Plans (99) t" ,) )...) la \ F� c-t 6,v�_�,y r.; Submittal - /0 �� . Single Packaged Heat Pump 14 SEER Convertible 4WCC4024A1000A ,ice CI'T'Y OF TI ARD ������ iii REVIEWED FOR CODS COMPLIANCE %%%% Approved: rX1 \ Nkz - OTC: [ [ \ -� Permit ##: �-- ='I -114 .._ _.r. Address: 0 Shite #: o • i � By: rip, Date:' Note:"Graphics in this document are for representation only.Actual model may differ in appearance." OFFICE COPY TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. January 2015 4WCC4024A-SUB-1 B-EN OW Ingersoll Rand Product Specifications MODEL 4WCC4024A1000A OUTDOOR FAN—TYPE SWEPT RATED Volts/PH/Hz 208-230/1/60 DIA.(IN.) 23.4 Performance Cooling BTUH(a) 24600 DRIVE/NO.SPEEDS DIRECT/3 Indoor Airflow(CFM) 758 CFM Co 0.0 in.w.g.(e) 2550 Power Input(KW) 1.9 Motor—HP/R.P.M 1/12/850 EER/SEER(BTU/Watt-Hr.)(b) 12.00/14.00 Volts/Ph/Hz 208-230/1/60 Sound Power Rating[dB(A)](c) 66.4 F.L.Amps/L.R Amps .54/.82 PERFORMANCE HEATING INDOOR FAN—TYPE CONSTANT TORQUE ECM (High Temp.)BTUH 22000 Dia.x Width(In.) 10.62 X 10.68 Power Input(KW) 1.8 Drive/No.Speeds DIRECT/3 (Low Temp.)BTUH 14300 CFM @ 0.0 in.w.g.In SEE FAN PERF TABLE Power Input(KW) 1.12 Motor—HP/R.P.M. 1/3/1050 HSPF(BTUH/Watt-Hr) 8.0 Volts/Ph/Hz 208-230/1/60 POWER CONN.—V/Ph/Hz 208-230/1/60 F.L.Amps 2.8 Min.Brch.Cir.Ampacity(d) 19.4 FILTER/FURNISHED NO Fuse Size—Max.(amps) 30 Type Recommended THROWAWAY Fuse Size—Recmd.(amps) 30 Recmd.Face Area(sq.ft)(s) 2.7 COMPRESSOR SCROLL REFRIGERANT 8-410 VOLTS/PH/HZ 208-230/1/60 Charge(lbs.) 5.74 R.L.Amps—L.R.Amps 12.8/58.3 CHARGING SPECIFICATIONS OUTDOOR COIL—TYPE SPINE FIN Subcooling 16' Rows/F.P.I 2/24 DIMENSIONS H X D X W Face Area(sq.ft.) 13.32 Crated(in.) 46 X 45 X 52 Tube Size(In.) 3/8 WEIGHT Refrigerant Control EXPANSION VALVE Shipping(lbs.)/Net(lbs.) 402/328 (a) Rated in accordance with AHRI Standard 210/240. INDOOR COIL—TYPE PLATE FIN (b) Rated in accordance with D.O.E.test procedure. Rows/F.P.I 3/15 (C) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. Face Area(sq.ft.) 3.5 (d) Calculated in accordance with currently prevailing Nati Electrical Code. Tube Size(in.) 3/8 (e) Standard Air—Dry Coil—Outdoor. (f) Standard Air—Dry Coil—Indoor Refrigeration Control EXPANSION VALVE (s) Filters must be installed in return air stream.Square footages listed Drain Conn.Size(in.) 3/4 FEMALE NPT are based on 300 f.p.m.face velocity.If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05"W.C. 2 4WCC4024A-SUB-1 B-EN Outline Drawings Figure 1. 2—3 TON MODELS - 1240.28 - (48-21/321 11.56 - C i (15/32] INLET (DUCT FLANGE) J i 1 f WS. le W3 1049.02 "*::,-,..-- \ (41-5/161 �_ ■rI ry/ � 1 -OWLET-P. ■Il lih10,110/p I'�I������)1�� INLET 1 1 WI W4 INLET TOP SIDE ENTER OF GRAVITY 4 OUTLET _ - ... • • Nom . 25.401- 5.407 I— - - (1 1 469.93 —.1 ONDENSATE DRAIN FOR FRONT SIDE (18 I/2] 19.0 (3/41 FEMALE NPT LEFT SIDE 1' L. • ' 1 18.03 . ,,,gi [23/32] [23/32] .f.I.E) 14.2(9/161 Y LY SECTION Y•Y 1 # // TYPICAL ID)SIDES OF DONNFLON DUCT OPENINGS111111 I ', Note:The view labeled Bottom Side represents the base as viewed looking BOTTOM SIDE up from underneath the unit. 4WCC4024A—SUB-1 B-EN 3 Outline Drawings Figure 2. 