Loading...
Report (130) e" •• •• •. • • • • •• • • ••• •••• • • • • • •• • Installation Ordrtng Intorniltion • • Reliable's Model G XLO sprinkler must be installed according Specify: to NFPA Standards or the appropriate Factory Mutual Loss Pre- 1. Sprinkler: Model GXLO vention Data Sheets for all area/density methods of design as 2. Orjt taefi/DefActol;:•[Upriglat] [Rendent] well as requirements of the Authority Having Jurisdiction. 3. TI-iaertttj e•Rattng:.['brd`nary, 1:5:F] [Intermediate, Model GXLO sprinklers must be installed with the Reliable 212;P] ['F-4h 2t F] .• ••• • Model H sprinkler wrench. Any other type of wrench may dam- 4. Finishes: (See Finishes Chart) age the sprinkler. 5. Thre ads: -in oh NP•T] [I..%0 77a3/4] [Y2-inch NPT (Up- A leak tight joint should be obtained with a torque of 14 to right Vly�3/4irlSp 3-11/2:4 ijhLobly] 20 lb-ft (19 to 27 N-m) for 3/4-inch NPT and ISO 7-R3A thread 6. Guard: [Nonet f Q-Q'(V1tIt,ht:cl:Lus)] [D-7 (Upright sprinklers. For Y2-inch NPT and ISO 7-R1/2 thread sprinklers the FM)] PD-8•(iFtndtnt4FIl I' o Shield)] [D-9 (Pendent FM recommended installation torque is 8 to 18 lb-ft(11 to 24 N-m). with Shield)] Do not tighten sprinklers over the maximum recommended in- I stallation torque, because it may cause leakage or impairment Model H Sprinkler Use only the Model H of the sprinklers. sprinkler wrench for sprinkler � „ pr removal and installation.Any Maintenance other type of wrench may Model G XLO Sprinklers should be inspected and the sprinkler damage the sprinkler. system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water,ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted(other than facto- ry applied)or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation,sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. ------- ir="MIIIJ: (For 3/4" NPT) r1 MIMI 1.54" 1.87" Do— [59. 1 mm] [47.5mm] PENDENT 129FG01C UPRIGHT The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co.,Inc. A Recycled Inie I r id (800) 431-1588 Sales Offices Paper 1IIdIII (800)848-6051 ��Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.06/15 P/N 9999970022