Plans (19) MFC201 ' 7 - 0008 1 KEYNOTES GENERAL NOTES 1;.I 1 3 15.100 ROUTE PIPING THROUGH JOIST SPACE. 1. THE NATURAL GAS DEMAND SHOWN IN CUBIC 4 COORDINATE WITH HVAC AND OTHER FEET PER HOUR (CFH) IS BASED ON A HEATING SPECIAL INSPECTION REQUIRED TRADES PRIOR TO INSTALLATION. DO VALUE OF 1000 BTU PER CUBIC FOOT AND State of Ore On Structural S la Code NOT INSTALL PIPING DIRECTLY UNDER SPECIFIC GRAVITY OF 0.6. CONTACT LOCAL 9 SKYLIGHT WELLS UNLESS INDICATED UTILITY FOR EXACT LOCATION AND SIZE OF GAS OTHERWISE ON PLANS. COORDINATE METER, GAS PRESSURE, SIZE AND TYPE OF NI Concrete and Reinforcing Steel WITH SPRINKLER CONTRACTOR PRIOR PIPING AND VALVES REQUIRED FOR CONNECTION Ou. ar ►� Bo1�InstalledinConcrete TO INSTALLATION IN ORDER TO TO METER. VERIFY CORRECT GAS PRESSURE MAINTAIN REQUIRED CLEARANCES DOWNSTREAM OF SERVICE REGULATOR AFTER GAS r ❑ •4 a1 Moment-Resisting Concrete F : FROM SPRINKLERS. REFER TO PIPE UTILITY COMPLETES INSTALLATION. v 5 SUPPORT DETAIL FOR INSTALLATION. ��\ 0 Re orcingSteel 8,Prestressing S ==lTendona 2. SANITARY SEWER PIPING SHOWN IS BASED ON W � „ • 15.101 COORDINATE CONNECTION OF NEW 1" 1/4" PER FOOT FALL FOR ALL PIPING 2 1/2" .1 Structu 1 Welding WATER METERS TO EXISTING 3" DOMESTIC AND SMALLER AND 1/8" PER FOOT FALL FOR ❑ High-Stren• tBolting WATER SERVICE. PROVIDE PRESSURE ALL PIPING 3" TO 6". COORDINATE BUILDING REGULATOR DOWNSTREAM OF METER AND SEWER LOCATION AND INVERT ELEVATION WITH sac _ ❑ StructuralMasLnry SET TO 55 PSI. REFER TO THE PLUMBING CIVIL DRAWINGS. OCrI�] VTSI i'...4 , 0 Reinforced Gyps 'oncrete FIXTURE SCHEDULES. 3. INSTALL VTR'S A MINIMUM OF 24" FROM i , 0 Insulating Co, - PARAPET WALL AND A MINIMUM OF 10 FT. FROM '2.0\7❑ SpreyAppli=• Fre R"- ' Materiels OUTSIDE AIR INTAKE OF ROOFTOP EQUIPMENT. FEB SEISMIC NOTES • ❑ Pilings, riRed Piers and ,. 4. INSTALL LRC CONTINUOUS PENETRATIONS.S SEALANT TJOINT AT ALL 1� � Y O�Ci1�j OS1d� tJIL� ❑ S ' « _.e REFER TO SEISMIC RESTRAINT SHEET SR1 FOR 5. FOR PIPING ROUTED ON EXTERIOR WALLS, ROUTE 0 =pecialGradng,Excavation and n•+ e INSTALLATION DETAILS. REFER TO THE SPECIFICATIONS FOR FURTHER INFORMATION. PIPING ON THE INTERIOR SIDE OF INSULATED IA Smoke-ControlSystems WALL TO PROVIDE FREEZE PROTECTION. ❑ Other Inspections 6. INSTALL FLUES A MINIMUM OF 8 FT FROM ROOF , dr EDGE AND/OR PARAPET WALLS AND 10 FT FROM EQUIVALENT NOMINAL PIPE SIZES OUTSIDE AIR INTAKE OF ROOF TOP UNITS. PLAN SIZE POLYPROPYLENE PEX 7. PROVIDE START-UP ASSISTANCE FOR ALL (COPPER) HOT WATER COLD WATER GAS-FIRED UNIT HEATERS. 1/2" 1/2" 1/2" 1/2" GAS LOADS 8. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE 3/4" 3/4" 3/4" 1" AND BECOME FULLY ACQUAINTED WITH THE HENDERSON OUTLOT BUILDING (5 PSI) LOAD (CFH) 1" 1" 1" 1 1/4" EXISTING CONDITIONS OF THE PROJECT. EXISTING ENGINEERSN UH1 250 1 1/4" 1 1/2" 1 1/4" 1 1/2" CONDITIONS WERE TAKEN FROM ORIGINAL UH2 250 1 1/2" 2" 1 1/2" 2" DRAWINGS AND MAY NOT REFLECT EXACT 8345 LENEXA DRIVE,SUITE 300 TENANT (LOW PRESSURE) LOAD (CFH) 2" 2 1/2" 2" N/A AS-BUILT CONDITIONS. COORDINATE NEW WORK LENEXA,K566214 VERIZON WIRELESS RTU1 150 2 1/2" 3" 2 1/2" N/A AND DEMOLITION WITH OTHER DISCIPLINES AND wxo9137425000 iD[ 9131425001 VERIZON WIRELESS RTU2 105 3" 3 1/2" 3" N/A EXISTING CONDITIONS PRIOR TO CONSTRUCTION. www.hei-eng.com t 1592095935 TOTAL 755 4" 6" 4" N/A 9. AT CONTRACTOR'S OPTION, IN LIEU OF COPPER NOTE: ALL TENANT METERS ARE LOW PRESSURE NOTE: REFER TO SPECIFICATIONS FOR WATER PIPING, PEX OR AQUATHERM PIPING MAY APPROVED MANUFACTURERS BE USED. REFER TO EQUIVALENT PIPE SIZE SCHEDULE AND SPECIFICATIONS. 0 0 0 0 0 0 1I 00 CO ( 1 I I I Z 1" WATER METER z 3" DOMESTICGAS ENTRY GAS METER BANK I I I w I l ! • WATER ETR ` REF CIVIL REF 1-MP02.2 as ETR SPRINKLER REF TENANT GAS LOADS O Et ROOM ETR FOR TOTAL LOAD Z ! t l !� 2 1/2" GAS ETR I I ®®I 1 I C0 0 1.— — ___..__ _._....._.__.. .__ GAS PIPE DOWN TO DEMO 6" YCO Z I INDIVIDUAL TENANT 3" VEN ( IE = 91.50' p i ► EXISTING 3/4" I illi � € // 1 1/4 I GAS PIPING 1 - - f>te.�? mm.mm w....s, METERS TYP ETR z Et m / r 3 — — —G— — — si ip SMPLING PRT --I 0 \-3/4" j 1 X3/4" ETR I € KEEP INVERT OF PIPE 1 VTR WITH 6" YCO6" ETR �3 4" l - - - I / n - JLOW AS POSSIBLE F•' CONTINUE E� ETRfr ETR - 1 r GON ROOFekS 1"CW ESS !lir FUTURE TENANT TIE I UNDERGROUND ill SS t • • SS\l LITJ I- 0 x co I I I I REF 2-MP23.21 4" ..... _. _....._ -._ — i— 6" ETR ? rn 1 A { ELECTRICAL n , THROUGH E AN I1 �/ I - I CAP GREASE WASTE THROUGH TENANT - SPACE 4 ETR II 4" ETR 0 o 1 PIPE 5' FROM,,EGW i ' W • n •1• • • e w 7-3/4" 15.101 I / rr s ETR I I i (15.100, 1 I TENANT WALL 4„ , I `, /a ', I I I ! I �� Q o O ci TYP ..� -, • s 1500 GALLON YCO w Z I IE = 94.5' i GREASE ETR 8 --_ F- is r- - I TERCEPTOR Q Q o 1 i E 1 o J r l DEMO I ETR a. J FINISHED FLOOR ELEVATION = 100.00' , i I 1= EXISTING 3/4" 7 I MOUNT ON / sts GAS PIPING I REVISIONS t COLUMN AT 3/4„ I 6O"AFF I h. / \ CAP FLUE AND la REGULATOR I VE ROOF ' GAS ROOF X 1 I ! i I t REF 3-MP02.2N NETR ON _ .. .._ .- -- ��__ _ _. ___ _ _ _ _ _ _ _ _ _ _ _ _ ,:y- _ _ _ CI _ _ _ _ . .._.UH2 _01- _ _ _A 1 _Rett REF ARCH S 0),z , 1" GAS UP _.