Report (82) Fs'40\U - alit, k,, C)L50 ..Q "u\ILMcI ., i' I'('.;; ',,,,i ,''}- ' iZ: VVYAT T FIRE PROTECTION, INECE`\I n ' 9095 S.W. Burnham Tigard, OR 97223 APR 04 2016 TY T9 I D N BCIUILDINGOF DIVISIO SOUTH VIEW LOT #23 12050 SW AUTUMN VIEW ST TIGARD, OR 97224 FIRE PROTECTION EQUIPMENT SUBMITTAL tilcoWorldwid Fire Pr a www.tyco-fire.com otection Contacts Products RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General proven to help in the control of residen- tial fires and to improve the chance for Description occupants to escape or be evacuated. The Series LFII Residential Flat-Plate The TYCO RAPID RESPONSE Series Concealed Pendent Sprinklers are LFII Residential Flat-Plate Concealed shipped with a Disposable Protective Pendent Sprinklers(TY2524)are decora- Cap.The Protective Cap protects the tive,fast response,fusible solder sprin- sprinkler during ceiling installation or klers designed for use in residential oc- finish.After ceiling installation is corn- ' cupancies such as homes,apartments, plete, the Protective Cap is removed dormitories,and hotels. and the Cover Plate/Retainer Assem- The Cover Plate/Retainer Assembly con- bly is installed. Removing the Protec- ceals the sprinkler operating compo- tive Cap is required for proper sprinkler nents above the ceiling.The flat profile performance. The owner is responsible for maintaining of the Cover Plate provides the optimum Dry Pipe System Application their fire protection system and devic- aesthetically appealing sprinkler design. The Series LFII Residential Flat-Plate es in proper operating condition. Con- Additionally,the concealed design of the Concealed Pendent Sprinkler offers a tact the installing contractor or sprinkler Series LFII Residential Flat-Plate Con- laboratory approved option for design- manufacturer with any questions. cealed Pendent Sprinklers provides 1/2 ing dry pipe residential sprinkler sys- inch(12,7 mm)vertical adjustment.This tems,whereas,most residential sprin- Sprinkler adjustment provides a measure of flex- klers are laboratory approved for wet ibility when cutting fixed sprinkler drops. systems only. Identification The Series LFII Residential Flat-Plate Through extensive testing,it has been Concealed Pendent Sprinklers are in- determined that the number of design Number (SIN) tended for use in the following systems: sprinklers(hydraulic design area)for the •wet and dry pipe residential sprin- Series LFII Residential Flat-Plate Con- TY2524 kler systems for one- and two-fam- cealed Sprinklers(TY2524)need not be ily dwellings and mobile homes per increased over the number of design NFPA 13D sprinklers(hydraulic design area)speci- •wet and dry pipe residential sprin- fied for wet pipe sprinkler systems, as kler systems for residential occu- is customary for density/area sprinkler pancies up to and including four sto- systems designed per NFPA 13, 13D, ries in height per NFPA 13R or 13R. •wet and dry pipe sprinkler systems Consequently,the Series LFII Residen- for the residential portions of any tial Flat Plate Concealed Sprinklers occupancy per NFPA 13 (TY2524)offer the features of non-wa- ter filled pipe in addition to not having to The Series LFII Residential Sprinklers increase the number of design sprinklers have been designed with heat sensitiv- (hydraulic design area)for systems de- ity and water distribution characteristics signed to NFPA 13, 13D,or 13R. NOTICE The Series LFII Residential Rat-Plate IMPORTANT Concealed Pendent Sprinklers(TY2524) Always refer to Technical Data described herein must be installed and Sheet TFP700 for the "INSTALLER maintained in compliance with this doc- WARNING"that provides cautions ument and the applicable standards of with respect to handling and instal- the National Fire Protection Association, lation of sprinkler systems and com- in addition to the standards of any au- ponents.Improper handling and in- thorities having jurisdiction. Failure to stallation can permanently damage do so may impair the performance of a sprinkler system or its compo- these devices. nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 FEBRUARY 2014 TFP443 TFP443 Page 2 of 6 BODY , SEALING WRENCH (1/2"NPT) , #- ASSEMBLY RECESS CAP r-----------------=------------.0, � ��`;j�A SPRINKLER ,\4-1 `\■�! , WRA EAING SADDLE I) I ` PUSH WRENCH SUPPORT O 11 1 $ SCREW COMPRESSIONINTO ENSURE CUP WITH ) ENGAGEMENT ROLL FORMED t WITH SPRINKLER THREADS N \ � , WRENCHING AREA ` = LEVER FIGURE 2 R 1.111 W-TYPE 18 GUIDEyL__. SPRINKLER WRENCH PIN ,' „ 'J, ' ' SOLDER LINK ELEMENT GUIDE PIN HOUSING _ DEFLECTOR ' OPERATED DEFLECTOR I E 1___s- (POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO I I RETAINER SUPPORT I WITH THREAD CUP UNTIL J I DIMPLES MOUNTING \ O O I� SURFACE IS J FLUSH WITH CEILING EJECTION SPRING SOLDER J COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) 2-1/2"DIA. SPRINKLER- (63,5 mm) 1/2"(12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT FITTING OPERATED imaiilk �� SPRINKLER I1 1, _ COVER 1-7/8"±1/4" - PLATE I (47,6 mm > �� = I I I 1/8"GAP ±6,4 mm) RETAINER� _ (3,2 mm) — 1ii COVER SPRINKLER 7/8" (22,2 mm) lilt RETAINER SUPPORT CUP (28,6 mm 3/16" j MOUNTING SURFACE 1-1/8" ) ASSEMBLY ASSEMBLY \ �_� (4,8 mm) 3-3/16"DIA. _ DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE(TY2524) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP443 Page 3 of 6 Technical Design Criteria Dry Pipe System Water Delivery When using the Series LFII Residential Data The TYCO RAPID RESPONSE Series Flat-Plate Concealed Pendent Sprinklers LFII Residential Flat-Plate Concealed (TY2524)in dry pipe sprinkler systems, Approvals Pendent Sprinklers (TY2524) are UL the time for water delivery must not ex- UL and C-UL Listed