Permit (52) CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT
COMMUNITY DEVELOPMENT Permit#: FPS2018-00075
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/31/2018
T l ;.1 I' f_7 9
Parcel: 2S113BA00400
Jurisdiction: Tigard
Site address: 7632 SW DURHAM RD 300
Project: Bridgeport VSP Subdivision: None Lot: None
Project Description: Fire sprinklers:Relocating(8)sprinklers for TI.
Contractor: PATRIOT FIRE PROTECTION INC Owner: PORTLAND SW CENTER LLC
4708 NE MINNEHAHA ST BY FELTON PROPERTIES INC
VANCOUVER,WA 98661 ATTN: FELTON, MATT
520 SW 6TH AVE, STE 610
PORTLAND, OR 97204
PHONE: 360-699-4403 PHONE:
FAX: 360-699-4485
FEES
Description Date Amount
Specifics: Permit Fee-COM 07/13/2018 $69.92
12%State Surcharge-Building 07/13/2018 $8.39
Type of Use: COM Plan Review-Fire Life Safety-COM 07/13/2018 $27.97
Class of Work: ALT Type of Const: VB Info Process/Archiving-Sm$0.50(up to 07/13/2018 $0.50
Occupancy Grp: B Height: ft 11x17)
Stories: 1
Commercial Sprinkler System:
Sprinkler Required: Yes Sprinkler Type: Wet
Standpipe Required: Hazard: ORD1
Density: 0.1 Design Area: 1500
K Factor: 5.6
Commercial Fire Alarm System:
Fire Alarm Required: Alarm Type:
Pull Station Required: Smoke Detectors Req:
Battery Calcs Provided: Cut Sheets Required:
Total $106.78
Valuations: Required Items and Reports(Conditions)
Sprinkler Valuation: $1,200.00
Residential Square Footage: 0
Fire Alarm Valuation: $0.00
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon
Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules
or direct questions to OUNC by calling 503.232.1987
or 1.800.332.2344.
Issued By: �' ' / Permittee Signature: 5
Call 503.639.4175 by 7:00 a.m,for the next available inspection date. *€-717) e.-4-7 (---
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
City of Tigard Permit No.: FP�/�+0la liC 7 S`
II 'll 13125 SW Hall Blvd.,Tigard,OR 9RECEIVED
Phone 503.718.2439 Fax: 503 q 2°1 AV Date Received: AV
Inspection Line: 503.639.4175 ,JUN N / —
1 IC,1 l:U Internet: www.ti and-or. ov q B . +,7 /
g g COT °�" T�Gr�� y
pp1VtSt�'v
FIRE SPRA-FFIDAVIT FOR ALTERATIONS
OR TENANT IMPROVEMENTS
(1 to 10 SPRINKLER HEADS WITHOUT PLANS)
Project Name: Bridgeport VSP Occupancy: B
Job Address: 7632 SW Durham Ava, Tigard 97224 •Type of Construction: 2-B
Suite: 3 0 0
Contractor: Patriot Fire Protection, Inc Phone: 360 699 4403
Number of Proposed or Altered Heads: 8
Type: SSP Hazard: light Density:. 10
I, Joseph Plattner Oregon Construction Contractors Board No. 70822
certify the following is true and reasonably defines the scope of work for this project:
a) All work is limited to drops and armovers in a light-hazard occupancy.
b) Positions of sprinkler heads relative to architectural features such as soffits, beams, partitions, walls, etc.
complies with current adopted edition of NFPA 13.
c) The proposed work does not require hydraulic calculations.
d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be
installed when each head is in a separate fire area).
e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13.
f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13,
Section 8.3.3.1 for exceptions).
g) The installation shall comply with the requirements of the current adopted edition of NPFA 13.
h) Piping shall not be concealed until hangers and bracing are inspected.
i) Final approval shall be subject to onsite tests and inspections.
In addition,I understand the following is required:
• Submit(3)copies of a sketch showing the area of work within the building's structure.
• Building fire protection system permit.
• A copy of this document with a copy of the sketch attached shall be available for all inspections.
Signature: c Date: 6-2 2-18
Print Name: Joseph Plattner •
I:1Building\Fonns\FireSprinklerAffidavit 071514.docx Page 1 of 1