Report (108) 4sc3
OFFICE COPY -\ ) .
C. J. Hansen Co., Inc.
*TRANE DEALER MECHANICAL CONTRACTORS SINCE 1948 *PLUMBING
*BOILERS P.O.BOX 7397 3552 SILVERTON RD NE *MECHANICAL PIPING
*HYDRONICS SALEM,OREGON 97303 *COMMERCIAL HVAC
*PRESSURE VESSEL *FIRE SPRINKLER
*ASME PHONE(503)362-3643,FAX(503)371-7627,EMAI *DESIGN/BUILD
*CLIMATE CONTROL r, *24/7 SERVICE
CCB 499
JUN 12 2018
CITY OF TIGARD
BUILDING DIVISION
Special Districts Association of Oregon
SDAO Office Mechanical/Electrical
Systems Upgrade
Submittals
Section 22 30 00 - Plumbing Equipment
Page 1
SMACNA National Safety Award Winner 1999, 2000(3rd place), 2001 &2011 (1st Place)
0 FERGUSON
ENTERPRISES,INC.
Page
WH-1 WATER HEATER 3
NOTE: OFFERED SUBJECT TO APPROVAL:
MODEL SPECIFIED IS DISCONTINUED
AENLB50202172000 AO SMITH 48G 4.5KW 240V 1PH LB WHTR ALUM (WITH 4
BLANKET)
HQS50 HUBBARD 75 WATER HEATER BODY STRAP 6
ET EXPANSION TANK 7
AST5 AMTROL 2 GAL TANK VOL THERM-X-TROL THERMAL 8
EXPANSION TANK NON-ASME
Page:2/9
0 FERGUSON
ENTERPRISES,INC.
WH-1 WH-1 WATER HEATER
NOTE: OFFERED SUBJECT TO APPROVAL: MODEL SPECIFIED IS
DISCONTINUED
AENLB50202172000 AO SMITH 48G 4.5KW 240V 1PH LB WHTR ALUM (WITH BLANKET)
HQS50 HUBBARD 75 WATER HEATER BODY STRAP
Page:3/9
WH-1 WATER HEATER
S°A SI"flith.the
Residential Electric
Water Heaters
nm
NiMA
mr err^'` '
a.
ENLB5O2O2172000
ENHANCED HEATING ELEMENTS CODE COMPLIANCE + Srnittt
• Dual 4500 watt elements for fast recovery • Meets UBC and ICC National Codes and
and reliable operation.* listed with CEC. i�, � � ���,
• Incoloy stainless steel lower element lasts • Complies with the Federal Energy
longer than a standard copper element. Conservation Standards effective s
April 16,2015,in accordance with the
e d F
DYNACLEAN'"DIFFUSER DIP TUBE Energy Policy and Conservation Act r �
• Helps reduce lime and sediment buildup (EPCA),as amended.
and maximizes hot water output.Made '
from long-lasting PEX cross-linked APPROVED FOR MANUFACTURED
polymer. HOUSING
HIGH ENERGY FACTORS • All residential electric water heaters are q
compliant with HUD Standards for mobile
• Eco-friendly non-CFC foam insulation, homes/manufactured housing.
heat traps and other features combine
CERTIFIED TO UL 174 FOR HOUSEHOLD
to yield a higher Energy Factor that
ELECTRIC WATER HEATERS
maximizes savings on operating costs. o
COREGARD'"ANODE ROD CSA CERTIFIED AND ASME RATED T&P rM
RELIEF VALVE
• Our anode rods have a stainless steel )
core that extends the life of the anode DESIGN-LISTED BY UNDERWRITERS
rod allowing superior tank protection far LABORATORIES
longer than standard anode rods.
• Certified at 300 psi test pressure and 150
BLUE DIAMOND°GLASS COATING psi working pressure.
• Provides superior corrosion resistance • Listed
veining stoaccordrage tankto UL 1type elect74 ricws
ater
compared to indust standard glass
lining. heaters.