2-3 TON MODELS Al a /-T0- r \ 0-=-- 62 o N (96-11/16] 0 �� (OUTSIDE) ill , ►. I 1''� 58. 19 .1'...'1,1 \`/ RETURN [2-9/32] SU r 55 171. 398.22 19.50 J" (15-1I/16] (3-1/8) (OUTSIDE) 398.22 176.01 [15-11/16] (6-15/16] (OUTSIDE) T l , ,-1' BACK DUCT OPENINGS a .1 I • 530 49 1 • . [20-1/81 17.178 (11/16] X X SECTION X-X 1 1155.45 1 [45-1/21 TYPICAL 18) SIDES OF SIDEFLOW DUCT OPENINGS (SURFACE AREA/ BACK SIDE APPROX.CORNER WEIGHT TOTAL CENTER OF GRAVITY Height MM/IN KG/LBS SHIPPING UNIT MM/IN. Model WIGHT WIGHT A W1 W2 W3 W4 KG/LBS KG/LBS B C 58.3 36 8[81] 26.1 41.0 196.1 162.4 479.8[18.9] 527.8 8 4TCC4024 898.53[35-3/8] [129][ 58] [90] (432) (358) L20' ] 61.3 38 7[85] 27.5 43.1 204.8 171.1 406.5[16.0] 594.1 [23.4] 4TCC4030 [135] [61] [95] (451) (377) 61.738 9[86] 27.7 43.7 205.7 172.0 414.3[16.3] 697.6[27.5] 4TCC4036 949.33[37-3/8] [136] [61] [96] (453) (379) 52.9 33.3[73] 24.1 38.3 182.3 148.6 430[16.9] 565.3[22.3] 4WCC4024 [117] [53] [84] (402) (328) 55.3 16.6 39.2 195.0 161.3 4WCC4030 1050.93[41-3/8] [122] 50.3[110] [37] [86] (430) (355) 413.5[16.3] 581 [22.9] 59.6 37 3[82] 26.6 41.7 199.0 165.3 430[17.0] 535[21.1] 4WCC4036 [131] [59] [92] (439) (364) 4 4WCC4024A-SU B-1 B-EN Outline Drawings Figure 3. 2-3 TON MODELS [,, iiiik.\...:..._.-",. ,,,,,.._____. __-----441!!!!Fr i o • %` 304.80 0011•---"_.......--.4: ��� 173.46 [12] \ 1 RETURN [6-27/32] (INSIDE) \�[� 406.40 75.41 SUPPLY [16] [2-31/32] �� (INSIDE) 75.41 167.89 [2-31/32] [6-5/8] 406.40 [16] (INSIDE) BOTTOM DUCT OPENINGS RECOMMENDED SERVICE CLEARANCE MM/IN. NITN ECONOMIZER BACK SIDE 304.6(121 762.0(301 LEFT SIDE 762.0(301 914.4 136] RIGHT SIDE 609,6(241 - FRONT SIDE 1066.3 1421 - CLEARANCE TO COMBUSTIBLE MATERIAL MM/IN. A ......77=. NNP-....r BOTTOM 0 BACK SIDE 25.4(II LEFT SIDE 152.4 16] RIGHT SIDE 152.4 161 FRONT SIDE 304.0(121 24V ENTRY •• . - - ` �• • TOP 914.4(361 359.19 [14- /32] f t wc 288.42225.68 [II-11/32] [8 /8] '441hIL . --I : I I7. 73 POWER ENTRY [4-5/8] 28.58 [I-I/81 DIA. KNOCKOUT 85.22 y ~ POWER ENTRY [3-11/32] 28.58 [I-I/81 DIA. KNOCKOUT 34.93 (1KNOCKOUT ---..... Lo-- 128.08 50.01 (1-31//32D]IA.DIA. KNOCKOUT [5- 1/32] SINGLE POINT ENTRY 34.93 (IKNKOUT RIGHT SIDE 50.01 (1-31/83201 DIA.A. KNOCKOUT 62.71 [2-15/32] DIA. KNOCKOUT 4WCC4024AA-SUB-1 B-EN 5 Indoor Fan Performance (230v) Table 1. Horizontal Airflow 4WCC4024A1 EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 WATTS 63 70 77 83 90 95 - - - - - LOW CFM 899 820 755 681 581 505 - - - - - WATTS 75 83 91 97 104 111 - - - - - MEDIUM CFM 959 886 818 756 673 589 - - - - - WATTS - - 119 127 134 142 149 155 - - - HIGH CFM - - 940 886 820 748 670 605 - - - Table 2. Down Airflow 4WCC4024A1 EXTERNAL STATIC PRESSURE(IN.WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 COOLING WATTS 63 71 77 83 90 95 - - - - - -LOW CFM 890 811 747 674 575 500 - - - - - COOLING WATTS 76 84 91 98 105 112 - - - - - -MED CFM 950 877 810 749 666 583 - - - - COOLING WATTS - - 119 127 135 143 150 156 - - - -HIGH CFM - - 931 877 812 741 663 599 - - - 6 4W CC4024A-SU B-1 B-EN Full Perimeter Roof Mounting Curb Figure 4. 