Loading...
Plans (4) BUP2O1 6 - 00299 TKG RECEIVE OCT 192 )16C DU I JO ON 4, e„ • CITYOFTICA `s ` BUILDING DT/IS 4 SAINT 586 s, OR � ' OF0 0 TIGARD , OREGON 4 t AREA OF WORK cs1 T1.1 SUITE 215 '. r t TKG TENANT ,- ' SCOPE OF WORK FOR SUITE 215 CONSISTS OF DEMOLISHING EXISTING I'''//1frs 44 { I OFFICE PARTITIONS AND BUILDING NEW INTERIOR PARTITIONS FOR PRIVATE '- OFFICES, CONFERENCE AND BREAK ROOM. SUITE 215 IS AN EXISTING OFFICE, 7340 SW HUNZIKER RD, SUITE 215 III I ,`j / ' I GROUP B OCCUPANCY, AND WILL CONTINUE TO BE USED AS OFFICES. NO N N MODIFICATIONS TO MEANS OF EGRESS OR TOTAL OCCUPANT LOAD ARE V) TIGARD, OR 972234,11pi I� _ `' , I PROPOSED WITH THIS PERMIT APPLICATION. w 4I I ', , A`;, DEFERRED SUBMITTALS a N N 1 . • MECHANICAL* a •o • • ELECTRICAL* w = ROBINSON CONSTRUCTION CONTRACTOR • _ _ _ _ Ft FIRE ALARM N N I PLUMBING 1;1 IF 41 _�� *DESIGN-BUILD CONTRACTOR SHALL COMPLETE, AS NECESSARY, REQUIRED 21360 NW AMBERWOOD DR CONTACT: RYAN ROBINSON OI' A PORTIONS OF THE OREGON ENERGY COMPLIANCE FORMS HILLSBORO, OR 97124 —1 .• ���■ BUILDING CODE SUMMARY TELEPHONE: 503.645.8531 2014 OREGON STRUCTURAL SPECIALTY CODE FAX: 503.645.5357 I I CONSTRUCTION TYPE: V-A, NON-SPRINKLERED NOT IN I OCCUPANCY GROUP: B I SCOPE BUILDING AREA: I 1ST STORY: 7,857 S.F. 2ND STORY: 7,964 S.F. CIDA, INC. ARCHITECT TOTAL: 15,821 S.F. (NO CHANGES) PORTABLE FIRE EXTINGUISHERS (OSSC 906): PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN OCCUPANCIES AND LOCATIONS AS REQUIRED BY All 15895 SW 72ND AVE, SUITE 200 CONTACT: JENNIFER HAWKINS THE OREGON FIRE CODE AND THE FIRE MARSHALL Nowni PORTLAND, OR 97224 ® EGRESS PLAN ONLY -- 2ND FLOOR OCCUPANCY LOAD (OSSC 10041: TELEPHONE: 503.226. 1285 © 1/16"=1'-0" GROSS FLOOR AREA (SUITE 215): 1010 SF (TOTAL) / (100 SF/OCC) = 10.1 = 11 OCCUPANTS1.1 (SEE ALSO OCCUPANT LOAD TABLE ON THIS SHEET) ARCHITECTURE FAX: 503.226. 1670 MEANS OF EGRESS ILLUMINATION (OSSC 1006); ENGINEERING G I N E E R I N G ILLUMINATION LEVEL (OSSC 1006.2): P L A N N I N G MINIMUM 1 FOOT—CANDLE AT THE WALKING SURFACE LEVEL INTERIOR S ILLUMINATION EMERGENCY POWER (OSSC 1006.3): EMERGENCY POWER SHALL BE PROVIDED FOR A DURATION OF 90—MINUTES MINIMUM LANDSCAPE AREAS REQUIRED TO BE ILLUMINATED BY EMERGENCY POWER 15895 SW 72ND AVE SUITE 200 — CORRIDORS AND EXIT PASSAGEWAYS CO — INTERIOR EXIT DISCHARGE ELEMENTS PORTLAND. OREGON 97224 — EXTERIOR LANDINGS TEL : 503 . 226 . 1265 (� FAX : 5 0 3 . 2 2 6 . 