Report (144) m�.cc — (50\c .* C\Nib` c4 . t 4 DA/K/l�l DSG COMMERCIAL 3 -S TON PACKAGED GAS/ELECTRIC UNITS 14 SEER/UP TO 12.0 EER OFFICE COPY UP TO 81% EFFICIENT COOLING CAPACITY' 35,000— ,'(?♦F(�j'�► J 0 ED HEATING CAPACITY' 46,000—1 :,v • g, JUN 2 6 201$ ..y/ CITY OF TIGAR13 Contents ii G/Via' . \- Nomenclature �� � yE ,, Product Specifications 4 Expanded Cooling Data 13 _` Airflow Data 19 Crankercase Heater 27 Electrical Data 28 r Dimensions 29 0 Wiring Diagrams 33 –for Models with DDC Controls 53 T Accessories 54 g Standard Features Cabinet Features • Patented tubular heat exchanger • Heavy-gauge,galvanized-steel cabinet • High-efficiency scroll compressor with UV resistant powder paintfinish • High and low-pressure switches • Full Perimeter Rail • Copper tube/aluminum fin coils • Sloped drain pan • Contactor with lugs • High-capacity,steel-cased filter drier • 24-volt terminal strip • Convertible airflow orientation • Easy to service • Built-in filter rack with standard 2"filters • Bottom utility entry • Complies with California Low NOx emissions standards s • 3-5 Tons with single speed blower motor units meet the performance specified in Table 6.8.1-1 of ASHRAE Standard 90.1-2013 • AHRI Certified; ETL Listed wrIs or. EA 't YEA 20Y 12 14 pi EAT pARTS ETA EXCHANGER C US tiu� LIMITED ' LITE° �,srEo � tsD9a.ot WO Waft WARRANTY WARRANTY �gxi,:'. Intertek "`�' *Complete warranty details available from your local distributor or manufacturer's representative or at www.daikincomfort.com. SS-DSG3 www.daikinac.com 1/18A Supersedes 1/18 NOMENCLATURE r D S G 060 090 3 V * * * A 1 2 3 4,5,6 7,8,9 10 11 12 713,E 14 15 16 MI, l REVisioN LEUEls' , �� Major&Minor , D Daikin X No Options i " A Non-powered convenience outlet �k ',µ a �� ', :fr. B Powered convenience outlet C Standard Efficiency(6-25 Tons) L ',,'�r� 1-7 „, 1 C Low-ambient kit S Standard Efficiency(3-5 Tons) ; % D Return air smoke detector T High Efficiency(3-5 Tons) �' �y% i r E Supply air smoke detector O ? ;, F Non-powered convenience outlet; Low-ambient kit C Coolingl ' �' G Non-powered convenience outlet; ire• G Gas Heat Return air smoke detector H Heat Pump' " H Non-powered convenience outlet;2A0 Supply air smoke detector J Non-powered convenience outlet; 036 3 Tons 102 8'/Tons 300 25 Tons •� � Return&Supply air smoke detectors 048 4 Tons 120 10 Tons ,,, �. K Non-powered convenience outlet; 060 5 Tons 150 12%tons Low-ambient kit;Supply air smoke detector 072 6 Tons 180 15 Tons L Non-powered convenience outlet; 090 7'h Tons 240 20 Tons Low-ambient kit �� N/ .4 ; Return&Supply air smoke detectors t MINA fi#A 1NS tT W.,..":::%'',"4:"'" M Powered convenience outlet; Gas/Electric A/C H/P Factory-Installed Electric Heat Low-ambient kit 045 45,000 BTU/h XXX No Heat % N Powered convenience outlet; 090 90,000 BTU/h 010 10 kW 030 30 kW \� % R- eturn air smoke detector 115 115,000 BTU/h 015 15 kW 031 30 kWre\ &:,','T % j 0 Powered convenience outlet; 140 140,000 BTU/h 016 15 kW 045 45 kW !i" R- eturn&Supply air smoke detectors 210 210,000 BTU/h 018 18 kW 046 45 kW / P Powered convenience outlet; 350 350,000 BTU/h 020 20 kW 060 60 kW f 1� Supply air smoke detector 400 400,000 BTU/h 025 25 kW ( F Q Powered convenience outlet;Low-ambient G' . See product specifications for heat size(s)available for each capacity. ( kit;Return air smoke detector (\ it :;,.../1 ` kit;Supply R Powered convenience outlet;Low-ambient VoL7AGE , ,,,,✓ \ /•' it pP Y air smoke detector 1 208-230/1/60(DS*&DT*3-5 Tons models only) 4 460/3/60 c• T Powered convenience outlet;Low-ambient 3 208-230/3/60 7 575/3/60 1 kit;Return&Supply air smoke detectors �` U Non-powered convenience outlet; PPLYFAN/DmV£TYPE�SYft�tt ;' � �, ° Low-ambient kit;Return air smoke detector B Belt Drive(3-5 Tons single speed models only) V Two-Speed Belt Drive V Low-ambient kit;Return air smoke detector D Direct Drive(3-5 Tons single speed models only) (6-25 Tons only) W Low-ambient kit;Supply air smoke detector H High Static(3-5 Tons single-speed Belt W High Static(6-25 Tons i �: Y Low-ambient kit;Return&Supply � Drive models only) two-speed Belt Drive air smoke detectors models only) •i Z Return&Supply air smoke detectors A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer B DDC-BACnet protocol DDC-BACnet protocol; r F Ultra Low-Leak Downflow Economizer; Disconnect Switch(non-fused) � �XIfi'vrA11 1 DDC-BACnet protocol V Low-Leak Downflow Economizer X Standard Aluminized Heat Exchanger H Disconnect Switch(non-fused) W Low-Leak Downflow Economizer S Stainless-Steel Heat Exchanger 1 Ultra Low-Leak Downflow Economizer; Disconnect Switch(non-fused) D Hinged Panels Disconnect Switch(non-fused) X No Options K Stainless-Steel Heat Exchanger; M Disconnect Switch(non-fused);DDC-BACnet protocol Hinged Panels B Phase Monitor Note: Not all options available for all products. J Stainless Steel Heat Exchanger;Phase Monitor 'X=No Options in character 13th M Hinged Panel;Phase Monitor L Stainless-Steel Heat Exchanger; Hinged Panels;Phase Monitor 2 www.daikinac.com SS-DSG3 t � FACTORY-INSTALLED OPTIONS • Stainless-Steel Heat Exchanger(Gas only units):A tubular heat exchanger made of 409-type stainless steel is installed in the unit. • Low-Ambient Kit:Allows for cooling operation at lower outdoor temperatures.On the 3-to 6-ton units,cooling operation is extended a from 60°F ambient temperature to 35°F outside air temperature.On 7%:-20 ton units,cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature.For 25 ton units,cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature. • Economizers(Downflow):Based on air conditions,can provide outside air to cool the space. • Electric Heat Kits(heat pump and cooling units only):Available in all voltage options. • Non-powered Convenience Outlet:A 120V,15A,GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. • Powered Convenience Outlet:A 120V,15A,GFCI outlet powered with a transformer built into the unit.When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA(Min.Circuit Ampacity)will increase by 7.2A/6.5A for 208/230V units, increase by 3.3A for 460V units,and by 2.6A for 575V units.The MOP(Max.Overcurrent Protection)device must be sized accordingly. • Disconnect Switch(non-fused;3-phase units only):A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit.Please note that for air conditioning and heat pump models,the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch(non-fused)when it is ordered. Please note that for models with a powered con- venience outlet option and a disconnect switch(non-fused)option,the power to the powered convenience outlet will be shut off when the disconnect switch(non-fused)is in the off position. • Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. • Hinged Access Panels:Allows access to unit's major components. Combined with latches for easy access to control box,compressor, filters and blower motor.Available on all units. • Two-speed indoor fan blower models are available on 6,7%1,8%1,10,12%,15,20&25 ton units.Section 6.4.3.10.b of ASHRAE Standard 90.1-2010 and Section 6.5.3.2.1.a of ASHRAE Standard 90.1-2013 require a minimum of two fan speeds.Section 140.4(m)1 of California Energy Commission Title 24 2013 contains a similar provision.When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling,the fan operates at low speed,which is 66%of full speed.When the units operate on a call for the second stage of cooling,the fan operates at full speed. In heating operation,the fan operates at full speed.During ventilation operation,the fan operates at low speed. • Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. • Hinged Access Panels:Allows access to unit's major components. Combined with latches for easy access to control box,compressor, filters and blower motor.Available on all models. • Phase Monitor:Phase monitor(3 phase only),available for 3-25 ton DS,DC and DT series models.Phase monitor shall provide protection for motors and compressors against problems caused by phase loss,phase reversal and phase unbalance.Phase monitor is equipped with an LED that provides an ON or FAULT indicator. • DDC Controller:DDC communicating controller,available for 3-25 ton DS,DC and DT series models with on-board BACnet° communication interface. SS-DSG3 www.daikinac.com 3 PRODUCT SPECIFICATIONS-3 TONS r DSG036 DSG036DSG036 DSG036 0451D***A* 0453D***A* I 0453B***A* I 0454B***A* COOLING CAPACITY Total BTU/h 36,000 36,000 35,000 35,000 Sensible BTU/h 26,640 26,640 25,600 25,600 SEER/EER 14/12 14/12 14/12 14/12 • Decibels 78 78 78 78 AHRI Reference#s 9967131 9967134 9952114 9952120 HEATING CAPACITY High Input/Output BTU/h 46/36.8 46/36.8 46/36.8 46/36.8 Low Input/Output BTU/h --- --- --- --- Thermal Efficiency(T.E.) --- 80 80 80 Annual Fuel Utilization Efficiency(AFUE) 81 --- --- --- Temperature Rise Range(°F)Hi/Low 25-55 25-55 25-55 25-55 No.of Burners 2 2 2 2 EVAPORATOR MOTOR/COIL Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal CFM 1,250 1,250 1,200 1,200 Motor Speed Tap(Cooling) Low Speed Low Speed -- -- Indoor Motor FLA(Cooling) 2.46 2.46 3.4 1.7 Horsepower-RPM 1/3-910 1/3-910 1.0-1725 1.0-1725 Piston Size(Cooling) 0.070 0.070 0.070 0.070 Filter Size(") (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) %" %" %" %. R-410A Refrigerant Charge Cir#1(oz.) 105 105 105 105 Evaporator Coil Face Area(ft2) 7.0 7.0 7.0 7.0 Rows Deep/Fins per Inch 4/16 4/16 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(D x W) --- ---- 1(11"x10") 1(11"x10") Motor Sheave --- --- 1VL34 X% 1VL34 X Blower Sheave/Belt ---- --- AK61 x 1/AX51 AK61 x 1/AX51 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 1 1 Horsepower-RPM '/.-1,075 ''/-1,075 '/.-1,075 %-1,050 Fan Diameter/#Fan Blades 22/4 22/4 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 3,800 3,800 Face Area(ft2) 17.1 17.1 17.1 17.1 Rows Deep/Fins per Inch 1/24 1/24 1/24 1/24 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 16.7/79.0 10.4/73.0 10.4/73.0 5.8/38.0 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 Indoor Blower HP/FLA 1/3/2.46 1/3/2.46 1/3.4 1/1.7 Max.External Static 0.5" 0.5" 1.0" 1.0" Outdoor Fan HP/FLA '/./1.4 '/./1.4 ''A/1.4 '/./0.7 Min.Circuit Ampacity' 24.7/24.7 16.9/16.9 17.9/17.9 9.6 Max.Overcurrent Protection(amps)2 40/40 25/25 25/25 15 Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 Low-Voltage Conduit Hole /" %," 'A" j," OPERATING WEIGHT(LBS) 565 565 565 565 SHIP WEIGHT(LBS) 590 590 590 590 1 Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. 4 www.daikinac.com SS-DSG3 PRODUCT SPECIFICATIONS—3 TONS(CONT.) DSG036 I DSG036 07038***A* 0704B***A* COOLING CAPACITY • Total BTU/h 35,000 35,000 Sensible BTU/h 25,600 25,600 SEER/EER 14/12 14/12 • Decibels 78 78 AHRI Reference#s 9952114 9952120 HEATING CAPACITY High Input/Output BTU/h 69/55 69/55 Low Input/Output BTU/h 51/41 51/41 Thermal Efficiency(TE.) 80 80 Annual Fuel Utilization Efficiency(AFUE) --- _ Temperature Rise Range("F)Hi/Low 25-55/15-45 25-55/15-45 No.of Burners 3 3 EVAPORATOR MOTOR/COIL Motor Type Belt Drive Belt Drive Indoor Nominal CFM 1,200 1,200 Motor Speed Tap(Cooling) Indoor Motor FLA(Cooling) 3.4 1.7 Horsepower-RPM 1.0-1725 1.0-1,725 Piston Size(Cooling) 0.070 0.070 Filter Size(") (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) / %ii R-410A Refrigerant Charge Cir#1(oz.) 105 105 Evaporator Coil Face Area(ft2) 7.0 7.0 Rows Deep/Fins per Inch 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(DxW) 1(11"x10") 1(11"x10") Motor Sheave 1VL34 x% 1VL34 x s% Blower Sheave/Belt AK61 x 1/AX51 AK61 x 1/AX51 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 Horsepower-RPM '4-1,075 /.-1,050 Fan Diameter/#Fan Blades 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 Face Area(ft2) 17.1 17.1 Rows Deep/Fins per Inch 1/24 1/24 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 10.4/73.0 5.8/38.0 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-3-60 460-3-60 Indoor Blower HP/FLA 1/3.4 1/1.7 Max.External Static 1.0" 1.0" Outdoor Fan HP/FLA '/./1.4 ''4/0.7 Min.CircuitAmpacity' 17.9 10 Max.Overcurrent Protection(amps)2 25 15 Power Supply Conduit Hole 1.125 1.125 Low-Voltage Conduit Hole '4" A" OPERATING WEIGHT(LBS) 570 570 SHIP WEIGHT(LBS) 595 595 Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. SS-DSG3 www.daikinac.com 5 PRODUCTSPECIFIC4TIONS-3 TONS(CONT.) , . DSG036DSG036 DSG036 DSG036 DSG036 0901D***A* I 0903D***A* I 0903E***A* I 0904B***A* 0907E***A* COOLING CAPACITY • Total BTU/h 36,000 36,000 35,000 35,000 35,000 Sensible BTU/h 26,640 26,640 25,600 25,600 25,600 SEER/EER 14/12 14/12 14/12 14/12 14/12 - Decibels 78 78 78 78 78 AHRI Reference Us . 9967131 9967134 9952114 9952120 9952126 HEATING CAPACITY High Input/Output BTU/h 92/75 92/74 92/74 92/74 92/74 Low Input/Output BTU/h 69/56 69/55 69/55 69/55 69/55 Thermal Efficiency(T E.) --- 80 80 80 80 Annual Fuel Utilization Efficiency(AFUE) 81 --- --- --- Temperature Rise Range(°F)Hi/Low 30-60/20-50 40-70/30-60 40-70/30-60 25-55 25-55 No.of Burners 4 4 4 4 4 EVAPORATOR MOTOR/COIL Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal CFM 1,250 1,250 1,200 1,200 1,200 Motor Speed Tap(Cooling) LOW LOW --- --- --- Indoor Motor FLA(Cooling) 2.46 2,46 3.4 1.7 2.3 Horsepower-RPM %-910 '/-910 1.0-1725 1.0-1,725 1.5-1,725 Piston Size(Cooling) 0.070 0.070 0.070 0.070 0.070 Filter Size(") (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) %" %" %" %" %" R-410A Refrigerant Charge Cir 111(oz.) 105 105 105 105 105 Evaporator Coil Face Area(ft2) 7.0 7.0 7.0 7.0 7.0 Rows Deep/Fins per Inch 4/16 4/16 4/16 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(D x W) ---- ---- 1(11"x 10") 1(11"x 10") 1(11"x 10") Motor Sheave ---- ---- 1VL34 x% 1VL34 x' 1VL34 x Blower Sheave/Belt ---- ---- AK61 x 1/AX51 AK61 x 1/AX51 AK61 x 1/AX51 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 1 1 1 Horsepower-RPM Y.-1,075 /.-1,075 '/.-1,075 '/.-1,050 ''4-1,050 Fan Diameter/#Fan Blades 22/4 22/4 22/4 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800 Face Area(ft2) 17.1 17.1 17.1 17.1 17.1 Rows Deep/Fins per Inch 1/24 1/24 1/24 1/24 1/24 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 16.7/79.0 10.4/73.0 10.4/73.0 5.8/38.0 3.8/36.5 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60 Indoor Blower HP/FLA 1/3/2.46 1/3/2.46 1/3.4 1/1.7 1.5/2.3 Max.External Static 0.5" 0.5" 1.0" 1.0" 1.0" Outdoor Fan HP/FLA '/./1.4 ''4/1.4 '/./1.4 ''4/0.7 /./0.55 Min.Circuit Ampacity' 24.7/24.7 16.9/16.9 16.9/16.9 9.6 7.6 Max.Overcurrent Protection(amps)2 40/40 25/25 25/25 15 15 Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 1.125 Low-Voltage Conduit Hole %" %z" %1" 34" 34" OPERATING WEIGHT(LBS) 575 575 575 575 575 SHIP WEIGHT(LBS) 600 600 600 600 600 1 Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. 6 www.daikinac.com SS-DSG3 PRODUCT SPECIFICATIONS—4 TONS DSG048 DSG048 07036***A* 07048***A* COOLING CAPACITY Total BTU/h 47,000 47,000 Sensible BTU/h 35,000 35,000 SEER/EER 14/11.8 14/11.8 • Decibels 78 78 AHRI Reference#s 9952115 9952121 HEATING CAPACITY High Input/Output BTU/h 69/55 69/55 Low Input/Output BTU/h 51/41 51/41 Thermal Efficiency(TE.) 80 80 Annual Fuel Utilization Efficiency(AFUE) Temperature Rise Range(CF)Hi/Low 20-50/10-40 20-50/10-40 No.of Burners 3 3 EVAPORATOR MOTOR/COIL Motor Type Belt Drive Belt Drive Indoor Nominal CFM 1,600 1,600 Motor Speed Tap(Cooling) -- -- Indoor Motor FLA,(Cooling) 3.4 1.7 Horsepower-RPM 1.0/1,725 1.0/1,725 Piston Size(Cooling) 0.074 0.074 Filter Size(") (4)14 x 20 x 2 (4)14"x 20"x 2" Drain Size(NPT) R-410A Refrigerant Charge Cir#1(oz.) 111 111 Evaporator Coil Face Area(ft2) 7.8 7.8 Rows Deep/Fins per Inch 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(D x W) (1)11x10 (1)11x10 Motor Sheave VL40 X% VL40 X% Blower Sheave/Belt AK66 X 1/AX52 AK66 X 1/AX52 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 Horsepower-RPM '/.