Loading...
Plans (14) BUP2O1 6 - 00345 .RECEIVED GENERAL NOTES / PROVIDE PLUMBING FOR FUTURE TENANT INSTALLED YK ' DEC 1 3 2016 A�� SINK. VERIFY LOCATION CITYOFTIGAR® ���` ' 1' I. THESE PLANS FOR SPECULATIVE TENANT IMPROVEMENT 1. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALL W/TENANT, �r ONLY. DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE IITI,nIN fiIViSin c..---,..-, DRAWINGS AND SPECIFICATIONS AS WELL AS THE I ii 11 1 II 1 1 11 11 11 11 - - E. L OUNG 2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, PHYSICAL CONDITIONS OF THE SITE. NOTIFY THE — 1 ii u u PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK 0 N O •1111 r o ' I I ' I I O , I • F. ti . • TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF E E rr iii E` IF �I E ►O' t, ' THE PROJECT IN COMPLIANCE WITH THE APPLICABLE a DIMENSIONS ARE FROM FACE OF FINISH MATERIAL. • _ GOVERNING BUILDING CODES AND REGULATIONS. WHERE N 1� JO! E EO L�=�-1 MATERIALS, ASSEMBLIES,EQUIPMENT,FIXTURES, AND 9. PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY / I- Jr T — OF SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT IS THE NEW WORK TO EXISTING CONDITION OR NEW CONDITION, I. -94) (J1i RESPONSIBILITY OF THE GENERAL CONTRACTOR TO WHICHEVER IS APPROPRIATE. 1 DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC EO OE I MATERIALS AND DETERMINE CONSTRUCTION DETAILING, 10.EACH SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC iE ABORATORY L _ + + - 1 ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK OFFICE �0;(O OLF. = 100 REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS WITH ALL TRADES TO AVOID CONFLICTS. E AND METHODS OF INSTALLATION. IT IS THE CONTRACTOR'S 1 D5 OLP. = Imm 169 SF./ Imm RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS IN II. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF ♦ 146 SA / Imm = 2 OCCUR COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. OSSC SEC. 10043 AND SHALL SE EITHER A LEVER OR = 2 OCCUP. FF: VCT 0 PANIC TYPE REQUIRING ONLY A SINGLE MOTION TO OPEN. FF.: SEALED CONCRETE 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN E , r- p ,� MEANS,METHODS, TECHNIQUES AND SEQUENCES OF DOOR OF B, F,M OR S OCCUPANCIES ONLY,WITH THE 0 E U pp (`I CONSTRUCTION INCLUDING JOB SITE SAFETY. THE UNLOCKED DOOR FREE TO SWING WITHOUT OPERATION OF / Er N ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, ANY LATCHING DEVICE AND A SIGN READING "THIS DOOR E Qi': l� ' METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION MUST REMAIN UNLOCKED