1 6 7 0 W k — — EMERGENCY POWER FOR ILLUMINATION (OSSC 1006.3): www . c I o A I N c . c 0 M INITIAL ILLUMINATION: 1 FOOT—CANDLE AVERAGE W/ 0.1 FOOT—CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL • P END OF EMERGENCY LIGHTING PERIOD: 0.6 FOOT—CANDLE AVERAGE W/ 0.06 FOOT—CANDLE MINIMUM AT ANY POINT AT FLOOR LEVEL Z G V } MIT SIGNS (OSSC 10111; Wa U, SEE 9/T1.2 FOR LOCATIONS OF EXIT SIGNAGE a ILLUMINATION (OSSC 1011.3): CITY OF TIGARD J m 0 J EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED REVIEWED FOR CODE COMPLIANCE WApproved: [ICI LO w z e. 4 2 JIffilliI s — 1• �� , ...... Q 2I Cr W = = 5 z I. (TABLE 1016.2) N _ �— g BUILDING, B OCCUPANCY: 200'-0" ALLOWED TPertnit#: E; 9 XO i G— 00 actq (n o V o a I 1t Lu La 1-- 0O es I I I ' ' 40 e �JZ NU S:.J leu ni ZTfc/LRi W MAX DISTANCE = 125'-4" Address: W v r a a w o - Suite#: (a)'i 1` EGRESS (TABLE 1021.2) _ NOT IN I — - TOTAL OCCUPANTS: BY: PIA! Date: OV o Q ~ ~ i i i SCOPE • I DISTANCE TO DOOR = 55'-8" - // / J' IX N M I 19 OCCUPANTS, >75' MAX TRAVEL 1 EXIT REQUIRED C� ///2S/�&' a-J& 2 cV I 1 EXIT PROVIDED w N 1 70.10.16 REVIEW SET • • • ' `o ,--.--.--1.3-----7 — I— Q N 2 10.12.16 PERMIT SET , • - EGRESS WIDTH REQUIRED ABLE 1005.1 CITY OF Z (� ) TIGARD W 0 CC CFI /l/. % _ SUITE 215 PASSAGEWAY EGRESS WIDTH REQUIRED (19 x .2) = 3.8" Approved by Planning W SUITE 215 PASSAGEWAY EGRESS WIDTH PROVIDED 50" Date: lol lei Ilia o IX Ct STAIRWAYS EGRESS WIDTH REQUIRED (19 x .3) = 5.7" W O --k STAIRWAYS EGRESS WIDTH PROVIDED = 54" Initials: ,kE cc 0 Y \ O I a. — SW DARTMOUTH ST NORTH ACCESSIBILITY (OSSC CHAPTER 11 AND ANSI CHAPTER 5): I— I Z ct �PL UG DR. n H H SEE FLOOR PLANS FOR REQUIRED CLEARANCES AT DOORS, TOILET ROOMS (EXISTING) AND FIXTURES. Z s ADEN = Ii i ii ii I EGRESS PLAN ONLY -- 1ST FLOOR ALL SIGNAGE GRAPHICS, LOCATION AND MOUNTING TO COMPLY WITH OSSC CHAPTER 11 Z = /4/r� SW ;LMHURSf Sf. g, a . t 'L� t T - _. _._. . . .. 00 1/16"=1,-D" W V o SW HERMOSO W Y �' 0 , �' II o SW BEVEIAND I S '• NKLIN n� to II * < < F © © - o DEFERRED N H a a K �W v� , II I - OSSC 1004 OCCUPANT LOAD TABLE Fire Sprinkler 1CCI TREECE - - - €to 2 e ,o I Fire Alarm �_ M DEMO FLOOR PLAN LEGEND µ, SW 1AMPTON ST. H 6 •II F ,I L- Mechanical HUNZIKER RD 'r a n /� 1 ROOM Plumbing /11 NAME OCCUPANCY TYPE LOADING AREA LOAD Electrical -4 N- SW CRESIVEW �R © (E) FRAMED WALL TO DEMO # FACTOR Truss Engineering GS'' O ), 100 RECEPTION BUSINESS 100 331 4 Shop Drawings 2 I SW VARNS ST S .8TH • 1c Oqt r--1 E. " I 9f. se 1 1 I (E) FRAMED WALL TO REMAIN 