and C-UL Listed for installation in ac- ceed 15 seconds for the most remote The TYCO RAPID RESPONSE Series cordance with this section: operating sprinkler. LFII Residential Flat-Plate Concealed Residential Sprinkler Design Guide Obstruction to Water Distribution Pendent Sprinklers are only listed with When conditions exist that are outside Sprinklers are to be located in accor- the Series LFII Concealed Cover Plates the scope of the provided criteria, re- dance with the obstruction rules of having a factory-applied finish. fer to the Residential Sprinkler Design NFPA 13D, 13R,and 13 as applicable These Cover Plates and their part num- Guide TFP490 for the manufacturer's for residential sprinklers as well as with bers can be found in the Ordering Pro- recommendations that may be accept the obstruction criteria described within cedure section at the end of this data able to the authority having jurisdiction. the Technical Data Sheet TFP490. sheet. System Type Operational Sensitivity For details on approvals,refer to the De- Per the UL Listing,wet pipe and dry pipe Install sprinklers relative to the ceiling sign Criteria section. systems may be utilized.Per the C-UL mounting surface as shown in Figure 3. Listing,only wet pipe systems may be The Series LFII Residential Flat-Plate Maximum Working Pressure utilized. Concealed Pendent Sprinklers must 175 psi(12,1 bar) Refer to Technical Data Sheet TFP485 not be used in applications where the Discharge Coefficient about the use of Residential Sprinklers air pressure above the ceiling is greater K=4.9 GPM/psi'"2(70,6 LPM/bar'12) in residential dry pipe systems. than that below. Down drafts through the Support Cup can delay sprinkler op- Temperature Rating Ceiling Types eration in a fire situation. Sprinkler: 160°F(71°C) Smooth flat horizontal, or beamed, or Cover Plate: 139°F(59°C) sloped, in accordance with the 2013 Sprinkler Spacing Edition of NFPA 13D, 13R or 13 as The minimum spacing between sprin- Vertical Adjustment applicable. klers is 8 feet (2,4 m). The maximum 1/2 inch (12,7 mm) spacing between sprinklers cannot ex- Hydraulic Design ceed the length of the coverage area Finishes (NFPA 13D and 13R) (Table A)being hydraulically calculated Refer to the Ordering Procedure section. For systems designed to NFPA 13D or (e.g.,a maximum of 12 feet for a 12 ft.x Physical Characteristics NFPA 13R,the minimum required sprin- 12 ft.coverage area or 20 feet for a 20 Cover Plate/Retainer Assembly: kler flow rate are given in Tables A and ft.x 20 ft.coverage area.) Cover Plate Copper B as a function of temperature rating Ejection Spring Stainless Steel and the maximum allowable coverage Retainer Brass areas.The sprinkler flow rate is the mini- Sprinkler/Support Cup Assembly: mum required discharge from each of Body Brass the total number of"design sprinklers" Cap Bronze as specified in NFPA 13D or NFPA 13R. Saddle Brass The number of"design sprinklers"spec- Sealing Assembly Beryllium ified in NFPA 13D and 13R for wet pipe Nickel w/TEFLON systems is to be applied when designing Soldered Link Halves Nickel dry pipe systems. Lever Bronze Compression Screw Brass Hydraulic Design Deflector Bronze (NFPA 13) Guide Pin Housing Bronze For systems designed to NFPA 13,the Guide Pins Bronze number of design sprinklers is to be Support Cup Steel the four most hydraulically demanding Operation sprinklers.The minimum required dis- charge from each of the four sprinklers When exposed to heat from a fire, the is to be the greater of the following: Cover Plate,which is normally soldered •The flow rates given in Tables A and to the Retainer at three points,falls away B as a function of temperature rating to expose the Sprinkler/Support Cup As- and the maximum allowable cover- sembly.At this point,the Deflector,sup- age area ported by the Guide Pins, drops down •A minimum discharge of 0.1 gpm/ft2. to its operated position. over the"design area" comprised of The Solder Link Element of the Sprinkler/ the four most hydraulically demand- Support Cup Assembly is comprised of ing sprinklers for the actual coverage two link halves that are soldered togeth areas being protected by the four er with a thin layer of solder.When the sprinklers rated temperature is reached,the sol- The number of "design sprinklers" der melts and the two link halves sepa- specified in NFPA 13 for wet pipe sys- rate, allowing the sprinkler to activate tems is to be applied when designing and flow water. dry pipe systems. TFP443 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressureebe°) Maximum Maximum Coverage Area 0) Spacing Ordinary 160°F( 7 TempRating Ft.x Ft. Ft. Deflector to Installation Minimum (m x m) (m) Flow Pressure Ceiling Type Spacing GPM PSI (L/min) (bar) (m) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to - 14 x 14 14 13 7.0 1-1/8 inches. (4,3 x 4,3) (4,3) 49,2) (0,48) Beamed 16 x 16 16 13 7.0 Ceilings perNFPA 13D Concealed 8 (4,9 x 4,9) (4,9) (49,2) (0,48) 13R,or 13 (2,4) 18 x 18 18 17 12.0 Installed in (5,5 x 5,5) (5,5) (64,3) (0,83) beam 7/8 to 1-1/8 inches 20 x 20 20 20 16.7 below bottom (6,1 x 6,1) (6,1) (75,7) (1,15) of beam (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pres- sums are calculated using the nominal K-factor.Refer to"Hydraulic Design"in the Design Criteria section for details. (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Maximum Minimum Flow and Residual Pressure) Coverage Spacing Ordinary Temp Rating �a Area Ft. 160°F(71°C) Ft.x Ft. Deflector to Installation Minimum (m x m) (m) Flow Pressure Ceiling Type Spacing GPM PSI Ft. (L/min) (bar) (m) 12 x 12 12 15 9.4 Smooth (3,7 x 3,7) (3,7) (56,8) (0,65) Ceilings 7/8 to 14 x 14 14 15 9.4 1-1/8 inches. (4,3 x 4,3) (4,3) (56,8) (0,65) Beamed 