4024—4036 Models BAYCURB050A Full Perimeter Roof Mounting Curb 17 7/8 46 3/8 �� • 3 RETURN3 AIR `o 5/8 i SUPPLY �♦ AIR `� 191/2 2 3/16 38 19 1/2 I. 15 i `� /1 7/8 14 1 1/2 The drawings on this page are prepared by the • manufacturer in order to provide detail regarding /" job layout only.These drawings are not intended to /•• •• be used as a basis to construct, build or modify the /" items depicted in the drawings.The manufacturer /• is not responsible for the unauthorized use of these /�A B "� drawings and expressly disclaims any liability for /•• "•., damages resulting from such unauthorized use. • /• • < 411;* , .. •• ' \ '. SUP "\ P - D C CHANNEL SIDE CHANNEL END 10110,..„-- WOOD NAILER SERVICE CLEARANCE DIMENSIONS • HOLE IN ROOF A B C D ‹. WCe/TC* 42.00 36.00 12.00*• 24.00 433/8 DC*/YC* 42.00 36.00 12.00** 36.00 35 7/8 **42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4WCC4024A-SUB-1 B-EN 7 Supplementary Electric Heater Table 3. BAYHTRV—Supplementary Electric Heaters HEATER MAX.FUSE CANADA ELECTRIC RATED NO. KW/STAGE UNIT HEATER VOLT- PHASE AMPS CAPACITY OF MCA OR HACK ONLY MAX. MODEL MODEL AGE STAGES CKT BKR CKTBKR KW BTUH 1 2 SIZE SIZE 4024-4060 BAYHTRV105 208/240 1 18/21 3.76/5.0 17100/ 1 3570/ - 23/26 25/30 25/30 6.0 4024-4060 BAYHTRV108 208/240 1 29/33 6.0/8.0 27300 1 8 0/ - 36/41 40/45 40/45 7.5/ 4024-4060 BAYHTRV110 208/240 1 36/42 7.5/10.0 34100/ 1 10.0 - 45/52 45/60 45/60 4030-4060 BAYHTRV115 208/240 1 54/63 11.27/ 38500/ 2 7.5/ 3.76/ 68/78 70/80 70/80 15.0 51200 10.0 5.0 4048-4060 BAYHTRV120 208/240 1 72/83 15.0/ 51200/ 2 7.5/ 7.5/ 90/ 90/110 90/110 20.0 68300 10.0 10.0 104 4060 BAYHTRV125 208/240 1 90/ 18.78/ 64100/ 2 11.26/ 7.5/ 113/ 125/150 125/150 104 25.0 85300 15.0 10.0 130 Table 4. BAYSPEK—Single Power Entry Kit SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION UNIT MODEL SINGLE POWER HEATER MODEL MIN CKTAMP MAX OVER-CURRENT DEVICE ENTRY KIT BAYHTRV105 45 50 BAYSPEK60 4WCC4024A BAYHTRV108 60 60 BAYSPEK62 BAYHTRV110 71 80 8 4WCC4024A-SUB-1 B-EN Optional Equipment — Filter Rack Figure 5. BAYFLTR101 Filter Rack(4024-4036) BAYFLTR201 (4042-4060) (Mounts in Filter/Coil Section) .1171.111(1 -.: ----ti Figure 6. BAYACCDORIA Hinged Filter Access Door(4024-4036) BAYACCDOR2A(4042-4060) Replaces Filter/Coil Access Panel 41111111 ' IIA1111 11111 \umilia---t-3 ----------- \ - \\ IlLr i 1 Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4WCC4024A—SUB-1 B-EN 9 Optional Equipment — Filter Rack Optional Equipment — Economizer Table 5. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC UnitUnit Application Economizer \ Models / ' Economizer ; eeeeeaeeaee rain hood ; ®®o®®®®® o o a as e a a a`aa A=0 0 0 0 o o BAYECON 101A 4024-036 � • � •�.i Outside air, 11 dampers / `1 r.