101 CONFERENCE BUSINESS 100 151 2 Other _ �1 1 \�\ — --- --y 102 BREAK ROOM ASSEMBLY 15 105 7 N ^� "�" — — -_ DEMO FLOOR PLAN KEYNOTES ,03 OFFICE BUSINESS 100 158 2 G m A 1 I N 8 \ 104 OFFICE BUSINESS 100 104 2 N. N N " Kvy $ O DEMO (E) WALL 105 OFFICE BUSINESS 100 161 2 o *� r ti SW SANDBURG ST \c--) I ,^ TOTAL FOR OCCUPANT LOAD 1010 19 SW TECH CENTER DP,. S ,/ © DEMO (E) DOOR, RELITE, HARDWARE AND FRAME, SALVAGE FOR ao RELOCATION. COVER SHEET & DEMO -F • cr. I 0 DEMO (E) CASEWORK AND SINK. SALVAGE SINK FOR RELOCATION IF OFFICE COPY PLAN SW LANDMARK N. FEASIBLE. ZONING CODE INFORMATION CS1 i 2 NORTH NOR'" DEMO FLOOR PLAN DEMO FLOOR PLAN GENERAL NOTES TAX MAP St 251010800104 VICINITY MAP JOB NO. 160257.01 6 0 . NO SCALE 1/8" = 1'-0 1. SEE SHEET T1.2 FOR ADDITIONAL CEILING DEMOLITION. ZONE: C—P, PROFESSIONAL COMMERCIAL o ©2018 CBD, P.C./CIDA ALL RIGHTS MEM Cu Cu WALL TYPES ELEVATION KEYNOTES DOOR SCHEDULE �`�� 4k NON RATED PARTITION WALL - 3-1/2" 25 i58L IN JOH SON O O 9 A �,A���. • • • .�����. GAUGE METAL STUDS ® 1'-4" O,C. W/ ONE O PAINTED GYP. BD. PER SCHEDULE DOOR # © (E) 100-A DOOR HARDWARE OPENING WIDTH DOOR DOOR DOOR FRAME NOTES DOOR # "3 TYPE GROUP (E) -- x HEIGHT THICKNESS MATERIAL FINISH MATERIAL LAYER 5/8" GYPSUM BOARD EACH SIDE TO THE UNDERSIDE OF THE CEILING. PROVIDE 0 8-1, 4" BASE PER SCHEDULE (E00AI ISOUND ATTENUATION INSULATION. INSTALL PL-1, PLASTIC LAMINATE VERTICAL CASEWORK `9IWATER-RESISTANT GYP. BOARD AT WET WALL 101-A A 2 3'-0"x7'-0" 1 3/4" SC WD STAINED HMKD 1 101-A OF 0\k 14' 10 5/16" 1O'-0 1/4" 5 7/8"D'-10"g I LOCATIONS. SEE DETAIL 4/T1.2 O PL-2, PLASTIC LAMINATE ON COUNTERTOPS AND 4" BACKSPLASH WHERE SHOWN 103-A A 1 3'-0"x7'-0" 1 3/4" SC WD STAINED HMKD 1 103-A / i 111 © FLOOR PLAN LEGEND COUNTER MOUNT SINK 104-A A 1 3'-0"x7'-0" 1 3/4" Sc WD STAINED HMKD 1 104-A I 105-A A 1 3'-0"x7'-0" 1 / ,� 4.4O 3" VALANCE TO MATCH CABINETRY3/4" Sc WD STAINED HMKD 1 105-A ° FOFa ° - -- CORRIDOR ROOM NAME & NUMBER (E) EXISTING HARDWARE SCI"E;DULE ,, REUSE DEMOLISHED DOOR & LOCKSET WHEN FEASIBLE. ♦ ® ® O REFRIGERATOR- TENANT PROVIDED, CONTRACTOR INSTALLED NOTES: 101-A DOOR NUMBER FEC FIRE EXTINGUISHER CABINETes PROVIDE POWER/WATER AS NECESSARY re, A ADA HEIGHT DISHWASHER- TENANT PROVIDED, CONTRACTOR TYPE 1 E 2 OFFICE OFFICE FOF FACE OF FINISH b OFFICE103104 105 (E) EXTERIOR WALL O TYPE INSTALLED. PROVIDE POWER/WATER AS NECESSARY. ¢1 j a A (N) INTERIOR WALL O RELITE TYPE O FINISHED END PANEL 1 1/2 PAIR BUTTS 1 1/2 PAIR BUTTS 2 8- 1 , d A (E) FRAMED WALL 1 EA OFFICE LOCKSET 1 EA PASSAGE LATCH ABBREVIATIONS: �� © . :.1. 1 SET SILENCERS 1 SET SILENCERS (E) EXISTING gair 105-A SC WD SOLID CORE WOOD DOOR �i FOF ■*BREAK r FLOOR PLAN KEYNOTES 1 EA WALL STOP 1 EA WALL STOP I- 102 HMKD HOLLOW METAL KNOCK DOWN , k. ICI ° --_ O ALIGN NEW WALL WITH EXISTING. E E5 0 GENERAL NOTES: 101—A RECEPTION to tr. 100 O ALL NEW DOORS TO MATCH EXISTING, SPECIES, STAIN, FINISH, & HARDWARE. a N N -0 FLOOR PLAN GENERAL NOTES O ° 0 N THE OPENING FORCE SHALL NOT EXCEED 5 LBS FOR INTERIOR DOORS, 8.5 LBS FOR EXTERIOR DOORS, AND THE MINIMUM FORCE w o 0 CON : NCE 1. ALL CONDITIONS SHOWN OR IMPLIED ON THE DRAWINGS SHALL BE t o REQUIRED TO CLOSE AND LATCH THE DOOR FOR FIRE DOORS. OSSC 1109.9.9 n - 101 VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY m a ARCHITECT / ENGINEER OF ANY DISCREPANCIES PRIOR TO THE START 1 © ALL HARDWARE HALL COMPLY WITH THE REQUIREMENTS OF THE ADA. a 0 OF WORK- L�I -- - -- - - _© DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. o FOF . - . 2. ALL DIMENSIONS ARE TO CENTERLINE OF STUD AT NEW WALLS OR TO Sil. �� O01 , V FACE OF FINISH AT EXISTING WALLS UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY HARDWARE FUNCTION INDICATORS FOR ALL DOORS WITH TENANT PRIOR TO ORDER/INSTALL. • 10' 2 1/2" 11' 1 1/4" 3. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED AS '. REQUIRED BY APPLICABLE STANDARDS. a _ I ' ' 4. THE HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER U 17Q_© )1' "W" 4 2'- (. CONTROLS, DISPENSERS, ELECTRICAL AND COMMUNICATION SYSTEM O2 -p : 2RECEPTACLES ON WALLS AND OTHER OPERABLE EQUIPMENT SHALL BE0110,111.12 i _© WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN SECTION ��� \ / - - 1109.2, AND NOT LESS THAN 36" ABOVE THE FLOOR. ELECTRICAL '�� � \ / r x -- AND COMMUNICATIONS SYSTEM RECEPTACLES ON WALLS SHALL BE \ / Li '8� MOUNTED NO LESS THAN 15" ABOVE THE FLOOR (1109.3,2), 2'-0" 2'-4" 1 DOOR ''ER DP6R PER ~ ` - IJ = SCHEDULESCHEDULE Z ::: fl 5. PROVIDE OUTLETS ONE PER EACH OFFICE WALL. COORDINATE WITH 6'-0"OWNER. NO MORE THAN SIX 110 OUTLETS ON ANY ONE CIRCUIT. ALL 0::::o / \ li WALL PLATES WILL BE WHITE UNLESS OTHERWISE NOTED. ¢ o // \\ ¢ / F\ NORTH 6. CONTRACTOR TO COORDINATE LIGHTING WITH EXISTING HVAC. - T / \ T 1 FLOOR PLAN BREAK ROOM ELEVATION FIN. FLR. FIN. FLR. 61 7. RELOCATE (E) HVAC CONTROLS AS NECESSARY AND PROVIDE (N) HVAC ® RECITE RELITE ARCHITECTURE T1.1 1/8" = " CONTROLS AS REQUIRED. 