Loading...
Report (105) SW C. J. Hansen Co., Inc. *TRANE DEALER MECHANICAL CONTRACTORS SINCE 1948 *PLUMBING *BOILERS P.O. BOX 7397 3552 SILVERTON RD NE *MECHANICAL PIPING *HYDRONICS SALEM,OREGON 97303 *COMMERCIAL HVAC *PRESSURE VESSEL *FIRE SPRINKLER *ASME PHONE(503)362-3643,FAX(503)371-7627,EMAIL estimate@cjhansen.com *DESIGN/BUILD *CLIMATE CONTROL *24/7 SERVICE CCB 499 Special Districts Association of Oregon SDAO Office Mechanical/Electrical Systems Upgrade Submittals Section 23 80 00 - Terminal HVAC Equipment Page 1 SMACNA National Safety Award Winner +! I 15860 SW Upper Boones Ferry Rd 3990 Roosevelt Blvd.Suite A , . ia 'Rejs Lake Oswego,OR 97035 Eugene,OR 97402 Phone 503.620.4300 Phone 503.620.4300 „;-__ Hir Fax 503.620 4238 Fax 503.620-4238 airreos.com June 8,2018 SUBMITTAL Project: Special Districts Association of Oregon Tigard,OR Contractor: CJ Hansen Salem, OR Engineer: MFIA Portland, OR Section: Split System Manufacturer: Daikin AC PFDAIKINAC absolute comfort MODEL TAG FTK18NMVJU IAC-1 RK18NMVJU OAC-1 - 208V/1 - 18 SEER - Indoor unit fed by outdoor unit -Condensate Pump -Wired remote with required adaptor - Low ambient wind baffle Submitted By: Corey Elliott s 11....._Z 45 ero {= N MOO 3 CU a r N f0 11▪111111 i LitL THE MARK(4)SHOWS PIPING DIRECTION L}AIR FLOW(INDOOR) REAR 39(990mm) f -57 w U o itIll f Mk LEFT 1 I I I I RIGHT j g u s e J E UO -0 INCLUDING ` / 0- a , - i UM (MOUNTING PLATE) /% w d r " . o 10.7/161265mm) 4 -1 — r "-n r` 10-3/8(263mm) 1-15/16(50mm)MIN -� _ w.r--� �� (SPACE FOR 1-15/16(50mm)MINI cp 2 E GENERAL RATING REQUIRED SPACE SPACE FOR H2 2L � MAINTENANCE) ( � uc NAME PLATE MAINTENANCE) o 6 o c TERMINAL BLOCK = -- 9 cO `\ WITH EARTH LnLn 01 '4° :�!` � / r/{ m (� TERMINAL , II-- L ��— (INSIDE) o T BOTTOMI a) FRONT GRILLE FIXING SCREWS E UP AND DOWN WING DIRECTION ��� 1r i. _ •g Q uc (INSIDE) "/ CONTROL BLADE MOVABLE RANGE DRAIN HOSE ° E FLAPS N ABOUT 15-3/4(400mm) o 6. ,,:,.., GAS PIPE ` GAS PIPE b1/2( 12.7mm)CuT r O E E ABOUT 17-5/16(440mm) LIQUID PIPE o CU =` SIGNAL RECEIVER OUT 18-1/8(460mm) 11 t o �e OPERATION LAMP ", .�_ TIMER LAMP DRAIN HOSE LIQUID PIPE 114 6,4mm)CuT I •—r osossimmo . L 3 CO —�l INDOOR UNIT ON/OFF SWITCH * ° Q ■I-, ROOM TEMP.THERMISTOR (CONNECTING PART (� (INSIDE) LD, 69/16(614mm) ABOUT I4.3r16(360mm) E ? v cu u MODEL NAME PLATE O.D.65/8(616mm) ABCUT 14.3/8(365mm) ¢ v o BLADE ANGLES E ABOUT 17-3/4(450mm) o s o —SIGNAL TRANSMITTER E 39(990mm) o O 1-7/8(48mm) 13!16(2Dmm) UP/DOWN(AUTOMATIC) \ �-e _ I i co 29-3/8(746mm) 5(126.5mm) _ o E (.0 COOLING,DRY FAN E ^, m W DD E l .ri 15° 10" :': gad � � I m 30° v25°� u, 0 55° 70" 80° r,^ — — — — — M o c 65° = c c WALL HOLE FOR EMBEDDED PIPING c m R GHT/LEFT(MANUAL) 1-Ire(48mm) 2-3t8(60mm) WALL HOLE o o3-U8 