-1,075 N-1050 Fan Diameter/#Fan Blades 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 Face Area(ft2) 12.5 12.5 Rows Deep/Fins per Inch 2/27 2/27 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 13.1/83.1 6.1/41 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-3-60 460-3-60 Indoor Blower HP/FLA 1.0/3.4 1.0/1.7 Max.External Static 1.0" 1.0" Outdoor Fan HP/FLA N/1.4 N/0.7 Min.CircuitAmpacity' 21.2 10.0 Max.Overcurrent Protection(amps)2 30 15 Power Supply Conduit Hole 1.125 1.125 Low-Voltage Conduit Hole '/" %" OPERATING WEIGHT(LBS) 605 605 SHIP WEIGHT(LBS) 630 630 ' Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. SS-DSG3 www.daikinac.com 7 PRODUCT SPECIFICATIONS-4 TONS(CONT.) 1 DSG048 1 DSG048 1 DSG048 1 DSG048 0901D***A* 0903D***A* 0903B***A* 0904B***A* COOLING CAPACITY Total BTU/h 48,000 48,000 47,000 47,000 Sensible BTU/h 35,520 35,520 35,000 35,000 SEER/EER 14/12 14/12 14/11.8 14/11.8 Decibels 78 78 78 78 AH RI Reference#s 9967132 9967135 9952115 9952121 HEATING CAPACITY High Input/Output BTU/h 92/75 92/74 92/74 92/74 Low Input/Output BTU/h 69/56 69/55 69/55 69/55 Thermal Efficiency(T E.) --- 80 80 80 Annual Fuel Utilization Efficiency(AFUE) 81 --- --- --- Temperature Rise Range("F)Hi/Low _25-50/15-45 30-60/15-45 30-60/15-45 30-60/15-45 No.of Burners 4 4 4 4 EVAPORATOR MOTOR/COIL Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal CFM 1,600 1,600 1,600 1,600 Motor Speed Tap(Cooling) LOW LOW --- -- Indoor Motor FLA(Cooling) 2.80 2.80 3.4 1.7 Horsepower-RPM Y.-1,025 %-1,025 1.0/1,725 1.0/1,725 Piston Size(Cooling) 0.076 0.076 0.074 0.074 Filter Size(Qty) (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14 x 20 x 2 (4)14"x 20"x 2" Drain Size(NPT) %. %" ''/<" ''/." R-410A Refrigerant Charge Cir#1(oz.) 110 110 111 111 Evaporator Coil Face Area(ft2) 7.8 7.8 7.8 7.8 Rows Deep/Fins per Inch 4/16 4/16 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(D x W) ---- ---- (1)11x10 (1)11x10 Motor Sheave ---- ---- VL40 X s% VL40 X% Blower Sheave/Belt --- ---- AK66 X 1/AX52 AK66 X 1/AX52 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 1 1 Horsepower-RPM '/<-1,075 'A-1,075 'A-1,075 /.-1050 Fan Diameter/#Fan Blades 22/4 22/4 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 3,800 3,800 Face Area(ft2) 12.5 12.5 12.5 12.5 Rows Deep/Fins per Inch 2/27 2/27 2/27 2/27 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 19.9/109 13.1/83.1 13.1/83.1 6.1/41 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 '460-3-60 Indoor Blower HP/FLA %/2.8 %/2.8 1.0/3.4 1.0/1.7 Max.External Static 0.5" 0.5" 1.0" 1.0" Outdoor Fan HP/FLA 1.40 1.40 1.40 0.70 Min.Circuit Ampacity' 29/29 20.6/20.6 21.2/21.2 10 Max.Overcurrent Protection(amps)2 45/45 30/30 30/30 15 Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 Low-Voltage Conduit Hole '/" '/" %x" 'A" OPERATING WEIGHT(LBS) 610 610 610 610 SHIP WEIGHT(LBS) 635 635 635 635 1 Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. 8 www.daikinac.com SS-DSG3 PRODUCTSPECIFICATIONS-4 TONS(CONT.) } DSG048 I DSG048 I DSG048 I DSG048 I DSG048 1151D***A* 1153D***A* 11538***A* 11548***A* 11578***A* COOLING CAPACITY Total BTU/h 48,000 48,000 47,000 47,000 47,000 Sensible BTU/h 35,520 35,520 35,000 35,000 35,000 SEER/EER 14/12 14/12 14/11.8 14/11.8 14/11.8 Decibels 78 78 78 78 78 AHRI Reference#s 9967132 9967135 9952115 9952121 9952127 HEATING CAPACITY High Input/Output BTU/h 115/93 115/92 115/92 115/92 115/92 Low Input/Output BTU/h 86/70 89/69 89/69 89/69 89/69 Thermal Efficiency(T E.) --- 80 80 80 80 Annual Fuel Utilization Efficiency(AFUE) 81 --- --- --- --- Temperature Rise Range("F)Hi/Low 40-70/25-55 40-70/25-55 40-70/25-55 40-70/25-55 40-70/25-55 No.of Burners 5 5 5 5 5 EVAPORATOR MOTOR/COIL Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal CFM 1,600 1,600 1,500 1,600 1,600 Motor Speed Tap(Cooling) LOW LOW -- -- -- Indoor Motor FLA(Cooling) 2.80 2.80 3.4 1.7 2.3 Horsepower-RPM '/.-1,025 V.-1,025 1.0/1,725 1.0/1,725 1.5/1,725 Piston Size(Cooling) 0.076 0.076 0.074 0.074 0.074 Filter Size(Qty) (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) V." R-410A Refrigerant Charge Cir#1(oz.) 110 110 111 111 111 Evaporator Coil Face Area(f2) 7.8 7.8 7.8 7.8 7.8 Rows Deep/Fins per Inch 4/16 4/16 4/16 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(D x W) ---- ---- (1)11x10 (1)11x10 (1)11x10 Motor Sheave ---- ---- VL40 XV. VL40 XV. VL40 X V. Blower Sheave/Belt ---- AK66 X 1/AX52 AK66 X 1/A0(52 AK66 X 1/AX52 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 1 1 1 Horsepower-RPM 3/4-1,075 ''A-1,075 '/.-1,075 '/.-1050 'A-1050 Fan Diameter/#Fan Blades 22/4 22/4 22/4 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800 Face Area(ft2) 12.5 12.5 12.5 12.5 12.5 Rows Deep/Fins per Inch 2/27 2/27 2/27 2/27 2/27 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 19.9/109 13.1/83.1 13.1/83.1 6.1/41.0 4.4/33.0 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60 Indoor Blower HP/FLA V../2.8 3/4/2.8 1.0/3.4 1.0/1.7 1.5/2.3 Max.External Static 0.5" 0.5" 1.0" 1.0" 1.0" Outdoor Fan HP/FLA 1.40 1.40 1.40 0.70 0.55 Min.CircuitAmpacity' 29/29 20.6/20.6 21.2/21.2 10 8.3 Max.Overcurrent Protection(amps)2 45/45 30/30 30/30 15 15 Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 1.125 Low-Voltage Conduit Hole %1" %" %:" V." %z" OPERATING WEIGHT(LBS) 615 615 615 615 615 SHIP WEIGHT(LBS) 640 640 640 640 640 ' Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. SS-DSG3 www.daikinac.com 9 PRODUCT SPECIFICATIONS—S TONS i DSG060 1 DSG060 1 DSG060 1 DSG060 0901D***A* 0903D***A* 0903B***A* 0904B***A* COOLING CAPACITY Total BTU/h 58,000 58,000 58,000 58,000 Sensible BTU/h 42,340 42,340 42,800 42,800 SEER/EER 14/11.6 14/11.6 14/11.6 14/11.6 Decibels 78 78 78 78 AHRI Reference#s 9967133 9967136 9952116 9952122 HEATING CAPACITY High Input/Output BTU/h 92/75 92/74 92/74 92/74 Low Input/Output BTU/h 69/56 69/55 69/55 69/55 Thermal Efficiency(TE.) 80 80 80 Annual Fuel Utilization Efficiency(AFUE) 81 --- --- --- Temperature Rise Range(CF)Hi/Low 25-55/20-50 20-50/15-45 20-50/15-45 20-50/15-45 No.of Burners 4 4 4 4 EVAPORATOR MOTOR/COIL Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal CFM 1,800 1,800 1,800 1,800 Motor Speed Tap(Cooling) T3 T3 ---- Indoor Motor FLA(Cooling) 6.90 6.90 3.2 1.5 Horsepower-RPM 1-1,050 1-1,050 1-1760 1-1760 Piston Size(Cooling) 0.086 0.086 0.086 0.086 Filter Size(Qty) (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) '/." y" %" R-410A Refrigerant Charge Cir#1(oz.) 100 100 100 100 Evaporator Coil Face Area(ft2) 7.8 7.8 7.8 7.8 Rows Deep/Fins per Inch 4/16 4/16 4/16 4/16 BELT DRIVE EVAP FAN DATA #of Wheels(D x W) ---- ---- 1(11"x10") 1(11"x10") Motor Sheave ---- ---- VL40 x% VL40 x Blower Sheave/Belt --- --- AK61 x 1/AX52 AK61 x 1/AX52 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 1 1 Horsepower-RPM '/.-1,075 '/.-1,075 ''4-1,075 /.-1,075 Fan Diameter/#Fan Blades 22/4 22/4 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 3,800 3,800 Face Area(ft2) 13 13 13 13 Rows Deep/Fins per Inch 2/27 2/27 2/27 2/27 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single CompressorRLA/LRA 26.4/134.0 16.0/110.0 16.0/110.0 7.8/52 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 Indoor Blower HP/FLA 1.0/6.9 1.0/6.9 1.0/3.2 1.0/1.5 Max.External Static 0.9" 0.9" 1.0" 1.0" Outdoor FanHP/FLA ''4/1.40 '/./1.40 '4/1.40 ''A/0.7 Min.CircuitAmpacity' 41.3/41.3 28.3/28.3 24.6/24.6 11.9 Max.Overcurrent Protection(amps)2 60/60 40/40 40/40 15 Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 Low-Voltage Conduit Hole '/" 'A" 'A" %2" OPERATING WEIGHT(LBS) 610 610 610 610 SHIP WEIGHT(LBS) 635 635 635 635 'Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. 10 www.daikinac.com SS-DSG3 PRODUCT SPECIFICATIONS—S TONS(CONT.) DSG060 DSGO60 11536***A* I 1154B***A* COOLING CAPACITY " Total BTU/h 58,000 58,000 Sensible BTU/h 43,200 43,200 SEER/EER 14/11.6 14/11.6 Decibels 78 78 AHRI Reference#s 9952116 9952122 HEATING CAPACITY High Input/Output BTU/h 115/92 115/92 Low Input/Output BTU/h 86/69 86/69 Thermal Efficiency(T.E.) 80 80 Annual Fuel Utilization Efficiency(AFUE) ---- _--- Temperature Rise Range("F)H i/Low 35-65/25-55 35-65/25-55 No.of Burners 5 5 EVAPORATOR MOTOR/COIL Motor Type Belt Drive Belt Drive Indoor Nominal CFM 1,800 1,800 Motor Speed Tap(Cooling) ---- _-- Indoor Motor FLA(Cooling) 3.2-3.0 1.5 Horsepower-RPM 1.0-1760 1.0-1760 Piston Size(Cooling) 0.086 0.086 Filter Size(") (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) 3. R-410A Refrigerant Charge Cir#1(oz.) 100 100 Evaporator Coil Face Area(ft2) 7.8 7.8 Rows Deep/Fins per Inch 4/16 4/16 _ BELT DRIVE EVAP FAN DATA #of Wheels(D x W) 1(11"x10") 1(11"x10") Motor Sheave VL40 x% VL40 x Y. Blower Sheave/Belt AK61 X 1/AX52 AK61 X 1/AX52 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 Horsepower-RPM X-1,075 /.-1,075 Fan Diameter/#Fan Blades 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 Face Area(ftZ) 13 13 Rows Deep/Fins per Inch 2/27 2/27 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 16.0/110.0 7.8/52.0 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-3-60 460-3-60 Indoor Blower HP/FLA 1.0/3.2 1.0/1.5 Max.External Static 1.0" 1.0" Outdoor Fan HP/FLA '/./1.40 /./0,7 Min.Circuit Ampacity1 24.6 12 • Max.Overcurrent Protection(amps? 40 15 Power Supply Conduit Hole 1.125" 1.125" Low-Voltage Conduit Hole '/ A OPERATING WEIGHT(LBS) 619 619 SHIP WEIGHT(LBS) 644 644 1 Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. SS-DSG3 www.daikinac.com 11 PRODUCT SPECIFICATIONS-5 TONS(CONT.) f DSG060 I DSG060 I DSG060 I DSG060 I DSG060 1401D***A* 1403D***A* 1403B***A* 1404B***A* 1407B***A* COOLING CAPACITY ' Total BTU/h 58,000 58,000 58,000 58,000 58,000 Sensible BTU/h 42,340 42,340 43,200 43,200 42,500 SEER/EER 14/11.6 14/11.6 14/11.6 14/11.6 14/11.6 Decibels 78 78 78 78 78 AHRI Reference#s 9967133 9967136 9952116 9952122 9952128 HEATING CAPACITY High Input/Output BTU/h 138/112 138/110 138/110 138/110 138/110 Low Input/Output BTU/h 104/84 103/83 103/83 103/83 103/83 Thermal Efficiency(TE.) --- 80 80 80 80 Annual Fuel Utilization Efficiency(AFUE) 81 --- --- --- --- Temperature Rise Range("F)Hi/Low 35-65/25-55 35-65/25-55 35-65/25-55 35-65/25-55 35-65/25-55 No.of Burners 6 6 6 6 6 EVAPORATOR MOTOR/COIL Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal CFM 1,800 1,800 1,800 1,800 1,800 Motor Speed Tap(Cooling) T3 T3 ---- ---- Indoor Motor FLA(Cooling) 6.90 6.90 3.2 1.5 1.2 Horsepower-RPM 1.0-1,050 1.0-1,050 1.0-1760 1.0-1760 1.0-1760 Piston Size(Cooling) 0.086 0.086 0.086 0.086 0.086 Filter Size(") (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" (4)14"x 20"x 2" Drain Size(NPT) '/." ''"A" ''"A" R-410A Refrigerant Charge Cir#1(oz.) 100 100 100 100 100 Evaporator Coil Face Area(ftZ) 7.8 7.8 7.8 7.8 7.8 Rows Deep/Fins per Inch 4/16 4/16 4/16 4/16 4/16 BELT DRIVE EVAP FAN DATA #ofWheels(DxW( --- --- 1(11"x10") 1(11"x10") 1(11"x10") Motor Sheave --- VL40 x" VL40 x VL40 x Blower Sheave/Belt ---- --- AK61 X 1/AX52 AK61 X 1/AX52 AK61 X 1/AX52 CONDENSER FAN/COIL Quantity of Condenser Fan Motors 1 1 1 1 1 Horsepower-RPM /.-1,075 'A-1,075 'A-1,075 '/.-1,075 '/.-1,075 Fan Diameter/#Fan Blades 22/4 22/4 22/4 22/4 22/4 Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800 Face Area(ftZ) 13 13 13 13 13 Rows Deep/Fins per Inch 2/27 2/27 2/27 2/27 2/27 COMPRESSOR Quantity/Type/Stage 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single 1/Scroll/Single Compressor RLA/LRA 26.4/134.0 16.0/110.0 16.0/110.0 7.8/52.0 5.7/38.9 ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60 Indoor Blower HP/FLA 1.0/6.9 1.0/6.9 1.0/3.2-3.0 1.0/1.5 1.0/1.2 Max.External Static 0.9" 0.9" 1.0" 1.0" 1.0" • Outdoor Fan HP/FLA '/./1.40 '/./1.40 '/./1.40 '/./0.7 /./0.55 Min.CircuitAmpacity' 41.3/41.3 28.3/28.3 24.6/24.6 11.9 8.9 Max.Overcurrent Protection(amps)2 60/60 40/40 40/40 15 15 Power Supply Conduit Hole 1.125" 1.125" 1.125" 1.125" 1.125" Low-Voltage Conduit Hole '/" '/" '/" 'A" 'A" OPERATING WEIGHT(LEIS) 620 620 620 620 620 SHIP WEIGHT(LBS) 645 645 645 645 645 1 Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. 12 www.daikinac.com SS-DSG3 10 N LP OUTDOOR AMBIENT TEMPERATURE G) 65 I 75 1 85 .1 95 .1 105 I 115 w ENTERING INDOOR WET BULB TEMPERATURE IDB I AIRFLOW 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 MBh 36.7 38.1 41.7 - 35.9 37.2 40.8 - 35.0 36.3 39.8 - 34.2 35.4 38.8 - 32.5 33.7 36.9 - 30.1 31.2 34.2 - S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 - Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 - 1350 KW 2.46 2.51 2.58 - 2.63 2.69 2.77 - 2.79 2.85 2.93 - 2.93 2.99 3.08 - 3.04 3.10 3.20 - 3.14 3.21 3.31 - AMPS 7.3 7.5 7.7 - 7.9 8.0 8.3 - 8.5 8.7 8.9 - 9.0 9.2 9.5 - 9.6 9.8 10.1 - 10.1 10.3 10.6 - HI PR 237 255 270 - 266 287 303 - 303 326 344 - 345 371 392 - 388 418 441 - 429 461 487 - LO PR 112 119 130 - 118 125 137 - 123 130 142 - 129 137 149 - 135 143 157 - 139 148 162 - MBh 35.7 37.0 40.5 - 34.8 36.1 39.6 - 34.0 35.3 38.6 - 33.2 34.4 37.7 - 31.5 32.7 35.8 - 29.2 30.3 33.2 - S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 - Delta T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 - 70 1200 KW 2.44 2.49 2.56 - 2.61 2.67 2.75 - 2.77 2.82 2.91 - 2.90 2.96 3.05 - 3.02 3.08 3.18 - 3.12 3.18 3.28 - AMPS 7.3 7.4 7.7 - 7.8 8.0 8.2 - 8.4 8.6 8.9 - 9.0 9.2 9.4 - 9.5 9.7 10.0 - 10.0 10.2 10.6 - HI PR 235 253 267 - 264 284 300 - 300 323 341 - 342 368 388 - 384 413 437 - 424 457 482 - LO PR 110 118 128 - 117 124 136 - 121 129 141 - 127 136 148 - 134 142 155 - 138 147 160 - MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 35.7 - 30.6 31.7 34.8 - 29.1 30.2 33.0 - 27.0 27.9 30.6 - SIT 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 - Delta T 20 17 13 - 20 17 13 - 20 18 13 - 20 18 13 - 20 17 13 - 19 16 12 - 1 1050 KW 2.39 2.43 2.50 - 2.56 2.61 2.68 - 2.70 2.76 2.84 - 2.84 2.89 2.98 - 2.95 3.01 3.10 - 3.04 3.11 3.20 - ss AMPS 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.2 8.4 8.6 - 8.7 8.9 9.2 - 9.2 9.4 9.7 - 9.7 10.0 10.3 HI PR 228 245 259 - 256 275 291 - 291 313 331 - 331 356 376 - 373 401 423 - 412 443 468 - 5 LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 pn 0 MBh 37.4 38.5 41.6 44.7 36.5 37.6 40.7 43.7 35.6 36.7 39.7 42.6 34.8 35.8 38.7 41.6 33.0 34.0 36.8 39.5 30.6 31.5 34.1 36.6 sir 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43 DeltaT 22 20 16 11 22 20 17 11 22 20 17 12 22 20 17 12 22 20 17 11 20 19 15 11 1350 KW 2.48 2.53 2.60 2.68 2.65 2.71 2.79 2.87 2.81 2.87 196 3.05 2.95 3.01 3.10 3.20 3.07 3.13 3.23 3.33 3.17 3.23 3.34 3.44 AMPS 7.4 7.6 7.8 8.0 7.9 8.1 8.4 8.6 8.6 8.8 9.0 9.3 9.1 9.3 9.6 9.9 9.6 9.9 10.2 10.5 10.2 10.4 10.7 11.1 HI PR 240 258 272 284 269 289 306 319 306 329 348 363 348 375 396 413 392 422 445 465 433 466 492 513 LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 169 141 150 164 174 MBh 36.3 37.4 40.4 43.4 35.4 36.5 39.5 42.4 34.6 35.6 38.5 41.4 33.7 34.7 37.6 40.4 32.1 33.0 35.7 38.3 29.7 30.6 33.1 35.5 S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41 DeltaT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 1 k 75 1200 KW 2.46 2.51 2.58 2.66 2.63 2.69 2.77 2.85 2.79 2.85 2.93 3.02 2.93 2.99 3.08 3.18 3.04 3.11 3.20 3.30 3.14 3.21 3.31 3.42 AMPS 7.3 7.5 7.7 8.0 7.9 8.1 8.3 8.6 8.5 8.7 8.9 9.3 9.0 9.2 9.5 9.9 9.6 9.8 10.1 10.4 10.1 10.3 10.6 11.0 0 HI PR 237 255 270 281 266 287 303 316 303 326 344 359 345 371 392 409 388 418 441 460 429 461 487 508 p LO PR 112 119 130 138 118 125 137 146 123 130 142 152 129 137 149 159 135 144 157 167 140 148 162 173 MBh 33.5 34.5 37.3 40.0 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.1 32.1 34.7 37.3 29.6 30.5 33.0 35.4 27.4 28.2 30.5 32.8 0 F S/T 0.79 . 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39 1 Zri Delta T 23 21 17 12 23 22 18 12 23 22 18 12 24 22 18 12 23 21 18 12 22 20 16 11 I G) 1050 KW 2.41 2.45 2.52 2.60 2.58 2.63 2.70 2.79 2.73 2.78 2.86 2.95 2.86 2.92 3.01 3.10 2.97 3.03 3.13 3.22 3.07 3.13 3.23 3.33 CD AMPS 7.2 7.3 7.5 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.7 9.0 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2 9.8 10.1 10.4 10.7 15j HI PR 230 248 262 273 258 278 294 306 294 316 334 348 335 360 380 397 376 405 428 446 416 448 473 493 LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 , W IDB=Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)Rating conditions kW=Total system power p w High and low pressures are measured at the liquid and suction service valves. Amps=outdoor unit amps(comp.