Loading...
Report (120) Table of Contents SIEMENS 1 EQUIPMENT LIST / BILL OF MATERIALS 2 COMPONENT SPECIFICATIONS - FIRE ALARM SYSTEM 3 4 5 1 CO I- EQUIPMENT LIST/ BILL OF MATERIALS BILL OF MATERIALS SIEMENS Washington Square Mall Elevator Upgrade Fire Alarm System Interface Item Part# Qty Mfg Description 1 FP-11 1 Siemens Intelligent Photoelectric Smoke Detector 2 FPT-11 5 Siemens Intelligent Thermal Detector 3 DB-11 6 Siemens Standard Detector Base 4 TRI-R 4 Siemens Addressable Single Input Module with Programmable Relay (MXL) 5 MR-201/C 2 Siemens Single DPDT (Double Pole Double Throw) Slave Relay mounted in Metal Enclosure. Contacts rated for 10 Amps. @ 115 VAC PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1 5/19/2015 N I CO I-- COMPONENT SPECIFICATIONS FIRE ALARM SYSTEM Installation and Operation Manual [IOM] -Madel Part p ���� = „o'I Number Number Descriptibn '111 M-1 315-090725 Conventional Zone Module ILI-1 1 1H 11A 11AH 315-092724 Intelligent Ion Detectors ILP-1 /IPLT-1 315-092594 Intelligent Photo Detectors ILT-1 315-093336 Intelligent Heat Detectors ILI-1 B 11 BH 315-093234 Intelligent Ion High Velocity Detectors ILP-2 315-095028 FirePrintTMApplication-Specific Detection MSI-10B 120B 315-093329 Intelligent Manual Station MS-MI 315-092169 Intelligent Metal Manual Station TRI-B6 I B6D I B6R 315-093315 Intelligent Monitor Module[single 1 dual with array] TRI-B6M 315-094547 Intelligent Mini-Monitoring Module ICP-B6 315-092471 Intelligent Control Output[B6 chip] UM-1 315-092135 Line-Isolator Module FP-11 315-095921 Intelligent FirePrintTM Detector TRI-SIDIR 315-096242 Intelligent Monitor Module Note: For further details, refer to MXL IOM manual: 315-092036. Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 (511-FS) L6T 5E4/Canada November 2010 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Supersedes sheet dated 3/10 URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 Specifications — (continued) RED —and to continue flashing RED, until the detector locks, as well as an installation tool, preventing system is reset manually at the FACP. At that same unauthorized removal of the detector head. Model time, any user-defined system alarm functions DB-11 has integral, decorative plugs to cover the outer programmed into the system are activated. Each mounting screw holes. Model FP-11 detector can operate one (1) remote Model FP-11 is electrically compatible with existing alarm indicator;one (1)auxiliary relay, or one(1) MXL-detector accessories, including relays, remote audible base. lamps, duct housings and audible bases. With duct Detector sensitivity, calibration and identification housings, a base adapter and new detector housing are dynamically supervised by the FACP. Detector cover are required (order AD-11 UK upgrade kit). To use sensitivity and pre-alarm levels are a function of the existing Model DB-3S base or audible base, Model FP-11 application chosen at the FACP, and are controlled requires a base adapter(Model DB-ADPT). by the panel. If an alternate, non-FirePrint mode is All Model FP-11 detectors are approved for operation selected, then the sensitivity can be changed from within the 4UL-specified temperature range of 32°F the FACP. (0°C)to 100°F (38°C). The Program I Test unit (Model DPU) or FPI-32 upgrade kit is used to program and verify the Application Data detector's address.The technician selects the Installation of the Model FP-11 series of fire detectors accessory's program mode to enter the desired requires a (2) two-wire circuit of 18 AWG (minimum) address. In turn, Model DPU or FPI-32 automatically thermoplastic fixture wire enclosed in conduit, or 18 sets I verifies the address, and tests the detector. AWG (American Wire Gauge) limited energy, shielded Model DPU also allows the user to change the cable without conduit, if permitted by local codes. Field device ID from that of a Model FP-11 detector to an wiring should conform to local and national electric older detector ID (such as: ILP-1, ILPT-1, ILP-2, ID- codes and the control panel wiring specifications. 60P or ID-60PT) to allow for easy replacement of older detectors without the need of reprogramming "T-tapping"is permitted only for Style 4 (Class B)wiring. the FACP. Model FP-11 fire detectors can be applied within the The FPI-32 upgrade kit operates on AC power or maximum 30-foot center spacing (900 sq. ft. areas), as rechargeable batteries, providing flexibility and referenced in NFPA 72. This applications guideline is convenience in programming and testing based upon ideal conditions— specifically— smooth equipment from almost any location. When in test ceiling surfaces, minimal air movement, and no physical mode, Model DPU or FPI-32 upgrade kit will perform obstructions between potential fire sources and the a series of diagnostic tests without altering the detector. Do not mount detectors in close proximity to address or other stored data, allowing technicians ventilation or heating and air-conditioning outlets. to determine if the detector is operating properly. Exposed joints or beamed ceilings may also affect safe Model FP-11 may be installed on the same