-- Ili II CVTR ( 1 1 I I 1 \ I T I ETR ; \ EFV RELOCATE UNIT •� SS t1 ill H1 , UH2 12'-0"AFF 1'-8" 1 1/4" HEATER, THERMOSTAT, CITY OFTIGARD °gE2s.16 A 4" ETR 1Jr 4' ' DOWNSTREAM FLUE, AND GAS PIPING t '' ETR F SET THERMOSTAT YCOTR e I I 1 4 I TO 60' OF EFV ! I FOR CODE COMPLIANCE �•i I REF 2-MP02.2 A, ,royd f.t-J BCRA NO. ► F - - - - 'I FLUE THRU O CS 0-1 ! 1 TYP C, I 1500 G LLO �I 3" VENT t l ! I I I I REF OOFMPO2.2 ! 1 r Os 1i ;�` nee °°° FRE O GREA E ETR I A•dim:: atiMiV �,h131TIO �aib INTERCE TORE 1 0-1 ETR, ,r,,,, I S tells 00 SHEET BILE • 1 i I I 1 1 ! IDates i 4" ETR • 4 • ETR II 3 .. .. B ;r. Apia A/��( l , / OVERALL YCO 1 IE = 95.5' tt WCO ETR I 4 I li I 1 • (il G I (/{L MECHANICAL ETR T' STORM O ETR \�ROTORM POF IPINGN D j 'I / OFFICE COPY PLUMBING ETR TYP 1 • erni A= ill _ ....___....... ....... _. ___ ___ ._ iw...,.r. .._ _.. ..._ _ w.w ._.,.�.�,,.. ,,< -�:.::: ...<,..,,a,...,.. A'!�'I ._._..._. ._. ..._.».— __ _ _.._..___.. ! 1 : .a.W.;w >.m:>•Az .._._.._:�»» : aa;.W..:..,,nw. .,..»,...atm«, 1 p .,.1 4. _' _ .._.._...._.,... _... ......_......_.... - _ _.._.__...._ _ j PLANS , ii r" I i 1 1 1 ( I ( 1 1 i 1 i I ! BCM =' )) j{ i — ® ®V —4 —� ® � - .•� '_- -_ I } OCOPYRIGHT 2015 RCM INC.ALL RIGHTS RESERVED iI I �I I I 11 I 1I 1 MP01 . 2 N Q MECHANICAL FLOOR PLAN vs- = 1'—O" rzi Z W N I NATURAL GAS PRESSURE REGULATOR SCHEDULE GAS UNIT HEATER SCHEDULE MECHANICAL SYMBOLS PLUMBING SYMBOLS 1;:I MANUFACTURER MARK AREA SERVED MANUFACTURER/ GAS HEAT OUTLET SENSUS METERING SYSTEMS.. - INVENSYS - EQUIMETER FISHER ITRON MODEL INPUT (MBH) PRESSURE CAPACITY MODEL BODY SIZE *SPRING MINIMUM CAPACITY MODEL BODY SIZE *SPRING MINIMUM CAPACITY MODEL BODY SIZE *SPRING MINIMUM UH1 OUTLOT BUILDING REZNOR / UDAP-250 250 OUH2 THERMOSTAT —SS— SANITARY SEWER 8 4' SETPOINT RANGE NUMBER INLET-OUTLET RANGE ORIFICE RANGE NUMBER INLET-OUTLET RANGE ORIFICE RANGE NUMBER INLET-OUTLET RANGE ORIFICE UH2 MODINE / PDP250 250 IR (wc) (CFH) (INCHES) (IN WC) (IN) (CFH) (INCHES) (IN WC) (IN) _ (CFH) (INCHES) (IN WC) (IN) LENNOX / LF24-250A 250 —GW— GREASE WASTE 1 - 7 0-520 143-80-2 3/4-3/4 5-8.5 5/16 0-215 HSR 3/4-3/4 6-8 3/16 0-575 B-42R 3/4-1 5.5-9 1/2 x 9/16 521-715 143-80-2 1-1 5-8.5 5/8 216-425 HSR 3/4-3/4 6-8 3/8 576-880 B-31R 1 1/4-1 1/4 4-9 1/2 GENERAL INFORMATION (ALL UNITS): —ST— STORM SEWER I E 716-1100 243-8-2 1 1/4-1 1/4 5-8.5 1/2 426-1050 S-202 1 1/2-1 1/2 5-9 3/8 881-1920 B-34SR 2-2 6-9 7/8 x 1 1. ALL UNITS ARE 115V, 1 PHASE, 60 HERTZ WITH 24V CONTROL TRANSFORMER. E „r 1101-2150 243-8-2 1 1/2-1 1/2 5-8.5 1 1051-2300 S-202 1 1/2-1 1/2 5-9 3/4 1921-3950 B-34R 2-2 5-8 7/8 X 1 2. INSTALL BOTTOM OF HEATER AT ELEVATION INDICATED ON DRAWINGS 6 9 OVERFLOW ROOF DRAIN LINE Call) 2151-4700 243-12-2 2-2 5-8.5 1 1/4 2301-4500 S-202 2-2 5-9 1 3/16 _ UNLESS NOTED OTHERWISE. ei 11 0-375 243-8-2 1 1/4-1 1/4 6-14 1/4 0-175 HSR 3/4-3/4 10-12.5 3/16 0-439 B-42R 3/4-1 8-14 1/2 x 9/16 3. PROVIDE 60 DEGREE DISCHARGE NOZZLE. - DOMESTIC COLD WATER U 376-1175 243-8-2 1 1/4-1 1/4 6-14 1/2 176-330 HSR 3/4-3/4 10-12.5 3/8 440-674 B-31R 1 1/4-1 1/4 8-12 1/2 m 1176-2175 243-8-2 1 1/2-1 1/2 6-14 1 331-950 S-202 1 1/2-1 1/2 10-12.5 3/8 675-1674 B-34SR 2-2 8.5-12.5 7/8 X 1 10.28.11 1::= . a 'R o 2176-4500 243-12-2 2-2 6-14 1 1/4 951-2300 S-202 1 1/2-1 1/2 10-12.5 3/4 1675-3564 _ B-34R 2-2 6.5-13 7/8 X 1 G NATURAL GAS r r 2301-3350 5-202 2-2 10-12.5 1 3/16 PLUMBING VENT WA GENERAL INFORMATION (ALL REGULATORS): 0 GAS PRESSURE REGULATOR 1. MINIMUM INLET PRESSURE, 1.5 PSI; SET OUTLET PRESSURE TO 7 INCHES WATER COLUMN UNLESS NOTED OTHERWISE. 2. VERIFY CAPACITY SHOWN ON PLANS WITH CAPACITY SCHEDULED FOR EACH REGULATOR MANUFACTURER BEFORE ORDERING. CAPACITIES VARY BETWEEN MANUFACTURERS. 3. PROVIDE WITH INTERNAL RELIEF VALVE. C ELBOW - TURNED DOWN * FOR MUNTERS UNIT USE SPRING RANGE TO SET OUTLET PRESSURE AT 11 INCHES OF WATER COLUMN. 0 ELBOW - TURNED UP CONTACT INFORMATION: SENSUS-SENSUS METERING SYSTEM: 1-800-375-8875; FISHER-VINSON PROCESS CONTROLS: 1-888-217-5428; ITRON-MIDWEST GAS EQUIPMENT, INC: 1-877-962-8808. C TEE - TURNED DOWN 05.29.09 —O TEE - TURNED UP PLUMBING FIXTURE SCHEDULE lel BALL VALVE MARK FIXTURE BRANCH SIZES (MIN.) MANUFACTURER CATALOG DESCRIPTION, TRIM AND ACCESSORIES NOTES CW HW _ WASTE VENT NUMBER IOI PLUG VALVE PRV WATER --- --- --- --- WATTS LF223 LEAD FREE BRONZE BODY VALVE WITH SHUT-OFF VALVES FOR SIZES PRESSURE UP TO 2-1/2", CAST IRON BODY FOR 3" AND ABOVE. MAXIMUM D CHECK VALVE REGULATOR OPERATING PRESSURE OF 200 PSI. CONFORM TO ASSE 1003. WILKINS 500XL bC SHUT-OFF VALVE IN VERTICAL LINE GENERAL INFORMATION (ALL FIXTURES): (fi WATER PRESSURE REGULATOR �HENDERSON 1. SUBSTITUTIONS NOT PERMITTED. REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES; ENGINEERSM BACKFLOW PREVENTER B3451ENEXADRIVE,SUITE 300 02.27.15 LENEXA© wxo 913 742 5000 LI2 D 6[ 913 742 5001 WATER/FLOW METER www.hei"eng.com LISTED FLUE CAP I I 1592095935 REF SPECIFICATIONS 0 ROOF DRAIN/OVERFLOW ROOF DRAIN (REZNOR: USE MANUFACTURER'S VENT j M n-.I YCO YARD CLEANOUT CAP OPTION CC1) \ HIGH TEMP —II WCO/CO WALL CLEANOUT/CLEANOUT SEALANT 12" MINIMUM ABOVE S CONNECT TO EXISTING STORM SNOW LEVEL OR PER COLLAR AUTHORITY HAVING JURISDICTION ETR EXISTING TO REMAIN \ 26 GA. MINIMUM • - xl METAL FLASHING COLLAR/INSULATION I z SHIELD BY GAS Z 5 COMPANY • • PROVIDED UNDER Z REF ARCHITECTURALDIVISION 15 10 FOR ROOF PENETRATION (VERIFY) Q AND FLASHING DETAILS i I Z w - � al, � 3 � � � 7 � � _ «-- PRESSURE TEST ^ g �I -I a I �I ' 1" MIN GLASS FIBER FITTING et _ I I�I�I� ' d Ct co it/ INSULATION — — Zr GAS PIPE TOI'lll�l I �Iliii I$I�I�I , I� Z TYPE B FLUE VENT Dili; ADDITIONAL GAS OR AS REQUIRED PER _ METERS AS _ SEAL ALL SINGLE WALL FLUE MANUFACTURER'S SHOWN ON = , I JOINTS AND SINGLE TO INSTRUCTIONS PLANS - I� S ��I, . J LL DOUBLE WALL FLUE VENT SINGLE WALL FLUE m JOINTS WITH MINIMUM RATED UNLESS NOTED _ O -� GAS PIPES UP H 500' F SILICONE ADHESIVE ^^ OTHERWISE ON PLAN € ] it. • EXTERIOR WALL W SEALANT BY GENERAL w�REFER TO UNIT HEATER �..r _ OF BUILDING, C ELECTRIC OR EQUAL w M FLUE VENT SIZING TABLE FOR FLUE SIZES NOT II� #� 41% Ole ONTO NOAND 0 N SHOWN ON PLAN i.. p.. .., 1n SIZE AS SHOWN - = rn TYPICAL BRANCH ��� INI MI im ON PLAN O O Z g 0 WITH GAS TYP OF 3 OE- 0 UNIT HEATER FLUE VENT SIZING TABLE SHUT-OFF COCK r Q LC Oca MANUFACTURER MODEL # FLUE VENT MAXIMUM FLUE w < Z o DIAMETER VENT LENGTH (FT.) _ VIII. ANCHOR RISERS 3 ct REZNOR UDAP-100 35 TO WALL AT TEN Q Q o 0 4" ce a —I P MODINE HD100 5" 25 \ / EXISTING GAS FOOT INTERVALS USING OFFSET LENNOX LF24100A 5" 25 PIPE UP AND REZNOR UDAP-250 5" 50 fr- -r RISER CLAMPS. REVISIONS MODINE PDP250 7" 25 1 THROUGH 1J1 I EXTERIOR WALL CII' TR LENNOX LF24250A 7" 25 E p � J REZNOR UDBP-250 5" 50I UNION INSTALL PIPING SHOWN IN THIS MODINE BDP250 7" 25 I *1 DETAIL TO AVOID CONFLICT WITH TRANE GBND025 7" 25 -_ -_� TEE W/CAPPED UNIT INTERIOR ACCESS FOR -_ I II ��I��� IfI1I ' �II' � TYPICAL GAS 1/8" PRESSURE INSPECTION AND/OR MAINTENANCE FLUE THRU ROOF STRAITYP NNN - `I uu Z SHUT-OFF COCK GAUGE CONNECTION NTS 02.26.10 MM05 PRESSURE REGULATOR PIPE INCREASER y f INSTALL MIN 18" ABOVE ROOF WITH RELIEF TYP -S 1- l J VENT FACING IN THE DOWN POSITION €� Ii ,I�'i 12.23.16 REF GAS PRESSURE REGULATOR SCHEDULE _ �� Ni • - F� PROVIDE 6" LONG 8 uuE UL LISTED BALL GAS VALVE DIRT LEG AT PIPING TO INDOOR REF SPECIFICATIONS; NO -� I _I II% VIIII Oa BOTTOM OF EACH UNIT HEATER SHALL BE INSTALLED GAS EQUIPMENT SUBSTITUTIONS PERMITTED / / AAS imi mpg 1.1 RISERS. CAD WITH INDIVIDUAL FLUE, REF FLUE THRU ROOF / / 1�I ISI uoi of FIE i PROVIDE ONLY MALLEABLE DETAIL FOR SIZE AND REQUIREMENTS PIPE INCREASER 3" FULL SIZE _ � IRON OR FORGED STEEL EXCESS FLOW VALVE (EFV) On g TYPmai,[� SEDIMENT TRAP �Z WELDED TYPE PIPE FITTINGS (WHEN SHOWN ON PLAN) REF FLUE THRU I OVERCALL PER SPECIFICATIONS IN VERTICAL POSITION REF ROOF DETAIL NEW LOW €0] :00 ] = PIPE UNION WITH MECHANICAL ROOF PENETRATION REF ARCH ROOF PENETRATION REF ARCH MANUFACTURER'S INSTRUCTIONS PRESSURE mss` GROUND JOINT ROOF SUPPORT FROM STRUCTURE TYP AND - �__ REGULATOR 3 i �(� I ; , I ; ( — ? i[ i l j l l t l E € 111 REF ROOFTOP GAS ABOVE PER MANUFACTURER'S I��Li� REGULATOR DETAIL-.,,,, RECOMMENDATIONS _ _ Ire • • • • • • • • • • • ROOF _ BEAM CLAMP 2 x 2 x 1/4 'AI \ G i CONNECT NEW PLUMBING Y LOW PRESSURE L ANGLE OR 1 5/8 x 1 5/8 / '� KEEP ASSEMBLY IN SW _ rat 1 I DETAILS SYSTEM 5 PSI METER NEW LOW UNISTRUT TO TOP CHORD \ `-ALL THREAD ROD ROOF JOIST AREA GAS PIPING REGULATOR SET UPSTREAM OF AND PIPING PRESSURE METER OF BAR JOISTS WITH NO PORTION r REF PLAN AT 5 PSI ETR EXISTING 5 PSI ETR ANGLE OR UNISTRUT BELOW BOTTOM SYSTEM MOUNT PIPE WITH U-BOLT -- BALL VALVE B w TO 1 1/2 X 1 1 2 X 1 4 JOIST CHORD OF JOISTS / / / II �� GRADE OR _-1 ANGLE IRON BOLTED TO �� G TYP HANGER PAVEMENT CERIFD REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. r rW ANGLE OR' UNISTRUT SUPPORT PIPING FROM I COORDINATE WITH GAS COMPANY WITH REGARD TO INSTALLATION OF OTHER 24" m STRUCTURE PER PLUMBING UTILITIES IN VICINITY, IF ANY. APPLY FOR AND PAY GAS EXCESS FLOW VALVE SHALL BE: ■i ' - 6" DIRT LEG, END SHALL BE SPECIFICATIONS. REFER OMEGA FLEX FGP-LFD-275B, ABOVE BOTTOM OF HEATER S COMPANY FEES FOR INSTALLATION. USE WELDED OR SCREWED PIPE AND TO PLANS FOR PIPE SIZE. BY OMEGA FLEX, INC. 800-671-8622 FITTINGS PER PLUMBING SPECIFICATIONS. M P O . ROOFTOP GAS REGULATOR 3/4" I.D. FLEXIBLE GAS CONNECTOR LJ ,,,, © NTS 12.26.06 MT01-2 GAS UNIT HEATER CONNECTION GAS METER SETTING - MULTIPLE El 0 NTS 05.27.11 MM09 1110 NTS 0 z a L SEISMIC NOTES GENERAL NOTES 1;.' E1 REFER TO SEISMIC RESTRAINT SHEET SR1 FOR hi 4 INSTALLATION DETAILS. REFER TO THE 1. THE NATURAL GAS DEMAND SHOWN IN CUBIC SPECIFICATIONS FOR FURTHER INFORMATION. FEET PER HOUR (CFH) IS BASED ON A I HEATING VALUE OF 1000 BTU PER HOUR (1 ,'�, g MBH) PER CUBIC FOOT AND SPECIFIC GRAVITY OF 0.6. CONTACT LOCAL UTILITY FOR EXACT r.r. l LOCATION AND SIZE OF GAS METER, GAS A a PRESSURE, SIZE AND TYPE OF PIPING AND r L VALVES REQUIRED FOR CONNECTION TO 1 METER. VERIFY CORRECT GAS PRESSURE a DOWNSTREAM OFSERVICE REGULATOR AFTER N W. GAS UTILITY COMPLETES INSTALLATION. " 2. INSTALL PIPING AT 60" MINIMUM FROM HVAC 4' EQUIPMENT AND PARAPET WALLS. 9 10 a 3. FLEXIBLE DUCTWORK IS NOT PERMITTED. 4. REFER TO STRUCTURAL DRAWINGS FOR EXACT LOCATIONS OF ROOFTOP EQUIPMENT. 