Loading...
PFI2018-00151 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00151 06/20/2018 P: 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: SEGO Parcel: SEG446 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 446. Replace install new sidewalk brace on Pole 12066; install new underground service to 6 lot partition. pGE Jobs: M2520796&M25112874. Owner: FEES Description Date Amount PHONE: Contractor: TFT CONSTRUCTION INC 53990 WEST LANE RD SCAPPOOSE, OR 97056 PHONE: 503-543-7979 FAX: Applicant: TOD SHATTUCK 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-612-2935 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application :111Issued By: �-- % & Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00151 Type: Condition Name: Status: SeverityL PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services:503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice FRECENED City of Tigard Tyr PUBLIC WORKS ENGINEERING SUN �. 241$ � wo „E IGARD � Public Facihtylmr%rovemerit (PFI) 1�99UVGINEERING TYPE OF WORK DESCRIPTION OF WORD(in the right-of-way) VX TYPE 1—Franchise Utility Work Check one: 5/Utilities ❑Sidewalk/driveway approach ❑ Street improvements performed by NWN, PGE Detailed description: Replace install new sidewalk brace and/or utility agency. on Pole 12066; Install new Undergound Service to 6 lot partition ❑ TYPE 2—Sidewalk/Driveway/Sewer PGE Jobs M2520796& M2512$74 Work performed for the purpose of: Sidewalk installation or repair. ° Driveway approach installation About 8835 SW Thorn Street Property address/location(s): and/or repair S 4LAlQ Tigard, OR 97223 o Sanitary sewer lateral installation and/or main line tap Applicant: Portland General Electric [Submitted by Amy Sweany] ❑ TYPE 3—Full scale Development Work performed with Land use Address: 10800 SW Avery Street approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: 503-612-2935 Email: preregcoord@pgn.com o Subdivisions or Partitions Contact name: Tod Shattuck Phone: 503-672-5466 ° Street widening o Mainline installation for Sanitary Contractor: TFT Construction sewer, Storm sewer, Tigard water and/or Tigard Water Service Area CCB#: 104648 Expiration: Address: 53990 WEST LANE RD SUBMIT COMPLETED APPLICATION TO: City/state: SCAPPOOSE, OR Zip: 97056 City of Tigard 503-464-7777 marc@tftconstruction.net Planning/Engineering Phone: Email: @ 13125 SW Hall Blvd. Contact name: Marc Johnson Phone: 503-543-7979 Tigard,OR 97223 Applications for"minor work in right-of-way" only may be emailed to: Engineer: NIA romTermitsktigard-or.gov Address: nmB ffmw un Omly City/state: Zip: Phone: Email: Case No.: W`Q-0 18—DD�5 Contact name: Application submittal fee(.007%of Engineer's Estimate) $. Estimated value of work is required(if over$5,000):$ 13,249.87 Additional fees: (within the public right-of-way) Application accepted: Is work related to a LAND-USE DECISION? El Yes L�No By. L- Date: If so,please specify (MI.P,SDR, SUB, etc.) case #: ApplicatiPf reviewed: By: Date: - Is work related to a BUILDING PERMIT? ❑ Yes Mf No Applicant notified: If so,please