Plans (7)
M EC2017 - 0099 1 `1 - r: O U - HVAC-DESIGN PROCEDURE 1'LINE VOLTAGE) A. - - - • - - - - - - - -- - USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.VA.C.SYSTEM PER DESIGN STANDARDS e X c e 1 LISTED BELOW. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR - - REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. L] INCLUDE THE FOLLOWING: HVAC 2-2'LOW VOLTAGE - 23'-3" 8'-5" a. DUCTING AND SIZES HVAC INC.I I -0 1,._ 2- VOLTAGE - /� b. SUPPLY AND RETURN LOCATIONS AND CFM c. ROOF EQUIPMENT,SIZES AND LOCATIONS OFFICE COPY 2-2"LOW VOLTAGE ) d. UNITS REQUIRING DUCTED SMOKE DETECTION 1•LINE VOLTAGE �% I IL e. THERMOSTAT LOCATIONS AND ZONENNIT ASSOCIATED THEREWITH \� � I f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS EXCEL HVAC INC. a"IL , 21'-5" 10-5" II g. ZONE DIAGRAM P.O. BOX 1188 HVAC DESIGN STANDARDS CANBY, OR 97013 (E)• )) n THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: PHONE: 971-930-7194 1 I �Q 13. 350 SQUARE FOOT PER TON. JEREMY@EXCELHVAC.NET 4-TON 14. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY D A �` • oAq 8 Ac • CONFERENCE \ aTEN NT PRIOR TO EXTERIOR EXPOSUREAREAS CCB# 214345 0 D tea"' 250 12 169 12 b. INTERIOR AREAS,SIZE AND USE . i ) �- A. 400 t a 400 011 O2 g C. CONFERENCE/TRAINING ROOMS O 1 I HARED ❑F-F ■ E I C E � 57 \ d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION 11 167 © 168 - 14"0 • r AND 24-HOUR USE. �p•.•,g� (� I� 14"0 •� 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. Q 4 EC E II E D n11 1/2" PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. �12"0 10 i 8 61, '1 / 14 © VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. DEC 12 2017 2 , ., �\ 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY 8 RETURN GRILLES. CITY OF TIGARD III R .-1 • 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. BUILDING DIVISIONI6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 14"0 2 (N)N +:'� TONS SHALL HAVE SPECIAL APPROVAL BY BUILDING OWNER. dth '` 7. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE - - CONNECTED TO A MONITORING STATION WITHIN THE BUILDING. �$ 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS _ SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. 00 �( 123 { 14"0 - DEFT' E IFiD 9. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW �, ROOFING. Ina, ❑PEN OFFICE ` a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF PROJECT NUMBER: Lr $ - 14"0 - - 16 6 p _ ` CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. iiil y b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. 250 - `� I, 14X6 14X6 14X6 14X6 14X6 14"0 14X6 • C. CONDENSATE MUST BE TRAPPED AT UNIT. Y10. SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. 333 333 333 333 333 333 ' 10 hillI I 11 11 f-I I-I 1-1 I-I I I 11. ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN LJ ta LJ OFFICE INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND REVISIONS: DATE Q V Aril E 14X6,18"0 14X6 �16"0 14X6 12 ' �._ CLAMPED(S.S.WORM GEAR). • 333 3 �) 333 18� / -8 12. ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND r 2-TON y2_4„ �) 400 CORROSION WITH OIL BASED PAINT(COLOR GREY). t $ 9' 9'_yy„ 3TON 16„O 10 _ / 13. LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND• 12"0 � ` 10"0 I ill 300 RADIUS MANUFACTURER'S GUIDELINE. = =JJ.•-♦ - -, .. �- 8_ �- 14. ECONOMIZER TO MEET CODE AND AS FOLLOWS: 7 b•Il_, i _ I I , 1• ' a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. ►fi �,� ��Tii �' � 10 b. BAROMETRIC RELIEF ON 5-71/2 TON UNITS. P4 i es 7 ,$ _ ‘r-----8 III 6 6 6 I 16„0 i 14"0 =• I 1=��� N , 8 200 IIS • 100 100 F): H /1 ' F I C c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. r _ a 12 14"0 d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. 4'-� , © ❑F E I C • - - - a� 15. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. 1. r 1 8"0 '1 11 175 A '1 400 11 E-PSC ■3<*.sr• 10 16. DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WITH SUPPLY AIR. EDGES OF w -'-7 177 „ iii 300 SUPPLY AIR SEALED. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING. Cl)z2o1`�� Ail 173 I ❑ EN OFFICE V1 ....----.7. ,,� pkI - . , p ,_ 17. DISTRIBUTION DUCTWORK: 10"0179 �_ ql12"0 a. SPIRAL ONLY IF EXPOSED. 10 �al - YP 4P ' - 12"0 b. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. 