1 I f 5. LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE OVER DIFFUSER AND GRILLE LOCATIONS. , LOCATE DIFFUSERS AND GRILLES TO I I ACCOMMODATE LIGHTING LAYOUT. DO NOT I j INSTALLDUCTWORK OR EQUIPMENT DIRECTLY SKYLIGHT t UNDER WELLS UNLESS NOTED "`.......... C OTHERWISE ON PLANS. 1 REF S HIT-2 - G b j ( 6. DUCT SIZES SHOWN ON DRAWINGS ARE NET 1—MPO1.2 th101 1 FREE AREA. INCREASE RECTANGULAR SHEET ILL BREAKROOM CD METAL SIZE AS REQUIRED FOR LINER. REFER r� j �� TO SPECIFICATIONS FOR THE INSULATION 200 THICKNESS. T[ `° 11 I S 1 1/4 DUCTWORKCTWORK FOEQUIVA�NT FR EOAREAUMAY 11 RTU2 �\ BE USED IN LIEU OF RECTANGULAR. 11 \\ 48"AFF� i i f£ 7. DUCT SUPPORT AND GRILLE DETAIL IS [ _ T -- J L of I APPLICABLE THROUGHOUT THE STORE. DO HENDERSON • 3 s„OF �— ftJi1 I NOT ENGINEERSiO ,i DECKU.SE FASTENERS THAT PENETRATE ROOF B345lfNEXADRIVE,SUITE 300 ON ROOF 1 ' , I ,- LENEXA,KS66214 8. TYPICAL BRANCH DUCT FITTING DETAIL IS wxo9137425000 m[ 913 12/10 ' 12/10 APPLICABLE THROUGHOUT THE STORE. www.hei-eng.com I TOILET �_� i • \— \— 1592095935 /�! `CD 1 I I 6 9. PROVIDE VOLUME CONTROL DAMPERS IN \ 200 " M� _ DUCTS TO DIFFUSERS. INSTALL DAMPERS A \^ ` �iZT, I MP23.2 \^/ CD MINIMUM OF 24" AWAY FROM DIFFUSERS AND in 1 ` — J A MAXIMUM OF 60" ABOVE THE CEILINGS FOR r -----J RAG RTU2 TYP �\ 200 EAG1 ACCESSIBILITY UNLESS SHOWN OTHERWISE ON g" 116" 105 MBH DRAWINGS. PROVIDE ACCESS PANELS WHERE CD (D ----1 6" t„ . 75 _1 i TYP OF 3 I i DAMPERS MUST BE INSTALLED ABOVE 8" L. . ; C I 1 NON-ACCESSIBLE CEILINGS. REFER TO 100 re', j VOLUME/BALANCE DAMPER SCHEDULE FOR APPROVED MANUFACTURERS. TOILET 11 — HALLWAY C �� 10. INSTALL EXHAUST FANS A MINIMUM OF 10 FT CD1 ' `� de FROM OUTSIDE AIR INTAKE OF ROOF TOP U) F �/ UNITS. INSTALL EXHAUST FANS AND ROOFTOP 1"- 50 509 \\\ I EDGE UOR A MINIMNITS A UM OFMUM 6F 1FOT FROM FT OPARAPET z € TYP OF 2 � ` ' I WALLS THAT ARE AT LEAST 42" HIGH. Z I 11. LABEL RTU'S WITH 6 IN BLACK PERMANENT W I PAINT STENCIL. NUMBER UNITS AS INDICATED ON DRAWINGS. LOCATE LABEL FOR EACH I- 3/4"/ MP23 2 UNIT SO IT CAN BE READ FROM THE ROOF O N 1 i HATCH. Z LL TYP )-< --Ti 12. PROVIDE START—UP ASSISTANCE FOR ALL•I 0Z 0 GAS—FIRED EQUIPMENT INCLUDING BUT NOT LL— LIMITED TO ROOF TOP UNITS AND UNIT 8 ___ _—________...._._............................... .... .21 HEATERS. COORDINATE ADJUSTMENT OF - I Er REGULARS WITH SET—UP PERSONNEL T E� �� ENSURETCCORRECT GAS FLOW PRESSURES OFOR m 0 `� Irl PROPER OPERATION OF ALL EQUIPMENT H i. 12/10 W I 13. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE __I AND BECOME FULLY ACQUAINTED WIN THE 0 co N RTU1 I EXISTING CONDITIONS OF THE PROJECT. O = N 2 1 150 MBH 1 EXISTING CONDITIONS WERE TAKEN FROM D rn — 1 ORIGINAL DRAWINGS AND MAY NOT REFLECT F- 0 O z • TYP �� EXACT AS-BUILT CONDITIONS. COORDINATENEW WORK AND R O 8 RAG € ,1 I ' I I DISCIPLINES ANDD EXISTING CONDITIONS EMOLITION WITH EPRIOR D o o ©� I ` TO CONSTRUCTION. w < Z 18" 1• H I I TYP TYP f ( a J r= , I FUME L J f fi Srr ! f 200 TYP OF 7 j _ _ 3 t ! f TENANT „16/12 EE X WE [ m 3 ( 12.23.16 WM N0. 3 f X I-- ( \ K CD [quo FILEj 250 SC tme lt VERIZON WIRELESS I MECHANICAL am i f RTUI I PLANS 48 AFF ____ �_ __ ? ` I aaffam:, ..... 9 > 1BC[[ TT t f ........____._......_..... ° _£ 111���L��l 1 / jj V-��-~t j : ! 1 MECHANICAL PLAN MP22 . 2 W J 0 I Z c w fn t. TOP BEAM t 3" CLAMP TYPROOFTOP UNIT SCHEDULE LENNOX SG SERIES MECHANICAL SYMBOLS MAX TOP CHORD OF JOIST ROOF . 3 ROOF MARK AREA NOMINAL SUPPLY FAN GAS HEAT SMOKE NOTES RECTANGULAR DUCT 18" WIDE A SERVED CAPACITY OUTSIDE INPUT DETECTOR + 18/12 BY 12" DEEP �� (TONS) CFM ESP AIR CFM OPERATION (MBH) LOCATION 7� °� 2"x2"x1/4" ANGLE OR RTU1 VERIZON WIRELESS 5 1650 0.5" 165 AUTO 150 --- '�� 6 / 1 5/8"x1 5/8" UNISTRUT 6„ RTU2 VERIZON WIRELESS 3 1200 0.5" 120 AUTO 105 --- 12" 12" DIAMETER ROUND DUCT -17111 DUCT HANGER STRAP GENERAL INFORMATION (ALL UNITS): ' REF SPECIFICATIONS 1. UNIT IS 208V, 3 PHASE, 60 HERTZ. UNITS MUST BE UL OR ETL AS WELL AS AGA APPROVED. MINIMUM AFUE = 80% >< SUPPLY DUCT IN SECTION �, R La 2. UNIT OPERATING WEIGHT (LBS): 5 TON = 1087, 3 TON = 1063. n _L —L 3. OUTSIDE AIR IS CONDITIONED THROUGH THE ROOFTOP UNIT AS SCHEDULED ABOVE IN ACCORDANCE WITH ASHRAE 62.1-2007. RETURN OR EXHAUST DUCT IN LNI10) 5U LOADS MUST BE 4. HACR—TYPE RATED CIRCUIT BREAKER. c:, 5 SECTION PCIHUNG WITHIN 3" BOTTOM OF „ 1" MIN. 5. SINGLE POINT POWER AND GAS ENTRY CONNECTIONS. ,o OF PANEL POINTS STRUCTURE SHEET METAL o REF STRUCTURAL SCREWS TYP 6. ROOF CURB AND ANCHOR BRACKETS FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. REFER TO1% THREADED ROD 7. SPECIFICATIONS AND HVAC SEISMIC/WIND RESTRAINT BRACKET DETAIL. RECTANGULAR RADIUS ELBOW ISIMIIMIlal TYP 60" MAX. 4, UNIT ENERGY EFFICIENCY RATING (EER) PER ARI 210 & 360 ARE AS FOLLOWS: 3 TON = 13.6, 5 TON = 12.8. mk 8. UNIT SEASONAL ENERGY EFFICIENCY RATING (SEER) PER ARI 210 & 240 ARE AS FOLLOWS: 3 TON = 16.1, 5 TON = 15.5. RECTANGULAR DUCT 2"x2"x1/4" ANGLE OR 9. PROGRAMMABLE THERMOSTAT IS FURNISHED SEPARATELY BY LENNOX AND INSTALLED BY CONTRACTOR. RECTANGULAR TEE RECTANGULAR DUCT 1 5/8"x1 5/8" UNISTRUT RECTANGULAR DUCT 10. MAKE FINAL COMPRESSOR WIRING TERMINATIONS ON ROTATION—SENSITIVE COMPRESSORS.PERPENDICULAR TO STRUCTURE PARALLEL TO STRUCTURE 