1/4" = 1'-0" O FLUSH O © ENGINEERING U PLANNING INTERIORS 03 DOOR TYPES 4 RELITE TYPE LANDSCAPE T1.1 1/4"=1'-0" T1.1 1/4"=1'-0" 15895 SW 72ND AVE SUITE 200 PORTLAND. OREGON 97224 TEL : 5 0 3 . 2 2 6 . 1 2 8 5 FAX : 503 . 226 . 1870 WWW . C I D A I N C . C O M Q O O I I I 1 I II 1 - - „, FINISH FLOOR PLAN LEGEND ���u •..OFFICE ' OFFICE • ..17FFICE: N ROOM FINISH SCHEDULE • 1:1103 '•: " 1 . ..: . .- 1041 ;. ', ' '... .. 105 •; :.,A COIRpR(POR ROOM NAME & NUMBER W 011 ROOM # ROOM NAME FLOOR BASE N WALL E WALL S WALL W WALL CEILING HEIGHT NOTES F.-- 1 100 RECEPTION CPT-1 B-1 W-1-A W-1-B W-1-A, W-1-A C-1 (E) IX = M 4 -- VCT-1 - o- Rl_ "bK RF.t.I',:r. :. , CPT-1 - - - - - - - - - - - - N CPT-1 B 1 W 1 A W 1 A W 1 B W 1 B C 1 N CONFERENCE 101E) (V 102 BREAK ROOM VCT-1 B-1 W-1-A W-1-A W-1-A W-1-A C-1 (E) Z � 0 CC 0) -L. I 103 OFFICE CPT-1 B-1 W-1-A W-1-A W-1-A W-1-B C-1 (E) W ■ W-1-8 EW ® ■ 104 OFFICE CPT-1 B-1 W-1-A W-1-A W-1-A W-1-A C-1 O SeI-1-1 0 105 OFFICE CPT-1 B-1 W-1-A W-1-A W-1-A W-1-A C-1 (E) � Y FINISH FLOOR PLAN KEYNOTES _ N o 1DD ROOM O PAINT ALL SIDES OF COLUMN PT-C FN3EfS N�DEX ? X s. COIJFER NCE ` Q Q .1 101 • '." . • FLOOR MISSES RIMS F>#pSFI Z = CD NEW CARPET TILE, MOHAWK W-1 PAINTED GYPSUM BOARD C-1 (E) 2x2 ACOUSTICAL LAY-IN W I FINISH FLOOR PLAN GENERAL NOTES GROUP, DRIFTED GROUND, 358 W-1-A BENJAMIN MOORE CEILING E-" RIDGE WILLIAMSBURG COLOR • REPLACE DAMAGED TILES 1- PATCH AND REPAIR (E) FINISHES TO MATCH WHERE DAMAGE HAS COLLECTION, CW-710 • MATCH EXISTING V) ' I CI OCCURRED DUE TO DEMOLITION. VCT-1 VINYL COMPOSITION TILE, BRUTON WHITE _ MANNINGTON, ESSENTIALS, 152 FIELD CASEWORK O� 2. PAINT ALL NEW WALLS U.N.O. FIELD COLOR W-1-A. PUMICE, 12"X12" W-1-B BENJAMIN MOORE BASE WILLIAMSBURG COLOR PL-1 PLASTIC LAMINATE, NEVAMAR, f o 3. ADDITIONAL ELECTRICAL OUTLETS TO BE PROVIDED BY SUBCONTRACTOR COLLECTION, CW-580 BAILEY, WK0027T, FACE OF K) TO MEET ELECTRICAL CODE. B-1 ROPPE 4" RUBBER BASE, CASEWORK. N WETHERBURN S BLUE PL-2 PLASTIC LAMINATE, NEVAMAR, MATCHBOX, #174 SMOKE PT-C BENJAMIN MOORE 4. CONTRACTOR TO VERIFY WITH TENANT EXACT LOCATIONS AND COOL CHIC VA7002T, I HC-166, KENDALL -4-- . REQUIREMENTS OF ELECTRICAL AND PHONE/DATA OUTLETS. TENANT CHARCOAL COUNTERTOPS E. ' RESPONSIBLE FOR CONTRACT FOR LOW VOLTAGE DESIGN AND IG :"IOL INSTALLATION. 