300 C IR C 14„0 _ . WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH 111. FrA / -$ O ❑F I - MINIMUM R5 INSULATION WITH FOIL BACKED FSK OR BUBBLE WRAP. 41(1rT4 4�u/ 176 140 10-- " C N E. f0 co (E)12"0 9. 7 E E IC �' - 12 d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD' HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE - ❑FFI ' I 18.»-I',_ 187 10 (E)12"0 �� IC II © ,111® e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 / 1� r _ DEGREES. W 8 200 !tilt% 14 E•scM �'LI14 1Ipf. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. O IIII '=' , g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. ' I , •, ,-, ,. . ' 17 8. �I _ 18. FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. H woo LP C , LP P-PSC q5� 0 , ❑F F / _ 19. DIFFUSERS: u, § 5-TON ease LP 183 10 a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN 13,_0„ 12 12"(� w - TITUS PCS SUPPLYANDTITUS PAR RETURN OR APPROVED EQUAL. J a (E) 12 300 0. (E) 8 / 16 -- - „ 400 gli 10 b. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-DESIGN L� a 3 TON ' 2 TON � � I TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x ill"EGG CRATE DESIGN TITUS SOF.II H 200 �) lir C. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT/OR NEAR CLOSEST II® $ 1010 1010 WYE BRANCH. _ 200 ❑P E N E I CE 305 305 " 12"0 (E) V \ 305 -320 - d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT$ 12"0 -- COMPLETION. 200 _ lab 5-TON 16"0 20. THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE 411( OFFICE v � / '�W F R - HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE 12"0 1T-1" 1 S 4 POSSIBLE. APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO. H 1 91 "•�--� - P3742800 -7A 7 DAY PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA i '' 14"0 14"0 / HEIGHT(MAY REQUIRE CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM THERMOSTATS AND BALANCE SYSTEM. © „ 8 16'0 12"0 & o o , // 21. THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. T^ I ,) 10 '� 22. WAREHOUSE HEAT: v1 © / • i EXEC ❑ � 320 �� \ a. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE Irr DDD /p �� ENERGY CODE REQUIREMENTS. PROVIDE ADJUSTABLE T-STAT FOR EACH UNIT. 14/ / 18 S , 10 / 23. EXHAUST FANS: 8 ;t \ 10"0 J 8 10"0 a. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT Z 8 I 237 237 , CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. OFFICE a 10"0 r ./ COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A 192 SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. O - r& b. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING $ �� '- �. 8 N 8 8 - _ MOUNTED EXHAUST FANS,WIRED PER DIVISION 16 AND SWITCHED WITH THE LIGHTS. o 2b0 238 , dth / 238 " 22 " 2 c. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE ROOFTOP MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED PER DIVISION 16, i , ,Y-- _ � f CONTROLS AS REQUIRED BY DESIGN.COOK ACED SERIES OR EQUAL. -- - - - -- -- - d. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,WILL REQUIRE THE USE OF A ROOFTOP MOUNTED FAN. 24'-6" 24. HVAC TESTING. _---- a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, ' EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH • APPROVED PLANS AND SPECIFICATIONS. P4 © HVAC PLAN /`', p - b. CNNS PION SHALL N FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN O ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. ® 1!8"=1'-0" - c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH PACTRUST. 25. PROJECT CLOSE OUT DOCUMENTS REQUIRED: 4' 2' 0' 4' 8' a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. - C. HARD COPY OF AutoCAD FILE ABOVE. -- - --- --- d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSTATS. OST EXPANSION EQUIPMENT SCHEDULE e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. IPLV TAG MANUF. MODEL TONNAGE CFM COOLING SEER HTG. AFUE VOLTAGE PHASE MCA MAX FUSE WEIGHT RTU-1 CARRIER 48VL-B240403 2-TON 800 22.94 14 40 MBH 81% 208/230 1 15.2 20 304 16290 SW UPPER BOONES FERRY PORTLAND, OR 97224 1 . ROOFTOP UNIT TO HAVE MANUAL OUTSIDE AIR HOOD 2. ALL RESTROOM EXHUAST IS EXISTING OFFICE COPY DESIGNER CONTACT: • ' CITY OF TIGARD JEREMY HUNT REVIEWED FOR CODE COMPLIANCE Approved:\�/, J QdAcscGA SII\I I� CAD! i OTC: i J Permit#t pet P r ani 7- 00 gig }' JH Address: 14.90 S w e q r r [3 o 0 nes Ferri-pm)" Suite#a 12/10/17 By: 1 Data )3-12--1-7 I SHEEP NUMBER! ._... . Ml