-1-' Return air 1 dampers / Required `N c A\ ,�filter kit,order Mist N. o 2 i separately eliminator - 1 % BAYECON102A 4042-060 Relief —Return damper Duct Roofcurb/ 4‘.___. Table 6. BAYCON200,201A Horizontal Economizer and Rain Hood � 1 1 Ir� < 41 Economiz900.. i►, I. C' \_II/ I I'C'I ._y'0.11111°. -/ Gaskets(2) Duct � �I` 111 -4— Rain Hood 'rks. 1 / Mixed Air Sensor Economizer Models A B C D E F BAYECON200AA 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201AA 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 10 4WCC4024A-SUB-1 B-EN Optional Equipment — Filter Rack Optional Equipment — Outside Air Damper Table 7. BAYOSAH001 and 002A I� Manual Fresh Unit Air Model Application A B C D A Models ''-)1' `I FULLY opENABAYOSAHOO1A 4024-4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" FULLY s CLOSED BAYOSAHOO2A 4042—4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 8. BAYDMPR101 and 102A,25%Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) Manual Fresh Unit Air Model Application A B C D A Models `:111 A1- BAYDMPR101A 4024—4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" i r e //Ir i — / BAYDMPR102A 4042—4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" 4 D Note:The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.These drawings are not intended to be used as a basis to construct,build or modify the items depicted in the drawings.The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4WCC4024A-SUB-1 B-EN 11 Mechanical Specifications General have thermal overload protection and permanently The units shall be horizontal airflow as shipped and lubricated motor bearings.Motor/blower assembly convertible to downflow.All units shall be factory isolated from unit with rubber mounts. assembled,piped,internally wired and fully charged Outdoor Fan with refrigerant.Units shall be certified to UL Standard One direct-drive,statically and dynamically balanced 1995.All units shall be factory run tested to check propeller fan shall be used in a draw-through vertical cooling operation,fan and blower rotation and control discharge configuration.Permanently lubricated or TXV sequence.Units shall be designed to operate at weather proof motor shall have built-in thermal ambient temperatures between 115°F and 55°F in overload protection. cooling as manufactured.Cooling performance shall be rated in accordance with AHRI standards. System Controls Unit Casing System controls include condenser fan,evaporator fan All components shall be mounted in a weather- and compressor contactors. resistant steel cabinet with an enamel finish.Access Accessories Roof Curb panels shall be provided for unit controls and indoor The roof curb shall be designed to mate with the unit coil and fans.Indoor air section compartment shall be and provide support and complete weathertight completely insulated with fireproof,permanent, installation when