Plans (97) PITCH: 32 ARRAY PITCH:32
MP1 AZIMUTH:260 ARRAY AZIMUTH:260
MATERIAL:Comp Shingle STORY: 2 Stories
PITCH: 32 ARRAY PITCH:32
MP2 AZIMUTH:260 ARRAY AZIMUTH:260
�
. MATERIAL:Comp Shingle STORY: 2 Stories
C70 PITCH:45 ARRAY PITCH:45
- MP3 AZIMUTH:170 ARRAY AZIMUTH: 170
J MATERIAL: Comp Shingle STORY: 2 Stories
0
em
3 0 0
El 0 —
Front Of House
m
0 0 - LEGEND
N
,--1
0 (E) UTILITY METER & WARNING LABEL
® INVERTER W/ INTEGRATED DC DISCO
& WARNING LABELS
CA �- DC DISCONNECT & WARNING LABELS
N •cn 12" FSB 15.1 AC DISCONNECT & WARNING LABELS
- o MP3 0
D o 0 0 o o O DC JUNCTION/COMBINER BOX & LABELS
-o
CD (E) DRIVEWAY ° DISTRIBUTION PANEL & LABELS
o 0 0 0 o i LG LOAD CENTER & WARNING LABELS
rn
—1 o 0 IN O DEDICATED PV SYSTEM METER
CDQ a o GI Rso RAPID SHUTDOWN
--- 0 0
DM 0 STANDOFF LOCATIONS
I ---, I 3 CD
0 CONDUIT RUN ON EXTERIOR
e , ,( D ,, i -0 o 0 0 I 1 CONDUIT RUN ON INTERIOR
I GATE/FENCE
O 0 HEAT PRODUCING VENTS ARE RED
• SV OFH ® r INTERIOR EQUIPMENT IS DASHED
L-2i
.2.
G)
o�
rt
(D
SITE PLAN N
TOTAL ARRAY AREA (SF): 220 Scale: 1/8" = 1' w �,
TOTAL ROOF AREA (SF): 1991 41r E
TOTAL ARRAY AREA IS a 11.06 0 1' 8' 16'
PERCENT OF TOTAL ROOF AREA s
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER:
J B-9711477 0 0 CUSTOMER: DESCRIPTION: DESIGN:
CONTAINED SHALL NOT BE USED FOR THE HOON PARK 3.66 KW PV ARRAY Derrick Olds T 5 L n
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 13232 SW APPLE GROVE TERRACE
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES SHERWOOD, OR 97140
ORGANIZATION, EXCEPT IN CONNECTION VAN
THE SALE AND USE OF THE RESPECTIVE (12) Hanwha Q-Cells # Q.Peak-G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. INVERTER:
SOLAREDGE # SE3000H-US000SNU2 SITE PLAN 2 6/26/2018
14*
I�
(I (E) 2x4 (E) 2x4
0 0 1
11 PRE-MANUFACTURED TRUSS
STRUCTURE MEETS THE
PRE-MANUFACTURED TRUSS PRESCRIPTIVE REQUIREMENTS
STRUCTURE MEETS THE -2" I. 3'-9" -1" 7-1" OF THE OSSC SECTION 3111
PRESCRIPTIVE REQUIREMENTS
-2" II -2" '-10" 7'-5" OF THE OSSC SECTION 3111 (E) LBW
M (E) LBW SIDE VIEW OF MP2 NTS
S SIDE VIEW OF MP1 NTS e
_, MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES
MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES
LANDSCAPE 72" 24" 39" 0" STAGGERED LANDSCAPE 72" 24" 39" 0" STAGGERED
-
PORTRAIT 48" 20" 65" 0" PORTRAIT 48" 20" 65" 0"
TOP CHORD 2x4 @ 24"OC ROOF AZI 260 PITCH 32 STORIES:2 TOP CHORD 2x4 @ 24"OC ROOF AZI 260 PITCH 32 STORIES: 2
ARRAY AZI 260 PITCH 32 ARRAY AZI 260 PITCH 32
BOT CHORD 2x4 @24"OC Comp Shingle BOT CHORD 2x4 @24"OC Comp Shingle
X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV.