specify(BUILDING PERMIT)case#: By: Date: I:\ENG\PermitApplications\pfi_application Rev.10/16/2017 City ofI'igard a 13125 SW Hall Blvd. o Tigard,Oregon 97223 www.tigard-or.gov o 503-718-2421 o Page 1 of4 APPLICANTS NO'T'E: Person specified as "Applicant"shall be designated"Permittee" and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the Cit}'of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner.. The owner(s)must sign tivs application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owners signature on the application BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that maybe attached to or imposed upon the subject proper • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denyingthe application. /I h ® Digitally signedy Vinh �/ D Nguyen,PE Nguyen, P_E Date:2018.06.15 2.36:7-)-(Lnn' Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard ° 13125 SW Hall Blvd. ° Tigard,Oregon 97223 • wwwtigard-or.gov 503-718-2421 0 Page 2 of4 DEVELOPMENT ENGINEERING FEES • . STAFF O NLY Public Facility Improvement(PFI)Permit: DETAILED REQUIREMENTS APPLICATION FEE Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECT`IONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5%(less$300.00 minimum Sketch submittal fee) (including information below) Engineer's estimate X 2%Plan Review ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk.repair(less than 20 lineal feet) (6 sets,24x36 or 2204). • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General-Notes(City,Water;Sewer;etc.) • Weep hole repair Ej Street*(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑. Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting E Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility.Plan(Electrical,Phone,.Gas, Storm,Sanitary;Water,Signage,Street Lights,etc) ❑ Details. Note: A cash/bond assurance may be ❑ Traffic Sight Distance required pet TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • ww�aigard-or.gov • 503-718-2421 • Page.3 of4 SAMPLE SKETCH: a q .itch. i' u ' ii��.i.g't t r�....®.a. a®e Mom a as a ars a a�� .,aa►. �' � J+� Hie�,,E.�• 'r re -� 0 1 70�71_111VPOSIM m!L—e—rr,—nr— r Existing �A CL OL r e � I 7 i� IML Pvoiedpole 93 e i F{fE+ Hydrant(FH) MINIMUM SKETCH REQUIREMENTS (Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street & street name(s) Existing building, structures Utility& street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. a Tigard,Oregon 97223 . wtvuTtigard-or.gov ® 503-718-2421 - Page 4 of4 OVERHEAD LEGEND n40 6830 • REMOVE FACILITIES =1 INSTALL FACILITIES 3026 0020 8616 WI() P808 z ANCHORS 7C LEAD CO LBS • ANCHOR CODE AIIA3lA5lA7lA8j 108130 pl. em 0835 B SIDEWALK ,ALK BRACE GUYING ; 03 # Ci Ci (POS.-LBS.) z z, G19 SECONDARY @ 9,647# S! A410AL-TX I GUY GI G4 G7 GI GI GI 22 12065 A 50 8807 40'-4 2 GUYS G21G51G8IG111 2C�231 1" 12066 _. -___. .196.91. X 6132 40'-4 3 GUYS G31G61G91G74GI G2 40'-' ID58 C1135A SW THORN ST CONSTRUCTION NOTES: OH ------ 1. SEE THE PGE ELECTRIC SERVICE REQUIREMENTS(ESR)BOOK FOR THE FULL SET OF REQUIREMENTS,THE ESR BOOK CAN BE FOUND AT hffpsj;~.poWordgeneM1.com 2. CUSTOMER IS RESPONSIBLE FOR OBTAINING ALL BUILDING AND ELECTRICAL PERMITS FOR THE APPROPRIATE MUNICIPALITY.CUSTOMER IS ALSO RESPONSIBLE FOR OBATINING ALL EASEMENTS AND TREE-TRIMMING PERMITS,AS REQUIRED. 