16 x 16 16 16 10,7 Ceilings per 8 (4,9 x 4,9) (4,9) (60,6) (0,74) NFPA 13D Concealed (2 4) 13R,or 13 18 x 18 18 17 12.0 Installed in (5,5 x 5,5) (5,5) (64,3) (0,83) beam 7/8 to 1-1/8 inches 20 x 20 20 21 18,4 below bottom (6,1 x 6,1) (6,1) (79,5) (1,27) of beam (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to"Hydraulic Design"in the Design Criteria section for details. (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP443 Page 5 of 6 Installation Step 6.Screw on the Cover Plate/Re- Automatic sprinklers must never be tamer Assembly until its flange contacts painted,plated,coated,or otherwise The TYCO RAPID RESPONSE Series the ceiling. Do not continue to screw altered after leaving the factory.Modi LFII Residential Flat-Plate Concealed on the Cover Plate/Retainer Assembly fied or overheated sprinklers must be Pendent Sprinklers must be installed in such that it lifts a ceiling panel out of replaced. accordance with this section: its normal position. If the Cover Plate/Retainer AssemblyCare must be exercised to avoid dam- General Instructions cannot be en a ed with the age to the sprinklers-before,during, dam- Damage to the Solder Link Element dur- g 9 Mounting and after installation.Sprinklers dam- gCup or the Cover Plate/Retainer Assem- aged bydropping, ing installation can be avoided by han- blycannot be en aged sufficientlyto pp striking,wrench twist/ dling the sprinkler by the Support Cu g g slippage,or the like,must be replaced. Cup contact the ceiling,the Sprinkler Fitting only;that is,do not apply pressure to the must be repositioned. The owner is responsible for the in- Solder Link Element(Figure 1). spection,testing,and maintenance of A leak tight 1/2 inch NPT sprinkler joint Care and their fire protection system and devices should be obtained by applying a min in compliance with this document,as imum-to-maximum torque of 7 to 14 well as with the applicable standards of ft.-lbs. (9,5 to 19,0 Nm). Higher levels Maintenance the National Fire Protection Association stan- of torque can distort the sprinkler inlet The TYCO RAPID RESPONSE Series (e.g., NFPA 25),in addition to the ju- with consequent leakage or impairment LFII Residential Flat-Plate Concealed risdards of any othert the installing having of the sprinkler. Pendent Sprinkler(TY2524) must be for or sprion.inkler kler m er r gardincontra - maintained and serviced in accordance for q estions.manufacturer regarding Do not attempt to compensate for insuf- any questions. ficient adjustment in the Cover Plate/ with the section: rec- Retainer Assembly by under-or over- Before closing a fire protection system Automatic sprinkler systems are tightening the sprinkler. Re adjust the main control valve for maintenance work o and maintained aim d to be inspected, tested, position of the sprinkler fitting to suit. on the fire protection system that it con- n Service in ccby a qualified withInlocal trots,obtain tion Service in accordance local Step 1. Install pendent sprinklers in permission to shut down the requirements and/or national codes. the pendent position,with the center- affected fire protection system from the line of the sprinkler perpendicular to the proper authorities and notify all person- mounting surface. nel who may be affected by this action. Step 2. Remove the Protective Cap. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. Step 3.With pipe-thread sealant ap- plied to the pipe threads,and using the The owner must assure that the sprin- W-Type 18 Wrench shown in Figure 2, klers are not used for hanging any ob- install and tighten the Sprinkler/Sup- jects and that the sprinklers are only port Cup Assembly into the fitting.The cleaned by means of gently dusting with : -. W-Type 18 Wrench accepts a 1/2 inch a feather duster;otherwise,non-opera- ratchet drive. tion in the event of a fire or inadvertent Step 4. Replace the Protective Cap by operation may result. pushing it upwards until it bottoms out When properly installed,there is a nomi- against the Support Cup.The Protec- nal 1/8 inch(3,2 mm)air gap between tive Cap helps prevent damage to the the lip of the Cover Plate and the ceil- Deflector and Guide Pins during ceiling ing,as shown in Figure 3.This air gap installation and/or during application of is necessary for proper operation of the the finish coating of the ceiling. sprinkler by allowing heat flow from a fire to pass below and above the Cover NOTICE Plate to help assure appropriate release of the Cover Plate in a fire situation.If the As long as the protective Cap remains ceiling needs repainting after sprinkler in place,the system is considered"Out installation,exercise care to ensure that Of Service". the new paint does not seal off any of Step 5.After the ceiling has been corn- the air gap.Failure to do so may impair pleted with the 2-1/2 inch(63 mm)diam- sprinkler operation. eter hole and in preparation for install- Factory painted Cover Plates must not ing the Cover Plate/Retainer Assembly, be repainted.They should be replaced, remove and discard the Protective Cap, if necessary, by factory painted units. and verify that the Deflector moves up Non-factory applied paint may adversely and down freely. delay or prevent sprinkler operation in If the sprinkler has been damaged and the event of a fire. the deflector does not move up and Do not pull the Cover Plate relative to the down freely,replace the entire sprinkler Retainer.Separation may result. assembly. Do not attempt to modify or repair a damaged sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. TFP443 Page 6 of 6 Limited Warranty For warranty terms and conditions,visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability.When placing an order, indicate the full product description and Part Number(P/N). Sprinkler/Support Cup Assembly Specify:Series LFII(TY2524), K-4.9 (70,6),Residential Flat-Plate Concealed Pendent Sprinkler without Cover Plate/ Retainer Assembly,P/N 51-114-1-160 Cover Plate/Retainer Assembly Specify:Series LFII(TY2524), K=4.9 (70,6),Residential Flat-Plate Concealed Pendent Sprinkler Cover Plate/Retain- er Assembly with(specify)finish, P/N (specify): Ivory(RAL 1015) P/N 56-202-0-135 Beige(RAL 1001) P/N 56-202-2-135 Pure White(b)(RAL 9010) P/N 56-202-3-135 Signal White(a)(RAL 9003) P/N 56-202-4-135 Grey White(RAL 9002) P/N 56-202-5-135 Brown(RAL 8028) P/N 56-202-6-135 Black(RAL 9005) P/N 56-202-7-135 Brushed Brass P/N 56-202-8-135 Brushed Chrome P/N 56-202-9-135 Custom Paint P/N 56-202-X-135 (a)Previously known as Bright White. (b)Eastern Hemisphere sales only. Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t"co TEFLON is trademark of The DuPont Corporation. Fire Protection Products Page 2 of 6 TFP1915 NOMINAL AVERAGE AVERAGE WEIGHT WATER FILLED WEIGHT FT.OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. lbs./ft. lbs./ft. PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 FIGURE 1—PIPE DIMENSIONS Installation Care and Tyco Fire and Building Products Maintenance (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- The owner is responsible for the fin- ance with IH-1900, Rev. 0, January spection, testing, and maintenance of 2005"Installation Instruction&Techni- their fire protection system and de- cal Handbook". vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls,permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. - After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (TIO) SCHD. (lb.) TEE 80000 3/4" 5/8" 40 0.11 ,mm, - TIO 80001 11/16" 40 0.19 �J• j-_ 80002 1-1/4" 7/8" 40 0.26 iiM 80003 1-1/2" 1-1/16" 80 0.51 .JMIN- 80004 2" 1-3/8" 80 0.90 T/O ■■ T/O 80005 2-1/2" 1-9/16" 80 1.59 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 80132 3/4"x 3/4"x 1" 3/4" 3/4" 5/8" 40 0.14 80133 1"x 3/4"x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1"x 3/4"x 1" 3/4" 11/16" 3/4" 40 0.17 80260 1"x 1"x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4"x 1"x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4"x 1"x 1" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4"x 1"x 1-1/4" 15/16" 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4"x 1-1/4"x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4"x 1-1/4"x 1" 3/4" 3/4" 7/8" 40 0.26 2 80138 1-1/4"x 1-1/4"x 1-1/2" 1" 1" 1" 80 0.43 0..1 T/O 0 I 80140 1-1/2"x 1-1/4"x 3/4" 9/16" 9/16" 1" 80 0.36 ,.0E80141 1-1/2"x 1-1/4"x 1" 9/16" 9/16" 1-1/16" 80 0.38 �WM 80263 1-1/2"x 1-1/2"x 3/4" 9/16" 9/16" 1" 80 0.36 X Mill11.Y I 80264 1-1/2"x 1-1/2"x 1" 9/16" 9/16" 1-1/16" 80 0.38 -, or- 11111 ' 80275 1-1/2"x 1-1/2"x 1-1/4" 7/8" 7/8" 1" 80 0.45 TIO 11111T/O 80265 2"x 2"x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2"x 2"x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2"x 2"x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74 80267 2"x 2"x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2"x 2-1/2"x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2"x 2-1/2"x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2"x 2-1/2"x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-1/2"x 2-1/2"x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3"x 3"x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3"x 3"x 2" 1-13/16" 1-13/16" 1-3/4" 80 2.25 80269 3"x 3"x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44 CROSS&REDUCING CROSS 80009 3/4" 9/16" 40 0.13 80010 1" 11/16" 40 0.23 J4.. __ T/O 80011 1-1/4" 15/16" 40 0.34 IM-41111111.• 80012 1-1/2" 1-1/16" 80 0.67 .ME -M 80013 2" 1-5/16" 80 1.00 l_...1r____. 80014 2-1/2" 1-9/16" 80 1.91 Ilmmtl T/O 80008 3" 1-13/16" 80 2.89 T/O •■ T/O 80015 1"x 1"x 3/4"x 3/4" 7/8" 40 0.28 90°ELBOW& 80025 3/4" 5/8" 40 0.09 80026 1" 3/4" 40 0.14 REDUCING ELBOW 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 ;Emil TIO 80029 2" 1-5/16" 80 0.79 j 80030 2-1/2" 1-9/16" 80 1.14 Tice Y 80031 3" 1-13/16" 80 1.82 VP= X x Y X Y - -T/O 80032 1"x 3/4" 11/16" 13/16" 40 0.16 FIGURE 2-FITTING DIMENSIONS(Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (TIO) SCHD. (lb.) 45°ELBOW 80050 3/4" 3/8" 40 0.08 T/0 80051 1" 3/8" 40 0.11 80052 1-1/4" 3/4" 40 0.20 4"' 80053 1-1/2" 1/2" 80 0.31 T/O\ S = 80054 2" 3/4" 80 0.56 4iA= 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING& 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 I 80078 1-1/2" 3/16" 80 0.25 80079 2" 3/16" 80 0.38 80080 2-1/2" 1/4" 80 0.67 O 80081 3" 3/16" 80 0.91 80220 1"x 3/4" 1/8" 40 0.08 80200 1"x 3/4" 7/16" 40 0.04 80201 1-1/4"x 3/4" 1/2" 40 0.11 80202 1-1/4"x 1" 5/16" 40 0.12 80203 1-1/2"x 3/4" 5/8" 80 0.16 80204 1-1/2"x 1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2"x 1-1/4" 3/8" 80 0.17 7 80206 2"x 3/4" 13/16" 80 0.27 80207 2"x 1" 11/16" 80 0.26 80208 2"x 1-1/4" 9/16" 80 0.24 ',r%L 80209 2"x 1-1/2" 7/16" 80 0.19 -I I-T/0 80215 2-1/2"x 1" 15/16" 80 0.42 80214 2-1/2"x 1-1/4" 13/16" 80 0.45 80213 2-1/2"x 1-1/2" 11/16" 80 0.46 80211 2-1/2"x 2" 5/8" 80 0.29 80210 3"x 2" 3/4" 80 0.72 80212 3"x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 80102 1-1/4" 7/16" 40 0.10 80103 1-1/2" 11/16" 80 0.20 K,,I 80104 2" 5/8" 80 0.31 T/O-i 80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER 80160 1-1/4"x 1-1/4"Groove 2-5/16" 1-1/4"(1.660") 40 0.78 I 80161 1-1/2"x 1-1/2"Groove 2-5/16" 1-1/2"(1.900") 80 0.95 PIPE 80162 2"x 2"Groove 2-5/16" 2"(2.375") 80 1.42 O.D. 80163 2-1/2"x 2-1/2"Groove 2-5/16" 2-1/2"(2.875") 80 2.28 80164 3"x 3"Groove 2-1/4" 3"(3.500") 80 3.00 -T/O-I 80169 2-1/2"x 76,1 mm Groove 2-5/16" 76,1 mm(3.000") 80 2.28 FIGURE 2-FITTING