As requested,special inspection of the installation of Terra Firma push piers was conducted on June 14,2018.The repair
involved placement of 7 push piers,as shown on the plans from this office dated 5/16/2018.The push piers were installed
beyond the minimum installation pressure of 1350 psi(4'A"RAM)and the minimum depth of 8 feet.Each pier installation is
acceptable regarding project requirements.It is noted that the EOR approved the change of location of the piers.
TABLE 1—PUSH PIER DRIVE LOG DETAILS
Plan Pier Number Installation Depth(feet) Installation Pressure(psi)
1 40 1400
2 43 1400
3 43 1400
4 61 1700
5 43 1800
6 61 1900
7 70 2200
The provided special inspection has been performed to meet the requirements of current building code and does not
establish a guarantee of the contractor's work.It is the responsibility of the contractor to perform the work in accordance
with the provided structural drawings and the specifications of Foundation Supportworks.
Thank you for the opportunity to be of service.If you have any questions or concerns regarding this report,feel free to let
us know.
Sincerely,
4.0 PRO, 7.12.18
����c'1NF d>0.
6 t{ royal@mortiereng.com
11/ or Ge '1{'E - Royal Mortier, PE 2018.07.12
16:04:56-07'00'
•RE ON
; DIGITAL SIGNATURE FOR VERIFICATION OF ELECTRONICALLY
4 7.C•>1`<_ / TRANSIMITTED DOCUMENTS ONLY. SIGNATURE WILL AUTOMATICALLY
MO VOID IF DOCUMENT IS MANIPULATED ELECTRONICALLY.
EXPIE _S; 2f3ii1 N Royal Mortier,P.E.
Royal Mortier,P.E. RM/ja