Report (121) c1<M SSU ke' -ia- b . • ticti Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-B — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General be consulted with respect to the suit- ability of these coatings for any given Description corrosive environment.The effects of ambient temperature,concentration of The TYCO Series TY-B, 2.8, 5.6, and chemicals,and gas/chemical velocity, < ti ''' should be considered,as a minimum, 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet along with the corrosive nature of the are standard response - standard chemical to which the sprinklers will be coverage,decorative 5 mm glass bulb exposed. type spray sprinklers designed for use An intermediate level version of the 0 '. in light,ordinary,or extra hazard,corn- Series TY-B Pendent Sprinkler can be <" i"• mercial occupancies such as banks, obtained by utilizing the Series TY-B '. - .: hotels, shopping malls, factories, Pendent Sprinkler in combination with refineries,and chemical plants. the Model S2 Shield. The recessed version of the Series TY-B Pendent Sprinkler, where appli- NOTICE cable, is intended for use in areas with The Series TY-B Sprinklers described a finished ceiling. It uses a two-piece herein must be installed and maintained or ' " .- Style 10(1/2 inch NPT)or Style 40(3/4 in compliance with this document,as S inch NPT)Recessed Escutcheon.The well as with the applicable standards Recessed Escutcheon provides 1/2 of the National Fire Protection Associa- (P" inch(12,7 mm)of recessed adjustment tion,in addition to the standards of any or up to 3/4 inch (19,1 mm) of total other authorities having jurisdiction. �` adjustment from the flush pendent Failure to do so may impair the perfor- position. The adjustment provided by mance of these devices. the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops The owner is responsible for maintain- x' M in their fire r to the sprinklers must be cut. 9 protection system and devices in proper operating condition. Corrosion resistant coatings, where The installing contractor or sprinkler applicable, are utilized to extend the manufacturer should be contacted with life of copper alloy sprinklers beyond any questions. that which would otherwise be obtained when exposed to corrosive atmo- spheres.Although corrosion resistant Sprinkler coated sprinklers have passed the Identification standard corrosion tests of the appli- cable approval agencies, the testing Numbers is not representative of all possible corrosive atmospheres.Consequently, it is recommended that the end user TY1151 Upright 2.8K, 1/2"NPT TY1251 Pendent 2.8K, 1/2"NPT TY3151 Upright 5.6K, 1/2"NPT TY3251 Pendent 5.6K, 1/2"NPT TY4151 Upright 8.0K,3/4"NPT IMPORTANT TY4251 Pendent 8.0K,3/4"NPT Always refer to Technical Data TY4851 Upright 8.0K, 1/2"NPT Sheet TFP700 for the "INSTALLER TY4951 Pendent 8.0K, 1/2"NPT WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 FEBRUARY 2014 TFP151 ' TFP151 Page 2 of 8 S CEILING PLATE 1 Frame 5 Compression SEATING SURFACE 2 - Button Screw T 7 3 - Sealing 6 - Deflector* e 110--..'r'.! ..1.:_i-I TI 1 Assembly 7 - Bushing 1 4 - Bulb 7/16" _.____ immi21/4.. 3 (11,1 mm) (57,2 mm) .to 'R`,_; git r MAKE-INL 2 *Temperature rating is indicated on Deflector. t�r 2-3/16" I 1 9/16" 4 (55,6 mm) (39,7 mm) 5 ** Pipe thread connections \ 1 � � per ISO 7-1 can be /�•�\ 1 %i��� 6* provided on special 1/2"NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE T'i' =-----------=.-'-------7/16" -f , I$A A ��1'�� N10MINAL 2-3/16.. M11 6-----.=-I M - 2 MAKE IN (55,6 mm) r 4 (55 6 mm) ' 1 1/2" �`i (38,1 mm) 411 {—.2 ----5 6* 1/2" NPT** t WRENCH STYLE 10 I---. 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE S 0 . a • TFP151 Page 3 of 8 0 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* /SURFACE. _ __.. -i-----� y _ 1 1/2" 4AØ3 FI (12,7 mm) rNOMINAL 1 2-5/16" �-„4_4 2 �� I (587 mm) A r 1 21/4” 1-9/16" f 4 1 (57,2 mm) (39,7 mm) 3/4"NPT** I WRENCH STYLE 40 [ 2-7/8"(7 )DIA. —.