'NG POS.-LBS.) 2 G� 3 G W 3. ALL TREE TRIMMING IS REQUIRED TO BE COMPLETED PRIOR TO PGE INSTALLING SERVICE 4. CONTACT PGE SERVICE COORDINATOR IN ORDER TO RECEIVE AN APPROVED METER SPOT AND CONFIRM THAT THE SERVICE WILL MEET ALL APPLICABLE CODE CLEARANCE a- REQUIREMENTS OVER GOUND,STREETS,PARKING LOTS,ROOFS, DECKS AND BALCONIES, ACROSS OR BESIDE OTHER OVERHEAD UTILITY WIRES,AND ADJACENT TO WINDOWS. 8770 5. AFTER PASSING THE APPROPRIATE MUNICIPAL ELECTRICAL INSPECTION, 8F,20 CUSTOMER TO REQUEST AN INSPECTION BY PGE BY CONTACTING A SERVICE COORDINATOR AT 800-542-8878 OR 503-323-6700 IN THE PORTLAND AREA.PGE WILL NOT ENERGIZE THE SERVICE UNTIL ALL INSPECTIONS HAVE BEEN PERFORMED. RIGHT-OF-WAY PERMIT NOTICE: PUE CONSTRUC775R 15EMNG A PERMIT FROM THE LOCAL JURISDICTION IS REQUIRED BEFORE ANY AS—BUILT VERIFICATION & NESC VIOLATIONS CORRECTED WORK IN THE RIGHT-OF-WAY MAY BE PERFORMED. ONLY PGE APPROVED CONTRACTORS AND CONTRACTORS WHO HAVE MADE OTHER SPECIAL This document accurately represents FIELD Construction. AGREEMENTS WITH PGE WILL BE ALLOWED TO WORK UNDER PGE'S PERMIT. SAMY Foreman, Date: THE CONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION 48 HOURS I RM General Foreman: BEFORE WORK IS TO BEGIN,A COPY OF THE PERMIT MUST BE ON SITE. Date: (Signature only required for field construction changes.) SDPMIENG REVIEW. — =BUILT BY DESIGNER: =011NO CONTACT SERVICE COORDINATOR DATE: 59/2018 SCALE: NTS rACCOUNT_, 7070001 AWO: 100000454=5 M2520796 FOR TRENCH AND CONDUIT INSPECTION PRIOR TO BACKFILL.PGE WILL NOT INSTALL MILE TITLE UNTIL TRENCH IS 100%BACKFILLED. REPLACE AND RELOCATE WITH SIDEWALK BRACE SERVICE COORDINATOR CIRCUIT 503-323-6700 OR 800-542-8878(SALEM) /P WEST-PORTLAND NORTH =71.7 7 CALL 811 BEFORE YOU DIG P y LOCATION ATTENTION: 8835 SW THORN ST TIGARD OR 97223 OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER. DESCRIPTION THOSE RULES ARE SET FORTH IN OAR 952-001-0010 RELOCATE ANCHOR& INSTALL SIDEWALK BRACE THROUGH 952-001L-W90.YOU MAY OBTAIN COPIES OF COUNTY ISECTION(S) WORK WITH SHEET THE RULES BY CALLING THE OREGON UTILITY WASHINGTON I C1135A M2512874 NOTIFICATION CENTER ADMINISTRATION @ (503-232-1987) BEAVERTON I — I OFI LINE CREW CENTER DESIGN By PHONE(503) DRAWN BY TO REQUEST UTILITY LOCATES CALL THE OREGON Know wheffs below. 2213 SW 753RD- I TOO SHATTUCK 672-5466 1 SUJATHA NARAYANAN UTILITY NOTIFICATION CENTER,811 AT LEAST Call before you dig. BEAYERTON oR P7006 2 BUSINESS DAYS PRIOR TO EXCAVATION. PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED Page 84 2011 Edition �, �6742 Stattonary�Lane Closure with FIlagging ce � Di'agrarrm45 - ..A 'r ... -r -_n ,e:._-;,;a -i�z'aa*-Snr"� c ,eJ. .7 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic'volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the"Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 kn o v C � c m m aa. N Ir px ------------------------� oN (D n Cr (Jt Q Single Flagger Operation I ' Z. I for Low Volumes (Optional) off," a Pf"IV cn w vj a (ADT<400) To s,nF � 0 0 o n BE {d FLAGGM ONE LANE ja Zi ca I A B B c PREPARE DROAD ° - H H H I TO STOP i CL O Cwti O W'�WJI i' t mile -� ROADeg cn �- '�' � � _► ilk � �'• � WORK s rQ -' 3 I I c I B K e K A I--I I AHEAD O in o 0 o f1 wi cn I BuRew TAN MothV013"W q �T57, I Yom, t PREF _ To srov IQ � roan Ul W C,71 N O J y�€ •••• AVQM A B B C J. V pa p O O O O UT O O n ye J. 0 CL Ppftv� ejp0 ------------------------� ..o cD XI I 1 mile max. .: m;r« • {Q 3"S • •• 3� y 1l�ya y � • • � • � vr x B B A Buffer �T 3 Protection Vehicle ' -- w/TMA(both Optional) L .� ROAD ® See Chapter 4 WORK AHEAD tDM BE ONE LANE PREPARED ROAD TO STOP Two Flagger Operation Q' AHEAD ', � iii' ro m ,IV U, (Optional) p, co • -- - SUBDIVISION LEGEND 8830 8826 -- NEW PGE FACILITIES TO BE INSTALLED 8820 - 8816 8810 - (UNLESS OTHERWISE SPECIFIED) 8840 0 A 25 62263 REMOVE FACILITIES E=- INSTALL FACILITIES - Q PD '_- _ 8808 m 644.PGE PADMOUNT VAULT,WITH 64-332P-2125-PGE TOP a ^ PROVIDED&INSTALLED BY CUSTOMER OD INSTALL V 512E FUSING CUTOUT NOTED 3 10831 -120240V---- 120240V.___ __ 1730 SECONDARY VAULT, Ln • 200AMP 200AMP ® PROVIDED&INSTALLED BY CUSTOMER INSTALL 2"POLE CONDUIT UNIT 0.4%VD 0.5311,VD WITH 142 GO F 6 T 1.22%FLKR@3T 7.60%FLKRCu)37 &LIGHTNING ARRESTER 8128A AFC 5835A -AFC PROVIDED 2 PVC CONDUIT 8 INSTALLED BY CUSTOMER ' -------- INSTALL 14350 AL-TX SECONDARY IN 1.3"PVC CONDUIT PROVIDED&INSTALLED BY CUSTOMER .-_.-.__-. ----- INSTALL I-110 AL-TX SECONDARY IN 1-3"PVC CONDUIT p Q a 2'" B � 10860 88354 5 6 PROVIDED&INSTALLED BY CUSTOMER C Q y CONDUIT I Z 3 0- —CUSTOMER TO INSTALL 3"PVC CONDUIT&STUB-UP U FOR FUTURE 1+10 AL-TX SERVICE N C4 ��y;'� CII-35A _-- a PL•d�32 _4 I -- DO WITH TDCNT WO#M2520796 __. A 50 ! =' i VT 11592974DO WITH SLCST WO#M251 A 40 AL TX 8850 PD 157 - - 142F6T O --------------------------------- - \ ------ b 330' --------------------- - _ 100 A 50- 07 - __ _ ", = _ VT 167 '. i CONSTRUCTION NOTES: RSDEV 6732 012065 -' 40'-4 - ----VT-758 40=4 1ZO66O � 1.CUSTOMER TO PROVIDE All TRENCHING AND BACKFILLING.JOINT USE TRENCH 1958 1969 10915 WITH GAS,TRENCH TO BE 48 INCHES DEEP AND 30 INCHES WIDE,MEASURED FROM ----- FINAL GRADE. -----_ -. 1969 ------— _.._._._ 2.J PGE STANDBY CREW IS REQUIRED FOR OPENING ALL ENERGIZED PGE VAULTS $W THORN ST `-----------. JUNCTION BOXES.AND STRINGS. CALL SE ES,INCLUDING CONNECTION OR 6700ALLAT ON OF CONDUITS AND PULL STRINGS.CALL SERVICE COORDINATION AT 503-323-6700 TO SCHEDULE A PGE STANDBY CREW. _.._ AL 1 3 AL P CONDUCTORS TO BE NSTA ED IN GRAY,SCHEDULE 40 ELECTRICAL TH NYLO UL STIR _ I -�y ''-" - AIN.500 UBS.TEST) PGE%DETERMINE THE PV CONDUIT ISIZE AND NUMBER OF CON DURS REQ RED. -.. __ --- - - - --1-- — REMOVE 1--121/� MAINTAIN 12 VERTICAL INCHES AND 24 HORIZONTAL INCHES CLEARANCE BETWEEN 110'I GAS AND OTHER UTILITIES.ALL ELBOWS 41NCH a SMALLER TO BE 36 NCH RADIUS. OH SERVICE ALL BENDS MUST BE FACTORY MADE.ALL ELBOWS LARGER THAN 4 INCH TO BE I _ _ 60 INCH RADIUS,RIGID STEEL OR PGE APPROVED,FIBERGLASS BENDS ARE