DURING BUSINESS HOURS" O O\ INCLUDING JOB SITE SAFETY. PLACED ON OR ADJACENT TO THE DOOR. - - 1 1 - 0 3, 9= _ N 4. THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE 12_PROVIDE TEMPERED GLAZING AT WINDOWS t RELIGHTS ` $ ABORATORY AFP. �" { M ALL THE LABOR MATERIALS, TRANSPORTATION, EQUIPMENT, PER SECTION 2406 STATE OF OREGON STRUCTURAL / E i OHO AND SERVICES NECESSARY FOR AND REASONABLY SPECIALTY CODE_ TOP OF FLIGHT FRAMES TO MATCH / UOS O1F_ • 100 �--' INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION TOP OF DOOR FRAMES. E 366 SF. / 100 E - - - T J U N WORK IN CONNECTION WITH THE DOCUMENTS. ♦ ` 4 OCCUP_ 1 .� I O Lz. 13.VERIFY KEYING REQUIREMENTS WITH LANDLORD, E FF: VCT E ES' I: 5. APPLICABLE CODES ON MATERIALS AND WORKMANSHIP OFFICE 0 L - _ - J L J L J SHALL CONFORM TO THE UNIFORM BUILDING CODE AND 14.PROVIDE 31/2". UNPAGED BATT INSULATION AT ALL NEW - b APPLICABLE STATE AND FEDERAL SAFETY ORDERS. ALL WALLS. 104 O.L.F. = Imm rr�-I= ct REFERENCES TO CODES,SPECIFICATIONS, AND STANDARDS 138 SF. / 100 I OP 1- SHALL MEAN AND ARE INTENDED TO BE THE LATEST 15.PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE • 2 OCCUP. 1-A33ORATORY '-' EDITION, AMENDMENT AND/OR REVISION OF SUCH MARSHALL AT WALK-THROUGH. FF.: SEALED , N L J VD ' ".11 REFERENCE STANDARD IN EFFECT. CONCRETE \ 109 OLF. = 100 c.►] 16.PROVIDE HVAC W/20 CFM OUTSIDE AIR PER OCCUPANT AT / OFFICE \ 1,124 SF. / 100 i U 1 a 6. EACH SUB-CONTRACTOR(OR THE GENERAL CONTRACTOR OFFICE AREAS. Q IOZ I OLP. = 100 i ` VERIFY POWER REQUIREMENTS = 12 OCCUR PROVIDE PLUMBING FOR 1- WHEN HE IS PERFORMING SPECIFIC PORTIONS OF THE E 250 SF./ 100 === d FOR TENANT INSTALLED 14000. FF.: VCT FUTURE TENANT INSTALLED ! �i WORK) IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE 11.MECHANICAL,ELECTRICAL AND PLUMBING SY SEPARATE E • 3OCCUP_ - MECHANICAL PEMIT BY OTHERS.FIELD AND SHALL,PRIOR TO PEORIMANCE O' WORK, PEMITS, SINK VERIFY LOCATION ,�NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT O= // CE FFN VERIFY LOCATION W/TENANT- W/TENANT. ROANY WORK CALLED OUT ON THE DRAWINGS IN HIS TRADE I8.MAINTAIN 100o FIRE SPRINKLERS PER FMA. 4 LATEST THAT CANNOT SE FULLY GUARANTEED OR THAT DOES NOT EDITION OF NFPA PAMPHLET M3, PROVIDE DRAIN FOR TENANT �1 0 C. MEET CUENT LOCAL BUILDING CODES. 