+fan) 1 OUTDOOR AMBIENT TEMPERATURE 65 75 J 85 I 95 I 105 I 115 ENTERING INDOOR WET BULB TEMPERATURE IDB I AIRFLOW 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 MBh 38.0 38.9 41.5 44.4 37.1 38.0 40.6 43.3 36.3 37.1 39.6 42.3 35.4 36.1 38.6 41.3 33.6 34.3 36.7 39.2 31.1 31.8 34.0 36.3 (� S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.82 0.62 o DeltaT 24 23 20 16 25 24 21 16_ 25 24 21 16 24 24 21 17 23 23 20 16 21 22 19 15 1350 KW 2.50 2.55 2.62 2.70 2.67 2.73 2.81 2.90 2.83 2.89 2.98 3.07 2.97 3.03 3.13 3.23 3.09 3.15 3.25 3.36 3.19 3.26 3.36 3.47 Gl AMPS 7.5 7.6 7.9 8.1 8.0 8.2 8.4 8.7 8.6 8.8 9.1 9.4 9.2 9.4 9.7 10.0 9.7 10.0 10.3 10.6 10.3 10.5 10.8 11.2 HI PR 242 261 275 287 272 292 309 322 309 333 351 366 352 379 400 417 396 426 450 469 437 471 497 519 LO PR 114 121 132 141 120 128 140 149 125 133 145 155 131 140 153 162 138 146 160 170 142 151 165 176 MBh 36.9 37.7 40.3 43.1 36.1 36.9 39.4 42.1 35.2 36.0 38.4 41.1 34.3 35.1 37.5 40.1 32.6 33.3 35.6 38.1 30.2 30.9 33.0 35.3 W S/T 0.90 0.84 0.68 0,51 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.58 1.00 0.96 0.78 0.59 �I DeltaT 25 24 21 17 26 25 21 17 26 25 21 17 26 25 22 17 25 24 21 17 23 23 20 16 80 1200 KW 2.48 2.53 2.60 2.68 2.65 2.71 2.79 2.87 2.81 2.87 2.96 3.05 2.95 3.01 3.10 3.20 3.07 3.13 3.23 3.33 3.17 3.23 3.34 3.44 AMPS 7.4 7.6 7.8 8.0 7.9 8.1 8.4 8.6 8.6 8.8 9.0 9.3 9.1 9.3 9.6 9.9 9.6 9.9 10.2 10.5 10.2 10.4 10.7 11.1 O HI PR 240 258 272 284 269 290 306 319 306 329 348 363 348 375 396 413 392 422 446 465 433 466 492 513 LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 169 141 150 164 174 MBh 34.1 34.8 37.2 39.8 33.3 34.0 36.3 38.8 32.5 33.2 35.5 37.9 31.7 32.4 34.6 37.0 30.1 30.8 32.9 35.1 27.9 28.5 30.5 32.6 S/T 0.86 0.81 0.66 0.49 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.76 0.57 DeltaT 26 25 21 17 26 25 22 17 26 25 22 17 26 25 22 18 26 25 22 17 24 23 20 16 v 1050 KW 2.42 2.47 2.54 2.62 2.59 2.65 2.73 2.81 2.75 2.80 2.89 2.98 2.88 2.94 3.03 3.12 2.99 3.06 3.15 3.25 3.09 3.16 3.26 3.36 AMPS 7.2 7.4 7.6 7.9 7.7 7.9 8.2 8.4 8.4 8.5 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.6 9.9 10.3 9.9 10.1 10.5 10.8 HI PR 233 250 264 276 261 281 297 309 297 319 337 352 338 364 384 401 380 409 432 451 420 452 477 498 LO PR 109 116 127 135 116 123 134 143 120 128 139 149 126 134 146 156 132 141 154 163 137 145 159 169 3 MBh 38.7 39.4 41.3 44.1 37.8 38.5 40.3 43.0 36.9 37.6 39.4 42.0 36.0 36.7 38.4 41.0 34.2 34.9 36.5 38.9 31.7 32.3 33.8 36.1 5/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80 DeltaT 26 26 24 21 26 26 24 21 25 26 24 21 25 25 25 21 23 24 24 21 22 22 23 20 1350 KW 2.51 2.56 2.64 2.72 2.69 2.75 2.83 2.92 2.85 2.91 3.00 3.10 2.99 3.06 3.15 3.25 3.11 3.18 3.28 3.38 3.22 3.29 3.39 3.50 AMPS 7.5 7.7 7.9 8.2 8.1 8.3 8.5 8.8 8.7 8.9 9.2 9.5 9.3 9.5 9.8 10.1 9.8 10.0 10.4 10.7 10.4 10.6 10.9 11.3 HI PR 245 263 278 290 274 295 312 325 312 336 355 370 355 383 404 421 400 430 454 474 442 476 502 524 LO PR 115 122 134 142 121 129 141 150 126 134 147 156 133 141 154 164 139 148 161 172 144 153 167 178 MBh 37.6 38.3 40.1 42.8 36.7 37.4 39.2 41.8 35.8 36.5 38.2 40.8 34.9 35.6 37.3 39.8 33.2 33.8 35.4 37.8 30.8 31.3 32.8 35.0 5/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76 DeltaT 27 27 25 22 27 27 25 22 27 27 25 22 27 27 26 22 25 26 25 22 24 24 24 20 85 1200 KW 2.50 2.55 2.62 2.70 2.67 2.73 2.81 2.90 2.83 2.89 2.98 3.07 2.97 3.03 3.13 3.23 3.09 3.15 3.25 3.36 3.19 3.26 3.36 3.47 AMPS 7.5 7.6 7.9 8.1 8.0 8.2 8.4 8.7 8.6 8.8 9.1 9.4 9.2 9.4 9.7 10.0 9.7 10.0 10.3 10.6 10.3 10.5 10.8 11.2 HI PR 242 261 275 287 272 292 309 322 309 333 351 366 352 379 400 417 396 426 450 469 437 471 497 519 LO PR 114 121 132 141 120 128 140 149 125 133 145 155 131 140 153 162 138 146 160 170 142 151 165 176 MBh 34.7 35.3 37.0 39.5 33.9 34.5 36.2 38.6 33.1 33.7 35.3 37.7 32.3 32.9 34.4 36.7 30.6 31.2 32.7 34.9 28.4 28.9 30.3 32.3 S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73 DeltaT 27 27 26 22 28 27 26 22 28 27 26 22 28 28 26 23 27 27 26 22 25 25 24 21 1050 KW 2.44 2.49 2.56 2.64 2.61 2.67 2.75 2.83 2.77 2.82 2.91 3.00 2.90 2.96 3.05 3.15 3.02 3.08 3.18 3.28 3.12 3.18 3.28 3.39 AMPS 7.3 7.4 7.7 7.9 7.8 8.0 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.6 10.9 HI PR 235 253 267 278 264 284 300 312 300 323 341 355 341 367 388 405 384 413 436 455 424 457 482 503 LO PR 110 117 128 137 117 124 136 144 121 129 141 150 127 136 148 158 133 142 155 165 138 147 160 171 IDB=Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Rating conditions kW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps=outdoor unit amps(comp.+fan) • N w cn OUTDOOR AMBIENT TEMPERATURE G) 65 I 75 I 85 I 95 105 I 115 co ENTERING INDOOR WET BULB TEMPERATURE IDB I AIRFLOW 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 MBh 46.0 47.7 52.3 - 45.0 46.6 51.1 - 43.9 45.5 49.9 - 42.8 44.4 48.6 - 40.7 42.2 46.2 - 37.7 39.1 42.8 S/T 0.77 0.64 0,45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.84 0.70 0.49 - 0.88 0.73 0.51 - 0.88 0.74 0.51 • Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 1800 KW 3.10 3.17 3.26 - 3.33 3.40 3.50 - 3.53 3.60 3.72 - 3.71 3.78 3.90 - 3.86 3.94 4.06 - 3.99 4.07 4.20 AMPS 8.1 8.3 8.6 - 8.7 8.9 9.2 - 9.4 9.7 10.0 - 10.1 10.3 10.6 - 10.7 10.9 11.2 - 11.3 11.5 11.9 HI PR 240 259 273 - 270 290 306 - 307 330 348 - 349 376 397 - 393 423 447 - 434 467 493 LO PR 112 119 130 - 118 126 138 - 123 131 143 - 129 138 150 - 135 144 157 - 140 149 163 MBh 44.7 46.3 50.8 - 43.7 45.3 49.6 - 42.6 44.2 48.4 - 41.6 43.1 47.2 - 39.5 40.9 44.9 36.6 37.9 41.6 S/T 0.73 0.61 0.42 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.84 0.70 0.48 - 0.84 0.70 0.49 Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 - 70 1600 KW 3.08 3.14 3.24 - 3.31 3.37 3.48 - 3.50 3.58 3.69 - 3.68 3.75 3.87 - 3.83 3.91 4.03 - 3.95 4.04 4.17 AMPS 8.1 8.3 8.5 - 8.7 8.9 9.1 - 9.4 9.6 9.9 - 10.0 10.2 10.5 - 10.6 10.8 11.2 - 11.2 11.4 11.8 HI PR 238 256 270 - 267 287 303 - 304 327 345 - 346 372 393 - 389 419 442 - 430 463 488 LO PR 111 118 129 - 117 125 136 - 122 130 142 - 128 136 149 - 134 143 156 - 139 148 161 MBh 41.3 42.8 46.9 - 40.3 41.8 45.8 - 39.3 40.8 44.7 - 38.4 39.8 43.6 - 36.5 37.8 41.4 33.8 35.0 38.4 S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 Delta T 19 17 13 - 19 17 13 - 19 17 13 - 20 17 13 - 19 17 13 - 18 16 12 - 1 1400 KW 3.01 3.07 3.16 - 3.23 3.30 3.39 - 3.42 3.49 3.60 - 3.59 3.67 3.78 - 3.73 3.81 3.93 - 3.86 3.94 4.07 - Q AMPS 7.9 8.0 8.3 - 8.5 8.6 8.9 - 9.1 9.3 9.6 - 9.7 9.9 10.2 - 10.3 10.5 10.9 10.9 11.1 11.5 HI PR 231 248 262 - 259 279 294 - 295 317 335 - 335 361 381 - 377 406 429 417 449 474 OJ D LO PR 108 115 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 135 143 156 p 3 MBh 46.8 48.2 52.2 56.0 45.7 47.1 51.0 54.7 44.6 46.0 49.8 53.4 43.6 44.8 48.5 52.1 41.4 42.6 46.1 49.5 38.3 39.5 42.7 45.8 5/1 0.87 0.78 0.59 0.38 0.91 0.81 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 1.00 0.89 0.67 0.43 1.00 0.90 0.68 0.44 Delta T 21 19 16 11 21 19 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10 1800 KW 3.13 3.19 3.29 3.39 3.36 3.43 3.53 3.64 3.56 3.63 3.75 3.86 3.74 3.82 3.94 4.06 3.89 3.97 4.10 4.23 4.02 4.10 4.24 4.37 AMPS 8.2 8.4 8.6 8.9 8.8 9.0 9.3 9.6 9.5 9.7 10.0 10.4 10.1 10.4 10.7 11.1 10.8 11.0 11.4 11.8 11.4 11.6 12.0 12.4 HI PR 243 261 276 288 272 293 310 323 310 333 352 367 353 380 401 418 397 427 451 470 439 472 498 520 LO PR 113 120 132 140 120 127 139 148 124 132 144 154 131 139 152 162 137 146 159 169 142 151 164 175 MBh 45.5 46.8 50.7 54.4 44.4 45.7 49.5 53.1 43.3 44.6 48.3 51.8 42.3 43.5 47.1 50.6 40.2 41.4 44.8 48.1 37.2 38.3 41.5 44.5 1 01 5/1 0.83 0.75 0.56 0.36 0.86 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.91 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42 Delta T 22 20 16 11 22 20 17 11 22 20 17 12 22 20 17 12 22 20 17 11 20 19 15 11 75 1600 KW 3.11 3.17 3.26 3.36 3.33 3.40 3.50 3.61 3.53 3.60 3.72 3.83 3.71 3.79 3.90 4.03 3.86 3.94 4.06 4.20 3.99 4.07 4.20 4.34 z AMPS 8.1 8.3 8.6 8.9 8.7 8.9 9.2 9.5 9.4 9.7 10.0 10.3 10.1 10.3 10.6 11.0 10.7 10.9 11.3 11.7 11.3 11.5 11.9 12.3 p HI PR 240 259 273 285 270 290 306 320 307 330 349 364 349 376 397 414 393 423 447 466 434 467 493 515 p LO PR 112 119 130 139 118 126 138 147 123 131 143 152 129 138 150 160 136 144 157 168 140 149 163 173 n MBh 42.0 43.2 46.8 50.2 41.0 42.2 45.7 49.0 40.0 41.2 44.6 47.9 39.0 40.2 43.5 46.7 37.1 38.2 41.3 44.4 34.3 35.4 38.3 41.1 . 0 5/1 0.80 0.72 0.54 0.35 0.83 0.75 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.92 0.83 0.63 0.40 Z Delta T 22 20 17 12 22 21 17 12 22 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11 Gl 1400 KW 3.04 3.10 3.19 3.28 3.25 3.32 3.42 3.53 3.45 3.52 3.63 3.74 3.62 3.69 3.81 3.93 3.76 3.84 3.97 4.09 3.89 3.97 4.10 4.23 I AMPS 7.9 8.1 8.4 8.6 8.5 8.7 9.0 9.3 9.2 9.4 9.7 10.0 9.8 10.0 10.3 10.7 10.4 10.6 11.0 11.3 11.0 11.2 11.6 12.0 HI PR 233 251 265 276 262 282 297 310 298 320 338 353 339 365 385 402 381 410 433 452 421 453 479 499 LO PR 109 116 126 135 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 163 136 145 158 168 .I . IDB=Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)Rating conditions kW=Total system power Q� Lri High and low pressures are measured at the liquid and suction service valves. Amps=outdoor unit amps(comp.+fan) • • m OUTDOOR AMBIENT TEMPERATURE 65 I 75 1 85 I 95 I 105 I 115 ENTERING INDOOR WET BULB TEMPERATURE IDB I AIRFLOW 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 MBh 47.7 48.7 52.0 55.6 46.5 47.6 50.8 54.3 45.4 46.4 49.6 53.0 44.3 45.3 48.4 51.7 42.1 43.0 46.0 49.1 39.0 39.9 42.6 45.5 0 S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.63 OO Delta T 23 22 19 16 24 23 20 16 23 23 20 16 23 23 20 16 22 22 20 16 20 20 18 15 I' 1800 KW 3.15 3.22 3.31 3.41 3.38 3.45 3.56 3.67 3.59 3.66 3.78 3.90 3.77 3.85 3.97 4.10 3.92 4.00 4.13 4.26 4.05 4.14 4.27 4.41 Gl AMPS 8.3 8.5 8.7 9.0 8.9 9.1 9.4 9.7 9.6 9.8 10.1 10.5 10.2 10.5 10.8 11.2 10.8 11.1 11.5 11.9 11.5 11.7 12.1 12.5 AU HI PR 245 264 279 291 275 296 313 326 313 337 356 371 356 384 405 422 401 431 456 475 443 477 503 525 LO PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177 MBh 46.3 47.3 50.5 54.0 45.2 46.2 49.3 52.7 44.1 45.1 48.2 51.5 43.0 44.0 47.0 50.2 40.9 41.8 44.6 47.7 37.9 38.7 41.3 44.2 5/1 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.98 0.80 0.59 1.00 0.98 0.80 0.60 �I Delta T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 23 23 20 16 22 22 19 15 80 1600 KW 3.13 3.19 3.29 3.39 3.36 3.43 3.53 3.64 3.56 3.63 3.75 3.87 3.74 3.82 3.94 4.06 3.89 3.97 4.10 4.23 4.02 4.10 4.24 4.38 AMPS 8.2 8.4 8.6 8.9 8.8 9.0 9.3 9.6 9.5 9.7 10.0 10.4 10.1 10.4 10.7 11.1 10.8 11.0 11.4 11.8 11.4 11.6 12.0 12.4 p HI PR 243 261 276 288 272 293 310 323 310 333 352 367 353 380 401 418 397 427 451 471 439 472 498 520 LO PR 113 120 132 140 120 127 139 148 124 132 144 154 131 139 152 162 137 146 159 169 142 151 164 175 MBh 42.7 43.6 46.6 49.8 41.7 42.6 45.5 48.7 40.7 41.6 44.5 47.5 39.7 40.6 43.4 46.4 37.7 38.6 41.2 44.0 35.0 35.7 38.2 40.8 S/T 0.88 0.83 0.67 0.50 0.91 . 0.86 0.70 0.52 0.94 0.88 0.72 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.01 0.95 0.77 0.58 Delta T 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 23 22 19 15 o 1400 KW 3.06 3.12 3.21 3.31 3.28 3.35 3.45 3.56 3.48 3.55 3.66 3.77 3.65 3.72 3.84 3.96 3.79 3.88 4.00 4.13 3.92 4.00 4.13 4.27 AMPS 8.0 8.2 8.4 8.7 8.6 8.8 9.1 9.4 9.3 9.5 9.8 10.1 9.9 10.1 10.4 10.8 10.5 10.7 11.1 11.4 11.1 11.3 11.7 12.1 n HI PR 235 253 268 279 264 284 300 313 301 323 342 356 342 368 389 406 385 414 438 456 425 458 483 504 o LO PR 110 117 128 136 116 123 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170 3 MBh 48.5 49.4 51.8 55.2 47.4 48.3 50.6 53.9 46.2 47.1 49.4 52.7 .45.1 46.0 48.2 51.4 42.8 43.7 45.7 48.8 39.7 40.5 42.4 45.2 S/T 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.93 0.76 1.00 1.00 0.96 0.78 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.82 Delta T 25 24 23 20 24 25 23 20 24 24 23 20 23 23 24 20 22 22 23 20 20 21 22 19 1800 KW 3.18 3.24 3.34 3.44 3.41 3.48 3.59 3.70 3.61 3.69 3.81 3.93 3.80 3.88 4.00 4.13 3.95 4.04 4.16 4.30 4.08 4.17 4.31 4.45 AMPS 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.8 9.7 9.9 10.2 10.6 10.3 10.6 10.9 11.3 10.9 11.2 11.6 12.0 11.6 11.8 12.2 12.6 HI PR 248 267 281 294 278 299 316 329 316 340 359 375 360 387 409 427 405 436 460 480 447 482 508 530 LO PR 116 123 134 143 122 130 142 151 127 135 147 157 133 142 155 165 140 149 162 173 144 154 168 179 MBh 47.1 48.0 50.3 53.6 46.0 46.9 49.1 52.4 44.9 45.8 47.9 51.1 43.8 44.6 46.8 49.9 41.6 42.4 44.4 47.4 38.5 39.3 41.1 43.9 S/T 0.96 0.93 0.84 0.68 0.99 0.96 0.87 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 DeltaT 26 26 24 21 26 26 24 21 26 26 24 21 25 26 25 21 24 24 24 21 22 23 23 20 85 1600 KW 3.15 3.22 3.31 3.41 3.38 3.45 3.56 3.67 3.59 3.66 3.78 3.90 3.77 3.85 3.97 4.10 3.92 4.00 4.13 4.26 4.05 4.14 4.27 4.41 AMPS 8.3 8.5 8.7 9.0 8.9 9.1 9.4 9.7 9.6 9.8 10.1 10.5 10.2 10.5 10.8 11.2 10.8 11.1 11.5 11.9 11.5 11.7 12.1 12.5 HI PR 245 264 279 291 275 296 313 326 313 337 356 371 356 384 405 422 401 431 456 475 443 477 503 525 LO PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177 MBh 43.5 44.3 46.4 49.5 42.4 43.3 45.3 48.3 41.4 42.2 44.2 47.2 40.4 41.2 43.2 46.0 38.4 39.1 41.0 43.7 35.6 36.3 38.0 40.5 S/T 0.92 0.89 0.81 0.65 0.96 0.92 0.83 0.68 0.98 0.95 0.86 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.92 0.74 1.00 1.00 0.92 0.75 Delta T 26 26 25 21 27 26 25 21 27 26 25 22 27 26 25 22 25 26 25 21 23 24 23 20 1400 KW 3.08 3.14 3.24 3.33 3.30 3.37 3.48 3.58 3.50 3.58 3.69 3.80 3.68 3.75 3.87 4.00 3.82 3.91 4.03 4.16 3.95 4.04 4.17 4.30 AMPS 8.1 8.2 8.5 8.8 8.7 8.9 9.1 9.5 9.4 9.6 9.9 10.2 10.0 10.2 10.5 10.9 10.6 10.8 11.1 11.5 11.2 11.4 11.8 12.2 HI PR 238 256 270 282 267 287 303 316 304 327 345 360 346 372 393 410 389 419 442 461 430 462 488 509 N LO PR 111 118 129 137 117 125 136 145 122 130 141 151 128 136 149 158 134 143 156 166 139 148 161 172 IDB=Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Rating conditions kW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps=outdoor unit amps(comp.