Plans 1 I PITCH: 20 ARRAY PITCH:20
MP3 AZIMUTH:270 ARRAY AZIMUTH:270
c I MATERIAL: Comp Shingle STORY: 1 Story
0 0 0 I ❑
11)1 ' `"
4„,(!),_,/ , a 6
R,0 414 B
Front Of Hou ❑ LEGEND
STRUC - - -
CHA 1i1j 1) I 0 (E) UTILITY METER & WARNING LABEL
0 P 0 ° ® INVERTER W/ INTEGRATED DC DISCO
can ❑ & WARNING LABELS 1
1-,-1 DC DISCONNECT & WARNING LABELS
( ' W ��d �°f� ® AC DISCONNECT & WARNING LABELS
kTe S�ti ��j
❑ �C' 'd ,•t 0 DC JUNCTION/COMBINER BOX & LABELS
41 12' - / M
\ Iii
0° DISTRIBUTION PANEL & LABELS
sGAN
.� STRUCTURE. - -- A ❑ 1� Lc LOAD CENTER & WARNING LABELS
cn CHANGE 'Pt/18,P-
cu
Pth 8,
°' C IS H. ' O DEDICATED PV SYSTEM METER
c.
--I
(E)DRIVEWAY 12" FSB /43\
- , Expires June 30, IG[ RAPID SHUTDOWN
cn1 Inv ' ❑
CD I-„-I 0 STANDOFF LOCATIONS
CD 4'1 p1% Digitally signed CONDUIT RUN ON EXTERIOR
n L � ❑ b Chris KiCONDUIT RUN ON INTERIOR
y m GATE/FENCE
I
I Chris Ki ni Date: r01
HEAT PRODUCING VENTS ARE RED
_____LJAC J 2018.05.24 1` ;' INTERIOR EQUIPMENT IS DASHED
c
L=J
°t M 1-1 15:18:51 -04'00'
EtSITE PLAN N
TOTAL ARRAY AREA (SF): 477 Scale: 3/32" = 1' Ali TOTAL ROOF AREA (SF): 2431 w `r E
TOTAL ARRAY AREA IS a 19.62 O 1' 10' 21'
imin
PERCENT OF TOTAL ROOF AREA m..... s
J B-9724266 0 0 CUSTOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL- THE INFORMATION USED FOR THEN IDB NUMBER: MICHAEL WADSWORTH 7.93 KW PV ARRAY Spencer Fry T 5 L n
- CONTAINED SHALL NOT BE USED � aim
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 10680 SW FONNER ST
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES PORTLAND OR 97223
ORGANIZATION, EXCEPT IN CONNECTION VAN r
THE SALE AND USE OF THE RESPECTIVE (26) Hanwha Q-Cells # Q.Peak-G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. Delta # Solivia 7.6 TL SITE PLAN 2 a 5/24/2018
•0•4 k
j\ (E) RAFTER ATTACHED TO (N) STRUT NOTE: STRUTS CAN BE ANGLED IN
WITH (4) 10d COMMON NAILS* ANY DIRECTION AS LONG A THEY INSTALLATION NOTES:
�� 1. INSTALL (N) STRUTS FLUSH
(E) 2x8 ARE WITHIN 45° OF VERTICAL TO (E) RAFTERS WITH (4) 10d
Si (E) 2x4 _ 4' MAX. / COMMON NAILS.
Nm
J M 2. INSTALL (N) CLEATS TO THE
W (N) STRUTS DIRECTLY BELOW AND
iy
FLUSH.
4" � � ;°; �:�, 3. INSTALL (N) A34 CLIP WITH
-2"- 9' /4'-3" /
1..\-
� 12'-4" (N) CLEAT NAILED TO (N) STRUT �1 1'I °-45'� (8) 8d (0.131") X 1.5" NAILS.