X IS ACROSS RAFTERS ANDY IS ALONG RAFTERS. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS.
(E) 2x6 PV MODULE
5/16"x1.5" BOLT WITH
5/16" FLAT WASHER
INSTALLATION ORDER
ZEP LEVELING FOOT
® ZEP ARRAY SKIRT 1
LOCATE RAFTER, MARK HOLE
( ) LOCATION, AND DRILL PILOT
HOLE.
Alt
� ZEP MOUNTING BLOCKa+,.� ais Y. ATTACH FLASHING INSERT TO
ATOP �,_;_; (2) MOUNTING BLOCK AND ATTACH
ZEP FLASHING INSERT `�� f� TO RAFTER USING LAG SCREW.
_____ _
PRE—MANUFACTURED TRUSS (E) COMP. SHINGLE
...74 11111101111
STRUCTURE MEETS THE r INJECT SEALANT INTO FLASHING
PRESCRIPTIVE REQUIREMENTS
!; _a" 5'_s• OF THE OSSC SECTION 3111 (E) ROOF DECKING (3) INSERT PORT, WHICH SPREADS
n` SEALANT EVENLY OVER THE
(E) LBW 5/16" DIA STAINLESS ROOF PENETRATION.
SIDE VIEW OF MP3 NTS STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES
INSTALL LEVELING FOOT ON TOP
(2-1/2" EMBED, MIN) (4) OF MOUNTING BLOCK &
MP3X-SPACING X-CANTILEVER Y-SPAQNG Y-CANTILEVER NOTES
(E) RAFTER SECURELY FASTEN WITH BOLT.
LANDSCAPE 72" 0" 39" 0" STAGGEREDSTA N D O F F
PORTRAIT 48" 20" 65" 0"
TOP CHORD 2x6 @ 24"OC ROOF AZI 170 PITCH 45 STORIES:24/01
ARRAY AZI 170 PITCH 45
BOT CHORD 2x8 @24"OCComp Shingle
Scale: 1 1/2" = 1'
X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV.
X IS ACROSS RAFTERS ANDY IS ALONG RAFTERS.
J B—9 7114 7 7 0 0 CUSTOMER DESCRIPTION: DESIGN:CONFIDENTIAL- THE INFORMATION HERON JOB NUMBER: HOON PARK 3.66 KW PV ARRAY Derrick Olds
CONTAINED SHALL NOT USED FOR NE T = 5 L n
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 13232 SW APPLE GROVE TERRACE
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES SHERWOOD OR 97140
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (12) Hanwha Q-Cells # Q.Peak-G4.1/SC305 PAGE NAME: SHEET: REV. DATE
TESLA EQUIPMENT, WITHOUT NE WRITTEN �� :
PERMISSION OF TESLA INC. SOLAREDGE # SE3000H-USOOOSNU2 STRUCTURAL VIEWS 3 6/26/2018
06.26,2018
Version#73.5
DESIGN SUMMARY Job#9711477
Design Code d ASCE 7-10
.`. A.. Iorta .* ctc €; < ` .1.. 1.6
Ultimate Wind Speed V-Ult 115 mph Fig.1609A
xi3stir i� =
Ground Snow Load pg 25.0 psf ASCE Table 7-1_
cit` , 17E1T
MP Name MPI MP2 MP3
.Ring #hoof f Root
5 Standoff Comp Mount SRV Comp Mount SRV Comp Mount SRV
SL/RLL:PV 25.0 psf 25.0 psf 25.0 psf
G • PV' 20404mAr
MP Name MP1 MP2 MP3
X-Cantilever 24" 24" 24"
Y-9lsaatng' 39" ;..39" 3€.
