Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (102)
IA\L-lik RED HAWK FIRE PROTECTION, LLC 0 3801 Fruit Valley Rd. RECEIi Vave , WA 9 ncou(360) 984-371r 8660 Z JUN 13 2018 CITY OF TIGARD BUILDING DIVISION .„ 0 ER • PROVID SpR Nkk fifre/416�e CN Vitila/rCFLEx 2-1N D OB NEA RINGS , oV eRNTERP Ao-a1 O • FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR OREGON REPRODUCTIVE MEDICINE TIGARD, OR RHFP JOB NO. 240019 .. 1LI1c1Worldwide Fire Protection Contacts www.tyco-fire.com Products 0 Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers " Description described herein must be installed --- and maintained in compliance with The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National y Sprinklers described in this data sheet Fire Protection Association,in addition are quick response,standard coverage, to the standards ofany other authori- decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so .3 sprinklers designed for use in light or may impair the performance of these ti `' ordinary hazard,commercial occupan- devices. cies such as banks, hotels, and shop- The owner is responsible for main- ping malls. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- applicable, is intended for use in areas tor or product manufacturer with any with a finished ceiling. This recessed questions. T pendent sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed .i.`: ,,, Escutcheon with recessed adjust- Identification • ment up to 5/8 inch (15,9 mm)from `" the flush pendent position. Number (SIN) , • A two-piece Style 20 Recessed TY313 Upright 5.6K, 1/2"NPT Escutcheon with recessed adjust- TY323 Pendent 5.6K, 1/2"NPT ment up to 1/2 inch(12,7 mm)from the flush pendent position. Technical The adjustment provided by the Operation Recessed Escutcheon reduces the Data accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Intermediate level versions of Series Refer to Table A the rated temperature is reached, the fluTY-FRB Sprinklers are described in Maximum Working Pressure glassd bulb, sufficientlywih to shatter the Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) bulb, allowing the sprinkler to kler guards and shields are described 250 psi(17.2 bar)' activate and water to flow. in Technical Data Sheet TFP780. •The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria K=5.6 GPM/psi'/2(80,6 LPM/bar1/2) The TYCO Series TY-FRB,5.6 K-factor, Temperature Rating Upright (TY313) and Pendent (TY323) Refer to Table A Sprinklers are intended for fire protec- IMPORTANT Finishes tion systems designed in accordance Always refer to Technical Data Sprinkler: Refer to Table B with the standard installation rules "INSTALLER recognized by the applicable Listing or Sheet TFP700 for the WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA with respect to handling and instal- Plated 13, and FM Approval is based on the lation of sprinkler systems and com- ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention installation can permanently damage Frame Bronze Data Sheets).Only the Style 15 or Style a sprinkler system or its compo Button Brass/Copper 20 Recessed Escutcheon is to be used 0 nents and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. p Bulb Glass to operate in a fire situation or cause Compression Screw Bronze it to operate prematurely. Deflector Bronze Page 1 of 4 JULY 2017 TFP172 • TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 • 1 - Frame 4 Bulb indicated on Deflector. can be provided on special request. 2 Button 5 Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* ��..., 1 Tli:`FTb� ` 7�rlr1�Tj�1�1�� - -"=", (11,1 mm) r 5 n 7/16" . 1 \ �R=_ NOMINAL (50,8 mm) ��I c 4 t �l < i�IP W VIII wow , 2 ` 8° \O____07 1-3/8" GAJ 3 (50,8 mm) (34,9 mm) / WRENCH I FLATS } 1/2" NPT** DEFLECTOR* 1- 2-7/8"(73,0 mm)DIA. ---- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant e,,,,. applied to the pipe threads, hand- The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. (USE ONLY Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the END"A") dance with this section. sprinkler fitting using only the W-Type .,,,if1/11/".. 6 Sprinkler Wrench(Figure 2).With ref- FIGURE Instructions P � ( 9 FIGURE 2 Do not install any bulb-type sprinkler erence to Figure 1,apply the W-Type 6 • W-TYPE 6 if the bulb is cracked or there is a loss Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH of liquid from the bulb. With the sprin- Torque sprinklers 7 to 14 ft. lbs.