(E) LBW + (E) LBW WITH (3) 10d COMMON NAILS* * ADD (N) STRUTS AS
SIDE VIEW OF MP3A NTS THIS STRUCTURE WILL RECEIVE (N) STRUTS NECETHAT
EACHSRAFTER SARY OWENARESUREMOUNTING
ISS A STRUT UPGRADE. (N) A34 CLIP W/ (8) 8d x 1.5" NAILS — ON HAS ONE.
MP3A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES /
LANDSCAPE 72" 24" 39" 0" STAGGERED \SO PR°kr /�/ (E) LBW
PORTRAIT 48" 20" 65" 0" c� 0 4 /� *SIMPSON WOOD SCREWS MAY
yG / / BE USED IN PLACE OF 10d
ROOF AZI 270 PITCH RAFTER 2x6 @ 24" OC ARRAY AZI 270 PITCH 20 STORIES: 1 w • COMMON NAILS. SDW-22300 FOR
/ 2-PLY, SDW-22300 FOR 3-PLY.
C.J. 2x6 @24" OC Comp Shingle `
X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. • -G• NEW STRUTS FRONT VIEW
X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS.
a"rh 8,i°1 Scale: 1/2" = 1'
CIS N
(D-
7 6
Expires June 30, I9
d�! (E) RAFTER ATTACHED TO (N) STRUT NOTE: STRUTS CAN BE ANGLED IN
431 ` (E) 2x8 WITH (4) 10d COMMON NAILS* ANY DIRECTION AS LONG A THEY INSTALLATION NOTES:
1. IN(E) 2x4 ARE WITHIN 45' OF VERTICAL (N) STRUTS
TO (E)STALL RAFTERS WITH (4) tOd FLUSH
/ 4' MAX. / COMMON NAILS.
e�� 2. INSTALL (N) CLEATS TO THE
1L k 1
(N) STRUTS DIRECTLY BELOW AND' ' FLUSH.
3. INSTALL (N) A34 CLIP WITH
415'-3" (N) CLEAT NAILED TO (N) STRUT r-45°71 (8) 8d (0.131") X 1.5" NAILS.
'\-- (E) LBW + (E) LBW WITH (3) 10d COMMON NAILS* I \
* ADD (N) STRUTS AS
• SIDE VIEW OF MP3B NTS THIS STRUCTURE WILL RECEIVE (N) STRUTS 1 NECESSARY TO ENSURE THAT
A STRUT UPGRADE. (N) A34 CLIP W/ (8) 8d x 1.5" NAILS — 1 EACH RAFTER WE ARE MOUNTING
ON HAS ONE.
MP3B X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES
LANDSCAPE 72" 24" 39" 0" STAGGERED / //j (E) LBW
- PORTRAIT 48" 20" 65" 0" // / *SIMPSON WOOD SCREWS MAY
BE USED IN PLACE OF 10d
RAFTER 2x6 @ 24" OC ROOF AZI 270 PITCH 20 STORIES: 1 / .4 _t_ COMMON NAILS. SDW-22300 FOR
ARRAY AZI 270 PITCH 20 2-PLY, SDW-22300 FOR 3-PLY.
C.J. 2x6 @24" OC Comp Shingle
X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. NEW STRUTS FRONT VIEW
X IS ACROSS RAFTERS ANDY IS ALONG RAFTERS.
3 Scale: 1/2" = 1'
CONFIDENTIAL ATHE INFORMATION HEREIN JOBJB-9724266 00 CUSTOMER. DESCRIPI1ON: DESIGN:
CONTAINEDDSHALL NOT BE USED FOR THE
NUMBER: MICHAEL WAD SWOR TH 7.93 KW PV ARRAY Spencer Fry T ' 5 L n
BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SYSIEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 10680 SW FONNER ST
PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: PORTLAND OR 97223
ORGANIZATION, EXCEPT IN CONNECTION WITH s
THE SALE AND USE OF THE RESPECTIVE (26) Hanwha Q-Cells # Q.Peak-G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV. DME:
PERMISSION OF TESLA INC. Delta # Solivia 7.6 TL STRUCTURAL VIEWS 3 a 5/24/2018
5ii0 P Offj.