- - -- 6* FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT,STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 Sealing 6 Deflector* w-r'----nt 1 t Assembly liltN7/16" I 3 4 Bulb (11,1 mm) �' 2-1 f4" OMINAL I I (57,2 mm) IA4 2 III MAKE-IN / 1 A + *Temperature rating is 4110 ` � 2-3/16" 1p 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 ma)) II ���5 ** Pipe thread connections \ _ 1 -11—` \-- 6* per ISO 7-1 can be provided on special 1/2"NPT** I WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE • TFP151 Page 4 of 8 1110 SPRINKLER FINISH(See Note 8) • TYPE TEMP. BULB WAX OVER LIQUID NATURAL CHROME POLYES- LEAD WAX LEAD BRASS PLATED TER*** COATED COATED COATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red 2.8 (T and 1) 175°F(79°C) Yellow 1,2,3 1/2 PENDENT N/A NPT (TY1251) 200°F(93°C) Green Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TYand 3151) 175°F(79°C) Yellow 1,2,3,5 1,2,3,5 PENDENT 200°F(93°C) Green 1,2,3,4,5,6,7 1,2,3,5 (TY3251) Figure 2 286°F(141°C) Blue 1** 2** 3°° 5** 1** 2** 3** 5** 5.6 1/2" 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT1,2,3,4,5 (TY3251)* 175°F(79°C) Yellow N/A Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (T and 1) 1,2 3 5 1 2 5 175°F(79°C) Yellow PENDENT 1,2,3,4,5,6,7 1,2,5 (TY4251) 200°F(93°C) Green Figure 3 286°F(141°C) Blue 1** 2** 3** 5** 1** 2** 5** 8.0 3/4" 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT1,2,3,4,5 (TY4251)* 175°F(79°C) Yellow N/A Figure 6 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red 8.0 (T and 1) 175°F(79°C) Yellow 1/2" PENDENT1,2,3,4,5,6 N/A NPT (EN200°F(93°C) Green Figure 4 286°F(141°C) Blue 360°F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) 3. Approved by Factory Mutual Research Corporation(FM) 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) 5. Approved by the City of New York under MEA 354-01-E 6. VdS Approved(For details contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be FM Ap- proved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable ** 150°F(66°C)Maximum Ceiling Temperature "** Frame and deflector only. TABLE A • SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 5 of 8 SPRINKLER FINISH TYPE NATURAL CHROME LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 2.8 UPRIGHT(TY1151) /2" and 175 PSI(12,1 BAR) N/A PENDENT(TY1251) UPRIGHT(TY3151) and 5.6 PENDENT(TY3251) 250 PSI(17,2 BAR) 1/2"" OR NPT 175 PSI(12,1 BAR) RECESSED PENDENT (SEE NOTE 1) (TY3251) UPRIGHT(TY4151) and 175 PSI(12,1 BAR) 8.0 PENDENT(TY4251) 3/4" NPT RECESSED PENDENT 175 PSI(12,1 BAR) N/A (TY4251) 8.0 UPRIGHT(TY4851) • 1/2" and 175 PSI(12,1 BAR) NPT PENDENT(TY4951) NOTE • maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Physical Characteristics Design Frame Bronze Data Button Brass/Copper Criteria Sealing Assembly Beryllium Nickel w/ TEFLON The TYCO Series TY-B, 2.8, 5.6, and Approvals Bulb Glass UL and C-UL Listed Compression Screw Bronze 8.0 K-factor, Upright and Pendent FM, LPCB, VdS, and NYC Approved Deflector Copper Sprinklers are intended for fire protec (Refer to Table A for complete approval Bushing(K=2.8) Bronze tion systems designed in accordance with the standard installation rules information including corrosion resis tant status.) recognized by the applicable Listing Operation or Approval agency (for example, UL Maximum Working Pressure The glass bulb contains a fluid which Listing is based on the requirements of NFPA 13,and FM Approval is based Refer to Table B expands when exposed to heat.When the rated temperature is reached, the on the requirements Shee of the FM Loss Discharge Coefficient p Prevention Data Sheets).Only the Style K = 2.8 GPM/psit/2 (40,3 LPM/bar1/2) fluid expands sufficiently to shatter the 10 or 40 Recessed Escutcheon, as K = 5.6 GPM/psi1/2 (80,6 LPM/bars/2) glass bulb, allowing the sprinkler to applicable, is to be used for recessed K=8.0 GPM/psit/2(115,2 LPM/bars/2) activate and water to flow. pendent installations. Temperature Ratings e to Table A Finishes Sprinkler: Refer to Table C Recessed Escutcheon:Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass • TFP151 Page 6 of 8 2-7/8"DIA. G- (73,0 mm) 5/8±1/4" 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) WRENCH