V-Cantilever NA NA NA
sing 211, 44" ; :x' ¢"
`gy,pp X-Cantilever 20' 20' 20
o 12- Y-SR ng' = _.. �.>,
Y-Cantilever NA NA NA
Layout iii# _ Staggered 9 _
X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters.
•
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9711477 0 0 CUSTOMER: DESCR1PnoN: DESIGN:
CONTAINED SHALL NOT BE USED FOR THE HOON PARK 3,66 KW PV ARRAY Derrick Olds T - 5 L n
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 13232 SW APPLE GROVE TERRACE
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES SHERWOOD OR 97140
ORGANIZATION, EXCEPT IN CONNECTION WITH 1
THE SALE AND USE OF THE RESPECTIVE (12) Hanwha Q—Cells # Q.Peak—G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REM. DATE
PERMISSION OF TESLA INC. SOLAREDGE # SE3000H—USOOOSNU2 UPLIFT CALCULATIONS 4 6/26/2018
GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE
BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:HOMC3OUC(200A) Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE ## SE3000H—US000SNU2 LABEL: A —(12)Hanwha Q—Cells Q.Peak—G4.1/SC305 OR # 180498
RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:34 600 374 Inverter; 3000W, 240V, 99% Inverter; 3000W, 240V/208V, 99%; HD Wave w/Jnifed D13KoMa kilfa ,279.2PTC, 40MM, Black Frame, MC4, ZEP, 1000V RGC, CGC1
Underground Service Entrance INV 2
Voc: 40.05 Vp m a x: 32.62
INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
(E) 200A MAIN SERVICE PANEL
E) 200A/2P MAIN CIRCUIT BREAKER Inverter 1
(E) WIRING CUTLER—HAMMER ^
200A/2P Disconnect �`l SOLAREDGE
� SE3000H—USOOOSNU2
lI (E) LOADS A
i\ LI I240V,
• 1 I L2
III I� N --
20A/2P 1 _ _
GND - EGC/ DC DC MP1,MP2,MP3:
IR a .__IL
I ---��� b GEC i1 �- DC- DC- 1X12
• B I I GND I---_EGC EGC U
r
U
N
J EGC/GEC j
z-z
CD
— T GEC
r 1
TO 120/240V I
SINGLE PHASE I I
UTILITY SERVICE I I
I II I I
I
I I
I I
I I
Voc* = MAX VOC AT MIN TEMP
POI—(1)SQUAakeRE r D !A H 220 Spaces PV BACKFEED BREAKER A —(1)CUTLER—HAMMER /DG221URB
Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R ^/y Pv —(12)SOLAREDGE /P400-5NM4MZM
PowerBox Optimizer;400W, ZEP DC
Bre2
—(2)5owidRod —(1)B x 8, Copper GrroouEnd/Neutraall Kit;D330A, General Duty(DC)
O—(1)AWG#10, THWN-2, Block (2)AWG#10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC
§—(1)AWG#10, THWN-2, Red O[if(1)AWG#10, THHN/THWN-2, Green EGC Vmp =350 VDC Imp=10.32 ADC
(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=12.5 MC (1)Conduit Kit; 3/4' EMT
. , , . , .-(1)ANG#6,.THWN-2,.Green . ............................Kit;.3/4'.EMT. , . , , . . . . .
I
1
CONFIDENTIAL— THE INFORMATION HEREIN JOJ B-971 147 7 00 CUSTOMER DESCRIPTION: DESIGN:
JOB NUMBER: HOON PARK CC
CONTAINED SHALL NOT BE USED FOR THE 3.V V KW PV ARRAY Derrick Olds T . 5 - n
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 13232 SW APPLE GROVE TERRACE
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES SHERWOOD, OR 97140
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (12) Hanwha Q—Cells # Q.Peak—G4.1/SC305
TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET REV: DATE:
PERMISSION OF TESLA INC. INVERTER:
SOLAREDGE # SE3000H—USOOOSNU2 THREE LINE DIAGRAM 5 6/26/2018