1 1 14 t. \ 5. VERIFY ALL FINISH SELECTIONS WITH TENANT AND OWNER. N 1 -I- r: 8 sP O R- NORTH FINISH FLOOR PLAN FLOOR PLANS & DETAILS * ® Ts1.1 ✓ h N o JOB NO. 160257.01 e ©2016 CW, P.G./OLA NL RIGHTS RESERVED 0 4 3 I j i 114%, DEMO RCP LEGEND �_e , NSONI I: 12 GA. SPLAY WIRES NO GREATER �-3THAN 45' FROM HORIZONTAL PLANE (E) 2X2 LAY IN ACOUSTICAL CEILING GRID � ® 4'- ATTACH TO BOTTOM SAINT H' ENS, OR 0" O.C., I I I tf� �I 41111 n UHL OF NEAREST JOIST ABOVE <i›,,,,_ 5865 # o -- ' '%'' (E) 2X4 LAY IN FLUORESCENT LIGHT FIXTURE TO BE III EXISTING SUSPENDED CEILING • • . .' C I ° 4=----1 RELOCATED r II' ll Tar 105 r-a (E) 2X2 LAY IN FLUORESCENT LIGHT FIXTURE TO BE i'1 12" LONG 1 5/8" UNISTRUT P1000 Will �j 4) REMOVED .�!, NSTALLEDI0 WITHELF WASHERISG SCREWS VI r r- I I E (E) ILLUMINATED EXIT SIGN .4, -- �e DEMO RCP GENERAL NOTES ►. CONT.RUTOP TRACK-CATTACHES z �. STRUT - NOTCH CEILING TILES I j� AROUND EACH ATTACHMENT LOCATION IPRM. , ' J I ",,, 1. SEE SHEETS CS1 FOR ADDITIONAL DEMOLITION WORK. u.' 4 =arli 2. SALVAGE AND REUSE EXISTING CEILING/LIGHTING FIXTURES WHERE .4 METAL STUD PARTITION PER PLAN �� /- POSSIBLE. 1 ►� BASE _ ►� =:� PT r r °� �'4, BOTTOM TRACK TO FLOOR WITH N N 100 , ; ANCHORS AT 4'-0" O.C. (MAX) AND n - —■ II ''1-- I �11, AT CORNERS AND ENDSW0_ O_ Nil t_., NOTE: WIRES TO BE CONNECTED BY LOOP AROUND STR /JOIST WITH CO CO aN MINIMUM OF (3) WRAPS OF END CNI 0• c�i ;:; ° AROUND MAIN WIRE WITHIN 3" OF a •o •o on CONNECTION N N F0i, r — 12 GA. HANGER WIRES ® 4'-0" W.u. O.Q. (rm.) TYPICAL INTERIOR PARTITION COMPRESSION BRACE, SEE SCHEDULE 3/4" = 1'-0" 092900-04B I 12 GA. SPLAYED BRACE WIRES / (TYP.) MAXIMUM ANGLE FROM HORIZONTAL IS 45 DEGREES k(11t1 CROSS TEE . MAIN TEE ifiL.0111#1.:. ‘ NORTH . DEMO RCP O FASTENER SCHEDULE 1/8" = 1'-0" CONSTRUCTION TYPE FASTENER REQUIREMENTS ARCHITECTURE WOOD 1/4" X 3" SCREW EYES III ENGINEERING STEEL DECK PRE DROP WIRES, CMI DC1 OR DC, 2-1/4" METEAL DECK SCREW EYES PLANNING POST TENSIONED CONCRETE PRE DROP WIRES, EMBEDS, 1/4" X 3/4" METAL HIT ANCHORS 11) INTERIORS CAST IN PLACE CONCRETE PRE DROP WIRES, EMBEDS, 1/4" X 3/4" METAL HIT ANCHORS LANDSCAPE COMPRESSION STRUT SCHEDULE 15895 SW 72ND AVE SUITE 200 MAX. LENGTH OF STRUT STRUT REQUIREMENTS PORTLAND, 26 97224 TEL : 5 0 3 .. 2 2 2 8 . 1 2 8 5 5,-10" 1/2' DIA. CONDUIT (EMT) FAX : 5 0 3 . 2 2 8 . 1 6 7 0 7'-8" 3/4" DIA. CONDUIT (EMT) www . CIDAINC . 