in the packet with a cover page titled Section 23 78 00 VRV Equipment. The heat recovery unit information was in the packet with the cover page titled Section 23 74 00 Central Station HVAC Unit. The standalone ductless system information is in packet with a cover page titled Section 23 80 00 Terminal HVAC Equipment. These titles reflect the Engineers specification sections. All of this unit information was included with the plans delivered this morning. There is one (1) electric residential style 50 gallon water heater(see attached)that will get replaced and we figured this would fall under the state or Oregon minor label permit process. There is an electrical aspect to this project and Portland Electrical Construction Inc will be submitting for this permitted work. Scott Miller at MFIA Inc is the Engineer of record for this project. Let me know if there is any additional information needed for this and if necessary, we could schedule meeting to review this project in person at your office. Thanks again for your time and assistance with this project. Chad Roofener C..1.Hansen Co.,Inc. P. O. Box 7397 3552 Silverton RD NE Salem, OR 97303 (503) 362-3643/FAX (503) 566-3487 Cell (503) 932-2835 estimateCa�cjhansen.com 1 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7125 SW HAMPTON ST, TIGARD, OR, 97223 Record Type: Record ID: Commercial - Mechanical MEC2018-00455 Inspection Type: Inspector: 699 Mechanical final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor