Loading...
Plans (13) BU P2018 - 00032 Cli4'Y 'r COPY GENERAL NOTES CONTRACTOR CONSTRUCTION NOTES RECEIVED4 (REFERS TO ALL AREAS WITHIN 4 WHEEL PARTS DEMISED PREMISES) F `- 2 7 2018 • CONTRACTOR TO REMOVE ALL REMAINING EXISTING STORE FIXTURES AND FLOOR CITY OF fIGARD COUNTERS. BUILDING DIVISION OXFORD • CONTRACTOR TO REMOVE ANY SUSPENDED SIGNS OR OTHER ACCESSORY ITEMS ARCHITECTURE FROM THE CEILING AND/OR WALLS THROUGHOUT THE 4 WHEEL PARTS TENANT SPACE. PREP FOR PAINT. • CONTRACTOR TO DISCONNECT AND REMOVE EXISTING ABANDONED LIGHTING, 1205 Paris Avenue Architecture ELECTRICAL WIRING, CONDUITS AND FASTENERS. Suite 205 Planning 10?? OR ALT WITH EXHAUST FAN Nashville, TN 37212 Interior Architecture 41 • CONTRACTOR TO PROVIDE TOTAL CLEAN OF STORE PRIOR TO NEW 39'-4' CONSTRUCTION. )//:)S% t U J \ • CONTRACTOR TO REMOVE ALL EXISTING ARCHITECTURAL ITEMS (SECURITY DOMES, WALLS, WALL HANGINGS, SOFFITS, FIXTURES, ROOMS, UTILITIES, 7 OrO FURNISHINGS, ETC.), &FINISHES THAT INTERFERE W/4 WHEEL PARTS FINISHES&AS 41 �- PER TENANT FLOOR PLAN. CAP ALL PLUMBING, ELECTRICAL LINES & ANY OTHER Io "C © \ UTILITIES NEEDED IN ACCORDANCE W/CODES. /;_ ' / © - • CONTRACTOR TO REMOVE ALL EXISTING CEILING TILE AND GRID IN EXISTING 4 J CEILING AREAS EXCEPT EXISTING RESTROOMS TO REMAIN. - L • CONTRACTOR TO REMOVE ALL EXISTING FLOOR COVERINGS (VCT, CARPET, TILE, '!- Ii t0-- --- �_ ---- �-1 o MASTIC, ETC.) THROUGHOUT ENTIRE DEMISED PREMISES UNLESS NOTED 4 V I I O OTHERWISE ON A0.1 FINISH SCHEDULE. CONTRACTOR TO PREP FLOOR TO RECEIVE 00000. ___ , O © NEW WORK. LL 9 • REMOVE ALL EXISTING LIGHT FIXTURES-TO BE REPLACED WITH LED. P © ,/ • HVAC DUCTWORK NOT TO BE REUSED IN ALL AREAS. 'q I# I I/ • REMOVE ALL BLINDS IN EXISTING WINDOWS IF EXISTING. II1, , �� I II ���� II • REMOVE ALL EXISTING CASEWORK THROUGHOUT DEMISED PREMISES. 4 ___2„-/, IL nj ' Iir_-,r -I r_ AA i 1-- \ • CONTRACTOR TO RAISE SPRINKLER HEADS IN AREAS WHERE CEILING TILE AND 41 V O 1 © GRID OO WDECK REMOVEDNDAND CEILINGUP IS TO REMAIN EXPCTOSTO TO UNDERSIDE OER ROOF DECK AND TURN HEADS UP TO DECK. CONTRACTOR TO SUBMIT SPRINKLER SHOP DRAWINGS TO LOCAL FIRE MARSHAL FOR APPROVAL PRIOR TO I Q ® b INSTALLATION/MODIFICATION OF EXISTING SPRINKLER SYSTEM. • CONTRACTOR TO INSPECT ALL EXTERIOR MAN DOORS. REPLACE WHERE FAILING, 4 p I �� Ai u_ _. RUSTED, ECT. COORDINATE NUMBER OF NEW DOORS WIN 4WP PROJECT 'I— �� .. MANAGER 41 Li 4 ,A0 KEYNOTES CONTRACTOR CONSTRUCTION NOTES 4- ,1 0I ® (REFER ONLY TO NOTES NAT ARE INDICATED BY NUMERICAL KEY ON PLAN): V 1 1 0 1. CONTRACTOR TO REMOVE EXISTING DOOR AND FRAME WHERE INDICATED. 0o PREP AREA TO RECEIVE NEW WORK. VERIFY IF ANY DOORS ARE SUITABLE FOR P N SALVAGE AND STORE ON SITE FOR RE-USE. /0 N , 0 2. CONTRACTOR TO REMOVE EXISTING PARTITIONS WHERE INDICATED. PREP AREA ��� - V /A TO RECEIVE NEW WORK. O I O 14, 3. CONTRACTOR TO REMOVE EXISTING PLUMBING FIXTURES, WHERE INDICATED. ''_ © ' I . 1 PREP AREA TO RECEIVE OFF, PLUG AND / OR REMOVE WORK. PLUMBING SUBCONTRATOR SHALL CAP EXISTING SUPPLY, WASTE A DC VENT PIPING AS TIGARD I , i 11 REQUIRED FOR DEMOLITION AND NEW CONSTRUCTION. /' f� I 4. DEMO CEILING. PREP TO RECEIVE NEW WORK. ,i_ o -k 1 10?? OREGON I 5. CONTRACTOR TO DEMO ALL NON-STRUCTURAL WOOD OR METAL FRAMING, 4 I� ABANDONED DUCT WORK, AND ANY OTHER ABANDONED ELEMENTS 11 SUSPENDED FROM CEILING. REMOVE ALL CARPET AND VCT THROUGHOUT. 9 ) J I 4 IT �1' 1Fp TIE IN AT EXISTING 4" SS LOCATION NEAR PROPOSED 6, CONTRACTOR TO TRENCH TO AREAS OF NEW PLUMBING. VERIFY CLOSEST OFFICE COPY RESTROOMS IN LIEU OF TRENCHING FROM EXISTING I POINT OF TIE IN IN FIELD TO MINIMIZE TRENCHING. CITY OP TIGARD I I ® REVIEWED FOR CODE COMPLIANCE �in IF POSSIB E 0 1 0 7. CONTRACTOR TO TRENCH FOR NEW ELECTRICAL CONDUIT LOCATIONS. VERIFY \r . L1, Approved.:-..--W I �,�o ta.11k 1 I ao LOCATIONS IN FIELD WIN TENANT FIXTURE PLAN PRIOR TO TRENCHING TO I I J © �I = I CONFIRM EXACT LOCATIONS. COORDINATE WIN TENANT PROJECT MANAGER. OTC: 21 I� i '. Permit #: f3i,f�-an1{�- oo0-3Z /� 0 8. EXISTING RESTROOMS, FIXTURES, FRP, AND GRAB BARS TO REMAIN UNLESS Address: ) 1 4,c' Pct...c; c H w,Al \ © NOTEDD OTHERWISE. Suite #: i00 /'_ — _ I O 9. REMOVE EXISTING WATER HEATER. SEE PLUMBING FOR NEW WORK. By: -)-f Date: _ , )g '�_ p1 10. SAW CUT AND REMOVE EXISTING MASONRY TO CREATE NEW OPENING FOR 42°X ✓ -I 42' AIR INTAKE LOUVER WHERE INDICATED. CREATE OPENING AS HIGH AS A_ O I J a POSSIBLE TO ALLOW FOR NEW STRUCTURE AT EVEN BLOCK COURSING. VERIFY All measurements and items portrayed HEIGHT IN FIELD. SEE STRUCTURAL. PREP AREA TO RECEIVE NEW WORK. on this sheet are deemed to be 41 accurate by architect, however all 11. CONTRACTOR TO REMOVE EXISTING CONCRETE AND SUBSTRATE AS NECESSARY bidding Contractors should field verify �� �jI FOR NEW WORK. SEE A1.0 FOR EXTENTS OF NEW WORK. the actual conditions. Any changes to dl 111 0 12. CONTRACTOR TO SAW CUT AND REMOVE EXISTING MASONRY TO CREATE NEW the scope of work, and thus potential G 14'-0°W X 12'-0"H MASONRY OPENING. PREP AREA TO RECEIVE NEW WORK. change orders, should be identified and El © 0 © communicated in your bid submittal to O ,1 13. CONTRACTOR TO SAW CUT AND REMOVE EXISTING MASONRY TO CREATE NEW the General Contractor. Y 8'-0'X 8'-0'MASONRY OPENING. PREP AREA TO RECEIVE NEW WORK. C Q s /),r �''01OIUITIZTIU2Z72Z727101dI0�lT 1U 1ZlZTlZ 17T_1ZTI� m 14. CONTRACTOR TO SAW CUT AND REMOVE EXISTING MASONRY TO CREATE NEW This drawing and the design shown is �VvOPENING FOR MAN DOOR WHERE INDICATED. PREP AREA TO RECEIVE NEW the property of the architect. The 0 II WORK. p r2 reproduction, copying or use of this 15. REMOVE EXISTING BREAK METAL AT COLUMNS AT FRONT WINDOWS WHERE drawing without their written consent is INDICATED. PREP AREA TORECEIVE NEW WORK. prohibited and any infringement will be subject to legal action. ® ® 16. REMOVE EXISTING SUSPENDED SOFFIT WHERE INDICATED. PREP AREA TO RECEIVE NEW WORK. _ ,,,m, - ` -- 17. CONTRACTOR TO REMOVE EXISTING RED TILE BASE IN EXISTING RESTROOMS. PREP AREA TO RECEIVE NEW WORK. Job Number: 1803 L J L J L J Date: 01.31.2018 Revisions: Revisions: II DEMOLITION PLAN Revisions: DEMOLITION PLAN SCALE: 1/8"=1'-0" Sheet Number D1 ■ 0