00U O O n 1 '-O 1" DIA. CONDUIT (EMT) lYZ ) RCP LEGEND 12'-0" SINGLE 1-5/8" X 20 GA METAL STUD 15'-O" BACK TO BACK 1-5/8" X 20 GA METAL STUDS 1 I I 13'-6" SINGLE 2-1/2" X 20 GA METAL STUD CORRIDORI ROOM NAME & NUMBER 15'-0" BACK TO BACK 2-1/2" X 20 GA METAL STUDS I I I (E) 2X2 LAY IN ACOUSTICAL CEILING GRID PROVIDE HEAVY DUTY CEILING SUSPENSION SYSTEM CONFORMING TO THE REQUIREMENTS OPF ASTM C-635-00. I - VERIFY SUPPORTS. SEE DETAIL 11/1-1.2. REFER TO STANDARD FOR ADDITIONAL INFORMATION. COPIES ARE AVAILABLE AT ARCHITECT'S OFFICE • 2 dF •_1 Inil II l�- 10� I 10 I �I 2X4 LAY IN FLUORESCENT LIGHT FIXTURE Upr- ,. OF CE ��' 2X4 LAY IN FLUORESCENT LIGHT FIXTURE WITH r INT. OR EXT. WALL / ROOF OR FLOOR DECK N -Mf CE BATTERY BACKUP �/ �/ LI C E (E) ILLUMINATED EXIT SIGN u.� v vO OO11111 CENTERLINE OF STUD WALL AND Ir N N 1 11® CENTERLINE OF MULLION y" N R •K RM. ��NOTE 2 NOTE 6 �� I- 0 102 �■I DUCT EXISTING ALUMINUM STOREFRONT SYSTEM MULLIONla 2 La 0 att ceCT) •�! ,I 5 5 5 5 5 I O� O � ;• I RCP GENERAL NOTES I I a Y NOTE 1 r- NEOPRENE GASKET i U,r ' 1. THIS DRAWING IS DIAGRAMATIC AND FOR DESIGN PURPOSES ONLY. ALL ACOUSTICAL SEALANT OVER N • ' `RIP' DIMENSIONS TO BE FIELD VERIFIED. NOTE 4 - NEOPRENE GASKET-- ATTACH TO Z = et STOREFRONT SYSTEM W/ ADHESIVE Q Q 2. ELECTRICAL CONTRACTOR TO VERIFY MINIMUM EMERGENCY EXIT 11 '� TAPE Z = C,7 ILLUMINATION WITH BATTERY BACKUP AT EGRESS PATH OF TRAVEL - W 1- ' PROVIDE 1 F.C. MIN. EMERGENCY LIGHTING AT PATH OF TRAVEL. THIS NOTE 3 i/2" - ~ i- LEVEL MAY DIMINISH TO NOT LESS THAN 06 F.C. OVER 1.5 HOURS OF 1Op1101r Ca OPERATION. ----I-I . - I I 1a 3. CEILING HEIGHT TO MATCH EXISTING - 8'-6"± U.N.O. MAXa `V 6'-0" MAX. 4'-0" 0.C. MAX. (#12 WIRE) / / 4. CONTRACTOR TO PATCH CEILING ABOVE DEMO WALLS AND AT NOTES: K) RELOCATED LIGHTS AS NECESSARY. REPLACE DISCOLORED TILES. " �' r 1. LATERAL BRACING ® 12'-0" O.C. EACH WAY, MAIN RUNNER TO STRUCTURE. BEGIN BRACINGN. ;ilia MOM. I 5. WHEN POSSIBLE, USE SALVAGED LIGHTING FIXTURES. LOCATE ACCORDING WITHIN 4'-O" OF PERIMETER AND 2" FROM CROSS MEMBERS. I V PREFINISHED 16 GAUGE SHEET a a 2. ADDRIONAL HANGING WIRE WITHIN 8" OF PERIMETER. . I a a TO 1/T1.2. METAL CHANNEL-- COLOR TO g Nim mom 3. STABILIZER BAR BETWEEN ALL MEMBERS ® PERIMETER. MATCH WINDOW SYSTEM MEN= ONOMME 4. TRAPEZE DUCTWORK AND OTHER LARGE OBSTRUCTIONS, COUNTER SLOPE. /� 5. CONNECTION DEVICE TO HAVE 100# CAPACITY. II —,/ —_ 6. VERTICAL STRUTS AT 12'-0" O.C. E.W. N 1 ; GYP. BD. x O LATERAL BRACING FOR SUSPENDED CEILING I 3/4" = 1'-0" 095123-01A REFLECTED CEILING NORTH . i INTERIOR WALL @ MULLION PLANS 8c DETAILS 4 9 REFLECTED CEILING PLAN 1-t 3" = ,'-o" 08400-03 1-1.2 k' T1.2 1/a" = 1'-0" 0 Pi O JOB N0. 160257.01 -70:- ..q ©20113 ODA P.C./OW All marts RESERVED