properly installed.Adhesive back odorless fiber material.Knockouts shall be provided for polyurethane sealing strips shall be provided to ensure utility and control connections.Drain connections shall an airtight seal between supply and return openings of be provided to accommodate indoor water runoff. the curb and unit.The roof curb design allows field Compressor fabricated ductwork to be connected directly to the The compressor shall be hermetically sealed,high curb.Curb ships knocked down for field assembly,and includes factory installed wood nailer strips. efficiency scroll compressors.Internal overcurrent and over temperature protection,internal pressure relief Electric Heaters shall be standard.Other features include centrifugal oil Each heater assembly shall include power supply pump,low vibration and noise. fusing if over 48 amps,automatic resetting limit Refrigeration System switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick All units shall have refrigerant control.Service pressure connection to unit low voltage wiring.Electric heat tap ports and a refrigerant line filter shall be standard. modules shall be UL listed. Evaporator Coil Internally enhanced 3/8"OD seamless Single Source Power Entry copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 480—650 psig.All This accessory when used with electric heat accessory units have TXV to control refrigerant flow. shall allow single source power connection to unit and heater combination.Single source power entry kits Condenser Coil shall have specific matching heater(s).Kit shall include The Spine Fin TM condenser coil shall be continuously high voltage terminal blocks,fuse blocks and fuses,cut- wrapped,corrosion resistant all aluminum with to-length interconnecting wiring,and junction box(if minimum brazed joints.This coil is 3/8"OD seamless required)to provide power sources with fuse aluminum tubing glued to a continuous aluminum fin. protection as required for both the unit and accessory Coils are lab tested to withstand 2.000 pounds of heater.Kit components shall install within the heater pressure per square inch.The outdoor coil provides cabinet in the heater access section.Single source low airflow resistance and efficient heat transfer.The branch power circuit shall be protected and wired in coil is protected on all four sides by louvered panels. accordance with local codes. Indoor Air Fan Constant Torgue,forward-curved,centrifugal wheel in a Composite Vortica®Blower housing.Motor shall 12 4WCC4024A-SUB-1B-EN Mechanical Specifications Fully Modulating Economizer Start Kit This accessory shall be field installed and be composed Extra compressor starting capacity for single phase of the following items:0-100%fresh air damper, equipment. damper drive motor,fixed dry bulb enthalpy control, Control Options and low voltage pigtails for electrical connections. Standard Indoor Thermostats Solid state enthalpy or differential enthalpy control