+fan) • cn OUTDOOR AMBIENT TEMPERATURE G) 65 I 75 I 85 I 95 105 I 115 w ENTERING INDOOR WET BULB TEMPERATURE IDB I AIRFLOW 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 MBh 57.6 59.7 65.4 - 56.3 58.3 63.9 - 54.9 56.9 62.4 - 53.6 55.6 60.9 - 50.9 52.8 57.8 - 47.2 48.9 53.6 - SIT 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.78 0.66 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 - Delta T 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 16 12 - 2050 KW 3.95 4.04 4.17 - 4.26 4.35 4.49 - 4.53 4.63 4.78 - 4.77 4.87 5.04 - 4.97 5.08 5.25 - 5.15 5.26 5.44 - AMPS 10.2 10.4 10.7 - 11.0 11.2 11.6 - 11.9 12.2 12.6 - 12.7 13.0 13.5 - 13.5 13.9 14.3 - 14.3 14.7 15.2 HI PR 257 277 292 - 289 311 328 - 328 353 373 - 374 403 425 - 421 453 478 - 465 500 528 - LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 134 142 155 - MBh 55.9 58.0 63.5 - 54.6 56.6 62.0 - 53.3 55.3 60.6 - 52.0 53.9 59.1 - 49.4 51.2 56.1 - 45.8 47.5 52.0 - S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.81 0.68 0.47 - Delta T 20 17 13 20 18 13 20 18 13 21 18 13 - 20 18 13 19 16 12 70 1800 KW 3.92 4.00 4.13 - 4.22 4.32 4.46 - 4.49 4.59 4.74 - 4.73 4.83 4.99 - 4.93 5.04 5.21 - 5.10 5.22 5.39 - AMPS 10.1 10.3 10.6 - 10.9 11.1 11.5 - 11.8 12.1 12.5 - 12.6 12.9 13.4 - 13.4 13.7 14.2 - 14.2 14.6 15.1 - HI PR 255 274 290 - 286 308 325 - 325 350 370 - 370 399 421 - 417 448 474 - 460 495 523 - LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 132 141 154 - MBh 51.6 53.5 58.6 - 50.4 52.3 57.3 - 49.2 51.0 55.9 - 48.0 49.8 54.5 - 45.6 47.3 51.8 - 42.3 43.8 48.0 - S/T 0.68 0.57 0.39 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.65 0.45 - 0.78 0.65 0.45 - Delta T 21 18 14 - 21 18 14 21 18 14 21 18 14 - 21 18 14 - 20 17 13 - 1550 KW 3.83 3.91 4.03 4.12 4.21 4.35 4.38 4.48 4.62 4.61 4.71 4.87 4.81 4.91 5.08 4.97 5.09 5.26 v AMPS 9.8 10.0 10.4 - 10.6 10.8 11.2 - 11.5 11.8 12.2 - 12.3 12.6 13.0 - 13.1 13.4 13.8 - 13.8 14.2 14.6 - -� HI PR 247 266 281 - 277 298 315 - 315 339 358 - 359 387 408 - 404 435 459 - 447 481 507 7 n LO PR 103 109 119 - 108 115 126 - 113 120 131 - 118 126 137 - 124 132 144 - 128 136 149 0 3 MBh 58.6 60.3 65.3 70.1 57.2 58.9 63.8 68.5 55.9 57.5 62.3 66.8 54.5 56.1 60.7 65.2 51.8 53.3 57.7 61.9 48.0 49.4 53.5 57.4 S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.96 0.85 0.65 0.42 0.96 0.86 0.65 0.42 DeltaT 22 20 17 11 22 21 17 12 22 21 17 12 23 21 17 12 22 20 17 12 21 19 16 11 2050 KW 3.98 4.07 4.20 4.34 4.29 4.39 4.53 4.68 4.57 4.67 4.82 4.98 4.81 4.92 5.08 5.25 5.01 5.13 5.30 5.48 5.19 5.31 5.49 5.68 AMPS 10.3 10.5 10.8 11.2 11.1 11.3 11.7 12.1 12.0 12.3 12.7 13.2 12.8 13.2 13.6 14.1 13.7 14.0 14.5 15.0 14.5 14.8 15.3 15.9 HI PR 260 280 295 308 292 314 332 346 332 357 377 393 378 407 429 448 425 458 483 504 470 506 534 557 LO PR 108 115 125 134 114 121 132 141 119 126 138 147 124 132 145 154 130 139 152 161 135 144 157 167 MBh 56.9 58.6 63.4 68.0 55.6 57.2 61.9 66.5 54.2 55.8 60.5 64.9 52.9 54.5 59.0 63.3 50.3 51.8 56.0 60.1 46.6 47.9 51.9 55.7 S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.59 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40 DeltaT 23 21 18 12 24 22 18 12 24 22 18 12 24 22 18 12 23 22 18 12 22 20 16 11 75 1800 KW 3.95 4.04 4.17 4.30 4.26 4.35 4.49 4.64 4.53 4.63 4.78 4.94 4.77 4.88 5.04 5.21 4.97 5.08 5.25 5.43 5.15 5.26 5.44 5.63 0 AMPS 10.2 10.4 10.7 11.1 11.0 11.2 11.6 12.0 11.9 12.2 12.6 13.1 12.7 13.0 13.5 14.0 13.5 13.9 14.3 14.9 14.3 14.7 15.2 15.8 0 HI PR 257 277 293 305 289 311 328 342 329 354 373 389 374 403 425 443 421 453 478 499 465 501 529 551 Cl LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165 0 MBh 52.5 54.1 58.5 62.8 51.3 52.8 57.2 61.3 50.1 51.5 55.8 59.9 48.8 50.3 54.4 58.4 46.4 47.8 51.7 55.5 43.0 44.3 47.9 51.4 Z S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.73 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.59 0.38 0.89 0.79 0.60 0.39 61 DeltaT 24 22 18 13 24 22 18 13 24 22 18 13 25 23 19 13 24 22 18 13 23 21 17 12 lip 1550 KW 3.86 3.94 4.06 4.20 4.16 4.25 4.38 4.53 4.42 4.51 4.66 4.82 4.65 4.75 4.91 5.07 4.85 4.96 5.12 5.29 5.02 5.13 5.30 5.48 AMPS 9.9 10.1 10.5 10.8 10.7 10.9 11.3 11.7 11.6 11.9 12.3 12.7 12.4 12.7 13.1 13.6 13.2 13.5 13.9 14.5 14.0 14.3 14.8 15.3 HI PR 250 269 284 296 280 302 318 332 319 343 362 378 363 391 412 430 408 439 464 484 451 486 513 535 Ul LO PR 104 110 120 128 110 117 127 135 114 121 132 141 120 127 139 148 125 133 146 155 130 138 151 160 y Tj IDB=Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA(TVA)Rating conditions kW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps=outdoor unit amps(comp.+fan) CO • OUTDOOR AMBIENT TEMPERATURE 65 75 85 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE IDB I AIRFLOW 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 I 59 63 67 71 m0 MBh 59.6 60.9 65.1 69.6 58.3 59.5 63.6 68.0 56.9 58.1 62.1 66.4 55.5 56.7 60.6 64.7 52.7 53.9 57.5 61.5 48.8 49.9 53.3 57.0 S/T 0.92 0.86 0.70 0.53 0.95 0.89 0.73 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.81 0.60 0 DeltaT 25 24 21 16 25 24 21 17 26 24 21 17 25 24 21 17 24 24 21 16 22 22 19 15 2050 KW 4.02 4.10 4.23 4.37 4.33 4.42 4.57 4.72 4.61 4.71 4.86 5.03 4.85 4.96 5.12 5.30 5.06 5.17 5.34 5.53 5.24 5.35 5.53 5.72 AMPS 10.3 10.6 10.9 11.3 11.2 11.4 11.8 12.3 12.1 12,4 12.8 13.3 13.0 13.3 13.7 14.2 13.8 14.1 14.6 15.2 14.6 15.0 15.5 16.1 HI PR 263 283 298 311 295 317 335 349 335 361 381 397 382 411 434 452 429 462 488 509 475 511 539 562 LO PR 109 116 127 135 115 123 134 142 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169 MBh 57.9 59.2 63.2 67.6 56.6 57.8 61.7 66.0 55.2 56.4 60.3 64.4 53.9 55.0 58.8 62.9 51.2 52.3 55.9 59.7 47.4 48.4 51.7 55.3 SIT 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.95 0.77 0.57 Oy Delta T 26 25 22 17 26 25 22 17 26 25 22 18 26 25 22 18 26 25 22 17 24 23 20 16 80 1800 KW 3.98 4.07 4.20 4.34 4.29 4.39 4.53 4.68 4.57 4.67 4.82 4.98 4.81 4.92 5.08 5.25 5.01 5.13 5.30 5.48 5.19 5.31 5.49 5.68 AMPS 10.3 10.5 10.8 11.2 11.1 11.3 11.7 12.1 12.0 12.3 12.7 13.2 12.9 13.2 13.6 14.1 13.7 14.0 14.5 15.0 14.5 14.8 15.3 15.9 HI PR 260 280 295 308 292 314 332 346 332 357 377 393 378 407 430 448 425 458 483 504 470 506 534 557 7-1 LO PR 108 115 125 134 114 121 132 141 119 126 138 147 125 132 145 154 130 139 152 161 135 144 157 167 MBh 53.4 54.6 58.3 62.4 52.2 53.3 57.0 60.9 51.0 52.1 55.6 59.5 49.7 50.8 54.3 58.0 47.2 48.3 51.6 55.1 43.7 44.7 47.8 51.1 S/T 0.85 0.79 0.65 0.48 0.88 0.82 0.67 0.50 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.74 0.55 0.97 0.91 0.74 0.55 not DeltaT 27 26 22 18 27 26 23 18 27 26 23 18 27 26 23 18 27 26 22 18 25 24 21 17 1550 KW 3.89 3.97 4.10 4.23 4.19 4.28 4.42 4.56 4.45 4.55 4.70 4.86 4.69 4.79 4.95 5.12 4.89 5.00 5.16 5.34 5.06 5.17 5.35 5.53 cu AMPS 10.0 10.2 10.5 10.9 10.8 11.0 11.4 11.8 11.7 12.0 12.4 12.8 12.5 12.8 13.2 13.7 13.3 13.6 14.1 14.6 14.1 14.4 14.9 15.5 HI PR 252 271 287 299 283 305 322 335 322 346 366 382 367 395 417 435 412 444 469 489 456 490 518 540 3 LO PR 105 111 122 130 111 118 128 137 115 122 134 142 121 128 140 149 127 135 147 157 131 139 152 162 MBh 60.7 61.9 64.8 69.1 59.3 60.4 63.3 67.5 57.9 59.0 61.8 65.9 56.4 57.5 60.3 64.3 53.6 54.7 57.2 61.1 49.7 50.6 53.0 56.6 S/T 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 0.99 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.96 0.78 DeltaT 26 26 24 21 27 26 25 21 26 26 25 21 25 26 25 22 24 25 25 21 22 23 23 20 2050 KW 4.05 4.14 4.27 4.41 4.37 4.46 4.61 4.76 4.64 4.75 4.90 5.07 4.89 5.00 5.17 5.34 5.10 5.21 5.39 5.57 5.28 5.40 5.58 5.77 AMPS 10.4 10.7 11.0 11.4 11.3 11.5 11.9 12.4 12.2 12.5 13.0 13.4 13.1 13.4 13.9 14.4 13.9 14.3 14.7 15.3 14.8 15.1 15.6 16.2 HI PR 265 285 301 314 298 320 338 353 339 364 385 401 386 415 438 457 434 467 493 514 479 516 545 568 LO PR 110 117 128 136 116 124 135 144 121 129 140 150 127 135 148 157 133 142 155 165 138 146 160 170 MBh 58.9 60.1 62.9 67.1 57.5 58.7 61.4 65.5 56.2 57.3 60.0 64.0 54.8 55.9 58.5 62.4 52.1 53.1 55.6 59.3 48.2 49.2 51.5 54.9 5/1 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75 DeltaT 28 27 26 22 28 28 26 23 28 28 26 23 28 28 26 23 27 27 26 22 25 25 24 21 85 1800 KW 4.02 4.10 4.23 4.37 4.33 4.42 4.57 4.72 4.61 4.71 4.86 5.03 4.85 4.96 5.12 5.30 5.06 5.17 5.34 5.53 5.24 5.35 5.53 5.72 AMPS 10.3 10.6 10.9 11.3 11.2 11.4 11.8 12.3 12.1 12.4 12.8 13.3 13.0 13.3 13.7 14.2 13.8 14.1 14.6 15.2 14.6 15.0 15.5 16.1 HI PR 263 283 298 311 295 317 335 349 335 361 381 397 382 411 434 452 429 462 488 509 475 511 539 562 LO PR 109 116 127 135 115 123 134 142 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169 MBh 54.4 55.4 58.1 61.9 53.1 54.1 56.7 60.5 51.8 52.8 55.4 59.1 50.6 51.6 54.0 57.6 48.1 49.0 51.3 54.7 44.5 45.4 47.5 50.7 S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.94 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 0.98 0.89 0.72 Delta T 29 28 27 23 29 28 27 23 29 29 27 23 29 29 27 23 29 28 27 23 26 26 25 22 1550 KW 3.92 4.00 4.13 4.26 4.22 4.32 4.45 4.60 4.49 4.59 4.74 4.90 4.73 4.83 4.99 5.16 4.93 5.04 5.21 5.38 5.10 5.22 5.39 5.58 rte1) AMPS 10.1 10.3 10.6 11.0 10.9 11.1 11.5 11.9 11.8 12.1 12.5 13.0 12.6 12.9 13.3 13.8 13.4 13.7 14.2 14.7 14.2 14.6 15.0 15.6 o HI PR 255 274 289 302 286 308 325 339 325 350 369 385 370 398 421 439 417 448 473 494 460 495 523 546 LO PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130 142 151 128 136 148 158 132 141 154 164 IDB=Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Rating conditions kW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps=outdoor unit amps(comp.+fan) AIRFLOW DATA-3 TONS STANDARD BELT DRIVE - DOWN SHOT TURNS OPEN ESP ("H20) 0 1 2 3 4 5 CFM I BHP CFM I BHP CFM I BHP CFM I BHP 1 CFM I BHP 1 CFM I BHP 0.1 --- 1279 0.31 1071 0.26 0.2 1291 0.32 1124 0.28 916 0.23 0.3 --- --- --- 1134 0.30 969 0.25 717 0.21 0.4 --- --- --- --- 1213 0.32 977 0.29 770 0.23 0.5 --- --- 1227 0.38 1029 0.30 773 0.26 --- --- 0.6 1283 0.43 1076 0.35 867 0.29 .--- --- --- --- 0.7 1125 0.40 891 0.31 699 0.27 --- --- --- 0.8 949 0.37 696 0.29 --- --- 0.9 687 0.33 --- --- --- 1.0 634 0.30 --- --- HIGH-STATIC BELT DRIVE - DOWN SHOT TURNS OPEN ESP ("H20) 0 1 2 3 4 5 CFM I BHP 1 CFM I BHP CFM I BHP CFM I BHP 1 CFM I BHP CFM I BHP 0.6 --- --- --- --- --- 0.7 --- --- --- --- --- --- --- 1222 0.40 0.8 --- --- --- --- --- --- --- , 1117 0.39 0.9 --- --- --- --- 1221 0.46 1012 0.38 1.0 --- --- --- --- 1246 0.52 1078 0.42 869 0.35 1.1 --- --- --- --- 1126 0.49 935 0.39 725 0.33 1.2 --- --- --- 1268 0.56 1006 0.46 763 0.36 --- 1.3 --- 1335 0.65 1141 0.53 847 0.42 1.4 --- 1212 0.62 1014 0.50 690 0.38 --- 1.5 1314 0.72 1090 0.58 887 0.47 --- 1.6 1187 0.67 922 0.53 750 0.43 --- --- --- ' 1.7 1060 0.63 753 0.49 --- --- --- 1.8 978 0.61 --- --- --- Note: Tables represent dry coil without filter;to compensate for filter,add 0.08"to measured E.S.P.SCFM correction for wet coil=4%. 55-DSG3 www.daikinac.com 19 AIRFLOW DATA-3 TONS(CONT) . b STANDARD BELT DRIVE - HORIZONTAL TURNS OPEN ESP . 0 ("H20) 1 2 3 4 5 CFM I BHP CFM I BHP CFM I BHP 1 CFM I BHP CFM I BHP 1 CFM I BHP 0.1 1190 0.29 0.2 --- --- --- 1249 0.31 1018 0.26 0.3 --- --- --- --- 1260 0.34 1077 0.28 797 0.24 0.4 --- --- 1318 0.35 1085 0.33 856 0.26 --- --- 0.5 --- 1334 0.41 1119 0.33 859 0.30 --- --- --- --- 0.6 1395 0.46 1170 0.38 942 0.31 --- --- --- --- --- 0.7 1223 0.43 968 0.34 760 0.30 --- --- --- --- --- 0.8 1032 0.40 756 0.31 --- --- --- --- --- 0.9 747 0.36 --- --- --- 1.0 688 0.33 --- --- --- --- --- --- --- --- HIGH-STATIC BELT DRIVE - HORIZONTAL TURNS OPEN ESP ("H20) 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- 0.7 --- --- -- --- 0.8 --- --- 1269 0.45 0.9 --- 1150 0.44 1.0 --- 1225 0.48 988 0.40 1.1 --- --- --- 1280 0.55 1063 0.44 824 0.37 1.2 --- 1143 0.52 867 0.40 --- --- 1.3 --- --- 1268 0.59 963 0.48 651 0.36 --- --- 1.4 --- 1332 0.68 1127 0.55 766 0 43 --- --- 1.5 --- 1198 0.64 986 0.52 --- --- --- 1.6 1304 0.74 1013 0.59 833 0.48 --- --- --- 1.7 1165 0.69 828 0.54 --- --- --- 1.8 1075 0.67 --- --- --- --- --- Note:Tables represent dry coil without filter;to compensate for filter,add 0.08"to measured E.S.P.SCFM correction for wet coil=4%. 20 www.daikinac.com SS-DSG3 AIRFLOW DATA-3 TONS(CONT.) STANDARD DIRECT DRIVE - HORIZONTAL STANDARD DIRECT DRIVE- DOWN SHOT CFM STATIC AMPS WATTS RPM I SPEED CFM STATIC I AMPS WATTS RPM SPEED TAP 1280 0.1 1.54 360 755 1270 0.1 1.53 355 760 1215 0.2 1.5 345 800 1205 0.2 1.53 350 810 " 1145 0.3 1.46 335 830 Low 1145 0.3 1.49 340 840 Low 1080 0.4 1.42 325 870 1085 0.4 1.45 330 875 1005 0.5 1.37 310 895 1035 0.5 1.42 320 900 1485 0.1 1.98 460 840 1460 0.1 1.96 450 850 1410 0.2 1.92 440 870 I 1380 I 0.2 1.89 430 885 1335 0.3 1.86 425 900 1275 0.3 1.8 -405 915 1255 0.4 1.8 410 930 Med 1175 0.4 1.73 400 950 Med 1170 0.5 1.75 400 950 1075 0.5 1.68 380 965 1075 0.6 1.68 380 980 1005 0.6 1.63 370 1000 945 0.7 1.6 360 1005 915 0.7 1.59 360 1015 1445 0.3 2.2 505 940 1445 0.3 2.2 500 950 1365 0.4 2.14 490 960 1340 0.4 2.13 480 975 1270 0.5 2.08 470 985 1275 0.5 2.07 465 1000 High 1180 0.6 2.02 460 1000 Med1175 0.6 2.02 455 1020 1050 0.7 1.92 435 1030 1040 0.7 1.92 430 1045 825 0.8 1.78 400 1055 830 0.8 1.78 395 1070 NOTE:Assumes dry coil with filter in place;SCFM correction for wet coil=4% AIRFLOW DATA-4 TONS STANDARD DIRECT DRIVE- HORIZONTAL STANDARD DIRECT DRIVE -DOWN SHOT CFM I STATIC I AMPS I WATTS I RPM I SPEED CFM I STATIC I AMPS I WATTS I RPM I SPEED TAP TAP 1570 0.1 2.09 490 905 1548 0.1 2.03 480 930 1520 0.2 2.06 480 920 1500 0.2 2 470 945 1445 0.3 1.95 460 945 Low 1425 0.3 1.89 450 970 Low 1375 0.4 1.89 440 970 1353 0.4 1.83 430 995 1295 0.5 1.81 425 995 1273 0.5 175 415 1020 1715 0.1 2.39 560 975 1660 0.1 2.31 540 1020 1655 0.2 2.32 545 985 1625 0.2 2.25 530 1035 1580 0.3 2.24 525 1005 1565 0.3 2.19 515 1040 1500 0.4 2.16 505 1020 Med 1485 0.4 2.12 505 1050 Med 1405 0.5 2.09 490 1035 1405 0.5 2.12 500 1055 1305 0.6 2.00 465 1050 1285 0.6 1.98 465 1060 1200 0.7 1.92 440 1065 1200 0.7 1.93 440 1070 1839 0.1 2.77 650 1030 1825 0.1 2.65 620 1045 1770 0.2 2.70 630 1040 1745 0.2 2.55 600 1060 1696 0.3 2.62 610 1050 1670 0.3 2.53 590 1065 1611 0.4 2.53 590 1060 High 1585 0.4 2.46 575 1070 High 1510 0.5 2.44 560 1070 1480 0.5 2.37 550 1080 1418 0.6 2.36 540 1085 1405 0.6 2.31 . 535 1090 Note:Assumes dry coil with filter in place;SCFM correction for wet coil=4% SS-DSG3 www.daikinac.com 21 AIRFLOW DATA-4 TONS(CONT.) STANDARD BELT DRIVE - DOWN SHOT TURNS OPEN ESP 0 1 2 3 4 5 ("H2O) CFM BHP CFM MI=II=VI BHP CFM BHP CFM BHP CFM BHP 0.1 1690 0.42 1553 0.33 0.2 --- 1719 0.47 1548 0.39 1417 0.32 0.3 --- --- --- 1699 0.50 1570 0.44 1406 0.37 1258 0.30 0.4 --- 1742 0.53 1566 0.47 1421 0.41 1258 0.34 1095 0.27 0.5 1770 0.60 1617 0.50 1427 0.44 1278 0.38 1094 0.32 --- 0.6 1664 0.57 1492 0.47 1286 0.41 1127 0.36 --- - 0.7 1558 0.54 1376 0.45 1139 0.38 935 0.32 0.8 1415 0.50 1220 0.41 961 0.35 --- --- --- 0.9 1288 0.47 1054 0.38 --- 1.0 1121 0.43 1.1 953 0.39 HIGH-STATIC BELT DRIVE - DOWN SHOT TURNS OPEN ESP 0 1 2 3 4 5 ("H2O) CFM BHP CFM BHP CFM BHP CFM 0.6 --- --- --- 1688 0.58 1503 0.48 0.7 --- - --- 1716 0.62 1569 0.55 1398 0.46 0.8 --- --- 1613 0.59 1450 0.51 1268 0.43 0.9 --- --- --- 1702 0.67 1510 0.56 1331 0.48 1138 0.40 1.0 --- --- 1589 0.64 1412 0.53 1190 0.45 984 0.37 1.1 --- --- 1751 0.75 1477 0.60 1281 0.50 1052 0.42 --- 1.2 1755 0.85 1605 0.70 1364 0.57 1133 0.46 --- 1.3 1640 0.80 1459 0.66 1224 0.53 983 0.43 --- 1.4 1525 0.76 1313 0.61 1083 0.49 1.5 1410 0.72 1192 0.57 1.6 1276 0.67 1033 0.53 1.7 1137 0.63 --- 1.8 1008 0.59 --- --- --- --- --- --- --- Note: Tables represent dry coil without filter;to compensate for filter,add 0.08"to measured E.S.P.SCFM correction for wet coil=4%. 22 www.daikinac.com SS-DSG3 AIRFLOW DATA-4 TONS(CONT.) STANDARD BELT DRIVE - HORIZONTAL TURNS OPEN ESP ("H2O) CFM I BHP CFM I BHP 1 CFM I BHP I CFM I BHP I CFM I BHP I CFM I BHP 0.1 --- 1726 0.37 0.2 --- --- 1720 0.43 1575 0.36 0.3 1888 0.57 1744 0.48 1562 0.41 1398 0.34 0.4 --- --- 1740 0.54 1579 0.45 1398 0.38 1217 0.31 0.5 --- 1797 0.56 1586 0.51 1420 0.42 1216 0.36 1004 0.28 0.6 1849 0.62 1658 0.53 1429 0.48 1252 0.40 997 0.32 --- 0.7 1731 0.59 1528 0.51 1266 0.45 1039 0.36 --- --- 0.8 1572 0.55 1355 0.47 1068 0.41 --- --- 0.9 1431 0.52 1171 0.43 --- --- --- --- --- 1.0 1245 0.48 987 0.39 --- 1.1 1059 0.44 HIGH-STATIC BELT DRIVE - HORIZONTAL TURNS OPEN ESP ("H2O) 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM WEIBMIIIII 0.6 1669 0.53 0.7 1741 0.61 1553 0.51 0.8 1792 0.66 1610 0.57 1408 0.48 0.9 --- --- 1680 0.63 1479 0.53 1264 0.44 1.0 --- --- --- 1765 0.71 1568 0.59 1323 0.50 1093 0.41 1.1 --- --- --- --- 1640 0.67 1422 0.55 1168 0.46 --- --- 1.2 --- --- 1784 0.78 1515 0.64 1259 0.51 995 0.43 --- --- 1.3 1821 0.89 1621 0.73 1360 0.59 1091 0.47 --- --- --- --- 1.4 1694 0.84 1458 0.68 1202 0.55 --- --- --- --- --- 1.5 1567 0.80 1324 0.63 1042 0.51 --- --- --- --- --- --- 1.6 1417 0.75 1148 0.59 --- --- --- --- --- --- --- 1.7 1262 0.70 --- --- --- --- --- --- --- --- --- --- 1.8 1120 0.66 --- --- --- --- Note: Tables represent dry coil without filter;to compensate for filter,add 0.08"to measured E.S.P.SCFM correction for wet coil=4%. SS-DSG3 www.daikinac.com 23 AIRFLOW DATA-5 TONS STANDARD DIRECT-DRIVE - HORIZONTAL STANDARD DIRECT-DRIVE - DOWN SHOT 1 CFM I STATIC AMPS I WATTS I RPM I TA? D CFM STATIC AMPS WATTS RPM SPEED TAP 1215 0.1 1.4 165 610 1205 0.1 1.47 180 635 1150 0.2 1.46 175 645 1150 0.2 1.54 185 675 • 1085 0.3 1.54 180 690 1065 0.3 1.59 185 730 1010 0.4 1.64 195 725 T1 980 0.4 1.68 195 760 T1 900 0.5 1.74 205 780 860 0.5 1.79 200 810 840 0.6 1.77 215 810 800 0.6 1.82 220 840 1395 0.1 1.86 230 670 1375 0.1 1.94 235 690 1325 0.2 1.95 240 705 1300 0.2 2.01 245 720 1260 0.3 2.01 250 735 1230 0.3 2.05 255 750 1210 0.4 2.10 260 770 1180 0.4 2.15 265 790 1135 0.5 2.16 265 810 T2 1100 0.5 2.22 275 830 T2 1040 0.6 2.28 280 860 1005 0.6 2.33 285 890 970 0.7 2.38 290 885 970 0.7 2.43 295 900 910 0.8 2.46 300 925 915 0.8 2.51 310 940 840 0.9 2.52 310 955 845 0.9 2.57 315 980 1790 0.1 3.24 425 810 1755 0.1 3.34 385 850 1735 0.2 3.37 435 830 1700 0.2 3.47 395 865 1670 0.3 3.45 450 865 1665 0.3 3.56 410 895 1610 0.4 3.55 465 890 1580 0.4 3.68 425 930 1560 0.5 3.60 475 920 T3 1545 0.5 3.72 435 955 T3 1520 0.6 3.70 490 945 1505 0.6 3.80 520 990 1470 0.7 3.80 500 970 1430 0.7 3.93 530 1020 1410 0.8 3.94 510 995 1370 0.8 4.08 535 1040 1345 0.9 3.98 530 1035 1300 0.9 4.12 570 1070 2005 0.1 4.30 575 880 1945 0.1 4.46 600 920 1965 0.2 4.41 590 900 1910 0.2 4.57 620 940 1895 0.3 4.52 610 930 1850 0.3 4.66 635 965 1835 0.4 4.63 620 955 1795 0.4 4.78 655 990 1790 0.5 4.75 635 980 T4 1760 0.5 4.84 670 1020 T4 1745 0.6 4.84 650 1005 1710 0.6 4.96 685 1045 1695 0.7 4.91 660 1030 1640 0.7 5.06 675 1065 1650 0.8 5.03 675 1055 1610 0.8 5.19 690 1090 1600 0.9 5.10 675 1080 1560 0.9 5.22 700 1125 2120 0.1 5.10 690 930 2090 0.1 5.35 720 970 2075 0.2 5.15 710 950 2040 0.2 5.38 740 990 2025 0.3 5.23 720 975 1985 0.3 5.70 755 1025 1975 0.4 5.35 735 995 1935 0.4 5.44 760 1035 1930 0.5 5.46 750 1020 T5 1900 0.5 5.82 780 1050 T5 1875 0.6 5.59 770 1040 1855 0.6 5.73 800 1075 1835 0.7 5.64 780 1065 1810 0.7 5.69 810 1090 1795 0.8 5.73 790 1090 1750 0.8 5.82 825 1120 1735 0.9 5.82 805 1110 1680 0.9 5.94 840 1145 NOTES • Assumes dry coil with filter in place;SCFM correction for wet coil=4% • Five-ton models are shipped from the factory with speed tap set on T4. 