Plans (6) M EC2017 - 00775 LEED SYSTEM COMMISSIONING ABBREVIATIONS IAQ MANAGEMENT PLAN DUCTWORK AND ACCESSORIES GENERAL MECHANICAL NOTES i „ 3** DURING CONSTRUCTION, CONTRACTOR SHALL COMPLY WITH LEED EQ CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING * .. .. AFF ABOVE FINISHED FLOOR SHEET METAL DUCTWORK 1. MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE AHJ AUTHORITIES HAVING JURISDICTION CREDIT 3.1 AND CHAPTER 3 OF SMACNA'S IAQ GUIDELINES FOR OCCUPIED SEE SPECIFICATIONS FOR SHEET METAL DUCT REQUIREMENTS. ALLGENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING OCT 4 ��� BUILDINGS UNDER CONSTRUCTION. CONTRACTOR SHALL PERFORM AND CONTRACTOREQIREDTO SHALLDPROVIDEACPPORTAND WORKAS SPECIFIED, NEEDED AND APPROX APPROXIMATE EXPOSED DUCTWORK TO BE SPIRAL ROUND, OR RECTANGULAR LOCK- REQUIRED TO CONDUCT AND FACILITATE STARBUCKS STAFF BUILDING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO r r GAR' SUBMIT ALL INFORMATION AS REQUIRED BY LEED UNDER THE SUBMITTALS SEAM TYPE,AS SHOWN ON HVAC PLAN SHEET. ASSEMBLE AND INSTALL COMMISSIONING EFFORTS. THIS WORK WILL BE COMPRISED OF THREE DISTINCT REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF C leO a - BLDG BUILDING SECTION OF EQ CREDIT 3.1 AND OTHER SECTIONS. IF HVAC SYSTEM IS TO ACHIEVINGTW AIR TIGHT DLEAKAGE)AND NOISELESS INND(N OBPEACI ICE FOR EFFORTS: WORK. BUILPI1�fi �IVISIO BE USED DURING CONSTRUCTION, INSTALL MERV 8 FILTERS AT EACH (5% 1. SUPPORT STARBUCKS COMMISSIONING AGENT(CXA) DURING CO2 CARBON DIOXIDE RETURN AIR GRILL AND COMPLY WITH SMACNA'S GUIDELINES NOISE)SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. INSTALLATION VERIFICATION AND CORRECT DISCLOSED DEFICIENCIES. 2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT CD CEILING DIFFUSER REFERENCED BELOW. FURNISH AND INSTALL ALL REQUIRED DAMPERS, TRANSITIONS, 2. PERFORM TESTING,ADJUSTING, BALANCING AND SYSTEM STARTUP OR ARRANGEMENT OF SYSTEM(S). FURNISH & INSTALL ALL CLG CEILING CONNECTIONS TO AIR TERMINALS,AND OTHER ACCESSORIES NECESSARY AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS CXA; COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE CONST CONSTRUCTION FOR COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT 3. CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE A COMPLETE AND OPERATING SYSTEM. CXA COMMISSIONING AGENT ENERGY MANAGEMENT SYSTEM (EMS) CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION TESTING AND SUBMIT REPORTS. ©2017 STARBUCKS COFFEE COMPANY FROM THE ENGINEER. 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING DEG DEGREES DUCT SEALANT CONTRACTOR SHALL PERFORM AND PROVIDE THE FOLLOWING: CLEARANCES REQUIRED BY OTHER TRADES,AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANY DISCREPANCIES STARBUCKS COFFEE DM STARBUCKS DESIGN MANAGER THE GENERAL CONTRACTOR SHALL CONTACT AND COORDINATE PRIOR TO WITH THE ALL ARE TO DN DOWN INSTALLATION OF EMS STSTEM WITH STARBUCK'S VENDOR PRIOR TO LAST SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS PER SPECIFICATIONS. A. SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE , BUT ARE NOT THE FACE PROCEEDING THE FINISHED SURFACE WORK.UNLESS DIMENSIONSOTED OTHERWISE. COMPANY WEEK OF CONSTRUCTION. FURNISH AND INSTALL TEMPORARYLIMITED TO DOMESTIC HOT WATER GENERATION, HVAC SYSTEMS, DTL DETAIL COVER ALL ET, JOINTS AROUND SPIN-IN FITTINGS,AND ALL DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING 2401 UTAH AVENUE SOUTH DWG(S) DRAWING(S) THERMOSTATS AND SENSORS,AND ROUTE ALL LOW VOLTAGE WIRING FASTENING SCREWS WITH MASTIC. ROOFTOP UNITS, EXHAUST FANS, HVAC CONTROLS, LIGHTING CONTROLS, THROUGH EC PROVIDED CONDUITS (COORDINATE WITH ELECTRICAL). AIR CURTAINS, BUILT-IN REFRIGERATION, EQUIPMENT AND RENEWABLE DIMENSIONS. SEATTLE, WASHINGTON 98134 EA EACH EMS VENDOR TO PROVIDE ONE PERMANENT THERMOSTAT AND REMOTE SUPPORTS ENERGY SYSTEMS. 206 318-1575 EC ELECTRICAL CONTRACTOR PROVIDE FASTENERS,ANCHORS, RODS, STRAPS, TRIM,AND ANGLES FOR 4. THE MECHANICAL CONTRACTOR SHALL COORDINATE HVAC WORK ( I ECP EQUIPMENT CONTROL PAC SENSOR PER HVAC UNIT. LOCATE AND MOUNT THERMOSTAT(S)AND SUPPORT OF DUCTWORK. SUPPORTS MUST COMPLY WITH LOCAL B. CONTRACTOR SHALL PROVIDE WRITTEN RESPONSES TO ALL CXA'S WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS ANDONS SHALL TAKE PRECEDENCE OVER ALL OTHER THESE DRAWINGS AND SPECIFICATIONS ARE SENSOR(S) PER THE DRAWINGS. PROVIDE THERMOSTAT INDENTIFICATION SPECIFICATIONS EG EXHAUST GRILLE LABELS PER SPECIFICATION REQUIREMENTS. CONFIDENTIAL AND SHALL REMAIN THE SOLE REGULATIONS AND CODE. REVIEWS AND COMMENTS. RESPONSES SHALL BE PROVIDED INA ELEC ELECTRICAL TIMELY MANNER. DRAWINGS. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONSTY OF STARBUCKS CORPORATION, EM EMERGENCY DAMPERS FOR DIMENSIONED DIFFUSER LOCATIONS AND MOUNTING HEIGHTS EMS VENDOR TO PROGRAM, START-UP AND COMMISSION CONTROL WHICH IS THE OWNER OF THE COPYRIGHT IN EMS ENERGY MANAGEMENT SYSTEM SYSTEM. GENERAL CONTRACTOR IS TO COMPLETE FINAL CONNECTION PROVIDE VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS C. CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN PROJECT WHERE EXPOSED. SEE SPECIFICATION SHEETS FOR MECHANICAL THIS WORK. THEY SHALL NOT BE EXIST EXISTING AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN,AND EXHAUST SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE OF WORK FOR SPECIFICATION SECTIONS EXT EXTERIOR AFTER DATA RACK AND NETWORK INSTALLATION. GENERAL CONTRACTOR DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL WHICH CONTRACTOR IS RESPONSIBLE AND INTERVALS FOR WORK REPRODUCED (IN WHOLE OR IN PART), SHARED IS TO CONTACT EMS VENDOR TO VERIFY SYSTEM OPERATION AND 5. NEW DUCTWORK AND EQUIPMENT SHALL NOT BE INSTALLED WITH THIRD PARTIES OR USED IN ANY MANNER LISTED FIRE OR FIRE/SMOKE DAMPERS WHERE REQUIRED AND IN PERFORMED BY STARBUCKS CXA. CONTRACTOR SHALL SHOW TROUBLESHOOT IF REQUIRED. ON OTHER PROJECTS OR EXTENSIONS TO THIS F&I FURNISH & INSTALL ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVENIENTLY RESOURCES FOR PERFORMING ALL WORK RELATED TO COMMISSIONING WHERE IT OBSTRUCTS ANY EXISTING OR NEW AREAS THAT PROJECT WITHOUT THE PRIOR WRITTEN FLR FLOOR LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING ACTIVITIES ON A LINE ITEM IN THE SCHEDULE OF VALUES. REQUIRE ACCESS. CONSENT OF STARBUCKS CORPORATION. FT FOOT/FEET THE DAMPERS. PROVIDE MOTORIZED DAMPERS AT ALL INTAKE &EXHAUST THESE DRAWINGS AND SPECIFICATIONS ARE G GAS PIPING CONTROLS AND OPERATION NOTES BUILDING OPENINGS. COORDINATE WITH OTHER TRADES FOR ACCESS D. CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH THE INTENDED TO EXPRESS DESIGN INTENT FOR A PANELS, POWER AND FIRE ALARM INTERFACES. SEE SPECIFICATIONS FOR MANUFACTURER'S REQUIREMENTS AND ALL CONTRACT DOCUMENTS. PROTOTYPICAL STARBUCKS STORE (WHICH IS GC GENERAL CONTRACTOR FURTHER REQUIREMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED TOTALLY COMPLETE AND GENERAL. NOTES SUBJECT TO CHANGE AT ANYTIME)AND DO HR HOUR ACCESSIBLE TO STARBUCKS CXA FOR INSTALLATION VERIFICATION AND THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL THE NOT REFLECT ACTUAL SITE CONDITIONS. HVAC HEATING, VENTILATION,AIR CONDITIONING FOLLOWING COMPONENTS: GRILLES, REGISTERS,AND DIFFUSERS FUNCTIONAL PERFORMANCE TESTING PRIOR TO THE SCHEDULED START NEITHER PARTY SHALL HAVE ANY OBLIGATION GRILLES, REGISTERS,AND DIFFUSERS SHALL BE AS SPECIFIED AND SHALL OF INSTALLATION VERIFICATION. SCOPE NOR LIABILITY TO THE OTHER(EXCEPT STATED BE MECHANICAL CONTRACTOR SUPPLIED, UNLESS OTHERWISE NOTED. THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE I.D. INSIDE DIAMETER CONTROL WIRING ABOVE) UNTIL A WRITTEN AGREEMENT IS DIFFUSERS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND E. CONTRACTOR SHALL COMPLETE MANUFACTURER'S STARTUP A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE IAQ INDOOR AIR QUALITY THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL PROCEDURES PRIOR TO COMMISSIONING COORDINATION WITH CXA. MECHANICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL,AND FULLY EXECUTED BY BOTH PARTIES. WIRING IN CONDUIT NECESSARY FOR THE COMPLETE AND PROPER MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER EQUIPMENT NECEOSARY TO COMPLETE THE MECHANICAL WORK. LCP LIGHTING CONTROL PANEL OPERATING TEMPERATURE CONTROL SYSTEM INCLUDING ALL INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS PROJECT. F. CONTRACTOR SHALL BE READILY AVAILABLE DURING INSTALLATION STARBUCKS TEMPLATE VERSION i2017.05.18 LL LANDLORD MODES OF OPERATION AND INTERLOCK. VERIFICATION TO CORRECT ANY DEFICIENCIES OR DEFECTS IS CLOSED BY SITE EXAMINATION Eu PftuF- LV LOW VOLTAGE THERMAL INSULATION THE INSTALLATION VERIFICATIONPROCESS. CORRECTIONS SHALL BE THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL ,sCR ss, EXHAUST FANS 5 GIN[ o RESTROOM EXHAUST TO BE OPERATED IN CONJUNCTION PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR MADE IN A TIMELY MANNER WITHOUT DISRUPTION OF THE CONSTRUCTION AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED F+ y MAX MAXIMUMFAN(S) BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY SCHEDULE. AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE �- WITH STORE HOURS UNLESS OTHERWISE NOTED OR APPROVED OR CODE REQUIREMENTS OR ASHRAE 90.1-2004, WHICHEVER IS MORE PROPER INSTALLATION OF THE MECHANICAL WORK. MC MECHANICAL CONTRACTOR 7,108P, MECH MECHANICAL AS REQUIRED BY JURISDICTION (COORDINATE WITH ELECTRICAL). STRINGENT. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, G. ALL HVAC EXHAUST FAN AND AIR CURTAIN EQUIPMENT SHALL BE TESTED, MEP MECHANICAL, ELECTRICAL AND PLUMBING AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO ADJUSTED AND BALANCED BY THE CONTRACTOR'S TESTING,ADJUSTING PENETRATIONS MFG MANUFACTURER THERMOSTAT OREG� ' NOT EXTERNALLY INSULATE EXPOSED DUCTWORK AND PORTIONS OF AND BALANCE AGENT(SEE TESTING ADJUSTING AND BALANCING)AFTER WHERE PIPES AND DUCTS PENETRATE WALL, SEAL OPENINGS TO MIN MINIMUM PERMANENT THERMOSTAT(S)AND REMOTE SENSOR(S)SHALL BE DUCTWORK THAT ARE INTERNALLY LINED WITH CODE REQUIRED THE SYSTEM IS VERIFIED TO BE COMPLETE AND CORRECT BY STARBUCKS PREVENT AIR TRANSFER BETWEEN SPACES. USE FIRE RATED SEALANTS sFP g FURNISHED AND INSTALLED PER LEASE. ONE THERMOSTAT AND cQp"9 201a �� THICKNESS. INTERNALLY INSULATE EXPOSED SUPPLY DUCTWORK IF CXA, IN ACCORDANCE WITH THE REQUIREMENTS OF THESE DOCUMENTS. ON ALL FIRE SEPARATION PENETRATIONS, INCLUDING FLOORS. SEALCOA1 NTS NOT TO SCALE SENSOR IS PROVIDED FOR EACH AIR HANDLING UNIT. MOUNT ti M H9P THERMOSTAT(S)AND SENSOR(S) IN LOCATION& HEIGHT AS POSSIBILITY OF CONDENSATION. INTERNALLY INSULATE EXTERIOR ALL HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT AROUND ALL PIPES AND DUCTS PENETRATING FIRE SEPARATIONS WITH INCUBATED AND S. IN MECHANICAL CONTRACTOR& IGHTO PROVIDE DUCTWORK PER CODE. CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE NON-COMBUSTIBLE PACKING RETAINED BY METAL COLLARS. THE O.D. OUTSIDE DIMENSIONCALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE ASSEMBLY SHALL EE APPROVED BY STATE FIRE MARSHALL. S: Lh1 I� OSA OUTSIDE AIR THERMOSTAT IDENTIFICATION LABELS PER SPECIFICATION ' J ACOUSTICAL DUCT LINER PLANS AND SPECIFICATIONS. REQUIREMENTS. REFER TO THERMOSTAT SETUP INSTRUCTIONS SEQUENCES OF OPERATION SHALL BE BELOW FOR ADDITIONAL REQUIREMENTS. UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1"(25MM) TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH THE STANDARDS l REF REFERENCE ACOUSTICAL DUCT LINER IN SUPPLY AND RETURN DUCTWORK WITHIN 10'- CONTRACT REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE REQ'D REQUIRED 0" (305CM) OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. TESTING AND AIR BALANCE REPORT CONFORMING TO THE PROVISIONS OF CSA, ULC,ARL,ASME,ASTM, UL, NEMA,ANSI, SMACNA, REV REVISION •THERMOSTAT SETUP INSTRUCTIONS RT ROOFTOP PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE INCREASE DUCT SIZE INDICATED ON PLANS AS NEEDED TO REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE INFORMATION ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. HONEYWELL TH8320U THERMOSTAT. ACCOMMODATE LINER. LINER TO BE PROVIDED AND FASTENED TO DUCT SPECIFIED, ETC...TO THE STARBUCKS CXA IMMEDIATELY UPON GPD Engineering and Architecture SF SQUARE FEET 1. FOLLOW INSTRUCTIONS IN THE MANUAL WHICH COMES WITH MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMACNA AND COMPLETION OF THE WORK. CODES SPECIFICATION REQUIREMENTS. ALL WORK SHALL LE PERFORMED IN STRICT ACCORDANCE WITH ALL Professional Corporation SHT SHEET WITH THE THERMOSTAT. H. PROVIDE A LIST OF ALL FACTORY AND FIELD SETTINGS THAT HAVE BEEN APPLICABLE PROW"JCIAL AND LOCAL CODES AND ORDINANCES. IN CASE 520 SOUTH MAIN ST. SUITE 2531 SPECS SPECIFICATION(S) 2. CONFIGURE AS FOLLOWS: FLEXIBLE DUCTWORK PROGRAMMED INTO THE EQUIPMENT(SUCH AS SETPOINTS, SCHEDULES, OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE AKRON, OH 44311 SST STAINLESS STEEL A. DEGREES"F" DISPLAY FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS SHOWN IN PLAN AND DIP SWITCH SETTINGS, CONDENSER AND EVAPORATOR OPERATING CODES AND ORDINANCES, USE WHICHEVER IS MORE STRINGENT. THE P: 330.572.2100 F: 330.572.2101 B. 12 HOUR CLOCK NOT ABOVE HARD LID CEILINGS. FLEXIBLE DUCTWORK SHALL NOT EXCEED PRESSURE(TEMPERATURE, ETC...). MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A TEMP TEMPORARY C. CONTINUOUS FAN OPERATION IN OCCUPIED 5-0"(152CM) IN LENGTH AND TWO 45° ELBOWS. IT SHALL BE PULLED TAUT MINIMUM STANDARDWITHOUT ANY EXTRA COST TO STARBUCKS. GPD PROJECT NO: 2016355.37 TYP TYPICAL MODE AND APPROPRIATELY FASTENED TO RIGID BRANCH DUCT& DIFFUSER. I. CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN EQUIPMENT IS D. DISABLE KEYBOARD PROGRAMMING BENDS SHALL BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND. READY FOR FUNCTIONAL PERFORMANCE TESTING.ALL EQUIPMENT SHALL PERMITS AND FEES UNO UNLESS NOTED OTHERWISE 3. SET TIME AND DATE. SUPPORT BANDS SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT. BE READY FOR FUNCTIONAL PERFORMANCE TESTING PRIOR TO STARTING THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL 4. SET TO DISPLAY CURRENT TEMPERATURE. FLEXIBLE DUCTWORK SHALL MEET SPECIFICATION REQUIREMENTS. TESTING. THIS INCLUDES REHEARSING ALL FUNCTIONAL PERFORMANCE PERMITS, FEES,AND INSPECTIONS NECESSARY TO COMPLETE THE 'E WH WATER HEATER WSHP WATER SOURCE HEAT PUMP 5. SET OCCUPIED START TIME AT 30 MIN. BEFORE OPENING. SET UNOCCUPIED START TIME AT 30 MIN.AFTER CLOSING. TESTS BEFORE DEMONSTRATING TO THE CXA. CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS CXA AND VERIFY BY MECHANICAL WORK. ai VERIFY HOURS WITH STORE MANAGER OR o DEMONSTRATING THE CORRECT OPERATION OF EQUIPMENT, SENSOR WARRANTY t CONSTRUCTION MANAGER. CALIBRATION, RESPONSE OF ACTUATORS AND PROPER EXECUTION OF THE MECHANICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT MECHANICAL SYMBOL LEGEND 6. SET POINTS SHALL BE AS FOLLOWS OR AS APPROPRIATE HVAC EQUIPMENT AND MATERIALS HVAC CONTROL AND LIGHTING SEQUENCES, INCLUDING BUT NOT LIMITED ALL WORK TO BE MEE OF DEFECTS IN MATERIAL AND WORKMANSHIP T FOR CLIMATE: �L W TO AIR MOVEMENT, TEMPERATURE, SOUND AND CONTROL RESPONSE. FOR A PERIOD OF ONE (1)YEAR FROM THE DATE OF FINAL ACCEPTANCE aA. OCCUPIED (5° F DEADBAND) (3° C DEADBAND) AIR HANDLING UNITS PROVIDE ANY SECURITY ACCESS, HARDWARE, SOFTWARE OR OTHER BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK _ Ili_ COOLING: 75° F(24° C)I. HEATING: 70° F (21° C) AIR HANDLING UNITS SHALL BE AS SPECIFIED IN THE MECHANICAL SUPPORT AS NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING CO Y_. Y TYPICAL SUPPLY DUCT UP/DN e DUCT HEATER B. UNOCCUPIED SCHEDULE AND SHALL BE FURNISHED AND INSTALLED PER THE LEASE WITNESS AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS I. HEATING: 60° F(15° C) Nu- AGREEMENT. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR WILL RECORD THE EQUIPMENT OPERATION AND RESPONSE TO TESTING AND WORKMANSHIP. MANUAL VOLUME COORDINATING DELIVERY, PROVIDING COMPLETE INSTALLATION SEQUENCES AND PREPARE A LIST OF ANY DEFICIENCIES DISCLOSED BY ,max i O TYPICAL RETURN OR I II. COOLING: 78° F (25° C) W / EXHAUST DUCT DAMPER 7. SET TWO (2) HOUR OCCUPIED OVERRIDE FUNCTION TO INCLUDING CURBS, PIPING,VIBRATION ISOLATION,AND NECESSARY THE FUNCTIONAL PERFORMANCE TESTS FOR CORRECTION BY THE LEED ACCESSORIES,AND PROVIDING WARRANTY. CONTRACTOR. EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO,AIR ALL WORK, MATERIALS AND EQUIPMENT SHALL MEET LEED UP/DN PROVIDE THE FOLLOWING SET POINT OVERRIDES: U co m BACK DRAFT DAMPER A. HEATING: +2° F (1° C) HANDLING UNITS, ROOFTOP AND SPLIT TYPE, CONDENSING UNITS, REQUIREMENTS &CODE. IN CASE OF CONFLICT,THE HIGHER STANDARD N TURNING VANES ' B COOLING: -2° F(1°C) FILTERS EXHAUST FANS, LIGHTING CONTROLS, ETC... DELIVERABLES: PROVIDE SHALL APPLY. > N i r IF OPERATING HVAC DURING CONSTRUCTION, PROVIDE THREE (3)SETS COMPLETED COPIES OF ALL START UP REPORTS, FILLED OUT ON THE > — N 0 SMOKE DETECTOR OF 2"(51MM) MERV6 PLEATED DISPOSABLE FILTERS(OR HIGHER RATING MANUFACTURER'S FORMS, TO THE STARBUCKS CXA. T uj UQ Ci) U ' IF REQUIRED BY LEED). USE ONE SET UNTIL COMPLETION OF 2 to EF-1 EQUIPMENT DESIGNATION CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION J. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR LL <g 4 COMBINATION TESTING, ADJUSTING, BALANCING (PRIOR TO TAB)AND DELIVER ONE SET OF MERV13 FILTERS TO DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL PERFORMANCE W ( ' ft a N SMOKE AND FIRE 2 v O > v o (T) THERMOSTAT DAMPER STARBUCKS LABELED TO DENOTE THEIR RESPECTIVE TESTING PROCESS. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER CITY OF TIGARD Z cC 5. AIR HANDLING UNIT. WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. SPIN-IN TAKE-OFF INDEPENDENT AIR BALANCE CONTRACTOR OR QUALIFIED MECHANICAL — Q REVIEWED POR COD COMPLIANCE — I— M (e) THERMOSTAT SENSOR co a 1.0 r ,' AND VOLUME CONTRACTOR SHALL ACCURATELY BALANCE THE SUPPLY, RETURN AND EXHAUST FANS K. CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE-TESTING OF U U r to I DAMPER OUTSIDE AIR(INCLUDING EXHAUST FAN(S))AND HYDRONIC (WHERE EXHAUST FANS SHALL BE AS SPECIFIED AND PROVIDED PER THE LEASE EQUIPMENT DEEMED NECESSARY BY STARBUCKS CXA DURING Approved: �` cc W W o Q APPLICABLE) SYSTEMS TO PROVIDE AIR AND WATER QUANTITIES INDICATED C 10G� I(�I`o INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING. — SUPPLY AIR ARROW UNDERCUT DOOR AGREEMENT. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR OTC: [ O 3 ~ Ur O ON THE DRAWINGS AND IN THIS SPECIFICATION. BALANCER SHALL BE COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR 0^ — aD QUALIFIED FOR TAB WORK PER NEBB OR AABC STANDARDS. OPERATE Permit#: l -- ., a LL D- r— 1-- AND AIR ARROW CONNECT TO EXISTING AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS. SUBMIT TWO 2 AND INTAKES, PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, DEFICIENCIES FOUND IN THE SYSTEM DURING ANY AND ALL RE-TESTING. E �`s O BACKDRAFT DAMPER, DUCTWORK FROM RESTROOM GRILLE TO UNIT, CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT Address: Za ( - (s (Fc 0 COPIES OF THE BALANCE REPORT TO THE ENGINEER AND COMMISSIONING NECESSARY ACCESSORIES AND PROVIDING WARRANTY. DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. �— O AGENT FOR APPROVAL. INCLUDE A COPY OF THE BALANCE REPORT AS Suite # STORE #: 3389 0 INDICATES UNLINED 12"X 8"O.D. SHEETMETAL DELIVERABLES: FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT AIR CURTAINS CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN RESPONSE TO B}': Date: r) 7PROJECT #: 15375-032 0 Co 12 X 8 1ST FIGURE = SIDE SHOWN PAYMENT. AIR CURTAINS, WHEN REQUIRED, SHALL BE FURNISHED BY OWNER WITH INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TEST o 2ND FIGURE= SIDE NOT SHOWN ISSUE DATE: 100/0 09.08.2017 RESULTS. 0 WINDOW UNIT FROM READY-ACCESS AND INSTALLED BY THE GENERAL DESIGN MANAGER: RYAN WONG aCONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR FOR LEED iO AP: SUZANNE SULLIVAN U` 12 X 8 INDICATED 14"X 10"O.D. SHEETMETAL W/ LOCATION OF POWER CONNECTION. L. CONSTRUCTION AND POST CONSTRUCTION TESTING: ADDITIONAL PRODUCTION DESIGNER: HEB 1"SOUNDLINER(U.N.0), 12"X 8" LD. NET TESTING MAY BE REQUIRED BY LEED AND OTHER PROCESSES THAT MAY OFFICE COPY CHECKED BY: TOM CONNER NATURAL GAS PIPING OCCUR OUT OF SEQUENCE WITH COMMISSIONING SERVICE. CONTRACTOR o PROVIDE NATURAL GAS PIPING FROM GAS COMPANY METER TO EACH SHALL CONDUCT. DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS 0 FLEXIBLE DUCT CONNECTION DIRECTED BY STARBUCKS CXA. Revision Schedule PIECE OF EQUIPMENT OR APPLIANCES IN ACCORDANCE WITH CODE AND SPECIFICATIONS. PRESSURE REGULATORS FOR MEDIUM PRESSURE (1.2 SYSTEMS SHALL BE VENTED TO THE OUTDOORS. PROVIDE PIPING M. CONTRACTOR SHALL PROVIDE A TRAINING PLAN FOR EACH TRADE Rev Date By Description N 1111,,„,',,''1,,,1,,,,,',,,,1',,,,,, FLEXIBLE DUCT SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM. (MECHANICAL, ELECTRICAL, PLUMBING, RENEWABLE SYSTEMS) FOR THE D CXA'S APPROVAL. THE TRAINING PLAN SHALL OUTLINE ALL THE TOPICS - NECK SIZE THAT ARE TO BE COVERED ALONG WITH THE TIME DURATION FOR EACH U 12” 0 BRACING AND ANCHORING TOPIC. IT SHALL ALSO INCLUDE THE INSTRUCTOR'S NAME, ALL MECHANICAL EQUIPMENT, FIXED OR FLEXIBLY MOUNTED, SHALL BE CD-1 400 DESIGN CFM (WHERE APPLICABLE) BRACED OR ANCHORED TO COMPLY WITH LOCAL CODES. QUALIFICATIONS AND COMPANY LOGO. DIFFUSER TYPE(REFER SCHEDULE) N. THE CONTRACTOR IS RESPONSIBLE FOR RECORDING ATTENDANCE FOR Q\ EACH TRAINING SESSION. COPIES OF THESE SHALL BE SUBMITTED TO SHEET TITLE: T THE CXA. MECHANICAL NOTES /,IO. CONTRACTOR SHALL SUBMIT O&M MANUALS FOR ALL PIECES OF Lilr l_-_, CEILING DIFFUSER (FLOW ARROWS ONLY IF AIR FLOW NOT EQUIPMENT AT LEAST 6 WEEKS IN ADVANCE OF THE TRAINING SESSIONS. SCALE:AS SHOWN r SYMMETRICAL) \ _ oN \ CEILING RETURN/EXHAUST GRILLE SHEET NUMBER: M-0001 HEATING, VENTILATING AND AIR CONDITIONING HEATING, VENTILATING AND AIR CONDITIONING HEATING, VENTILATING AND AIR CONDITIONING HEATING, VENTILATING AND AIR CONDITIONING 9E* SECTION 230516-EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230553-IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT ihr .. .. SECTION 233713- DIFFUSERS, REGISTERS,AND GRILLES SECTION 233113-METAL DUCTS 1.1 REQUIREMENTS 1.1 QUALITY ASSURANCE 1.1 PRODUCTS 1.1 MATERIALS A. PROVIDE FOR EXPANSION OF PIPING IN ACCORDANCE WITH INDUSTRY STANDARDS A. QUALITY STANDARD FOR PIPING IDENTIFICATION:ASME A13.1. A. SEE MECHANICAL SCHEDULE FOR SPECIFIC DIFFUSERS, REGISTERS,AND GRILLES. A. SINGLE-WALL RECTANGULAR DUCTS AND FITTINGS: COMPLY WITH SMACNA'S"HVAC AND GOOD INSTALLATION PRACTICES. B. DIFFUSERS: METAL CONSTRUCTION, EXCEPT USE ALUMINUM MATERIAL WHEN IN DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE" BASED ON INDICATED 1.2 PRODUCTS DAMP AREAS. STATIC-PRESSURE CLASS UNLESS OTHERWISE INDICATED. END OF SECTION 230516 A. EQUIPMENT LABELS: METAL. 1. RECTANGULAR AND SQUARE CEILING DIFFUSERS, FIXED POSITION. B. SINGLE-WALL ROUND[AND FLAT-OVAL] DUCTS AND FITTINGS: COMPLY WITH B. WARNING SIGNS AND LABELS: 1/16 INCH (1.6 MM)THICK WITH FASTENERS. LETTER 3. LOUVER FACE DIFFUSERS. SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE", SIZE NOT LESS THAN 1/4 INCH (6.4 MM) FOR NAME OF UNITS IF VIEWING DISTANCE IS 4. LINEAR BAR DIFFUSERS WITH NARROW CORE SPACING ARRANGEMENT. CHAPTER 3, "ROUND, OVAL,AND FLEXIBLE DUCT', BASED ON INDICATED STATIC- LESS THAN 24 INCHES (600 MM), 1/2 INCH (13 MM) FOR VIEWING DISTANCES UP TO 72 5. LINEAR SLOT DIFFUSERS. PRESSURE CLASS UNLESS OTHERWISE INDICATED. SPIRAL ROUND OR SPIRAL OVAL HEATING, VENTILATING AND AIR CONDITIONING INCHES (1830 MM),AND PROPORTIONATELY LARGER LETTERING FOR GREATER C. REGISTERS AND GRILLES: METAL CONSTRUCTION, EXCEPT USE ALUMINUM DUCTS SHALL BE USED WHERE EXPOSED. ©2017 STARBUCKS COFFEE COMPANY VIEWING DISTANCES. INCLUDE SECONDARY LETTERING TWO-THIRDS TO THREE- MATERIAL WHEN IN DAMP AREAS. C. SHEET METAL MATERIALS: i SECTION 230517-SLEEVES AND SLEEVE SEALS FOR HVAC PIPING QUARTERS THE SIZE OF PRINCIPAL LETTERING.LABELS: 1. ADJUSTABLE BAR REGISTERS AND GRILLES. 1. GALVANIZED SHEET STEEL. STARBUCKS COFFEE C. PIPE PRETENSIONED. 2. FIXED FACE REGISTERS. 2. FINISHES FOR SURFACES EXPOSED TO VIEW: MILL PHOSPHATIZED. 1.1 SLEEVE-SEAL SYSTEMS D. DUCT LABELS: 1/16 INCH (1.6 MM)THICK WITH FASTENERS. LETTER SIZE NOT LESS A. FIELD-ASSEMBLED, MODULAR SEALING-ELEMENT UNIT FOR FILLING ANNULAR SPACE THAN 1/4 INCH (6.4 MM) FOR NAME OF UNITS IF VIEWING DISTANCE IS LESS THAN 24 D. EXTERIOR LOUVERS: D. DUCT LINER: COMPANY BETWEEN PIPING AND SLEEVE. INCHES (600 MM), 1/2 INCH (13 MM) FOR VIEWING DISTANCES UP TO 72 INCHES (1830 1. WEATHERPROOF, RAINPROOF DESIGN. 1. FIBROUS GLASS, TYPE I, FLEXIBLE. 1. SEALING ELEMENTS: EPDM RUBBER. MM),AND PROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING 2. FRAME STYLE SHALL BE COMPATIBLE WITH THE EXTERIOR FINISH OF BUILDING a. WATER-BASED LINER ADHESIVE:VOC CONTENT OF 80 G/L OR LESS FOR 2401 UTAH AVENUE SOUTH 2. PRESSURE PLATES: CARBON STEEL. DISTANCES. INCLUDE SECONDARY LETTERING TWO-THIRDS TO THREE-QUARTERS AND WALL CONSTRUCTION. INTERIOR APPLICATIONS. SEATTLE, WASHINGTON 98134 3 3. CONNECTING BOLTS AND NUTS: CARBON STEEL WITH CORROSION-RESISTANT THE SIZE OF PRINCIPAL LETTERING. . DRAINABLE BLADE CONSTRUCTION. 2. FLEXIBLE FIBER. MERIC. (206) 318-1575 COATING. E. STENCILS:ALUMINUM. 4. CAULK SLOTS. 3. NATURAL FIBER. 5. GALVANIZED REMOVABLE BIRD SCREEN. E. SEALANT MATERIALS: F. VALVE TAGS: BRASS, 0.032-INCH (0.8-MM) MINIMUM THICKNESS. THESE DRAWINGS AND SPECIFICATIONS ARE 1.2 SLEEVE-SEAL FITTINGS 6. COORDINATE FINISH WITH ARCHITECT. 