initiating spacing limitations for detectors. Should questions arise circuit with IL or ID series detectors (Photoelectric, regarding detector placement, observe National Fire thermal, or ionization), MSI-series manual stations, Protection Association (NFPA) 72 guidelines. TRI-series interfaces, ICP output control devices, or CZM series of addressable, conventional-zone Dimensions modules. Diameter Base All Model FP-11 detectors can be cleaned in the ' 6" field —when required — by simply removing the ! ... - ,.._ detector cover and unsnapping the photo chamber. There is also the option of cleaning the interior of Overall the detector with a clean, soft cloth or brush, or Height replacing the labyrinth and bug screen included in 2.3" ""` the detector maintenance kit, Model DMK-1 1. j Model FP-11 uses the low-profile, surface-mounting VR,` 1 fir base, Model DB-11. This base mounts on a 4-inch octagon, square, or a single-gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self-wiping contacts for increased reliability. The base can be used with the optional Model LK-11 detector locking kit, which contains 50 SIEMENS Industry, Inc. Building Technologies Division Specifications —(continued) The FPT-11 is a 135°F (57.2°C)rate-compensated Each FPT-11 thermal detector is capable of operating detector. The microprocessor for the FPT-11 detector one"X"or"I"Series remote alarm indicator or auxiliary uses an integral EEPROM to store the detector's relay or audible base. The FPT-11 detectors use a address. Communications within the detector, as well surface mounting base, Model DB-11,which mounts as between the FPT-11 and the control panel (or with on a 4-inch octagonal, square or single gang electrical the FPI-32 field programmer I tester) are supervised box. Relay base Model DB-X11 RS mounts to a 4-inch and safeguarded against disruption by reliable square deep electrical box.Audible base Model ADBX- microprocessor-based error-checking routines. 11 also mounts to a 4-inch square deep electrical box. Additionally, the microprocessor supervises all EEPROM The DB-11, and the DB-X11 RS and ADBX-11 use screw- memory locations, and provides a high degree of clamp terminals for all electrical connections and self- EEPROM failure fault tolerance. wiping contacts for reliability.The bases also contain a The FPT-11 is listed as a self-testing device. The visible provision for an optional concealed locking mechanism Light-Emitting Diode (LED)from the FPT-11 flashes to prevent unauthorized removal of the detector head, green every four seconds to indicate it is Model LK-11. communicating with the control panel and to notify it has passed its internal self-test. Should the detector Application Data sense a fault or failure within its systems, the LED will The MXL uses ALD loop circuits with each circuit flash amber, and the detector will transmit that capable of supporting up to (60) FPT-11 intelligent information to the control panel. A quick, visual detectors. inspection is sufficient to indicate the condition of the The detector, or group of detectors, require a two-wire detector at any time. If more detailed information is required, a printed report can be provided from the circuit of minimum 18 AWG thermoplastic fixture wire MXL panel indicating the status and settings assigned enclosed in conduit, or minimum 18 AWG limited to each individual detector. energy, shielded cable without conduit if permitted by local building codes.Wiring should conform to local and When the FPT-11 moves to the'Alarm'mode, the FPT- National Electrical Codes, and to the control panel's • 11 will flash amber and transmit that data to the wiring specifications.T-tapping is permitted only for control panel. When the MXL(V)confirms the current Style 4(Class B)wiring. condition of the FPT 11, the panel will instruct the FPT- Locate the FPT-11 on the ceiling, at least 4 inches from 11 detector to flash'red'until the system is reset at the the side walls. For an ideal, smooth ceiling condition, control panel. At that same time, any user-defined, system alarm functions programmed into the MXL place the detectors at a maximum center spacing of 50 System are activated. Each FPT 11 detector can feet(2,500 square feet), 25 feet from side walls or room operate (1) remote alarm indicator, (1) auxiliary relay, partitions. For FM approved installations,the FPT 11 has or(1) audible base, and only(1)accessory per a RTI rating of'QUICK.' Use a maximum center spacing of detector. 