GS80mm)HOLE � o 3-1/8(�80mm)HOLE o 1 STANDARD LOCATIONS OF WALL HOLES 15 > WIRELESS REMOTE CONTROLLER \ 'Is° 4 / 3D091781 v ,E,C (ARC480.49) I ZAIT 2 P m o c M o KJ ai z E n 7 N ......4 s' .4. U rig a a r HANDLE 9116(14) 34-1/4(870) 2-3/4(70) co 114(7) 12-5/8(320) 1-3/16(30) BRAND NAME PLATE ELECTRIC WIRE INTAKE OUTDOOR AIR THERMISTOR 1 1,901 IYy r7IN l� . mG' _ n _ `'�, MANUFACTURER'S LABEL c - in a COM C ` A ce,--N b \s„,: x� Q -.______ _ ,t.._ rA.- . 'ri I.. rfl I ll 'a 7/8(23) 'g 4-HOLES FOR FOUNDATION BOLTS 9/16(14.5) .5 c o (M8 OR M10) 23-5/8(600) "� 4-15116(125) 13-5/8(346) I 7/16(11) n a m I (INSTALLATION LEG •�a'_ °c° "-1— --- i,— PITCH) u_ a .` - 0 - 14-1/2(368) N o c o ter ' 0 0 2, O 101°' WALL HEIGHT ON AIR OUTLET SIDE ..,(CS GROUND TERMINAL 1 IoI MINIMUM SPACE FOR AIR PASSAGE v r�'� o000 0 =LESS THAN 47-1/4 co y 13 /� - -_, ,_ rt-' N C CCS _• yF_ yM___.. M •`ci, •v g Q :����- LIQUID 20-11/16(525) A v STOP VALVE �i,,iiii,,w/.4f 7,7,v,w,wr ( % E ad ;., t j ($1/4 056.4)CuT) 6 t c Qf — DRAIN OUTLET Q c GAS (LD.¢5/8(o15.9)HOSE FOR z m STOP VALVE CONNECTION WITH DRAIN JOINT) ..,,,::,' o 0 / c 0 O ® (01/2(012.7)CUT) • • / 1 v oo m o v o mY 0 Y GN o r I 1-15/16(50) m 1-15/16(50) l 1-15/16(50)CSERVICE -- E.: '- M o >oa) PORT ,14 ! T ° aEE ai„„,,,iiiv„/„„,,u - o�iii,,,,,i„,„ „„„„/, „ Illob'ik:l timamil ..0... a 11P11"111111 [2= i ciirL ] C IU w' CO C 6-13/16(173) IN CASE OF REMOVING o oN UNIT:Inch(mm) ° c > STOP VALVE COVER AND G:3D092224 TERMINAL STRIP COVER N Q z a m .o � Mc cc) U O O VI 0 d Ct cE Y c 3 _ _ ,_. , . . . - -,.. rDAIKIN i : , .t„,„<h 4. ,, -s e ct n ki ,., - X 1 .,�r^-k --i..: ;: KRP067A41E/KRP980Bi[KF P980B2E Adaptor for Wired Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing#: f-Inside indoor unit- Adaptor for t Wired Controller $602 =I S801 i Option .. .i BRC94482/ ' KRP928BB2S/ I BRP072A43/ a i �1 KRP413AB1S J 82 1 1 i tl € I =0 1 t 5403���+� tl tl i i i PCB of indoor unit 1 I i i 1 • Connects to BRC944B2 and KRP928BB2S together --Inside indoor unit-, Adaptor for Wired ! p ssot`1 I Controller ``':'2- I f € i f t I t KRP928B82S S21 I I a lil iNCO 1 SW1 SW2 0 -- 1 € l LED1 o u. ' € 11=1I ass SW3 , S403 t � Tessa , S1 S8 SS I r]� S16 S19 Vo as 00® i- ■1111110 i i PCB of indoor unit I i i I T s i O. *Additional cable(BRCW901A08/DACA-BRCW901P10/DACA- BRC944B2 BRCW901P25)is needed(The Wired Remote Controller Kit BRC944B2-A08 includes both the controller BRC944B2 and the cable BRCW901A08.) Daikin North America LLC,5151 San Felipe,Suite 500,Houston TX,77056 www.daikinac.com www.daikincity.