1. TWO-PART TAPE SEALING SYSTEM: VOC CONTENT OF 250 G/L OR LESS FOR G. WARNING TAGS: 3 BY 5-1/4 INCHES (75 BY 133 MM) MINIMUM; BRASS GROMMET AND CONFIDENTIAL AND SHALL REMAIN THE SOLE A. MANUFACTURED PLASTIC, SLEEVE-TYPE, PLASTIC OR RUBBER WATERSTOP WIRE FASTENERS. INTERIOR APPLICATIONS. PROPERTY OF STARBUCKS CORPORATION, ASSEMBLY MADE FOR IMBEDDING IN CONCRETE SLAB OR WALL. H. THERMOSTAT LABELS: 1/8" (3MM) HIGH WHITE LETTERS ON KELLY GREEN OR END OF SECTION 233713 2. WATER-BASED JOINT AND SEAM SEALANT:VOC CONTENT OF 250 G/L OR WHICH IS THE OWNER OF THE COPYRIGHT IN BLACK PHENOLIC BACKGROUND(E.Q. "AC-1:WORKROOM"). LESS FOR INTERIOR APPLICATIONS. THIS WORK. THEY SHALL NOT BE 1.3 GROUT 3. FLANGED JOINT SEALANT:VOC CONTENT OF 250 G/L OR LESS FOR INTERIOR REPRODUCED (IN WHOLE OR IN PART), SHARED A. NONSHRINK, FACTORY PACKAGED. APPLICATIONS. END OF SECTION 230553 HEATING, VENTILATING AND AIR CONDITIONING 4. FLANGE GASKETS. WITH THIRD PARTIES OR USED IN ANY MANNER ON OTHER PROJECTSOR EXTENSIONS TO THIS 1.4 SLEEVE AND SLEEVE-SEAL SCHEDULE 5. ROUND DUCT JOINT 0-RING SEALS. PROJECT WITHOUT THE PRIOR WRITTEN A. EXTERIOR CONCRETE WALLS ABOVE GRADE: SECTION 238126-SPLIT-SYSTEM AIR-CONDITIONERS CONSENT OF STARBUCKS CORPORATION. 1. PIPING SMALLER THAN [NPS 6 (DN 150)]GALVANIZED-STEEL-PIPE 1.2 SEISMIC-RESTRAINT DEVICES 1.1 COMPONENTS INTENDED TO EXPRESS DESIGN INTENT FOR SLEEVES. HEATING, VENTILATING AND AIR CONDITIONING A. CONCEALED EVAPORATOR-FAN COMPONENTS: A. CHANNEL SUPPORT SYSTEM. INTENDED TO EXPRESS DESIGN INTENT FORA B. GALVANIZED-STEEL RESTRAINT CABLES. PROTOTYPICAL STARBUCKS STORE SECTION 230593-TESTING,ADJUSTING,AND BALANCING FOR HVAC 1. GALVANIZED-STEEL CHASSIS AND DRAIN PAN. C. HANGER ROD STIFFENER: STEEL TUBE OR STEEL SLOTTED-SUPPORT-SYSTEM (WHICH IS END OF SECTION 230517 2. INSULATED. SLEEVE WITH INTERNALLY BOLTED CONNECTIONS TO HANGER ROD. SUBJECT TO CHANGE AT ANYTIME)AND DO 1.1 SUMMARY 3. COPPER-TUBE REFRIGERANT COIL. NOT REFLECT ACTUAL SITE CONDITIONS. A. TAB FOR THE FOLLOWING: 4. ELECTRIC HEATING COIL. 1.3 DUCT CLEANING NEITHER PARTY SHALL HAVE ANY OBLIGATION 1. BALANCING AIR SYSTEMS: 5. FORWARD-CURVED GALVANIZED FAN. NOR LIABILITY TO THE OTHER(EXCEPT STATED A. CLEAN NEW AND EXISTING DUCT SYSTEM(S) BEFORE TESTING,ADJUSTING,AND a. CONSTANT-VOLUME AIR SYSTEMS. 6. MULTISPEED MOTOR. ABOVE) UNTIL A WRITTEN AGREEMENT IS HEATING, VENTILATING AND AIR CONDITIONING b. DUAL-DUCT SYSTEMS. 7. PERMANENT FILTERS. BALANCING. FULLY EXECUTED BY BOTH PARTIES. B C. VARIABLE-AIR-VOLUME SYSTEMS. B. FLOOR-MOUNTED, EVAPORATOR-FAN COMPONENTS: B. CLEAN THE FOLLOWING ITEMS: 1. AIR OUTLETS AND INLETS. R SECTION 230519-METERS AND GAGES FOR HVAC PIPING d. MULTIZONE SYSTEMS. 1. ENAMELED-STEEL CABINET WITH DISCHARGE GRILLE. STARBUCKS TEMPLATE VERSION i2017.05.18 e. INDUCTION-UNIT SYSTEMS. 2. INSULATED. 2. SUPPLY, RETURN,AND EXHAUST FANS. 1.1 PRODUCTS 3. AIR-HANDLING UNITS. A. LIQUID-IN-GLASS THERMOMETERS: 2. TAB EQUIPMENT: 3. COPPER-TUBE REFRIGERANT COIL. 4. COILS AND RELATED COMPONENTS. ED PROF 1. LIQUID-IN-GLASS THERMOMETERS: a. HEAT EXCHANGERS. 4. ELECTRIC HEATING COIL. 5. RETURN-AIR DUCTS, DAMPERS,ACTUATORS,AND TURNING VANES. SER Fss"/ a. CASE: CAST COMPACT-STYLE, LUMIN-IN-G 6-INCH (152-MM)SIZE. b. MOTORS. 5. CENTRIFUGAL FAN. .5 GI N EF O 6. SUPPLY-AIR DUCTS, DAMPERS,ACTUATORS,AND TURNING VANES. v R • 2 b. CASE FORM: BACK ANGLE. c. CONDENSING UNITS. 6. MULTISPEED MOTOR. v, v 7. DEDICATED EXHAUST AND VENTILATION COMPONENTS AND MAKEUP AIR - c. TUBE: GLASS WITH MAGNIFYING LENS AND BLUE ORGANIC LIQUID. d. HEAT-TRANSFER COILS. 7. DISPOSABLE FILTERS. 89/6A08PE SYSTEMS. /V 3. TAB EXISTING SYSTEMS AND EQUIPMENT. C. WALL-OR CEILING-MOUNTED, EVAPORATOR-FAN COMPONENTS: d. TUBE BACKGROUND: NONREFLECTIVE ALUMINUM WITH ETCHED SCALE IN 4. SOUND TESTS. 1. ENAMELED-STEEL CABINET. DEG F(DEG C). 1.4 DUCT SCHEDULE B. DUCT-THERMOMETER MOUNTING BRACKETS: FLANGED BRACKET, FOR 5. VIBRATION TESTS. 2. COPPER-TUBE REFRIGERANT COIL. ' OREGON Of I/. y irl 7 6. DUCT LEAKAGE TESTS. 3. ELECTRIC HEATING COIL. A. ALL DUCTS SHALL BE GALVANIZED STEEL. C. THERMOWELLS: �p `sfp 9 200 1. MATERIAL FOR USE WITH COPPER TUBING: CNR. 7. CONTROL SYSTEM VERIFICATION. 5. MULTIS4. PEED MOTOR. 1.5 HANGERS AND SUPPORT 4t M W ''�`� 2. MATERIAL FOR USE WITH STEEL PIPING: CSA. A. HANGER RODS: ELECTROGALVANIZED,ALL-THREAD RODS OR GALVANIZED RODS ro 3. TYPE: STEPPED SHANK UNLESS STRAIGHT OR TAPERED SHANK IS INDICATED. 1.2 QUALITY ASSURANCE 6. DISPOSABLE FILTERS. WITH THREADS PAINTED WITH ZINC-CHROMATE PRIMER AFTER INSTALLATION. U 4. HEAT-TRANSFER MEDIUM: MIXTURE OF GRAPHITE AND GLYCERIN. A. ASHRAE COMPLIANCE:APPLICABLE REQUIREMENTS IN ASHRAE 62.1, D. AIR-COOLED, COMPRESSOR-CONDENSER COMPONENTS: B. STRAP AND ROD SIZES: COMPLY WITH SMACNA'S"HVAC DUCT CONSTRUCTION _ EXPliiES: SECTION 7.2.2-"AIR BALANCING." 1. ENAMELED-STEEL CASING. STANDARDS- METAL AND FLEXIBLE,"TABLE 5-1 (TABLE 5-1 M), "RECTANGULAR DUCT D. PRESSURE GAGES: B. ASHRAE/IESNA COMPLIANCE:APPLICABLE REQUIREMENTS IN 2. HERMETICALLY SEALED SCROLL COMPRESSOR. HANGERS MINIMUM SIZE,"AND TABLE 5-2, "MINIMUM HANGER SIZES FOR ROUND a 1. DIRECT-MOUNTED, METAL-CASE, DIAL-TYPE PRESSURE GAGES: ASHRAEJIESNA 90.1, SECTION 6.7.2.3-"SYSTEM BALANCING." 3. COPPER-TUBE REFRIGERANT COIL. DUCT."a. CASE: LIQUID-FILLED SEALED DIAL- ); CAST ALUMINUM OR 4. HEAT-PUMP COMPONENTS. C. STEEL CABLES FOR GALVANIZED-STEEL DUCTS: GALVANIZED STEEL COMPLYING DRAWN STEEL;4-1/2-INCH (114-MM) DIAMETER. 1.3 EXECUTION 5. ALUMINUM-PROPELLER FAN. WITH ASTM A 603. b. PRESSURE-ELEMENT ASSEMBLY: BOURDON TUBE UNLESS OTHERWISE A. TOLERANCES: PLUS OR MINUS 10 PERCENT OF DESIGN VALUES. E. ACCESSORIES: LOW-VOLTAGE THERMOSTAT REFRIGERANT LINE KITS. D. STEEL CABLE END CONNECTIONS: CADMIUM-PLATED STEEL ASSEMBLIES WITH GPD Engineering and Architecture INDICATED. B. FINAL REPORT: PREPARE A CERTIFIED WRITTEN REPORT;TABULATE AND DIVIDE BRACKETS, SWIVEL,AND BOLTS DESIGNED FOR DUCT HANGER SERVICE; WITH AN Professional Corporation c. PRESSURE CONNECTION: BRASS, WITH NPS 1/4(DN 8),ASME B1.20.1 PIPE THE REPORT INTO SEPARATE SECTIONS FOR TESTED SYSTEMS AND BALANCED END OF SECTION 238126 AUTOMATIC-LOCKING AND CLAMPING DEVICE. 520 SOUTH MAIN ST. SUITE 2531 THREADS AND BOTTOM-OUTLET TYPE UNLESS BACK-OUTLET TYPE IS SYSTEMS. INCLUDE THE FOLLOWING: E. DUCT ATTACHMENTS: SHEET METAL SCREWS, BLIND RIVETS, OR SELF-TAPPING AKRON, OH 44311 1. GENERAL PROJECT DATA INDICATED. METAL SCREWS; COMPATIBLE WITH DUCT MATERIALS. P: 330.572.2100 F: 330.572.2101 d. DIAL: NONREFLECTIVE ALUMINUM WITH ETCHED SCALE IN PSI (KPA). 2. SYSTEM DIAGRAMS HEATING, VENTILATING AND AIR CONDITIONING F. TRAPEZE AND RISER SUPPORTS: e. WINDOW: GLASS. 3. AIR-HANDLING-UNIT TEST REPORTS 1. SUPPORTS FOR GALVANIZED-STEEL DUCTS: GALVANIZED-STEEL SHAPES AND GPD PROJECT NO: 2016355.37 f. RING: METAL. 4. APPARATUS-COIL TEST REPORTS SECTION 232300- REFRIGERANT PIPING PLATES. g. ACCURACY: GRADE A, PLUS OR MINUS 1 PERCENT OF MIDDLE HALF OF 5. FAN TEST REPORTS 2. SUPPORTS FOR STAINLESS-STEEL DUCTS: STAINLESS-STEEL SHAPES AND 6. DUCT TRAVERSE REPORTS 1.1 PERFORMANCE REQUIREMENTS SCALE RANGE. PLATES. 7. INSTRUMENT CALIBRATION REPORTS A. QUALITY STANDARDS:ASHRAE 15 AND ASME B31.5. E. GAGE ATTACHMENTS: 3. SUPPORTS FOR ALUMINUM DUCTS:ALUMINUM OR GALVANIZED STEEL COATED 2 1. SNUBBERS: BRASS; WITH NPS 1/4(DN 8-TYPE SURGE-DAMPENING DEVICE. C. INSPECTIONS: RANDOM CHECKS BY CONSTRUCTION MANAGER TO VERIFY B. LINE TEST PRESSURE FOR REFRIGERANT R-410A: WITH ZINC CHROMATE. ai INCLUDE EXTENSION FOR USE ON INSULATED PIPING. FINAL TAB REPORT. 1. SUCTION LINES FOR AIR-CONDITIONING APPLICATIONS: 300 PSIG (2068 KPA). v 2. SIPHONS: LOOP-SHAPED SECTION OF BRASS PIPE WITH NPS 1/4(DN 8) PIPE 2. SUCTION LINES FOR HEAT-PUMP APPLICATIONS: 535 PSIG (3689 KPA). END OF SECTION 233113 .`c THREADS. END OF SECTION 230593 3. HOT-GAS AND LIQUID LINES: 535 PSIG (3689 KPA). 3. VALVES: BRASS BALL, WITH NPS 1/4 (DN 8), PIPE THREADS. 1.2 PRODUCTS CC A. COPPER TUBE AND FITTINGS: TYPE K OR L(TYPE A OR B). Q END OF SECTION 230519 B. TIN-BRONZE BELLOWS, FLEXIBLE CONNECTORS. I- I HEATING, VENTILATING AND AIR CONDITIONING C. VALVES AND SPECIALTIES: 00 1. DIAPHRAGM PACKLESS VALVES. Net ft HEATING, VENTILATING AND AIR CONDITIONING SECTION 233423-HVAC POWER VENTILATORS 2. PACKED-ANGLE VALVES. O 3. CHECK VALVES. 06 1.1 QUALITY ASSURANCE 4. SERVICE VALVES. U M SECTION 233300-AIR DUCT ACCESSORIES A. AMCA-CERTIFIED RATINGS SEAL. 1.1 QUALITY ASSURANCE 5. SOLENOID VALVES: 24-V AC. A. INSTALLATION STANDARDS: NFPA 90A, NFPA 90B,AND SMACNA'S"HVAC DUCT 1.2 CEILING-MOUNTED VENTILATORS 7. SAFETYF VALVES. i 7. THERMOSTATIC EXPANSION VALVES FOR 40 DEG F (4.4 DEG C) SUCTION LL_ CN a CONSTRUCTION STANDARDS-METAL AND FLEXIBLE." A. HOUSING: STEEL WITH ACOUSTICAL INSULATION. TEMPERATURE;ADJUSTABLE SUPERHEAT. - N- E B. MOTORIZED AND NON-MOTORIZED DAMPERS USED FOR OUTSIDE AIR INTAKES, B. GRILLE: PLASTIC, LOUVERED. 8. HOT-GAS BYPASS VALVES WITH INTERNAL EQUALIZER,24-V AC, SET PRESSURE. I U m EXHAUST AND PRESSURE RELIEF(INCLUDING THOSE WITHIN PACKAGED HVAC C. ACCESSORIES: 9. STRAIGHT-TYPE STRAINERS. w Q 0- EQUIPMENT) SHALL HAVE A MAXIMUM AIR LEAKAGE VALUE PER THE ENERGY 1. VARIABLE-SPEED CONTROLLER. UJ o C".! CODE OR ASHRAE 90.1 WHEN TESTED PER AMCA STD. 500. 