11. FULLY MODULATING ECONOMIZER.12. FACTORY INSTALLED CONVENIENCE RECEPTACLE. ROUND (OR OVAL) ELBOW LOADS MUST BE 13. HIGH PERFORMANCE FULLY MODULATING ECONOMIZER. tttt���� HUNG WITHIN 3" BEAM CLAMP OPTIONAL ROUTING VOLUME/BALANCE DAMPER OF PANEL POINTS IN CONCEALED /DUCT HANGER STRAP 07.27.12 3" REF STRUCTURAL AREASREF SPECIFICATIONS ROOF MAX ROOF AIR DEVICE SCHEDULE 0741 SUPPLY AIR DIFFUSER WITH MARK SERVICE MANUFACTURER STYLE FRAME TYPE FACE SIZE NOTES ROUND SUPPLY DUCT I / MODEL RETURN OR EXHAUST AIR DIFFUSER / CD SUPPLY AIR TUTTLE & BAILEY E.H. PRICE CARNES ROUND NECK LAY—IN 24 X 24 A, C, D gi WITH ROUND DUCT \ 6" / 6111, S1200 SCD SFTB CEILING DIFFUSER / CD1 SUPPLY AIR TUTTLE & BAILEY E.H. PRICE CARNES SQ / RETANGULAR SURFACE REF A, C, D, F, G CD DIFFUSER OR GRILLE TYPE M SMD SKFA CEILING DIFFUSER MOUNT DRAWINGS —L _L 12" BRANCH DUCT AND/OR NECK SIZE BOTTOM OF CTURE _� RAG RETURN AIR TUTTLE & BAILEY E.H. PRICE CARNES 1 2'x1/2"x1/2" LAY—IN 24 X 24 B, C, D, E 450 CFM RESTFSPECIFICATIONSti° A 2"x2"x1/4" ANGLE OR / C DUCT HANGER STRAP J ` 1 5/8"x1 5/8" UNISTRUT CRE500 SOTB RAPAH EGGCRATE OT RTU1 THERMOSTAT HENDERSON CEILING GRILLE `� I DUCT SUPPORT BAND EAG1 EXHAUST AIR TUTTLE & BAILEY E.H. PRICE CARNES 1/2"x1/2"x1/2" SURFACE 12 X 12 B, C, D, F, G ��ENGINEERS ROUND SUPPLY l� Illirlir �O g6 SAME SIZE AS STRAP CRE500 SOF RAPAF EGGCRATE MOUNT AIR DUCT LOAD RATED 6 CEILING GRILLE 8345 LENEXA DRIVE,SUITE 300 FASTENERS 2 / LENEXA,K566214 kxo VOLUME/BALANCE DAMPER SCHEDULE 913 SD[ 913 742 5001 SUPPLY REGISTER, REF FLOOR PLAN / TYPE MANUFACTURER MODEL NOTES www.hocom 1592009593595935 FOR SIZE AND LOCATION, MOUNT ROUND AES WMVCD REGISTERS © 30 DEGREE ANGLE IN STOCKROOM RECTANGULAR AES AMD4 AREA AND 15 DEGREE ANGLE IN SALES AREA, ROUND SUPPLY EXCEPT THOSE SHOWN ON BOTTOM AIR DUCT 1. THIS SCHEDULE IS COMPREHENSIVE. ALL MARKS MAY OR MAY NOT BE USED ON THE PLANS. OF DUCT ON THE PLAN 2. DIFFUSERS TO BE INSTALLED IN REFERENCE TO BOTTOM OF GRILLE UNLESS NOTED OTHERWISE. PERPENDICULAR TO JOIST PARALLEL TO JOIST NOTES: DUCTSUPPORT AND GRILLE A. ALL STEEL CONSTRUCTION. 6B. ALL ALUMINUM CONSTRUCTION. NTS 04.24.09 MMOL C. BRANCH DUCT SIZE SHALL BE SAME AS NOTED DIFFUSER NECK SIZE UNLESS NOTED OTHERWISE. D. STANDARD WHITE FINISH. E. PROVIDE WITH NECK FOR DUCT CONNECTION. (n L L = W/4, 4" MIN F. PROVIDE WITH MANUFACTURER'S OPPOSED BLADE DAMPER IN NECK. I— REF PLANS FOR 03/16 G. PROVIDE WITH CEILING ROUGH—IN TRANSITION BOX TO BE FRAMED IN CEILING JOIST SPACE. z O� OII � RUNOUT SIZES SCREW HOLES F� F, - FOUR PER ROW 10.31.14 Q �Q A �`� BRACKET HVAC UNIT Z P P /�I' _i EQ SPACED TYP is or --T. ND, #12 TEK ......IW (TYP EIGHT FAN SCHEDULE zz SCREWS � 0 O k // PER BRACKET) MARK AREA MANUFACTURER CFM ESP MOUNTING V/PH/HZ DRIVE CONTROL Z a.L CURB 10 GA _� SERVED MODEL FAN TYPE HP (W) METHOD SPIN—IN FITTINGS W/ SCOOPS GALV TYP CHOOSE TOP OR EF1 VERIZON WIRELESS CARNES GREENHECK ACME PENNBARRY 150 0.15" ROOFTOP 120/1/60 DIRECT WALL SWITCH Y j ARE NOT ACCEPTABLE L BOTTOM ROW RESTROOMS VEDKO6F3 G-065—D PRNO80-1 DX08R CENTRIFUGAL 1/10 2 �/ ROOF 18 GA m 45' LEAD IN GALV STRAP GENERAL INFORMATION: Q O BRACKET ATTACHMENT LENNOX RTU BRACKET TYP 1. FANS MUST BE UL OR ETL LISTED. W © BRANCH DUCT FITTING 2. ALL FANS EXCEPT FOR OVERHEAD CIRCULATING FANS MUST BE AMCA CERTIFIED. BRACKET A. FURNISH WITH FACTORY MOUNTED DISCONNECT. I- M 0 co NTS 08.13.01 MM25 TYP B. FURNISH WITH GRAVITY BACKDRAFT DAMPER AND BIRDSCREEN. O N = C. ROOF CURB PROVIDED BY GENERAL CONTRACTOR. REFER TO SPECIFICATIONS. F— L.1.. =O cm Z 3 & 10 TON D. FURNISH WITH FACTORY PRE—WIRED FAN SPEED CONTROLLER. Q 2 0 c5 TON , E. FASTEN THE BASE OF EQUIPMENT TO ROOF CURB WITH (8) #10 SET SCREWS AND NEOPRENE / SS BONDED WASHERS (2 PER SIDE). O ,_I 1- 0 • POINT SHOULD BE w Q o 0 DIRECTLY ABOVE CENTER IA „/' 04.26.12 1.-- Q NLIFTING F GRAVITY C 5 --STYLE PICK '� tl ' ri LENNOX RTU BRACKET LAYOUT/ ROUTEPIPINGPE TO ALLOWOW FULLLLOPENING BRACKETS ARE FURNISHED WITH ROOF CURBS. BRACKET CONSTRUCTION, QUANTITIES, AND SPACING SHOWN ON THIS DETAIL IS OF ALL EQUIPMENT 1!!!!IIIC FOR GENERAL COORDINATION ONLY. INSTALL BRACKETS ACCORDING TO CURB MANUFACTURER'S INSTALLATION INSTRUCTIONS. ACCESS PANELS. COORDINATE FINAL BRACKET LOCATIONS WITH EQUIPMENT. DO NOT OBSTRUCT OPENINGS OR UTILITY CONNECTIONS. IF UNION CENTER OF TEE W/CAPPED 1/8" GRAVITY HVAC SEISMIC/WIND RESTRAINT BRACKET PRESSURE GAUGE 4 NTS 06.27.08 MM28 CONNECTION DATE ROOFTOP I 12.23.16 GALVANIZED PIPE STAINLESS STEEL UNIT BORA[p STRAP. FIT TIGHT ADJUSTABLE HOSE CLAMP TO PIPE. (BOTH SIDES) GAS LINE PAINTEDGALVANIZED PIPE STRAP ONECOD FluREF ARCHSIZE LARGER THAN PIPE BALL GAS RUBBER WALKPAD _—GAS LINE PAINTEDfVALVE BLOCKNREF OGTDETAIOP LE srmv1104411111111111111."-111111.14 II ADHERED TO ROOF A I�II�I REF ARCH ^ REF ARCH 3" FULL SIZE !i f,-J VERIZON V L RUBBER WALKPAD SEDIMENT FOR INFORMATION ONLY, REFER TO MANUFACTURER'S INSTRUCTIONS. " ROOF MEMBRANE ADHERED TO ROOF _—_ TRAP _ WIRELESS trawl -1111±,1=—ROOF" INSULATION $1 ;;€ REF ARCH u Mai MECHANICAL NOTES: ROOF MEMBRANE �.� • ROOF 1. DETACH WOODEN BASE PROTECTION BEFORE RIGGING. 