(9,5 to kler held horizontally,a small air bubble 19,0 Nm). should be present.The diameter of the Recessed Pendent Sprinklers WRENCH air bubble is approximately 1/16 inch The Series TY-FRB Recessed Pendent RECESS (1,6 mm)for the 135°F(57°C) and 3/32 Sprinklers must be installed in accor- inch(2,4 mm)for the 286°F(141°C)tern- dance with the following instructions. OT perature ratings. Step A. After installing the Style 15 i A leak-tight 1/2 inch NPT sprinkler or Style 20 Mounting Plate over the joint should be obtained by applying a sprinkler threads,and with pipe-thread minimum to maximum torque of 7 to 14 sealant applied to the pipe threads, 1 . ft. lbs. (9,5 to 19,0 Nm). Higher levels hand-tighten the sprinkler into the \�� of torque can distort the sprinkler Inlet sprinkler fitting. with consequent leakage or impairment PUSH WRENCH of the sprinkler. Step B. Tighten the sprinkler into the INTO ENSURE sprinkler fitting using only the W-Type Do not attempt to compensate for 7 Recessed-Sprinkler Wrench (Figure ENGAGEMENT SPRINKLER insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WITH WRCHINN AREA eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 W-TYPE 7 RECESSED Upright and Pendent Sprinklers Nm). SPRINKLER WRENCH The Series TY-FRB Upright and Step C. After ceiling installation and Pendent Sprinklers must be installed finishing,slide on the Style 15 or Style in accordance with the following 20 Closure over the Series TY-FRB instructions. Sprinkler and push the Closure over the Step 1.Install Pendent sprinklers in the Mounting Plate until its flange comes in pendent position. Install upright sprin- contact with the ceiling. klers in the upright position. • TFP172 ' Page 3 of 4 Care and 2-7/8" DIA. - (73,0 mm) 0 Maintenance2 1/4" DIA. The TYCO Series TY-FRB,5.6 K-factor, FACE OF (57,2 mm) Upright (TY313) and Pendent (TY323) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. 3 \ _ ; FLUSH Before closing a fire protection system 3/8±5/16" main control valve for maintenance (9,5±7,9 mm) 7 Al to 'r j I work on the fire protection system i ' that it controls, obtain permission to m-r 1/8" shut down the affected fire protection MOUNTING (3,2 mm) systems from the proper authorities SURFACE and notify all personnel who may be CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) affected by this action. TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an FIGURE 4 escutcheon,clearancee, wole, canh in delayused sprinklertcover SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) a hole, WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 operation in a fire situation. RECESSED ESCUTCHEON The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only 2-7/8" DIA. cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER2-1/4" DIA. _ vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2"(12,7 mm) corrosion must be replaced. 3 - FLUSH Automatic sprinklers must never be / ' 7 I ,7 painted, plated, coated, or other- / Al -------=------'- • wise altered after leaving the factory. I ' �i� 1/8" — Modified sprinklers must be replaced. MOUNTING (3,1 8" Sprinklers that have been exposed to SURFACE corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must - Recessed Escutcheon be replaced. Also, replace any sprin- kler that has a cracked bulb or that has Warrant�/ eon with(specify")finish, P/N(specify") lost liquid from its bulb. (Ref. Installa- 1 Specify: Style 20 Recessed Escutch- tion Section.) For warranty terms and conditions,visit eon with(specify")finish,P/N(specify") The owner is responsible for the www.tyco-fire.com. *Refer to Technical Data Sheet TFP770 inspection,testing,and maintenance of their fire protection system and devices Sprinkler Wrench in compliance with this document, as Ordering Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards Procedure P/N 56-000-6-387 of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order,indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (P/N). with any questions. Sprinkler Assemblies with NPT Automatic sprinkler systems are rec- Thread Connections ommended to be inspected, tested, Specify: Series TY-FRB Upright or and maintained