2. MANUAL STARTER SWITCH. 10.1MOISTURE/LIQUIDTYPE STRAINERS.I N ICA tjj 0 0 cr) 3. TIME-DELAY SWITCH. 11. INDICATORS. < - O > O 0 12. REPLACEABLE-CORE FILTER DRYERS WITH ACTIVATED ALUMINA MEDIA, Q O to 1.2 PRODUCTS 4. MOTION SENSOR. 2-PSIG (14-KPA) MAXIMUM PRESSURE LOSS. Z V-. Q (n N- A. BACKDRAFT AND PRESSURE RELIEF DAMPERS: MULTIPLE BLADE, PARALLEL ACTION, 5. CEILING RADIATION DAMPER. 13. PERMANENT FILTER DRYERS WITH ACTIVATED ALUMINA MEDIA, ~ ~ co to GRAVITY BALANCED WITH RETURN SPRINGS. 6. WASHABLE FILTER. U r , 0 r It 2-PSIG (14-KPA)MAXIMUM PRESSURE LOSS. W0 W B. BAROMETRIC RELIEF DAMPERS: HORIZONTAL OR VERTICAL MOUNTING; MULTIPLE 7. VIBRATION ISOLATORS. 14. MUFFLERS. -� - 0 Q "in BLADE, PARALLEL ACTION, GRAVITY BALANCED WITH RETURN SPRINGS. 8. ROOF JACK OR WALL CAP AND TRANSITION FITTINGS. O O r' 0 15. RECEIVERS. C. MANUAL VOLUME DAMPERS: MULTIPLE BLADE, PARALLEL-BLADE DESIGN, WITH 16. LIQUID ACCUMULATORS. CC 0_ E LINKAGE OUTSIDE AIRSTREAM. END OF SECTION 233423 d D 1. STANDARD, STEEL, MANUAL VOLUME DAMPERS. 0 2. STANDARD,ALUMINUM, MANUAL VOLUME DAMPERS. 1.3 REFRIGERANTS 389 0 3. LOW-LEAK, STEEL, MANUAL VOLUME DAMPERS. A. R 410A. STORE #: PROJECT #: 15375-032 2 O 4. LOW-LEAK,ALUMINUM, MANUAL VOLUME DAMPERS. 1.4 PIPING APPLICATION SCHEDULES U D. CONTROL DAMPERS: [PARALLEL] [OPPOSED]-BLADE DESIGN; GALVANIZED-STEEL A. PIPING APPLICATIONS FOR REFRIGERANT R-410A: MAXIMUM NPS 4 (DN 100). ISSUE DATE: 100%0% 09.0 09.08.2017 FRAME AND BLADES. a. 1. SUCTION LINES FOR CONVENTIONAL AIR-CONDITIONING APPLICATIONS: DESIGN MANAGER: RYAN WONG E. CEILING RADIATION DAMPERS: REPLACEABLE HEAT-RESPONSIVE DEVICE. O COPPER. LEED®AP: SUZANNE SULLIVAN F. FLANGE CONNECTIONS. 2. HOT-GAS AND LIQUID LINES, [AND SUCTION LINES FOR HEAT-PUMP PRODUCTION DESIGNER: HEB 92 G. TURNING VANES: SINGLE-BLADE, GALVANIZED SHEET STEEL. APPLICATIONS]: CHECKED BY: TOM CONNER 1✓ H. REMOTE DAMPER OPERATORS. _ c0i I. DUCT-MOUNTED ACCESS DOORS: DOUBLE WALL, RECTANGULAR, GALVANIZED a. NPS 2 (DN 50)AND SMALLER: COPPER WITH BRAZED JOINTS. ( SHEET STEEL WITH INSULATION. 3. SAFETY-RELIEF-VALVE DISCHARGE PIPING: Revision Schedule ) i HEATING, VENTILATING AND AIR CONDITIONING HEATING, VENTILATING AND AIR CONDITIONING *tee SECTION 233300-AIR DUCT ACCESSORIES SECTION 230800-COMMISSIONING OF HVAC ,hir -; 141L. 1.1 QUALITY ASSURANCE 1.1 COMPONENTS A. INSTALLATION STANDARDS: NFPA 90A, NFPA 90B,AND SMACNA'S "HVAC DUCT A. CONCEALED EVAPORATOR-FAN COMPONENTS: CONSTRUCTION STANDARDS- METAL AND FLEXIBLE." 1. GALVANIZED-STEEL CHASSIS AND DRAIN PAN. B. MOTORIZED AND NON-MOTORIZED DAMPERS USED FOR OUTSIDE AIR INTAKES, 2. INSULATED. EXHAUST AND PRESSURE RELIEF(INCLUDING THOSE WITHIN PACKAGED HVAC 3. COPPER-TUBE REFRIGERANT COIL. EQUIPMENT) SHALL HAVE A MAXIMUM AIR LEAKAGE VALUE PER THE ENERGY 4. ELECTRIC HEATING COIL. CODE OR ASHRAE 90.1 WHEN TESTED PER AMCA STD. 500. 5. FORWARD-CURVED GALVANIZED FAN. 6. MULTISPEED MOTOR. ©2017 STARBUCKS COFFEE COMPANY 1.2 PRODUCTS 7. PERMANENT FILTERS. A. BACKDRAFT AND PRESSURE RELIEF DAMPERS: MULTIPLE BLADE, PARALLEL ACTION, B. FLOOR-MOUNTED, EVAPORATOR-FAN COMPONENTS: GRAVITY BALANCED WITH RETURN SPRINGS. 1. ENAMELED B. BAROMETRIC RELIEF DAMPERS: HORIZONTAL OR VERTICAL MOUNTING; MULTIPLE 2. INSULATED-STEEL CABINET WITH DISCHARGE GRILLE. STARBUCKS COFFEE BLADE, PARALLEL ACTION, GRAVITY BALANCED WITH RETURN SPRINGS. 3. COPPER-TUBE REFRIGERANT COIL. COMPANY C. MANUAL VOLUME DAMPERS: MULTIPLE BLADE,PARALLEL-BLADE DESIGN,WITH 4. ELECTRIC HEATING COIL. LINKAGE OUTSIDE AIRSTREAM. 5. CENTRIFUGAL FAN. 2401 UTAH AVENUE SOUTH 1. STANDARD, STEEL, MANUAL VOLUME DAMPERS. 6. MULTISPEED MOTOR. SEATTLE, WASHINGTON 98134 2. STANDARD, ALUMINUM, MANUAL VOLUME DAMPERS. 7. DISPOSABLE FILTERS. (206) 318-1575 3. LOW-LEAK, STEEL, MANUAL VOLUME DAMPERS. C. WALL-OR CEILING-MOUNTED, EVAPORATOR-FAN COMPONENTS: --- 4. LOW-LEAK,ALUMINUM, MANUAL VOLUME DAMPERS. 1. ENAMELED-STEEL CABINET. THESE DRAWINGS AND SPECIFICATIONS ARE D. CONTROL DAMPERS: [PARALLEL] [OPPOSED]-BLADE DESIGN; GALVANIZED-STEEL 2. COPPER-TUBE REFRIGERANT COIL. CONFIDENTIAL AND SHALL REMAIN THE SOLE FRAME AND BLADES. 3. ELECTRIC HEATING COIL. PROPERTY OF STARBUCKS CORPORATION, E. CEILING RADIATION DAMPERS: REPLACEABLE HEAT-RESPONSIVE DEVICE. 4. CENTRIFUGAL FAN. WHICH IS THE OWNER OF THE COPYRIGHT IN F. FLANGE CONNECTIONS. 5. MULTISPEED MOTOR. THIS WORK. THEY SHALL NOT BE G. TURNING VANES: SINGLE-BLADE, GALVANIZED SHEET STEEL. 6. DISPOSABLE FILTERS. REPRODUCED (IN WHOLE OR IN PART), SHARED H. REMOTE DAMPER OPERATORS. D. AIR-COOLED, COMPRESSOR-CONDENSER COMPONENTS: WITH THIRD PARTIES OR USED IN ANY MANNER I. DUCT-MOUNTED ACCESS DOORS: DOUBLE WALL, RECTANGULAR, GALVANIZED 1. ENAMELED-STEEL CASING. ON OTHER PROJECTS OR EXTENSIONS TO THIS SHEET STEEL WITH INSULATION. 2. HERMETICALLY SEALED SCROLL COMPRESSOR. PROJECT WITHOUT THE PRIOR WRITTEN J. PRESSURE RELIEF ACCESS DOORS: SINGLE WALL. 3. COPPER-TUBE REFRIGERANT COIL. CONSENT OF STARBUCKS CORPORATION. K. FLEXIBLE CONNECTORS: INDOOR AND OUTDOOR, HIGH TEMPERATURE. 4. HEAT-PUMP COMPONENTS. THESE DRAWINGS AND SPECIFICATIONS ARE Q. FLEXIBLE DUCTS: INSULATED. 5. ALUMINUM-PROPELLER FAN. INTENDED TO EXPRESS DESIGN INTENT FOR A R. DUCT SECURITY BARS. E. ACCESSORIES: LOW-VOLTAGE THERMOSTAT REFRIGERANT LINE KITS. PROTOTYPICAL STARBUCKS STORE (WHICH IS S. DUCT ACCESSORY HARDWARE. END OF SECTION 238126 SUBJECT TO CHANGE AT ANYTIME)AND DO END OF SECTION 233300 NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER(EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS HEATING, VENTILATING AND AIR CONDITIONING FULLY EXECUTED BY BOTH PARTIES. HEATING, VENTILATING AND AIR CONDITIONING SECTION 233113-METAL DUCTS STARBUCKS TEMPLATE VERSION 12017.05.18 SECTION 233423-HVAC POWER VENTILATORS 1.1 MATERIALS 1.1 QUALITY ASSURANCE A. SINGLE-WALL RECTANGULAR DUCTS AND FITTINGS: COMPLY WITH SMACNA'S"HVAC Eo PROF A. AMCA-CERTIFIED RATINGS SEAL. DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE" BASED ON ��R es INDICATED STATIC-PRESSURE CLASS UNLESS OTHERWISE INDICATED. 5 GIN[ p 1.2 CEILING-MOUNTED VENTILATORS B. SINGLE-WALL ROUND[AND FLAT-OVAL] DUCTS AND FITTINGS: COMPLY WITH CO� FR A. HOUSING: STEEL WITH ACOUSTICAL INSULATION. SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE", it- / 1 ` B. GRILLE: PLASTIC, LOUVERED. CHAPTER 3, "ROUND, OVAL,AND FLEXIBLE DUCT', BASED ON INDICATED STATIC- ' 6 V "� j ' 'i//7 C. ACCESSORIES: PRESSURE CLASS UNLESS OTHERWISE INDICATED. SPIRAL ROUND OR SPIRAL `, 1. VARIABLE-SPEED CONTROLLER. OVAL DUCTS SHALL BE USED WHERE EXPOSED. OREGON 2. MANUAL STARTER SWITCH. C. SHEET METAL MATERIALS: S p 3. TIME-DELAY SWITCH. 1. GALVANIZED SHEET STEEL. se FP g 201 \� 4. MOTION SENSOR. 2. FINISHES FOR SURFACES EXPOSED TO VIEW: MILL PHOSPHATIZED. 'er,--.`VA/Mck .WIN rot 5. CEILING RADIATION DAMPER. D. DUCT LINER: a 10 6. WASHABLE FILTER. 1. FIBROUS GLASS, TYPE I, FLEXIBLE. 7. VIBRATION ISOLATORS. a. WATER-BASED LINER ADHESIVE:VOC CONTENT OF 80 G/L OR LESS FOR EXPIRES: As 8. ROOF JACK OR WALL CAP AND TRANSITION FITTINGS. INTERIOR APPLICATIONS. 2. NATURLEAL FIBER. RIC. /'._ END OF SECTION 233423 3. NATURAL FIBER. E. SEALANT MATERIALS: GPD Engineering and Architecture 1. TWO-PART TAPE SEALING SYSTEM:VOC CONTENT OF 250 G/L OR LESS FOR Professional Corporation INTERIOR APPLICATIONS. 2. WATER-BASED JOINT AND SEAM SEALANT:VOC CONTENT OF 250 G/L OR 520 SOUTH MAIN ST. SUITE 2531 HEATING, VENTILATING AND AIR CONDITIONING LESS FOR INTERIOR APPLICATIONS. AKRON, OH 44311 3. FLANGED JOINT SEALANT:VOC CONTENT OF 250 G/L OR LESS FOR INTERIOR P: 330.572.2100 F: 330.572.2101 SECTION 233713-DIFFUSERS, REGISTERS,AND GRILLES APPLICATIONS. GPD PROJECT NO: 2016355.37 1.1 PRODUCTS 4. FLANGE GASKETS. A. SEE MECHANICAL SCHEDULE FOR SPECIFIC DIFFUSERS, REGISTERS,AND GRILLES. 5. ROUND DUCT JOINT 0-RING SEALS. B. DIFFUSERS: METAL CONSTRUCTION, EXCEPT USE ALUMINUM MATERIAL WHEN IN 1.2 SEISMIC-RESTRAINT DEVICES DAMP AREAS. A. CHANNEL SUPPORT SYSTEM. 1. RECTANGULAR AND SQUARE CEILING DIFFUSERS, FIXED POSITION. B. GALVANIZED-STEEL RESTRAINT CABLES. ai 3. LOUVER FACE DIFFUSERS. C. HANGER ROD STIFFENER: STEEL TUBE OR STEEL SLOTTED-SUPPORT-SYSTEM U 4. LINEAR BAR DIFFUSERS WITH NARROW CORE SPACING ARRANGEMENT. SLEEVE WITH INTERNALLY BOLTED CONNECTIONS TO HANGER ROD. t 5. LINEAR SLOT DIFFUSERS. C. REGISTERS AND GRILLES: METAL CONSTRUCTION, EXCEPT USE ALUMINUM MATERIAL WHEN IN DAMP AREAS. 1.3 DUCT CLEANING I Q 1. ADJUSTABLE BAR REGISTERS AND GRILLES. A. CLEAN BALANC NG.W AND EXISTING DUCT SYSTEM(S) BEFORE TESTING,ADJUSTING,AND I- I 2. FIXED FACE REGISTERS. B. CLEAN THE FOLLOWING ITEMS: 00 Y D. EXTERIOR LOUVERS: 1. AIR OUTLETS AND INLETS. 