ENHANCED-FLOW BRASS DRAIN VALVE
6-YEAR LIMITED TANK AND PARTS
• Our residential water heaters have a solid WARRANTY
brass,tamper resistant,enhanced-flow,
• For complete information,consult written
ball type,drain valve.
warranty or go to hotwater.com.
• Uses a standard female hose fitting that �' F
allows for fast and easy draining during �' ��
maintenance.
• Designed for easy operation,this valve
includes an integral screwdriver slot that
features a Y�turn(open/close)radius,
which not only permits full straight-
through water flow but also a quick and G.
0,-t!itn1
positive shut off.
*Model ENL-20 has a single element,
e February 2016 A.0.Smith Corporation.All rights reserved. Page I of 2
www.hotwater.com 1800.527.1953 Toil-Free USA I A.0.Smith Corporation 1500 Tennessee Waltz Parkway I Ashland City,TN 37015 AOSRE50602
Page:4/9
WH-1 WATER HEATER
f S rnResidential Electric
® Water Heaters
4. 5 KW 240V 1 PH LB
'y lu iI First Hour Pi' ;Recovery Element Wattage,240V ;.DimensionsInInches
Mp el CallanRatEnergy 90 False Appro ,I'�r
„I Nutt et II,'i opacity : Callan bit
Factor Galion Per Standard Maximum A B C
1Nei1� sM1
„Hour.°-.— �-u_,�r r a ..�— mm _ 9�
Tall Model l'01���II ul �roa _.1' 41,1041 k100
ENT-30t 30 47 0.95 21 4500 6000 46-1/2 39-1/2 19 95
ENT-40t 40 51 0.95 21 4500 6000 60-1/4 53-1/4 20 118
ENTB-50* 50 70 0.95 21 4500 6000 60-1/4 51-1/4 21 131
ENT-50t 50 71 0.95 _ 21 _ 4500 6000 60-1/2 51-1/4 22 134
ENT-55t 55 76 0.94 21 4500 6000 56-1/2 48-1/2 24 145
ENSB-30* 30 48 0.95 21 4500 6000 39 _ 30-1/2 20 95
ENS-30t 30 49 0.95 21 4500 6000 39-3/4 _ 30-1/2 22 94
ENS-40t 40 55 0.95 21 4500 6000 50 40-3/4 20-1/2 109
ENS-50t 50 62 0.95 21 4500 6000 49-3/4 40-3/8 23 161
Lowboy �i i �� )I a d
ENL-20 19.5 N/A N/A 21 4500 6000 30 21-1/4 20 65
ENLB-30* 28 40 0.95 21 4500 6000 30 21-3/4 22 96
ENL-30t 28 43 0.95 21 4500 6000 31-1/4 _ 21-3/4 24 115
ENLB-40* 38 46 0.95 21 4500 6000 31-3/4 24 24 118
38 44 0.95 21 4500 6000 33-1/2 24 26 118
ENLB-435i0."J 48 57 0.95 21 4500 6000 34 25 26-1/2 172
Male 3/4°water connections on 8"center.
*Models ship with supplied insulation blanket.
tFor 10-year tank and 6-year parts warranty,change"E"to"P"in the model number(example:ENT-30 becomes PNT-30).
+Top T&P option not available on this model.
ENL-20 is a single element configuration only
Optional T&P location#2 is used on the ENT-50,ENTB50,ENT-55,ENS-40 and ENS-50
Top T&P is not available on the 10 year model PNLB-50.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
A
T&P VALVE ez
INSNIM
ACCESS ANODE (OR OPTIONAL
PANEL T&P LOCATION #1)
OPTIONAL T&P
LOCATION #2
B A C O o 0 JUNCTION
BOX
T&P VALVE
ACCESS
PANEL
DRAIN
VALVE C°
For technical information call 800-527-1953.A.0.Smith Corporation reserves the right to make product changes or improvements without prior notice.