RECESS FACE OF (57,2 mm) MOUNTING (END"A"USED FOR SPRINKLER PLATE ^, 1/2"NPT MODELS) FITTING .0- 1 � / 1/8" (3,2 mm) WRENCH RECESS ' G1II (END"B"USED FOR j/ -I V j 3/4"NPT MODELS) ,� FIGURE 7 §,1 tW-TYPE 6 MOUNTING SPRINKLER WRENCH SURFACE - s CLOSURE SERIES 1-1/4"(31,8 mm) WRENCH TY-B 3/4"(19,1 mm) RECESS FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT l STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT t _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) %w, Y (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) PUSH WRENCH (57,2 mm) MOUNTING IN TO ENSURE FACE OF ENGAGEMENT SPRINKLER PLATE WITH SPRINKLER FITTING WRENCHING AREA ,, , , 1/8 FIGURE 8 0 • / (3,2 mm) r r W--TYPE 7 RECESSED „7,,„_i_ �� SPRINKLER WRENCH �,�� 1 Installation MOUNTING �. SURFACE The TYCO Series TY-B, 2.8, 5.6, and ---------• 8.0 K-factor, Upright and Pendent CLOSURE SERIES 1-5/16"(33,3 mm) Sprinklers must be installed in accor- TY-B 13/16"(20,6 mm) dance with this section. FIGURE 6 General Instructions SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY Do not install any bulb type sprinkler if WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT the bulb is cracked or there is a loss of STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT liquid from the bulb.With the sprinkler held horizontally, a small air bubble should be present.The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs.(9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-lbs.(13,4 to 26,8 Nm).Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. • . • i • TFP151 Page 7of8 0 Do not attempt to make-up for insuf- Recessed Pendent Sprinklers Care must be exercised to avoid dam- ficient adjustment in the escutcheon The Series TY-B Recessed Pendent age to the sprinklers before,during,and plate by under-or over-tightening the Sprinklers must be installed in accor- after installation. Sprinklers damaged sprinkler. Readjust the position of the dance with the following instructions. by dropping, striking, wrench twist/ sprinkler fitting to suit. slippage,or the like,must be replaced. Step A. After installing the Style 10 Also, replace any sprinkler that has a Upright and Pendent Sprinklers or 40 Mounting Plate, as applicable, cracked bulb or that has lost liquid from The Series TY-B Upright and Pendent over the sprinkler threads and with its bulb.(Ref. Installation Section.) Sprinklers must be installed in accor- pipe-thread sealant applied to the pipe dance with the following instructions. threads,hand-tighten the sprinkler into The owner is responsible for the Step1. Install the sprinkler fitting. inspection,testing,and maintenance of pendent sprinklers in their fire protection system and devices the pendent position; install upright Step B. Tighten the sprinkler into the in compliance with this document, as sprinklers in the upright position. sprinkler fitting using only the W-Type well as with the applicable standards 7 Recessed Sprinkler Wrench(Figure of the National Fire Protection Associa- Step 2. With pipe-thread sealant 8).With reference to Figure 3 or 4,the applied to the pipe threads, hand- W-Type 7 Recessed Sprinkler Wrench tion(e.g., NFPA 25), in addition to the tighten the sprinkler into the sprinklerto thestandards of any other authorities hav- fitting. sprinkler wrench flats. ing jurisdiction. Contact the installing Step C.After the ceiling is installed or contractor or sprinkler manufacturer Step 3.Tighten the sprinkler into the the finish coat is applied, slide on the regarding any questions. sprinkler fitting using only the W-Type Style 10 or 40 Closure over the Series 6 Sprinkler Wrench (Figure 7). For TY-B Sprinkler and push the Closure Automatic sprinklers are recommended wax-coated sprinklers, use an 8 or over the Mounting Plate until its flange to be inspected,tested,and maintained 10 inch adjustable Crescent wrench. contacts the ceiling. by a qualified Inspection Service in With reference to Figures 1 through 4, accordance with local requirements . apply the W-Type 7 Sprinkler Wrench and/or