9.FIRE SPRINKLERS TO BE LOCATED IN THE CENTER 2 -0" X / I INSTALLED SAFETY $MOWER. o >C N2 -0" CEILING ?ICES OR IN THE CENTER OF EITHER HALF O: / VERIFY LOCATION W/TENANT _ I t})�0/� p -.A 2-0 X 4' 0 CEILING TILE. rTMP. COFFI Ek OIn 103 OLF. • 1001 -I0" 6'-0" 1 -I0" 6'-0" E —NEW 3'-0"XT-0" GLASS o 138 5F. / 100 , / t •• - I dr STOREFRONT / FF: SEALED DOOR ASSEMBLY iii 0 JI ♦/ E E, CONCRETE p F 6'-O��X,4,1_O�� 6'-0"X4'-0" "}' r WINDOW WINDOW • I - W _ SEALED VCT _ O / , E CONCRETE/ ( In COMMON PATH OF TRAVEL = 93'-6" J P \ E LI o E OFFICE \ 102 OLP. • 100 SEALED /VCT _ / 132 SF. / 100 CONCRETE = 2OCCUP. FCONCRETE , mo • m" - E CODE SUMMARY a o `� o a w . E E o� OFFICE • GENERAL BUILDING DESCRIPTION: GENERAL OFFICE/WAREHOUSE C/] GE •0 9) 110 OLP. •• Imo z 'z • 185 S.F. / 100 NUMBER OF STORIES: 1 [� 1--ICn to 0 = 2 OCCUR FIRE SPRINKLERS: 100% COVERAGE z i--I FF: VCT EO OCCUUPANCY:BUILDING EB33,000 SF.3 - CITY OF TIGAREI n w E" CONSTRUCTION TYPE: III-15 REVIEWED FOR CODE COMPLIANCE > hq 4 0 TENANT SPACE SIZE: 1,026 SP.± O OPEN OFFICE E OTC's (. 1 I— r 1Imm 100 o 6 . 100 Permit#k . /QGfP��! —(f �_ y� H • II B 0 / 100 25165F. / 100 ♦ GUP_ • 26 OCCUR. O / E FF. SEALED FF: SEALED E E Address: `ce y s ser) to ;` 7. CONCRETE ♦ CONCRETE 4 . . LEGEND / E / O EOE EO EOE Suite#! (('j ,( w x to ./ / - By: ea Daus (A/1/4, LFF w v a EXISTING WALL TO REMAINE �� gl 0 i '♦ 0 E EXISTING WALL TO BE REMOVel 4c J `!! 7 U DJ COPY o SE-VER OFFICE COPY E ci III E0- 112 NEW WALL - 3%" METAL STUDS g w FF: SEALED FF: SEALED 24" OC. 54" GYP. BD. EACH SIDE U CONCRETE CONCRETE 0 E ---]E $ in 0E O O EXISTING DOOR TO REMAIN r OFFICE 12/01/16 118 NEW OR RELOCATED DOOR FF: TO REMAINO 3'-0"x1'-0" U.oN. O OE AS-IS k O Oe KO.______ Oe ;FE/E 1 \4/ E F in_ _ EO / DOOR TO SE REMOVED OR /CBR/ JI _ / II RELOCATED O EO I H £ OUNS 0 EXISTING DUPLEX ELECTRICAL 19'-5"t D OUTLET TO REMAIN f ELECT, FF: TO REMAIN 113 E EXISTNG DUPLEX ELECTRICAL OFFICE OFFICE 'S-IS FF: SEALED OUTLET TO BE REMOVED 11V O.L.F. • 100 116 OLP_ • 100 MENS CONCRETE 296 SF. / 100 250 S.F./ 100 114 NEW DUPLEX ELECTRICAL me • 3 OCCUP. 3 OCCUP. E0 a FR TO REMAIN 1 0 OUTLET. BOTTOM OF COVER FF SEALED FP.: SEALED AS-IS PLATE TO BE AT 15" APP. H\ CONCRETE CONCRETE E° I \ 'Li : N _ NEW OUTLET (203V) I BOTTOM OF COVER PLATE TO BE AT I5" AFF. J NEW 4-PLEX ELECTRICAL KN-----.__ OUTLET E E E E E E E E �� 1 BOO 4 4 40 iCp O € O E EXISTING MUDRING AND PULL I I I I I I v WIRE NEW MUDRING AND PULL WIRE FE e GROUND FLOOR PLANANCOvETENANT PI PROVIDEDC.TO E ATPMONF V AND DATA WIRING. BOTTOM OF ,, 1/4 11-0"0 EXISTING POWER 4 DATA �E PROVIDED VIA HARDWIRED CONNECTION 4 WHIP. ,%, I 1 1 \ POWER 4 DATA PROVIDED VIA / 20 GA. 3t'z" METAL STUD BRACING TO 0 A 1 HARDWIRED CONNECTION 4 WHIP- i ROOF STRUCTURE AT 6'-0" O.C. //ii r9�! ACTUAL LOCATIONS TO BE �' ALTERNATING DIRECTIONS. FASTEN PROVIDED BY SYSTEMS �i / BRACE TO TOP OF STUD W/(2) "8 0 �►/ i FURNITURE INSTALLER SHEET METAL SCREWS AT EACH END. AREA OF j d�A ` tea �� ai .