24 www.daikinac.com SS-DSG3 AIRFLOW DATA-5 TONS CONT.) STANDARD BELT DRIVE - DOWN SHOT TURNS OPEN ESP ("H2O) CFM I BHP CFM I BHP CFM I BHP CFM I BHP CFM I BHP CFM I BHP 0.1 --- --- --- 2071 0.62 1972 0.54 1816 0.41 1668 0.34 0.2 --- --- 2180 0.70 1977 0.59 1846 0.51 1699 0.39 1533 0.33 0.3 2110 0.79 2066 0.66 1873 0.56 1721 0.47 1572 0.35 1387 0.30 0.4 2024 0.76 1950 0.63 1769 0.53 1596 0.44 1443 0.33 1247 0.27 0.5 1937 0.73 1833 0.60 1643 0.50 1554 0.41 1302 0.30 0.6 1851 0.69 1716 0.56 1523 0.46 1330 0.38 --- 0.7 1764 0.65 1601 0.53 1393 0.42 1186 0.34 0.8 1653 0.61 1477 0.49 1256 0.39 --- 0.9 1534 0.57 1350 0.45 --- --- --- 1.0 1411 0.53 1180 0.40 1.1 1270 0.49 -- HIGH-STATIC BELT DRIVE - DOWN SHOT TURNS OPEN ESP 0 1 2 3 4 5 ("H2O) CFM I BHP 1 CFM I BHP CFM I BHP CFM I BHP CFM I BHP CFM I BHP 0.6 --- --- --- --- --- --- 2227 0.86 2050 0.73 0.7 --- --- --- --- --- 2102 0.82 1932 0.69 0.8 --- --- --- --- --- --- 2274 0.93 1999 0.79 1820 0.67 0.9 2304 1.03 2130 0.88 1859 0.76 1630 0.63 1.0 --- --- --- --- 2162 0.98 2010 0.86 1694 0.72 1487 0.59 1.1 --- --- 2325 1.15 2027 0.94 1820 0.79 1543 0.68 1267 0.55 1.2 2355 1.26 2247 1.11 1902 0.90 1721 0.77 1331 0.63 1.3 2247 1.22 2062 1.05 1768 0.87 1557 0.71 --- --- --- 1.4 2151 1.19 1932 1.01 1579 0.82 1374 0.66 -- 1.5 2004 1.14 1768 0.95 1339 0.74 --- --- 1.6 1895 1.10 1637 0.91 --- 1.7 1727 1.04 1331 0.80 --- 1.8 1391 0.92 --- --- -- Note: Tables represent dry coil without filter;to compensate for filter,add 0.08"to measured E.S.P.SCFM correction for wet coil=4%. SS-DSG3 www.daikinac.com 25 AIRFLOW DATA-5 TONS(CONT.) • STANDARD BELT DRIVE - HORIZONTAL TURNS OPEN ESP ("H20) CFM I BHP 1 CFM I BHP I CFM I BHP CFM I BHP I CFM I BHP CFM I BHP 0.1 --- --- --- 2105 0.49 1940 0.40 0.2 --- 2147 0.57 1975 0.47 1782 0.39 0.3 --- --- --- --- 2178 0.63 2001 0.53 1828 0.43 1613 0.36 0.4 --- --- --- --- 2057 0.60 1855 0.50 1678 0.41 1450 0.33 0.5 2131 0.68 1910 0.57 1691 0.47 1515 0.38 1252 0.29 0.6 2152 0.78 1995 0.64 1771 0.53 1546 0.44 1320 0.34 --- 0.7 2051 0.74 1862 0.61 1620 0.49 1379 0.40 --- --- 0.8 1922 0.70 1718 0.57 1461 0.46 1202 0.37 --- 0.9 1784 0.66 1570 0.53 1296 0.43 1.0 1641 0.62 1371 0.48 1.1 1477 0.58 1200 0.44 1.2 1292 0.53 HIGH-STATIC BELT DRIVE - HORIZONTAL TURNS OPEN ESP 0 1 2 3 4 5 ("H20) CFM I BHP 1 CFM I BHP I CFM I BHP 1 CFM I BHP I CFM I BHP I CFM I BHP 0.6 --- --- 2164 0.89 1985 0.76 0.7 2232 0.99 2047 0.85 1858 0.72 0.8 2104 0.95 1943 0.82 1735 0.70 0.9 --- --- --- --- 2200 1.09 1995 0.92 1819 0.79 1603 0.67 1.0 --- --- 2297 1.22 2086 1.06 1900 0.89 1687 0.75 1410 0.62 1.1 --- 2204 1.19 1995 1.02 1774 0.86 1543 0.71 --- 1.2 2249 1.32 2101 1.15 1875 0.99 1624 0.81 1352 0.66 --- 1.3 2175 1.28 1958 1.11 1740 0.94 1482 0.77 --- --- --- 1.4 2072 1.25 1836 1.06 1587 0.89 1308 0.72 --- --- --- 1.5 1945 1.20 1685 1.00 1402 0.83 --- --- 1.6 1841 1.15 1519 0.94 ___ 1.7 1684 1.09 --- --- --- --- --- --- --- --- 1.8 1541 1.03 --- --- --- --- AIR FLOW PRESSURE DROP OF DOWN FLOW ECONOMIZER AIRFLOW PRESSURE DROP OF DOWNFLOW ECONOMIZER FOR 3 TO 6 TON ROFFTOP UNITS(100%RETURN AIR) SCF, 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 in WG 0.02 0.04 0.05 0.07 0.09 0.12 0.14 0.17 0.21 0.24 0.28 26 www.daikinac.com SS-DSG3 CRANKCASE HEATER HIGH EFFICIENCY MERV 13 AIR FILTER OPTION HIGH EFFICIENCY MERV 13 AIR FILTER OPTION Flanders Pre Pleat. leat M13 ' Air Velocity vs Resistance (Test Size:24"x 24"x 2"High Capacity) 0.50 0.45 3 o` a�2"Deep - = ?'. 0.40 0.35 • 0.30 0) c 0.25 � ate+ 0.15 ' n 0.10 3 0.05 0.00 0 100 200 300 400 500 600 700 Air Velocity(FPM) TONNAGE: FILTER NOMINAL SIZE: PART NUMBER: ORDER QTY: 3 24 x 24 x 2 0160L00203 1 4 14 x 20 x 2 0160L00204 4 5 16 x 20 x 2 0160L00205 4 CRANKCASE HEATER SELECTION TABLE COMPRESSOR VOLTAGE CRANKCASE ZP/ZPS... COMPRESSOR DIAMETER 230V 460V HEATER WATTS 16-31 5.5" 01638000025 01638000315 01638000325 40 39-83 6.58/7.3" 0130L000175 0130L000185 0130L000195 70 103-137 9,14" 0130L000205 0130L000215 0130L000225 90 DC*,DT*&DS*TONNAGE COMPRESSOR VOLTAGE CRANKCASE 230V 460V 575V HEATER WATTS 3 Ton 01638000025 01638000315 0163R00032S 40 4Ton-S Ton 0130L000175 0130L000185 0130L000195 70 *Includes C,G&H models. SS-DSG3 www.daikinac.com 27 ELECTRICAL DATA ' 3 TONS COMPRESSOR CIRCUIT 1 COMPRESSOR CIRCUIT 2 OUTDOOR FAN MOTOR INDOOR FAN MOTOR OPTIONAL POWERED POWER SUPPLY MODEL ELECTRICAL RATING CONVIENIENCE OUTLET NUMBER RLA LRA RLA LRA QTY HP FLA TYPE HP FLA FLA MCA MOP • Standard- - 74.7/24.7 40/40 OSG036XXX1D 208/230-1-60 :16.7 79.0 1 0.25 140 033 2.46 Direct Drive 7,2/6.5 31.9/31.2 45/45 D56036700(313 208/230-3-60 10.4 73.0 1 0.25 1.40 Standard- 1.50 3.40 - 16:9/16.9 25/25 Direct Drive 7.2/6.5 24,1/23.4 30/30 OSG036XXX3D 208/230-3-60 10.4 73.0 1 D 75 1.40 Standard- 0.33 2 46 179/17.9 25/25 Belt Drive 7.2/6.5 251/24.4 35/30 DSG036XXX3H 208/230-3-60 10.4 73.0 1 0 75 1.40 High Static- 1.50 4 60 19.1/19,1 25/25 Sell Drive 7.2/6.5 26.3/25.6 35/35 Standard - 9.6 IS DSG036XXX48 460 3 60 5.8 380 1 0.75 0.701.00 1.70 Belt Drive 3.3 12.9 15 DSG036XXX4H 460-3-60 5.8 38.0 1 0.25 0.70 High Static- 1.50 2.10 111,0 15 Belt Drive 3.3 13.3 15 Standard - 7.6 15 DSG036XXX7B 575-3-60 3.8 36.5 1 075 0.55 1.50 2.30 Belt Drive 2.6 10,2 15 4 Torus COMPRESSOR CIRCUIT 1 COMPRESSOR CIRCUIT 2 OUTDOOR FAN MOTOR INDOOR FAN MOTOR OPTIONAL POWERED POWER SUPPLY MODEL ELECTRICAL RATING CONVIENIENCE OUTLET NUMBER RLA LRA RLA LRA QTY HP FLA TYPE HP FLA FLA MCA MOP OSG048XXX1D 208/230-1-60 19.9 109.0 1 0.25 1.40 Standard- 0.75 2.80 - 29.0 J 29.0 45/45 Direct Drive 7.2/6.5 36.2/35.5 50/50 DSG048XXX3D 208/230-3-60 13.1 83.0 1 0.25 1.40 Standard- 0.75 2.80 20.6/20.6 30/30 Direct Drive 7.2/6.5 27.8/2/.1 40/40 OSG048XXX3B 208/230-360 I11 83.1 1. 0.25 1.40 Standard 1.00 3.40 - 71.2/21.2 30/313 '.. Belt Drive 7.2/6.5 78.4/27./ 40/40 OSG048XXX3H 208/230-3-60 13.1 83,1 1 0,25 1.40 High Static- 1.50 4.60 22.4j22.4 /35 Belt Drive 7.7/6.5 29.6/28.9 40/40 DSG048XXX4B 460 3-60 6.1 41.0 I 025 070 Standar 1.00 1.70 10.0 15 Belt Drive 3.3 13.3 15 DSG048XXX4H 460-3-60 6.1 41.0 1 0.25 0.70 I1inh Static- 1.50 2.10 10.4 15 Belt Drive 3.3 13.7 15 Standard 8.3 15 DSG048XXX7B 575-3-60 4.4 33.0 1 0.25 OSS Belt Drive 1.50 2.30 2.6 10.9 15 5 TONS COMPRESSOR CIRCUIT 1 COMPRESSOR CIRCUIT 2 OUTDOOR FAN MOTOR INDOOR FAN MOTOR OPTIONAL POWERED POWER SUPPLY MODEL ELECTRICAL RATING CONVIENIENCE OUTLET NUMBER RLA LRA RLA LRA QTY HP FLA TYPE HP FLA FLA MCA MOP Standard- - 41.3/41.3 60/60 DSG060XXX1D 208/2301-60 26.4 134.0 1 0.25 1.40 1.0,0 6.90 Direct Dr rye __. 7.2/65 485/47.8 70/70 DSG060XXX3D 208/230-3-60 16.0 110.0 1 0.25 1.40 Standar- 1.00 6.90 283/28.3 40/40 Direct Drive 7.2/6.5 35.5/34.8 SO/50 DSG060XXX38 208/230-3-60 16.0 110.0 1 025 140 5 nda rd- 1.00 3.20 ;24.6/24.6 40/40 Belt 7.2/6.5 31.8/31.1 45/45 - DSG060XXX3H 208/230-3 60 16.0 I IU.O 1 0.25 1.40 High Static- 1.50 4.80 26.2/26.2 40/40 Belt Drive 72/6.5 334/37/ 45/45 Standard- - 11.9 15 DSG060XXX48 460-3-60 7S 52.0 1 0.25 0.70 1.00 1.50 • Belt Drive 3.3 15,2 20 DSG060XXX4H 4603-60 7.8 52.0 1 0,25 0./0 HigtiStatic- 1.50 2.40 12.8 20 [telt Drive 3.3 16.1 70 Standard- - 8.9 15 DS6060XXX7B 575-3-60 5.7 38.9 1 015 0.55 1.00 1.20 - Belt Drive 2.6 11.5 15 28 www.daikinac.com SS-DSG3 3 . . a N y N Q G) W (1001 : m TOP VIEW . 31.540 ►4-11.000- -0. 7.165 1.--17.000— I. RETURN AIR DUCT " ' • , . '0/. — �.. n u 5' SUPPLY AIR DUCT P P C11 1 .m.,..itit } II ///// 7.1---- 1 i .... 12.000 p �, nu 11.265 —_i_ 10.060 1 X ++00 1' 1 OOu 4.475 1 I 6.+96 .88 8 . FLUE/VENT OUTLET ORK HOLES 33.805 m... CONDENSATE BOTH SIDES OMBUSTION AIR INLET DRAIN OUTLET AND (GAS UNITS) BOTH ENDS —LIFTING SHACKLE AS LINE ENTRANCE HOLES BOTH SIDES 20.853 73.945 AND ENDS 48.196 FRONT VIEW RIGHT END VIEW DSG036-060 0 ALL DIMENSIONS GIVEN ARE IN INCHES 3 THRU 5 TON COMMERCIAL ALL DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE IliN O DIMENSIONS(CONT.) • 19 470 CONDENSATE DRAIN BOTTOM EXIT -'•• 5.104 ••-12.000--•• • ,� • / W 0 D D° 0 O D D O Oj Y D w M • SUPPLY AIR DUCT •• N.. • 17.000 0 •• 48.312 ► i •0 I . . • 23.442 11.000 20.905 J 6.192 ' 0 o , o0 0 0. 0 '� .0 0 0 of - 5.558 •• 25.000 RETURN AIR DUCT 74.061 BASE PAN VIEW (VIEWED FROM TOP) MODEL TONNAGES 3 TON COMMERCIAL 38.840 16.555 26.055 GAS,HT PUMP,AIR CONDITIONER 4 TON COMMERCIAL 38.840 16.555 26.055 GAS,I-IT PUMP,AIR CONDITIONER STON COMMERCIAL 38.840 16.555 26.055 GAS,AIR CONDITIONER 5 TON COMMERCIAL 42.840 20.555 30.055 HT PUMP - 7.984 -= O LINE WIRE oENTRANCE I— p j f 8.555 _60 I I I 66. j TSTAT WIRE ENTRANCE 5.872 .-10.372 LEFT END VIEW 30 www.daikinac.com SS-DSG3 UNIT CLEARANCES Maintain an adequate clearance around the unit for safety,service, maintenance,and proper unit operation. Leave a clearance of 48"on all sides of the unit for possible compressor removal or service access,and • to ensure proper ventilation and condenser airflow. Do not install the unit Beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit's fresh-air intake. 48^ • • eo 48" • /°: 08 040,0 48" 48" ELECTRICAL ENTRANCE LOCATIONS High-Voltage Entrance ''.,(Remove Plug) Low-Voltage Entrance "`s. =WNW 1111=P ,12%„ E f It _ 3f"Dia. '. •,I .... 1 t i II 30X„ Power Thru „ a the Curb F .. r � . 0 0 L I r" O . 1 ' .., h4. 47b Low-Voltage Entrance CORNER&CENTER-OF-GRAVITY LOCATIONS UNIT 3-TON 4-TON 5-TON --.... ..-.- WEIGHTS WEIGHTS WEIGHTS WEIGHTS Return Corner Weight(A) 109 113 113 30" Condenser $ Coil Evaporator Coll ii Corner Weight(B) 178 192 194 t ` 1 Corner Weight(C) 109 118 119 IlC { Corner Weight(D) 179 192 194 Supply Unit Shipping Weight 600 615 620 r li Unit Operating Weight 575 640 645 �0 Note:Weights are calculated without accessories installed. [ Compressor 'a-.-"- 37" _....-......_....«.. SS-DSG3 www.daikinac.com 31 ROOF CURB INSTALLATION—RIGGING Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not • be less than 60". • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are in tended to protect unit base frame from fork lift damage. To remove the struts, ex- tract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb,duct-work should be attached to the , curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation.Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb.While rigging the unit,the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum,lower opposite end of the unit until entire unit is seated on the curb.When a rectangular cantilever curb is used,take care to center the unit.Check for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements,unit weights are shown below. Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled.The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. • Determine sufficient structural support before locating and mounting the curb and package unit. • Duct-work must be constructed using industry guidelines.The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory. • Contractor furnishes curb insulation,cant strips,flashing,and general roofing material. • Support curbs on parallel sides with roof members.To prevent damage to the unit,the roof members cannot penetrate supply and return duct openings. Note:The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. TOP VIEW • 3-D VIEW Insulated €a Panels 1624 ..2_. ,_. 52175 S/A j 14x20 Supply OPenigpuc "_ O ~ `` 31%x14 :. _" 14 56 tax / i ,£2§ Return Opening ".. , -3,1"' _404, 32 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG0360901 D/DSG048(090/115)1 D*SINGLE PHASE 208/230V/60HZ DIRECT DRIVE on YL 6.1.1 00 RD N BK RD PU• W V ® 0 • giro BK .Z 1 =GND BK BL YL COMP PU * C t• BR BL BK RD BK . '208-240/1/60 T SEE NOTES 6 v 41,_ 2� F.PU RD , o EM BR NOTE 2 .E 3 — SPEED RD el 0 O 0 J o C 208 240 ''8 v BL ALTERNATE (] TR o, n MOTOR RD 1 24V RD OTO S PU YL RD BK SEE NOTE6&7 PK BL s PU RD BL GR .= "-- —�—,J =_– YL o v EM BR T� 0 0- 3 BC > v SPEED PU TEl s ` / mn p T81 S2 SEE NOTE 7 ♦SBL pm Z F n �� v0 ♦ I BK r^ 8d Ll 480 8l 0 ��� I- I ° RD 00l ORS D OCL £d XVIN&NV£3Sfld �m " " br(1; MI= !IC m v PU Rte oz H O a RD GR— o� BR 1DC3c c0i o v PS BL •,b Pi C E3 YL— m k PU YL-1 PU m©SS* YL ,e° E —YL YL v — YL WH t - NOTE 4 RP I 2 BR PLF GR RD mC:�RD • (7 RD . nL ci(4 21=t-BK= Z X61 Q, — �BK Z BK �In 6BLa. PU PU I YL YL I �t_ BL BR BL GR of W.R. (ALT.)HONEYWELL GAS VALVE GAS VALVE I I RD WH lr(= BL PU BL i �MVIK RD PIU BL I YL GIR RD "ot_ BK GV B IVLBL 0M O 3- '' (S1 S2 Y2 W2 C RY1 W1 GI RD LPS 3 SEE NOTE RD i YL/PK ¢ ° BL I I II I GREEN JUMPER °' TEl / WII °q o SEE / FOR TO THERMOSTAT++ `_° 40 0 NOTE 9 J SMOKE/FIRE a Q. . il DETECTOR JUMPER c° ® RD - 3 E E ® OR - :s,' v RD BK RCCF BL/PK oa HPS ,� = j—@ y O RD 3v BR YL SS-DSG3 www.daikinac.com 33 WIRING DIAGRAM—DSG0360901 D/DSG048(090/115)1 D*SINGLE PHASE 208/230V/60HZ DIRECT DRIVE • , L1 SUPPLY VOLTAGE L2 COMPONENT IEGEND FACTORY WI RI NG 208-240/1160 ALS AUXILL LIMIT SWITCH LINE VOLTAGE COMP COMPRESSOR CM CONDENSER MOTOR LOW VOLTAGE C CONTACTOR .......... OPTIONAL C T1 ®Q T2 f I EM EVAPORATOR MOTOR HIGH VOLTAGE el F FUSE ---- OPTIONAL Q C Oa FS FLAME SENSOR GND EQUIPMENT GROUND LOW VOLTAGE O © GV GAS VALVE FIELD WIRING HPS HIGH PRESSURE SWITCH IIC INTEGRATED IGNITION CONTROL ....... HIGH VOLTAGE HEA1' IGN IGNITOR --- LOW VOLTAGE LS LIMIT SWITCH LPS LOW PRESSURE SWITCH WIRE CODE PCB ® FC PLF FEMALE PLUG/CONNECTOR BK BLACK RCCF RUN CAPACITOR FOR CONDENSER FAN BL BLUE I COOL c PCB PS PRESSURE SWITCH 1 RS ROLLOUT SWITCH BR BROWN SEE NOTE 2 L! ! all TB1 TERMINAL BLOCK(24V SIGNAL) GR GREEN ® Oz TR TRANSFORMER OR ORANGE 3 m Q Z VM VENT MOTOR PK PINK °. Oa r = VMR VENT MOTOR RELAY v o I /—TR - BC BLOWER CAPACITOR PU PURPLE RD RED _ O NOTES c IGN IIC 1.REPLACEMENT WIRE MUST BE THE SAME WH WHITE .� FSO FS SIZE AND TYPE OF INSULATION AS ORIGINAL. YL YELLOW (USE COPPER CONDUCTOR ONLY). BUPK BLUE WITH PINK STRIP E o 2.FOR 208 VOLT TRANSFORMER OPERATION c 0 LS MOVE BLACK WIRE FROM TERMINAL 3 TO YL/PK YELLOW WITH PINK STRIP .0 'E TERMINAL 2 ON TRANSFORMER. Y 3.FOR DIFFERENT THAN FACTORY SPEED TAP. m m ALS RS CHANGE COOLING SPEED AT COOL c f0 110 4) •.• TERMINAL.CHANGE HEATING SPEED AT THERMOSTAT++ :°43 HEAT TERMINAL ON CONTROL BOARD FIELD WIRING .E ,? ® 3 SPEED MOTOR PS RD-LOW SPEED NO ECONOMIZER (CON ® • BK-HIGH SPEED m o q cL p Q7 O 1® 1© EED 4.ACCESSORBL-MED. Y ECONOMIZER PLUG ADJACENT �, —WH W u v TO BLOWER HOUSING IN RETURN AIR ® —GR- - G c L _ — d1 LPS HPS �O� • COMPARTMENT.REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ®J —RD- - R - - © ACCESSORY. ® —YL - - Y o E 5.USE COPPER CONDUCTORS ONLY. a 0 I- 7 �� $ 6.PURPLE WIRUSE E CONNECTS C CLASS 2 ITO TRANSFORMER yRE. e —BL - - C _ T i0 ® 0/0 ©J (PIN 1). 