by a qualified Inspec- Pendent (specify) Sprinkler, SIN • tion Service in accordance with local (specify), K=5.6, Quick Response, requirements and/or national codes. (specify) temperature rating, (specify) finish, P/N(specify, refer to Table A). • TFP172 Page 4 of 4 • SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTERC FACTOR COLOR BRASS PLATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT (TY323) 200°F(93°C) Green 5.6 286°F(141°C) Blue 1/2"NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT1,2,3,4 (TY313) 175°F(79°C) Yellow Figures 48 and 5b 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact TYCO Fire Protective Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2"NPT)5/8"Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/N* 77 - XXX - X - XXX • SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2-NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2-NPT) TY323 3 PURE WHITE(RAL9010)`* 155 155°F(68°C) POLYESTER *Use suffix"I"for ISO 7-1 connection; 4 SIGNAL WHITE(RAL9003) 175 175°F 79°C for example,77-370-4-175-I POLYESTER ( ) 5 JET BLACK(RAL9005) 200 200°F(93°C) POLYESTER 9 CHROME PLATED 286 286°F(141°C) **Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION • GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2017 Tyco Fire Products,LP. All rights reserved. t"cc TEFLON is a registered trademark of DuPont ''77 Fire Protection Products Comparative Specification Data Specification A53 NPS 1/0-26 STD,XS and XXS,ANSI Schedules 10 through 160 Covers Seamless and Welded,Black and hot-dipped galvanized nominal(average)wall pipe for coiling,bending,flanging and Scope other special purposes and is suitable for welding.Continuous-Welded pipe is not intended for flanging.Purpose for which pipe is intended should be stated on the order Kinds of Steel Permitted Open-hearth for Pipe Material Basic-Oxygen Electric-Furnace Sets standards for coating of pipe with zinc inside and outside by the hot-dipped process.Weight of coating must not average Hot-Dipped Galvanized less than 1.5 oz per square foot and not less than 1.6 oz per sq foot Permissible Variations in The minimum wall thickness at any point shall not be more than 12.5%under the normal wall thickness specified Wall Thickness CMax% Mn Max% PMax% SMax% Seamless or ERW Chemical Requirements Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Continuous Weld - - 0.06 0.06 Seamless and Electric resistance-welded Tensile Requirements Grade A Grade B Tensile Strength,Min psi 45,000 48,000 60,000 Yield Strength,Min psi 25,000 30,000 35,000 Hydrostatic inspection test procedures for plain end and threaded and coupled pipe are specified.Hydrostatic pressure shall be Hydrostatic Testing maintained for not less than 5 seconds for all sizes of seamless and electric resistance weld pipe Permissible Variations in Plus or Minus 10% Weight per Foot Outside Diameter at any point shall not vary from standard specified more than- Permissible Variations in For NPS 1 1/2 and Smaller Sizes For NPS 2 and Larger Sizes Outside Diameter 1/64"over 1/32"under 1%over 1%under Tensile Test-Transverse required on ERW for NPS 8 and larger Banding Test(Cold)-STD and XS-NPS 2 and under XXS-NPS 1 1/4 and under Mechanical Tests Degree of Bend Diameter of Mandrel Specified For Normal A53 Uses 90 12 x nom dia of pipe • For Close Coiling 180 8 x nom dia of pipe Flattening Test-NPS 2 and larger STD and XS.(Not required for XXS Pipe) Seamless and Electric-Resistance-Welded Bending,flattening,tensile on one length of pipe from each lot of 500 lengths or less of a size Number of Tests Required Continuous-Weld-Bending,Flattening,Tensile NPS 1 1/2 or smaller NPS 2&Larger one/25 long one/50 tons Standard Weight Single Random-15'-22'may be jointers.If plain ends 5%may be 12'-16' Double Random-Shortest Length 22',minimum average for order 35' Lengths Extra Strong&Double Extra Strong Single Random-12'-22'.5%may be 6'-12' Double Random-(XS and lighter)-Shortest Length 22".Minimum average for order 35' Lengths longer than since random with wall thinness heaver than XS subject to negotiation Rolled,Stamped,or Stenciled(Mfgr's option) Required Markings on Name or brand of manufacturer Each Length (On tags attached to each Kind of pipe that is,Continuous Welded,Electric-Resistance-Welded A,Electric-Resistance-Weeded B,Seamless A;or bundle in case of bundled Seamless B:XS for double extra strong pipe) ASTM A 53 Length of Pipe Couplings-Applied handling tight.Couplings 2"and smaller,straight tapped other sizes type Thread Protection-Applied to pipe 4"and larger General Installation End Finish(Unless otherwise specified)-STD or XS or wall thickness less than 0.500 in.