�' BRACING TO BE PROVIDED WHERE WORK / ',/ . %/ �• ' INTERSECTISTANCE NG WALLS OR HORIZONTAETWEEN L i� �• �• BRACING BETWEEN WALLS EXCEEDS �/ /�`/ /��7 . ' SUSPENDED CEILING Ir r r�`� '' ` �• ATTACH BRACE DIRECTLY \ .:P TO STUD. \ \ \ A.1 %" GYP, BD. EA. SIDE I o o - -, L. II WIMP 1111 a r 31/2" SOUND BATTS —w-I , F M—, \ \ TEMPERED GLAZING - ATIGAVITY j :Il // �\ STANDARD MATCH �� e 4 METALOSTUDS (25 GA) 'al 1 �� \ \ oa FOR SIZE OF , GLAZING BOTTOM TRACK TO FINISH \\\\\\� • _ " mor �L-.. I��`�, el / r / r FLOOR WITH POWDER .k DRIVEN ANCHORS e 2'-0" O.C. .: CONCRETE SLAB. V OBA #16104 • I a - /_ / o L \ \ 1 TYP. WALL DETAIT J \ 31-0" it 3,_0" X �� -9 11/2". 11-0" illak KEY PLAN TYPE - 4 TYPE - B A. 1 illir NOT TO SCALE OF 2 . A a in t G ir Pa•• r .L 14• . X/ / / OF C • I X ■ X ON I ■ / X N E.S. M OO X • Pr 0 w XB.B. X ■ a X ---------------- X ..--------------- X . 0 -1 m rco 00X 10. ____._...------"--- . ________--------- . F— — —,..---1X XNk cm 14 cn tinO • IP 1 TYP a F-; ._.J / _ 5.5. n I ■ „ail I EXISTING 2X4 T-BAR / / CEILING 69'-0" A.F.F. / / Pr ' X / BB. BB. }■ EXISTING 2X4 T-BAR CEILING 611'-6" AFF. ././ X X � a a u, z p t6 rn _Th X . a pg 4 ° X / . • / 04 gel 2 r / Zv / Nv) We / Ir / / / • F LEGEND 'i / 3/Ill / U EXISTING SPRINKLER HEAD • X LOCATION • / ■ EXISTING HVAC RETURN / X X 5_5_ X \ / / / / / / r / 5.5 ■ J X EXISTING NVAG DIFFUSER IL . • . - igia— ESL FIXITURE TO REMAINSCENT 12/01/16 ■ J% • r / 71 EXISTING 2X4 FLUORESCENT I1 1 _ J FIXTURE TO BE REMOVED • NEW OR RELOCATED 2X4 FLUORESCENT FIXTURE r /■ / XL:±a/------ ■ 1,_-__ _J / :. EXISTING 2X4 18-CELL BB. PARABOLIC FLUORESCENT FIXTURE TO REMAIN ES. Sr EXISTING 24 HOUR NIGHT LIGHT Pr CIRCUIT CADD BATTERY 4E- -' • • BACK-UP) X . X :::" 24 HOUR NIGHT LIGHT CIRCUIT ■■ _ i - -- WITH BATTERY BACK-UP B TE B P R F ��� BB_ BB. I .._- �. — w" EXISTING SURFACE MOUNTED 1X4 • F :,.:.::,.:.,: .:.•:,.:. .••F FLUORESCENT FIXTURE :......:...:. Fp EXHAUST FAN EXISTING ILLUMINATED EXIT SIGN ES I WITH BATTERY BACK-UP TO a REFLECTED CEILING PLAN REMAIN ESC EXISTING ILLUMINATED EXIT SIGN ,, "I/4 = 1'-0" TO SE REMOVED • NOTE: HVAC DIFFUSERS 4 RETURNS AND FIRE SPRINKLERS SHOWN ONLY IN EXISTING LOCATIONS FOR CONTRACTORS CONVENIENCE. RETURNS AND FIRE SPRINKLERS TO SATISFY BUILDING, MECHANICAL AND FIRE CODE. 0a4 016104 A- 2 OF 2