20 feet(400 square feet), 10 feet from side walls or room partitions. A DPU or FPI 32 programmer 1 tester is used to Actual job conditions and sound engineering judgment program and verify the address for the FPT-11. The user selects the'Program'mode to enter the desired must determine detector spacing. Consider address. The programmer 1 tester then automatically environmental factors including ambient temperature sets and verifies the address as well as test the fluctuation, and the nature of the fire hazard. Room or detector. The programmer I tester contains area configuration and ceiling type(sloped or flat, rechargeable batteries, in order for the address of the smooth or beamed)also dictates placement. FPT-11 to be programmed by the user from the most Should questions arise regarding detector placement, convenient location. The user can also separately test follow the drawings provided and I or approved by the FPT-11 detector for functionality. When the user Siemens Building Technologies—Fire Safety Division or selects the'Test'Mode, a series of tests are by its authorized distributors. automatically conducted, and the user is informed whether the FPT-11 detector has passed or failed. The FPT-11 detector is compatible on the same MXL- initiating circuit with other IL Series, FP Series or ID-60 Series addressable ionization, photoelectric, or thermal detectors, MSI addressable manual stations, • TRI Series addressable interfaces, or CZM Series addressable conventional zone modules. Building Technologies Fire Safety&Security Products Technical Data Details for Ordering Current Requirements: Normal 750 pa Alarm 750 pa Model No. Part No. Description ---> fPT-1i 500-095918 �Addressable Thermal Fire Detector Operating Temperatures: +32°F(0°C)to DB-11 500-094151 Detector Mounting Base for Series 11 100° F (38°C) 08-11E 500-094151E Small 4.5 inch Diameter Detector Base Humidity: 0-93% Relative Humidity D8-X11RS 500-096125 Relay Base for Series 11 Intelligent Non-condensing Detectors ADBX-11 500-096181 Audible Base for Series 11 Intelligent Detector Mounting Diagram RLI-1 500-390673 Remote(red)alarm indicator-octagon box mount RLI-2 500-695350 Remote(red)alarm indicator-single 6"(15.2 cms.) gang box mount I DIAMETER BASE LK-11 500-695350 Base Locking Kit for Series 11 _ DB-AOPT 500-094187 Base Adapter to DB-3S Base �~_~� In Canada Order: T7, Model No. Part No. Description 2.3" ^--�r---1� FPT-11C 500-095918C Addressable Thermal Fire Detector MCI J.8cros.) �' J r OB-11C 500 095687 Detector Mounting Base for Series 11(ULC) 4 -- '1(-:-.,\'�'we/. � ri :7 DB-X11RSC 500 096125C Relay Base for Series 11 Intelligent o V w eJ, Detectors(ULC) ADBX-11C 500.096181C Audible Base for Series 11 Intelligent Detector(ULC) Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Building Technologies Florham Park,NJ 07932 Brampton,Ontario Fire Safety&Security Products Tel:(973)593-2600 SFS L6T 5E4/Canada July 2009 FAX:(908)547-6877Printed in U.S.A. Tel:(905)799-9937 Supersedes she(Reet i datedd 12/03 URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 is in trouble condition, and red to indicate a change of Mounting Data state. The TRI-D flashes twice, once for each address, Addressable interface Model TRI-S,TRI-D,TRI-R theR red L.E.D. indicates a change of state in mounts directly into a 4 inch square 2'/4 deep box rel the relay. or a double gang box (user supplied). A 5 inch square The device's microcomputer chip has the capacity of off-white faceplate is included with each TRI. storing, in memory, identification information as well as important operating status information. MOUNTING SLOTS FOR 4 INCH Siemens Building Technologies, Fire Safety Division SMCIIB x innovative technology allows all TRI Series intelligent . interface modules to be programmed by using the - -�` 's"-ti..- ., model DPU or FPI 32 Programmer/Tester. The Pro- ', o C', I grammer/Tester is a compact, portable, menu driven 1..-> accessory that makes programming and testing an ��� —TRI-SI_O1-R interface device faster, easier and more dependable ? rim `, Mo013LE than previous methods. 3 ` 4 F OUl TING The DPU or FPI-32 eliminates the need for mechanical 1 e addressing mechanisms, such as program jumpers, 7._ -' HOLES FOR E DIP switches or rotary dials, because the Programmer/ v `Ttif L"T Tester electronically sets the TRI interface's address into the interface's microcomputer chip nonvolatile memory. Vibration, corrosion and other conditions thatb. , r deteriorate mechanical addressing mechanisms are no , longer a cause for concern. MOUNTING S;ars The TRI Series is fitted with screw terminals for F-o i oouu i~G NG connection to an addressable circuit. SINTCHROX The TRI Series is fully compatible on the same MXL Figure A circuit with all intelligent FF IL and ID-60 Series Mounting the TRI-S/-R/-D • detectors, MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICR Electrical Ratings All TRI Series intelligent interface modules are Current Draw (Active or Standby): 1.5mA UL listed. TRI-R Environmental operating conditions for all TRI Series Relay R, 125s Resi modules are 32°F (°C) to 120°F (49°C) with a relative Resistive: 4A, 15 VAC humidity of not greater than 93% non-condensating. 4A,300VDC Inductive: 3.5A, 120 VAC (0.6P.F.) Ordering Information 3.0A, 30 VDC (0.6P.F.) 2.0A, 120 VAC (0.4P.E) Shipping Wt. 2.0A, 120 VAC (0.35P.F.) Model Description Lb. Kg. 2.OA, 30 VDC (0.35P.F.) TRI-S Single Input 7 oz. .2 --> TRI-R Single Input w/Relay 7 oz. .2 TRI-D Dual Input 7 oz. .2 Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 5/06 Brampton, Ontario Siemens BuildingTechnologiesTel: (973) 593-2600 5M Canada L6T 5E4 FAX: (973) 593-6670 SFS-IG Tel: (905) 799-9937 May2006 Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905)799-9858 Supersedes sheet dated 7/03