is optional.Economizer operations shall be controlled by Two stage heating/cooling or one stage heating/cooling the preset position of the enthalpy control.A thermostats shall be available in either manual or barometric relief damper shall be standard with the automatic changeover. economizer and provide a pressure operated damper Programmable Electronic Night Setting Thermostat that shall be gravity closing and prohibit entrance of Programmable electronic thermostat shall provide outside air on equipment"off"cycle.Economizer heating setback and cooling setup with 7-day requires BAYRLAY004A relay lotto interface the programming capability.1H/1C or 2H/2C models economizer to the heat pump. available. Manual Outside Air Dampers Rain hood and screen shall be field installed.Suitable for up to 25%outside air. ti.�1 CERTIFIED., www.ahridirectory.org C us Unitary Small HP AHRI Standard 210/240 n zppries Dost wnen Ne mmrlere system Intertek The manufacturer optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 02014 Trans 4WCC4024A-SUB-18-EN 15 Jan 2015 T_ Ingersoll Rand Supersedes 4WCC4024A-SUB-1A-EN (October 2014) DI IENSIO ED ANDTOIERENCED POURS!T14.NLIN2 REVISIONS REV. DESCRIPTION DATE APPROVED Attn: Tag: 1 INITIAL DWG 1/9/11 SRP 2 REDUCED HEK,Hf I-ROM 16"10 12"ADDED SUPPLY 6/31/17 00 WAIT PFR MG Approval: 17" � SUPPLY AIR y ...--3" RETURN AIR 32 3/4" , � v 3712" INSULATED ,� ' �` COVER �y�►-- 4i 0.001, EXISTING CURB LAYOUT 81 3/4" `'• I, 2 1/4" 17 9/18" 1 I- 40" r_2 1/4" 331/4" (SUPPLY 1 36 1/4" I f 537/16" 51 3/16" ( RETURN �[ I 4115/16"-01 r 92 1/4" 531/4" F ._ 1 1 L 12" r 831/4" - 1 3„ FL. 5415/16" CURB WFIDNT(LW.) APPROVALS DATE SOD 1-4005-7040 CURB SHOWN IS CDI STANDARD CONFIGURATION 134.71 °""" wicks' Notes: CDI RESERVES THE RIGHT TO CHANGE LAYOUT ^�� 1.1.5"ADDED TO OLD CURB O.D .."."'a Wednesday,February 09,2011 6:05:44 P QUOTE#: 2.MATERIAL 18 gga.GALVANIZED STEEL WITHOUT NOTIFICATION.IF CURB IS NEEDED INA NESIFY EXISTING CURB OD � ,. DRAWING Na: 3.GASKET PROVIDED VWTHCURB DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED NERIFY SUPPLY AND RETURN OPENINGS 'm" 17680 TYLER8TNW 'NOTE ANY CHANGES a.,.a _ CDI ELK RIVER,MN 65380 1-4005-7040 2. 4.INSULATION:1"11/2 LB DENSITY PRIOR TO PLACING AN ORDER. "CALLNATNANY QUESTIONS �` I (77113391.77110 ttOR 'FAX BACK IF DRAWING IS OK AS IS ita-1 *Fa (753)3111-711111 rxa 125 I sem, 1 or 3 m r .k A----( - . . . General Data RGEA1 6 Series NOMINAL SIZES 2-5 TONS [7.0-1Z6 kW] Model RGEA16 Series 024AJV062AA 024AJVO6TAA 036ACVO62AA 036ACVO82AA Cooling Performance' CONTINUED-t• Gross Cooling Capacity(2nd Stage)Btu[kW] 24,200[7.09] 24,200[7.09] 36,800[10.78] 36,800[10.78] SEERZ 16 16 16 16 EER(1st stage/2nd stage) 13.5/12.4 13.5/12.4 13.4/12.3 13.4/12.3 AHRI Rated CFM(1st/2nd stage)[Us] 550/800[260/378] 550/800[260/378] 800/1200[378/566] 800/1200[378/566] AHRI Net Cooling Capacity(1st/2nd stage)Btu[kW] 18,500/23,800[5.42/6.97] 18,500/23,800[5.42/6.97] 