Plans (3)
M EC2017 - 00429 rsw... ., ; ` ` GENERAL NOTES E I. REPLACE ALL FLOOR GRILLS IN DORM ROOMS WITH KEES SEG-g5P3 SECURITY GRILLS Equipment Schedule Air Handlers Tag# Model CFM Voltage Coil btuh Control GF-3 ML193UH04536B 1000 120/1 X5645 45k Vpro 8000 Air Conditoners Tag# Tons Model Electrical MCA MOCP Serves AC-3 2.5 13ACX-030 208/1 18.7 30 GF-3 Exhaust Fans RECEIVED Tag# Brand/Model CFM EF-1 Broan L100 100 JUN 8 2017 CITY OF TIGARD CRAWL SPACE CLOSET BUILDING DIVISION 5200 5201' —V DNI---.1: I_ < < < < < OFFICE OFFICE OFFICE FFIGE OFFICE Gas Piping Diagram 5201 5202 5203 5204 5205 NO WORK 1 / f �D \ O 'GF 3 Y HALLWAY D l l `� a 30'• - I 5201 - ao I OPEN TO :el A20 i90CBELOW ----- - __ = aNWN 2Ib Generator Meter OPEN TO c i BELOW u_ Gas Calc Sizing -Standard Pressure Code Required Outdoor Ventilation Air / OMSC 2010 / \ co Section Max Length Section Load Size Zone Information From table From table calculated results to 403.3 g 403.3.1.2 see"formulas"note below ri A to B 200' 355k 1.25" B to C 200' 310k 1.25" Room net Occupants , occupants Exhaust a, Lil B to D 200' 45k 0.75" occupiable Occupancy OSA CFM OSA CFM per Exhaust Effectiveness x 1/2 OSA CFM CFM co Unit-Zone Room sq-ft classification per person per sq-ft 1000 sq-ft CFM `g factor see 403.3 for Room for room to to GF-3 003 .780 Office 5.0 0.06 5 0.8 2.0 71 0 - - S: 005 920 Activity 20.0 0.06 5 0.8 2.3 127 0 m d 004 390 Fitness 20.0 0.06 10 0.8 2.0 78 0 - ` cm 275 w M a b c d e f g h i formulas(reference column letter directly above): g=((d+1000)xa)x1/2 h=((bxg)+(cxa))+f i=exa or i=(manual entry) - - 0 (a)Transfer air is allowed per OMSC 403.2.2 for kitchens,baths,toilet rooms,elevators and smoking lounges. SOUTH BUILDING a a O 1-IVAC 2nd FLOOR PLAN co Y O' Scale I/8" = NO" 16' ii.a.., C7 = W W CD O e 4. W Cad c Its c4 O 4= N Q N GenercAvor Ac-1 Co - I.C &a- g 1 N06" ,t 11 0 a \ i ® cm Is) CS1 ^C ROOM ROOM ROOM . RDOM rW, 5111 5112 5113 5114 V FITNESS 4 ROOM 5004 /zoo. 51 t0la n- NEW DRYER VENT r r /� L —a r / ast _ \ NEN DRYER VENT GORR U to DOWN TO BASEMENT 5115 ® .— - n, - \ la RI I 8f. N. \ RR JAN / 5102 _ 5104 MECH. • ® ��" 0 NEW 70 CFM GEF 'IO 5001 �— © = o , , /ACTIVITY A iii ZN D W ACTIVITY 11 — CORR 1----1 v /1\l' el I� 5U05 CLIMATE \ tool; NG J �� 1 LAU�DRY 5116 5105 ld NTROL 3/y" N� [4N RR 5103 I — 0 002 2VI5101 ELIMINATE \ • / . STAFF 1 UPEl 8 � T 5003 I°i ENTRY GORR m CITY OF TIGARD t Sill REVIEWED FOR C DE COMPLIANCE C V 1Z'¢ , : m - ROOM Approved:1 1 7 Qti-ROOM ROOM Address: /%fl f, a 3'1 510b SIO 5108 v tem Suite#: cE,�i; _ : b so c7 cO 0 c std. (�reasvre By: �.�ti0<h� Date. L � f T MthrLb� Nww) 2 �...-, s i= a OFFICE COPY drawn by: BG • checked by: plot date:6/6/2017 • SOUTH BUILDING SOUTH BUILDING J— M-1 HVAC EASEMENT FLOOR PLAN I-1VAC 1st FLOOR PLAN v O' Scale I/8" = NO" 16' V O' Sale 1/8" = NO" 16' CV 1 Of 2 \ Madrona Recovery Center _