(Excluding XXS);plain end beveled.All XXS and wall thicknesses over 0.500 in.Plain end square cut. NOTE:This information is from ASTM Standards. Please refer to the specific Standard or Specification for complete details • Comparative Specification Data Specification A135 NPS 1/4-30",Schedules 10,40 and XL THD Lightwall Covers two grades of electric-resistance welded steel pipe.Grade A is adapted for flanging and bending and is suitable for 4110Scope welding.Purpose for which pipe is intended should be stated on order Kinds of Steel Permitted Open-hearth for Pipe Material Basic Oxygen Electric-Furnace Permissible Variations in The minimum wall thickness at any point shall not be more than 12.5%under the normal wall thickness specified.Threadable, Wall Thickness lightwall(XL)must meet manufacturers minimums. CMax% M_ nMax% PMax% SMax% Chemical Requirements Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Grade A Grade B Tensile Strength,Min psi 48,000 60,000 Yield Strength,Min psi 30,000 35,000 Hydrostatic inspection test procedures for plain end and threaded are specified.Hydrostatic pressure shall be maintained for not Hydrostatic Testing less than 5 seconds for all sizes of electric resistance weld pipe.Non-Destructive electric test should be in accordance with practices E213,method E273 or proactive E213 Permissible Variations in Plus or Minus 10%Schedule 10 Weight per Foot Plus 10%minus 3 1/2%Schedule 40 Permissible Variations in Plus or Minus 1% Outside Diameter Mechanical Tests Tensile Test-Transverse returned on pipe NPS 8 and larger Specified Flattening Test-Three steps required with weld located 8"or 90*from the line of direction of force required Number of Tests Required Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style Lengths Pipe shall be furnished in 38"with a minimum of 20 ft.Pipe furnished to schedule 10 shall be in a specified length between 15 and 22 ft. Required Markings on Rolled,Stamped,or Stenciled(Mfgr's option) Each Length Name or brand of manufacturer (On tags attached to each Kind of pipe that is,Electric-Resistance-Welded A,Electric-Welded B,same schedule wall thickness,schedule 10 or 40,NL 0 bundle in case of bundled ASTM A135 pipe) Length of Pipe General Information End Finish may be plain end beveled or plain end square cut • NOTE: This information is from ASTM Standards. Please refer to the specific Standard or Specification for complete details Comparative Specification Data Specification A795 NPS 1/2-10"Schedule 10 and Schedule 40 Scope Covers Seamless and welded,black and hot-dipped galvanized nominal wall pipe for coiling,bending,flanging and is suitable for welding.Pipe ordered for this specification is intended to be used in fire protection systems Open-hearth Kinds of Steel Permitted Basic Oxygen for Pipe Material Electric-Furnace Sets standards for coating of pipe with zinc inside and outside by the hot-dipped process.Weight of coating must not average Hot Dipped Galvanized less than 1.5 oz per square foot and not less than 1.6 oz per sq foot Permissible Variations in The minimum wall thickness at any point shall not be more than 12.5%under the normal wall thickness. Wall Thickness C Max% Mn Max% P Max% S Max% Seamless or ERW Chemical Requirements Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Continuous Weld - - 0.06 0.06 Hydrostatic inspection test procedures for plain end and threaded are specified.Hydrostatic pressure shall be maintained for not Hydrostatic Testing less than 5 seconds for all sizes of seamless and electric resistance weld pipe. Non destructive electric test in accordance with practices E213 or E309 Permissible Variations in Plus or Minus 5% Weight per Foot Outside Diameter at any point shall not vary from standard specified more than- Permissible Variations in For NPS 1 1/2 and Smaller Sizes For NPS 2 and Larger Sizes Outside Diameter 1/64"over 1/32"under 1%over 1%under Number of Tests