Permit (240) CITY OF TIGARD74 ELECTRICAL PERMIT
8. '' COMMUNITY DEVELOPMENT Permit#: ELC2018-00064
T(G AR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/09/2018
Parcel: 1 S 135AC04400
Jurisdiction: Tigard
Site address: 8920 SW OAK ST
Project: Oak Street Apartments Subdivision: ASHBROOK FARM Lot: 14
Project Description: Electrical for building B-92 unit apartment building.
Contractor: STEELE ELECTRIC LLC Owner: DBG OAK STREET LLC
716 ROXE DR 2164 SW PARK PL
FOREST GROVE, OR 97116 PORTLAND, OR 97205
PHONE: 503-332-1280 PHONE:
FAX: 503-372-6448
FEES
Quantity Description Date Amount
1369 sf Permit Fee-Elect(SF or 1st 07/09/2018 $202.46
Specifics: MF dwelling unit)
9212 Each Add'I Unit(Multi-Family) 07/09/2018 $9,211.93
Type of Use: MF 2 ea Services or Feeders-201 to 07/09/2018 $267.12
Class of Work: NEW 400 amps
Type of Const: 1 ea Services or Feeders-401 to 07/09/2018 $200.34
600 amps
Occupancy Grp: 74 crt Branch Circuits w/Purchase 07/09/2018 $549.08
Service or Feeder
1 ea Plan Review Electricial 07/09/2018 $2,607.73
1 ea 12%State Surcharge- 07/09/2018 $1,251.71
Electrical
1 ea Limited Energy 07/09/2018 $75.00
0 ea Plan Review Electricial 07/09/2018 $18.75
Total $14,393.12
Required Items and Reports(Conditions)
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through 952-001-0090. You ' ru y e es or •uestions to OUNC by calling 503.232. 00.332.2344.
Issued By: • '•nature:
OWNER INSTALLATION ONLY
The installation is being made on property I own which is not intended for sale,lease or rent.
OWNER'S SIGNATURE Date:
CONTRACTOR INSTALLATION ONLY
SIGNATURE OF SUPR.ELEC' Date:
LICENSE NO.
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
1
Electrical Permit Application FOR OFFICE ESE ONE)'
Received
City of Tigard R .� '� !)$ Date/B /,i ..7
Illt v 13125 SW Hall Blvd.,Tigard,OR 97223j
Plan Revie v - /PPM Related Permit#: /4
Phone: 503.718.2439 Fax: 503.598.196 r4 9 s, Date/B : .0" i` .•4 .
'/'' "'' ReadyDate/By: Jure El See Page 2 for
Inspection Line: 503.639.4175
TIGARD Notified/Method:`,�i 1, 61 Supplemental Information
Internet: www tigard or.gov .fi
4 . .,,. :t ... TYE Oli`tr i. fl( j I i_ , PLArl.REVIEW
tg New construction ❑Addition/alteration/replacement ;,7res( Please check all that apply(submit 2 sets of u w/items checked):
❑Service or feeder 400 amps or more Building over three stones.
0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards.
, CATEGORY OF.CONSTRUCTION , , , exceeds 10,000 amps at 150 volts or ❑Floating buildings.
❑ 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural
amps for all other installations. buildings.
14 Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION- ❑Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address:sq� Sfj pike. &- gam, ji IIP or more. ❑"A","E","1-2","1-3",
Six or more residential units. occupancy.
City/State/ZIP: h Ae p / d u 0 Health-care facilities. ❑Recreational vehicle parks.
Suite/bldg./apt.#: PrO Project name: ❑Hazardous locations. ❑Supply voltage for more than
j .f ' �,T2Ef T , 0.,—,,,,6,S ❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: t IEEE*SCHEDULE•
Description I Qty. I Each I Total I *
New residential single-or multi-family dwelling unit.
Subdivision: I Lot#: Includes attached garage.