4.'i= to•Gy �'
.1 1;.N
�'ch 8,
cti�/S H��t
Expires June 30,2-019
PV MODULE
5/16"x1.5" BOLT WITH
5/16" FLAT WASHER
INSTALLATION ORDER 06.242018
ZEP LEVELING FOOT MARK HOLEVersion 072.1
LOCATE RAFTER, DESIGN SUMMARY Job#9724266
ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT
_ HOLE.
ZEP MOUNTING BLOCK --aL. Ji ATTACH FLASHING INSERT TO r �.a., i1f 1. - ii.
��. (4) Design Ct�de ASCE 7-10
r _; -_, IIr,._ (2) MOUNTING BLOCK AND ATTACH
ZEP FLASHING INSERT ,�� 3 Maier !: , : t,0
O r� TO RAFTER USING LAG SCREW.
� � � Ultimate Wind Speed V-Olt 95�h 1 Fig 1609A
(E) COMP. SHINGLE r / ....c... � .
INJECT SEALANT INTO FLASHING Ground Snow Load z pg 25.0 psfASCE Table 7-1
(E) ROOF DECKING INSERT PORT, WHICH SPREADS d--
(3) SEALANT EVENLY OVER THE
5/16" DIA STAINLESS ROOF PENETRATION. gall0 WE-4, ,11j1^
2ZtI �. . .1E51"ilitii 1ih4i.ii.f __n el.F .AIgjtt :!:;;. lrf
LOWEST MODULE SUBSEQUENT MODULESMP Name MP3A MP313 MP3C
STEEL LAG SCREW INSTALL LEVELING FOOT ON TOP °°°
(2-1/2" EMBED, MIN) ....:2, � + � �4MP�'ttt�f �IRrrc�F- � � ��t �"' e ,_
(4) OF MOUNTING BLOCK & Standoff Comp Mount SRV Comp Mount SRV Comp Mount SRV
(E) SECURELY FASTEN WITH BOLT. m•
SLIRLL:PV 26.0 psf 25 O of 2ff o psf
RAFTER
0 STANDOFF SL LL..� , Ao�.a .gt _ 2 .t
Scale: 1 1/2" = 1' - ;
-. , P't ' ,i7 iii , , * .a.i'i ,�ihi; l !,€ i n
MP Name MP3A MP3B MP3C
NP+acl+ttg. 72" _� , r. ..'. €, ' -' .::
a X-Cantilever 24" 24" 2$'.
C Y Sp 1. .€';1[ -_ _
-. Y-Cantilever NA NA NA
.. ft „ • 4 . . 49"
gX-Cantilever 20" 20" 20"
Y-Cantilever NA NA NA
. tired 1Staggered igered r 3., ..
X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters.'