1 1/2" ZINC COATED ROOF INSULATION SCHEDULES 2. RIG UNIT FOR LIFTING BY CONNECTING RIGGING TO THE UNIT BASE LAG SCREWS TYP N z USING BOTH HOLES IN EACH CORNER. ATTACH FOUR CABLES TO 1 1/2" ZINC COATED AND DETAILS HOLES IN UNIT BASE RAIL, SEE FIGURE. CRANE AND RIGGING MUST BE TREATED WOOD BLOCKING: LAG SCREWS TYP CAPABLE OF HANDLING WEIGHT LISTED IN MANUFACTURER'S PUBLISHED St 6X6X12 FOR GAS PIPING A INFORMATION. 8'-0" OC MAX TREATED WOOD BLOCKING: 60" MIN 3. ALL PANELS MUST BE IN PLACE FOR RIGGING. DO NOT ADHERE TO PAD 6X6X12 FOR GAS PIPING BCRA_ e. 4. PLACE FIELD—PROVIDED H—STYLE PICK IN PLACE JUST ABOVE TOP 8'-0" OC MAX DO NOT =— EDGE OF UNIT. FRAME MUST BE OF ADEQUATE STRENGTH AND "'' ADHERE TO PAD C os a=te, .«R ..�EA Eo LENGTH. (H—STYLE PICK PREVENTS DAMAGE TO UNIT.) AT ROOFTOP EQUIPMENTr 5. LIFTING POINT SHOULD BE DIRECTLY ABOVE CENTER OF GRAVITY. PIPE DIAMETER LESS THAN 2" PIPE DIAMETER 2" OR GREATER cy LENNOX RTU RIGGER ROOF TOP PIPE BLOCKING GAS CONNECTION /SUPPORT MP23 . 2 W N © NTS 01.28.05 0 NTS 01.28.05 MT07 NTS 01.28.05 MT01-1 w 0 z LA CO ti PLUMBING SYMBOLS let 3 gi _ PLUMBING FIXTURE SCHEDULE ti 3 MARK FIXTURE BRANCH SIZES (MIN.) MANUFACTURER CATALOG TRIM AND ACCESSORIES NOTES —SS— SANITARY SEWER CD— CONDENSATE DRAIN 0 WATER/FLOW METER 5d CW HW WASTE VENT NUMBER gp —GW— GREASE WASTE PLUMBING VENT WHA WATER HAMMER ARRESTOR WC8 WATER CLOSET 1/2" --- 4" 2" TOTO CST744EL 1.28 GPF FLUSH TANK W/ LOCKING COVER 6 g HANDICAPPED AMERICAN 215AA.104 ELONGATED SEAT: BEMIS 1055SSC, MAINLINE ML 1055SSC -1 (TANK) STANDARD SUPPLY LINE: STAINLESS STEEL BRAIDED HOSE, — DOMESTIC COLD WATER —SIF-- UNION A T & P RELIEF VALVE a, N us (FLOOR MOUNT) 1/4 TURN BALL VALVE STOP. �-{_ CAST IRON FLOOR FLANGE: ZURN CF-2984-CI4, TYLER 2-252TS, ---- DOMESTIC HOT WATER 0 GAS PRESSURE REGULATOR T TMV THERMOSTATIC MIXING VALVE i WITH "NO SEEP" WAX RING AND BRASS ANCHOR BOLTS. (11) q e — ----- DOMESTIC HOT WATER RETURN GAS COCK O FD1 FLOOR DRAIN L2 LAVATORY 1/2" 1/2" 1 1/2" 1 1/2" SLOAN SS-3003 FAUCET: TOTO TEL3LS-10 — 0.5 GPM SENSOR OPERATED SELF— A, B �— i g. TOTO LT307.4 GENERATING POWER SYSTEM, STANDARD SPOUT, 4" COVER T TEMPERED WATERR o PLATE, GRID STRAINER WITH TAILPIECE, P-TRAP WITH CLEANOUT, C ELBOW - TURNED DOWN 0 ROOF DRAIN STOP VALVES, SS BRAIDED WATER SUPPLIES AND G NATURAL GAS ESCUTCHEONS. PROVIDE THERMOSTATIC MIXING VALVE FOR L2. o-- ELBOW - TURNED UP —O FCO FLOOR CLEANOUTSEAL CARRIER: JOSAM 17100, WADE W-520. LAVATORY ENCLOSURE: TRUEBRO LAV-SHIELD 2018 IjI BALL VALVE TEE - TURNED DOWN --0 YCO YARD CLEANOUT L2 ASSE 1070 THERMOSTATIC MIXING VALVE: ZURN ZW387OXLT 101 PLUG VALVE TEE - TURNED UP ��FPWH FREEZE PROOF WALL HYDRANT EWC1 ELECTRIC WATER 1/2" --- 1 1/2" 1 1/4" OASIS HALSEY TAYLOR STAINLESS STEEL TOP AND CABINET, FRONT AND SIDE PUSH BARS, LEAD A COOLER (SINGLE) PG8AC HAC8FS-Q ADA FREE, WATER SAVER BUBBLER WITH FLEXIBLE BUBBLER GUARD (FOR CHECK VALVE O WATER PRESSURE REGULATOR -F HB HOSE BIBB HALSEY TAYLOR - SMARTFLOW BUBBLER KIT), STOP VALVE, 3/8"X1/2" SS BRAIDED WATER SUPPLY, P-TRAP WITH CLEANOUT AND ESCUTCHEON. FCC SHUT-OFF VALVE IN VERTICAL LINEBACKFLOW PREVENTER —lI WCO/CO WALL CLEANOUT/CLEANOUT CARRIER: JOSAM 17560-WC, WADE 400-AM11. GENERAL INFORMATION (ALL FIXTURES): 1. P-TRAP SOP WITH CLEANOUT AND SINKEU CONTINUOUS WASTES: POLISHED CHROME-PLATED TUBULAR S R BRA ,17 GAUGE, WITH BRASS- BRASS NUTS AND SLIP INSERTS. - SS BRAIDED WATER SUPPLY: FLEXIBLE BRAIDED STAINLESS STEEL (SS) OUTER SHEATHING WITH REINFORCED PVC INNER TUBING. DRAIN / CLEANOUT SCHEDULE - STOP VALVES: CHROME PLATED BRASS, QUARTER TURN ANGLE STOP VALVES. MARK DESCRIPTION NOTES: MANUFACTURER MODEL NUMBER A. INSTALL 1/2" X 3 3/4" STAINLESS STEEL SIMPSON WEDGE-ALL WEDGE ANCHORS FOR ALL FIXTURE CARRIERS. FLOOR AND ROOF DRAINS B. INSTALL THERMOSTATIC MIXING VALVE. FD1 LIGHT DUTY ADJUSTABLE PVC WITH THREADED ADAPTER AND 5" DIAMETER NICKEL BRONZE RING AND 04.24.15 FASTENED GRATE. SPECIALTY PLUMBING FIXTURE SCHEDULE 04SIOUX CHIEF 842 JOSAM VEF 400J OATEY 72000 ri NG NEERSM .24.15 MARK FIXTURE FIXTURE DESCRIPTION 8345 LENEXA DRIVE,SUITE 300 MANUFACTURER/CATALOG NUMBER LENEXA,KS66214 WHA WATER HAMMER ARRESTOR LEAD FREE CONFORM TO PDI WH-201, ANSI A112.26.1M, ASSE 1010. wxo9137425000 ID 913 742 5001 www.hei-eng.com 1592095935 JOSAM SERIES 75000 PRECISION PLUMBING PRODUCTS STAINLESS STEEL #316 SERIES WATTS SS SERIES WILKINS MODEL 1250XL SERIES JAY R. SMITH HYDROTROLS SIOUX CHIEF HYDRA-RESTER MIFAB MWH --- VALVES LEAD FREE FULL PORT BRASS BALL VALVE WITH PLASTIC JACKETED LEVER TYPE HANDLE. RED-WHITE 5044AB OR 5049AB APOLLO SERIES 7OLF CRANE LF9210 SERIES WATTS LF-FBV-3C OR LF-FBVSNEHCO FP-600-A-LF TRAP PRIMER LEAD FREE PROVIDE ALL BRONZE PRIMER VALVE WITH REMOVABLE OPERATING PARTS, INTEGRAL TAP-OFF FROM A LINE CW LINE SERVING A FREQUENTLY (SINGLE TRAP) VACUUM BREAKER, AND GASKETED ACCESS COVER. USED FIXTURE e1 TRAP PRIMER PRECISION PLUMBING PRODUCTS PRIME-RITE OR OREGON #1 SIOUX CHIEF 695 i I W/ VACUUM BRKR. --- TRAP PRIMER LEAD FREE PROVIDE ALL BRONZE PRIMER VALVE WITH REMOVABLE OPERATING PARTS, INTEGRAL I ZURN Z-1024-2 (MULTIPLE TRAPS) VACUUM BREAKER, GASKETED ACCESS COVER, AND MULTIPLE TRAP CAPABILITY i FIXED AIR GAP PRECISION PLUMBING