Flattening-Tests are to be performed on electric-resistance welded pipe,and furnace welded pipe. Required Lengths Unless specified,pipe shall be furnished on single random lengths of 16 to 22 ft. Rolled,Stamped,or Stenciled(Mfgr's option) Required Markings on Name or brand of manufacturer Each Length (On tags attached to each Electric-Resistance-Welded A,Electric-Resistance-Weeded B,Seamless A bundle in case of bundled Seamless B,Grade A or B for type E or S pipe,wall thickness schedule ASTM A795,the letters NHII Not hydrostatically tested pipe) Length of Pipe General Installation End finish may be plain end beveled or plain end square cut 1111 NOTE: This information is from ASTM Standards. Please refer to the specific Standard or Specification for complete details S t: � U� C ` ., �.. ., ` .. 0'1' r � � " vds LPCB VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS l a STYLES 920 AND 920N ® :Is Victaulic Mechanical-T Outlet provides a direct branch connection at any location a hole can v ,y, • '""` be cut in pipe.The hole is cut oversize to receive a"holefinder" locating collar which secures - the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and4Iy size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order. Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE)pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E"EPDM EPDM(Green color code).Temperature range-30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range-20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para 40 Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC.t.aUIi�. REV tv7 C CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N • DIMENSIONS Style Max.Work Approx. Size No. Pressure Dimensions Weight Each 'a Run x Branch Female Nominal Size rf x w v ;2 RInches or psi JfIJ? Inches Inches Inches Inches Inches Lbs. Lbs. Y - t Z-' . m 920N kPa3x-0.00 mm minmm mm. umin [i• t 71 2 x 1(a)° 1 920N 500 1.50 2.00 2.53 _ 1.61 5.35 2.75 3.1 Immo. V 50 15 3450 38.1 51 64 41 136 70 1.5 nr �� ren V " '4(a)° 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 i 20 3450 38.1 50 64 41 136 70 1.5 T 1(a)° 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 + I v-�I 25 920N 3450 38.1 47 64 41 136 70 1.4 � 11/4(a)tali 9209 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2(a)to. 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 ,r Y - 4 Z 21/2 h(a)5°, 920N 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 ? 65 x 15 3450 38.1 56 70 46 143 70 1.4 3/a(a)8° 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 V no rir 20 3450 38.1 55 70 46 143 70 1.4 l'- 4- 1(0)§° 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 � � J 25 3450 38.1 52 70 46 70 1.4 y I\ I 1 Ya t(a)°j 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 �--1 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 11/2t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 FEMALE THREADED OUTLET 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 7. k(a) { 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at4(a) 92013 any location where a hole can be cut 20 2065 38.1 56 70 57 164 81 1.8 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 in the pipe 1(a) 920N 300 150 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides •11/43(a)°! 9209 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 2 3450 44.5 58 76 84 49 160 76 1.6 1.5 11/2(a)0 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 Y(a)❑ 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4(a)° 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe;also available for use 20 3450 38.1 63 78 58 156 70 1.6 with HDPE pipe 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 _ 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15 mm 11/4(a)t°= 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4"/200 x 100mm 32(b) I 3450 44.5 65 83 90 58 156 76 1.8 1.8 11/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)° 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 503450 63.5 70 89 90 58 172 99 2.3 2.1 I 31/2 2 500 2.50 3.00 j 3.75 2.44 6.72 3.88 _ 3.8 90 x 50 920N 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be m Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. # Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/"BSPT clearly on order. §Vds approved for fire protection services °LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. ii • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iictaullic, +102 2 REVM CARSON STEEL PIPE-HOLE CUT PRODUCTS 11.02 4110 STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Unx ire ' Vr# V �- .... Fernale NominalSize 920 Diameter `r* Thd.