Plans (83) M .- C\.-. cc);:).- i_c 1 � `'., S 4v I.e-.1cl 1 ‘.::ThLEGEND: /" �/
- ss SANITARY SEWER Pacific
I� _l_I -- Jli �� ' I I II I ' J SD STORM DRAIN Community�
'+ L -w Design
�� ���.� - WATER LINE
,� _
� 12564 SW Main Street
— MANHOLE Tigard,OR 97223
\,.,, ,''a') �r CATCH BASIN [r]503-941-9484
ti DATE: 6/8/2017
3.00' ALLEY MN. TRACT M \. REv]s]oNs
PUE, TYP.
332.5 5.00' 331.8
STREET LIGHT NO. DATE DESCRIPTION
-
X11..1..._—_
_ STRAW WATTLE PERIMETER
r�� -17- _ -- ----�-,� - 1 FJ- -I-- I F oy EROSION CONTROL
_ _ I
1 i i �* FLOW DIRECTION ARROW
I
0 1 5.00' 1 I
�- -_ GARAGE .1 ~ 5.00' I
IIII--- I STREET SECTION, SEE
I
1 CONSTRUCTION DOCUMENTS
—_____ __. 4___ ___ , .�, ___
1
_ _ �� =
.� — ----333
_ 335 _
34 '
t i - - -- L -- .335 1
___ __ ______185 Iw~..-.--- - 337- ._ I — SETBACK SUMMARY
_. 1 -. __._338 _. - I� 1
�; = _ 186 - z,560 _ I _ 1 FRONT SETBACK: 12'
_ 183__..._
__..._ . __.._._ ___7 ._..1..~ -._-- I
LI 1 I o BUILDING: _ �! 184 I �� SIDE SETBACK: 3'
IJ T I /1 ,� 60BR ; 1 T t I STREET SIDE SETBACK: 8'
I .. if
I _ FRONT PORCH SETBACK: 8'
I /
II-[1'
UFF=342.8 ! I II REAR SETBACK: 3'
' I� II GFF=332.6/
1 t
6.N I I 1 I' I
1 11I 1 I I t
6.00'
O L
os 0r PUE, TYP._ •J �;o , PORCH-- lihpi J I Lt
LOT COVERAGE:
L— 17.00' I— — - RIVER
,---= - - - - - - - - - -
13.00'
�, — — — — — LOT AREA: 2,560 SF
°° TERRACE
w - _ a a 3240' � �,. _ _Q - �- FOOTPRINT:
_ n c i - 6 BUILDING 1,270 SF
�, 341.0 _. N 340.6 ,, N EAST
III
— COVERED PORCH: 121 SF
co
milli
METER STORM LATERAL
COVERED REAR PATIO: 0 SF
I° ss a s a si/ h I ss I s5 CANTILEVER LIVING SPACE: 0 SF LOT 185
(1) YELLOWWOOD/
CLADRASTIS KENTUCKIA SANITARY LATERAL DECK AREA: 0 SF PLOT PLAN
c6 SDI PSD SD SD
cA
IITOTAL COVERAGE: 1,391 SF
t II MI
_ — SW FIZIENDL\ LANE 54.3 %
Q !!ate � IMPERVIOUS AREA: 1,143 SF
O_
E
Iv
oU
O
a POLYGON NORTHWEST (503) 221-1920
a
a C395-041
2 S 1 W 6 TYPEECT NO .: CONSTRUCTION
Q
CI
SCALE REVIEWED BY: PRE
0 LOT 185 (R-25, SMALL) 10 20
45
RIVER TERRACE EAST
16873 SW FRIENDLY LANE 1INCH=20 FEET
CD v Co
n m o . cm Om
a )3 00 OO y
y - y\ 0 1�r Oz aW rm0
m ? W O Z
-0 O
o Z
v
m
v Doo
n Ei m
c o a o co
cl co opo . 62.0"
3 � m
CD C.T1
S-0" 4'-0' 53'-0" 4'0
3
C __
2
m m m m 7 -
C C C C �- I
co, w ^? m CD ro N 1 K arm
m , /
ig et_st j ._.ktip.... jr—...•1793 ' a
= v m-ixv D \
d
HHHHHH
v�-1 gz��m [� \ , i I0- M �Y \W mnmz \ /, i 1 9'
vCpo a \cn z< W
NIPHI
-ipr- . ;�
)
7 Q ! �/
�•a) -lom x-xm mo 4 . - . D2 Li „.. , y 1 to- 0 C
='"'"I‘ / /// ' \
Po iikailla , .. 1 li ' ; ' ..d „ ... NI , a
D1 - - El
XO
0 ;I Aid°
4'-0' I 5V-0° 14'-0'
N 621-06
Ul VI
SHOP DRAWING SUBMITTAL REVIEW
Q CONFORMS TO DESIGN CONCEPT
o This review is for general conformance with plans and specifications only. n CONFORMS TO DESIGN CONCEPT WITH
o
Approvals are subject to contractor's performance within the confines of the REVISIONS NOTED
contract documents. Review of dimensions will not serve to relieve the contractor
0 NON-CONFORMING-REVISE&RESUBMIT
c of contractual responsibility for any deviation from the contract requirements. THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCE
n 3 WITH DESIGN CONCEPT ONLY AND DOES NOT RELIEVE THE
0 91 _X Approved as noted Note,markings FABRICATORNENDOR OF RESPONSIBILITY FOR CONFORMANCE WITH DESIGN
XDRAWINGS,SPECIFICATIONS,AND APPLICABLE CODES,ALL OF WHICH HAVE
"V ir o cPRIORITY OVER THIS SHOP DRAWING.
—Field measurements or templates --Not approved.-revise and By Alexia Date 3/3/17
P required prior to fabrication resubmit M ! L B R A
-4 MIME 0
VISTA STRUCTURAL ENGINEERING,LLC N D T ARCHITECTS
www.vistastructuraL com
By:Dennis Heier Date: March 2,2017