REQUIRED ( FOR RUNS OF 151 FEET OR LONGER OR FOR ANY LENGTH RUN WITH MORE THAN l`\ - 180 DEGREES IN BENDS.PVC SCHED LE 40 BENDS ARE ACCEPTABLE FOR TOTAL BENDS IN ANY CONDUIT RUN IS 2 OU DEGREES - 1NS OF 50 FEET OR LESS.THE MAXIMUM T ES 8770 VT i2i26 10950 8850 C 50 70053 I 4.FROM PRCUSTOMOPERTY LNEBTO PROPERTY LINELE FOR ROAD .USE ONLY GRAYSINGS.ALL ,CROSSINGSC EDU EMUST EXTEND 88201 ELECTRICAL GRADE,PVC CONDUIT.CROSSINGS TO BE 48 INCHES DEEP,MEASURED ❑MLC COIVVERSfON FROM FINAL GRADE. • TO 8770 SW THORN ST 5.DIRECTIONAL BORINGREQUIREMENTS:BLACK HDPE(HIGH DENSITY POLYETHYLENE) DUCT OP.SCHEDULE 40 PVC WITH A MECHANICAL CONNECTION(CERTA-LOK OR LIKE MECHANICAL '- CONNECTION PRODUCn AS AN ALTERNATIVE TO HOPE DUCT.HDPE SHALL MEET THE_ REQUIREMENTS OF PGE SPECIFICATION LC20515(AVAILABLE ON REQUEST FROM PGE PROJECT -- - -- MANAGEF FOR SAFETY REASONS THE DUCT SHALL BE BLACK WITH THREE EQUALLY SPACE EXTRUDED RED STRIPES(WHICH IS A SPECIFICATION REQUIREMENT MANDREL TEST OF HOPE PIPE IS REQUIRED AFTER INSTALLATION WITH PGE INSPECTOR PRESENT. PD-157 O A PHASE 6.CUSTOMER TO PROVIDE AND INSTALL 0644-PGE VAULT WITH R64-332P-2125 COVER, UTILITY VAULT MODEL OR EQUIVALENT FOR PGE PAD MOUNT TRANSFORMERS. RIGHT-OF-WAY PERMIT NOTICE: STALL: PADIVAULT TO BE SET AT FINAL GRADE(SEE DETAIL ON SKETCH). A PERMIT FROM THE LOCAL JURISDICTION IS REQUIRED BEFORE ANY 7.ALL PGE TRANSFORMERS TO BE INSTALLED 8 FEET MIM FROM ANY COMBUSTIBLE WORK IN THE RIGHT-OF-WAY MAY BE PERFORMED. ONLY PGE APPROVED 1 P 7.2 2401 120 PM 50 KVA NTLB PGE OITRANSFORMERS MWALL OR EU TABE WITHIN 15EFEETIIOF AEORNEABLE OM ANY R E�RANT, CONTRACTORS AND CONTRACTORS WHO HAVE MADE OTHER SPECIAL ON 644-PGE PAD MOUNT VAULT ALWAYS MAINTAIN 10 FEET CLEARANCE IN FRONT OF ALL TRANSFORMERS. AGREEMENTS WITH PGE WILL BE ALLOWED TO WORK UNDER PGE'S PERMIT. 7 CUSTOMERS B.STEEL BARRIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED THE CONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION 48 HOURS ESTIMATED PEAK 24 TO VEHICLES. BEFORE WORK IS 70 BEGIN.A COPY OF THE PERMIT MUST BE ON SITE. 9.ALL SWITCH VAULTS TO BE SET AT FINAL GRADE WITH 61NCH GRAVEL BASE AND LOAD:35 KW CONDUITS ALIGNED TO ENTER THE VAULT END LOWER KNOCKOUTS(TERM-A"DUCTS) (SEE DETAIL ON SKETCH) W.FRONT LOT PUBLIC UTILITY EASEMENT(P.U.E.)TO BE 8 FEET(MIN PGE H1730-18 CARSON BOX TIER 22 6x4x4 VAULT WITH 3"TERMi-DUCTS 10FEET(PREFERRED). FOR DRIVABLE SURFACE W/rRANSFORMFR 11.ESTIMATED Da AMPS MOTOR STARTING CURRENT FOR FLICKER CALCULATIONS. CONTACT PGE FOR APPROVED MANUFACTURERS OPENING M TRANSFORMER PAD MUST FACE TRANSFORMER LOADING AND VOLTAGE DROP CALCULATIONS BASED ON 00 KW SrItEEt SIDE OR PARKING AREA. PER RESIDENCE. coNOurt MINIMUM CLEARANCE FROM ANY5tlBLE 12.CONSULT WITH PGE REPRESENTATIVE 2 WEEKS BEFORE STARTING MAIN POWER MaaKEa STRUCTURE R B'FROM SIDES AND BACK BAGC OF TRENCHING FORA PRECONSTRUCTION CONFERENCE.INCLUDED IN THIS CONFERENCE FINAL GRADE ON HARD SURFACE(FLUSH) VAULt WRH TO'CLEAR SPACE M FROM WILL BE EXCAVATOR,PGE,TELCO,CATV,AND GAS. T P.C.C. COVER OF VAULT. ARKED'ELECTRIC' T=GRADE WHEN CLOSER 13.DESIGN IS