DIMENSIONS(Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (T/O) (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4"x 1/2"NPT 7/16" 80 0.20 80176E 1"x 1/2"NPT 7/16" 80 0.22 o...,„, 80175WL 3/4"x 1/2"NPT 7/16" 40 0.16 ,,, 80179 1"x 3/4"NPT 13/16" 40 0.43 T/O SPRINKLER HEAD ADAPTER tic. 80175W 3/4"x 1/2"NPT 1/2" 40 0.19 80176W 1"x 1/2"NPT 1/2" 40 0.18 ,, >y — T/O SPRINKLER HEAD ADAPTER(SPIGOT) ...........,,A.1.: 80177L 3/4"x 1/2"NPT 1/2" 40 0.16 MG80178 1"x 1/2"NPT 9/16" 40 0.20 �-" 80180 1"x 3/4"NPT 7/8" 40 0.40 —I T/O FEMALE ADAPTER '"'7 80142 3/4"x 3/4"NPT 13/16" 40 0.41 I 80145 1'x 1"NPT 7/8" 40 0.63 80146 1-1/4"x 1-1/4"NPT 1-1/8" 40 1.03 ilii \\\\ 80147 1-1/2"x 1-1/2"NPT 1-3/8" 80 1.42 80148 2"x 2"NPT 1-11/16" 80 2.66 — —T/O MALE ADAPTER � I� VVVV � 80157 3/4"x 3/4"NPT 1-5/16" 40 40 0.33 80158 1'x 1"NPT 1-3/8" 0.56 T/O XxYxZ X Y Z SPRINKLER HEAD 80250 3/4"x 3/4"x 1/2"NPT 9/16" 9/16" 1" 40 0.22 ADAPTER TEE Z 80251 1"x 1"x 1/2"NPT 11/16" 11/16" 1-3/16" 40 0.29 ;_=`I T/O 80249 1"x 1"x 1"NPT 15/16" 15/16" 1-9/16" 40 0.73 Ik= 80256 1-1/4"x 1"x 1/2"NPT 7/16" 9/16" 1-5/16" 40 0.30 -.111 80252 1-1/4"x 1-1/4"x 1/2"NPT 7/16" 7/16" 1-5/16" 40 0.31 X EMU=Y 80257 1-1/2"x 1-1/4"x 1/2"NPT 1/2" 11/16" 1-7/16" 80 0.43 ......"ww.m. 80254 1-1/2"x 1-1/2"x 1/2"NPT 1/2" 1/2" 1-7/16" 80 0.46 T/O •• T/O 80258 2"x 1-1/2"x 1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2"x 2"x 1/2"NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2—FITTING DIMENSIONS(Part 3 of 4) Page 6 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (TIO) SCHD. (lb.) BACK-TO-BACK TEE X x Y x Z X y Z X 7 7 T/O 7 7 I Y'. muje . 80459 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.48 y`` Z I 80460 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 T/O TIO BACK-TO-BACK CROSS X x Y x Z x W X,Y Z,W • X SII T/O I IIIIIIM'IaMM lillrM`.�111 w 80462 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 —" f� 80463 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.47 TIO all T/0 T/0 SPRINKLER HEAD X x Y X Y ADAPTER 90°ELBOW Y �"`� T/O l �al I 80199 3/4"x 1/2"NPT 9/16" 1" 40 0.20 0 ' IM 80198 1"x 1/2"NPT 3/4" 1-1/4" 40 0.26 *A-X I 80196 1"x 3/4"NPT 1-1/16" 1-7/16" 40 0.26 r - -T/O FIGURE 2—FITTING DIMENSIONS(Part 4 of 4) Limited by TFBP to be defective shall be either of merchantability and fitness for a par- repaired or replaced, at TFBP's sole ticular purpose. Warranty option. TFBP neither assumes, nor authorizes any person to assume for it, This limited warranty sets forth the ex- clusive remedy for claims based on Products manufactured b T Fire& any other obligation in connection with failure of or defect in products, materi- Y Y co the sale of products or parts of prod- Building Products (TFBP) are war- ucts.TFBP shall not be responsible for als or components, whether the claim ranted solely to the original Buyer for sprinkler system design errors or inac- is made in contract, tort, strict liability ten(10)years against defects in mate- curate or incomplete information sup- or any other legal theory. rial and workmanship when paid for plied by Buyer or Buyer's repre- This warranty will apply to the full ex- • and properly installed and maintained sentatives. tent permitted by law.The invalidity, in under normal use and service. This In no event shall TFBP be liable, in whole or part, of any portion of this warranty will expire ten (10) years warranty will not affect the remainder. from date of shipment by TFBP. No contract, tort, strict liability or under • warranty is given for products or com- any other legal theory, for incidental, ponents manufactured by companies indirect,special or consequential dam- not affiliated by ownership with TFBP ages, including but not limited to labor or for products and components which charges, regardless of whether TFBP have been subject to misuse,improper was informed about the possibility of installation, corrosion, or which have such damages, and in no event shall not been installed, maintained, modi- TFBP's liability exceed an amount fied or repaired in accordance with ap- equal to the sales price. plicable Standards of the National Fire The foregoing warranty is made in lieu Protection Association, and/or the of any and all other warranties. ex- standards of any other Authorities press or implied. including warranties Having Jurisdiction. Materials found TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale,Pennsylvania 19446 Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FT.OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. lbs./ft. FILLED WEIGHT lbs./ft. PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 FIGURE 1—PIPE DIMENSIONS Installation Care and Tyco Fire and Building Products Maintenance (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- The owner is responsible for the fin- ance with IH-1900, Rev. 0, January spection, testing, and maintenance of 2005"Installation Instruction&Techni- their fire protection system and de- cal Handbook". vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls,permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible formoni- toring proprietary and/or central sta- tion alarms. TFP1915 Page 3 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (T/O) SCHD. (lb.) TEE 80000 3/4" 5/8" 40 0.11 / / T/O 80001 1" 11/16" 40 0.19 11101-- ,1. 