PRODUCTS PRIME-RITE OR OREGON #1 MIFAB M-500NPB JOSAM 88300 SIOUX CHIEF SERIES 695 6" MIN I DISTRIBUTOR CO --- TRAP PRIMER IN-LINE FLOOR DRAIN TRAP SEAL. (WATERLESS) FLOOR IF REQUIRED `. ......J SURE SEAL SS4009 JAY R. SMITH 2692 04.26.13 4 " " ; z G a 4 Q Z _ WATER HEATING SYSTEM SCHEDULE WATER HEATERS I STORAGE TANKS — ��� 1/2" CW TYP H MARK AREA MANUFACTURER MODEL MODEL # TANK HEAT V/PH/HZ NOTES O N SERVED SIZE (GAL) INPUT Z LL WH1 VERIZON WIRELESS A.O. SMITH PREFERRED DEL-20 20 2 KW 208/3/60 A, B, C ((�� Z 0 RHEEM COMMERCIAL ELDS20 Y , EXPANSION TANKS ll ..). \ E1 MARK MANUFACTURER/MODEL MANUFACTURER/MODEL DESCRIPTION MIN. 2" WATER 2 f ETA AMTROL/ST-12 WATTS/PLT-12 FIXED BLADDER TYPE EXPANSION TANK. 4.4 GALLON MINIMUM \ SEAL, MAX. 4" m FLEXCON/WH-18 WILKINS/XT-18 TOTAL CAPACITY, FACTORY STANDARD PRECHARGE CAPACITY. 0 GENERAL INFORMATION (ALL UNITS): I- 1. PROVIDE INCO-LOY HEATING ELEMENTS FOR ELECTRIC WATER HEATERS. IC 2. PROVIDE ASME TEMPERATURE AND PRESSURE RELIEF VALVE FOR ALL WATER HEATERS AND STORAGE TANKS. DETAILS AND DIMENSIONS SHOWN ON THIS DETAIL ARE GENERIC. INSTALL H 0 N 3. PROVIDE VACUUM RELIEF VALVES FOR ALL BOTTOM-FED WATER HEATERS AND STORAGE TANKS. TRAP PRIMERS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. O N F N A. PROVIDE EXPANSION TANK ETA. TRAP PRIMER DETAIL 0NOTES: I- 0 0 Z B. 140 'F OUTLET TEMPERATURE. © J ¢ i NTS 09.30.11 MP62 H C. PROVIDE NON-SIMULTANEOUS, DUAL-ELEMENT OPERATION. SCHEDULED KW IS FOR INDIVIDUAL ELEMENT. F W o O Q 07.27.12 L � ztow SQUARE WASHER THRU BOLT TYP a< J n F & HEX NUT INSTALL WITH MINIMUM 6" ALL THREAD ROD TYP ,, CLEARANCE TO BUILDING ; MOMS STRUCTURE ABOVE PROVIDE AUTOMATIC REFERENCE ONLY FOR 6 INCH PIPE AND INSTALL ASME TEMPERATURE FENDER WASHER & HEX NUT ii IF REFER TO SPECIFICATIONS ABOVE TOP OF HEATER VACUUM RELIEF VALVE NOT APPROVED WITH THIS PERMIT r ckidr PIPINGLARGER, USE THRU BOLTJ \ / AND PRESSURE RELIEF VALVE ^ CHECK VALVE BRACKETCONNECTION, WHEREFURNISHED LIE WATER I 1 POSSIBLE. USE TRAPEZE \ . �f HEATER ��SHUT-OFF VALVE Th _ INSULATION HANGER WHERE JOIST WEB r 1— PIPING CONFLICTS WITH THRU BOLT\ / THERMOMETER - �� SECTION AA _ COLD WATER SUPPLY TOP BEAM PROVIDE A HARD COPPER —----HOT WATER TO FIXTURES INSULATION RELIEF VALVE DISCHARGE ���' PIPING SHIELD C-CLAMP TYP PIPE FULL SIZE OF VALVE �------3/4" BRANCH TO cr' BRACKET `. 3" / y3" 24" 6" OUTLET -+H EXPANSION TANK COLUMN OR DATE TYP MAX/ IMAX MIN MAX fl A DECK TYP ELECTRIC WATER HEATER PER SPECIFICATIONS AND/OR f PARTITION 12.23.16 _w L �� A / PROVIDE 12"WIDE x 12"DEEP r i ���>l r N ri, -- SCHEDULE------- HEAT TRAP AT INLET AND AS SHOWN �� H OUTLET (TYPICAL) �, 3/8" ALL �:vl DRAIN VALVE WITH HOSE BCRA NO. ON FLOOR THREAD ROD A BIBS BY WATER HEATER PLAN n 1 `z, INSULATION �' •y ©� MANUFACTURER f"el, el in � // PIPING ■_ PROVIDE 6" DEEP CLEANOUT COVER r CLEANOUT CADD FIE �� �, �VV7 INSULATION / POINTS TYPJOIST `� � ROOF FLASHING I I HEIGHT ABOVE ROOF RUST-PROOF WATER-TIGHT PAN UNDER UNONDE AT TANKCONN CONNECTIONS IC PIPE WHERE CLEANOUT FABECE WITHINLL SHEET IRIE SHIELD m SHALL EXCEED LOCALTEE IS CONCEALED . xHEATER, WITH DRAIN PIPE , FOR CONNECTION OF 25"x2.5" .25" ANGLE OR VERIZON CLEVIS TOP CHORD OF JOIST MAXIMUM SNOW DEPTH DISSIMILAR METALS (TYPICAL) IN A CHASE OR 4" OF WALL 1 5/8"x1 5/8" UNISTRUT HANGER (CONTRACTOR SHALL PROVIDE PLATFORM. PARTITION SURFACE. MAINTAIN VISIBLE VERIFY), 12" MINIMUM. ATTACH TO BACKBOARD ROUTE RELIEF VALVE PROVIDE WIRELESS CLEARANCE BETWEEN PIPE ROOF AND/OR SUSPEND FROM IF CEILING EXISTS, DISCHARGE PIPE AND Pn EXTENSION I �___________..__ PLUMBING AND JOIST MEMBERS TYP a auSTRUCTURE ABOVE, MINIMUM INSTALL ABOVE IT IF DRAIN PAN PIPE IF REQUIRED , 6" CLEAR OF CEILING, IF ANY _ THERE IS ADEQUATE SEPARATELY TO SCHEDULES ,• DISCHARGE INTO RECEPTOR ° NOTE: --, ,- SPACE AND EASY a4 -, ACCESS SHOWN ON PLAN, WITH AIR d a q 1. UTILIZE FOR ALL PIPING EXCEPT SPRINKLER, ROOF DRAIN, AND REFRIGERATION PIPING. GAP PER LOCAL CODE AND DETAILS 2. SPACE HANGERS AND SUPPORTS IN ACCORDANCE WITH SPECIFICATIONS. REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT 3. LOCATE HANGERS WITHIN 3 INCHES OF JOIST PANEL POINTS U.N.O. SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. VERIFY CONNECTION SIZES AND FLOOR �� 4. DO NOT SUPPORT PIPING FROM BOTTOM CHORD OF BAR JOISTS. LOCATIONS PER MANUFACTURER'S REQUIREMENTS. REFER TO FLOOR PLANS FOR PIPE SIZES. SLAB ...... COMBINATION BCRA iii 5. LABiii5. INDIVIDUAL PIPES 3 INCH AND SMALLER NOT REQUIRED TO BE WITHIN 3 INCHES OF PANEL POINT. PROVIDE SEISMIC STRAP OR BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES AND/OR SEPARATE COMBINATION DETAIL. PLATFORM SHALL BE PLYWOOD ON UNISTRUT FRAME BRACKETED AND ANCHORED TO WALL, WYE AND EIGHTH 6. FOR PIPE RUNNING PARALLEL TO JOISTS, ATTACH TRAPEZE BEAM CLAMPS TO JOISTS ON EACH LONG SWEEP AT END OF LINE AND/OR SUSPENDED FROM STRUCTURE ABOVE WITH THREADED ROD. POWER WIRING AND BEND IN RUN SIDE OF PIPE TYP. ■ ■ OR COMBINATION WYE Air DISCONNECT SWITCH ARE SPECIFIED BY ELECTRICAL. 