1. WEATHERPROOF, RAINPROOF DESIGN. N- CC 2. FRAME STYLE SHALL BE COMPATIBLE WITH THE EXTERIOR FINISH OF BUILDING 2. SUPPLY, RETURN,AND EXHAUST FANS. 0 3. AIR-HANDLING UNITS. �( AND WALL CONSTRUCTION. 4. COILS AND RELATED COMPONENTS. W 3. DRAINABLE BLADE CONSTRUCTION. 5. RETURN-AIR DUCTS, DAMPERS,ACTUATORS,AND TURNING VANES. 4. CAULK SLOTS. U CO 5. GALVANIZED REMOVABLE BIRD SCREEN. 6. SUPPLY-AIR DUCTS, DAMPERS,ACTUATORS,AND TURNING VANES. N I 7. DEDICATED EXHAUST AND VENTILATION COMPONENTS AND MAKEUP AIR > LL N 06. COORDINATE FINISH WITH ARCHITECT. SYSTEMS. St: iii END OF SECTION 233713 U Cu 1.4 DUCT SCHEDULE < 0_ A. ALL DUCTS SHALL BE GALVANIZED STEEL. w n IE o 1.5 HANGERS AND SUPPORT Q - 0 > O r A. HANGER RODS: ELECTROGALVANIZED,ALL-THREAD RODS OR GALVANIZED RODS Z (n 0 WITH THREADS PAINTED WITH ZINC-CHROMATE PRIMER AFTER 0 0 in INSTALLATION. O Q r B. STRAP AND ROD SIZES: COMPLY WITH SMACNA'S"HVAC DUCT CONSTRUCTION 5 in STANDARDS-METAL AND FLEXIBLE,"TABLE 5-1 (TABLE 5-1M), "RECTANGULAR O Q^ 3 N- C� a)a) DUCT HANGERS MINIMUM SIZE,"AND TABLE 5-2, "MINIMUM HANGER SIZES FOR d 0.- a- r H E ROUND DUCT." QC. STEEL CABLES FOR GALVANIZED-STEEL DUCTS: GALVANIZED STEEL COMPLYING STORE #: 3389 WITH ASTM A 603. PROJECT #: 15375 032 O D. STEEL CABLE END CONNECTIONS: CADMIUM-PLATED STEEL ASSEMBLIES WITH BRACKETS, SWIVEL,AND BOLTS DESIGNED FOR DUCT HANGER SERVICE; WITH ISSUE DATE: 100%09.08.2017 0 AN AUTOMATIC-LOCKING AND CLAMPING DEVICE. DESIGN MANAGER: RYAN WONG Ur E. DUCT ATTACHMENTS: SHEET METAL SCREWS, BLIND RIVETS, OR SELF-TAPPING LEEDOAP: SUZANNE SULLIVAN METAL SCREWS; COMPATIBLE WITH DUCT MATERIALS. PRODUCTION DESIGNER: HEB N F. TRAPEZE AND RISER SUPPORTS: CHECKED BY: TOM CONNER 0 1. SUPPORTS FOR GALVANIZED-STEEL DUCTS: GALVANIZED-STEEL SHAPES AND v PLATES. ( 2. SUPPORTS FOR STAINLESS-STEEL DUCTS: STAINLESS-STEEL SHAPES AND Revision Schedule PLATES. a`) 3. SUPPORTS FOR ALUMINUM DUCTS:ALUMINUM OR GALVANIZED STEEL COATED Rev Date By Description Co WITH ZINC CHROMATE. D O END OF SECTION 233113 2 Q SHEET TITLE: N- r MECHANICAL OUTLINE SPECIFICATIONS SCALE:AS SHOWN NN- 0 CV SHEET NUMBER: V r CV M-0004 HVAC CONTROL NOTES MECHANICAL DESIGN PLAN NOTES 91** VENTILATION AIR CALCULATION (BASED ON THE 2014 OMSC WITH STATE AMENDMENTS AND ASHRAE STANDARD 62.1) NOTE: SEE OTHER GENERAL NOTES FOR ADDITIONAL REQUIREMENTS. A. SEE MECHANICAL SPECIFICATIONS FOR FURTHER ZONE OCCUPANCY ZONE OUTDOOR AIR OUTDOOR AIR ZONE AIR MINIMUM THE BELOW NOTES ARE NOTA COMPLETE SEQUENCE OF OPERATIONS, REQUIREMENTS. Abr ; AL MARK AREA SERVED OCCUPANCY AREA DENSITY POPULATION CFM PER CFM PER EFFECTIVNESS OUTDOOR AIR CO2 SENSORTO SETPOINT SHALL BE 1000ppm. CATEGORYB. SEE ARCHITECTURAL SHEETS FOR PAINTING AND (Pz) (p/1000 SF) (Pz) PERSON (Rp) SF(Ra) (Ez) (CFM) RTU-1 &RTU-2 COLORS OF ALL EXPOSED DUCTWORK, DIFFUSERS AND OCCUPIED MODE: GRILLES. RTU-2 BAR BAR-KITCHEN 573 100 3 7.5 0.18 0.8 158 1. FAN SHALL RUN CONTINUOUSLY WHILE BRINGING IN MINIMUM DCV GAS REQUIREMENTS: OUTSIDE AIR AS INDICATED. C. SEE ARCHITECTURAL SHEETS FOR DIMENSIONED WORKROOM OFFICE/STORAGE 476 5 2 5 0.12 0.8 84 SYSTEM IS SIZED FROM LOW PRESSURE 2. IF CO2 SENSOR SETPOINT IS EXCEEDED, OUTSIDE AIR DAMPERS DIFFUSER&EXPOSED DUCT LOCATIONS. GAS (10"W.C.AT 0.3"W.C. PRESSURE SHALL MODULATE TO MAXIMUM DCV OUTSIDE AIR INDICATED, ADDITIONAL DROP)OVERALL SYSTEM LENGTH OF ONCE CO2 LEVELS DROPS BELOW SETPOINT, OUTSIDE AIR DAMPER D. DIFFUSERS AND RETURN GRILLES SHALL BE CENTERED VENTILATION KITCHEN 200 - - - 0.7 0.8 175 100' SHALL RETURN TO MINIMUM DCV CFM. IN CEILING TILE, UNLESS OTHERWISE NOTED. ©2017 STARBUCKS COFFEE COMPANY (NOTE 3) RTU-1 = 120 MBH 3. 1ST STAGE HEATING SHALL BE FIRED. RTU-2= 120 MBH 4. 1ST STAGE COOLING SHALL BE ECONOMIZER AIR IF AIR CONDITIONS E. REFERENCE LANDLORD WORK LETTER FOR DIVISION OF TOTAL 417 WATER HEATER= 40 MBH ARE GOOD(OPERATION PER CODE). MECHANICAL SCOPE OF WORK AND COORDINATE WITH STARBUCKS COFFEE TOTAL= 280 MBH 5. 2ND STAGE COOLING SHALL BE MECHANICAL. STARBUCKS CONSTRUCTION MANAGER. ZONE OCCUPANCY ZONE OUTDOOR AIR OUTDOOR AIR ZONE AIR MINIMUM DCV MAXIMUM DCV COMPANY OCCUPANCY MARK AREA SERVED AREA DENSITY POPULATION CFM PER CFM PER EFFECTIVNESS OUTDOOR AIR OUTDOOR AIR UNOCCUPIED MODE: CATEGORY (Az) (P/1000 SF) (Pz) PERSON(Rp) SF(Ra) (Ez) (CFM) (CFM) 1. FAN SHALL CYCLE WITH HEATING/COOLING SECTION AND OUTSIDE SHEET NOTES 2401 UTAH AVENUE SOUTH AIR DAMPER SHALL BE CLOSED. SEATTLE, WASHINGTON 98134 RTU-1 SEATING FAST FOOD -DINING 1092 SEAT COUNT 56 7.5 0.18 0.8 246 771 2. HEATING AND COOLING SECTIONS SHALL CYCLE AS CALLED FOR 1. ROUTE 30"x16"SUPPLY AND RETURN DUCT UP THROUGH ROOF AND (206) 318-1575 BY THE THERMOSTAT. CONNECT TO RTU-1.TRANSITION TO FULL SIZE CONNECTIONS AT UNIT, TOTAL 246 771 THESE DRAWINGS AND SPECIFICATIONS ARE EF-1 PROVIDE WITH FLEXIBLE DUCT CONNECTION TO UNIT. REFER TO SHEET M-1102 FOR FURTHER INFORMATION. COORDINATE EXACT LOCATION CONFIDENTIAL AND SHALL REMAIN THE SOLE NOTES: 1. FAN SHALL COME ON DURING OCCUPIED TIME AND RUN PRIOR TO START OF ANY WORK. ENSURE SUPPLY AND RETURN DUCTS PROPERTY OF STARBUCKS CORPORATION, 1. SEATING ZONE POPULATION IS BASED UPON SEAT COUNT WITH WITH DIVERSITY. CONTINUOUSLY. PENETRATE ROOF BETWEEN TRUSSES AND THE OUTSIDE AIR INTAKE IS WHICH IS THE OWNER OF THE COPYRIGHT IN 2. HVAC UNITS SHALL BE BALANCED TO PROVIDE THE MINIMUM DCV OUTDOOR AIR QUANITIES INDICATED. 2. DURING UNOCCUPIED TIME, FAN SHALL BE OFF. LOCATED 15FT FROM ANY VENT. THIS WORK THEY SHALL NOT BE 3. ADDITIONAL VENTILATION IS REQUIRED FOR(1)WARMING OVEN AND(1)DISHWASHER. REPRODUCED(IN WHOLE OR IN PART), SHARED 4. MAXIMUM DCV VENTILATION AIR SHOWN SHALL BE CONTROLLED BY CO2 SENSOR(SEE OTHER CONTROL NOTES). LEED SPECIFIC REQUIREMENTS 2. ROUTE TTO SUPPLY-2.TANDRETURN DUCTUPTHROUGH ROOF AND WITH THIRD ROJPARTIES ORUSED N ANY TO IS CONNECT TO RTU-2.TRANSITION TO FULL SIZE CONNECTIONS AT UNIT, ON OTHER PROJECTS OR EXTENSIONS TO THIS PROVIDE WITH FLEXIBLE DUCT CONNECTION TO UNIT. REFER TO SHEET PROJECT WITHOUT THE PRIOR WRITTEN RESTROOM EXHAUST CALCULATION (BASED ON THE 2014 OMSC WITH STATE AMENDMENTS) 1. DUCT FRICTION LOSS SIZED AND SHALL BE INSTALLED TO 0.05 IN. M-1102 FOR FURTHER INFORMATION- COORDINATE EXACT LOCATION CONSENT OF STARBUCKS CORPORATION. PRIOR TO START OF ANY WORK. ENSURE SUPPLY AND RETURN DUCTS THESE DRAWINGS AND SPECIFICATIONS ARE W.C./100 FT. MAXIMUM. PENETRATE ROOF BETWEEN TRUSSES AND THE OUTSIDE AIR INTAKE IS INTENDED TO EXPRESS DESIGN INTENT FOR A MARK AREA SERVED NUMBER OF WATER CFM PER TOTAL MINIMUM PROPOSED LOCATED 15FT FROM ANY VENT. PROTOTYPICAL STARBUCKS STORE (WHICH IS CLOSETS/URINALS WC/UR EXHAUST CFM EXHAUST CFM 2. UNIT ECONOMIZER SHALL INCLUDE MOTORIZED DAMPER AS PART OF SUBJECT TO CHANGE AT ANYTIME)AND DO FACTORY INSTALLATION. 3. ROUTE 10110 EXHAUST DUCT UP THROUGH ROOF AND CONNECT TO EF- NOT REFLECT ACTUAL SITE CONDITIONS. EF-1 RESTROOMS 2 75 150 260 3. DUCT JOINTS SHALL BE SEALED IN ACCORDANCE WITH ASHRAE 90.1 1, TRANSITION TO FULL SIZE CONNECTIONS AT UNIT, REFER TO SHEET NEITHER PARTY SHALL HAVE ANY OBLIGATION CLASS B AND OREGON STATE ENERGY CODE. M-1102 FOR FURTHER INFORMATION. EXHAUST FAN SHALL RUN NOR LIABILITY TO THE OTHER(EXCEPT STATED CONTINUOUSLY WHEN STORE IS OCCUPIED AND SHALL TURN OFF ABOVE) UNTIL A WRITTEN AGREEMENT IS WHEN STORE IS NOT OCCUPIED, EXHAUST FAN CONTROL SHALL BE FULLY EXECUTED BY BOTH PARTIES. 4- ALL SUPPLY AND RETURN DUCTS SHALL BE INSULATED TO MINIMUM R- ACCOMPLISHED WITH LCP,COORDINATE WITH ELECTRICAL, SEE 8 WHICH MEETS CODE. SCHEDULE FOR SIZE. STARBUCKS 1 I -LATE VERSION 12017.05.18 M X0105 12"x12" 4. WALL MOUNTED THERMOSTAT FOR RTU-1 AND RTU-2 AT 48"A.F.F. Fss 130 THERMOSTAT SHALL BE 7-DAY PROGRAMMABLE WITH NIGHT �5 �G IN E F4 o2 o , .. . _. .... . . .. . . DIR v CONFIRM HEIGHT COMPLIES WITH BARRIER FREE,AND ALL THER LOCAL 896J§PE M X0101 , ; - _ . .• . . .- _ . . . - - - - x - - _ : REQUIREMENTS. MULTIPLE HERMOSTATS SHALL BE STACKED INA i /Vl- / '�7 10"m M"X0101 8"m 8"m VERTICAL CONFIGURATION WITH A MINIMUM OF 8"CLEARANCE BELOW OREGON / _ \ EACH THERMOSTAT, 290 T 290 M X0105 ` K gyp_ sF'P 9 20`' 5. REMOTE TEMPERATURE SENSOR AT 60"A.F.F ON WALL. "y _rr�. I_\ 12"x12" 414:01%4141.MPr- �_I! 1130 U 6. MANUAL BALANCING DAMPER(TYPICAL). DAMPERS SHALL NOT BE �II : m ® A INSTALLED AT THE GRILLE/NECK UNLESS SHOWN. EXPIRES: I3,(22 11 (y �_\ M X0103 0 M X0103 , �_� Y _ _ Jdl I _ r♦ 6"m 6"m == �I" cr-- �I 7. CO2 SENSOR LOCATED AT 60"A.F.F. ON WALL INTERLOCK WITH �� O v.-,> RESPECTIVE HVAC UNIT AND SEE M-0001 FOR FURTHER INFORMATION. �Md r., ® 9 75 O 75 COORDINATE CONTROLS WITH HVAC UNIT AND PROVIDE ADDITIONAL Art 10"e Ili,. 