- Gm W y- �Y Z Inches ar ars 1613 Inches Inches Inches h r ! p,, -0.00 " 'mm +m mm `;mm mm �s.. , s 4 TABLE CONTINUED FROM PAGE 2 �'� 4 (a)0 500 1.50 3.03 3.56 _ 2.69 7.01 2.75 3.7 sir �� rny r 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 -- 3/a(a) 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 �� ? 20 3450 38.1 76 90 68 178 70 8 W .ice 1(a)❑ 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 I 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 11/4(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 Y(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 x Y z- . 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 R 2(a)to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 PR50 ) 3450 63.5 83 102 102 68 178 99 2.3 2.1 V �rn � urs T t. 2'/(a)t 1 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 I 3450 69.9 73 102 102 68 186 118 2.6 2.3 i ��-40 •�4_ 76.1 mm 920 500 2.759. 73 102 2.69 71864 118 _ 2.9 y \-1_..i...1 3450 69.9 73 102 68 186 118 2.9 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET -- -- - 1 1/4(a)9 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 108.0 x 32 920N _ 3450 44.5 78 96 67 194 78 2.3 11/2(3)9 920N 500 2.00 3.28 4.00 _ 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 102 1.9 • 76.1 m 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1/z(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 i 2(a)t ' 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe;also available for use 2' (a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 8.0 • Sizes from 2 x '/2'/50 x 15 mm 3450 69.9 95 21 80 246 118 3.6 through 8 x 4"/200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 _ 3.17 8.00 3.88 8.0 133.0 x50 1 920N 3450 63.5 95 114 81 203 99 3.6 3500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 920 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic' Jv 7,4 i CARBON STEEL,PIPE-HOLE CUT PRODUCTS 1 1.02 -Met,::1 "funic Rotted Brc-%,..-,-.11 Outlets STYLES 920 AND 920N • DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each MnxOrancb VtIt lit Fe n*.r.' Nominal WO tl Thd Giv. W Y Z ' Inches of arse liesinches Inches mches mches Inches os., 4 Y -• 1 Z `*'•*B2ON kPa nun. ram xr !T1 mm rnm kg kg _ TABLE CONTINUED FROM PAGE 3 �� 1 r/z t 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 V 139.7 x 920N - - fo � on Ir�11 40 3450 50.8 96 114 84 209 83 3.2 -13 414P W+ 1--1.2 2 t 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 T 50 920N 3450 63.5 95 114 84 209 99 4.1 l 6 11/4(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) ! 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 11(a)I'm 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) ; 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)ta '..... 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 4 Y r Z-.. 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2'/2 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 920 3450 69.9 110 130 130 94 267 118 3.8 3.4 vt PIN u1.l 1- 10111-oMth t 500 2.75 4.15 - 5.21 3.69 10.51 4.63 8.4 T 761 mm• 920 3450 69.9 105 132 94 267 118 3.8 � 3(a)t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 , 3450 88.9 110 140 130 94 267 135 4.5 3.8 11-�^Il 4(a)to i 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 920 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET -_.-."...�.._` 1/(a) I 500 2.00 411421 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 112 130 92 239 83 3.5 2(a) i920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut .1 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 76.1 mm 920 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0 mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa ..Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with HDPE pipe t Center of run to end of fitting. • Sizes from 2 x 1/2"/50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4'/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. "- - • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.m 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulac'. i) 02 4 CARBON STEEL PIPE-HOLE CUT !RODUC FS 11.02 t '' ii - .0 . " b -incl . 