7 COPPEREPHP SGERS FULLAOD WATER (37.62ALL THREAD ROBS/FDS T) ORE ZED EQ EQUIVALENT.CARRY FMAX) 6 - 3 INCH OAD EXCEEDS MAXIMUMER JOIST EIGHTH PIPE EIGHTH BEND IN DIRECTION ELECTRIC WATER RUN OF LINE CONTACT THE EOR FOR PROPER SIZING. CLAMP TYP OF FLOW Li VENT THRU ROOF ( VTR ) HEATER OVERHEAD WALL CLEANOUT VENT J PIPE SUPPORT NTS 04.27.12 MP65 d W T NTS 11.18.08 MP55 © NTS el NTS 04.27.12 MP64 0 Z C Li N I •`I 0 eg .—" ` •- ta , i. 9 ; • I yy1I i SEISMIC JOIST SEISMIC CABLE M N!e!� g ATTACHMENT BRACE TYP c, _ T HARDWARE TYP lih 1r1 Cli) �III�I� % :V`' RODTMTYPAD f'I r %n SEISMIC JOIST rzcz m - �I'I ATTACHMENT 1 J:_ _ / HARDWARE E a / / y ` AIRCRAFT CABLE �vt: III LOCATION A // EQUIPMENT RBY SEISMIC ESTRAINT CALLTHREAD ROD EISMIC JOIST MANUFACTURER SEISMIC SOLID ATTACHMENT HARDWARE TYP // SEISMIC CABLE BRACE WITH 4"x4" WOOD BLOCK TO PROVIDE BRACE HOOK ONLY SHOWN IN TWO RIGID CONNECTION BETWEEN WATER j— / HEATER AND WALL (TYP) ALLTHREAD / DIRECTIONS FOR CLARITY. �; ROD TYP / ADDITIONAL BRACING IS UPPER STRAP SHALL BE / REQUIRED AS SHOWN IN - LOCATED TO ,THIN JI / PLAN VIEW BELOW. DIMENSIONPR1/30OF F WVERTICAL SEISMIC CABLE BRACE WITH / ' J L AIRCRAFT CABLE HOOK ONLY SHOWN IN ONE / s' HEATER. DIRECTION FOR CLARITY. / 5/8" SEISMIC ANCHOR BOLT BY SEISMIC STEEL BRACE RESTRAINT ADDITIONAL BRACING IS / TO ATTACHED 4"x4" WOOD 45'±15' MANUFACTURER REQUIRED AS SHOWN IN / BLOCK TO HORIZONTAL , `1 PLAN VIEW. / y. METAL STUD (TYP) ( . % `;' V'% III LOWER STRAP SHALL BE O iitraC�� LOCATED TO WITHIN LOWER/ • 1/3 OF VERTICAL4" DIOVE SION WATER EXHAUST HOOD / ��� OF WATER HEATER AND A / ?\IT5H MINIMUM OF 4" ABOVE WATER / �1i��� I HEATER CONTROLS A DI / c.jjr -- PIPE CLAMP MAY BE iENDERSON/ ROTATED TO GAIN ACCESSIITO STRUCTURE ABOVE --.1 MAXIMUM 4 IN. �,!/ NGINEERS_ LOCATION A I SEISMIC CABLE BRACE FOR 3345LENEXAUS6 SUITE 300 LONGITUDINAL SEISMIC SOLID BRACE L25000KID[ 94 EXHAUST HOODS ATTACHED TO WALL ALL-DIRECTIONAL SEISMIC CABLE SEISMIC RESTRANT wxo9www.he eng.c 7425001 www.hei-en9.cem "TS BRACE FOR SUSPENDED EQUIPMENT 9 OF WATER HEATER $ FOR CLEVIS SUPPORTED PIPE/CONDUIT 1592095935 10 NTSNTS NTS SEISMIC JOIST ATTACHMENT SEISMIC JOIST HARDWARE ATTACHMENT SEISMIC JOIST ''2 '' HARDWARE TYP SEISMIC CABLE _•I..,, ATTACHMENT _.,,_, CIF BRACE TYP Tib HARDWARE '0 SEISMIC JOIST �Ir _„�_, co "/-SEISMIC ATTACHMENT "+u III III w III III it CIF �n;u, HARDWARE TYP _!iv_, IF SEISMIC CABLE CIF \ ♦` ' "`� ♦� III III 12 ta0 .. BRACE TYP p;`- ALLTHREAD SEISMIC SOLID ♦, ♦` III i _\�j� SEISMIC ALLTHREAD ROD TYP BRACE TYP ROD TYP Z ALLTHREAD ROD BRACE PIPE CLAMP PIPE CLAMP ALLTHREAD ROD W OR U-BOLT OR U-BOLT H PIPE CLAMP r SEISMIC-CABLE OR U-BOLT O o BRACE HOOK _IL 45'±15' _IL Z L.L TYP J L P.)) ti)) — — — `'',.: STEEL BRACE Q O STEEL BRACE ` _ 1� i� �� �� ,,, �n AIRCRAFT CABLE J LZ_J I 45'±15' -' 1- °;- - BY SEISMIC L_ J L Or,. emm) ii))RESTRAINT 45'±15' '�� J 45'±15' h - ATTACSEISMIC HMENTLE BRACE WTH ONLY SHOWN IN HOOK MANUFACTURER 'VOr... AIRCRAFT CABLE m .: �:� BY SEISMIC TRANSVERSE DIRECTION FOR CLARITY. J `�- o`� 1 RESTRAINT ADDITIONAL BRACING IS REQUIRED AS O +� 1 MANUFACTURER SEISMIC STEEL BRACE ONLY SHOWN IN SHOWN IN PLAN VIEW BELOW. ) } TRAPEZE SUPPORT a 0 II* TRANSVERSE DIRECTION FOR CLARITY. ) TRAPEZE SUPPORT W V ADDITIONAL BRACING IS REQUIRED AS .. .. } } �'� ' CC SHOWN IN PLAN VIEW BELOW.111. �- L7 �. a i :4‘ 0 M PI41j) �� l N _ 2 a' a' 4�pHll :gpiglll,'•� ���IIIUipq O O W �4� �V, ``■■� J PIPE CLAMP MAY BE ROTATED TO GAIN ACCESS :1 Q Q cf / TO STRUCTURE ABOVE O O MAXIMUM 4"-i } } } p 2 zpd o Q LONGITUDINAL SEISMIC CABLE BRACE ALL-DIRECTIONAL SEISMIC SOLID BRACE ALL-DIRECTIONAL SEISMIC CABLE BRACE TRANSVERSE SEISMIC SOLID } BRACE CO FOR CLEVIS SUPPORTED PIPE/CONDUIT 6 FOR TRAPEZE SUPPORTED PIPE/CONDUIT © FOR TRAPEZE SUPPORTED PIPE/CONDUIT 4 FOR TRAPEZE SUPPORTED PIPE/CONDUIT REVISONSNTS NTS NTS SEISMIC JOIST _ _ THE MECHANICAL, ELECTRICAL, AND - 'EI-u, ATTACHMENT "="; SEISMIC CABLE r ISI HARDWARE TYP BRACE TYP �il REFRIGERATION SYSTEMS FOR THIS PROJECT CATE tION III III , ,t`` SHALL BE SEISMICALLY RESTRAINED. THIS 12.2316 ALLTHREAD SEISMIC JOIST SHEET DEPICTS SCHEMATIC INSTALLATION %RANO. ROD TYP SEISMIC JOIST ATTACHMENT DETAILS AND IS FOR INFORMATIONAL """ ,a ix.,ATTACHMENT , i•., HARDWARE TYP " PIPE CLAMP nfHARDWARE CIF SEISMIC CABLE njr CIUD FIE SEISMIC -�J ♦. III amu` c - BRACE TYP OR U-BOLT PURPOSES ONLY. SPECIFIC INSTALLATION = III t SOLID BRACE . '� INFORMATION REGARDING SEISMIC RESTRAINT SIC RILE J L 45t15' /�\ J SHALL BE OBTAINED FROM THE SEISMIC t,� / � / BY SEISMIC ALLTHREAD ALLTHREAD ROD ALLTHREAD ROD RESTRAINT MANUFACTURER. REFER TO THE SEISMIC • �► i� �► ___ ,o RESTRAINT RESTRAINT MANUFACTURER SPECIFICATIONS FOR FURTHER INFORMATION. SEISMIC CABLE } ill BRACE HOOK TYP J L STEEL BRACE _III_ J L TRAPEZE SUPPORT 45'±15' `. .: AIRCRAFT CABLE 45x15' V p� �,- • BY SEISMIC �screiniair � RESTRAINT BCIF A ` /�� MANUFACTURER 11J( ll..[�.L/�1 -ISI ♦ p �F M .. PIPE HANGER1\dm PIPE HANGERS a �: SEISMIC CABLE BRACE HOOKTYP acc,.,,,G,,, p,, -MCRA.INC.w.wGHTS RESERVED �_ SHIT LI TRANSVERSE SEISMIC CABLE BRACE TRANSVERSE SEISMIC SOLID BRACE TRANSVERSE SEISMIC CABLE BRACE SR 1 W © FOR TRAPEZE SUPPORTED PIPE/CONDUIT © FOR CLEVIS SUPPORTED PIPE/CONDUIT O FOR CLEVIS SUPPORTED PIPE/CONDUIT WLI 0 Z NTS NTS NTS Q W N