7/8" 80003 1-1/2" 1-1/16" 80 0.51 -J1. - 80004 2" 1-3/8" 80 0.90 T/O ■■ T/O 80005 2-1/2" 1-9/16" 80 1.59 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 80132 3/4"x 3/4"x 1" 3/4" 3/4" 5/8" 40 0.14 80133 1"x 3/4"x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1"x 3/4"x 1" 3/4" 11/16" 3/4" 40 0.17 80260 1"x 1"x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4"x 1"x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4"x 1"x 1" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4"x 1"x 1-1/4" 15/16" 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4"x 1-1/4"x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4"x 1-1/4"x 1" 3/4" 3/4" 7/8" 40 0.26 Z 80138 1-1/4"x 1-1/4"x 1-1/2" 1" 1" 1" 80 0.43 T/0 80140 1-1/2"x 1-1/4"x 3/4" 9/16" 9/16" 1" 80 0.36 Ji Page 4 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (T/0) SCHD. (lb.) 45°ELBOW 80050 3/4" 3/8" 40 0.08 T/0 80051 1" 3/8" 40 0.11 80052 1-1/4" 3/4" 40 0.20 ''�!' 80053 1-1/2" 1/2" 80 0.31 T/0 ♦�1. 80054 2" 3/4" 80 0.56 'p�i�� 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING& 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 ' Y''1'' 80078 1-1/2" 3/16" 80 0.25 80079 2" 3/16" 80 0.38 rrrr 80080 2-1/2" 1/4" 80 0.67 -I-T/O 80081 3" 3/16" 80 0.91 80220 1"x 3/4" 1/8" 40 0.08 80200 1"x 3/4" 7/16" 40 0.04 80201 1-1/4"x 3/4" 1/2" 40 0.11 80202 1-1/4"x 1" 5/16" 40 0.12 80203 1-1/2"x 3/4" 5/8" 80 0.16 80204 1-1/2"x 1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2"x 1-1/4" 3/8" 80 0.17 80206 2"x 3/4" 13/16" 80 0.27 _.,/i 80207 2"x 1" 11/16" 80 0.26 80208 2"x 1-1/4" 9/16" 80 0.24 'T ,,[, 80209 2"x 1-1/2" 7/16" 80 0.19 F-T/0 80215 2-1/2"x 1" 15/16" 80 0.42 80214 2-1/2"x 1-1/4" 13/16" 80 0.45 80213 2-1/2"x 1-1/2" 11/16" 80 0.46 80211 2-1/2"x 2" 5/8" 80 0.29 80210 3"x 2" 3/4" 80 0.72 80212 3"x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" 40 0.06 1,, 80102 1-1/4" 7/16" 40 0.10 80103 1-1/2" 11/16" 80 0.20 141_ 80104 2" 5/8" 80 0.31 1/0-I80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED TIO PIPE O.D. COUPLING ADAPTER 80160 1-1/4"x 1-1/4"Groove 2-5/16" 1-1/4"(1.660") 40 0.78 I 80161 1-1/2"x 1-1/2"Groove 2-5/16" 1-1/2"(1.900") 80 0.95 PIPE 80162 2"x 2"Groove 2-5/16" 2"(2.375") 80 1.42 O.D. :,- -"N.�� 80163 2-1/2"x 2-1/2"Groove 2-5/16" 2-1/2"(2.875") 80 2.28 80164 3"x 3"Groove 2-1/4" 3"(3.500") 80 3.00 -T/0-I 80169 2-1/2"x76,1 mm Groove 2-5/16" 76,1 mm(3.000") 80 2.28 FIGURE 2-FITTING DIMENSIONS(Part 2 of 4) TFP1915 Page 5 of 6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (T/O) SCHD. (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4"x 1/2"NPT 7/16" 80 0.20 80176E 1"x 1/2"NPT 7/16" 80 0.22 h"" 80175WL 3/4"x 1/2"NPT 7/16" 40 0.16 80179 1"x 3/4"NPT 13/16" 40 0.43 T/O - SPRINKLER HEAD ADAPTER , 80175W 3/4"x1/2"NPT 1/2" 40 0.19 80176W 1"x 1/2"NPT 1/2" 40 0.18 — T/O SPRINKLER HEAD ADAPTER(SPIGOT) " _ 80177L 3/4x 1/2"NPT �. 1/2" 40 0.16 MN80178 1"x 1/2"NPT 9/16" 40 0.20 1I 80180 1"x 3/4"NPT 7/8" 40 0.40 —I T/O FEMALE ADAPTER '//// 4k, 80142 3/4"x 3/4"NPT 13/16" 40 0.41 Is x 80145 80146 1'x 1"NPT 7/8" 40 0.63 1-1/4"x 1-1/4"NPT 1-1/8" 40 1.03 \\\\ 80147 1-1/2"x 1-1/2"NPT 1-3/8" 80 1.42 /zr� 80148 2"x2"NPT 1-11/16" 80 2.66 — —T/O MALE ADAPTER iii/ — [ _.--J---_ 80157 3/4"x 3/4"NPT 1-5/16" 40 0.33 80158 1'x 1"NPT 1-3/8" 40 0.56 T/O— XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4"x 3/4"x 1/2"NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1"x 1"x 1/2"NPT 11/16" 11/16" 1-3/16" 40 0.29 I;_=% T/O 80249 1"x 1"x 1"NPT 15/16" 15/16" 1-9/16" 40 0.73 k—mkt �- 80256 1-1/4"x 1"x 1/2"NPT 7/16" 9/16" 1-5/16" 40 0.30 1114 -II- 80252 1-1/4"x 1-1/4"x 1/2"NPT 7/16" 7/16" 1-5/16" 40 0.31 X -NI- Y 80257 1-1/2"x 1-1/4"x 1/2"NPT 1/2" 11/16" 1-7/16" 80 0.43 '. III 80254 1-1/2"x 1-1/2"x 1/2"NPT 1/2" 1/2" 1-7/16" 80 0.46 T/O •• T/O 80258 2"x 1-1/2"x 1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2"x 2"x 1/2"NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2—FITTING DIMENSIONS(Part 3 of 4) Page 6 of 6 TFP1915 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT WEIGHT TYPE NUMBER (TIO) SCHD. (lb.) BACK-TO-BACK TEE X x Y x Z X y Z X e T/0 i e i y'.4 ex.:- 80459 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.48 a`` Z( 80460 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 • T/O T/O BACK-TO-BACK CROSS X x Y x Z x W X,Y Z,W • X III T/O uuummfalulul 111111JA� 1111 w 80462 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 — f - 80463 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.47 T/O II T/0 T/0 SPRINKLER HEAD X x Y X Y ADAPTER 90°ELBOW Y ; ' `l TIO Is h I 80199 3/4"x 1/2"NPT 9/16" 1" 40 0.20 - 80198 1"x 1/2"NPT 3/4" 1-1/4" 40 0.26 sim-x 1 80196 1"x 3/4"NPT 1-1/16" 1-7/16" 40 0.26 — —T/O FIGURE 2—FITTING DIMENSIONS(Part 4 of 4) Limited by TFBP to be defective shall be either of merchantability and fitness for a par- repaired or replaced, at TFBP's sole ticular.purpose. Warranty option. TFBP neither assumes, nor authorizes any person to assume for it, This limited warranty sets forth the ex- clusive remedy for claims based on Products manufactured b T Fire& any other obligation in connection with failure of or defect in products, materi- Y Y co the sale of products or parts of prod- Building Products (TFBP) are war- ucts.TFBP shall not be responsible for als or components, whether the claim ranted solely to the original Buyer for sprinkler system design errors or inac is made in contract, tort, strict liability ten(10)years against defects in mate- curate or incomplete information sup- or any other legal theory. rial and workmanship when paid for plied by Buyer or Buyer's repre- This warranty will apply to the full ex- • and properly installed and maintained sentatives. tent permitted by law.The invalidity, in under normal use and service. This whole or part, of any portion of this warranty will expire ten (10) years In no event shall TFBP be liable, in warranty will not affect the remainder. from date of shipment by TFBP. No contract, tort, strict liability or under warranty is given for products or com- any other legal theory, for incidental, ponents manufactured by companies indirect,special or consequential dam- not affiliated by