1,: • STYLES 920 AND 920N • DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each 41UatNomin'Size 420 hes mm , 92 ► . 0 m Inni TABLE CONTINUED FROM PAGE 4 �� 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 x 920N - - ��� 1i1' Ifs] 25 j 3450 38.1 99 116 96 237 70 3.6 /-- 13 a 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 _ �ITLP w 32 3450 44.5 113 130 96 237 83 3.8 11/2(a)t❑1: 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t . 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 4 Y < Z-. _ 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a)to 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 PR 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 ,_ , V u5l 10u T � iis 4(a)to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 x 2(a)t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 V\4/, .1 .-_,1. 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 21/2(a)t I 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 761 mm a 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 889 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 IIIin the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 i'"Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal * Center of run to end of fitting. • Request Publication 11.03 for 8 Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. For 76.1 mm threaded outlet,specify 21/a BSPT clearly on order. on steel pipe;also available for use (b) with HDPE pipe §Vds approved for fire protection services o LPCB approved for fire protection services • Sizes from 2 x 1/2"/50 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4'/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to Fach other to achieve cross connections. • .. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtSIUIIC' REV M ;:,OE 9 CARBON STEEL PIPE- 1CI_E:CUT PRODUCTS 11.02 . iii ` .1?d" l,a9 I .r '; land 1»5£,31 \ t ; , STYLES 920 AND 920N • FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-T®fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. C) Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for Cv/lc Values: AP = Q2 Where: �P = Q2 Where: O_ C2 Q=Row(GPM) K s1 IIIMII �1` AP=Pressure Drop(psi) C)=Flow(m/h) �� Q = C x AP=Pressure Drop(bar) DP C =Flow Coefficient Q = K x 4P K =Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213,Sec.16) OUTLET SIZE (C=120)t FT C„/K„Values NOmNAC UA!DIAMETER fS Inlmra inhtUO L _r. GROOyED Tlf.READED MOVED .__. THREADED.. 1 0.840 11 15 21.3 i 2 - 9.4 3A 1.050 4 16 20 26.7 13.7 1 1.315 21 25 33.7 8 1.8 1/ 1.660 50 48 5 Y2 6 32 42.7 I 42.9 41.1 • 1%z 1.900 1 53 53 40 98.3 11 3 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10 1/296 89.1 2.875 119 150 65z 73.0 20 12 1/2 102 128.5 3.00061 76.1 mm 76.1 1 16* 138.1 3.500 249 237 80 88.9 14 5 1/2213.4 203.1 4 ( 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. ., • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ict`c#UlIC CARBON STEEL.PiF,L- HOLE CUT PRQDUt.TS 11.02 0 STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. . Approval Agency Run Size Outlet Size Pipe Rated Working Pressures-psi/kPa AQtu$k Nominal 0 t. 3 )ne „UEit ... FM - , Wei' (Style 82 .4. 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875-4.500 All OF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 _ _ 145 200 219.1 2755 1000 8 8.625 3,4 10 300 250 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. • SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100-200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. I The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100mm, 5"/125mm,6"/150mm and 8"/200 mm diameter pipe.The Style 931 comes with a 21/2"/65mm grooved outlet. II its."t I The drill motor is an electric motor with ground fault circuit interrupter(GFCI)in accordance with 3 safety codes. For more information, refer to publication 24.01. I it, , 411) .,,. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. •ctaul.c RE'a ?;< 11,02 7 lylecteanicalrie bolted x th STYLES 920 AND 920N • INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • • For complete contact information,visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 iCtaula VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. _ _----_•