3 7.SPEED TAP TERMINATIONS SHOWN ON !- S v TO THERMOSTAT}+ SEE DIAGRAM ARE REPRESENTATIVE,BUT ACTUAL TB1 STAT ,o ._ TERMINAL BLOCK NOTE 5 FACTORY SETTING MAY BE DIFFERENT EASED LL ON HEATING VALUE AND CAPACITY OF UNIT. WITH ECONOMIZER OPTION u 8.TO RUN DIFFERENT SPEED FOR HEATING AND c = INSTALLER/SERVICEMAN COOLING,DISCONNECT GEEEN JUMPER FROM ©i WH- -W o N "COOL"TERMINAL AND REPLACE WITH THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO APPROPRIATE SPEED TAP.THEN PLACE ® —GR- -G 'o TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS: , —RD- -R DISCONNECTED END OF JUMPER ON STATUS LIGHT EQUIP.STATUS CHECK "UNUSED'TERMINALgLEFT OPEN BY MOVING •, —YL— —Y ofO ff' ON NORMAL OPERATION - 9. STAGPE OPERATION ONLY,REMOVE • 1 v NO POWER OR CHECK INPUT POWER WHITE JUMPER.FOR 2 STAGE OPERATION, OFF CHECK FUSE ON CONTROL REMOVE JUMPER AND CONNECT W2 TO W1 O -BL - -C '° INTERNAL CONTROL REPLACE CONTROL ON THERMOSTAT. 1 BLINK IGNITION FAILURE GAS FLOW SEE UNIT RATING PLATE FOR TYPE AND SIZE OR GAS PRESSURE OF OVERCURRENT PROTECTION. TB1 STAT OPEN ROLLOUT SWITCH FLAMEVSENSOR JUNCTION..i. Z GAS EQUIPMENT ph 2 STAGE COOLING ALVE Z OR FLAME ROLLOUT TERMINAL a GROUND OPEN AUX.LIMIT SWITCH BAD SWITCH INTERNAL TO FIELD GROUND' L —WH- -W Z AUX.LIMIT OPEN INTEGRATED PRESSURE SWITCH CHECK CONTROL FIELD SPLICE 'V' GR- -G CC 2 BLINKS OPEN PRESSURE SWITCH COMAEcnOONN m SWITCH(TEMP)47 RD R S 3 BLINKS PRESSURE SWITCH CLOSED CHECK SWITCH(PRESS.) —YL — —Y1 WITHOUT INDUCER ON PRESSURE SWITCH IGNITER 'VIM- a MAIN LIMIT OPEN OVERCURRENT� PK- Y2 4 BLINKS OPEN LIMIT SWITCH PROT.DEVICE BAD SWITCH 5BLINKS FALSE FLAME SENSED STICKING GAS VALVE -,::•' BL C 6 BLINKS COMPRESSOR 3 MIN.COMP. . - OUTPUT DELAY ANTI-CYCLE TIMER ..�. ', TEl STAT t m 208-240/1/60 0140L02898-B 3 ..c o = E 1 m . Q `O I° o u a o m . v .3 0 c +. . E v 0 o Y y m.J o o c 3v ` 34 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG0360451 D*SINGLE PHASE 208/230V/60HZ DIRECT DRIVE co YL O O RD n�i RD 0 BK 7 v PU e-I lego BK COMP IBK• 1 GND BL o YL PU BR m C ®` 0— BL BK RD 2D8-24D/1/60 BK SEE NOTE 5 v — RD o v n� FIC2 P ° `o EM BR > t4 ...±„... 3 SPEED RD : NOTE 2 . V. O 0 ® = o BL ALTERNATE RD C 208 240 N v MOTOR TR RD 6-WIRES ? = v RD 24V� BK SEE NOTE 6 8 7 PU YL RD - T PU PK - BL BL GR Y I I YL v BR up EM - - 3 SPEED BC .> PU"O v m6))p ODD m m $ EL SEE NOTE 7 p r.' Z r LLL n o f co mll I—' OT v o 4110.. D BK ( .Zd° Goo I �� _ o RD cR a tu 0 ?9ZEd XVW V£aSfd IIC A cD . o clIAI RD m Pu CC. vs RD z GR— q ai B LOl2 o v PS BL t t t Gi YL PU / YL6 a%� PU a o YL YL ° E O YL YL lAiH , W _ e NOTE4 R� = o BR PLF GR RD r:G'I® R cnORD • C' U. 0t=111••• •BK BK PU .O HIO BL �BK Cc PU YL Q YL c�= `" BL BL GR 0;1 t� W.R. (ALT.)HONEYWELL H D_ a GAS VALVE GAS VALVE BR RD W1- EL •RIPU BL MV PI I R IU BL I I bRRD _ BKVp • BL MV LPS °1 ab ?Si S2 Y2 C R Y1W1 GI RD ♦�YL/PK 3 _ BL TB1/ 6 1811SEE NOTE 8- MIE v ® FOR TO THERMOSTAT+i V a o SMOKE/FIRE DETECTOR JUMPER GREEN JUMPER m 6 FS RD c .Ev® OR v .3 g RD1,1 BK • o v v BL/PK . RCCF HPS -' BR O ? O RDS § E g YL' .'" SS-DSG3 wwwdaikinac.com 35 WIRING DIAGRAM—DSG0360451 D*SINGLE PHASE 208/230V/60HZ DIRECT DRIVE , t. L1 SUPPLY VOLTAGE L2 COMPONENT LEGEND FACTORY WIRING 208-240/1160 ALS AUXILLARY LIMIT SWITCH LINE VOLTAGE COMP COMPRESSOR LOW VOLTAGE C CM CONDENSER MOTOR ..m.. . OPTIONAL • C T1 le T2 I i EM EVAPORATTOR MOTOR HIGH VOLTAGE I $ F FUSE ---- OPTIONAL Q ©Oa FS FLAME SENSOR LOW VOLTAGE 10 a) GND EQUIPMENT GROUND FIELD WIRING GV GAS VALVE ......m. HIGH VOLTAGE • HPS HIGH PRESSURE SWITCH LOW VOLTAGE IIC INTEGRATED IGNITION CONTROL HEAT IGN IGNITOR WIRE CODE LS LIMIT SWITCH BK BLACK PCB CD FC LPS LOW PRESSURE SWITCH BL BLUE PLF FEMALE PLUG/CONNECTOR BR BROWN \�, COOL PCB PS PRESSURE SWITCH GR GREEN •\ m . RCCF RUN CAPACITOR FOR CONDENSER FAN OR ORANGE SEE NOTE 2 L— ® RS ROLLOUT SWITCH LIT-0 PK PINK ® 02 TEl TB1 TERMINAL BLOCK(24V SIGNAL) PU PURPLE o d _ TR TRANSFORMER o.-o TR VM VENT MOTOR RD RED TB11 O VMR RELAY WH WHITE a o 0 IGN IIC BC BLOWER CAPACITOR YL YELLOW c c NOTES BUPK BLUE WITH c FSOIFS 1.REPLACEMENT WIRE MUST BE THE SAME PINK STRIP c SIZE AND TYPE OF INSULATION AS ORIGINAL. YUPK YELLOW WITH 0 o 1—F I (USE COPPER CONDUCTOR ONLY). PINK STRIP LS 2.FOR 208 VOLT TRANSFORMER OPERATION E a MOVE BLACK WIRE FROM TERMINAL 3 TO ai ALS .RE TERMINAL 2 ON TRANSFORMER. Q. r00a IIC Q e�• 3.FOR DIFFERENT THAN FACTORY SPEED TAP. THERMOSTAT++ CHANGE COOLING SPEED AT COOL �°• O Z.- 1°:_l TERMINAL.CHANGE HEATING SPEED AT FIELD WIRING c Y HEAT TERMINAL ON CONTROL BOARD ai NO ECONOMIZER ECON 00 3 SPEED MOTORo 0 0 O7O ©( RD-LOW SPEED El- 2_, —WH- - W °pBL-MED.SPEED —OR— — GL _ _ _ LPS HPS .0. BK-HIGH SPEED —RD— — R °,,_ _ _ 4.ACCESSORY ECONOMIZER PLUG ADJACENT— TO BLOWER HOUSING IN RETURN AIR —YL — — Y fO0*Q COMPARTMENT.REMOVE MALE PLUG AND o E r , "�® ACCESSORATTACH MALE PLUG TO ECONOMIZER Y. —BL — — C CPG ® 4 ® ® 9 ©J Q 5.USE COPPER CONDUCTORS ONLY. 50 o IT PLF "1"1"USE NEC CLASS WIRE. fl- E TO THERMOSTAT++ TB1 SEE TB1 STAT TERMINAL BLOCK NOTE 1 6.PURPLE WIRE CONNECTS TO TRANSFORMER ._ (PIN 1). WITH ECONOMIZER OPTION ii 7.SPEED TAP TERMINATIONS SHOWN ON m c INSTALLER/SERVICEMAN DIAGRAM ARE REPRESENTATIVE,BUT ACTUAL W, —WH— —W o N FACTORY SETTING MAY BE DIFFERENT BASED THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO Q —GR— —G 8 S ON HEATING VALUE AND CAPACITY OF UNIT. ♦ a TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS. 8.TO RUN DIFFERENT SPEED FOR HEATING AND - —RD— —R o COOLING,DISCONNECT GEEEN JUMPER FROM STATUS LIGHT EQUIP.STATUS CHECK �jl —YL— —Y ON NORMAL OPERATION - "COLO TERMINAL AND REPLACEPWITH APPROPRIATE SPEED TAP. THEN PLACE OFF NO POWER OR CHECK INPUT POWER DISCONNECTED END OF JUMPER ON INTERNAL CONTROL CHECK FUSE ON CONTROL O —BL — —C FAULT REPLACE CONTROL "TNUSPE"TERMINAL LEFT OPEN BY MOVING m THE SPEED TAP. 2 1 BLINK IGNITION FAILURE GAS FLOW SEE UNIT RATING PLATE FOR TYPE AND SIZE STAT OR GAS PRESSURE OF OVERCURRENT PROTECTION. TB1 OPEN ROLLOUT GAS VALVE SWITCH FLAME SENSOR .UNCTION.4 EQUIPMENT /')7 2 STAGE COOLING (9 OR FLAME ROLLOUT TERMINAL 4 GROUND Z OPEN AUX.LIMIT BAD SWITCH INTERNAL TO FIELD GROUND �♦ WH _W SWITCH AUX.LIMIT OPEN INTEGRATED - —GR- -G Z CONTROL FIELD SPLICE 2 BLINKS PRESSURE SWITCH CHECK C♦ _R CC — OPEN PRESSURE SWITCH PLUG m E. RD— 3 BLINKS PRESSURE SWITCH CLOSED CHECKcoNNEcnoN SWITCH cTEMPI�'f` I�1 —YL — —Y1 WITHOUT INDUCER ON PRESSURE SWITCH SWITCH(PRESS I•� SNEER .yw 4 BLINKS OPEN LIMIT SWITCH OVERCURRENT,...RODEVI al —PK— —y2 MAIN LIMIT OPEN PROT.DEwcEl BAD SWITCH Q —BL— —C 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE V '.`' 6 BLINKS COMPRESSOR 3 MIN.COMP. I '• OUTPUT DELAY ANTI-CYCLE TIMER TB1 STAT v ab 208-240/1/60 0140L02900-13 _ 3 a o .§ = E f %0) 0 m " ‘,. a 2 m r c E :3 E Y i No c _ 3 2 a 36 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG060*1 D SINGLE PHASE 208/230V/60HZ DIRECT DRIVE N e-1 6, YL o RD 0 BK RD ti O 0 PU 0 . pTpTp BK I 1 T _ GND —BL o YL COMP L1 O L2 \ \. PU • BK\ RD —POWER SUPPLY •\ S BR BK • • BKI l — —SEE NOTE 5 3 I L 4 v 6 GI BK I RI MBK RD NOTE 2 7-5 RD BK g o BL , 0 O 0 _= = C los 240 go24 EC LGN Rp 24V - E EM VMR BL = T1T2T3T4T5 RD BL GR PK `0 2 NOTE 3 8,7 YL/PK— �_ BK _ ' o WH PU BL = > o OR BR YL v !_PS TB1[trial 5 1 5 v o WH 9 f - YL HPS e[T 0--OR— I9 2 a PU q l - J v L_RDR �GR— `o v YL/PK —RD - Q DL QN m g > PU YL-1 PU O YL IN YL YL , ,, GR— YL —R YLWH t BR WH NOTE 4\PLF I I _ YL BL YLU OO ©0-BLRD-- �C3---RD� C7 -©d0 WH z O O OO —BR RD—�`' SEE BR CC YL 3 NOTE 6 Q PU - Pu BL c , _,_, BL c c _, W.R. (ALT.)HONEYWELL YL RD WH c-c s GAS VALVE GAS VALVE "C , nc=j Milp •MGVPI PIU EL BiR�R II BL R. aBL •My 51S2Y2Y1 R W1®J2 G BL I > v I 3 .. BR i i i i WH i TB1 YL WH a ° BL SEE m • ® SMOKE/FIRE TO THERMOSTAT++ NOTE s DETECTOR REPLACES FS I RD JUMPER WIRE IIGNI OR 2 c f • WH BK 0 :3 BL IP El'," v YL RCCF YL WH BR BR RD v g SS-DSG3 www.daikinac.com 37 WIRING DIAGRAM—DSG060*1D SINGLE PHASE 208/230V/60HZ DIRECT DRIVE • ' COMPONENT LEGEND L1 SUPPLY VOLTAGE L2 240/1/60 ALS AUXILIARY LIMIT SWITCH FACTORY WIRING COMP COMPRESSOR LINE VOLTAGE CM CONDENSER MOTOR LOW VOLTAGE C CONTACTOR .. EM EVAPORATOR MOTOR ----OPTIONAL HIGH VOLTAGE C T1 G© T2 I 18 F FUSE ----OPTIONAL LOW VOLTAGE II © © ©4D� GN EQUIP SENSOR GND EQUIPMENT GROUND FIELD WIRING 0W© 1 GV GAS VALVE — —HIGH VOLTAGE HPS HIGH PRESSURE SWITCH — —LOW VOLTAGE IIC INTEGRATED IGNITION CONTROL IGN IGNITOR ®© LPS LOW PRESSURE SWITCH WIRE CODE VMR LS LIMIT SWITCH 1• PLF FEMALE PLUG/CONNECTOR BK BLACK SEE NOTE 2 L© O I ® PS PRESSURE SWITCH BL BLUE \A © NO 0 RCCF RUN CAPACITOR FOR COMPRESSOR/FAN BR BROWN •\ RS ROLLOUT SWITCH GR GREEN TR - TEl TERMINAL BLOCK(24V SIGNAL) v N 6 7 NOTE 6 TR TRANSFORMER OR ORANGE 0 m ® VM VENT MOTOR PK PINK 0 v IGN— TEl IIC VMR VENT MOTOR RELAY PU PURPLE v o rt 0 FSO I FS OIO 11d' NOTES RD RED a © •• 1T®O • 1.REPLACEMENT WIRE MUST BE THE SAME WH WHITE S Q OIO �� SIZE AND TYPE OF INSULATION AS ORIGINAL. YL YELLOW :E. (USE COPPER CONDUCTOR ONLY). BL/PK BLUE WITH PINK STRIP D1Q O • 2.FOR 208 VOLT TRANSFORMER OPERATIONYUPK YELLOW WITH PINK STRIP oMOVE BLACK WIRE FROM TERMINAL 3 TO m vOLS_ VMR • • TB1 TERMINAL 2 ON TRANSFORMER. y a. I® p 3.FOR DIFFERENT THAN FACTORY SPEED TAP. pp °O 110 • ALS RS CHANGE COOLING SPEED AT MOTOR T4 AND f0m © • • • • 000 T5 TERMINALS.CHANGE HEATING SPEED AT -,iE .6 MOTOR Tt.T2,AND T3 TERMINALS THERMOSTAT ++0 PS COOLING SPEED(YELLOW WIRE) FIELD WIRING c Y /EECCO�N® `� • T3-LOW SPEED NO ECONOMIZER `o a •®• • T4-HIGH SPEED HEATING SPEED(WHITE WIRE) et‘ —WH— — W m n. u N T1-LOW SPEED(0701 © —GR— — G S o L ' C/ /--p T2-MED.SPEED _RD_ — LPS HPS ..Qp7 3 4.ACCESSORYEC8IS'OM1ZER PLUG ADJACENT a _YL — — Y E E 5 4 ' TO BLOWER HOUSING IN RETURN AIR �y v o _ - COMPARTMENT.REMOVE MALE PLUG AND �L' _cl ATTACH FEMALE PLUG TO ECONOMIZER o ® S1 ® W1 a ® Y1 LY 21 © PLF Q3�2 ACCESSORY. —BL — — C v -o L_ Y J TB1 NOTE 4 IT 5.USE COPPER CONDUCTORS ONLY. n 22 TO THERMOSTAT -1-1-USE NEC CLASS 2 WIRE. TERMINAL BLOCK++ 6.L1 AND L2 ON ICC CONTROL IS 24V INPUT. TEl STAT = ro •7, 7.SPEED TAP TERMINATIONS SHOWN ON WITH ECONOMIZER OPTION DIAGRAM ARE REPRESENTATIVE,BUT INSTALLER/SERVICEMAN ACTUAL FACTORY SETTINGS MAY BE _ v • THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO DIFFERENT BASED ON THE HEATING VALUE �j —WH —W o v OF THE UNIT. —GR— —G 9 5 TROUBLESHOOTING THIS APPLIANCE.STATUS LIGHT CODES ARE AS FOLLOWS: 8.FOR LOW STAGE OPERATION ONLY,REMOVE —RD— —R p WHITE JUMPER.FOR 2 STAGE OPERATION, STATUS LIGHT EQUIP.STATUS CHECK REMOVE JUMPER AND CONNECT W2 TO W2 31 —YL — —Y T ON NORMAL OPERATION - ON THERMOSTAT. E OFF NO POWER OR CHECK INPUT POWER SEE UNIT RATING PLATE FOR TYPE AND SIZE �C INTERNAL CONTROL CHECK FUSE 01 CONTROL OF OVER CURRENT PROTECTION. FAULT REPLACE CONTROL 1 —EL — —C o 1 BLINK IGNITION FAILURE GAS FLOW JUNCTION EQUIPMENT /'T7 2 OR GAS PRESSURE TERMINAL-o- GROUND STAT OPEN ROLLOUT GAS VALVE TB1 SWITCH FLAME SENSOR INTERNAL TO FIELD GROUND W 2 STAGE COOLING CD OR FLAME ROLLOUT INTEGRATED - OPEN AUX.LIMIT BAD SWITCH CONTROL FIELD SPLICE �� —WH— —W Z SWITCH AUX.LIMIT OPEN PLUG m Z 2 BLINKS PRESSURE SWITCH CHECK CONNECTION SWITCH(TEMP)°TH° O♦ —GR— —G CC OPEN PRESSURE SWITCH SWITCH(PRESS.)•a• IGNITER Ve'in © —RD —R Q 3 BLINKS PRESSURE SWITCH CLOSED CHECK OVERCUR RENT ail —YL — —Y1 WITHOUT INDUCER ON PRESSURE SWITCH -El- 4 4 BLINKS OPEN LIMIT SWITCH MAIN LIMIT OPEN PROT.DEVICE 0 —PK— —Y2 BAD SWITCH • a —BL — —C 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE i 6 BLINKS COMPRESSOR 3 MIN.COMP. ;la'1 OUTPUT DELAY ANTI-CYCLE TIMER • TB1 STAT o L c 240/1/60 0140L02912-B 3 a a 3 cC ;, ,. o u t o a 9 m , c . . .0 • E°-•' • N CU d Y L PO o" o 3 v 38 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG036090/DSG048(090/115)3D*THREE PHASE 208/230V/60HZDIRECT DRIVE a YL a O • RD Ln • BK _ RD O O J PU O cr N O a♦ ii, BK _ TT3 1 T GND BK BL o COMP YL PU I 4) C L L3 • BR BL BK RD\ L POWERSUPPLY BK �208-240/3/60 0 SEE NOTE 5 2 v 0o FPU •'D co > EM BR ✓NOTE 2 c 3 SPEED = RD el 0 O 0 g C 208 240 , v BL ALTERNATE TR 80 (� ai MOTOR R• I 24V(. -P L9 RD 6-WIRES PU YL RD m BK SEE NOTE 6&7 PK BL E .B- PU PU c•-• RI B'I i v EM BR� I l ca ao v 3 SPEED BC ? ` PU'w...0, 41111 ••BL SEE NOTE 7 v o • BK "/17 £' ll^^ I— —1BBD Zl� RD T 3_OR_ r _ O.LI £d Zd �9m aoJ XVWdW/ £9Snd lc c ILI PU imgo'Rg J o v RD z GR — ) n BL ,l�l,Le; YL— PU �� YL--i YL PU m©a'la® YL g • YL YL WH co RDI 2 ° BR NOTE 4 GR PLF f.�0 • RD , rCC) R Z BK PU P e 0 BL �,_ BK et YL PU YL <-. W.R. BL GR 1) Ih ! .)HONEYWELL(ALTGWH i gR BL PU •MV �U BL JYLftJR RD O BK L• � III GV BR 'C LPS 3 - _ IYL/PK ¢ `o3 BL k: MV IS1 S2 Y2 W2 C R Y1 W1 GI RD L, 11 ; . f SEE NOTE 8 =,o E .. BL I 1 1 I 1 GREEN JUMPER B t 7 FOR SMOKE/FIRE TB1 WH = N GI DETECTOR REPLACE TO THERMOSTAT- SEE o a JUMPER I FS i RD NOTE 9 -' �IGN OR NOTE E RD L, v v BKrd FC BL/PK v o HPS c BR 4 o RDS SS-DSG3 www.daikinac.com 39 WIRING DIAGRAM—DSG036090/DSG048(090/115)3D*THREE PHASE 208/230V/60HZ DIRECT DRIVE L1 SUPPLY VOLTAGE L2 L3 COMPONENT FGFND FACTORY WIRING 208-240/3/60 ALS AUXILLARY LIMIT SWITCH COMP COMPRESSOR LINE VOLTAGE CM CONDENSER MOTOR LOW VOLTAGE C CONTACTOR ..,,..... OPTIONAL ` T2 C EM EVAPORATOR MOTOR HIGH VOLTAGE C Ti ��� I F FUSE (11 FC FAN CAPACITOR 13 C FS FLAME SENSOR FIELD WIRING 4:1GND EQUIPMENT GROUND == HIGH VOLTAGE GV GAS VALVE LOW VOLTAGE HPS HIGH PRESSURE SWITCH IIC INTEGRATED IGNITION CONTROL WIRE CODE HEAT IGN IGNITOR LS LIMIT SWITCH BK BLACK LPS LOW PRESSURE SWITCH BL BLUE PCB 0 FC PCB PLF FEMALE PLUG/CONNECTOR BR BROWN ® 1-15 PS PRESSURE SWITCH GR GREEN COOL = SEENOTE2 J RS ROLLOUT SWITCH OR ORANGE TSI TERMINAL BLOCK)24V SIGNAL) © O o TR TRANSFORMER PK PINK _ Z VM VENT MOTOR PU PURPLE 0- 1 r TB1� `TheTh�n TP' _ VMR VENT MOTOR RELAY RD RED - a o " BC BLOWER CAPACITOR WH WHITE O IGN IIC O NOTES YL YELLOW . FSO ( FS 1.REPLACEMENT WIRE MUST BE THE SAME BL/PK BLUE WITH PINK STRIP — F SIZE AND TYPE OF INSULATION AS ORIGINAL. YL/PK YELLOW WITH PINK m - (USE COPPER CONDUCTOR ONLY). STRIP o 4 2 FOR 208 VOLT TRANSFORMER OPERATION ' po. LS I MOVE BLACK WIRE FROM TERMINAL 3 TO t,, O5 0 TERMINAL 2 ON TRANSFORMER. pp0 3.FOR DIFFERENT THAN FACTORY SPEED TAP. =oE ALS PS CHANGE COOLING SPEED AT COOL IIC • • • • 00• TERMINAL CHANGE HEATING SPEED AT THERMOSTAT++. 2 -p HEAT TERMINAL ON CONTROL BOARD E N 6 3 SPEED MOTOR FIELD WIRING . CD /PS RD-LOW SPEED NO ECONOMIZER C o EMS ® O� • - BL-MED.SPEED , m a O00 ® © BK-HIGHSPEED © —WH— — W N S 7 1 4,ACCESSORY ECONOMIZER PLUG ADJACENT —GR— — G TO BLOWER HOUSING IN RETURN AIR © C L LPS HPS •O• • COMPARTMENT.REMOVE MALE PLUG AND O� —RD— — R 3 ATTACH FEMALE PLUG TO ECONOMIZER ♦ 5 — —• — ACCESSORY. ® —YL — — Y O E 5.USE COPPER CONDUCTORS ONLY. 0 IM ++USE NEC CLASS 2 WIRE. p A• O S.PURPLE WIRE CONNECTS TO TRANSFORMER e —BL — — C ! LOR 2 G OW Y Y2 00,TB1 PL (PIN 1). E ++ 7.SPEED TAP TERMINATIONS SHOWN ON n v TO THERMOSTAT F (RSTAT SEE DIAGRAM ARE REPRESENTATIVE,BUT ACTUAL = TERMINAL BLOCK NOTE q FACTORY SETTING MAY BE DIFFERENT BASED TEl '• LL ON HEATING VALUE AND CAPACITY OF UNIT. WITH ECONOMIZER OPTION ., J.TO RUN DIFFERENT SPEED FOR HEATING AND N 5 COOLING,DISCONNECT GEEEN JUMPER FROM c N INSTALLER/SERVICEMAN •COOL"TERMINAL AND REPLACE WITH © —WH— —W O al THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO APPROPRIATE SPEED TAP.THEN PLACE Q —GR— —G ,L, fl- DISCONNECTED END OF JUMPER ON O al TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS: "UNUSED"TERMINAL LEFT OPEN BY MOVING Q —RD— —R _oTHE SPEED TAP. >- STATUS LIGHT EQUIP.STATUS CHECK NIP -YL— —Y "gB.FOR LOW STAGE OPERATION ONLY,REMOVE ON NORMAL OPERATION - WHITE JUMPER.FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2TO W7 NO POWER TR CHICK IEE ON FOWLS ON THERMOSTAT. t OFF I INTERNAL CONTROL CHECKFLEEC ONTfRCL SEE UNIT RATING PLATE FOR TYPE AND SIZE OF O BL —C tyA o FAULT REPLACE CONTROL = IGNITION FAILURE GAS FLOW OVERCURRENT PROTECTION, OR GAS PRESSURE TEl STAT (� OPEN ROLLOUT GAS VALVE JUNCTION 1 EQUIPMENT /4'f V 1 BLINK SWITCH FLAME SENSOR TERMINAL GROUND 2 STAGE COOLING z OR FLAME ROLLOUT NTESNAL TO FIELD GROUND Mir L —WH— ---WITOPEN AUX.LIMIT BAD SWCH INTEGRATED—SWITCH AUX.LIMIT OPEN CONTROL FIELDSPLICE —GR— —G2 BLINKS PRESSURE NWffCH CHECK CONNECTION mSWITCH(TENP) —RD— —ROPEN PRESSURE SWITCH �3 BLINKS PRESSURE SWITCH CLOSED CHECK SWITCH(PRESS)•= IGNITER ,Mr —YL — —Y1 WITHOUT INDUCER ON PRESSURE SWITCH OVERCURRENT MAIN LIMIT OPEN PROT.DEVICE -PK— —Y2 4 BLINKS OPEN LIMIT SWITCH BAD SWITCH O —BL— —C 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE 43:x• 6 BLINKS COMPRESSOR 3 MIN.COMP. STAT OUTPUT DELAY ANTI-CYCLE TIMER �. .