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 2 of 3 1 i rDAIKIN lCRl O67A41 E/KRP98t3B'tit( 87043'''2E Adaptor for Wired Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing#: DOCUMENTATION: Documentation available on www.daikincity.com and/or www.daikinac.com: • Submittal • Installation Manual Daikin North America LLC,5151 San Felipe,Suite 500,Houston TX,77056 www.daikinac .com www.daikincitv.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 3 of 3 rDAIKIN ASPEN. PUMPS SUBMITTAL DATA SHEET (Sec.II)Ordering Information: Product Code—DACA-CP4-1 Model—DACA-CP4-1 Mini White Univolt Carton Qty- 1 Mini-Split Condensate Pump Kit 100-250v Carton Weight 1.5 DACA-CP4-1 (Sec.III)Carton Contents: Project Information: Monobloc Pump Assembly Hose Clamp Job Name: 39"Power Cable Anti-siphon (1) Location: Inline Fuse Installation Manual Engineer. Wall Anchors(3) Submitted to: Screws (3) For: ❑ Reference ❑ Approval ❑ Submitted by: (Fig.I)Product Image: Reference: Submittal Information: Approval: bate: Construction: Unit#: 0111110 "'`""`.-,.., Drawing#: (Sec.I)Product Specifications: Pump Length—7.125" (Fig.II)Typical Pump Locations: Pump Width—2" Pump Height—4.5" Capacity-2.9 GPH @ 0'Head/1.2 GPH @33' Head EVAPORATOR COIL Max BTUs-54,000 _ Max Head in Feet-39 ���������m�� '-------rata—rani' Max Temperature- 104F ���M���M=gym-._ CONDENSATE — —���--��—� Max Suction Lft- N/A DRAIN TRAY Sound Level-21 dB(A) Dry Contact Rating- 3A NC Voltage- 100-250v a b 6 J� Amperes- .17 i Watts- 16 1. I Remote Reservoir-Y L.-- _ Plenum Plenum Rated—N Cable Length—39" Supply level and pump performance varies with voltage frequency. (Recmrseai•5 products are sutiiecr to coritinuaus inpxovements;Rectors reserves the not to molly product design,specifications&information in this data sired wihort notice and without irxuning arty ohfigations) Pump Selector&Wiring Diagrams Available ASPEN'Is a registered trademark of Aspen Oldco Limited Company UK Mini White is a registered trademark of Aspen Pumps Limited Company UK at http://www.rectorseal.com/aspenpump.html Contact:RectorSeal® 2601 Spenwick Drive,Houston,TX ® 713-263-8001 800-231-3345 0 713-263-7577 i 800-441-0051 ® vvvvw.rectorseal.com H-AP-S-17 2417 Rectorseal. Mini White Univolt r Mini-Split Condensate Pump Kit 100- "' .. 250v Aspen Pump BTU Calculator l���a,MZ Mini White 115v 60Hz Mini Blanc 115v 60Hz 4U Head GPH BTU 0 3.2 54600 5 2.9 49500 10 2.6 44350 ILL) ,......_._._ 15 2.4 42000 20 2.2 37500 25 1.9 33250 0 . 30 1.7 29250 1.4 1.7 2 2.3 2.6 2.9 3.2 33 1.6 27500 Flow Rate(GPH) Mini Blanc 230v 60Hz Mini White 230v 60Hz "W�""Z Head GPH BTU 0 2.9 49500 3U 5 2.5 42600 10 2.2 37500 ft o 15 2 34000 20 1.8 30700 25 1.6 27500 . 0 , 30 1.3 22400 1 1.2 1.4 1.6 1.82 2.2 2.4 2.6 2.8 3 3.2 33 1.2 20600 Flow Rate(GPH) I Contact:RectorSeale 2601 Spenwick Drive,Houston,TX 0 713-263-8001 1800-231-3345 0 713-263-7577 1800-441-0051 0 www.rectorseal.com 2017 PectorSeal® H-AP-S-17