25,000/36,000[7.32/10.55] 25,000/36,000[7.32/10.55] Net Sensible Capacity(1st/2nd stage)Btu[kW] 13,380/17,410[3.92/5.1] 13,380/17,410[3.92/5.1] 18,470/27,280[5.41/7.99] 18,470/27,280[5.41/7.99] Net Latent Capacity(1st/2nd stage)Btu[kW] 5,120/6,390[1.5/1.87] 5,120/6,390[1.5/1.87] 6,530/8,720[1.91/2.55] 6,530/8,720[1.91/2.55] Net System Power(1st/2nd stage)[kW] 1.37/1.92 1.37/1.92 1.87/2.94 1.87/2.94 Heating Performance(Gas)' Heating Input Btu[kW](1st Stage/2nd Stage) 46,000/60,000[13.48/17.58) 46,000/60,000[13.48/17.58] 46,000/60,000[13.48/17.58] 61,000/80,000[17.87/23.44] Heating Output Btu[kW](1st Stage/2nd Stage) 37,567/49,000[11.01/14.36] 37,567/49,000[11.01/14.36] 37,260/48,600[10.92/14.24] 49,410/64,800[14.48/18.99] 1 Temperature Rise Range of[°C] 10-40[5.6-22.2]/ 10-40[5.6-22.2]/ 10-40[5.6-22.2]/ 15-45[8.3-25]/ (1st Stage/2nd Stage) 20-50[11.1-27.8] 20-50[11.1-27.8] 20-50[11.1-27.8] 25-55[13.9-30.6] AFUE% 81 81 0 0 Steady State Efficiency(%) 82 82 82 82 No.Burners 3 3 3 4 No.Stages 2 2 2 2 Gas Connection Pipe Size in.[mm] 0.5[12.7] 0.5[12.7] 0.5[12.7] 0.5[12.7] Compressor No/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll Outdoor Sound Rating(dB)5 76 76 76 76 Outdoor Coll-Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled MicroChannel Depth in.[mm] 0.375[9.5] 0.375[9.5] 0.375[9.5] 0.375[9.5] Face Area sq.ft.[sq.m] 10.56[0.98] 10.56[0.98] 16.23[1.51] 16.23[1.51] Rows/FPI[FPcm] 1/18[7] 1/18[7] 2/22[9] 2/22[9] Indoor Coil-Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in.[mm]OD 0.375[9.5] 0.375[9.5] 0.375[9.5] 0.375[9.5] Face Area sq.ft.[sq.m] 5.54[0.51] 5.54[0.51] 7.39[0.69] 7.39[0.69] Rows/FPI[FPcm] 2/15[6] 2/15[6] 2/15[6] 2/15[6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No/Size in.[mm] 1/0.75[19.05] 1/0.75[19.05] 1/0.75[19.05] 1/0.75[19.05] Outdoor Fan-Type Propeller Propeller Propeller Propeller No.Used/Diameter in.[mm] 1/22[558.8] 1/22[558.8] 1/22[558.8] 1/22[558.8] Drive Type/No.Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM[Us] 2500[1180] 2500[1180] 2700[1274] 2700[1274] No.Motors/HP 1 at 1/6 HP 1 at 1/6 HP 1 at 1/6 HP 1 at 1/6 HP Motor RPM 850 850 850 850 indoor Fan-Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No.Used/Diameter in.[mm] 1/10x9[254x229] 1/10x9[254x229] 1/10x9[254x229] 1/10x9[254x229] Drive Type Direct Direct Direct Direct No.Speeds Multiple Multiple Multiple Multiple No.Motors 1 1 1 1 Motor HP 1/2 1/2 1/2 3/4 Motor RPM 1050 1050 1050 1050 Motor Frame Size 48 48 48 48 Filter-Type Field Supplied Field Supplied Field Supplied Reld Supplied Furnished No No No No (NO.)Size Recommended in.[mm x mm x mm] (1)1x20x20[25x508x508] (1)1x20x20[25x508x508] (1)1x24x24[25x610x610] (1)1x24x24[25x610x610] Refrigerant Charge Oz.[g] 97.6[2767] 97.6[2767] 155.2[4400] 155.2[4400] Weights Net Weight lbs.[kg] 454[206] 454[206] 544[247] 549[249] Ship Weight lbs.[kg] 467[212] 467[212] 558[253] 558 1253] See Page 12 for Notes. [ ]Designates Metric Conversions RELY ON RUUD.TM 7