� TB1 i v g 208-240/3/60 0140L05404-A 3 " E Zt o .3 8Ev S f0 0 U t, a p m .3 S v C u E vv _ 0 •5 C °1 Y 3 v E 3 40 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG0360453D*/THREE PHASE 208/230V/60HZDIRECT DRIVE a YL o c RDR o BK -5• c PU o • ON% t BK T, t GND IBK BL .- • • YL COMP PU 0 C 0 y S BR BL BK RD\ L POWERSUPPLY 41111. BK 208-240/3/60 - SEE NOTE 5 ° v o L EM BR • NOTE 2 = 3 SPEED RP S 0 0 0 's o Zr FOP C 208 240 `-" n BL ALTERNATE TR CO RD MOTOR PU RD Q 24V I YL RD BK 6-WIRES PK3'. Y PU SEE NOTE 6&7 RD I BL BL OR o p 1 moo` EM BR••6-...\ 42 3 SPEED BC o PU—F , T 4�BL SEE NOTE 7 _ Rm F'l ^ 9jL:ro; � �, R— R PU q� IIC o v —RD - " GR- o BR ; WIRING DIAGRAM—DSG0360453D*THREE PHASE 208/230V/60HZ DIRECT DRIVE • COMPONENT LEGEND L1 SUPPLY VOLTAGE L2 L3 ALS AUXILLARY LIMIT SWITCH FACTORY WIRING 208-240/3/60 COMP COMPRESSOR CM CONDENSER MOTOR LINE VOLTAGE C CONTACTOR LOW VOLTAGE EM EVAPORATOR MOTOR ..... .. OPTIONAL • T2 C C Ti i F FUSE HIGH VOLTAGE AN al �IICCI,J�P� FC FLAME SE SGO ---- OPTIONAL FS FLAME SENSOR jT3 C GND EQUIPMENT GROUND LOW VOLTAGE GV GAS VALVE HPS HIGH PRESSURE SWITCH IIC INTEGRATED IGNITION CONTROL FIELD WIRING IGN IGNITOR ... HIGH VOLTAGE LS LIMO'SWITCH --- LOW VOLTAGE HEAT LPS LOW PRESSURE SWITCH PLF FEMALE PLUG/CONNECTOR PCB -0FC PS PRESSURE SWITCH WIRE CODE ®� PCB RS ROLLOUT SWITCH BK BLACK 1 'l TEl TERMINAL BLOCK(24V SIGNAL) COOL SEE NOTE 2 © �E, j TR TRANSFORMER BL BLUE v m VM VENT MOTOR BR BROWN 3 © O2 Q VMR VENT MOTOR RELAY GR GREEN a v TR NOTES BLOWER CAPACITOR OR ORANGE o. o — 1.REPLACEMENT WIRE MUST BE THE SAME PK PINK 0 O IGN IC O PU PURPLE SIZE AND TYPE OF INSULATION AS ORIGINAL. � c (USE COPPER CONDUCTOR ONLY). RD RED F FSO I FS 2.FOR 208 VOLT TRANSFORMER OPERATION WH WHITE .� o MOVE BLACK WIRE FROM TERMINAL 3 TO YL YELLOW c TERMINAL 2 ON TRANSFORMER. v 4 3.FOR DIFFERENT THAN FACTORY SPEED TAP. BL/PK BLUE WITH PINK STRIP a L CHANGE COOLING SPEED AT COOL YL/PK YELLOW WITH PINK STRIP v 6 I �" TERMINAL.CHANGE HEATING SPEED AT E g IIC •ALS •RS• HEAT TERMINAL ON CONTROL BOARD ® • • 3SPEEDMOTOR THERMOSTAT++ RD-LOW SPEED FIELD WIRING s y ® BL-MED.SPEED P� I BK-HIGHSPEED `o a ® 0O"---��I • 4.ACCESSORY ECONOMIZER PLUG ADJACENT NO ECONOMIZER ¢p a ECO I TO BLOWER HOUSING IN RETURN AIR — O9 7 1 • COMPARTMENT.REMOVE MALE PLUG AND L —WH — W .E c OO ® © •O ATTACH FEMALE PLUG TO ECONOMIZER —GR— — G N L — —• LPS HPS ACCESSORY. —RD— — R v 5.USE COPPER CONDUCTORS ONLY. o E •O O: ++USE NEC CLASS 2 WIRE. —YL — — Y6.PURPLE WIRE CONNECTS TO TRANSFORMER - No �©0 (PIN 1). -°cr © //�C—� —c_. •� PLF ©©O 7.SPEED TAP TERMINATIONS SHOWN ON 3 L� la W ® ©J DIAGRAM ARE REPRESENTATIVE,BUT ACTUAL —BL C o.v NOTE 4 FACTORY SETTING MAYBE DIFFERENT BASED ON HEATING VALUE AND CAPACITY OF UNIT. STAT m LL TO THERMOSTAT++ 8.TO RUN DIFFERENT SPEED FOR HEATING AND TB1 TERMINAL BLOCK COOLING,DISCONNECT GEEEN JUMPER FROM WITH ECONOMIZER OPTION v " -- - 'COOL"TERMINAL AND REPLACE WITH c c APPROPRIATE SPEED TAP.THEN PLACE c v INSTALLER/SERVICEMAN DISCONNECTED END OF JUMPER ON W —WH— W o m THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO "UNUSED"TERMINAL LEFT OPEN BY MOVING Q� —GR— —G o v TROUBLESHOOTING THIS APPLIANCE.STATUS LIGHT CODES ARE AS FOLLOWS: THE SPEED TAP. C —RD- -R k >' SEE UNIT RATING PLATE FOR TYPE AND SIZE OF Al A STATUS LIGHT EQUIP.STATUS CHECK —YL— —Y c OVERCURRENT PROTECTION. J ON NORMAL OPERATION - el v el C OFF NO POWER OR CHECK INPUT POWER INTERNAL CONTROL CHECK FUSE ON CONTROL EQUIPMENT el —BL — —C 2 r FAULT REPLACE CONTROL JUNCTION GROUND /47 1 BLINK IGNITION FAILURE GAS FLOW TERMINAL 1 TB1 STAT OR GAS PRESSURE LD OPEN ROLLOUT GAS VALVE FIELD GROUND INTERNAL TO SWITCH FLAME SENSOR STAGE COOLING OR FLAME ROLLOUT INTEGRATED— FIELD SPLICE OPEN AUX.LIMIT BAD SWITCH CONTROL W� —WH— —W CC SWITCH AUX LIMIT OPEN PLUG CONNECTION I= Q, OPEN PRESSURE SWITCH —GR— —G PRESSURE SWITCH CHECK SWITCH(TEMP) 2 BLINKS SWITCH(PRESS.) —RD— —R 3 BLINKS PRESSURE SWITCH CLOSED CHECK OVERCURRENT IGNITER • Rr k, —YL — —Y1 PROT. WITHOUT INDUCER ON PRESSURE SWITCH D � 1 DEVICE 1s —PK— —Y2 `\ 4 BLINKS MAIN LIMIT OPEN OPEN LIMIT SWITCH BAD SWITCH 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE h'TF O —BL— —C 6 BLINKS COMPRESSOR 3 MIN.COMP. I. STAT >t m OUTPUT DELAY ANTI-CYCLE TIMER tiz••. . TB1 3 208-240/3/60 0140L05406.A a o 3 = E „ E° T v Q L O c . u . p N E a 0 v v Y i 0 co",p w Y N c 42 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG060(090/140)3D*THREE PHASE 208/230V/60HZ DIRECT DR/VE a YL N Cr RD Ln BK RI o 0 a PU r•I • o BK T Q _ GND • o YL COMP L1 C L L O BK \a BL PU POWER SUPPLY ��B' B RD 240/3/60 3 1...� SEE NOTE 5 Q BK c RD _ , NOTE 2 BK BK. . BK 0 0 0c o RDIg C 208 240 = °' BL , GR1 TR El* _▪ LL RD 24V _ BL OR YL RD C L G N VMR WH EM RD BL GR PK v 0 n IBK o T1 T2 73 T4 Ta — c �- BL m v 7 WH PU v m' OR BR YL TB1 o E v o • • b =]6 `_ „ I—-1 o▪ O -W . NOTE 3&7 !r-r (/� I—I = Q1 ' •YL I II TOR JJi9m L N CS) PU— . 1 R - - GR— a v PS EL!{�N C•®-= YL 24 E PU / YL-, PU O fry 0 YL g v YL p YL YL WH 2 91 NOTE 4 RI I BR WH _ PLF • 3 9 GR RC2.RDS Z BL YLBL of-3.WH —�5/U® Z 1 4 Q —RDBR _ SEE Q YL NOTE 6 PU —PU YL BLS -] LPS BL moo[_] I C . VV. W R. (ALT.)HONEYELL •i, •'...- YL/PK GAS VALVE GAS VALVE BR RD WH BR I I "> PU I MGV pIKRB Pi iLBL BL I I I GR BL BL v I 17 aill MV St S2Y2Y1 C R W 1 W2 G I v BR ' I I m I ` I BL I I I I WH `I TB1 4 SEE YL WH IIISMOKE/FIR DET DETECTOR TO THERMOSTAT` NOTE 8 BL/PK HPS 29 o REPLACES ® ++ RD o- ~' JUMPER WIRE °1▪ 3 S • aK ass OR ,,=_,,,, v WH •• = o 0 BL °0.- YL FC - u - v g WH BR BR. ,...(0RD. SS-DSG3 www.daikinac.com 43 WIRING DIAGRAM—DSG060(090/140)3D*THREE PHASE 208/230V/60HZ DIRECT DRIVE L1 SUPPLY VOLTAGE L2 L3 COMPONENT IFGENn 240/3/60 ALS AUXILIARY LIMIT SWITCH FACTORY WIRING COMP COMPRESSOR ALINE VOLTAGE CM CONDENSER MOTOR LOW VOLTAGE C CONTACTOR • C Ti .... OPTIONAL HIGH VOLTAGE . T2 C EISb FM EVAPFUSEORATOR MOTOR �__. OPTIONAL LOW VOLTAGE , I � � FC FAN CAPACITOR hillar.uF 0 T3 C FS FLAME SENSOR FIELD WIRING GND EQUIPMENT GROUND THIGH VOLTAGE GV GAS VALVE --LOW VOLTAGE HPS HIGH PRESSURE SWITCH E IIC INTEGRATED IGNITION CONTROL 0®CI IGN IGNITOR TCH BL WIRE CODE LS LIMIT SWITCH BK BLACK \. SEE NOTE2 jrll1111MMIIII 1111 -Q ® RESSURE PLF FEMALPS LOWLEFLUG/CONNIECTOR BR BROWN .\ O Q PS PRESSURE SWITCH GR GREEN RS ROLLOUT SWITCH OR ORANGE `m si, TR TB1 TERMINAL BLOCK(24V SIGNAL) T11" NOTE 6 PK PINK NOTE6 TR TRANSFORMER a !3' L2 VM VENT MOTOR PU PURPLE v o IGN T+-1 IIC VMR VENT MOTOR RELAY RD RED FS FS Ob-2 NOTES WH WHITE F O•�3 ®➢ 1.REPLACEMENT WIRE MUST BE THE SAME YL YELLOW '3 c O 1 OHO 4 SIZE AND TYPE OF INSULATION AS ORIGINAL. gL/pK BLUE WITH PINK STRIP y; •_•LL•_5 NOTE 3 (USE COPPER CONDUCTOR ONLY), c TEl YL/PK YELLOW WITH PINK STRIP 'c p D1 • 2.FOR 208 VOLT TRANSFORMER OPERATION c O MOVE BLACK WIRES FROM TERMINAL 3 TO p, a 1 I LLS I VMR TERMINAL 2 ON TRANSFORMER. s„ r_ 3.FOR DIFFERENT THAN FACTORY SPEED TAP. IIC © ALS RS CHANGE COOLING SPEED AT MOTOR T3 AND _ E , T4 TERMINALS.CHANGE HEATING SPEED AT • • MOTOR Ti.T2,AND T5 TERMINALS THERMOSTAT++ c o O FIELD WIRING PS I COOLING SPEED(YELLOW WIRE) 0 ECON ® T3-LOW SPEED NO ECONOMIZER m o T4-HIGH SPEED O9 00O 0 0 .p. • J�ATING SPEED(WIRE WIRE) mU• —Wry— — W > v L g LPS HPS 161Tt-LOW SPEED(070) 0� —GR— — G 3 • I T2-MED.SPEED —RD— — R a• T5-HIGH SPEED(140) ail o E — — • 4.ACCESSORY ECONOMIZER PLUG ADJACENT Ix —YL — — y ii o TO BLOWER HOUSING IN RETURN AIR r •©i COMPARTMENT.REMOVE MALE PLUG AND 0 o 1. 1 ® ® qi- —O� NOTPE • 4 ©©° ATCESSOE .FEMALE PLUG TO ECONOMIZER O —BL — — C o 0 �— J T61 5.USE COPPER CONDUCTORS ONLY. °- v TO THERMOSTAT ++USE NEC CLASS 2 WIRE. TB1 STAT 'a LL TERMINAL BLOCK++ 6.L1 AND L2 ON ICC CONTROL IS 24V INPUT. 7.SPEED TAP TERMINATIONS SHOWN ON WITH ECONOMIZER OPTION aa, c DIAGRAM ARE REPRESENTATIVE,BUT c INSTALLER/SERVICEMAN ACTUAL FACTORY SETTINGS MAY BE —VVry— —W g v THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO DIFFERENT BASED ON THE HEATING VALUE 5 a OF THE UNIT. G —GR— —G TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS: 8.FOR LOW STAGE OPERATION ONLY,REMOVE R —RD— —R g, STATUS LIGHT EQUIP.STATUS CHECK WHITE JUMPER.FOR 2 STAGE OPERATION, —YL — —Y r E ON NORMAL OPERATION REMOVE JUMPER AND CONNECT W2 TO W2 ON THERMOSTAT. 0 g a. NO POWER OR CHECK INPUT POWER SEE UNIT RATING PLATE FOR TYPE AND SIZE OF -c .. OFF INTERNAL CONTROL CHECK FUSE ON CONTROL OVER CURRENT PROTECTION OC— —BL — —C 2 0 FAULT REPLACE CONTROL JUNCTION EQUIPMENT IGNITION FAILURE GAS FLOW I�J OR GAS PRESSURE TERMINAL-- GROUND TB1 STAT OPEN ROLLOUT GAS VALVE INTERNAL TO FIELD GROUND v 0 1 BLINK SWITCH FLAME SENSOR INTEGRATED— 2 STAGE COOLING Z OR FLAME ROLLOUT CONTROL FIELD SPLICE .a, OPEN AUX.LIMIT BAD SWITCH PLUG �/ —Wry— —W SWITCH AUX.LIMIT OPEN CONNECTION m SWITCH(TEMP) G —GR— —G CC 2 BLINKS PRESSURE SWITCH CHECK SWITCa —RD— —R H(PRESS.)' OPEN PRESSURE SWITCH IGNITER -um". 3 BLINKS PRESSURE SWITCH CLOSED CHECK OVERCURRENT —YL — —Y1 WITHOUT INDUCER ON PRESSURE SWITCH PROT.DEVICE-� 4 BLINKS OPEN LIMIT SWITCH MAIN LIMIT OPEN 0- —PK— —Y2 BAD SWITCH :�•• • Q-- —BL — —C 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE 5� -• �.l COMPRESSOR 3 MIN.COMP. 6 BLINKS OUTPUT DELAY ANTI-CYCLE TIMER '.. 1 TB1 STAT '�' s oD I. Sc 230/3/60 0140L05415-A a .3 T.-, E aoc 2o�° u ,,,, a ob .. O v a, a, Y E m 3 2 44 www.daikinac.com SS-DSG3 �___ _ WIRING DIAGRAM—DSG0360453B*THREE PHASE 208/230V/60HZ BELT DRIVE a YL o RD u RD o BK o pU 9 To. GND BL �� • YL COMP r BL C ® a I- _B, PU ` g_L POWER SUPPLY X BR BK . , SEENOTE40 BK SEE NOTE 4 4111 1 BK 3 o v _ _ -_ RP RD BK a o BK • a BK • i� C 208 240T • II BL J 2 24 c o 2aV /R\ VMR � v RD WH I RD BBL GR ` BC OR P-r 0 � a BK BK.. , — 6 8 on m o U ' n . C a .11' RD '- v TB1 a OR ® • ® OR Ii r G__.ALS BL OR BOON IIC �_ PURe I D R— c v :____, —RC D 1 WO o a BL ®®®. YL a PU P m®®• YL WHI & '- YL YL YL YL o N., NOTE 2 RD I > m PLF o 13 rGR 2 O ,C?�RD - e —ocy® occt WII ��// BR BR Z II ® YL BR BL RD —RC z YL SEE YL/PK Z —PU I BL�� 6-- NOTE CC PU DL-11_ a_1I Q VV.R. (ALT.)HONEYWELL I i' 7 GAS VALVE GAS VALVE RD WH GR BL� I E=)--GR--F • PU MV PEL �L �R g _' GP GV • BL MV S1S2Y2Y1 C R W1 W2 GI — BL U I I I I I I LPS WH a o .� SMOKE/FIRE I I I I I I ® DETECTOR REPLACES TO THERMOSTAT t 2 re JUMPER WIRE t-I- • FSD o m ® OR —BL/PK HPS v ;3. E BK S a N m BR RC � , L v E )FC SS-DSG3 www.daikinac.com 45 WIRING DIAGRAM—DSG03604538*THREE PHASE 208/230V/60HZ BELT DRIVE(coNT.) L1 SUPPLY VOLTAGE L2 L3 COMPONENT LEGEND FACTORY WRING 208-240/3/60 ALS AUXILIARY LIMIT SWITCH BC BLOWER CONTACTOR LINE VOLTAGE COMP COMPRESSOR LOW VOLTAGE T2 C CM CONDENSER MOTOR OPTIONAL C Ti ` Q'- I oh C CONTACTOR HIGH VOLTAGE ID SI EM EVAPORATOR MOTOR • 111 i • F FUSE FIELD WRING T3 C FC FANCAPACITOR —=_ HIGH VOLTAGE FC ® IN FS FLAME SENSOR LOW VOLTAGE BC• GND EQUIPMENT GROUND WIRE CODE 13F ,, i GV GAS VALVE 1 �MO 1 C. IBR INDOOR BLOWER RELAY BL BLUE BLACKHPS HIGH PRESSURE SWITCH BK - IIC INTEGRATED IGNITION CONTROL BR BROWN L© J VMR IOW IGN IGNITOR GR GREEN O Q LPS LOW PRESSURE SWITCH OR ORANGE r LS LIMIT SWITCH PK PINK NOTE 3 TR - NOTE 3 PLF FEMALE PLUG/CONNECTOR PU PURPLE v y Q PS PRESSURE SWITCH RD RED o v O IGN RS ROLLOUT SWITCH WH WHITE °'-O FS• FS BC IIC TB1 TERMINAL BLOCK(24V SIGNAL) YL YELLOW v 8 F ©� ••• TR TRANSFORMER BL/PK BLUE WITH PINK STRIP I VM VENT MOTOR o D1 • VMR VENT MOTOR RELAY YL/PK YELLOW WITH PINK STRIP S 4 VMR 72 3 I O I c Ls THERMOSTAT NOTES ler FIELD WIRING tt .,L+ a ALS RS NO ECONOMIZER F. I IIC on 00 © I •®• 1.REPLACEMENT WIRE MUST BE THE SAME W Q SIZE AND TYPE OF INSULATION AS ORIGINAL , ,'8- PS I (USE COPPER CONDUCTOR ONLY). O� GR G 2 Y 0 c)r~J 2.ACCESSORY ECONOMIZER PLUG ADJACENT © —RD— — R 3 00ECON ©I • TO BLOWER HOUSING IN RETURN AIR ° 2' I 0 1 .0. • COMPARTMENT.REMOVE MALE PLUG AND YL Y o° 0- ATTACH FEMALE PLUG TO THE ECONOMIZER U N L _ ACCESSORY. Q -BL — — C . LPS HPS 3.L1 AND L2 ON IIC CONTROL IS 24V INPUT. I3i 3 o 8 4.USE COPPER CONDUCTORS ONLY. 2 O©� tt USE NEC CLASS 2 WIRE. TB1 STAT o E 0J 0 rG PLF ©©Q 5.FOR 208 VOLT TRANSFORMER OPER ION, WITH ECONOMIZER OPTION ® tI Yt © © MOVE BLACK WIRE FROM TERMINAL S TO 4� L ® _ L J NOTE 2 TERMINAL02 ON TRANSFORMER. Qi -WH —W 5 B TO THERMOSTAT 0 '— a v GR— —G _ TERMINAL BLOCKtt C• _RD— —R LL INSTALLER/SERVICEMAN SEE UNIT RATING PLATE FOR TYPE AND SIZE Ns — YL— —Y v THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO OF OVER CURRENT PROTECTION 'L3" TROUBLESHOOTING THIS APPLIANCE.STATUS LIGHT CODES ARE AS FOLLOWS: ® EL — _C Q Q STATUS LIGHT EQUIP.STATUS CHECK � ON NORMAL OPERATION - TB1 STAT off' NO POWER OR CHECK INPUT POWER E OFF INTERNAL CONTROL CHECK FUSE ONCONTROL 2 STAGE COOLING v REPLACE CONTROL - t IGNITION FAILURE GAS FLOW O♦ R— —G = GAS PRESSURE OPEN ROLLOUT GAS VALVE —RD— —R 1 BLINK SWITCH FLAME SENSOR OPEN AUX.LIMIT FLAME ROLLOUT �Ij♦ —YL — —Y1 CD SWITCH BAD SWITCH Z AUX.LIMIT OPEN0 —PK— —Y2 2 BLINKS' PRESSURE SWITCH OPEN CHECK PRESSURE SWITCH I,yti. 1 _BL _ —CCC 3 BLINKS PRESSURE SWITCH CLOSED CHECK `Q WITHOUT INDUCER ON PRESSURE SWITCH T B 1 STAT S 4 BLINKS OPEN LIMIT SWITCH MAIN LIMIT OPEN • BAD SWITCH y ..,. / 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE `\ 6 BLINKS COMPRESSOR 3 MIN.COMP. 208-240/3/60 0140L05405-A OUTPUT DELAY ANTI-CYCLE TIMER ab 3 y s Q p N C `5 6. O m C O a+ s N L E N 3 N Y i 0 0 m C 3E3 46 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG(036/048/060)09038*,DSG04811538*,DSG06014038*THREE PHASE 208/230V BELT DRIVE 1 1 a Y L '~ O RD RD _ [Ln BK 0 C PU O GND N GTO% ij BK 4* * T3 T O BL 0 YL • COMP 1 410 CL L3 BL MBK . E . •U ` -� POWER SUPPLY \♦ 0 BR BK 208-240/3/60 ♦� BK SEE NOTE 4 BK L o v BK =3 RD Ra o ll BK el ' >U 0 0 AC 20 240 BL o BK 1 VMR _ o 24V( L v RD WH ci I RD B GR •= m = fil BC GR PI IL ± - Z-• 0 v BK e • e BKJ — m U = 5_ RD e . ® RD v c: m •R ® ® OR b E OR °1 ° BL � o IC+.OR v - 0 9 q -core IIC ..2_ v PU II'—RD RD R OR -RI D OEC o v BL ••00 YL G n PU IN YL I — PU D••Q YL -. YL WH I i� ,- YL YL 43 YL NOTE 2 RD v PLFGR- i BL � � 11111 ? RG1 000Q BR Ir- CO BR RD -RD [ 1 Z YL BL_K , �[-, SEE YL/PK Z —PU - NOTE 3CC BL—, 3 o[_� PU W.R. (ALT.)HONEYWELL I—' _ GAS VALVE GAS VALVE WH GR BL r..[ ] -'�R�GR / D PU •SMV PK,PU IL BL I �R IBL -� C. • GV I BR \ • BL • MV V IS1 S2Y2Y1 C R W1 W2 G WH BR BL I U I I I I LPS , IIIw`, I a F •3 0 TO THERMOSTAT SMOKE/FIRE SEE NOTE 6 — DETECTOR tt • 00 0 REPLACES FS�RD 'o a JUMPER WIREt(1 HPS 2 0o ® 0,, —BL/PK _ .. v eK • v v -ao 0 O BREl::) RB .- w .. FC § "- S SS-DSG3 www.daikinac.com 47 WIRING DIAGRAM—DSG(036/048/060)0903B*,DSG0481153B*,DSG0601403B*THREE PHASE 208/230V BELT DRIVE(CONT.) 4 8 L1 SUPPLY VOLTAGE L2 L3 COMPONENT LEGEND 208-240/3/60 ALS AUXILIARY LIMIT SWITCH FACTORY WIRING BC BLOWER CONTACTOR LINE VOLTAGE COMP COMPRESSOR LOW VOLTAGE T2 C CM CONDENSER MOTOR ••• OPTIONAL - C T1cc��,, f * C CONTACTOR HIGH VOLTAGE ii W0 EM EVAPORATOR MOTOR F FUSE FIELD WIRING T3 C FC FAN CAPACITOR •••••••••III C FC FS FLAME SENSOR ___ HOW VOLTAGE BC _ GND EQUIPMENT GROUND BC •i • GV GAS VALVE WIRE CODE MI) BC HPS HIGH PRESSURE SWITCH BK BLACK IBR INDOOR BLOWER RELAY BL BLUE IIC INTEGRATED IGNITION CONTROL • IGN IGNITOR BR BROWN 2H L— VMR LPS LOW PRESSURE SWITCH GR GREEN _ LS LIMIT SWITCH OR ORANGE I— PK PINK NOTE 3 PLF FEMALE PLUG/CONNECTOR a, NOTE 3 pS PRESSURE SWITCH PU PURPLE o w L 0 I IGN © RS ROLLOUT SWITCH RD RED a-o F FS FS BC IIC TB1 TERMINAL BLOCK(24V SIGNAL) WH WHITE v o H C (Yo TR TRANSFORMER YL YELLOW . (''�j^'� ''�//``----'' VM VENT MOTOR BL/PK BLUE WITH PINK STRIP ?