BASED ON STANDARD UNDERGROUND EQUIPMENT.NONSTANDARD ^UST TO INSTALL THAN Y TO A HARD SURFACE TO THE CUSTOMER UIPMENT MAY BE AN OPTION AT AN ADDITIONAL COST 2&A7h:RouND Roo IH-1 sLEF SIDE ' POVIOEC 6v Pr•E //`ANAL GRADE WHEN IN LANDSCAPE AREA J' ELECTRIC i� ���� �� Ct_I I MH' - CONCRETE I J0. r APRON 4' L TOP VIEW - wccErxe Lo AnoNs C RAOIDs9tEL80WS ►RIMARY a sECAIIONS FANY DEVIATION FROM THiS DESIGN MUST SCM 40 PVC WIFACTORV BENDS % h ee.. � 0� Ducrs(BOTH ENDS) E APPROVED BY PGE PROJECT MANAGER ST LT - pyL TO SERVICE A1AP,A',CHP h Sl ONDAR O O OPTIONAL - INSTALL 50(IR FULL STRING,EXTEND �E Q • PAST ENy OF CONDUIT UN—_.— urOFWELLCOMPACTED o ��—•Z'•CONDun - PGE CONSTRUCTION DRAWING EARTH 31/"MINUS BACKFILL 6' TRENCH SIDE VIEW UNDER SPLICE BOX \ (PRIMARY-FIELD SIDE ONLY) °I HINK. _ AS-BUILT VERIFICATION & NESC VIOLATIONS CORRECTED ?,"MINUS CRUSHED RCK'K '�' �B��S�LV�Yil� This document accurately represents FIELD Construction. 1 CONCRETE APRON SURROUND 6„DEEP(�) T MIN. Foreman: Dafe: 1' FIRSTI General Foreman: Date: PD 757 (Signature only aired for/tell construction Ghon es. 3'TO 1 A.SCHI 4o P\rr 1 1' 3"CONDUIT TRANSFORMER FOP.PERMSVC_ (SECONDARY-STREET SIDE ONLY) SDPMfNG REVIEW: JASBUILT BY DESIGNER: CONTACT SERVICE COORDINATOR DATE 6162078 scAtF:NTS JACCOUNT.7070001 AWO:7000004596 F01 NO.M2512874 (, I Red u& 21' y�4 gl4r. FOP iPENCH AND CONOUR INSPECTION PPIOR TO BACtTfLI.PGE WILL Not INSTALL WIRE TITLE _ uNrR raENaIC I.s IRR:BACKFULED. THORNWOOD MEADOWS LEGEND SERVICE OORDINATOR CIRCUIT 511E m TRENCH 3.5" cam. Tr<�e TYPE 0 c..valw�. 303-323-6700 OR 600.542-8B1B(SALEM) N. WEST-PORTLAND NORTH 17x22 GROUNC� 2p• U- RO[` APRON COLLAR TOP VIEW LG24515.2 H PGB^�bt�ti4 ATTENTION- CALL 811 BEFORE YOU DIG PGE I.T(ON PTIONAL STREET SIDE Twee° 1.. Dom, OREGON UW REQUIRES YOU i0 FOLLOW RULES ADOPTED 'f'�`~ X,.1 ` 8835 SW THORN TIGARD WASHINGTON 97223 RL O TNro/GTV BY THE OREGON U17LITY NOTIFICATION CENTER. F„y DESCRIPTION ALL SECONDARY VAULTS TO BE INSTALLED ON PROPERTY LINES WITHIN THE ®egmu THOSE RULES ARE SET FORTH IN OAR 952-001-0010 ,yT ,.5 • NEW UG SERVICE 70 6 L07 SUBDIVISION THROUGH 952-001-0090.YOU MAY OBTAIN COPIES OF COUNTY ECTION(S) WORK WITH SHEET UTILITY EASEMENT AND WILL FINAL GRADE.ALTERNATE LOCATIONS MUST BE APPROVED E PGE AND WILL BE NOTED ON THE SKETCH.THE COST FOR D ' "D THE RULES BY CALLING THE OREGON URLITY WASHINGTON C1135A M2520796 1z" a'•M10 Ueelm..6.4 NOTIFICATION CENTER ADMINISTRATION @ (503-232-1987) BEAVERTON r OF I RELOCATION OR ADJUSTMENT OF A SECONDARY VAULT WILL BE THE aw: '.E.nB LINE CREW CENTER DESIGN BY PHONE(503) DRAWN BY RESPON ROVA Y'OF THE BUILDER OR DEVELOPER REQUESTING THE MOVE. 61t" 2f" i0 REQUEST UTILITY LOCATES CALL THE OREGON Knw wllBfrs below. 22n sw W.oR TOD SHATTUCK 672-5466 SUJATHA NARAYANAN PGE APPROVALS OF INSTALLATION WILL BE BASED ON FINAL GRADE AND 7,m,V-R1.Ieu..T— UTILITY NOTIFICA77ON CENTER,871 AT LEAST Call bolero W d NA�erw. Prove LOCATION CRITERIA SET BY THE DEVELOPER AND HIS OR HER AGENT. 2 BUSINESS DAYS PRIOR TO EXCAVATION. T IB• 0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED