Loading...
Specifications \( q OFFICE COPY Structural Calculations for nE„-,1-ac n L9171 Residential Remodel for r) JUL 1 6 2018 10319 SW Picks Way CITY OF Portland, OR 31JILDING TY,"SION.1 June 25 2018 DESIGN CODE 2017 Oregon Residential Specialty Code DESIGN LOADS Gravity Loads Material Wt lbs (Dead) 40 psf (Live- Floor) 25 psf (Live - Snow) Seismic, SDS 0.712 g Wind, Exposure"B" 120 mph oktv PROps, 6'2 ..1„c, Ne0 As 4' 2 PEI/- CONTENTS OREGON Gravity/ Lateral Calcs '<sv„ 14 , v4LA S EXPIRES: 12/31/20 SCOPE OF WORK The attached calculations pertain to gravity and lateral analysis for a new header on the first floor East wall at the above address. This scope of work does not include any analysis of any other portions of structure to remain. LHAYDBY RN DATE 6/25/18 EN ENGINEERS REV DATE STRUCTURAL I CIVIL JOB NO 18187 (503) 968-9994 p (503)968-8444 f SHEET I OF 9 ' _ 24,-_,„tr.-, _i't t- j J z f , // 7 9 _...... BY DATE 6473',v.-Pe IEHAYDEN __ .._ ...... f' E'r, 1 -r,r its . 3ENGINEERS ___ _ .. REV DATE STRUCTURAL I CIYIL .. -----.........._...__._. _...__ JOB NO 1,47 _.. (503) 968-9994 p (503) 968-8444 f SHEET A OF 3 HAYDEN ENGINEERS STRUCTURAL I CIVIL Wood Beam File=Zaprolecisl2Q18PR-11181871-11CALCUL-1118187•-1.EC6 i iic.#;`KW-06005543 , Licensee,eHAYDEN CONSULTING ENGINEERS Description: Header • CODE REFERENCES Calculations per NDS 2012,IBC 2012, CBC 2013,ASCE 7-10 - Load Combination Set : ASCE 7-10 Material Properties Analysis Method: Allowable Stress Design Fb+ 900.0 psi E E. Modulus of Elasticity Load Combination ASCE 7-10 Fb 900.0 psi Ebend-xx 1,600.0ksi Fc-Pr!! 1,350.0 psi Eminbend-xx 580.0ksi Wood Species : DouglasFir-Larch Fc-Perp 625.0 psi Wood Grade : No.2 Fv 180.0 psi Ft 575.0 psi Density 31.20pcf Beam Bracing : Beam is Fully Braced against lateral-torsional buckling DLO O675xLt0,1si DLO 11867) a D(0 068)S(0 1� _ '17(0'0g81,0_70.4487814.1,0 o I I 4x10 AN Span=8,0ft i Applied Loads Service loads entered. Load Factors will be applied for calculations. _ Load for Span Number 1 _.._ Uniform Load: D=0.0170, S=0.0250 ksf,Extent=0.0-->>5.250 ft, Tributary Width=4.0 ft,(Roof) Varying Uniform Load: D=0.0170->0.0170, S=0.0250->0.0250 ksf,Extent=5.250--»8.0 ft, Trib Width=4.0->2,625 ft,(Roof) Uniform Load: 0=0.010 ksf, Tributary Width=11,667 ft,(Wall) Uniform Load: D=0.0150, L=0,040 ksf, Tributary Width=4.50 ft,(Floor) DESIGN SUMMARY Desi n OK, Maximum Bending Stress Ratio = 0.76G 1 Maximum Shear Stress Ratio = 0.360 : 1 Section used for this span 4x10 Section used for this span 4x10 fb:Actual = 827.70 psi fv:Actual 64.72 psi FB:Allowable = 1,080.O0psi Fv:Allowable _ 180.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 4.000ft Location of maximum on span .. 0.000 ft Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1 Maximum Deflection Max Downward Transient Deflection 0.045 in Ratio= 2124>=360 Max Upward Transient Deflection 0.000 in Ratio= 0<360 Max Downward Total Deflection 0.115 in Ratio= 835>=240 Max Upward Total Deflection 0.000 in Ratio= 0<240 l Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.841 1.789 Overall MINimum 0.603 0.588 AYDEN ENGINEERS STRUCTURAL I CIVIL I Wood Beam Fate=Z:iprojecls12018PR-11181871-11CALCUL-1118187—1,EC6 LIG.# ° W-0600564 ' v Licensee:HAYDENO ULTING ENGINEERS`. Description: Header • Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 D Only 1.005 0.980 +D+L 1.725 1.700 +D+S 1.400 1.338 +0+0.750L 1,545 1.520 +0+0.750L+0,750S 1,841 1,789 +0.60D 0.603 0.588 Wind and Seismic Design ASCE 7-10 Seismic Base Shear Loading Risk Category II V= Cs W (ASCE 7-10 EQ. 12.8-1) Cs= SDS (ASCE 7-10 EQ. 12.8-2) R/le SDS 0.712 g (USGS Design Maps Summary Report) R 6.5 (ASCE 7-10 Table 12.2-1) Risk Category 2 le 1.00 (ASCE 7-10 Table 1.5-2) V= 0.110 W (ASD) V= 0.077 W (ASCE 7-10 Sect. 2.4.1) Wind Loading 120 mph Exposure B Ps= AKZtPs3o (ASCE 7-10 EQ. 28.6-1) Mean Roof Ht. 25 ft Roof Pitch 8 = 34 Degrees Ps30 (wall) 25.7 psf (ASCE 7-10 Fig. 28.6-1) Ps3o (roof) 17.6 psf (ASCE 7-10 Fig. 28.6-1) A 1.00 (ASCE 7-10 Fig. 28.6-1) KZt 1.0 (ASCE 7-10 Sect. 26.8.1) ps(wall)= 25.700 psf Ps(roof)= 17.600 psf (ASD) ps(wall)= 15 psf (ASCE 7-10 Sect. 2,4.1) (ASD) ps(roof)= 11 psf (ASCE 7-10 Sect. 2.4.1) BY RN DATE 6/22/18 13 HAYDEN ENGINEERS 10319 SW Picks Way REV DATE STRUCTURAL I CIVIL jOT NO 18187 (503)968-9994 p (503)968-8444 f SHEET 6" OF --1 __4- 4 .�I ctv o PO x i1 b � i s tri E 7-' 44 r 1-4,::--4), _ ; , \,:r. i 1 I ) i • 1---'s\ft -,.. 1 I. It it t , } ‘4 1 ' Of 44 f/ 3) t y/ .,,,:#41,7 Alf�) ' /11:5 ..,41/ ( ) = / FL1ji7; ---- Sortr- . 67/7 , HAYDEN , /FA/ DATE irli,//, ENGINEERS /7:,.)/.;:" ,-5, ) ( , � ; � ,E REV 1331( DATE_.__ .. STRUCTURAL I CIVIL JOB NO /7/d., (503) 968-9994 p (503) 968-8444 f SHEET 7 OF • Lateral Analysis • Wind Controled Upper Wall Length 1 30.0 ft Wall Height 8.0 ft Reaction 3819 lb Wall Wt. 10 psf Roof Wt. 17 psf Roof Tributary 4.0 ft v = 127 lb/ft y —4 Nail Sheating at 6 in o/c M Edge & 12 in o/c Field overturning= 30552 ft-lb MReaction Wall= 21600 ft-lb MReaction Roof= 18360 ft-lb Tasd= -314 lb —4 No Strap Req. Lower Wall Length 1 19.3 ft Wind Controled Wall Height 9.1 ft Reaction 6462 lb Wall Wt. 10 psf Floor Wt. 15 psf Floor Tributary 4.5 ft v = 336 Ib/ft —+ Nail Sheating at 6 in o/c M Edge & 12 in o/c Field overturning= 58697 ft-lb MReaction Wail= 10098 ft-lb MReaction Floor= 7504 ft-lb Tasd= 2135 lb —* USE Post Installed 16 Ga. Strap Tuft = 3558 lb BY RN DATE 6/22/18 ra HAYDEN ENGINEERS 10319 SW Picks Way REV DATE STRUCTURAL I CRU. JOB NO 18187 (503) 968-9994 p 1503) 968-8444 f SHEET OF Custom Hold,Down Strap Design wi(2)Thru-Bolts Thru Conc. Bolts Concrete 0= 1/2 in (Bolt Diameter) f'�= 2500 psi rn/f)= 2.65 kip (Bolt Capacity) b = 6 in (Wall Width) 0= 0.75 ASD Factor= 0.6 Wind Controled Strap 16d Nail/SDS Screw Capacity Strap Size 16 Ga. (Strap Thickness) Pnail = 164 #/ nail t= 0.0566 in (Strap Thickness) Pscrew= 250 #/screw w= 3 in (Strap Width) Cd= 1.6 duration factor fy= 50 ksi fu = 65 ksi shy= 1.67 Applied Load = 2 Tmax= 2135 lbs (ASD) Ag= 0.170 An= 0.142 Check Yelldinp Check Tension Ty = Agfyfu = 5.08 kip Tu A = 4.60 kip y u • TAllowable= Min (Ty, T„) = 4.60 kip > Tmax= 2.134794 kip Strap OK And Bolt Capacity= 2.65 kip > Tmax= 2.134794 kip Bolt OK Check Bolt Depth Into Conc, d►ne►� = T"` 6.00 in *Note: This calculations assumes 1/2 of the 4*0*Fr, * 6* (ASD) tension load(Tmax) to the top bolt. Use 6" Nail/Screw Reuirment NailReq = P amaxCd = 8.1 Nails TScrew "` = 5.3 Screws Req = 'screw * Cr! --> USE 16 Ga. Strap w/(2) 1/2 in. 0 Bolts, Placed @ 6 in. min. below top of stem wall. And, (9) 16d Nails -OR- (6) 1/4 in. x 3 in. Simpson 'SDS' Screws Into DBL. Stud min. BY RN DATE 6/22/18 ENGINEERS 10319 SW Picks Way REV DATE STRUCTURAL I CIVIL JOB NO 18187 (503)968-9994 p (503)968-8444 f SHEET 9 OF 9