0 0 C.' G ,; a ; , f CONTROL COMPONENTS AS MAY BE NEEDED FOR A COMPLETE AND OPERATIONAL SYSTEM. M X0101 X0101 O M X0101 O I M X0101 M X0101 GPD Engineering and Architecture 10"m i•� ©10"mon i rr =__ 10"m 10"m 10"m 8. CO2 ALARM SHALL BE MOUNTED AT 60"A.F.F. NEXT TO MANAGER'S Professional Corporation 290 ,® I� '� ` (RTU-1) © STATION,COORDINATE WITH ELECTRICAL FOR POWER RECEPTACLE. 520 SOUTH MAIN ST. SUITE 2531 ® 290llk O' r� O 200 SE 200 200 A we ©X0111 0 ��� 41� 0 M& f 9, TYPE'13'FLUE VENT TO WATER HEATER, LOCATE A CODE MINIMUM AKRON, OH 44311 ® M X0110® -® I = = F DISTANCE AWAY FOR OUTSIDE AIR INTAKES AND PARAPET ON ROOF. P: 330.572.2100 F: 330.572.2101 0 II �� m m 8"m 12"m MINN* OFFSET VENT AS NEEDED. IF ADDITIONAL SEPARATION IS NEEDED, GPD PROJECT NO. 2016355 37 `1i, �7�4j .. K) ©X0109 O io m 1111MIN" EXTEND FLUE TO 3 FT.ABOVE INTAKE OR PER AHJ. M X0101 K - 8 m , ® I 10- PROVIDE AND INSTALL DUCT MOUNTED SMOKE DETECTOR IN RETURN frAfir10"m r :' i '- 20"x24" r - I AIR PLENUM. INTERLOCK SMOKE DETECTOR WITH RESPECTIVE RTU �alI12gp a� �.�.��. .. • _" na _ " p TO SHUT OWN UNIT UPON DETECTION OF SMOKE. COORDINATE WITH ��alt�inara ai �� ■ O - M X0101 ELECTRICAL AND SEE POWER SHEETS FOR FURTHER REQUIREMENTS I SD i� -- �� __ __ AND REMOTE ANNUNCIATOR. INTERCONNECT WITH CENTRAL SYSTEM IF ��_=ter iI, e .Thist i 1" 10"m _ I APPLICABLE. (SEE DETAIL). ^I N‘lir \ �I C 0 8"m 10"m 12'm 7- .4-I'', - U , % 1: M X0104 l M X0102 kV /Y.% 16"o 200 11. 3/4"GAS TO WATER HEATER WITH APPROVED GAS SHUT-OFF VALVE, lo. a (TYP. OF 14) 0 DIRT LEG,AND FLEXIBLE GAS CONNECTION. CO II M X0104 12. ROUTE 3/4"GAS LINE UP THROUGH ROOF. SEE ROOF PLAN FOR 03 r4 rap 0 AItt : Vim.._._-.24"x24" 24"x3" pH I zo tv 1500 164 �...� Y M X0101 ` 10"m 11 N - o r 10 CONTINUATION. CC ,280 _ 13- CARBON MONOXIDE SENSOR LOCATED AT 60"A.F.F. ON WALL O I -- -- - N • I M X0104 _ INTERLOCK WITH RESPECTIVE HVAC UNIT. COORDINATE CONTROLS X0104 i l ■� ■� U WITH HVAC UNIT AND PROVIDE ADDITIONAL CONTROL COMPONENTS AS 0 co al 8"m 10"m - 12"m 8"m 24"x24" E. aI MAYBE NEEDED FORA COMPLETE AND OPERATIONAL SYSTEM. N 2 M X0101 . `_1I (a 24"x24" O \ / ILa 16"m 1375 � N o 10"m , 1500 ® , ! 14. CARBON MONOXIDE ALARM SHALL BE MOUNTED AT 48"A.F.F. NEXT TO 0 N. ca 280 w j 'v I MANAGERS STATION. COORDINATE WITH ELECTRICAL FOR POWER I W QCD CL WA rit el-, lie eNc I RECEPTACLE. I.. CCrt LL CO -, , , _ __ o \ 74 111 ( -- :�� __====. - . . '� .,_- E 15. ROUTE DUCT THROUGH ROOF TRUSS.TYPICAL. Q 7 `� ' \ ``� SCOPE OF WORK SUMMARY N. tusi MECHANICAL z Q u7 11 (RTU-2) i. tiTa I I mos', �`\�o € V U r- 10"m n M X01 t 1 4 M X0106 8„m I 10"0 12"m A 10"m 1��00�° M X0101 ON. c 1 _-- 1 10"m ^ c- _ a0 _..... __.- -- _._ - . . ------- - -- ::-- D X0101 _- ----"- -- - - = = 0 _... _- --------- 200 _ THE FOLLOWING SCOPE OF WORK IS BASED ON THE LANDLORD'S d L.L 0_ r I- E I M X0108 O 10"0 I a WORKLETTER EXHIBIT C. THIS SCOPE OF WORK IS NOT INTENDED TO Q _ M X0107 O 280 O 0 0 0 0 ' - INDICATE THE FULL SCOPE, BUT ONLY A BROAD SUMMARY. THE GENERAL 0CONTRACTOR SHALL REFERENCE THE COMPLETE WORKLETTER FOR A STORE #: 3389 10"m - I . . MORE DETAILED DESCRIPTION OF WORK BY BOTH PARTIES. ANY 75 032 O /� 12"m - \ ♦ I 4. :„ ` QUESTIONS REGARDING SCOPE SHALL BE BROUGHT TO STARBUCKS /� S �� -y. PROJECT # 153 ' I ATTENTION FOR CLARIFICATION- RESPONSIBILITY INDICATED BELOW ISSUE DATE: 100%09,08,2017 0 0 M X0101 M X0101 0 0 I��\ 0 I - -. t...._ �� U M X0101 •♦ r.14 ® 10"m 10"m • MEANS FURNISHED, PERMITTED ANDINSTALLED BY THE PARTY INDICATED. EED�APDESIGN NAGER. RYAN WONG SUZANNE SULLIVAN ax -__ RESPONSIBILITY PRODUCTIONDESIGNER: HEB RNI 10"m co -- 280 280 =,, - a ` -- WORK DESCRIPTION CHECKED BY: TOM CONNER 12 a r� - 10 m 1 �� LANDLORD STARBUCKS v 280 !_ 'Ill \\� HVAC UNITS, CURB AND STRUCTURAL X I N) HVAC UNIT ECONOMIZERS AND RELIEF X Revision Schedule w _ _ _ CI SMOKE DETECTORS IN DUCTWORK AND INTERLOCK X Rev Date By Description D - , - , , , , , , ;, , , , , ,, , , , , - - - - - - - - u , - . _ - : : : , . - - - - - - - - - - - - - - - - - - ate , . ,t- , THERMOSTATS AND CONTROLS X U . M 10721 10 01280 L-. ,, , EMS CONTROLS MOTORIZED DAMPERS FOR BACKDRAFT X X 6. d.� .-.._.. DAMPEREXHAUSFAN, CURB AND MOTORIZED X M Q DUCTWORK 12"OR LARGER X SHEET TITLE: N DUCTWORK 10"OR SMALLER X v MOTORIZED DAMPERS FOR CONNECTIONS X MECHANICAL HVAC GAS SERVICE AND METER X P LAN 21 4 8' GAS PIPING TO SPACE X G SCALE:AS SHOWN E) CO Scale 114-.1,0- GAS PIPING TO HOT WATER TANK X N GAS PIPING TO HVAC UNITS X SHEET NUMBER: 1ST FLOOR - MECHANICAL HVAC PLAN LOUVERS FOR INTAKES, EXHAUST AND X 1 PRESSURE RELIEF M-1101 Sale 1/4"= 1'-0" HVAC Schedulel MECHANICAL EQUIPMENT SCHEDULE-"M" MECHANICAL ROOF PLAN NOTES \ j Design ID Count Description RESPONSIBILITY Comments DESIGN ID COUNT DESCRIPTION RESP. COMMENTS ,� X0101 17 SUPPLY DIFFUSER GC TITUS TDC#3 10"DIA NECK,24"x24"FACE A. ALL IS NEW UNLESS NOTED OTHERWISE. lir 11111146, X0102 14 SUPPLY DIFFUSER GC TITUS FL-20,2.0"SLOT WIDTH, 1-SLOT, 8" RTU-1 1 PACKAGED ROOFTOP UNIT GC-GC TRANE YHC102, 8.5 TON NOM. B. INSULATE DUCTWORK PER CODE AND SPEC. INLET, 2 FT LONG, BORDER TYPE 11, SATIN j CAPACITY, 3400 CFM @ 1.1 ESP MAX., REQUIREMENTS ON M-0001, M-0002 AND M-0003(ALL NOT ANODIZED FINISH 2O8V/3 PHASE, MCA=42.0, MOCP=50, SHOWN). COORDINATE CLEARANCE REQUIREMENTS X0103 2 SUPPLY DIFFUSER GC TITUS TDC#3 6"DIA NECK, 12"x12"FACE EER=12.4, IEER=14.7, 12OMBH INPUT, AFUE=80%, UNIT WEIGHT(INCL. FOR ADDED INSULATION. X0104 4 RETURN GRILLE GC TITUS 350 RL 22"22"NECK, 24"x24"FACE CURB)=1150 LBS.,WEIGHT X0105 2 RETURN DIFFUSER GC TITUS TDC#3 6"DIA NECK, 12"x12" FACE ECONOMIZER AND BAROMETRIC C. SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ALL RELIEF. EXPOSED DUCTWORK, DIFFUSERS, GRILLES, ETC.. RTU-2 1 PACKAGED ROOFTOP UNIT GC-GC TRANE YHC102, 8.5 TON NOM. D. COORDINATE WITH ELECTRICAL CONTRACTOR FOR ©2017 STARBUCKS COFFEE COMPANY CAPACITY, 3400 CFM @ 1.1 ESP MAX., POWER CONNECTIONS TO ALL MECHANICAL 208V/3 PHASE, MCA=42.0, MOCP=50, EQUIPMENT. EER=12.4, IEER=14.7, 120MBH INPUT, STARBUCKS COFFEE AFUE=80%, UNIT WEIGHT(INCL. E. REFERENCE LANDLORD WORK LETTER FOR DIVISION OF CURB)=1150 LBS., R410a, ELECTRICAL SCOPE OF WORK AND COORDINATE WITH COMPANY ECONOMIZER AND BAROMETRIC STARBUCKS CONSTRUCTION MANAGER. 2401 UTAH AVENUE SOUTH RELIEF. SEATTLE, WASHINGTON 98134 X0106 2 THERMOSTAT AND SENSOR(1 EACH PER GC-GC THERMOSTAT,N, HONEYWELLL W SHEET NOTES (206) 318-1575 UNIT SERVED) TH8320U: SENSOR, HONEYWELL C7189U1005 X0107 1 CO ALARM GC-GC CARBON MONOXIDE-MODEL GE NX-8 1. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER THESE DRAWINGS AND SPECIFICATIONS ARE X0108 1 CO2 ALARM GC-GC ESENSE FAILEED CO2 ALARM CONNECTION TO ALL MECHANICAL EQUIPMENT. CONFIDENTIAL AND SHALL REMAIN THE SOLE W/PLUG-IN POWER SUPPLY,WALL PROPERTY OF STARBUCKS CORPORATION, MOUNTED W/LCD DISPLAY, DIGITAL 2. ROOFTOP AC UNIT PROVIDED AND INSTALLED BY GENERAL WHICH IS THE OWNERK. THEYOF H THENOT COPYRIGHTEIN DISPLAY ALARM INDICATION& CONTRACTOR,VERIFY EXACT LOCATION PRIOR TO START OF THIS WORK. SHALL NOT BE AUDIBLE WARNING ON HIGH ALARM ANY WORK.VERIFY THAT OUTSIDE AIR INTAKE IS LOCATED A REPRODUCED(IN WHOLE OR IN PART), SHARED POINT. MINIMUM OF 10'-0"FROM ANY VENT OR EXHAUST OPENINGS. WITH THIRD PARTIES OR USED IN ANY MANNER ROOF PENETRATIONS SHALL BE PROVIDED BY GENERAL ON OTHER PROJECTS ORE TENSIONS TO THIS X0109 1 CO2 SENSOR GC-GC HONEYWELL C7232A WALL MOUNTED CONTRACTOR, CONTRACTOR SHALL CUT, PATCH, FLASH,AND PROJECT WITHOUT THE PRIOR WRITTEN SENSOR WITH LCD DISPLAY CONSENT OF STARBUCKS CORPORATION. X0110 1 CO SENSOR GC-GC CARBON MONOXIDE SENSOR- COUNTERFLASH AS REQUIRED. THESE DRAWINGS AND SPECIFICATIONS ARE MODEL GE260 INTENDED TO GN INTENT FOR A 3. REFER TO DETAILS ON SHEET M-5001 FOR FURTHER PROTOTYPICAL TARBUCKSRESS ISTORE(WHICH IS X0111 2 REMOTE TEMPERATURE SENSOR GC-GC HONEYWELL C7189U1005 INFORMATION. FAN SUBJECT TO CHANGE AT ANYTIME)AND DO 10632 1 FAN-RESTROOM EXHAUST GC-GC REFLECT ACTUAL SITE CONDITIONS. FAN-GREENHECK G-070-VG,260 4. ICE MACHINE: CONTRACTOR SHALL PROVIDE AND INSTALL NEITHER PARTY SHALL HAVE ANY OBLIGATION CFM, 115V/1 PHASE. PRECHARGED REFRIGERANT LINES FROM ICE MACHINE TO NOR LIABILITY TO THE OTHER(EXCEPT STATED 10721 1 FAN-DT AIR CURTAIN-221N 560MM GC-GC INCLUDE AS PART OF DT WINDOW REMOTE CONDENSER, SIZED PER MANUFACTURER'S ABOVE)UNTIL A WRITTEN AGREEMENT IS PACKAGE REQUIREMENTS. COORDINATE WITH G.C. FOR EXACT FULLY EXECUTED BY BOTH PARTIES. 10873 1 FAN-RESTROOM EXHAUST ROOF CURB AND GC-GC CURB-GREEN HECK GPI-17-G12, LOCATION AND SUPPORT OF CONDENSER. REFER TO DETAILS DAMPER DAMPER-GREENHECK WD-90-PB-8X8 ON SHEET M-5001 FURTHER INFORMATION. ROOF PENETRATIONS (WITH BACKDRAFT PREVENTER) SHALL BE PROVIDED BY GENERAL CONTRACTOR, CONTRACTOR STARBUCKS TEMPLATE VERSION i2017.05.18 SHALL CUT, PATCH, FLASH,AND COUNTERFLASH AS REQUIRED. ��en PROFFss 5. ROUTE 1"GAS LINE ON ROOF AND CONNECT TO ROOFTOP UNIT, No,• GI N E F '0 CONTRACTOR SHALL PROVIDE GAS SHUT-OFF VALVE AND 6" t� 4� lr 1 I DIRT LEG PRIOR TO FINAL CONNECTION. _J 8960 E 0 / 6. ROUTE GAS LINE ON ROOF. SEE DETAIL 8 ON SHEET M-5001 FOR , 0" ° a MORE INFORMATION. OREGON /„ yIn 7. 