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9724266 0 0 CUSTOMER: DESCRIPTION: DESIGN:
- CONTAINED SHALL NOT BE USED FOR THE MICHAEL WADSWORTH 7.93 KW PV ARRAY Spencer Fry
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: T = S L n
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 10680 SW FONNER ST
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: PORTLAND OR 97223
ORGANIZATION, EXCEPT IN CONNECTION WITHa
THE SALE AND USE OF THE RESPECTIVE (26) Hanwha Q—Cells # Q.Peak—G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME: SHEET: REIt DATE
PERMISSION of TESLA INC. Delta # Solivia 7.6 TL UPLIFT CALCULATIONS 4 a 5/24/2018
GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE
BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:NoMatch Inv 1: DC Ungrounded INV 1 —(1)Delta # Solivia 7.6 TL LABEL: A —(26) anwha Q—Cells f Q.Peak—G4.1/SC305 OR # 180498
RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24 528 208 Tie—In: Supply Side Connection Inverter;7600W, 240V, 97.5%, Zigbee, PLC PV Module; 305W,279.2PTC, 46MM, Black Frame, MC4, ZEP, 1000V RGC, CGC1
Underground Service Entrance INV 2 Voc: 40.05 Vpmax: 32.62
INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
(E) 125A MAIN SERVICE PANEL
- Multiple Main Breakers (6 or fewer) Inverter 1 IND
(E) WIRING CUTLER—HAMMER ,c+
—
Disconnect DC- it '�
® Q Delta A� {—-
—•----- DC+ MP 3: 2x6 1
- . ow i •J_ B 40A Solivia 7.6 TL �_—_________,--• DGC�, ''
• • n - a 240V1 F----I �0 J
B \ L2 w� DC+ � —• - DC+
n Flint— N �� DC- IL IHA-___ •-----
•------
-.-
�. A1C
(E) LOADS }.� GND _ EGC/ w� DC+ w— �C+ MP 3: 2x7 All 1
I i■ V •
� � GEC �� --�� DC �-—--�� rC ( /I,
I • r----J I GND I----EGC--- --- — GC J
• 1 1
N I -
_L —
Al o
— T 17ECt
TO 120/ 40V
SINGLE PHASE I I A
UTILITY SERVICE
II I I
I I
I I
I
I I
_i___I—
Voc* = MAX VOC AT MIN TEMP
POI_(2)Grotirld Rod B —(1)CUTLER—HAMMER #DG222NRB A (4)Delta Y Solivia
5/8 x 8, Copper Disconnect; 60A, 24OVac, Fusible, NEMA 3R AC Smart RSS Rapid Shutdown, 600V, 20A, NEMA 4X, MC4 DC
-(2)ILSCO f IPC 0-16 -(1)CUTLER-HAMMER Y DG100NB
Insulation Piercing Connector; Main 4/0-4, Tap 6-14 Ground/Neutral Kit; 60-100A. General Duty(DG)
SSC-SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE -(1)CClasEsRR FuseEKitpSi6FK
AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(2)FERRAZ SHAWMUT#1R4OR PV BACKFEED OCP
Fuse; 40A, 250V, Gloss RK5
(1)AWG 0, THWN-2, Block (1)AWG#8, THWN-2, Black �._ (4)AWG#10, PV wire, 600V, Black Voc* =266.09VDC Isc =9.84 ADC
®Ic iE(1)AWG f6, THWN-2, Red O Ii(1)AWG AWG#8, THWN-2, Red O 6-AI (1)AWG#10, THWN-2, Green EGC Vmp =195.72 VDC Imp=9.35 ADC
(� (1)AWG f6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=31.7 MC I 1-(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=31.7 MC LLLL-�I (1)Conduit Kit; 3/4" EMT
-(1)AWG f6,.Solid Bare.Copper. GEC. . . . (1)Conduit.Kit;.3/4'.EMT. . . . . . . . . . . . . . . . .7.0)AWG f8,.THWN-2,,Green . . EGC/GEC.-(1)Conduit.Kit;.3/4'.EMT. . . . . . . . . . O���(4)AWG#10, PV Wire, 600V, Black Voc* =310.44 VDC Isc =9.84 ADC
(1)AWG#10, THWN-2, Green EGC Vmp =228.34VDC Imp=9.35 ADC
(1)Conduit Kit; 3/4' EMT
3
I
J B-9724266 00 CUSTOMER DESCRIPTION: DESIGN:
CONFIDENTIALAIE - THE IN BE USED RE THE JOB NUMBERMICHAEL WADSWORTH 7.93 KW PV ARRAY Spencer Fry T - 5 L --
CONTAINED SHALL NOT BE USED FOR THE —� —
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 10680 SW FONNER ST
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: PORTLAND, OR 97223
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (26) Hanwha Q-Cells # Q.Peak-G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. Delta # Solivia 7.6 TL THREE LINE DIAGRAM 5 a 5/24/2018