1,000 sq.ft.or less ( 168.54 itsit,r,i 4
Tax map/parcel#: Ea.add'l 500 sq.ft.or portion ( 33.92 '13.4.-9( 1
DESCRIPTION OF WORK.
iX:Y1 /I(/I.T( FA-m. flplitr ' ^`f Limited energy,multi-family i w'� " -� 75.00 �� L.
} residential(with above sq.ft.)
—tit Renewable Energy 0 See Page 2
a ids''` 'PROPERTY OWNER 0 TENANT '-- Services or feeders installation,alteration,and/or reloc ttion
Name: 46 S ams 200 amps or less 100.70 2
201 amps to 400 amps 2..---- 133.56 Ni 1,14). 2
4• Address: 10 220 SW 6 126‘...70I3Vieb g D. ii f30 401 amps to 600 amps i 200.34 "I: 1 2
r City/State/ZIP: fORTLAlth, D!2 93 Z3 601 amps to 1,000 amps 301.04 2
i * Phone:(6p) ) Z..1.Z.- ve3 3 Fax:( ) Over 1,000 amps or volts , 552.26 2
s) . Temporary services or feeders installation,alteration,and/or
Email:\I1�Ad cK �gSpael0E. cd�Vt relocation
Owner I stallation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
401 amps to 599 amps 168.54 2
Owner signature: Date:
V — ,. Branch circuits-new,alteration or extension,per panel
APPLICANT „[ CONTACT PERSON A.Fee for branch circuits with
Business name: AA AA-70 5 above service or feeder fee, -74 7.42 `� 2
each branch circuit -1 °I
Contact name:CcAirata / AL. l B.Fee for branch circuits without
service or feeder fee,first 56.18 2
Address: ioZ?Cp .Svi 6> 0Byoh 2, Iv 53p branch circuit
City/State/ZIP: fbe A ve. 9PZZ,3
EachMiscellaneous addl h ircuit 7.42 2
(service or feeder not included)
Phone:(5 )132-- vz,33 I Fax: :( ) Each manufactured or modular 67.84 2
^�- dwelling,service and/or feeder
Email: ' M 4,VC R,a a L nc2s, conA- Reconnect only 67.84 2
NRACTOR "` Pump or irrigation circle 67.84 2
Business name: Cj+-4,4,kP S.\ -i Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy
0 See Page 2 2
Address: `7{6 ' ' '*w& panel,alteration,or extension.
Each additional inspection over allowable in any of the above
City/State/ZIP: .i ' `cks C -){t,-tz Additional inspection(1 hr min) 66.25/hr
Phone:(9.-;)7) 1 73 Z-1 1-Ty I Fax:( >)3 ) .V7 2.-(yl t t Investigation(1 hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email: ,..^ ( ( iN j"t-ek , C Inspections for which no fee is 90.00/hr
CCB Lit.: 1,t()i 4,e, I Electrical Lic.: vM.14N 1 Suprv.Lic.: 5-3 ct S specifically listed('A hr min)
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: - —_ Subtotal: i Li i 3c).
Date: LA 1 1� 0Plan Review Required(25%of permit fee): �t 6 0� 73
Print name: jState surcharge(12%of permit fee): ! 2 57. ?/
TOTAL PERMIT FEE: /
Authorized signature: ;),-1e, " 7
This permit application expires if a permit is not obtained within 180
Print name: Date: days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 4404615T(11/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
Feelforuall residential systems combined: $75.00 �y a.y .Snul E.. ,.
IAL WORK ONLY: FEE
Description on � Qty I Each I Total
3' Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed('V2 hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Subtotal(Enter on Page 1):
Fee for each commercial system: $75.00 * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
t:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015
City of Tigard
Tel: 503.718.2439
Location: Inspection Date:
8920 SW OAK ST, TIGARD, OR, 97223
Record Type: Record ID:
Commercial - Electrical ELC2018-00064
Inspection Type: Inspector:
199 Electrical final Jeff Grove
Result:
PASS - NoCofO
Comments:
Violation Summary:
Inspector Contractor