®February 2016 A.0.Smith Corporation.All rights reserved. Page 2 of 2
www.hotwater.com I 800-527-1953 Toll-Free USA AOSRE50602
Page:5/9
WH-1 WATER HEATER
•
PRODUCT SPECIFICATION DRAWING
QUICK STRAP® #QS-50
Seismic support for water heaters
' 1le ' � e
e � e
e
Strap o
0
0 0
Iiiil
+ � 38
1 1/2" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
ALL DIMENSIONS IN INCHES
CIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
J-Clip Carriage Bolt,#3/8-16 x 3.0"long 3/8"Hex Nut
The QUICK STRAP® #QS-50 is a seismic/earthquake support system for
water heaters up to 80 U.S. gallons in size. The system includes: (4) Straps,
(2) J-Clips, (2) 3/8" Carriage Bolts and (2) 3/8" Hex Nuts. The Quick Link®
system allows for full adjustment from the front side of the water heater.
•teaCAUVOIRPIM WOOM tin
Product Information: U
ACCEPTABLE
METHOD
.2215
• Material: Strap, 24 gage CRS, galvanized No.07-010 0
• California Division State Architect (DSA) approval #97-010
Product Submittal
• UPC / IPC / IAPMO listed Job Name:
Date:
THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE Part Number: Qty:
WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT
WRITTEN AUTHORIZATION.
_ ® Architect/Amer:
HOLDDL JContractor:
Notes:
CONVERTING MAKESHIFT METHODS INTO ENGINEERED SOLUTIONSsM
800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM
spec_QS-50_Revl
Page:6/9
0 FERGUSON
ENTERPRISES,INC.
ET ET EXPANSION TANK
AST5 AMTROL 2 GAL TANK VOL THERM-X-TROL THERMAL EXPANSION TANK NON-
ASME
Page:7/9
• ET EXPANSION TANK
it ,!.!,-_ ,,,;,- ,,--,-,-.Y,.,.,:L1i,ki,,,,,-,:,'H- E',.,.,.,-,,,,,,,,,,,,,,,-,J,<!,,-,,,-,mt-; .-:....l .-. , -.:z„.,„p:;„,t,,,,i,g,,,.,r„,,-, s;t,ti-,...-,-l.„,o_--,-,:q,.,,a1lipa V PIr will
iii I�h�I i"� ._.;Ii IliW1l 191���4hll�i�� 0 )
A- --.,--,,''',,'!-':-,,-,;1,1-,,:,,-,,,,,' „,
lIi 411IpIki I � oil1„.11,11, ,r
a` �,l Thermal Expansion Tanks ST'S !ries Non-AS
....... glib �a4,. _:. "=�i���ai u �3dI- -� ' '"a�da�p�i�I�I, ,.- i.� »,. d5iil, �i ���t�” ua
. . �II..i .s...ti Inaa,. 'a '�.� .._, &au,r�
AMTROL. 150 PSIG Working Pressure
Construction Application
Shell Steel • For use in closed, potable water systems to control
Diaphragm Heavy Duty Butyl NSF/ANSI 61 pressure build-up.
Liner Antimicrobial •Accepts expanded water as system temperature
System Connection Stainless Steel rises and returns hot water to system when
Finish Urethane Topcoat demand occurs.
Water Circulator Turbulator' •Stand models designed for large residential and
Air Valve Projection Welded light commercial applications.
Factory Precharge In-line Models 50 PSIG(3.5 bar) ••Multiple units can be installed to accommodate
Stand Models 40 PSIG(2.8 bar) larger systems.