10'-0"CLEARANCE FOR OUTSIDE AIR INTAKE. �p_ sFp 9 Jr,01 O CDN M 8. 3"WATER HEATER FLUE, EXTEND ABOVE ROOF AND PROVIDE 0 0 RAINNENT CAP PER MANUFACTURER'S RECOMMENDATIONS. EXPIRES:II c'I I . ROOF PENETRATIONS SHALL BE PROVIDED BY GENERAL — _ ❑ ❑ ❑ ❑❑ COUNTERFLASH AS R QCTOR, C IRED.�TOR LL CUT, PATCH, FLASH,AND i //� / \ ®®® / 9. EXISTING 3"VENT THROUGH ROOF TO REMAIN, FIELD VERIFY / \ 0 _ " — _ ` EXACT LOCATION PRIOR TO START OF ANY WORK. REFER TO GPD Engineering and Architecture / \ 10 M 10632 \* / \ PLUMBING PLANS FOR CONTINUATION. Professional Corporation / \ M 10873O ..-• / N N 10. ROOFTOP EXHAUST FAN PROVIDED AND INSTALLED BY GENERAL 520 SOUTH MAIN ST. SUITE 2531 / \ / \ CONTRACTOR,VERIFY EXACT LOCATION PRIOR TO START OF ANY AKRON,OH 44311 M RTU-2 WORK.VERIFY THAT DISCHARGE IS LOCATED A MINIMUM OF 10'-0" P: 330.572.2100 F: 330.572.2101 / \ FROM ANY OUTDOOR INTAKES. ROOF PENETRATIONS SHALL BE / / O40 \ / \ PROVIDED BY GENERAL CONTRACTOR, CONTRACTOR SHALL CUT, GPD PROJECT NO: 2016355.37 / 1 / \ PATCH, FLASH,AND COUNTERFLASH AS REQUIRED. Z, 1 / ©RTU-1 \ 11. 3/4"GAS DOWN THRU ROOF TO WATER HEATER. 1 / GOO v ai N: - / I I , 1 ❑ . zl I I r I w \ / E' ;! ; i _ Q \ 0/ I 1 I- 1 i I 00 / \ / f` M \ \ / / ©0 >- ON _ \ > LL N m \ / w cv m W o a 0 cc i 1-1/2" 0 , 1„ Q o H H La `� w U w pQ n 1-1/2" aO Q 3O N. 0 E 0 a � a r H o — STORE #: 3389 0 O PROJECT #: 15375-032 O �" TI, 'L _L' II 0 IT Ti II 11 II II ❑ ISSUE DATE: 100%09.082017 o 0 DESIGN MANAGER: RYAN WONG U, LEEDOAP: SUZANNE SULLIVAN PRODUCTION DESIGNER: HEB N CHECKED BY: TOM CONNER I 1; o a m Revision Schedule a) Rev Date By Description co m IW ❑ DU Li - u SHEET TITLE: NMECHANICAL ROOF ✓ PLAN SCALE:AS SHOWN i--- 3 N 1 © e.142-10 4' 8' SHEET NUMBER: N 1ST FLOOR - MECHANICAL ROOF PLAN M-1102 scale 1/4"= 11-0" 4tte le ..;... * NOTES: 1. PROVIDE SUPPORT FOR DIFFUSER&CAP PER CODE. COORDINATE CONNECTION/METHOD OF 2. DETAIL CAN BE USED FOR SUPPLY OR RETURN. CONNECTION TO STRUCTURE IN FIELD 3. F&I EARTHQUAKE SUPPORT PER A.H.J. AND WITH STRUCT. PLANS(TYP.) SUPPLY OR RETURN RIGID DUCT. ® RIGID HANGER STRAP ELBOW ©2017 STARBUCKS COFFEE COMPANY Y FLEX DUCT.SELF TAPPING \1/4glir UNISTRUT HANGER LIN RTAUTPULLINSIDE STARBUCKS COFFEE SCREWS t THREADED a LOW 411RODT el= CLG DIFFUSER. FASTEN TO CAP COMPANY W/SHT MTL SCREWS, MIN ONE 2401 UTAH AVENUE SOUTH PRESSUR 1111I DUCT PER SIDE. SEAL JOINT AIR TIGHT. SEATTLE, WASHINGTON 98134 at INSTALL CABLE SEISMIC RESTRAINTS =� FLEX DUCT CLAMP. (206) 318-1575 FOR DUCTS OVER 48" BOTH LONGITUDINALLY AND WIDE, TURN UNDER BOT ROUND INSUL STUB DUCT THESE DRAWINGS AND SPECIFICATIONS ARE OF DUCT&FASTEN TRANSVERSELY PER SMACNA TYP SUSP LAY-IN SAME SIZE AS FLEX DUCT. CONFIDENTIAL AND SHALL REMAIN THE SOLE _... REQUIREMENTS_ CEILING PROPERTY OF STARBUCKS CORPORATION, _DUCT SIZE I HANGER SIZE, MAX. SPACING IIMI SQUARE TO ROUND NO LABOR WHICH IS THE OWNER OF THE COPYRIGHT IN UP THRU 2 SQ.FT. 1"x 1/16" 8,-0" AaCOLLAR. THIS WORK. THEY SHALL NOT BE 2 THRU 4 SQ.FT. I 1"x 1/8" 8'-0" REPRODUCED (IN WHOLE OR IN PART), SHARED _4 THRU 10 SQ.FT. 1"x 1/8" 6'-0" CLG DIFFUSER. FASTEN TO CAP W/SHT MTL WITH THIRD PARTIES OR USED IN ANY MANNER OVER 10 SQ.FT. I-1"x 1/8" 4'-0" SCREWS, MIN ONE PER SID. SEAL JOINT AIR TIGHT. ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT WITHOUT THE PRIOR WRITTEN DUCT HANGING DETAIL 1 LAY-IN CLG DIFFUSER DETAIL THESE DRAWINGS AND SPECIFICATIONS ARE C sone 12"= -0" \ sad, CONSENT OF STARBUCKS CORPORATION. J sa 12"= -0" INTENDED TO EXPRESS DESIGN INTENT FOR A 1' PROTOTYPICAL STARBUCKS STORE(WHICH IS SUBJECT TO CHANGE AT ANYTIME)AND DO NOT REFLECT ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO THE OTHER(EXCEPT STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY EXECUTED BY BOTH PARTIES. STARBUCKS TEMPLATE VERSION 12017.05.18 �t� En V'V<UFFSS �GINEFR o2 rt . 8P ► 20 GA. GALVANIZED SHEET 69A ,� METAL HOOD r /- '' it' v�// 0 ' ROOF MOUNTED EXHAUST FAN FILL OPENING WITH FOAM UNIT AS SCHEDULED OREGON SHOP FABRICATED SHT ROUND INSUL STUB DUCT \ NEA LL SIZE CONDENSATE DRAIN (MIN 3/4") / GREENHECK,WITH ROOF CURB, MTL CLG DIFFUSER CAP SAME SIZE AS FLEX DUCT �� INSULATION AIR TIGHT REST ROOF DRAIN AIR&WATERTIGHT BACKDRAFT DAMPER, FAN SPEED It `SP.g 201?�� NET INSIDE DIM. SAME AS AFTER LINES ARE PENETRATION,TYP. CONTROLLER, FACORY MOUNTED 9'% r� DIFFUSER NECK111. I INSTALLED FLASHING & DISCONNECT SWITCH AND WIRE MESH �V M.MP �( EQUALIZING GRID FLEX DUCT CLAMP I ROOF CURB COUNTER FLASHING SCREEN. EMPIRES: /N)I 1(U PERPEND TO STUB DUCT. FLASHING, ROOFING,AND ROOF UP OVER CURB � SECURE FAN TO CURB WITH SHT FLEX DUCT. PULL INSIDE SEALING PER ROOFING MTL FASTENERS @ 12"O.C. FULL SIZE OF DIFFUSER GALVANIZED IllI PER ROOFING LINER TAUT _ CONTRACTOR'S (MINIMUM 2 PER SIDE) CAP. HEIGHT FROM MESH SCREENING z CONTRACTORS DIFFUSER NECK TO STUB II�IIII REQUIREMENTS. REQUIREMENTS. CNTRLN. FABRICATE FROM N -' .' FACTORY CURB 22GA PERF SHT MTL(3/16" r �1�� TOP OF ROOF DECK ROOF UP OVER CURB PER GPD En ineerin and Architettlikure HOLES ON 1/4"CNTRS). �, g g ROOFING CONTRACTOR'S FACTORY CURB �� Professional Corporation y�. REQUIREMENTS. p T. SUITE 2531 r is O 520 SOUTH 00 :AKRON, OH 44311 f � // �� ,,_______i all �: P: 330.572.2100 F: 330.572.2101 UNISTRUT ANCHORED TO CURB. REFRIGERANT LINESNG SUPPORT . uv�. •4 - NOTES:PROVIDE SUPPORT CLG DIFFUSER. FASTEN TO CLAMP REFRIGERANT LINES TO (INSTALL PER CODE) FOR PFRAMENETRATIONS ONS ° ° / ° ` ° GPD PROJECT NO: 2016355.37 FOR DIFFUSER&CAP CAP W/SHT MTL SCREWS, MIN UNISTRUT. Pr o ' v ° PER CODE ONE PER SIDE. SEAL JOINT AIR I� BACKDRAFT DAMPER SUPPLIED 2. EQUALIZING GRID TIGHT NOTE: THIS ROOFING PENETRATION DETAIL IS TO BE USED FOR REFER TO MECH REQ'D ON SUPPLY AIR REFRIGERANT FLEXIBLE CONNECTION PLAN FOR DUCT I EXHAUST DUCT&ENCLOSURE AS DIFFUSERS ONLY LINES SERVING CONDENSER AND/OR HEAT PUMPS. TYPICAL SIZES, TYP. REQ'D BY CODE. ai U WI LAY-INCLGDIFFUSER DETAIL (LIMITED CEILING SPACE) (5) ROOF PENETRATION DETAIL (6m ROOFTOP AIR HANDLING UNIT DETAIL O ROOF EXHAUST FAN = Q �`*� I— I N YN- ce O 06 2 >- 0 c' I U N w — ti 0 = co Q d CONDUCTORS AS NEEDED LLI ca W )Z n N 120V 2 U U > o in HVAC DUCTWORK PROVIDE Z LL < >(I) 0 c GALVANIZED PIPE 4x6 x 12"TREATED CONTROL WIRINGf , U r Et uo CLAMP DO NOT CLAMP SUPPORT BLOCK W/V- SAMPLING TUBE U U�• FOR FAN SHUT W W p Q ' -e TIGHT NOTCH SIZED FOR DUCT DOWN O QO r• 0ar 1/4"x 1-1/2"GALV ROOF WALK MAT BASE 1/2"C,4#14 c E LAG BOLT SHEET IM.�, 18"x 18"x 1/2"THICK 0 D a. p im al_/r Int STORE 3389 O OVER ROOF DECK 'Ire -- 1/2"C,4#14 PROJECT #: 15375-032 REMOTE ANNUNCIATOR/RESET SYSTEM SENSOR, MOUNT EQUIPMENT TO 100% 0 LOCATED BELOW CEILING NEAR MANAGERS DESK(NOT • ICE MACHINE REMOTE ISSUE DATE: 09.08.2017 SLEEPER PER CODE AND 0- SHOWN). PROVIDE PHENOLIC NAMEPLATE INDICATED ' CONDENSER DESIGN MANAGER: RYAN WONG 0. "HVAC DUCT OR SMOKE DETECTOR". MANUF. REQ. (TYP.4 LEEDDAP: SUZANNE SULLIVAN LOCATIONS). CONFIRM SPACING PRODUCTION DESIGNER: HEB 2 WITH EQUIPMENT VENDOR CHECKED BY: TOM CONNER V • +s' A NOTES: 4X6 SLEEPER MOUNTED S. PRIOR TO ROUGH-IN. 0 0 1) MECHANICAL TO PROVIDE THE COMPLETE DUCT DETECTOR, REMOTE STATION AND ALL ACCESSORIES TO ROOF AND ORIENTED MOUNT EQUIPMENT TO 3 AS NEEDED FOR A COMPLETE&OPERATIONAL SYSTEM. PARALLEL TO DIRECTION SLEEPER PER CODE AND Revision Schedule SUPPORT SPACING FOR PIPE SIZE: Cl) 2)WHEN STARBUCKS SPACE IS MONITORED BY CENTRAL BUILDING FIRE ALARM SYSTEM, GC TO OF ROOF DRAINAGE MANUF. REQ. (TYP.4 3/4"=6', 1"=7', 1-1/4"=8', 1-1/2"= 9' COORDINATE WITH LANDLORD'S ALARM CONTRACTOR TO CONNECT BUILDING ALARM SYSTEM TO DUCT LOCATIONS). CONFIRM SPACING Rev Date By Description co PLACE BASE SHEET OVER ROOFING GRAVEL(IF ANY).SET BLOCKS DETECTOR AUXILIARY CONTACTS. I WITH EQUIPMENT VENDOR FREE ON BASE SHTS. STACK BLOCKS&NAIL TOGETHER WHERE 3) MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL DUCT DETECTOR WITH MINIMUM OF TWO SETS OF PRIOR TO ROUGH-IN. U REQ'D TO ELEVATE PIPING. INSTALL GAS PIPE TO ALLOW FOR AUXILIARY CONTACTS. TOP OF ROOF DECK EXPANSION&CONTRACTION. PRIMER AND PAINT EXT. PIPE LIGHT 4) ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL CONTROL WIRING FROM DUCT DETECTOR TO AC �",le -- - GREEN COLOR. UNIT. - M Q PIPE SUPPORT DETAIL C DUCT DETECTOR DETAIL EQUIPMENT SUPPORT DETAIL SHEET TITLE: CO 91N Scale 12"= 1'-0" Scale 12"= 1'-0" �,e 12"= 1•-o„ MECHANICAL DETAILS N- ,- SCALE:AS SHOWN r N SHEET NUMBER: M-5001