ownership with TFBP ages, including but not limited to labor or for products and components which charges, regardless of whether TFBP have been subject to misuse,improper was informed about the possibility of installation; corrosion, or which have such damages, and in no event shall not been installed, maintained, modi- TFBP's liability exceed an amount fied or repaired in accordance with ap- equal to the sales price. plicable Standards of the National Fire The foregoing warranty is made in lieu Protection Association, and/or the of any and all other warranties. ex- standards of any other Authorities press or implied. including warranties Having Jurisdiction. Materials found TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Dimensions - Weights A r . • 0 /\ III 1M111":‘,...71 lit* F '�kri/ I Suffix HC - Fire Hydrant Fittings dimension"A"=231/2"(594mm) *-H -4-1-4. 4 G SIZE(ON) DIMENSIONS WEIGHT A B C F G H I • in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 1/2 15 10 254 4% 117 27A6 62 5 127 33/4 85 25/6 59 21/6 52 4.5 2 • 3/4 20 111/2 282 4 102 3% 79 63/6 157 32/6 87 21/2 54 15/6 33 5 2.3 1 25 131 337 5% 130 4 102 712 191 33/4 85 111/6 43 111/16 43 12 5.4 114 32 16% 416 5 127 35/6 84 912 241 5 127 3 76 2 50 15 6.8 11/2 40 16% 425 4'/8 124 312 89 9% 248 513/6 148 3% 79 2% 68 15.86 7.2 2 50 191/2 495 6/ 159 4 102 13% 340 6% 156 37A6 87 211/6 68 25.75 11.7 Strainer sold separately Capacities kPa psi 11/4" (32mm) As compiled from documented Foundation for Cross-Connection Control 96 14 and Hydraulic Research at the University of Southern California lab tests. w 83 12 ATypical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) o 69 10 kPa psi f/2" (15mm) 8 55 2 83 12 A 41 6 e, 28 4 Iss a1a 2 .10 41 6� - 0 0 w 28 4 " 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm w 14 2 °P 0 38 76 114 152 190 228 266 304 342 380 418 456 1pm d 0 0 5 7.5 10 15 fps 0 2 4 6 8 10 12 gpm 1.5 2.3 3.0 4.6 mps °P 0 7.6 15.2 22.8 30.4 38 45.6 Ipm Flow Rate s 1.5 2.3 3.0 mps kPa psi 11/2" (40mm) Flow Rate 83 12 kPa psiA 3/4" (20mm) 2 6� 10 is 152 22 O 55 8 is o 124 18 i 41 6 N O 28 4 0 96 14 2 14 2 2 69 10 E 0 0 a 41 6 a °PO 38 76 114 O 10 20 30 1 2 190 228 266 304 342 380 418 50 60 70 80 90 100 110 1456 pm20 m 14 2 5 7.5 10 15 fps 0 5 10 15 2A 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps °P 0 19 33 9 M 95 114 133 152 171 1E0Ipm Flow Rate 7.5 15 fps 2.3 4.6 mps kPa psi 2"(50mm) Flow Rate ,a 83 12 A 2 110Pa 6 A 1 1" (25mm) o 69 10 J 55 8 083 12 i 69 10 7 41 6 �.� i 7 6 2 28 4 N 2 41 6 i 14 2 0 28 4 a 0 0 a 14 2 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 1pm 0 5 10 15 20 25 30 35 404 °P 5 50 55 60 gpm 5 7.5 10 15 fps 3 0 19 38 57 76 95 114 133 152 171 190 209 228 1pm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate AME S FIRE&WATERWORKS A Watts Water Technologies Company USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•Fax:(52)81-8000-7091 •AmesFireWater.com ES-A-2000B 1410 ©2014 Ames Fire&Waterworks FOR SMALL PIPE SRS P PcYrF1EJ . V VANE TYPE WATERFLOW s The Symbol of Protection ALARM SWITCH WITH RETARD Fig. 1 Fig.2 ,Retard Adjustment DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME now rox The time delay is factory set at 30±10 seconds. COVER.TvWu'ERSV.Ili CII ;— Thedelaycanbeadjustedbyrotatingtheretard I L i, I adjustment knob from 0 to the max setting(60- ���,' 0113111 I 11 90 seconds).The timedelay should beset at the �.�l tIi minimum required to prevent false alarms. .11w.- � !i� {�'�� \I �` Screw the device into the tee fitting as shown. I' !� ;4.--- 1.__.../NCare must be taken to properly orient the DIRECTION OF J MOUNT SO ��� waTFR FLOW 1 ARROW ON \ •>� device for the direction of waterflow.On sweat i0 l_:,c Rusl Nc,PORTS �� tees,no threaded bushings,inserts,or adapters IN DIRECTION OF wATERFIow ��_� are permitted,unless they comply with the 1`� dimensions listed in the chart below. THREADED a Important-The depth to the inside bottom of To'/ the tee should have the following dimensions: ES 4" _� � RW OF TIIF THF ��� Approximate Depth Requirement M\1 BF ^� There are 12 paddles furnished with each unit. THREADED OR V Tee Sue Threaded Sweat CPVC SN FAT PIPE \� One for each size of threaded,sweat or plastic ry x I'x r' 2 vI6" 13 4•' 2 716" DIRECTIONCTFRFIOF ���I,,. TEE as described�Fig.2.These paddles have wnTFRFIow `vvv� I 1/4"x I va"x I" 2 rIe" z z I6�� N/A raised lettering that shows the pipe size and type �Q W,r)o S I u2 x I u2'x 1" 2 11'16" 2 1/4" N/A of TEE that they are to be used with.The proper 2"x2"xl" 33,16" 2314" NIA paddlemustbeused.Thepaddlemustbeproperly Shown with optional Cover Tamper Switch Kit. attached(see drawing)and the screw that holds , T the paddle must be securely tightened. Do not use ntore than three wraps of teflon tape. Fig.3 Switch Terminal Connections Clamping Plate Terminal Fig.7 Cover Tamper Switch Wiring (Shown with cover in place) �i fr �o" _. �: '1. Jill • > An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections.The wire e O must be severed,thereby providing supervision of the connection in 00 the event that the wire become dislodged from under the terminal. C N.O. N.C.