Performance
Maximum Operating Temperature 200°F(93°C)
Maximum Working Pressure 150 PSIG(10.3 bar)
Warranty 1 Year-ST-30V through ST-210V
5 Years-ST-5 through ST-25V
In-Line Models A
__
Tank Max A B System Shipping core eactmlon
Model Connection —
Volume Acceptance Tank Diameter Tank Height Weight —
Number Fac or (NPTM)
Gal Lit In mm In mm In Lbs Kg
B
1ST-5 2.0 8 .45 8 203 13 330 1/4 5 2
ST-8 3.2 12 .59 9 229 15 381 1/4 7 3
Charging1111111111r -
ST-12 4.4 17 .73 11 279 15 381 '/4 9 4 Vaive
Stand Models
Tank A B System Shipping A J
Model Volume Max. Tank Diameter Tank Height Connection Weight
14 H Charging
Number Acceptance (NPTF) g Valve
s.V
Factor —
Gal Lit In mm In mm In Lbs Kg
ST-25V 10.3 39 1.00 15 381 19 483 1/4 23 10
ST-30V 14.0 53 0.81 15 381 24 610 1/4 25 11
ST-42V 20.0 76 0.57 15 381 32 813 1/4 33 15
ST-60V 34.0 129 1.00 22 559 30 762 1% 61 28 B
ST-80V 44.0 167 0.77 22 559 36 914 1% 69 31
ST-180V 62.0 235 0.55 22 559 47 1194 11/4 92 42
ST-200V 81.0 307 0.44 22 559 56 1422 11/4 103 47al .m cony action
ST-210V 86.0 326 0.54 26 660 47 1194 11/4 123 56
All dimensions and weights are approximate.
Job Name Notes
g
® PEa
CERTIFIED TO �
Engineer NSF/ANSI 61
Contractor LOW-LEAD
IAPMUa
P.O.No.
MADE IN USA
Sales Rep.
A
Model No. ASk f:''' ,.-
ANTIMICROBIAL ` 4-'
rROTECiiotC RBULA°
MC 4400(01/17) Amtrol Inc.,1400 Division Road,West Warwick,RI 02893 USA T:401.884.6300 www.amtrol.com 39
Page:8/9
FERGusoN
"AS IS" Disclaimers
The information contained in this submittal is a compilation of product information made
available by manufactures or other suppliers about their products, and while Ferguson
Enterprises, INC. ("Ferguson") makes reasonable efforts to present current information in
the form in which it is received by Ferguson, the information is provided to you "AS IS,"
for your internal informational purposes only, without any representation or warranty of
accuracy or completeness of information or other warranty of any kind, including any
implied warranty of quality, merchantability, fitness for a particular purpose, or non-
infringement. In no event will Ferguson be liable to any party for any direct, indirect,
incidental, special or consequential damages for use of or reliance upon any information
or material presented including, but not limited to, damages arising from loss of profits,
business interruption or any other damages, even if Ferguson is expressly advised about
the possibility of such damages, to the fullest extent allowable by law. The material in
this submittal could contain technical inaccuracies or typographical errors, and
information will be changed, updated and deleted without notice. Manufacturers or
other suppliers may make improvements and/or changes in the products described in this
material at any time.
Customer Service Policy
Ferguson enterprises, Inc. is unconditionally committed to customer service satisfaction.
Ferguson's commitment to assisting our customers obtain redress under the terms of
manufacturers' warranties is a fundamental principle of our customer service philosophy.
Ferguson does not manufacture any of the products we sell. Consequently, like our
customers, Ferguson must look to manufacturers to provide warranty protection. Our
customers' sole and exclusive warranty, therefor, is that provided by manufacturers.
Warranty Disclaimer. Ferguson Enterprises, Inc. and its subsidiaries ("Ferguson") make
no express or implied warranties. Ferguson hereby disclaims all warranties, whether
express or implied by operation of law or otherwise, including, without limitation, all
implied warranties of merchantability or fitness for a particular purpose. Ferguson shall
not be liable, directly or indirectly, for any loss, cost, damage or expense, including,
without limitation, labor charges or consequential or incidental damages, arising directly
or indirectly from the operation, condition or use of products sold by Ferguson.
Ferguson's sole liability, if any, shall be limited to the product's sale price in all cases.
Page:9/9