national codes. or the adjustable Crescent wrench, Care and as applicable is to be applied to the Maintenance flats. Maintenance When installing wax-coated sprinklers The TYCO Series TY-B, 2.8, 5.6, and with the adjustable Crescent wrench, 8.0 K-factor, Upright and Pendent exercise care to prevent damage to the Sprinklers must be maintained and ser- wax coating on the sprinkler wrench viced in accordance with this section. I. flats or frame arms and,consequently, exposure of bare metal to the corrosive Before closing a fire protection system environment. Open the jaws of the main control valve for maintenance wrench sufficiently wide to pass over work on the fire protection system the wrench flats without damaging the that it controls, obtain permission to wax coating. Before wrench tightening shut down the affected fire protection the sprinkler, adjust the jaws of the system from the proper authorities wrench to contact only the sprinkler and notify all personnel who may be wrench flats. After wrench tightening affected by this action. the sprinkler, loosen the wrench jaws The owner must assure that the before removing the wrench. sprinklers are not used for hanging After installation, inspect the sprinkler any objects and that the sprinklers are wrench flats and frame arms and only cleaned by means of gently dust- retouch(repair the wax coating when- ing with a feather duster; otherwise, ever the coating has been damaged non-operation in the event of a fire or and bare metal is exposed. Retouch inadvertent operation may result. the wax coating on the wrench flats Absence of an escutcheon, which is by gently applying a heated 1/8 inch used to cover a clearance, may delay diameter steel rod to the damaged the time to sprinkler operation in a fire areas of wax, to smooth it back over situation. areas where bare metal is exposed. Sprinklers which are found to be leak- NOTICE ing or exhibiting visible signs of corro- sion must be replaced. Only retouching of the wax coating Automatic sprinklers must never be applied to the wrench flats and frame p arms is permitted, and the retouching painted, plated, coated, or otherwise is to be performed only at the time of altered after leaving the factory. the initial sprinkler installation. Modified sprinklers must be replaced. Sprinklers that have been exposed to The steel rod should be heated only to corrosive products of combustion,but the point at which it can begin to melt have not operated,should be replaced the wax,and appropriate precautions if they cannot be completely cleaned need to be taken when handling the by wiping the sprinkler with a cloth or ill heated rod in order to prevent the installer from being burned. by brushing it with a soft bristle brush. 4 • TFP151 Page 8 of 8 P/N 57 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS r C 30 2.8K UPRIGHT(1/2-NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2-NPT) TY1251 3 PURE WHITE(RAL9010)" 155 155°F(68°C) POLYESTER 570 5.6K UPRIGHT(1/2"NPT) TY3151 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 571 5.6K PENDENT(1/2"NPT) TY3251 5 JET BLACK(RAL9005)" 200 200°F(93°C) POLYESTER 590 8.0K UPRIGHT(3/4"NPT) TY4151 6 WAX COATED 286 286°F(141°C) 286°F(141°C)MAX 591 8.0K PENDENT(3/4"NPT) TY4251 7 LEAD COATED 360 360°F(182°C) 560 8.0K UPRIGHT(1/2"NPT) TY4851 8 WAX OVER LEAD 000 OPEN*** 286°F(141°C)MAX 561 8.0K PENDENT 1/2""NPT TY4951 9 CHROME PLATED ***Available-fctronly for 8.0d ( ) K-factor TY4151 and TY4251 for use in Deluge *Eastern Hemisphere sales only Systems.(OPEN **Available in only 8.0K,155°F(68°C) indicates sprinkler or 200°F(93°C);requires lead time to assembly without glass manufacture. bulb,button,and sealing assembly.) TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS • PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N(Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with(specify)finish,P/N* "Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 S GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. Vico i.:FLON!s trademark of The DuPont Corporation. Fire Protection Products