(WHT) (RED) (BLK) Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. DR 148810018.2 Fig.4 Typical Electrical Connections Fig.5 Fig.6 �II411, To remove knockouts: Breakoutthinsection ofcover when wiring r+1 NEUTRAL Ac OR Place screwdriver at edge of both switches from one conduit entrance. {J' I knockouts,not in the center. '_ IL: , 11 I4-1�III.. POSITIVE DC OR , 11HOT AC //)111_ �o�o•—u Ali i I =I V--— :+' WATERFL,OW ZONE ON ' o'er- [± Won 40 1 \1�;��1 SII. ,J , h►'�� '�\ I Notes: 11� 1. The Model VSR-S has two switches,one can be used to operate a "lie central station,proprietary or remote signaling unit,while the other u is used to operate a local audible or visual annunciator. u 2. For supervised circuits see"Switch Terminal Connections"drawing it and caution note(Fig.3). PRINTED IN USA MFG.45401206-REV G PAGE 2 OF 3 12/08 FOR SMALL PIPE V,�R-S P PcYf"f] VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Testing Removal I The frequency of inspection and testing for the Model VSR-S and its • To prevent accidental water damage,all control valves should associated protective monitoring system should be in accordance with be shut tight and the system completely drained before waterllow applicable NFPA Codes and Standards and/or the authority having detectors are removed or replaced. jurisdiction(manufacturer recommends quarterly or more frequently.) • Turn off electrical power to the detector,then disconnect wiring. An inspector's test valve(usually located at the end ofthe most remotebranch • Use a wrench on the flats of the bushing.Turn the switch line)should always be used for test purposes.If there are no provisions for counterclockwise to disengage the pipe threads. • testing the operation of the flow detection device on the system,application • Gently lift with your fingers,roll the vane so it will fit through the of the VSR-S is not recommended or advisable. hole while continuing to lift the waterflow detector. A minimum flow of 10 gpm(38 Lpm)is required to activate this device. • Lift detector clear of pipe. NOTICE Please advise the person responsible for testing of the A CAUTION fire protection system that this system must be tested in accordance with the testing instructions. Waterfiow switches that are monitoring wet pipe sprinklersystems Maintenance shall not be used as the sole initiating device to discharge AFFF, Inspect detectors monthly for leaks. If leaks are found, replace the deluge,or chemical suppression systems.Waterflow switches used detector.The VSR-S waterflow switch should provide years of trouble- for this application may result in unintended discharges caused free service.The retard and switch assembly are easily field replaceable. by surges,trapped air,or short retard times. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock#1029030.There is no maintenance required,only periodic testing and inspection. Mounting Dimensions 3.50" - 5.56" GROUND SCREWS (89.0 mm) (141.2 mm) 2.00" jam'ori:I,1,.I (50.8 mm) I �I _____ •I lii-i_i ISI i_i=i=il 2.34" 1 - nil [ , 1 44.89" _■ _.__.. liill----_t_. it.fr, n_,II (52.3 mm) I!J-.- o t -tt t/zNPr DWG#1206-5 PRINTED IN USA MFG.#5401206-REV G PAGE 3 OF 3 12,08 Model 1000 c® us ,�'� TESTANDRAIN® APPROVED 300 PSI Bronze Ball Valve MODEL 1000 - PLAN VIEW FRONT VIEW - HORIZONTAL INSTALL A E-�I Y I Ij O IF O' t 1/2"NPT SYSTEM _ TJ ''j � , ACCESS PORT ll J F �� PIM! TO DRAIN -----_J - TO DRAIN ! ,� \ CI, f -- H--�"5---- -_r (?,, *) \ -...," C O ' v/� 1 DIMENSIONS MATERIALS Orifice Size Available:3/8",7/16", 1/2", 17/32", ELO(5/8")*, ESFR(3/4")*,&K25** Handle:Steel Stem: Rod Brass SIZE A B C D E F G H Ball:C.P. Brass 3/4" 51/46" 11/2" 23/16" 35/8" 33/a" 113/46" 406" 64/8" Body: Bronze (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) Valve Seat: Impregnated Teflon® 51/46" 11/2" 23/46" 35/8" 34/8" 113/16" 406" 6�8" Indicator Plate:Steel 1" Handle Stop:Steel (128 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 57/16" 111/16" 29/46" 41/4" 35/16" 115/16" 59/16" 51/2" APPROVALS 11/4„ (163 mm) (43 mm) (65 mm) (108 mm) (83 mm) (51 mm) (141 mm) (192 mm) UL and ULC Listed(EX4019) 11/2" 67/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" FM Approved (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) NYC-BSA No.720-87-SM 2" 67/16" 113/46" 31/4" 51/16" 37/9" 25/8" 81/4" 107/a" (163 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4"to 2"size units only **Available on 11/2"and 2" size units only �1 THE MODEL 1000 PROVIDES ALL OF THE FOLLOWING... MADE IN U.S.A. From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections,interior sectional or floor control valve(s)—shall be provided with a drain &8.16.2.4.3 connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location...downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice,to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1",at least one of which shall be brass. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: GA100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 Architect: Fax:610-240-4906 Engineer: www.testandrain.com Contractor: Atef7: 71§§§) P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER 41 0 ^ 510 Fastener SIZE Dim rt 3/4 2.125 0 1 2.312 1 1/4 3.170 1 1/2 3.400 2 4.010 2 1/2 4.320 3 5.320 SIZE-SYSTEM PIPE: 3/4"thru 3" MATERIAL-Carbon Steel. FINISH-Mil. Galvanized. LISTING/APPROVAL- 7fJ 0" 4231,EX 2551USTED FUNCTION-Support horizontal piping: CPVC,Copper or Steel. Size 3/4" -2"Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION- Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS- UL Listed per NFPA 13 in WOOD: 3/4" -3"CPVC pipe-#905 screw-no pre-drill. 3/4" -3"Steel and Copper pipe-#14 x 1 1/2" SMS or 1/4"x11/2" lag bolt-no pre-drill. Restraint in STEEL-min. 18 GA. 3/4" -3"CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw. i --� FEATURES *Offset edge eliminates abrasion. p. *Retainer dimples secure hanger to pipe during installation. * Required AFCON#905 screw included-5/16"hex head. Hanger le a. Stabilize ORDERING-Part#and pipe size. 111 I I CAN ALSO BE USED TO REPLACE -#500 Pipe Strap #520 Tin Strap Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-A[CON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any director indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON product,have been,or are used. 5/14