_ D1Q `--'V`--' • VMR VENT MOTOR RELAY YUPK YELLOW WITH PINK STRIP 4 VMR m O I o LS THERMOSTAT 'E o FIELD WIRING -f-f- s a ALS RS NOTES IIC © 000 NO ECONOMIZER no % 1.REPLACEMENT WIRE MUST BE THE SAME ©� _ _ _ _ `0 SIZE AND TYPE OF INSULATION AS ORIGINAL. wH W PS I • (USE COPPER CONDUCTOR ONLY). Q —GR— — G " -O ECON 0 • 2.ACCESSORY ECONOMIZER PLUG ADJACENT - —RD— — R 'c S 9 T �, TO BLOWER HOUSING IN RETURN AIR Il —YL — — Y o Q Q0 Q' 0- .0. • COMPARTMENT.REMOVE MALE PLUG AND m Q ATTACH FEMALE PLUG TO THE u N L _ — — ECONOMIZER ACCESSORY. O —BL — — C E. 3 LPS HPS ��®O 3.L1 AND L2 ON IIC CONTROL IS 24V INPUT. c`0i �v 4.USE COPPER CONDUCTORS ONLY. v 3 Al 5 4 tt USE NEC CLASS 2 WIRE. TB1 STAT o E — v o rO ® © ®� @ ,?_..,, 3 2 1 5.FOR 208 VOLT TRANSFORMER OPER ION, WITH ECONOMIZER OPTION o L PLF MOVE BLACK WIRE FROM TERMINALS TO —WH_ _W O NOTE 2 TERMINAL®ON TRANSFORMER. TO THERMOSTAT Q -GR— —G a v TERMINAL BLOCK tt 6.FOR LOW STAGE OPERATION ONLY,REMOVE Q —RD— —R m 'LL WHITE JUMPER.FOR 2 STAGE OPERATION, INSTALLER/SERVICEMAN REMOVE JUMPER AND CONNECT W2 TO W2 6 —YL — —Y ON THERMOSTAT. �y, c THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO �L TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS: o v Q -BL— —C ,, a o STATUS LIGHT EQUIP.STATUS CHECK 9 ON NORMAL OPERATION - SEE UNIT RATING PLATE FOR TYPE AND SIZE TB1 STAT - CHECK INPUT POWER E OFF NO POWER OR CHECK FUSE ON CONTROL OF OVER CURRENT PROTECTION 2 STAGE COOLING v INTERNAL CONTROL REPLACE CONTROL _ .� IGNITION FAILURE GAS FLOW —WH —W = o GAS PRESSURE 0— —GR— —G OPEN ROLLOUT GAS VALVE —FLAME SENSOR RD— —R 1 BLINK SWITCHHFLAME ROLLOUT —YL — —Y1 C7 OPEN AUX.LIMIT BAD SWITCH z SWITCH AUX.LIMIT OPEN —PK Y2 PRESSURE SWITCH CHECK Cr 2 BLINKS OPEN PRESSURE SWITCHLi —BL— —C CC 3 BLINKS PRESSURE SWITCH CLOSED CHECK r�. 7 . WITHOUT INDUCER ON PRESSURE SWITCH jT TEl STAT 4 BLINKS OPEN LIMIT SWITCH MAIN LIMIT OPEN -. 1 BAD SWITCH 5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE ' I I 6 BLINKS COMPRESSOR 3 MIN.COMP. 208-240/3/60 0140L05401-A OUTPUT DELAY ANTI-CYCLE TIMER Zr Q 1 E u E.F. c C i 6 s � O V -0 O O m 7 li C u .�O L E N N .L, O 40" O C y 3 m c 48 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG03604548*THREE PHASE 460V/60HZ BELT DRIVE a YL O v RD RD o BK 0 C . PU Q GND eV% I] BK . ® I O BL _� YL • COMP I 4* C IE5 4.0 BL •••••••••=4 MBK \ �R POWER SUPPLY PU Y\ 460/3/60 • BR BK I BK 575/3/60 —SEE NOTE 4 3 m RD ° =III K :KOR Oo Iii O 3 ® ] BL 2• . 46475 72 2460 C TR ni 575 TR 2400 VMR o 24V RD 1111 I RD BL GRBC GR PKIL [_jDwH �s J = 0 ww o BK IS r — J 7 6 BKS I 00 0. v RD telli RD' ` v 6 v OR 6 a61 •R� BR ° v PK� „ o OR BL �OR� o 0 141 q ECON LL PU —RD RD R_ c c o N BR RD DONJ LTG— ° v BL VSZEI - o v PU YL—I PU ©©O© 'YL it > YL WH A F • YL YL ill i ,`,^, ARD I YL NOTE 2 PLF GR .4) H reao R— c,G3—RD NI PU Q• o[ �WH CD -4 BL I[ 3—BR IIC Z OR RD---p SEE YL/PK YL BL.t [ z CC Q YL m[= NOTE 3 PU BL�[r[ o[-• W.R. (ALT.)HONEYWELL—�BL BL GR IC"[ s GRR�� GAS VALVE GAS VALVE PK PU PU WH EL r� [ �[- rGR a •us PU •MV BR BL RD YL GRI BL o[_[ GV • BL • MVv Si S2 Y2 C R Y1 W1 G >.' �, BLiH1 LPS Q o w [ [ [ [ [ [4 v BK v TO THERMOSTAT++ =G `9 o FOR • i SMOKE/FIRE :- = c ti DETECTOR JUMPER HPS _ RD —BL/PK '2 :3 0 • MEE OR ,-- BK • ❑c-' o c t ,. BR a O RDS § E g FC SS-DSG3 www.daikinac.com 49 WIRING DIAGRAM—DSG03604548*THREE PHASE 460V/60HZ BELT DRIVE(coNT.) L1 SUPPLY VOLTAGE L2 L3 COMPONENT LEGEND FACTORY 460-575/3/60 WIRING T2 C ALS AUXILLARY LIMIT SWITCH C Ti �'- I W BC BLOWER CONTACTOR LINE VOLTAGE 4 4 Il W,,� I COMP COMPRESSOR LOWVOLTAGE ��� 1 • ) CM CONDENSER MOTOR OPTIONAL HIGH FC X11 T3 C , C CONTACTOR - VOLTAGE —_ _ y EM EVAPORATOR MOTOR OPTIONAL LOW F FUSE BC VOLTAGE FC FAN CAPACITOR BC r, _gCI . FS FLAME SENSOR ` VM' GND EQUIPMENT GROUND FIELD WIRING L� ® � GV GAS VALVE HIGH VOLTAGE HPS HIGH PRESSURE SWITCH �� RI III IBR INDOOR BLOWER RELAY —__ LOW VOLTAGE (�►i •: IIC INTEGRATED IGNITION CONTROL WIRE CODE \. IGN IGNITOR BK BLACK ♦\ LPS LOW PRESSURE SWITCH aiMIll T LS LIMIT SWITCH BL BLUE r PLF FEMALE PLUG/CONNECTOR BR BROWN v I NOTE 3 NOTE 3 PS PRESSURE SWITCH GR GREEN o v L 0 © RS ROLLOUT SWITCH OR ORANGE v o IGN BC IIC TEl TERMINAL BLOCK(24V SIGNAL) PK PINK a > F ©O FSD FS •411111 •• TR TRANSFORMER PU PURPLE VM VENT MOTOR RD RED P D1 O �o • VMR VENT MOTOR RELAY WH WHITE 4 VMR YL YELLOW E II LS = c O I O BUPK BLUE WITH PINK STRIP c YL/PK YELLOW WITH PINK STRIP Y a ALS • RS NOTES 6 m IIC • • • • 1 .REPLACEMENT WIRE MUST BE FIELD WIRINGRMOSTATm = E • TH 6 THE SAME SIZE AND TYPE OF =°v PS INSULATION AS ORIGINAL. NO ECONOMIZER c .Z ® • (USE COPPER CONDUCTOR ONLY). v ECON ©� —MIG H_ — W m o 09 07 0 <3 <3 I 2.ACCESSORY ECONOMIZER PLUG Q —GR— — G ADJACENT TO BLOWER HOUSING •O• • IN RETURN AIR COMPARTMENT. 0 —RD— — R .i" Q1 1 L — — — LPS HPS REMOVE MALE PLUG AND ATTACH 3.1 —YL — — Y FEMALE PLUG TO THE ECONOMIZER �L S ACCESSORY. �L E 063.L1 AND L2 ON IIC CONTROL IS 24V INPUT. Q —EL — — Cal S r '(D en 4.USE COPPER CONDUCTORS ONLY. v ® G ® Y �S1 C PLF L _ _ Q OJ �Q ++USE NEC CLASS 2 WIRE. TB1 STAT TO THERMOSTAT++ I SEE eL EJ WITH ECONOMIZER OPTION TERMINAL BLOCK NOTE 2 SEE UNIT RATING PLATE FOR TYPE AND m= m SIZE OF OVER CURRENT PROTECTION. b -WH— —W INSTALLER/SERVICEMAN C:' c —GR— —GTHE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO 3 5 TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS: JUNCTION EQUIPMENT —RD— —R TERMINAL 4 GROUND —Yl — —Y o v STATUS LIGHT EQUIP.STATUS CHECK INTERNAL TO FIELD GROUND = �'o ON NORMAL OPERATION - INTEGRATED— �.a.. — .e E OFF NO POWER OR CHECK INPUT POWER CONTROL V INTERNAL CONTROL CHECK FUSE ON CONTROL FIELD SPLICE —BLC U REPLACE CONTROL PLUG m r 1 BLINK IGNITION FAILURE GAS FLOW CONNECTION SWITCH(TEMP)°T�° TEl STAT = o OPEN ROLLOUT GAS PRESSURE GAS VALVE SWITCH(PRESS.) IGNITER "MY 2 STAGE COOLING SWITCH FLAME SENSOR OVERCURRENT$ �2 —WH— —W kp FLAME ROLLOUT PROT.DEVICE OPEN AUX.LIMIT BAD SWITCH o♦ —GR— —G ? _ SWITCH AUX.LIMIT OPEN Z 2 BLINKS PRESSURE SWITCH CHECK 0' —RD— —R CC OPEN PRESSURE SWITCH al —YL — —Y1 3 BLINKS PRESSURE SWITCH CLOSED CHECK I,yI'. . F" q —PK— —Y2 _ WITHOUT INDUCER ON PRESSURE SWITCH • 4 BLINKS OPEN LIMIT SWITCH MAIN LIMIT OPEN —BL — —C BAD SWITCH <5 BLINKS FALSE FLAME SENSED STICKING GAS VALVE • TEl STAT 6 BLINKS COMPRESSOR 3 MIN.COMP. , I „ OUTPUT DELAY ANTI-CYCLE TIMER 460-575/3/60 0140L05407-A LS m 3 'J :E Tt 0 3 g E 1% m c , -o s9 o :.,q', L O ao G + v °� , N v m Y N O m o c E c 3 50 www.daikinac.com SS-DSG3 WIRING DIAGRAM—DSG(036/060)090(45/78),DSG0480904B,DSG048115(48/78),DSG060140(48/78)THREE PHASE 460V/575V BELT DRIVE • a YL O RD RD Ln BK O PU GND a AAD BK T1 T3 I O BL YL . COMP I 40 C © 3 BL 1 MBK I �= POWER SUPPLY 'U 460/3/60 • • BR BK BK 575/3/60 SEE NOTE v -P I 3 m RD o v GI7- K K� priB •- ° o ^ O 460/575 � .• Et 460 TR C 2 4V s. TR • •• BL _ 575 240 VMR RD RD WH _ u RD BL GR BC GRPK IL 1 .= .= 0 - > e `o 2 BK EKE _ o v RD a : RD v v OR 10 `.. ORIII. 2_ o o OR S o OR" 0 o BL v CJ ECON L PU RD D R^ RD DOC — a BL •••8 c PU YL—I PU - ®®• —YL - - YL WH E • YL - YL 'g YL NOTE2 �R• I V PLF 7 OR 0�� = o C RDS I EL- 3-1 WH lJ 13R—�; 00 O7 YL RD ill IIC tDZ YL SEE YL/PK —PU - EL�� ��- NOTE 3 13 BL—( 3 oc• PU W.R. (ALT.)HONEYWELL ���3 m_ CC GAS VALVE GAS VALVE WH I EL r qC-�R�GR • PU �MV PUYLELRD GR BL ¢�-� . • GV ' I I BI I I • - BK • BL MV P1S2 Y2 Y1 C R W1 W2 G I ° aB H BL U I I I I Wei I �4 LPS a ,; BR I I I I I t SMOKE/FIRE DETECTOR SEE o m 7 REPLACES JUMPER WIRE TO THERMOSTAT • o NOTE 5 IFS IRD 1 HPS ° m ® Of, —BL/PK v .� 6' . - v o • BR• .(0 R• m E' FC SS-DSG3 www.daikinac.com 51 WIRING DIAGRAM—DSG(036/060)090(48/78),D5G04809048,DSG048115(48/78),DSG060140(48/78)THREE PHASE 460V/575V BELT DRIVE(coNT) L1 SUPPLY VOLTAGE L2 L3 COMPONENT LEGEND 460-575/3/60 T2 C ALS AUXILLARY LIMIT SWITCH FACTORY WIRING C Ti I W BC BLOWER CONTACTOR LINE VOLTAGE �� � '�, 0 I t COMP COMPRESSOR LOW VOLTAGE T3 C CM CONDENSER MOTOR •�� OPTIONAL HIGH FC C CONTACTOR VOLTAGE EM EVAPORATOR MOTOR - - - BC F FUSE FIELD WIRING BC FC FAN CAPACITOR ® BC FS FLAME SENSOR __ HIGH VOLTAGE VIo1' GND EQUIPMENT GROUND LOW VOLTAGE . 0 O GV GAS VALVE WIRE CODE L— J ■ HPS HIGH PRESSURE SWITCH BK BLACK RD IBR INDOOR BLOWER RELAY BL BLUE IIIIIIII"I•j IIC INTEGRATED IGNITION CONTROL BR BROWN IGN IGNITOR GR GREEN Q LPS LOW PRESSURE SWITCH OR ORANGE LS LIMIT SWITCH PK PINK I- TR PLF FEMALE PLUG/CONNECTOR E Y 1 NOTE 3 NOTE 3 PS PRESSURE SWITCH PU PURPLE o v L IGN © RS ROLLOUT SWITCH RD RED a-o IIC WH WHITE a, $ BC TB1 TERMINAL BLOCK(24V SIGNAL) F FS Q-- FSYL YELLOW a,- i TR TRANSFORMER i H C BL/PK BLUE WITH PINK STRIP 3 c VM VENT MOTOR - D1 O CQo • VMR VENT MOTOR RELAY YL/PK YELLOW WITH PINK STRIF � 4 LS VMR THERMOSTAT 2 o O NOTES FIELD WIRING tt -' a IIC I • ALS• •RS •®• NO ECONOMIZER o0 to 1.REPLACEMENT WIRE MUST BE THE SAME ©7 —WH— — W E • SIZE AND TYPE OF INSULATION AS ORIGINAL. -,3 PS I (USE COPPER CONDUCTOR ONLY). ©J OR G c 0 _OJ 2.ACCESSORY ECONOMIZER PLUG ADJACENT GJrA —RD— — R t v ECM • TO BLOWER HOUSING IN RETURN AIR 67 —YL — — y � a 0 C> OO ® ® 00. • COMPARTMENT.REMOVE ATTACH FEMALE PLUG TO MALE THE ECONOMIZERPLUG c a AND C w i L — — ACCESSORY. —BL— — C N LPS HPS 3.L1 AND IIC CONTROL IS 24V INPUT. O©O 4.USE COPPER CONDUCTORS ONLY. STAT a E ©5 O tt USE NEC CLASS 2 WIRE. TB1 a, o WITH ECONOMIZER OPTION o r , PLF 3O0 Q 5.FOR LOW STAGE OPERATION ONLY,REMOVE m v G Y1 F`Y2 © NOTE2 WHITE JUMPER.FOR 2 STAGE OPERATION, _WH_ _ o o L ® ® O IL JREMOVE JUMPER AND CONNECT W2 TO W2 �' W 22 TO THERMOSTAT ON THERMOSTAT. ei —GR— —G = ,1 TERMINAL BLOCKtt Q -RD— —R LL INSTALLER/SERVICEMAN IiS — YL— —Y c c ai THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO 3 d TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS: Q —BL— —C o a a STATUS LIGHT EQUIP.STATUS CHECK � �, ON NORMAL OPERATION SEE UNIT RATING PLATE FOR TYPE AND SIZE TB1 STAT E NO POWER OR CHECK INPUT POWER OF OVER CURRENT PROTECTION. v OFF INTERNAL CONTROL CHECK FUSE ON CONTROL 2 STAGE COOLING REPLACE CONTROL - IGNITION FAILURE GAS FLOW © WH W GAS PRESSURE © —GR— —0 OPEN ROLLOUT GAS VALVE O 1 BLINK SWITCH FLAME SENSOR —RD— —RCD FLAME ROLLOUT 6( —YL — —Y1 OPEN AUX.LIMIT BAD SWITCH z SWITCH _ AUX.LIMIT OPEN 0, —PK— —Y2 PRESSURE SWITCH CHECK —BL — —c CC 2 BLINKS OPEN PRESSURE SWITCH 'F 4•' O 38LINKS PRESSURE SWITCH CLOSED CHECK .111;1r.40:—..rWITHOUT INDUCER ON PRESSURE SWITCH ,r KTB1 STAT 4 BLINKS OPEN LIMIT SWITCH MAIN LIMIT OPEN • � FALSE FLAME BAD SWITCH j L / 5 BLINKS SENSED STICKING GAS VALVE 7f� \ 6 BLINKS COMPRESSOR 3 MIN.COMP. OUTPUT DELAY ANTI-CYCLE TIMER 460-575/3/60 0140L05402-A v go Q o .� g E Y f00 L top r " v a S2 m -c', 3. 3 E c v a, Y ° o m 2 c 52 www.daikinac.com SS-DSG3 k i WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLS ARE LOCATED IN SUPPLEMENT IODS1024* FOR COMPLETE INFORMATION AND INSTALLATION INSTRUCTIONS FOR MODELS WITH DDC CONTROLS, SEE MANUAL DK-DDC-TG D-01* 5S-DSG3 www.daikinac.com 53 ACCESSORIES DAIKIN MASTER DESCRIPTION FITS MODEL FIELD- FACTORY- OPERATING ITEM# SIZES INSTALLED INSTALLED WEIGHT(IBS) Curb 14CURB3672B 14" Roof Curb 3-5 Tons V 86 18CURB3672B 18" Roof Curb 3-5 Tons V 100 24CURB3672B 24" Roof Curb 3-5 Tons V 128 GHRC-3672 Hurricane Restraint Clips 3-5 Tons V _ 2 Ultra Low-Leak Economizer&Power Exhaust' 1036609C Ultra Low-Leak Downflow Economizer w/Enthalpy 3-5 Tons V _ V 71 _ 1039609 Ultra Low-Leak Horizontal Economizer w/Enthalpy 3-5 Tons V _ 71 104650921 Prop Power Exhaust 230v 3-5 Tons V 55 104650931 Prop Power Exhaust 460v 3-5 Tons V 55 104650941 Prop Power Exhaust 575v 3-5 Tons V 55 Low-Leak Economizer&Power Exhaust2 DDNECNJ3672C Low-Leak Downflow Economizer 3-5 Tons V V 82 DPE36722 Downflow Power Exhaust(208/230 Volt) 3-5 Tons V 55 DPE36724 Downflow Power Exhaust(460 Volt) 3-5 Tons V _ 55 DPE36727 Downflow Power Exhaust(575v) 3-5 Tons V 55 DINHZ3672B Horizontal Economizer, Internally Mounted 3-5 Tons V90 DHZECNJ3672 Horizontal Economizer 3-5 Tons V 70 DHPE36722 Horizontal Power Exhaust(208/230 Volt) 3-5 Tons V _ 55 DHPE36724 Horizontal Power Exhaust(460 Volt) 3-5 Tons V 55 DHPE36727 Horizontal Power Exhaust(575 Volt) 3-5 Tons V 55 Downflow Accessories D25FD3672 25% Manual Fresh Air Damper 3-5 Tons V 12 D25MFD3672 25%Motorized Fresh Air Damper 3-5 Tons V 16 DDNBBS3672 Burglar Bar Sleeves with Supply&Return 3-5 Tons V 30 DDNECNJ3672NR Downflow Economizer2 w/o Barometric Relief 3-5 Tons V 77 DDNSQRD3616 Downflow Square-to-Round Adapter(16" Round) 3 tons V 45 DDNSQRD487218 Downflow Square-to-Round Adapter(18" Round) 4-5 tons V 35 Horizontal Accessories DBRD3672 Barometric Relief Damper 3-5 Tons V 15 Concentrics CDK36 Concentric Duct Kit 3 Ton V 27 CDK36515 Flush Mount Concentric Duct Kit w/Filter 3 Ton V 28 CDK36530 Step Down Concentric Duct Kit 3 Ton V 27 CDK36535 Step Down Concentric Duct Kit w/Filter 3 Ton V 28 CDK4872 Concentric Duct Kit 4-5 Ton V 27 CDK4872515 Flush Mount Concentric Duct Kit w/Filter 4-5 Ton V 28 CDK4872530 Step Down Concentric Duct Kit 4-5 Ton V 27 CDK4872535 Step Down Concentric Duct Kit w/Filter 4-5 Ton V 28 54 www.daikinac.com SS-DSG3 __ ACCESSORIES(CONT. DAIKIN MASTER DESCRIPTION FITS MODEL FIELD- FACTORY- OPERATING ITEM# SIZES INSTALLED INSTALLED WEIGHT(LBS) DDC Accessories3 DDC communicating controller(built-in BACnet® MS/TP)includes Standard Room Sensor to be 3-5 Tons V 2 . installed in field 10366D09C DDC Ultra Low-Leak Downflow Economizer 3-5 Tons V V 71 10396D09 DDC Ultra Low-Leak Horizontal Economizer 3-5 Tons V 71 10465DDC Power Exhaust kit used with DDC Ultra Low-Leak 3-5 tons V 1 Economizer DLAKTO1 Low-Ambient 3-5 Tons V V 2 LONKTO1 LonWorks®card 3-5 Tons V 1 3PMK01 Phase Monitor(3-Phase Only) 3-5 Tons V V 2 DFSKTO1 Dirty Filter Switch 3-5 Tons V 1 High-Static Kits° HSKTS036 High Static Kit - 230v&460v DS*,3 Ton V V 2 HSKTSO48 High Static Kit - 230v&460v DS*,4 Ton V V 38 HSKTS060 High Static Kit - 230v&460v DS*,5 Ton V V 38 - HSKTS036-7 High Static Kit - 575v DS*,3 Ton V V 2 HSKTSO48-7 High Static Kit - 575v DS*,4 Ton V V 5 HSKTS060-7 High Static Kit - 575v DS*,5 Ton V V 38 Crankcase Heater Kits 0163R000025 40W 230V 3 tons V 1 0163R00031S 40W 460V 3tons V 1 0163R00032S 40W 575V 3 tons V 1 0130L00017S 70W 230V 4-5 tons V _ 1 0130L000185 70W 460V 4-5 tons V 1 0130L00019S 70W 575V 4-5 tons V 1 High Efficiency Filters 0160L00203 High Efficiency MERV 13 Air Filter Nom. 3 tons V 2 Size: 24x24x2; (Order Qty 1) 0160L00204 High Efficiency MERV 13 Air Filter Nom. 4 tons V 4 Size: 14x20x2; (Order Qty 4) 0160L00205 High Efficiency MERV 13 Air Filter Nom. 5 tons V 4 Size: 16x20x2; (Order Qty 4) Misc Accessories HAILGDO3D Condenser Coil Hail Guard 3-5 tons V 19 • Convenience Outlet: Non Powered 3-5 tons V 2 Convenience Outlet: Powered 3-5 tons V 42 Disconnect Switch 3-5 tons V 5 LAKT11 Low Ambient Kit, 208-230V-non-DDC 3-5 tons V V 14 LAKT13 Low Ambient Kit,460V-non-DDC 3-5 tons V V 14 LAKT14 Low Ambient Kit,575V-non-DDC 3-5 tons V V 14 3PMNDKO1 Phase Monitor-Non DDC 3-5 Ton V V 2 Smoke Detector(supply and/or return air) 3-5 Ton V 11 SS-DSG3 www.daikinac.com 55 ACCESSORIES(CONT.) 4 DAIKIN MASTER DESCRIPTION FITS MODEL FIELD- FACTORY- OPERATING ITEM# SIZES INSTALLED INSTALLED WEIGHT LBS) Hinged Panels 3-5 Ton V 10 FSKO1A Freeze Stat Kit 3-5 Ton V 1 IRKT-01 Isolation Relay Kit 3-5 Ton V 2 LPM-07 LP Conversion Kit(For DSG036045 unit only) 3 Ton V 1 LPM-06 LP Conversion Kit 3-5 Ton V 1 220-GX-01 Flue Extension Kit 3-5 Ton V 2 HA036300 High Altitude Kit 3-5 Ton V 2 1 Use Economizer&Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer&Power Exhaust listed within Low-Leak section 'For a full list of DDC accessories,please refer to DDC Controller Technical Guide manual(DK-DDC-TGD-01B) "HSKT High-Static Kits are for use with standard single-speed belt-drive units only. Note:Where multiple variations are available,the heaviest combination is listed. Our continuing commitment to quality products may mean a change in specifications without notice. ©2018 DAIKIN COMPANY,L.P. • Houston,Texas • Printed in the USA. 56 www.daikinac.com SS-DSG3